Attch_9b_-_Sample_Project_TO_Concept_Design.pdf
PDF 3 MB Posted
- Attached to
- VELA MACC Federal contract opportunity
- Solicitation number
- FA4610-17-R-0002
About this file
This pre-solicitation notice announces an upcoming solicitation for the Vandenberg AFB, Edwards AFB, and Los Angeles AFB Multiple Award Construction Contract (VELA MACC). The Air Force intends to issue solicitation FA4610-17-R-0002 on or around August 21, 2017 for indefinite-delivery, indefinite-quantity construction contracts with a base period and four one-year options. The NAICS code is 236220 and size standard is $36.5M. The award is contemplated as an 8(a) small business set-aside for participants headquartered in California. The VELA MACC will provide construction services including maintenance, repair, and new construction of buildings, facilities, and base infrastructure using design-build and bid-build approaches. Interested parties are advised to monitor FedBizOpps for release of the solicitation and any amendments.
Attch 9b - Sample Project TO Concept Design
View the file
Other files for this federal contract opportunity
Show all 44
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
D A
TE
D
ES
C
RI
PT
IO
N
O F
RE
V
IS
IO
N
SY
M
BO
L
PROJECT #
SHEET #
DRAWING #
D A
TE
OF
SC
A
LE
D
RA
W
IN
G T
ITL
E
PR
O
JE
C
T
TIT
LE
D
RA
W
N
RE
V
IE
W
ED
D
ES
IG
N
ED
F O
R
O
F F
I C
I A
L
U
S E
O
N L
Y
I N
F O
R M
A T
I O
N
S
A F
E G
U A
R D
I N
G
I
R
Q
U I R
D
T h e i n f o r m a t i o n c o n t a i n e d o n t h i s d r a w i n g s h a l l r e m a i n u n d e r t h e c o n t r o l o f t h e o r i g i n a t i n g r e q u e s t e r o r a g e n c y o r i t s s u c c e s s o r i n f u n c t i o n a t a l l t i m e s n f o r m a t i o n s a f e g u a r d i n g i s t h e r e s p o n s i b i l i t y o f t h e i n d i v i d u a l a g e n c y c o m p a n y r e q u e s t i n g t h e d a t a a n d t a k i n g o r i g i n a l p o s s e s s i o n o f t h i s d r a w i n g e l e a s e d i s c l o s u r e o f d a t a t o a n y p a r t y b e y o n d t h e o r i g i n a l r e q u e s t a n d i n t e n d e d u s e i s p r o h i b i t e d o p u b l i c p u b l i c a t i o n o f t h e d a t a b y a n y m e a n s o r a n a l y s e s t h e r e o f i s a u t h o r i z e
U p o n c o m p l e t i o n o f t h e u s e o f t h e d a t a c o n t a i n e d o n t h i s d r a w i n g t h e d r a w i n g m u s t b e r e t u r n e d o r d e s t r o y e i r e c t a n y q u e s t i o n s t o t h e
E n g i n e e r i n g
S u p p o r t
E l e m e n t
C
E S
C
E C
B a t
I n f o r m a t i o n s a f e g u a r d i n g r e q u i r e m e n t s a r e p e r
A
F M
A N
A
F I
D g a n d
E x e c u t i v e
O r d e r w h e n a p p l i c a b l e
D O
N O
T D
U
PL
IC
A
TE
T
H
IS
D R
A W
IN
G
O
R T
H E
D A
TA
C
O N
TA
IN
ED
O
N
IT
09-1253
G001
A pr
A S
N O
TE
D
KR
G
KR
G
KR
G
RE
PA
IR
IN
TE
RI
O R/
EX
TE
RI
O
R O
F D
O
RM
, B
LD
G
SI
TE
P
LA
N , B
LD
G
SITE PLAN
SCALE: 1/16" = 1'-0"
NORTH
PROJECT
NORTH
TRUE
TYPICAL DEMOLITION NOTES 45
A. CAREFUL COORDINATION IS NEEDED WITH CONSTRUCTION DOCUMENTS
DESCRIBING NEW WORK TO ENSURE THAT BUILDING ELEMENTS INTENDED TO
REMAIN ARE ADEQUATELY PROTECTED AND MAINTAINED. ADDITIONAL
DEMOLITION MAY BE REQUIRED BASED ON INFORMATION FOUND ON OTHER
DRAWINGS.
B. ALL DEMOLITION SHALL BE EXECUTED AS NOT TO DAMAGE (E) ELEMENTS,
INCLUDING LANDSCAPING AND IRRIGATION SYSTEMS WHICH ARE TO REMAIN.
C. EXISTING ELEMENTS TO REMAIN SHALL BE PROTECTED TO THE FULLEST EXTENT
POSSIBLE. ALL ELEMENTS OF THE STRUCTURE THAT ARE TO REMAIN & WHICH ARE
DAMAGED DURING DEMOLITION OPERATIONS SHALL BE REPLACED BY THE
CONTRACTOR AT NO COST TO THE GOVERNMENT.
D. ALL WORK NOT SPECIFICALLY MENTIONED THAT INTERFERES WITH NEW
CONSTRUCTION SHALL BE DEMOLISHED IN A MANNER THAT PROVIDES PROPER
INTERFACE WITH NEW CONSTRUCTION. PATCH AND REPAIR AS NECESSARY.
E. THE CONTRACTOR SHALL ENACT ALL MEASURES NECESSARY TO PROTECT (E)
BUILDING ELEMENTS TO REMAIN. PROMPTLY REPAIR DAMAGE DURING
DEMOLITION TO MATERIALS AND OTHER EXISTING BUILDING ELEMENTS TO REMAIN.
F. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS PRIOR TO BEGINNING WORK.
COMMENCEMENT OF WORK INDICATES ACCEPTANCE BY CONTRACTOR OF
EXISTING CONDITIONS.
G. CONTRACTOR SHALL FIELD VERIFY AND PROTECT ALL (E) UTILITIES AS DIRECTED BY
CONTRACT PRIOR TO STARTING ANY WORK.
H. PROPER MEASURES SHALL BE TAKEN TO CAP, DISCONNECT OR RELOCATE ANY
EXISTING WATER, GAS, ELECTRICAL, WASTE OR COMMUNICATION LINES AS NEEDED
TO SUPPORT NEW CONSTRUCTION.
I. NOTIFY CONTRACTING OFFICER IF ANY EXISTING UTILITY SHALL INTERFERE WITH
CONSTRUCTION. INSPECT, REPAIR AND VERIFY THAT NO OBSTRUCTIONS EXIST IN
ALL UTILITY CHASES & WALLS FOR NEW UTILITY INSTALLATION.
J. PROTECT AND MAINTAIN ALL (E) LANDSCAPE AREAS INSIDE OF INDICATED AREA
OF WORK. ENSURE ALL IRRIGATION IS OPERATING CORRECTLY AND PROVIDE ANY
NECESSARY REPAIRS PRIOR TO COMPLETION OF PROJECT.
K. CONTRACTOR SHALL PROVIDE ACCESS TO ALL AREAS OUTSIDE OF AREA OF WORK
AS OTHER BUILDINGS SHALL BE OCCUPIED DURING CONSTRUCTION.
L. CONTRACTOR SHALL COORDINATE WITH CONTRACTING OFFICER AND
INSTALLATION PROJECT MANAGER TO IDENTIFY AREA FOR PROJECT LAYDOWN.
M. CONTRACTOR SHALL ADEQUATELY PROTECT LAYDOWN AREA, ALL WASTE
MANAGEMENT ACTIVITIES AND AREA OF CONSTRUCTION AS ADJACENT FACILITIES
WILL BE OCCUPIED DURING CONSTRUCTION.
N. PRIOR TO COMPLETING CONSTRUCTION, CONTRACTOR SHALL CLEAN THE SITE OF
ALL CONSTRUCTION DEBRIS, SPILLAGE AND DAMAGE TO ALL SITE ELEMENTS TO
INCLUDE WALKWAYS, PARKING LOTS, LANDSCAPING AND ADJACENT FACILITIES.
O. CONTRACTOR SHALL FIELD VERIFY LOCATION AND PROTECT ALL DRAIN INLETS IN
AREA OF WORK AND THOSE AFFECTED BY AREA OF WORK (i.e. WITHIN DRAINAGE
AREA); COORDINATE EFFORT WITH 30 CES/CEAN TO CONFIRM REQUIREMENTS
AND ENSURE COMPLIANCE WITH INSTALLATION, COUNTY AND STATE
REQUIREMENTS.
P. REPLACE ALL EXISTING EXTERIOR AND INTERIOR SIGNAGE TYPICAL THROUGHOUT
FACILITY. ALL NEW SIGNAGE TO MEET STANDARDS AS OUTLINED IN UFC 3-120-01
AIR FORCE SIGN STANDARD & INSTALLATION FACILITIES EXCELLENCE STANDARDS.
SITE PLAN NOTES 35
BU
IL
D
IN
G
BU
IL
D
IN
G
SO
UT
H D
A
KO
TA
A
V
EN
UE
N O
T
IN
C O
N
TR
A C
T
N O
T
IN
C O
N
TR
A C
T
SHEET INDEX 11
G001 GENERAL INFORMATION, OVERALL SITE PLAN
AD101 TYPICAL MODULE DEMOLITION PLAN, FIRST & SECOND
FLOOR DEMOLITION PLANS
AD102 THIRD FLOOR & ROOF DEMOLITION PLANS
AD201 EXTERIOR ELEVATIONS, DEMOLITION
A101 TYPICAL MODULE FLOOR PLAN, FIRST & SECOND
FLOOR PLANS
A102 THIRD FLOOR & ROOF PLANS
A201 EXTERIOR ELEVATIONS
A301 BUILDING SECTIONS
E101 ELECTRICAL FLOOR PLANS
1. APPROXIMATE AREA OF WORK AT (E) BUILDING SITE; FINAL BOUNDARY TO BE
COORDINATED WITH DORM MANAGER.
2. APPROXIMATE LOCATION OF (N) UTILITY AREA ENCLOSURE (WALL AND GATE);
SEE FIRST FLOOR PLAN FOR ADDITIONAL INFORMATION REGARDING WALL
LOCATION AND (N) CONCRETE SLAB.
3. REMOVE (E) TRANSFORMER SCREEN WALL ALONG WITH (E) CONCRETE FOOTING.
4. (E) TRANSFORMER TO REMAIN TYPICAL; PROTECT FROM DAMAGE AS NECESSARY.
5. (E) ELECTRICAL CABINET TO REMAIN TYPICAL; CABINET TO BE CLEANED AND
PAINTED TO MATCH ADJACENT BUILDING; PROVIDE ENERGY MONITORING
EQUIPMENT AS DIRECTED BY INSTALLATION ENERGY MANAGER (30 CES/CEAOI).
6. (E) GAS MAIN REGULATOR AND METER TO REMAIN TYPICAL; PROVIDE ENERGY
MONITORING EQUIPMENT AS DIRECTED BY INSTALLATION ENERGY MANAGER (30
CES/CEAOI).
7. (E) LOW WALL TYPICAL AT (2) LOCATIONS; PATCH, REPAIR AND PAINT ALL
EXTERIOR PLASTER SURFACES; REPAIR ALL DAMAGED GROUT JOINTS AT WALL
CAP AS NEEDED.
8. CLEAN (POWER WASH) ALL CONCRETE WALKWAYS AND PATIOS INSIDE OF
INDICATED AREA OF WORK.
9. FIELD VERIFY ASSUMED BACKFLOW PREVENTER FOR B13323 AND REPLACE; IF THIS
IS NOT THE CORRECT BACKFLOW PREVENTER, FIND CORRECT BACKFLOW
PREVENTER AND REPLACE; PROVIDE SPLIT FACED CMU SCREEN WALL AND
CONCRETE PAD AS REQUIRED IN FACILITIES EXCELLENCE STANDARDS.
10. NEW CONCRETE SIDEWALK TO MATCH EXISTING.
11. VERIFY CONDITION OF WOOD AND REPLACE IF NEEDED
12. REMOVE SITE SIGNS INCLUDING ELECTRICAL AND FOOTING..
A. DESIGN BUILDING ENVELOPE AND HVAC SYSTEM TO COMPLY WITH ETL 04-3 (CHG
1): DESIGN CRITERIA FOR PREVENTION OF MOLD IN AIR FORCE FACILITIES
B. SEAL ALL OPENING AROUND DOORS AND WINDOW, LINTELS, UTILITY PENETRATIONS,
SEAMS IN VAPOR RETARDERS AND AIR BARRIERS, INTERSECTIONS OF WALLS, ROOFS,
FLOORS AND FOUNDATION WALLS.
C. INSTALL NON-PERMEABLE SILL GASKETS BETWEEN FLOORS AND THE BOTTOM PLATE
OF EXTERIOR WALLS (i.e. FILL IN PANELS).
D. FLASH ALL WINDOWS AND EXTERIOR DOORS WITH CORROSION-RESISTANT FLASHING
TO PREVENT WATER INTRUSION INTO THE WALL CAVITY.
E. PROVIDE WINDOWS AND DOOR FRAMES THAT MINIMIZE THERMAL BRIDGING.
F. SUPPLY VENTILATION AIR TO SATISFY ASHRAE 62-2001 FOR THE NUMBER OF
OCCUPANTS OR AS REQUIRED TO MEET THE CONTINUOUS EXHAUST AIR
REQUIREMENT PLUS 15% FOR PRESSURIZATION, WHICHEVER IS LARGER.
G. FILTER VENTILATION AIR BEFORE IT ENTERS AN AIR HANDLER, HEAT RECOVERY
EQUIPMENT OR PRE-CONDITIONING EQUIPMENT. USE EXTENDED MEDIA FILTERS WITH
A MERV OF 7 OR GREATER IN ACCORDANCE WITH ASHRAE 52.2-1999.
H. SUFFICIENTLY SIZED, SAFE ACCESS MUST BE PROVIDED FOR THE MAINTENANCE OF
VALVES, VAV BOXES, DAMPERS, CONTROLS AND OTHER HVAC COMPONENTS.
I. THE HVAC SYSTEM MUST EMPLOY SEPARATE, DEDICATED, CENTRAL VENTILATION AIR
CONSTAINT-VOLUME SUPPLY SYSTEMS THAT SUPPLY DEHUMIDIFIED AND TEMPERED
100% OUTSIDE AIR TO ALL OCCUPIED SPACES.
J. FACILITY CENTRAL VENTILATION AIR SUPPLY SYSTEMS MUST NOT BE SUBJECT TO
INTERMEDIATE SEASON SHUTDOWN.
K. VENTILATION SYSTEMS MUST BE DESIGNED TO MINIMIZE THE TRANSMISSION OF
SOUND BETWEEN QUARTERS.
L. A CENTRAL DUCTED BATHROOM EXHAUST SYSTEM WILL BE USED INSTEAD OF
INDIVIDUAL EXHAUST FANS FOR EACH SPACE. THE EXHAUST SYSTEM MUST RUN
CONTINUOUSLY AND BE INTERLOCKED WITH THE BUILDING SUPPLY AIR SYSTEM.
M. THE EXHAUST DUCT FOR EACH SPACE SHALL HAVE A MANUAL VOLUME DAMPER
ACCESSIBLE FROM THE SPACE FOR PROPER BALANCING.
N. INSTALL AN EXHAUST GRILLE CONSTRUCTED OF CORROSION-RESISTANT MATERIAL
JUST OUTSIDE EACH SHOWER STALL.
O. EXHAUST FROM MOISTURE-PRODUCING EQUIPMENT (i.e. CLOTHES DRYERS) SHALL BE
VENTED TO THE EXTERIOR.
P. WITHIN BATHROOMS, THE SUBSTRATE BENEATH CERAMIC TILE, PLASTIC TILE OR
PLASTIC FINISHED WALL PANELS IN AREAS EXPOSED TO WATER (e.g. TUB AND
SHOWER ENCLOSURES) MUST BE MADE OF CEMENT, FIBER CEMENT OR COMPOSITE
MATERIALS MANUFACTURED SPECIFICALLY FOR USE IN HIGH-MOISTURE LOCATIONS.
Q. HVAC SYSTEMS SHALL BE COMMISSIONED IN ACCORDANCE WITH UFGS 15995 TO
VERIFY AND DOCUMENT THAT ACTUAL PERFORMANCE OF THE SYSTEMS HAS MET
DESIGN REQUIREMENTS.
HUMIDITY/HVAC REQUIREMENTS 15
ENTIRE RENOVATION EFFORT TO MEET MINIMUM STANDARDS AS OUTLINED IN THE
FOLLOWING REFERENCES:
- VANDENBERG AFB FACILITIES EXCELLENCE STANDARDS
- STANDARD INSTALLATION SPECIFICATIONS
- UFC 3-110-03 ROOFING
- UFC 3-120-01 AIR FORCE SIGN STANDARD
- UFC 3-120-10 INTERIOR DESIGN
- UFC 3-400-01 ENERGY CONSERVATION
- UFC 3-401-01FA UTILITY MONITORING AND CONTROL SYSTEMS
- UFC 3-410-01FA HEATING, VENTILATING, AND AIR CONDITIONING
- UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS
- UFC 4-021-01DESIGN & OM: MASS NOTIFICATION SYSTEMS
- UNACCOMPANIED HOUSING GUIDE, USAF
TYPICAL STANDARDS 25
A. FIRE PROTECTION SYSTEMS MUST CONFORM TO FIRE PROTECTION FOR FACILITIES
ENGINEERING, DESIGN AND CONSTRUCTION AND TO NATIONAL FIRE PROTECTION
ASSOCIATION (NFPA) FIRE CODES
B. BASED ON THE INTERNATIONAL BUILDING CODE (IBC), A DORMITORY MODULE IS
CLASSIFIED AS AN EFFICIENCY APARTMENT WITH AN R-2 OCCUPANCY.
C. BASED ON THE LIFE SAFETY CODE, THIS OCCUPANCY IS CLASSIFIED AS AN
APARTMENT BUILDING. PROVISIONS FOR LIFE SAFETY MUST CONFORM TO THE
REQUIREMENTS FOUND IN THE LATEST EDITION OF NFPA 101, LIFE SAFETY CODE.
D. INSTALL FIRE SPRINKLER PROTECTION THROUGHOUT FACILITY AS REQUIRED TO MEET
NFPA STANDARDS
E. INSTALL FIRE SUPPRESSION SYSTEM OVER RANGE IN HOOD TYPICAL
F. ALL NEW DORMITORIES AND MAJOR DORMITORY RENOVATION PROJECTS MUST BE
PROTECTED THROUGHOUT BY AN APPROVED SUPERVISED AUTOMATIC SPRINKLER
SYSTEM INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS SPECIFIED IN NFPA 13,
INSTALLATION OF SPRINKLER SYSTEMS, OR 13R, SPRINKLER SYSTEMS IN RESIDENTIAL
OCCUPANCIES UP TO AND INCLUDING FOUR STORIES IN HEIGHT, AS APPROPRIATE
AND OTHER FIRE CODES REFERENCED THEREIN.
G. SPRINKLER WATER SUPPLIES FOR SYSTEMS DESIGNED IN ACCORDANCE WITH NFPA 13
SHALL COMPLY WITH FIRE PROTECTION FOR FACILITIES ENGINEERING, DESIGN AND
CONSTRUCTION.
H. ENSURE ADEQUATE SPACE IS INCLUDED IN THE MECHANICAL ROOM FOR THE
SPRINKLER RISER OR, IF NO MECHANICAL ROOM IS IN THE PROJECT, A SPRINKLER
RISER CLOSET WITH ADEQUATE SPACE TO SERVICE THE RISER.
I. FIRE SPRINKLER HEADS SHALL BE RECESSED AS STANDARD DESIGN, WITH AN
EXPOSED HEAD WITH PROTECTIVE CAGE ACCEPTABLE IN UTILITY OR SERVICE
LOCATIONS.
J. FIRE DETECTION/INTERNAL ALARM AND REPORTING SYSTEM SHALL CONFORM TO
THE LATEST EDITION OF NFPA 72, NATIONAL FIRE ALARM CODE.
K. NEW FIRE ALARM CONTROL PANELS SHALL BE COMBINED WITH A MASS
NOTIFICATION SYSTEM IN CONFORMANCE WITH UFC 4-021-01DESIGN & OM: MASS
NOTIFICATION SYSTEMS
L. EACH DORMITORY LIVING/BEDROOM AREA, SHARED SOCIAL SPACES AND DORM
MANAGER OFFICE MUST BE PROVIDED WITH AN APPROVED SINGLE STATION
SMOKE/HEAT DETECTOR POWERED FROM THE BUILDING ELECTRICAL SYSTEM.
M. ALL LIVING AREAS, MODULES AND SUPPORT AREAS (DORMITORY MANAGERS
OFFICE, MECHANICAL SPACE) SHALL BE CLEARLY IDENTIFIED ON AN ADDRESSABLE
PANEL, BASED ON LOCAL REQUIREMENTS.
N. PROVIDE CARBON MONOXIDE DETECTORS IN APPROPRIATE LOCATIONS
THROUGHOUT FACILITY.
FIRE PROTECTION NOTES 13
KEY PLAN 65
13123
13121
0 13
SCALE: NOT TO SCALE
NORTH
PROJECT
BUILDING 13323
NOT IN CONTRACT
BUILDING 13321
AREA OF WORK
FA4610-17-R-0002
Attachement 9b
DNUP DNUP
A
TE
D
ES
C
RI
PT
IO
N
O F
RE
V
IS
IO
N
SY
M
BO
L
PROJECT #
SHEET #
DRAWING #
D A
TE
OF
SC
A
LE
D
RA
W
IN
G T
ITL
E
PR
O
JE
C
T
TIT
LE
D
RA
W
N
RE
V
IE
W
ED
D
ES
IG
N
ED
F O
R
O
F F
I C
I A
L
U
L
Y
I N
F O
R M
A T
I O
N
S
A F
E G
U A
R D
I N
G
Q
U I R e i n f o r m a t i o n c o n t a i n e d o n t h i s d r a w i n g s h a l l r e m a i n u n d e r t h e c o n t r o l o f t h e o r i g i n a t i n g r e q u e s t e r o r a g e n c y o r i t s s u c c e s s o r i n f u n c t i o n a t a l l t i m e f o r m a t i o n s a f e g u a r d i n g i s t h e r e s p o n s i b i l i t y o f t h e i n d i v i d u a l a g e n c y c o m p a n y r e q u e s t i n g t h e d a t a a n d t a k i n g o r i g i n a l p o s s e s s i o n o f t h i s d r a w i n l e a s e d i s c l o s u r e o f d a t a t o a n y p a r t y b e y o n d t h e o r i g i n a l r e q u e s t a n d i n t e n d e d u s e i s p r o h i b i t e p u b l i c p u b l i c a t i o n o f t h e d a t a b y a n y m e a n s o r a n a l y s e s t h e r e o f i s a u t h o r i z e o n c o m p l e t i o n o f t h e u s e o f t h e d a t a c o n t a i n e d o n t h i s d r a w i n g t h e d r a w i n g m u s t b e r e t u r n e d o r d e s t r o y e r e c t a n y q u e s t i o n s t o t h e
E n g i n e e r i n g
S u p p o r t
E l e m e n t
C
E S
C
E C
B a t
I n f o r m a t i o n s a f e g u a r d i n g r e q u i r e m e n t s a r e p e r
A
F M
A N
A
F I
D g a n d
E x e c u t i v e
O r d e r w h e n a p p l i c a b l e
D O
N O
T D
U
PL
IC
A
TE
T
H
IS
D R
A W
IN
G
O
R T
H E
D A
TA
C
O N
TA
IN
ED
O
N
IT
09-1253
AD101
A pr
A S
N O
TE
D
KR
G
KR
G
KR
G
RE
PA
IR
IN
TE
RI
O R/
EX
TE
RI
O
R O
F D
O
RM
, B
LD
G
FI
RS
T
S
EC
O N
D F
LO
O
R D
EM
O
LI
TIO
N P
LA
N
, B
LD
G
TY
PI
C A
L M
O D
UL
E
D
EM
O
LI
TIO
N
P
LA
N
SECOND FLOOR DEMOLITION PLAN, BLDG 13321
SCALE: 1/8" = 1'-0"
DEMOLITION NOTES 15KEY PLAN 65
FIRST FLOOR DEMOLITION PLAN, BLDG 13321
SCALE: 1/8" = 1'-0"
TYPICAL MODULE DEMOLITION FLOOR PLAN (SECOND FLOOR SHOWN)
SCALE: 1/4" = 1'-0"
1. REMOVE ALL CABINETRY, FIXTURES, PLUMBING AND ELECTRICAL TO ALLOW
INSTALLATION OF (N) FIXTURES.
2. REMOVE (E) CLOSET DOORS & ALL HARDWARE, SHELVING & FIXTURES TYPICAL.
3. REMOVE ALL WALLS (SHOWN HATCHED), FINISHES, FLOOR FINISHES, MECHANICAL
EQUIPMENT AND DUCTING, ELECTRICAL CONDUITS, BOXES, WIRING AND FIXTURES,
PLUMBING FIXTURES AND PIPING AND ALL EQUIPMENT TO PREPARE FOR NEW WORK.
WALL STUDS IN WALLS NOT INDICATED TO BE REMOVED MAY REMAIN AT
CONTRACTORS DISCRETION.
4. REMOVE (E) WINDOWS, DOORS, FRAMES, HARDWARE TO PREPARE FOR (N) WORK.
5. REMOVE ALL TOILET ROOM FINISHES, PLUMBING FIXTURES, AND ALL PIPING IN (E)
WALLS. CAP ALL PIPES TO REMAIN FOR RE-USE TO PREPARE FOR NEW WORK.
6. REMOVE (E) CABINETRY OVER (E) WASHER DRYER AREA AND PREPARE AREA TO
ACCEPT (N) WORK.
7. REMOVE EXISTING CABINETRY, RANGE AND STOVE, OVERHEAD VENT, SINK AND
FIXTURES TO PREPARE FOR NEW WORK.
8. REMOVE AND PROPERLY DISPOSE OF EXISTING REFRIGERATOR AS DIRECTED BY
CONTRACTING OFFICER.
9. REMOVE (E) RAIL ON EXTERIOR OF BUILDING AT (E) SLIDING GLASS DOORS AT REAR
OF BUILDING. PATCH ALL HOLES IN EXTERIOR WALL AND PREPARE FOR NEW WORK.
10. ALL HANDRAILS AND GUARDRAILS AT BALCONIES TO BE REPAIRED, CLEANED,
SANDBLASTED AND PAINTED. REMOVE ONLY AS NEEDED FOR REPAIR.
11. POWERWASH ALL CONCRETE FLOOR SURFACES AT BALCONIES, RISERS AND TREADS.
12. REMOVE ALL LIGHT FIXTURES AT EXTERIOR OF BUILDING AND STAIRS. COORDINATE
REMOVAL WITH CONSTRUCTION DRAWINGS FOR REPLACEMENT.
13. REMOVE ALL FLOORING TO INCLUDE BUT NOT LIMITED TO CARPET, VINYL TILE,
CERAMIC TILE AND MASTIC TO CONCRETE SLAB TYPICAL.
14. REMOVE ALL PAINT ON EXPOSED STRUCTURAL STEEL AND METAL FLASHING TO
PREPARE FOR PAINTING.
15. REMOVE EXISTING EXTERIOR BUILDING IDENTIFICATION SIGNAGE TO BE REPLACED
16. REMOVE ALL EXISTING DOORS, HARDWARE AND FRAMES TO BE REPLACED
17. REMOVE ALL (E) CABINETRY, FIXTURES, PLUMBING, ELECTRICAL AND
COMMUNICATIONS LINES TO BE REPLACED TYPICAL.
18. REMOVE ALL EXISTING HVAC EQUIPMENT, PIPING, CIRCULATION PUMPS, CONTROL
PANELS, CONDUITS AND WIRING INSIDE AND OUTSIDE ROOM TO BE REPLACED;
VERIFY WITH INSTALLATION PM IF BOILER AND ASSOCIATED EQUIPMENT REQUIRES
REPLACEMENT PRIOR TO BID (EQUIPMENT MAY BE REPLACED UNDER SEPARATE
EFFORT).
19. REMOVE (E) WINDOW AND LOUVER VENT TO BE REPLACED
20. REMOVE (E) HANDRAIL/GUARDRAIL TO BE REPLACED
21. REMOVE (E) DOORS TO BE REPLACED
22. REMOVE ALL (E) BUILT-UP ROOF, EQUIPMENT NOT USED AND ASSOCIATED
FLASHING/COPING AT THIS AREA TO BE REPLACED TYPICAL.
23. FIELD VERIFY ROOF CONFIGURATION AND MATERIALS IN THIS AREA PRIOR TO
BIDDING; NO AS-BUILT INFORMATION AVAILABLE; VERIFICATION NEEDED TO ENSURE
DRAINAGE PROVIDED IS ADEQUATE TO HANDLE CURRENT DRAINAGE AREA
SERVICED.
24. CLEAN (POWERWASH) ALL CONCRETE FLOOR AND CONCRETE BLOCK SURFACES
AT CEILING, WALLS, FLOORS, RISERS AND TREADS.
25. REMOVE ALL (E) SCUPPERS AND GUTTER FLASHING TO BE REPLACED TYPICAL.
26. MAINTAIN AND PROTECT (E) ECM EQUIPMENT AND ASSOCIATED
COMMUNICATIONS LINES ON (E) BOILER(S) AND (E) GAS REGULATOR/METER;
COORDINATE EFFORT WITH 30 CES/CEAOI TO ENSURE SYSTEM IS NOT DAMAGED.
27. (E) TRANSFORMER AND ELECTRICAL CABINET TO REMAIN TYPICAL.
28. REMOVE (E) SCREEN WALL TO BE REPLACED WITH (N) ENCLOSURE.
29. REMOVE ALL TELEVISION CABLE SYSTEMS, COMMUNICATIONS SYSTEMS (TELEPHONE
AND ALARM PANEL) AND DISTRIBUTION PANELS TO BE REPLACED THROUGHOUT
BUILDING; COORDINATE EFFORT WITH FACILITY MANAGER TO ENSURE CABLE
SERVICE IS NOT SUPPORTING OTHER FACILITIES UNDER THIS EFFORT AND
INTERRUPTION OF SERVICE TO OTHER FACILITIES IS PREVENTED.
30. REMOVE (E) ELECTRICAL WIRING TO EXTENT NEEDED TO SUPPORT RECONFIGURED
FLOOR PLAN. (E) PANELS MAY BE REUSED BUT CIRCUIT BREAKERS SHOULD BE
INSPECTED/TESTED TO ENSURE REPLACEMENT IS NOT NEEDED.
31. REMOVE (E) GAS REGULATOR TO BE REPLACED; COORDINATE WITH FACILITY
MANAGER TO VERIFY EXTENT OF SERVICE PROVIDED BY REGULATOR TO ENSURE
SERVICE TO OTHER FACILITIES IS NOT INTERRUPTED.
32. REMOVE ALL (E) SMOKE DETECTORS AND FIRE ALARM NOTIFICATION EQUIPMENT TO
BE REPLACED.
33. NOT USED.
34. CUT (N) OPENING IN (E) CMU WALL FOR (N) DOORWAY; SEE FLOOR PLAN FOR
ADDITIONAL INFORMATION.
35. VERIFY CODE COMPLIANCE OF SPACING OF PICKETS, CORRECT AS NECESSARY.
36. VERIFY WOOD CONDITION, REPLACE AS NECESSARY.
DAYROOMDAYROOM
13 13
TYPICAL DEMOLITION NOTES 45
AD101
13123
13121
0 13
SCALE: NOT TO SCALE
NORTH
PROJECT
SEE TYPICAL MODULE DEMOLITION FLOOR
PLAN FOR TYPICAL NOTES. ALL NOTES SHOWN
ON THIS DRAWING ARE NOT TYPICAL.
SEE TYPICAL MODULE DEMOLITION FLOOR
PLAN FOR TYPICAL NOTES. ALL NOTES SHOWN
ON THIS DRAWING ARE NOT TYPICAL.
29 18
A. CAREFUL COORDINATION IS NEEDED WITH CONSTRUCTION DOCUMENTS
DESCRIBING NEW WORK TO ENSURE THAT BUILDING ELEMENTS INTENDED TO
REMAIN ARE ADEQUATELY PROTECTED AND MAINTAINED. ADDITIONAL DEMOLITION
MAY BE REQUIRED BASED ON INFORMATION FOUND ON OTHER DRAWINGS.
B. ALL DEMOLITION SHALL BE EXECUTED AS NOT TO DAMAGE (E) ELEMENTS, INCLUDING
LANDSCAPING AND IRRIGATION SYSTEMS WHICH ARE TO REMAIN.
C. EXISTING ELEMENTS TO REMAIN SHALL BE PROTECTED TO THE FULLEST EXTENT
POSSIBLE. ALL ELEMENTS OF THE STRUCTURE THAT ARE TO REMAIN & WHICH ARE
DAMAGED DURING DEMOLITION OPERATIONS SHALL BE REPLACED BY THE
CONTRACTOR AT NO COST TO THE GOVERNMENT.
D. ALL WORK NOT SPECIFICALLY MENTIONED THAT INTERFERES WITH NEW
CONSTRUCTION SHALL BE DEMOLISHED IN A MANNER THAT PROVIDES PROPER
INTERFACE WITH NEW CONSTRUCTION. PATCH AND REPAIR AS NECESSARY.
E. THE CONTRACTOR SHALL ENACT ALL MEASURES NECESSARY TO PROTECT (E)
BUILDING ELEMENTS TO REMAIN. PROMPTLY REPAIR DAMAGE DURING DEMOLITION
TO MATERIALS AND OTHER EXISTING BUILDING ELEMENTS TO REMAIN.
F. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS PRIOR TO BEGINNING WORK.
COMMENCEMENT OF WORK INDICATES ACCEPTANCE BY CONTRACTOR OF EXISTING
CONDITIONS.
G. CONTRACTOR SHALL FIELD VERIFY AND PROTECT ALL (E) UTILITIES AS DIRECTED BY
CONTRACT PRIOR TO STARTING ANY WORK.
H. PROPER MEASURES SHALL BE TAKEN TO CAP, DISCONNECT OR RELOCATE ANY
EXISTING WATER, GAS, ELECTRICAL, WASTE OR COMMUNICATION LINES AS NEEDED
TO SUPPORT NEW CONSTRUCTION.
I. NOTIFY CONTRACTING OFFICER IF ANY EXISTING UTILITY SHALL INTERFERE WITH
CONSTRUCTION. INSPECT, REPAIR AND VERIFY THAT NO OBSTRUCTIONS EXIST IN ALL
UTILITY CHASES & WALLS FOR NEW UTILITY INSTALLATION.
J. PROTECT AND MAINTAIN ALL (E) LANDSCAPE AREAS INSIDE OF INDICATED AREA OF
WORK. ENSURE ALL IRRIGATION IS OPERATING CORRECTLY AND PROVIDE ANY
NECESSARY REPAIRS PRIOR TO COMPLETION OF PROJECT.
K. CONTRACTOR SHALL PROVIDE ACCESS TO ALL AREAS OUTSIDE OF AREA OF WORK
AS OTHER BUILDINGS SHALL BE OCCUPIED DURING CONSTRUCTION.
L. CONTRACTOR SHALL COORDINATE WITH CONTRACTING OFFICER AND INSTALLATION
PROJECT MANAGER TO IDENTIFY AREA FOR PROJECT LAYDOWN.
M. CONTRACTOR SHALL ADEQUATELY PROTECT LAYDOWN AREA, ALL WASTE
MANAGEMENT ACTIVITIES AND AREA OF CONSTRUCTION AS ADJACENT FACILITIES
WILL BE OCCUPIED DURING CONSTRUCTION.
N. PRIOR TO COMPLETING CONSTRUCTION, CONTRACTOR SHALL CLEAN THE SITE OF
ALL CONSTRUCTION DEBRIS, SPILLAGE AND DAMAGE TO ALL SITE ELEMENTS TO
INCLUDE WALKWAYS, PARKING LOTS, LANDSCAPING AND ADJACENT FACILITIES.
O. CONTRACTOR SHALL FIELD VERIFY LOCATION AND PROTECT ALL DRAIN INLETS IN
AREA OF WORK AND THOSE AFFECTED BY AREA OF WORK (i.e. WITHIN DRAINAGE
AREA); COORDINATE EFFORT WITH 30 CES/CEAN TO CONFIRM REQUIREMENTS AND
ENSURE COMPLIANCE WITH INSTALLATION, COUNTY AND STATE REQUIREMENTS.
P. REPLACE ALL EXISTING EXTERIOR AND INTERIOR SIGNAGE TYPICAL THROUGHOUT
FACILITY. ALL NEW SIGNAGE TO MEET STANDARDS AS OUTLINED IN UFC 3-120-01
AIR FORCE SIGN STANDARD & INSTALLATION FACILITIES EXCELLENCE STANDARDS.
STOR.
DAYROOMDAYROOM
DINING
JI Java INTERIOR NOT IN CONTRACT
PATIOPATIO
OFFICE
109.1
451.1 SF
MECHANICAL
109.2
404.4 SF
TYPICAL AT EACH
COLUMN
29 30
STOR.
DAYROOMDAYROOM
DINING
STOR.
DAYROOMDAYROOM
DINING
PATIOPATIO
ROOF AREA
AD101
4 44
STOR.
DINING
PATIO
AD301
29 30 32
22 3
4 444 99
3 33
AD301
NORTH
PROJECT
NORTH
TRUE
NORTH
PROJECT
NORTH
TRUE
NORTH
PROJECT
NORTH
TRUE
A
TE
D
ES
C
RI
PT
IO
N
O F
RE
V
IS
IO
N
SY
M
BO
L
PROJECT #
SHEET #
DRAWING #
D A
TE
OF
SC
A
LE
D
RA
W
IN
G T
ITL
E
PR
O
JE
C
T
TIT
LE
D
RA
W
N
RE
V
IE
W
ED
D
ES
IG
N
ED
F O
R
O
F F
I C
I A
L
U
L
Y
I N
F O
R M
A T
I O
N
S
A F
E G
U A
R D
I N
G
Q
U I R e i n f o r m a t i o n c o n t a i n e d o n t h i s d r a w i n g s h a l l r e m a i n u n d e r t h e c o n t r o l o f t h e o r i g i n a t i n g r e q u e s t e r o r a g e n c y o r i t s s u c c e s s o r i n f u n c t i o n a t a l l t i m e f o r m a t i o n s a f e g u a r d i n g i s t h e r e s p o n s i b i l i t y o f t h e i n d i v i d u a l a g e n c y c o m p a n y r e q u e s t i n g t h e d a t a a n d t a k i n g o r i g i n a l p o s s e s s i o n o f t h i s d r a w i n l e a s e d i s c l o s u r e o f d a t a t o a n y p a r t y b e y o n d t h e o r i g i n a l r e q u e s t a n d i n t e n d e d u s e i s p r o h i b i t e p u b l i c p u b l i c a t i o n o f t h e d a t a b y a n y m e a n s o r a n a l y s e s t h e r e o f i s a u t h o r i z e o n c o m p l e t i o n o f t h e u s e o f t h e d a t a c o n t a i n e d o n t h i s d r a w i n g t h e d r a w i n g m u s t b e r e t u r n e d o r d e s t r o y e r e c t a n y q u e s t i o n s t o t h e
E n g i n e e r i n g
S u p p o r t
E l e m e n t
C
E S
C
E C
B a t
I n f o r m a t i o n s a f e g u a r d i n g r e q u i r e m e n t s a r e p e r
A
F M
A N
A
F I
D g a n d
E x e c u t i v e
O r d e r w h e n a p p l i c a b l e
D O
N O
T D
U
PL
IC
A
TE
T
H
IS
D R
A W
IN
G
O
R T
H E
D A
TA
C
O N
TA
IN
ED
O
N
IT
09-1253
AD102
A pr
A S
N O
TE
D
KR
G
KR
G
KR
G
RE
PA
IR
IN
TE
RI
O R/
EX
TE
RI
O
R O
F D
O
RM
, B
LD
G
TH
IR
D F
LO
O
R
R O
O F
D
EM
O
LI
TIO
N
P
LA
N , B
LD
G
ROOF DEMOLITION PLAN, BLDG 13321
SCALE: 1/8" = 1'-0"
DEMOLITION NOTES 15
THIRD FLOOR DEMOLITION PLAN, BLDG 13321
SCALE: 1/8" = 1'-0"
1. REMOVE ALL EXISTING ATTIC VENTS TO BE REPLACED; TYPICAL AT (10) LOCATIONS.
2. REMOVE ALL EXISTING BUILT-UP ROOFING MATERIALS TO BE REPLACED WITH NEW.
3. INSPECT AND REPAIR ALL FLASHING AND COUNTERFLASHING AT ROOF PARAPETS
AND PREPARE FOR PAINT; REMOVE ALL FLASHING AND COUNTERFLASHING AT
WINDOWS, DOORS AND OTHER AREAS TO BE REPLACED WITH NEW.
4. REMOVE ALL ROOF VENTS (SHOWN AND UNSHOWN) TO BE REPLACED WITH NEW;
FIELD VERIFY QUANTITY OF ALL PLUMBING & EXHAUST VENTS TO BE REPLACED.
5. REMOVE ALL ROOF DRAINS & PIPES TO BE REPLACED, TYPICAL OF (6) THIS ROOF.
6. REMOVE ALL 30" x 36" ACCESS DOORS TO BE REPLACED; TYPICAL AT (2) LOCATIONS.
7. LINE OF EXISTING WALLS BELOW ROOF FOR REFERENCE ONLY.
8. EXISTING SHAFT FOR BOILER EQUIPMENT TO REMAIN TYPICAL; CLEAR SHAFT FOR NEW
BOILER EQUIPMENT.
9. INSPECT (E) CONCRETE ROOF TILES, SUPPORTING STRUCTURE (i.e. CLEATS) &
BUILDING PAPER. INSPECT PLYWOOD SHEATHING FOR ANY DAMAGE AND/OR NEED
TO REPAIR OR REPLACE. TYPICAL AT ALL CONCRETE TILE ROOF AREAS.
10. INSPECT ALL SHEATHING AND SUPPORTING MATERIALS BELOW (E) BUILT-UP ROOF AT
THIS AREA TO BE REPLACED TYPICAL; REPAIR AND REPLACE AS NEEDED FOR
WATERTIGHT INSTALLATION TYPICAL.
11. FIELD VERIFY ROOF CONFIGURATION AND MATERIALS IN THIS AREA PRIOR TO
BIDDING; NO AS-BUILT INFORMATION AVAILABLE.
12. REMOVE ALL (E) GUTTERS, SCUPPERS, FLASHING AND DOWNSPOUTS TO BE
REPLACED.
13. FIELD VERIFY LOCATION OF (E) WIRELESS "WIFI" SYSTEM INSTALLED ON ROOF AND
EXTERIOR OF BUILDING; DETERMINE (N) LOCATION AND COORDINATE WITH FACILITY
MANAGER PRIOR TO DISCONNECTION TO ENSURE SERVICE IS NOT INTERRUPTED AT
OTHER (E) OCCUPIED BUILDINGS.
14. REMOVE ALL DEBRIS FROM ANY GUTTERS, SCUPPERS OR DOWNSPOUTS THAT ARE TO
REMAIN TYPICAL.
15. SEE ROOF DEMOLITION PLAN FOR ADDITIONAL INFORMATION THIS AREA TYPICAL.
16. REMOVE (E) ROOF ACCESS HATCHES TYPICAL TO BE REPLACED; FIELD VERIFY
LOCATIONS AND QUANTITY.
17. VERIFY CONDITION OF EXHAUST FANS AND REPLACE IF NEEDED TO MEET
REQUIREMENTS.
KEY PLAN 65
13123
13121
0 13
SCALE: NOT TO SCALE
SEE SHEET AD-101, FIRST & SECOND FLOOR DEMOLITION
PLAN AND TYPICAL MODULE DEMOLITION PLAN FOR
ADDITIONAL INFORMATION. ALL NOTES SHOWN ON THIS
DRAWING ARE NOT TYPICAL.
TYPICAL DEMOLITION NOTES 45
A. CAREFUL COORDINATION IS NEEDED WITH CONSTRUCTION DOCUMENTS
DESCRIBING NEW WORK TO ENSURE THAT BUILDING ELEMENTS INTENDED TO
REMAIN ARE ADEQUATELY PROTECTED AND MAINTAINED. ADDITIONAL DEMOLITION
MAY BE REQUIRED BASED ON INFORMATION FOUND ON OTHER DRAWINGS.
B. ALL DEMOLITION SHALL BE EXECUTED AS NOT TO DAMAGE (E) ELEMENTS, INCLUDING
LANDSCAPING AND IRRIGATION SYSTEMS WHICH ARE TO REMAIN.
C. EXISTING ELEMENTS TO REMAIN SHALL BE PROTECTED TO THE FULLEST EXTENT
POSSIBLE. ALL ELEMENTS OF THE STRUCTURE THAT ARE TO REMAIN & WHICH ARE
DAMAGED DURING DEMOLITION OPERATIONS SHALL BE REPLACED BY THE
CONTRACTOR AT NO COST TO THE GOVERNMENT.
D. ALL WORK NOT SPECIFICALLY MENTIONED THAT INTERFERES WITH NEW
CONSTRUCTION SHALL BE DEMOLISHED IN A MANNER THAT PROVIDES PROPER
INTERFACE WITH NEW CONSTRUCTION. PATCH AND REPAIR AS NECESSARY.
E. THE CONTRACTOR SHALL ENACT ALL MEASURES NECESSARY TO PROTECT (E)
BUILDING ELEMENTS TO REMAIN. PROMPTLY REPAIR DAMAGE DURING DEMOLITION
TO MATERIALS AND OTHER EXISTING BUILDING ELEMENTS TO REMAIN.
F. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS PRIOR TO BEGINNING WORK.
COMMENCEMENT OF WORK INDICATES ACCEPTANCE BY CONTRACTOR OF EXISTING
CONDITIONS.
G. CONTRACTOR SHALL FIELD VERIFY AND PROTECT ALL (E) UTILITIES AS DIRECTED BY
CONTRACT PRIOR TO STARTING ANY WORK.
H. PROPER MEASURES SHALL BE TAKEN TO CAP, DISCONNECT OR RELOCATE ANY
EXISTING WATER, GAS, ELECTRICAL, WASTE OR COMMUNICATION LINES AS NEEDED
TO SUPPORT NEW CONSTRUCTION.
I. NOTIFY CONTRACTING OFFICER IF ANY EXISTING UTILITY SHALL INTERFERE WITH
CONSTRUCTION. INSPECT, REPAIR AND VERIFY THAT NO OBSTRUCTIONS EXIST IN ALL
UTILITY CHASES & WALLS FOR NEW UTILITY INSTALLATION.
J. PROTECT AND MAINTAIN ALL (E) LANDSCAPE AREAS INSIDE OF INDICATED AREA OF
WORK. ENSURE ALL IRRIGATION IS OPERATING CORRECTLY AND PROVIDE ANY
NECESSARY REPAIRS PRIOR TO COMPLETION OF PROJECT.
K. CONTRACTOR SHALL PROVIDE ACCESS TO ALL AREAS OUTSIDE OF AREA OF WORK
AS OTHER BUILDINGS SHALL BE OCCUPIED DURING CONSTRUCTION.
L. CONTRACTOR SHALL COORDINATE WITH CONTRACTING OFFICER AND INSTALLATION
PROJECT MANAGER TO IDENTIFY AREA FOR PROJECT LAYDOWN.
M. CONTRACTOR SHALL ADEQUATELY PROTECT LAYDOWN AREA, ALL WASTE
MANAGEMENT ACTIVITIES AND AREA OF CONSTRUCTION AS ADJACENT FACILITIES
WILL BE OCCUPIED DURING CONSTRUCTION.
N. PRIOR TO COMPLETING CONSTRUCTION, CONTRACTOR SHALL CLEAN THE SITE OF
ALL CONSTRUCTION DEBRIS, SPILLAGE AND DAMAGE TO ALL SITE ELEMENTS TO
INCLUDE WALKWAYS, PARKING LOTS, LANDSCAPING AND ADJACENT FACILITIES.
O. CONTRACTOR SHALL FIELD VERIFY LOCATION AND PROTECT ALL DRAIN INLETS IN
AREA OF WORK AND THOSE AFFECTED BY AREA OF WORK (i.e. WITHIN DRAINAGE
AREA); COORDINATE EFFORT WITH 30 CES/CEAN TO CONFIRM REQUIREMENTS AND
ENSURE COMPLIANCE WITH INSTALLATION, COUNTY AND STATE REQUIREMENTS.
P. REPLACE ALL EXISTING EXTERIOR AND INTERIOR SIGNAGE TYPICAL THROUGHOUT
FACILITY. ALL NEW SIGNAGE TO MEET STANDARDS AS OUTLINED IN UFC 3-120-01
AIR FORCE SIGN STANDARD & INSTALLATION FACILITIES EXCELLENCE STANDARDS.
SEE SHEET AD-101, FIRST & SECOND FLOOR DEMOLITION
PLAN AND TYPICAL MODULE DEMOLITION PLAN FOR
ADDITIONAL INFORMATION. ALL NOTES SHOWN ON THIS
DRAWING ARE NOT TYPICAL.
STOR.
DAYROOM DAYROOM
DINING
STOR.
DAYROOM DAYROOM
DINING
PATIOPATIO
MIN SLOPE
1/4" PER FT TYP
MIN SLOPE
1/4" PER FT TYP
SLOPE
5:12 TYP.
SLOPE
5:12 TYP.
MIN SLOPE
1/4" PER FT TYP
10 10
13 1314 1416
10131416
141311
12 12
3 3
NORTH
PROJECT
NORTH
PROJECT
NORTH
TRUE
NORTH
PROJECT
NORTH
TRUE
DNUP DNUP
DNUP
D A
TE
D
ES
C
RI
PT
IO
N
O F
RE
V
IS
IO
N
SY
M
BO
L
PROJECT #
SHEET #
DRAWING #
D A
TE
OF
SC
A
LE
D
RA
W
IN
G T
ITL
E
PR
O
JE
C
T
TIT
LE
D
RA
W
N
RE
V
IE
W
ED
D
ES
IG
N
ED
F O
R
O
F F
I C
I A
L
U
L
Y
I N
F O
R M
A T
I O
N
S
A F
E G
U A
R D
I N
G
Q
U I R e i n f o r m a t i o n c o n t a i n e d o n t h i s d r a w i n g s h a l l r e m a i n u n d e r t h e c o n t r o l o f t h e o r i g i n a t i n g r e q u e s t e r o r a g e n c y o r i t s s u c c e s s o r i n f u n c t i o n a t a l l t i m e f o r m a t i o n s a f e g u a r d i n g i s t h e r e s p o n s i b i l i t y o f t h e i n d i v i d u a l a g e n c y c o m p a n y r e q u e s t i n g t h e d a t a a n d t a k i n g o r i g i n a l p o s s e s s i o n o f t h i s d r a w i n l e a s e d i s c l o s u r e o f d a t a t o a n y p a r t y b e y o n d t h e o r i g i n a l r e q u e s t a n d i n t e n d e d u s e i s p r o h i b i t e p u b l i c p u b l i c a t i o n o f t h e d a t a b y a n y m e a n s o r a n a l y s e s t h e r e o f i s a u t h o r i z e o n c o m p l e t i o n o f t h e u s e o f t h e d a t a c o n t a i n e d o n t h i s d r a w i n g t h e d r a w i n g m u s t b e r e t u r n e d o r d e s t r o y e r e c t a n y q u e s t i o n s t o t h e
E n g i n e e r i n g
S u p p o r t
E l e m e n t
C
E S
C
E C
B a t
I n f o r m a t i o n s a f e g u a r d i n g r e q u i r e m e n t s a r e p e r
A
F M
A N
A
F I
D g a n d
E x e c u t i v e
O r d e r w h e n a p p l i c a b l e
D O
N O
T D
U
PL
IC
A
TE
T
H
IS
D R
A W
IN
G
O
R T
H E
D A
TA
C
O N
TA
IN
ED
O
N
IT
09-1253
A-101
A pr
A S
N O
TE
D
KR
G
KR
G
KR
G
RE
PA
IR
IN
TE
RI
O R/
EX
TE
RI
O
R O
F D
O
RM
, B
LD
G
FI
RS
T
S
EC
O N
D F
LO
O
R
PL
A N
, B
LD
G
TY
PI
C A
L M
O D
UL
E
FL
O
O R
PL
A
N
SECOND FLOOR PLAN, BLDG 13323
SCALE: 1/8" = 1'-0"
44 TYPICAL NOTES 14
FIRST FLOOR PLAN, BLDG 13321
SCALE: 1/8" = 1'-0" 42
TYPICAL MODULE FLOOR PLAN 13
REFERENCE NOTES 15
A. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL COMPLY WITH REQUIREMENTS AS
OUTLINED IN UFC 4-010-01/02 MINIMUM ANTITERRORISM STANDARDS FOR DOD
BUILDINGS.
B. PROVIDE APPROPRIATE HVAC SYSTEM AS REQUIRED PER THE FOLLOWING:
-- UFC 3-400-01 ENERGY CONSERVATION
-- UFC 3-401-01FA UTILITY MONITORING & CONTROL SYSTEMS
-- UFC 3-410-01FA HVAC
-- ETL 04-3 : DESIGN CRITERIA FOR PREVENTION OF MOLD IN AF FACILITIES
-- UNACCOMPANIED HOUSING GUIDE, US AIR FORCE
C. SEE FINISH, DOOR AND WINDOW SCHEDULES FOR ADDITIONAL INFORMATION.
D. INSTALL SPRINKLER FIRE PROTECTION SYSTEM THROUGHOUT FACILITY COMPLIANT
WITH NFPA REQUIREMENTS.
E. CONTRACTOR SHALL PATCH AND REPAIR ALL CONCRETE SLABS TO BE
STRUCTURALLY SOUND WHERE (E) UTILITY CHASES ARE REMOVED AND NOT USED.
F. ALL NEW COMMUNICATIONS WIRING, PANELS AND EQUIPMENT TO INCLUDE
TELEVISION CABLE, TELEPHONE, WI-FI WIRING AND ALARM PANEL WIRING SHALL
MEET CURRENT STANDARDS AS DETERMINED BY 30 SPACE COMMUNICATIONS
SQUADRON.
G. ALL INTERIOR WALLS AND INFILL PANELS SHALL CONTAIN A MINIMUM OF R-19
SOUND INSULATION TYPICAL.
1. PAINT AND REINSTALL AS NEEDED REFURBISHED METAL HANDRAILS, GUARDRAILS
AND METAL COLUMNS TYPICAL.
2. PATCH AND PAINT ALL EXTERIOR PLASTER SURFACES ON (E) STAIRS.
3. 5/8" GYPSUM BOARD ON 7/8" FURRING HAT CHANNELS AT ALL (E) CONCRETE
MASONRY WALLS TYPICAL.
4. 36" x 48" FIBERGLASS SHOWER PAN WITH FIBERGLASS SURROUND; SHOWER CURB
TO BE A MINIMUM OF 4" TYPICAL; PROVIDE A HEAVY-DUTY HAND-HELD
SHOWERHEAD CONNECTED TO A FLEXIBLE HOSE THAT FITS INTO AN ADJUSTABLE
HEIGHT HOLDER MOUNTED ON A VERTICAL ROD.
4.1. AMERICAN STANDARD ACRYLUX 48" x 34" SHOWER BASE, TEXTURED BOTTOM, WHITE
4.2. PRICE PFISTER 16 SERIES HANDHELD SHOWER, CHROME WITH 42 SERIES, PARISA
SHOWER FAUCET, CHROME
5. LOW-FLOW TOILET TO BE AMERICAN STANDARD CADET FLOWISE RIGHT HEIGHT
ELONGATED VALVE TYPE TOILET 1.1 GPF TOILET, WHITE
5.1. SEAT: AMERICAN STANDARD 5324.019 RISE AND SHINE SOLID PLASTIC CLOSED
FRONT SEAT WITH COVER
6. 36"w PLASTIC LAMINATE WOOD CABINET w/ UNDERCOUNTER MOUNTED SINK;
COUNTER TOP SHALL BE 30" ABOVE FINISH FLOOR; PROVIDE A MINIMUM OF (2)
8"w x 3"dp DRAWERS WITH REMAINING AREA UNDER THE VANITY AS STORAGE
WITH CABINET DOORS.
7. RECESSED MEDICINE CABINET w/ MIRROR, NOMINALLY 20"w x 26"h x 5"dp
ADJACENT TO VANITY, HINGED NEXT TO MIRROR WITH (3) ADJUSTABLE INTERIOR
SHELVES; KOHLER SINGLE DOOR ALUMINUM CABINET K-CB-CLC2026FS
8. SHELF AND POLE AT +66" AFF ON (2) WALLS AS SHOWN
9. 6" x 36" CONTINUOUS SHAFT FOR DRYER VENTING TYPICAL
10. 6" x 24" CONTINUOUS SHAFT FOR RANGE VENTING TYPICAL
11. 6" x 24" CONTINUOUS SHAFT FOR POWER/COMMUNICATION LINES AS NEEDED
12. 6" x 18" CONTINUOUS SHAFT FOR POWER/COMMUNICATION LINES AS NEEDED
13. COUNTERTOP AT +36" AFF w/ SUPPORTING WALL BELOW TYPICAL
14. WASHER TYPICAL (NIC); PROVIDE HOT/COLD WATER CONNECTIONS, POWER
AND DRAIN LINE
15. DRYER TYPICAL (NIC); PROVIDE GAS LINE, 220v OUTLET AND DRYER VENT IN
SHAFT PROVIDED. MINIMIZE BENDS AND PROVIDE REMOVABLE SCREENS FOR
CLEANOUT.
16. PROVIDE (2) BURNER ELECTRIC RANGE TYPICAL; KITCHENAID KECC056RBL,
CERAMIC GLASS SURFACE; PROVIDE MICROHOOD CONVECTION OVEN
COMBINATION; KENMORE ELITE 86013;VENT RANGE HOOD TO SHAFT PROVIDED.
17. PROVIDE 54"w PLASTIC LAMINATE WOOD CABINET w/ INSULATED STAINLESS STEEL
SINK TYPICAL; SINK TO BE AMERICAN STANDARD 7504.000 UNDERCOUNTER
MOUNT, STAINLESS STEEL WITH DISPOSAL; FAUCET TO BE AMERICAN STANDARD
4101.350 ARCH SINGLE CONTROL KITCHEN FAUCET WITH PULL-OUT SPRAY.
18. PROVIDE 36"w SPACE FOR REFRIGERATOR (NIC); PROVIDE ELECTRICAL OUTLET
AND WATER CONNECTION FOR ICE MAKER
19. INFILL (E) OPENINGS IN CMU WALL w/ STEEL STUD, INSULATION, EXTERIOR PLASTER ON EXTERIOR FACE AND 5/8" GYPSUM BOARD ON ALL INTERIOR FACES FLUSH w/
FURRED WALL OR ADJACENT INTERIOR WALL
20. TYPICAL INTERIOR WALL CONSTRUCTION SHALL BE 3 5/8" METAL STUDS w/ R-19
SOUND INSULATION AND 5/8" GYPSUM BOARD EACH SIDE
21. 6" x 24" CONTINUOUS SHAFT FOR BATHROOM VENTING AND PLUMBING
22. PROVIDE BOBRICK HEAVY DUTY 1" STAINLESS STEEL CURTAIN ROD BOB 6107X W/
FOCUS HOOKLESS SHOWER CURTAIN OR APPROVED EQUAL.
23. 14"w x 36"h PLASTIC LAMINATE WOOD CABINET w/DOOR AND COUNTERTOP TO
MATCH KITCHEN CABINETS.
24. INFILL (E) OPENING IN CMU WALL TO ACCEPT NEW DOOR OR WINDOW.
25. INFILL (E) SHAFT OPENING NOT USED THROUGH EACH FLOOR IN (E) CONCRETE
SLAB TYPICAL
26. SEAL ALL WALLS WITH APPROPRIATE WATERPROOF FINISH, CLEAN ALL FLOOR
SURFACES, REPLACE FLOOR DRAIN(S), AND GENERALLY CLEAN AREA TO RECEIVE
(N) BOILER(S), ELECTRICAL AND COMMUNICATIONS PANELS
27. 24"w FULL HT PLASTIC LAMINATE WOOD CABINET FOR RESTROOM STORAGE
28. INSTALL (N) HANDRAIL AT +34" ABV. NOSE OF (E) STAIR TYPICAL; HANDRAIL TO BE
1 1/2" PIPE RAIL, PAINTED.
29. CLEAN ALL CONCRETE TO PREPARE AREA FOR INSTALLATION OF (N) EQUIPMENT.
30. REMOVE AND REPLACE ALL FLOOR DRAINS TYPICAL; FIELD VERIFY CONDITION OF
(E) DRAIN LINES AND REPAIR AS NEEDED.
31. LINE OF (E) SOFFIT IN DORM MGR OFFICE FOR LINES (POWER, COMMUNICATIONS
AND BOILER LINES); ENSURE EVERY EFFORT IS MADE TO MINIMIZE INTRUSION INTO
DORM MGR's OFFICE WITH SOFFIT.
32. (N) 4" REINFORCED CONCRETE SLAB IN UTILITY AREA; SLOPE TO DRAIN TOWARDS
GATE TYPICAL.
33. (N) 8" CMU WALL AT 9'-4"h TYPICAL AT UTILITY AREA; PROVIDE 6' CLEAR OPENING w/ LOCKABLE GATE AS SHOWN. GATE TO BE METAL FRAME w/ SYNTHETIC WOOD
BOARDS ATTACHED TO FACE OF METAL FRAME.
34. (E) TRANSFORMER AND ELECTRICAL CABINET TO REMAIN; PAINT CABINET TO
MATCH BUILDING COLOR.
35. SEE ROOF PLAN FOR INFORMATION ON ALL ROOF AND COVERED AREAS.
36. (E) PATIO WALLS AND WALKWAYS TO REMAIN TYPICAL; CLEAN, PATCH, REPAIR
AND PAINT TO MATCH; SEE SITE PLAN FOR ADDITIONAL INFORMATION.
37. PROVIDE A FULL WIDTH MIRROR ABOVE THE VANITY, WITH TOP OF MIRROR A
MINIMUM OF 72" ABOVE THE FINISH FLOOR; BOTTOM OF THE MIRROR SHALL
EXTEND TO THE TOP OF THE BACK SPLASH.
38. 36"w OR 42"w PLASTIC LAMINATE WOOD VANITY BASE CABINET w/
UNDERCOUNTER MOUNTED SINK; VERIFY WIDTH WITH LOCATION; COUNTER TOP
SHALL BE 30" ABOVE FINISH FLOOR; PROVIDE A MINIMUM OF (2) 8"w x 3"dp
DRAWERS WITH REMAINING AREA UNDER THE VANITY AS STORAGE ACCESSED BY
CABINET DOORS.
39. PROVIDE FOR INSTALLATION OF ELECTRONIC KEY CARD SYSTEM AT EXTERIOR
SWINGING DOORS AND INTERIOR BEDROOM DOORS TYPICAL; SYSTEM SHALL BE
COMPATIBLE WITH (E) SYSTEM.
40. REINSTALL (E) ECM EQUIPMENT AND ASSOCIATED COMMUNICATIONS LINES ON
(N) BOILER(S) TYPICAL; COORDINATE EFFORT WITH 30 CES/CEAOI FOR SPECIFIC
DIRECTION AND INSTALLATION REQUIREMENTS.
41. PROVIDE CHAIN LINK MESH AND SUPPORTING STRUCTURE WITH ADEQUATE
SUPPORT TO ENSURE NO SAGGING INSTALLED HORIZONTALLY OVER EQUIPMENT
ENCLOSURE TO COMPLY WITH CURRENT ANTITERRORISM STANDARDS AND
ALLOW FOR EQUIPMENT REMOVAL.
42. PROVIDE 18"x60" MIRROR ON THE INSIDE OF THE CLOSET DOOR OR BATHROOM
DOOR AS SHOWN.
43. Not used.
44. PROVIDE (2) TOWEL BARS, EACH AT LEAST 24" LONG, WITH (1) INTEGRAL TO
SHOWER DOOR AS NOTED AND THE OTHER AT LOCATION INDICATED TYPICAL.
45. PROVIDE (1) ROBE HOOK ON THE BATHROOM SIDE OF THE BATHROOM DOOR.
46. PROVIDE WALL MOUNTED 30"w x 24"h x 8"dp PLASTIC LAMINATE WOOD
STORAGE CABINET WITH DOORS AND (1) ADJ SHELF OVER THE WAINSCOT OVER
EACH WATER CLOSET TYPICAL; FINISH TO MATCH BATHROOM VANITY CABINET.
47. PROVIDE HEAVY DUTY TOILET TISSUE HOLDER AT SIDE OF BATHROOM VANITY.
48. LAVATORY SINK (UNDERCOUNTER MOUNTED) WITH FAUCET
48.1. AMERICAN STANDARD OVALYN UNDERCOUNTER SINK 0495.300, WHITE
48.2. PRICE PFISTER, 42 SERIES, PARISA, 4" CENTERSET LAVATORY FAUCET, J42-AMFC,
POLISHED CHROME
49. INSTALL FLOOR MOUNTED DOOR STOPS AS NEEDED TO PREVENT DOORS FROM
DAMAGING ADJACENT SURFACES (GENERALLY IN SAME LOCATIONS AS THOSE
REMOVED).
50. NOT USED
51. PROVIDE CABINET MOUNTED FIRE EXTINGUISHER UNDER SINK IN APPROPRIATE
LOCATION.
52. PROVIDE INDIVIDUAL THERMOSTATS IN EACH BEDROOM AND COMMON SPACE.
53. PROVIDE (N) DOOR IN (E) CMU WALL; PROVIDE ALL NECESSARY STRUCTURAL
IMPROVEMENTS TO SUPPORT (E) STRUCTURE.
54. NEW CMU WALL TO MATCH EXISTING.
KEY PLAN 65
13123
13121
0 13
SCALE: NOT TO SCALE
NORTH
PROJECT
SEE TYPICAL MODULE FLOOR PLAN FOR
TYPICAL NOTES. ALL NOTES SHOWN ON THIS
DRAWING ARE NOT TYPICAL.
SCHEDULES 24
A101
E
LAUNDRY
BATH
BATHBATH
BATH
KITCHEN
CLOSET
CLOSET
CLOSET
CLOSET
BEDROOM
109A
169.4 SF
BEDROOM
109B
164.7 SF
BEDROOM
109C
164.7 SF
BEDROOM
109D
169.4 SF
PATIO PATIO
OFFICE
109.1
434.5 SF
MECHANICAL
109.2
404.4 SF
A
LAUNDRY
SEE TYPICAL MODULE FLOOR PLAN FOR
TYPICAL NOTES. ALL NOTES SHOWN ON THIS
DRAWING ARE NOT TYPICAL.
GI Java
NIC
COMMON AREA
462.6 SF
6'-8"11'-4"
A301
A301
BEDROOM
210A
169.4 SF
BEDROOM
210B
164.7 SF
BEDROOM
210C
164.7 SF
BEDROOM
210D
169.4 SFKITCHEN LA
UN
D
RY
BATH
BATH
BATH
BATH BATH
BATHBATH
BATH
KITCHEN
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
BEDROOM
209A
169.4 SF
BEDROOM
209B
164.7 SF
BEDROOM
209C
164.7 SF
BEDROOM
209D
169.4 SF
PATIO PATIO
LA
UN
D
RY
COMMON AREA
462.6 SF
COMMON AREA
462.6 SF
A301
A301
'-0
8'-7"
BEDROOM
209B
164.7 SF
BEDROOM
209C
164.7 SF
KITCHEN LAUNDRY
CLOSET
BATHBATH
BATHBATH
CLOSETCLOSET
CLOSET
C
A
B
C
A
B
B B
C
CC
C
C C
15161718
CARPET / VINYL
CARPET / VINYL
VINYL / CARPET
VINYL / CARPET
V
IN
YL / C
A
RPET
V
IN
YL / C
A
RPET
C A
RPET / V
IN
YL
VINYL/CARPET
C A
RPET / V
IN
YL
50'-8" (TYPICAL MODULE)
4"3'-1 1/2"5'-6"4'-0 1/2"12'-4"12'-4"
7' -4
" T
YP
IC
A
L M
O D
UL
E
'-8
" T
YP
IC
A
L M
O D
UL
E
'-4
/2
5'
-3
/4
4' -1
/4
2'
-1
4' -0
3' -4
7'
-8
/4
3' -7
/4
3'-6"11'-4 1/2" 4'-1"
3' -0
/2
5'-4"
4'-1 1/2"
1'-0"
6' -4
/2
C A
RPET / V
IN
YL
C A
RPET / V
IN
YL
COMMON AREA
462.6 SF
47 19
CARPET / VINYL
RESTROOM
109.3
77.6 SF
WINDOW SCHEDULE
SYMBOL SIZE TYPE REMARKS
1 8046 DUAL GLAZED, SLIDER BLAST RESISTANT (INCLUDING GI Java)
2 5046 DUAL GLAZED, SLIDER FIELD VERIFY SIZE, BLAST RESISTANT
(INCLUDING GI Java)
NORTH
PROJECT
NORTH
TRUE
NORTH
PROJECT
NORTH
TRUE
DOOR SCHEDULE
SYMBOL SIZE TYPE REMARKS
A 3070 METAL, SOLID CORE 1616 TEMPERED GLAZING, BLAST RESISTANT
B 3070 WOOD, SOLID CORE PAINT GRADE
C 2870 WOOD, SOLID CORE PAINT GRADE
D 8070 TEMPERED GLASS SLIDER (2) FIXED PANELS, (1) SLIDER FIT TO OPENING,
BLAST RESISTANT, AT GI Java
E 6070 FIBERGLASS DOUBLE DOOR MECHANICAL ROOM DOOR ONLY
C
D
5:12
5:12
5:12
5:12
5:12
5:12
5:12
5:125:12
5:12
5:125:12
5:12
D A
TE
D
ES
C
RI
PT
IO
N
O F
RE
V
IS
IO
N
SY
M
BO
L
PROJECT #
SHEET #
DRAWING #
D A
TE
OF
SC
A
LE
D
RA
W
IN
G T
ITL
E
PR
O
JE
C
T
TIT
LE
D
RA
W
N
RE
V
IE
W
ED
D
ES
IG
N
ED
F O
R
O
F F
I C
I A
L
U
L
Y
I N
F O
R M
A T
I O
N
S
A F
E G
U A
R D
I N
G
Q
U I R e i n f o r m a t i o n c o n t a i n e d o n t h i s d r a w i n g s h a l l r e m a i n u n d e r t h e c o n t r o l o f t h e o r i g i n a t i n g r e q u e s t e r o r a g e n c y o r i t s s u c c e s s o r i n f u n c t i o n a t a l l t i m e f o r m a t i o n s a f e g u a r d i n g i s t h e r e s p o n s i b i l i t y o f t h e i n d i v i d u a l a g e n c y c o m p a n y r e q u e s t i n g t h e d a t a a n d t a k i n g o r i g i n a l p o s s e s s i o n o f t h i s d r a w i n l e a s e d i s c l o s u r e o f d a t a t o a n y p a r t y b e y o n d t h e o r i g i n a l r e q u e s t a n d i n t e n d e d u s e i s p r o h i b i t e p u b l i c p u b l i c a t i o n o f t h e d a t a b y a n y m e a n s o r a n a l y s e s t h e r e o f i s a u t h o r i z e o n c o m p l e t i o n o f t h e u s e o f t h e d a t a c o n t a i n e d o n t h i s d r a w i n g t h e d r a w i n g m u s t b e r e t u r n e d o r d e s t r o y e r e c t a n y q u e s t i o n s t o t h e
E n g i n e e r i n g
S u p p o r t
E l e m e n t
C
E S
C
E C
B a t
I n f o r m a t i o n s a f e g u a r d i n g r e q u i r e m e n t s a r e p e r
A
F M
A N
A
F I
D g a n d
E x e c u t i v e
O r d e r w h e n a p p l i c a b l e
D O
N O
T D
U
PL
IC
A
TE
T
H
IS
D R
A W
IN
G
O
R T
H E
D A
TA
C
O N
TA
IN
ED
O
N
IT
09-1253
A102
A pr
A S
N O
TE
D
KR
G
KR
G
KR
G
RE
PA
IR
IN
TE
RI
O R/
EX
TE
RI
O
R O
F D
O
RM
, B
LD
G
FI
RS
T
S
EC
O N
D F
LO
O
R
PL
A N
, B
LD
G
TY
PI
C A
L M
O D
UL
E
FL
O
O R
PL
A
N
ROOF PLAN, BLDG 13321
SCALE: 1/8" = 1'-0"
THIRD FLOOR PLAN, BLDG 13321
SCALE: 1/8" = 1'-0"
REFERENCE NOTES 35
1. REPLACE AND REPAIR ANY (E) CONCRETE ROOF TILES, SUPPORTING STRUCTURE
(i.e. CLEATS) & BUILDING PAPER AS DISCOVERED DURING DEMOLITION
OPERATIONS. INSPECT PLYWOOD SHEATHING FOR ANY DAMAGE AND/OR NEED
TO REPAIR OR REPLACE. TYPICAL AT ALL CONCRETE TILE ROOF AREAS.
2. INSTALL (N) BUILT-UP ROOF AREA AT ALL AREAS WITH BUILT-UP ROOFING TYPICAL;
INSTALL WITH SLOPES AS SHOWN; PROVIDE 1/4" PER FT SLOPE MINIMUM AND
CRICKETS AS SHOWN.
3. PROVIDE ALL FLASHING AND COUNTER FLASHING AS REQUIRED BY CODE AND
RECOMMENDED BY MANUFACTURER.
4. PROVIDE ROOF VENTING AS NEEDED w/ PROPER FLASHING/COUNTER FLASHING
FOR ALL (N) EQUIPMENT IN MECHANICAL ROOM.
5. PROVIDE ALL (N) CONTINUOUS GUTTERS, DOWNSPOUTS, SCUPPERS AND
OVERFLOW SCUPPERS; ALL METALS SHALL BE PRE-FINISHED OR, IF PRE-FINISHED
MATERIAL IS NOT AVAILABLE, PAINTED TO MATCH BUILDING PAINT COLORS.
6. (N) ROOF DRAIN w/ INTEGRAL OVERFLOW INSTALLED AS INDICATED.
7. PROVIDE CHAIN LINK MESH AND SUPPORTING STRUCTURE WITH ADEQUATE
SUPPORT TO ENSURE NO SAGGING INSTALLED HORIZONTALLY OVER EQUIPMENT
ENCLOSURE TO COMPLY WITH CURRENT ANTITERRORISM STANDARDS, UFC
4-010-01 MINIMUM ANTITERRORISM STANDARDS FOR DOD BUILDINGS.
8. APPROXIMATE LOCATION OF VENTILATION HOODS FOR VARIOUS SPACES IN
BUILDING; TYPICAL OF (6) SHOWN; ADDITIONAL VENT HOODS MAY BE REQUIRED;
PROVIDE EQUIPMENT COMPLIANT w/ HVAC STANDARDS ON G001.
9. LOUVERED ATTIC VENTILATION OPENING; SIZE TO BE CALCULATED AS REQUIRED
BY INTERNATIONAL BUILDING CODE; TYPICAL OF (14) SHOWN.
10. 30"w x 36"h ATTIC SPACE ACCESS DOOR; TYPICAL OF (2) SHOWN.
11. REPLACE ALL ROOF ACCESS HATCHES WITH SAME SIZE ACCESS DOORS; FIELD
VERIFY QUANTITY AND LOCATION TYPICAL.
12. REFRIGERATOR (NOT IN CONTRACT); PROVIDE 36"w BY 68"h CLEAR SPACE AS
SHOWN.
13. DRAWER BANK TYPICAL; PROVIDE (4) DRAWERS AS SHOWN.
14. PROVIDE CABINET WITH DOORS AND FIXED DRAWER PANEL AT SINK AREA.
15. PROVIDE CABINET WITH DOORS, FIXED DRAWER PANEL AND FIXED SHELF AT
RANGE AREA.
16. PROVIDE SOLID MATERIAL COUNTERTOP (CORIAN OR EQUIVALENT) AT +36" AFF
TYPICAL WITH MINIMUM 4" BACKSPLASH AT ALL COUNTERTOP AREA TYPICAL.
17. PROVIDE MICROHOOD CONVECTION OVEN COMBINATION; KENMORE ELITE
86013;VENT RANGE HOOD TO SHAFT PROVIDED; PROVIDE MINIMUM CLEARANCE
AS REQUIRED BY MANUFACTURER.
18. PROVIDE FULL OVERHEAD CABINET OVER MICROHOOD CONVECTION OVEN
WITH FIXED SHELF AS SHOWN; SIZE ACCORDING TO REQUIRED CLEARANCES AND
MINIMUM DUCT SIZING FOR HOOD.
19. PROVIDE FULL OVERHEAD CABINET WITH FIXED SHELF OVER SINK AREA WITH
BUILT-IN CONCEALED LIGHT FIXTURE UNDER CABINET; PROVIDE MINIMUM
CLEARANCE.
20. PROVIDE FULL OVERHEAD CABINET WITH (2) FIXED SHELVES AS SHOWN TYPICAL;
B.O. OF CABINET AT +18" ABOVE COUNTERTOP TYPICAL.
21. PROVIDE FULL OVERHEAD CABINET AS SHOWN TYPICAL; SIZE SET BY CLEARANCES
REQUIRED BY REFRIGERATOR (SEE NOTE 12).
22. OPEN TO BEYOND.
23. PROVIDE (3) EQUAL CABINETS WITH FIXED SHELF OVER AREA FOR WASHER AND
DRYER; SET BOTTOM OF CABINETS AT MINIMUM OF 68" AFF TYPICAL.
24. PROVIDE CABINET WITH DOOR AND DRAWER AS SHOWN TYPICAL.
25. WASHER AND DRYER (NOT IN CONTRACT); PROVIDE MINIMUM 60" CLEAR AREA
AS SHOWN.
26. 36" x 48" FIBERGLASS SHOWER PAN WITH CERAMIC TILE SURROUND AND
TEMPERED GLASS SHOWER ENCLOSURE; SHOWER CURB TO BE A MINIMUM OF 4"
TYPICAL; SEE FLOOR PLAN FOR ADDITIONAL INFORMATION.
27. DRAWER BANK TYPICAL; PROVIDE (3) DRAWERS AS SHOWN.
28. PROVIDE CABINET WITH DOOR AND FIXED DRAWER PANEL AT SINK AREA.
29. PROVIDE A FULL WIDTH MIRROR ABOVE THE VANITY, WITH TOP OF MIRROR A
MINIMUM OF 72" ABOVE THE FINISH FLOOR; BOTTOM OF THE MIRROR SHALL
EXTEND TO THE TOP OF THE BACK SPLASH.
30. PROVIDE SOLID MATERIAL COUNTERTOP (CORIAN OR EQUIVALENT) AT +30" AFF
TYPICAL WITH MINIMUM 4" BACKSPLASH AT ALL COUNTERTOP AREA TYPICAL.
31. LOW FLOW TOILET TYPICAL; SEE FLOOR PLAN FOR ADDITIONAL INFORMATION.
KEY PLAN 65
13123
13121
0 13
SCALE: NOT TO SCALE
NORTH
PROJECT
SEE TYPICAL MODULE FLOOR PLAN FOR
TYPICAL NOTES. ALL NOTES SHOWN ON THIS
DRAWING ARE NOT TYPICAL.
SEE TYPICAL MODULE FLOOR PLAN FOR
TYPICAL NOTES. ALL NOTES SHOWN ON THIS
DRAWING ARE NOT TYPICAL.
TYPICAL NOTES 55
A. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL COMPLY WITH REQUIREMENTS AS
OUTLINED IN UFC 4-010-01/02 MINIMUM ANTITERRORISM STANDARDS FOR DOD
BUILDINGS.
B. PROVIDE APPROPRIATE HVAC SYSTEM AS REQUIRED PER THE FOLLOWING:
-- UFC 3-400-01 ENERGY CONSERVATION
-- UFC 3-401-01FA UTILITY MONITORING & CONTROL SYSTEMS
-- UFC 3-410-01FA HVAC
-- ETL 04-3 : DESIGN CRITERIA FOR PREVENTION OF MOLD IN AF FACILITIES
-- UNACCOMPANIED HOUSING GUIDE, US AIR FORCE
C. SEE FINISH, DOOR AND WINDOW SCHEDULES FOR ADDITIONAL INFORMATION.
D. INSTALL SPRINKLER FIRE PROTECTION SYSTEM THROUGHOUT FACILITY COMPLIANT
WITH NFPA REQUIREMENTS.
E. CONTRACTOR SHALL PATCH AND REPAIR ALL CONCRETE SLABS TO BE
STRUCTURALLY SOUND WHERE (E) UTILITY CHASES ARE REMOVED AND NOT USED.
F. ALL NEW COMMUNICATIONS WIRING, PANELS AND EQUIPMENT TO INCLUDE
TELEVISION CABLE, TELEPHONE, WI-FI WIRING AND ALARM PANEL WIRING SHALL
MEET CURRENT STANDARDS AS DETERMINED BY 30 SPACE COMMUNICATIONS
SQUADRON.
G. ALL INTERIOR WALLS AND INFILL PANELS SHALL CONTAIN A MINIMUM OF R-19
SOUND INSULATION TYPICAL.
42SCHEMATIC INTERIOR ELEVATIONS
SCALE: 1/4" = 1'-0"
KITCHEN AND LAUNDRY (TYPICAL) BATHROOM - 209A BATHROOM - 209B
(209D SIMILAR) (209C SIMILAR)
BEDROOM
310A
169.4 SF
BEDROOM
310B
164.7 SF
BEDROOM
310C
164.7 SF
BEDROOM
310D
169.4 SFKITCHEN
LAUNDRY
BATH
BATH
BATH
BATH BATH
BATHBATH
BATH
KITCHEN
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
BEDROOM
309A
169.4 SF
BEDROOM
309B
164.7 SF
BEDROOM
309C
164.7 SF
BEDROOM
309D
169.4 SF
PATIO PATIO
LAUNDRY
COMMON AREA
462.6 SF
COMMON AREA
462.6 SF
A301
A301
5 5
A301
A301
NORTH
PROJECT
NORTH
TRUE
NORTH
PROJECT
NORTH
TRUE
26 27 2728 28 26
31 3112 13 14 15
C E J L NF G M
SR
A
FGM ABDHKP
S R Q
B
O
M
A
R
C
643 521 9
D A
TE
D
ES
C
RI
PT
IO
N
O F
RE
V
IS
IO
N
SY
M
BO
L
PROJECT #
SHEET #
DRAWING #
D A
TE
OF
SC
A
LE
D
RA
W
IN
G T
ITL
E
PR
O
JE
C
T
TIT
LE
D
RA
W
N
RE
V
IE
W
ED
D
ES
IG
N
ED
F O
R
O
F F
I C
I A
L
U
L
Y
I N
F O
R M
A T
I O
N
S
A F
E G
U A
R D
I N
G
Q
U I R e i n f o r m a t i o n c o n t a i n e d o n t h i s d r a w i n g s h a l l r e m a i n u n d e r t h e c o n t r o l o f t h e o r i g i n a t i n g r e q u e s t e r o r a g e n c y o r i t s s u c c e s s o r i n f u n c t i o n a t a l l t i m e f o r m a t i o n s a f e g u a r d i n g i s t h e r e s p o n s i b i l i t y o f t h e i n d i v i d u a l a g e n c y c o m p a n y r e q u e s t i n g t h e d a t a a n d t a k i n g o r i g i n a l p o s s e s s i o n o f t h i s d r a w i n l e a s e d i s c l o s u r e o f d a t a t o a n y p a r t y b e y o n d t h e o r i g i n a l r e q u e s t a n d i n t e n d e d u s e i s p r o h i b i t e p u b l i c p u b l i c a t i o n o f t h e d a t a b y a n y m e a n s o r a n a l y s e s t h e r e o f i s a u t h o r i z e o n c o m p l e t i o n o f t h e u s e o f t h e d a t a c o n t a i n e d o n t h i s d r a w i n g t h e d r a w i n g m u s t b e r e t u r n e d o r d e s t r o y e r e c t a n y q u e s t i o n s t o t h e
E n g i n e e r i n g
S u p p o r t
E l e m e n t
C
E S
C
E C
B a t
I n f o r m a t i o n s a f e g u a r d i n g r e q u i r e m e n t s a r e p e r
A
F M
A N
A
F I
D g a n d
E x e c u t i v e
O r d e r w h e n a p p l i c a b l e
D O
N O
T D
U
PL
IC
A
TE
T
H
IS
D R
A W
IN
G
O
R T
H E
D A
TA
C
O N
TA
IN
ED
O
N
IT
09-1253
A201
A pr
A S
N O
TE
D
KR
G
KR
G
KR
G
RE
PA
IR
IN
TE
RI
O R/
EX
TE
RI
O
R O
F D
O
RM
, B
LD
G
EX
TE
RI
O
R
EL
EV
A
TIO
N
S, B
LD
G
NORTH ELEVATION, BLDG 13323
SCALE: 1/8" = 1'-0"
REFERENCE NOTES 15
SOUTH ELEVATION, BLDG 13323
SCALE: 1/8" = 1'-0"
1. INSTALL (N) DOORS, FRAMES, HARDWARE & WINDOWS; SEE FLOOR PLANS FOR
ADDITIONAL INFORMATION.
2. PAINT ALL HANDRAILS, GUARDRAILS AND METAL COLUMNS AT BALCONIES AFTER
CLEANING AND SANDBLASTING.
3. INSTALL (N) FLASHING & COUNTERFLASHING AT ALL (N) OPENINGS (DOORS,
WINDOWS) AND ALL AREAS APPROPRIATE FOR WATER PROOFING TYPICAL.
4. INSTALL (N) ROOF DRAINS, GUTTERS, PIPES & SPLASH BLOCKS TYPICAL.
5. REPLACE AND REPAIR ANY (E) CONCRETE ROOF TILES, SUPPORTING STRUCTURE (i.e.
CLEATS) & BUILDING PAPER AS DISCOVERED DURING DEMOLITION OPERATIONS.
INSPECT PLYWOOD SHEATHING FOR ANY DAMAGE AND/OR NEED TO REPAIR OR
REPLACE. TYPICAL AT ALL CONCRETE TILE ROOF AREAS.
6. CLEAN ALL CONCRETE FLOOR SURFACES AT BALCONIES, STAIR RISERS & TREADS.
7. INSTALL (N) WALL MTD. & CEILING MTD. LIGHT FIXTURES AT EXTERIOR OF BUILDING
AND STAIRS IN AREAS WHERE REMOVED. FIELD VERIFY LOCATION & COORDINATE
REMO…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .