PM Instructions
| PMI TITLE | PMI # | FREQ | STEP # | PM INSTRUCTIONS |
| ABOVE GROUND STORAGE TANK | PM050007 | 0 | 0 | Have spill kit and absorbent pads readily available. |
| ABOVE GROUND STORAGE TANK | PM050007 | 2000003 | 1 | Check for signs of corrosion or leakage on tank exterior, inlet piping, |
| ABOVE GROUND STORAGE TANK | PM050007 | 2000003 | 1 | valves, connections and outlet piping. |
| ABOVE GROUND STORAGE TANK | PM050007 | 2000003 | 2 | Ensure equipment is in working order. Check vavles and connections on |
| ABOVE GROUND STORAGE TANK | PM050007 | 2000003 | 2 | inlet and outlet piping. |
| ABOVE GROUND STORAGE TANK | PM050007 | 2000003 | 3 | Check for cracks or deterioration on secondary containment |
| ABOVE GROUND STORAGE TANK | PM050007 | 2000003 | 4 | Ensure secondary containment is secured, closed and locked |
| ABOVE GROUND STORAGE TANK | PM050007 | 2000003 | 5 | Check for presence of material in annular spacing for double walled tanks. |
| ABOVE GROUND STORAGE TANK | PM050007 | 2000003 | 6 | Check secondary containment for accumulated liquids (POL or water). If |
| ABOVE GROUND STORAGE TANK | PM050007 | 2000003 | 6 | water is present check for oil sheen. Remove and oil sheen with absorbent |
| ABOVE GROUND STORAGE TANK | PM050007 | 2000003 | 6 | pads and dispose as hazardous waste. Drain water. Notify Environmental. |
| ABOVE GROUND STORAGE TANK | PM050007 | 2000003 | 7 | Ensure high-liquid level alarm and cut-off switch are functioning |
| ABOVE GROUND STORAGE TANK | PM050007 | 2000003 | 7 | properly. |
| ABOVE GROUND STORAGE TANK | PM050007 | 2000003 | 8 | Ensure hazardous material in tank is compatible with tank material. |
| ABOVE GROUND STORAGE TANK | PM050007 | 2000003 | 9 | Ensure that the tank and associated piping are labeled with tank contents |
| ABOVE GROUND STORAGE TANK | PM050007 | 2000003 | 10 | Ensure pumps and valves are vapor tight |
| ACCELEROGRAPH | PM040002 | 3000001 | 1 | Notify Facility Manager and all relevant authorities, (E.G. Fire Dept.), |
| ACCELEROGRAPH | PM040002 | 3000001 | 1 | when applicable, of work to be accomplished. |
| ACCELEROGRAPH | PM040002 | 3000001 | 2 | VERIFY BARCODE IS ATTACHED AND CORRECT |
| ACCELEROGRAPH | PM040002 | 3000001 | 3 | REMOVE EXCESS, UNAUTHORIZED OR UNSAFE STORED MATERIALS |
| ACCELEROGRAPH | PM040002 | 3000001 | 4 | CHECK ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC. |
| ACCELEROGRAPH | PM040002 | 3000001 | 5 | TIGHTEN TERMINALS & RESEAT CONNECTORS AS REQUIRED |
| ACCELEROGRAPH | PM040002 | 3000001 | 6 | CLEAN EXTERIOR OF UNIT |
| ACCELEROGRAPH | PM040002 | 3000001 | 7 | Notify Facility Manager and all relevant authorities, (E.G. Fire Dept.), |
| ACCELEROGRAPH | PM040002 | 3000001 | 7 | when applicable, of work accomplished and any pertinent information |
| ACCELEROGRAPH | PM040002 | 3000001 | 7 | regarding facility. |
| ACCELEROGRAPH | PM040002 | 3000001 | 8 | Notify Work Control Center of any follow up required. |
| AGITATOR | PM040008 | 2000001 | 1 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AGITATOR | PM040008 | 2000001 | 1 | etc.), when applicable, of work to be accomplished. |
| AGITATOR | PM040008 | 2000001 | 2 | CHANGE OIL IN GEAR BOX |
| AGITATOR | PM040008 | 2000001 | 3 | CHECK OIL LEVEL AND TOP OFF OR DRAIN & REPLACE |
| AGITATOR | PM040008 | 2000001 | 4 | TAKE COUPLINGS APART AND CLEAN/GREASE |
| AGITATOR | PM040008 | 2000001 | 5 | LUBRICATE LINKAGES AND BEARINGS AS NEEDED |
| AGITATOR | PM040008 | 2000001 | 6 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AGITATOR | PM040008 | 2000001 | 6 | etc), when applicable, of work accomplished and any pertinent information |
| AGITATOR | PM040008 | 2000001 | 6 | regarding the facility. |
| AGITATOR | PM040008 | 2000001 | 7 | Notify Work Control Center of any follow up required |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 1 | NOTIFY FACILITY MANAGER AND ALL RELEVANT AUTHORITIES (E.G. FIRE DEPT, |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 1 | ETC.), WHEN APPLICABLE, OF WORK TO BE ACCOMPLISHED. |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 2 | UNPLUG UNIT TO REMOVE POWER |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 3 | CLEAN EXTERIOR OF UNIT |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 4 | CLEAN OR REPLACE FILTERS, SCREENS, SEPARATORS.ETC |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 5 | IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 6 | CHECK ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC. |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 7 | TIGHTEN TERMINALS & CONNECTIONS AS REQ'D |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 8 | INSPECT LATCHES, COUPLINGS, CONTROLS, SWITCHES, ETC |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 9 | LUBRICATE MOVING PARTS |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 10 | IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 11 | INSPECT THE UNIT FOR AIR LEAKS |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 12 | REPAIR OR REPLACE DEFECTIVE PARTS AS NECESSARY |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 13 | ACTIVATE CONTROLLED SHUTDOWN |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 14 | NOTIFY FACILITY MANAGER AND ALL RELEVANT AUTHORITIES (E.G. FIRE DEPT, |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 14 | ETC.), WHEN APPLICABLE, OF WORK ACCOMPLISHED AND ANY PERTINENT |
| AIR BOTTLE CHARGER | PM040001 | 3000001 | 14 | INFORMATION REGARDING THE FACILITY. |
| AIR COMPRESSOR | PM040004 | 2000001 | 1 | Notify Facility Manager and all relevant authorities, (E.G. Fire Dept.), |
| AIR COMPRESSOR | PM040004 | 2000001 | 1 | when applicable, of work to be accomplished. |
| AIR COMPRESSOR | PM040004 | 2000001 | 2 | POWER OFF UNIT, LOCKOUT AND TAGOUT DISCONNECT |
| AIR COMPRESSOR | PM040004 | 2000001 | 3 | CLEAN EXTERIOR OF UNIT |
| AIR COMPRESSOR | PM040004 | 2000001 | 4 | DRAIN CONDENSATE LIQUID FROM TANK |
| AIR COMPRESSOR | PM040004 | 2000001 | 5 | CHECK ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC. |
| AIR COMPRESSOR | PM040004 | 2000001 | 6 | TIGHTEN TERMINALS & RESEAT CONNECTORS AS REQUIRED |
| AIR COMPRESSOR | PM040004 | 2000001 | 7 | ADJUST CONTROL SETTINGS AS REQUIRED |
| AIR COMPRESSOR | PM040004 | 2000001 | 8 | CLEAN OR REPLACE INTAKE AIR CLEANER |
| AIR COMPRESSOR | PM040004 | 2000001 | 9 | DRAIN AND CLEAN OIL / WATER TRAPS |
| AIR COMPRESSOR | PM040004 | 2000001 | 10 | INSPECT PIPING, FITTINGS, VALVES, ETC FOR DAMAGE AND LEAKS |
| AIR COMPRESSOR | PM040004 | 2000001 | 11 | INSPECT SAFETY VALVES, PRESS. REGULATORS & OUTPUT AIR FLTRS |
| AIR COMPRESSOR | PM040004 | 2000001 | 12 | CHECK DRIVE TRAIN ALIGNMENT, TENSION AND WEAR |
| AIR COMPRESSOR | PM040004 | 2000001 | 13 | ADJUST BELT OR CHAIN TENSION/ALIGNMENT AS REQUIRED |
| AIR COMPRESSOR | PM040004 | 2000001 | 14 | INSPECT ALL VISIBLE MOVING PARTS FOR DEFECTS. REPORT FINDINGS. |
| AIR COMPRESSOR | PM040004 | 2000001 | 15 | CLEAN OR REPLACE FILTER MEDIUM OR ELEMENTS, AS REQUIRED |
| AIR COMPRESSOR | PM040004 | 2000001 | 16 | LUBRICATE MOTOR & SHAFT BEARINGS |
| AIR COMPRESSOR | PM040004 | 2000001 | 17 | IN ACCORDANCE WITH MANUFACTERES RECOMMENDATIONS |
| AIR COMPRESSOR | PM040004 | 2000001 | 18 | CHECK OIL LEVEL AND TOP OFF OR DRAIN & REPLACE |
| AIR COMPRESSOR | PM040004 | 2000001 | 19 | REMOVE LOCKOUT AND RESTORE POWER TO UNIT |
| AIR COMPRESSOR | PM040004 | 2000001 | 20 | IF EQUIPPED WITH INLINE VALVE, CLOSE INLINE VALVE JUST PAST |
| AIR COMPRESSOR | PM040004 | 2000001 | 21 | COMPRESSORS AND MONITOR PRESSURE GAUGE, IF THERE IS A SIGNIFICANT |
| AIR COMPRESSOR | PM040004 | 2000001 | 22 | DROP IN PRESSSURE, OPEN WORK ORDER TO CHECK SYSTEM FOR LEAKS |
| AIR COMPRESSOR | PM040004 | 2000001 | 23 | Notify Facility Manager and all relevant authorities, (E.G. Fire Dept.), |
| AIR COMPRESSOR | PM040004 | 2000001 | 23 | when applicable, of work accomplished and any pertinent information |
| AIR COMPRESSOR | PM040004 | 2000001 | 23 | regarding facility. |
| AIR COMPRESSOR | PM040004 | 2000001 | 24 | Notify Work Control Center of any follow up required. |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000001 | 1 | Notify Facility Manager and all relevant authorities, (E.G. Fire Dept.), |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000001 | 1 | when applicable, of work to be accomplished. |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000001 | 2 | DISCONNECT UNIT FROM POWER, LOCKOUT AND TAG-OUT. |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000018 | 3 | REPLACE FILTER MEDIUM OR ELEMENTS |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000001 | 4 | CHECK AND ENSURE THAT RETURN AIR IS FREE OF ANY OBSTRUCTION |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000001 | 5 | CHECK THE CONDITION OF THE FILTERS |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000003 | 6 | CLEAN FAN, FAN BLADES, & MOTOR VENT AS REQUIRED |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000003 | 7 | CHECK AND ENSURE THAT CABINET, COILS, DRIP PANS & DRAINS, ETC. ARE FREE OF |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000003 | 7 | DUST OR DEBRIS OR ANY OBSTRUCTIONS |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 3000001 | 8 | REPLACE DRIVE BELTS (If available on the unit) |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000003 | 9 | CHECK ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC. |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000003 | 10 | TIGHTEN TERMINALS & CONNECTIONS AS REQ'D |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000003 | 11 | LUBRICATE MOTOR & SHAFT BEARINGS |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000001 | 12 | REMOVE LOCKOUT AND RESTORE POWER TO UNIT |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000001 | 13 | RUN THE UNIT AND OBSERVE FOR PROPER OPERATION |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000003 | 14 | CHECK FOR NORMAL OPERATION, SUCTION & HEAD PRESSURE |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000003 | 15 | ADD REFRIGERANT AS NEEDED. RECORD AMOUNT REQUIRED |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000001 | 16 | Notify Facility Manager and all relevant authorities, (E.G. Fire Dept.), |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000001 | 16 | when applicable, of work accomplished and any pertinent information |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000001 | 16 | regarding facility. |
| AIR CONDITION UNIT (PACKAGE/CRAC) | PM040005 | 2000001 | 17 | Notify Work Control Center of any follow up required. |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 1 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 1 | etc.), when applicable, of work to be accomplished. |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 2 | POWER OFF UNIT, LOCKOUT AND TAGOUT DISCONNECT |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 3 | INSPECT LATCHES, COUPLINGS, CONTROLS, SWITCHES, ETC |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 4 | INSPECT ALL MOTOR STARTER CONTACT POINTS |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 5 | INSPECT CONDITION OF BELTS, PULLEYS, ETC. |
| AIR COOLED CONDENSING UNIT | PM040040 | 3000001 | 6 | REPLACE DRIVE BELTS |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000003 | 7 | RELPACE FILTER ELEMENTS, IF EQU'P |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 8 | INSPECT PIPING, FITTINGS, VALVES, ETC FOR DAMAGE AND LEAKS |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 9 | CHECK ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC. |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 10 | CLEAN CONDENSOR/WATER COILS |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 11 | CLEAN FAN, FAN BLADES, & MOTORS AS REQUIRED |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 12 | TIGHTEN, REPAIR OR REPLACE AS NECESSARY |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 13 | CHECK ROTATIONAL BALANCE, REBALANCE IF NECESSARY |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 14 | ADD REFRIGERANT AS NEEDED. RECORD AMOUNT REQUIRED |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 15 | REPAIR OR REPLACE DEFECTIVE PARTS AS NECESSARY |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 16 | MEASURE & RECORD OPERATING SUPPLY VOLTAGE & CURRENT |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 17 | MEASURE & RECORD OPERATING PRESSURE & TEMP. |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 18 | RESTORE POWER TO THE UNIT AND VERIFY PROPER OPERATION |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 19 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 19 | etc), when applicable, of work accomplished and any pertinent information |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 19 | regarding the facility. |
| AIR COOLED CONDENSING UNIT | PM040040 | 2000001 | 20 | Notify Work Control Center of any follow up required. |
| AIR CURTAIN | PM040142 | 3000001 | 1 | POWER OFF UNIT, LOCKOUT AND TAGOUT DISCONNECT |
| AIR CURTAIN | PM040142 | 3000001 | 2 | CHECK OPERATION OF AUTOMATIC DOOR SWITCH (IF EQUIPPED) |
| AIR CURTAIN | PM040142 | 3000001 | 3 | CLEAN HOUSING, FAN, FAN MOTOR, ETC. (IF EQUIPPED) |
| AIR CURTAIN | PM040142 | 3000001 | 4 | INSPECT FOR RUST, CORROSION, CRACKS, PINHOLES, ETC. |
| AIR CURTAIN | PM040142 | 3000001 | 5 | REPAIR OR REFINISH, AS REQUIRED |
| AIR CURTAIN | PM040142 | 3000001 | 6 | CHECK ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC. |
| AIR CURTAIN | PM040142 | 3000001 | 7 | TIGHTEN TERMINALS & CONNECTIONS AS REQ'D |
| AIR CURTAIN | PM040142 | 3000001 | 8 | LUBRICATE LINKAGES AND BEARINGS AS NEEDED |
| AIR CURTAIN | PM040142 | 3000001 | 9 | RESTORE POWER TO THE UNIT AND VERIFY PROPER OPERATION |
| AIR CURTAIN | PM040142 | 3000001 | 10 | ADJUST / STRAIGHTEN VANES, LINKS, & LOUVERS AS REQD |
| AIR DRYER | PM040099 | 2000006 | 1 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AIR DRYER | PM040100 | 2000006 | 1 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AIR DRYER | PM040099 | 2000006 | 1 | etc.), when applicable, of work to be accomplished. |
| AIR DRYER | PM040100 | 2000006 | 1 | etc.), when applicable, of work to be accomplished |
| AIR DRYER | PM040099 | 2000006 | 2 | CHECK FOR EXCESSIVE NOISE OR VIBRATION |
| AIR DRYER | PM040100 | 2000006 | 2 | POWER OFF UNIT, LOCKOUT AND TAGOUT DISCONNECT |
| AIR DRYER | PM040099 | 2000006 | 3 | POWER OFF UNIT, LOCKOUT AND TAGOUT DISCONNECT |
| AIR DRYER | PM040100 | 2000006 | 3 | CHECK MOTORS, BEARINGS, ETC FOR OVERHEATING |
| AIR DRYER | PM040099 | 2000006 | 4 | CHECK MOTORS, BEARINGS, ETC FOR OVERHEATING |
| AIR DRYER | PM040100 | 2000006 | 4 | DRAIN AND CLEAN OIL / WATER TRAPS |
| AIR DRYER | PM040099 | 2000006 | 5 | DRAIN AND CLEAN OIL / WATER TRAPS |
| AIR DRYER | PM040100 | 2000006 | 5 | CLEAN CONDENSOR/WATER COILS |
| AIR DRYER | PM040099 | 2000006 | 6 | CLEAN CONDENSOR/WATER COILS |
| AIR DRYER | PM040100 | 2000006 | 6 | CLEAN OR REPLACE FILTER MEDIUM OR ELEMENTS, AS REQ'D (IF EQP |
| AIR DRYER | PM040099 | 2000006 | 7 | CLEAN OR REPLACE FILTER MEDIUM OR ELEMENTS, AS REQ'D (IF EQP |
| AIR DRYER | PM040100 | 2000006 | 7 | CLEAN FAN, FAN BLADES, & MOTORS AS REQUIRED |
| AIR DRYER | PM040099 | 2000006 | 8 | CLEAN FAN, FAN BLADES, & MOTORS AS REQUIRED |
| AIR DRYER | PM040100 | 2000006 | 8 | INSPECT PIPING, FITTINGS, VALVES, ETC FOR DAMAGE AND LEAKS |
| AIR DRYER | PM040099 | 2000006 | 9 | INSPECT PIPING, FITTINGS, VALVES, ETC FOR DAMAGE AND LEAKS |
| AIR DRYER | PM040100 | 2000006 | 9 | CHECK ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC. |
| AIR DRYER | PM040099 | 2000006 | 10 | CHECK ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC. |
| AIR DRYER | PM040100 | 2000006 | 10 | TIGHTEN TERMINALS & CONNECTIONS AS REQ'D |
| AIR DRYER | PM040099 | 2000006 | 11 | TIGHTEN TERMINALS & CONNECTIONS AS REQ'D |
| AIR DRYER | PM040100 | 2000006 | 11 | REPAIR OR REPLACE DEFECTIVE PARTS AS NECESSARY |
| AIR DRYER | PM040099 | 2000006 | 12 | REPAIR OR REPLACE DEFECTIVE PARTS AS NECESSARY |
| AIR DRYER | PM040100 | 2000006 | 12 | LUBRICATE MOVING PARTS |
| AIR DRYER | PM040099 | 2000006 | 13 | LUBRICATE MOVING PARTS |
| AIR DRYER | PM040100 | 2000006 | 13 | IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS |
| AIR DRYER | PM040099 | 2000006 | 14 | IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS |
| AIR DRYER | PM040100 | 2000006 | 14 | RESTORE POWER TO THE UNIT AND VERIFY PROPER OPERATION |
| AIR DRYER | PM040099 | 2000006 | 15 | RESTORE POWER TO THE UNIT AND VERIFY PROPER OPERATION |
| AIR DRYER | PM040100 | 2000006 | 15 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AIR DRYER | PM040100 | 2000006 | 15 | etc), when applicable, of work accomplished and any pertinent information |
| AIR DRYER | PM040100 | 2000006 | 15 | regarding the facility. |
| AIR DRYER | PM040099 | 2000006 | 16 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AIR DRYER | PM040100 | 2000006 | 16 | Notify Work Control Center of any follow up required. |
| AIR DRYER | PM040099 | 2000006 | 16 | etc), when applicable, of work accomplished and any pertinent information |
| AIR DRYER | PM040099 | 2000006 | 16 | regarding the facility. |
| AIR DRYER | PM040099 | 2000006 | 17 | Notify Work Control Center of any follow up required. |
| AIR DRYER | PM040100 | 2000006 | 17 | VERIFY CONTROLS, SWITCHES, ETC. ARE OPERATING PROPELY |
| AIR DRYER | PM040099 | 2000006 | 18 | VERIFY CONTROLS, SWITCHES, ETC. ARE OPERATING PROPELY |
| AIR FILTER | PM040139 | 2000003 | 1 | RESTORE POWER TO THE UNIT AND VERIFY PROPER OPERATION |
| AIR FILTER | PM040139 | 2000003 | 2 | CHECK CONTROLS, DAMPERS, GAUGES ETC |
| AIR FILTER | PM040139 | 2000003 | 3 | INSPECT THE UNIT FOR AIR LEAKS |
| AIR FILTER | PM040139 | 2000003 | 4 | CLEAN OR REPLACE FILTER MEDIUM OR ELEMENTS, AS REQUIRED |
| AIR FILTER | PM040139 | 2000003 | 5 | RESTORE POWER TO THE UNIT AND VERIFY PROPER OPERATION |
| AIR HANDLING UNIT | PM040011 | 2000001 | 1 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AIR HANDLING UNIT | PM040011 | 2000001 | 1 | etc.), when applicable, of work to be accomplished. |
| AIR HANDLING UNIT | PM040011 | 2000001 | 2 | POWER OFF UNIT, LOCKOUT AND TAGOUT DISCONNECT |
| AIR HANDLING UNIT | PM040011 | 2000001 | 3 | INSPECT CONDITION OF BELTS, PULLEYS, ETC. |
| AIR HANDLING UNIT | PM040011 | 3000001 | 4 | REPLACE DRIVE BELTS |
| AIR HANDLING UNIT | PM040011 | 2000001 | 5 | INSPECT CONDITION OF DUCTS, PANELS, HOUSINGS, ETC. |
| AIR HANDLING UNIT | PM040011 | 2000001 | 6 | CHECK LATCHES, HINGES, FASTENERS, ETC. ADJUST AS NECESSARY |
| AIR HANDLING UNIT | PM040011 | 3000001 | 7 | REPLACE FILTER MEDIUM OR ELEMENTS |
| AIR HANDLING UNIT | PM040011 | 2000001 | 8 | CLEAN CABINET INTERIOR AND EXTERIOR WALLS |
| AIR HANDLING UNIT | PM040011 | 2000001 | 9 | INSPECT CONDITION OF COILS, DRIP PANS, DRAINS, ETC.. CLEAN AS NECESSARY W/ |
| AIR HANDLING UNIT | PM040011 | 2000001 | 9 | APPROVED CLEANSER |
| AIR HANDLING UNIT | PM040011 | 2000001 | 10 | INSPECT CONDENSATE DRAINS AND REMOVE ANY OBSTRUCTIONS |
| AIR HANDLING UNIT | PM040011 | 2000001 | 11 | REMOVE LOCKOUT AND RESTORE POWER TO UNIT |
| AIR HANDLING UNIT | PM040011 | 2000001 | 12 | CHECK FOR EXCESSIVE NOISE/VIBRATION |
| AIR HANDLING UNIT | PM040011 | 2000003 | 13 | RECORD VIBRATION AT DESIGNATED/RELEVANT TARGETS (IF APPLICABLE) |
| AIR HANDLING UNIT | PM040011 | 2000001 | 14 | ADJUST BELT OR CHAIN TENSION/ALIGNMENT TO SPECS, AS NECESSARY |
| AIR HANDLING UNIT | PM040011 | 2000003 | 15 | PERFORM IR SCAN OF ALL ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC., |
| AIR HANDLING UNIT | PM040011 | 2000003 | 15 | AND ALL MOVING PARTS. RECORD IMAGES (IF APPLICABLE) |
| AIR HANDLING UNIT | PM040011 | 2000001 | 16 | TIGHTEN TERMINALS & CONNECTIONS AS REQ'D |
| AIR HANDLING UNIT | PM040011 | 2000001 | 17 | CHECK DUCTS/PIPING FOR LEAKS, SCAN WITH IR CAMERA AS REQ'D |
| AIR HANDLING UNIT | PM040011 | 2000001 | 18 | LUBRICATE MOTOR and SHAFT BEARINGS (Pillow or Flange Type) AS NEEDED AND |
| AIR HANDLING UNIT | PM040011 | 2000001 | 18 | IN ACCORDANCE TO MFR'S RECOMMENDATIONS |
| AIR HANDLING UNIT | PM040011 | 2000001 | 19 | REPAIR OR REPLACE DEFECTIVE PARTS AS NECESSARY |
| AIR HANDLING UNIT | PM040011 | 2000003 | 20 | CHECK CONTROLS, DAMPERS. VERIFY INTAKE/EXHAUST LOUVERS OPERATE FROM 0% |
| AIR HANDLING UNIT | PM040011 | 2000003 | 20 | (SHUT) TO 100% (OPEN). MANUALLY OPERATE IF APPLICABLE. ALSO CLEAN, ADJUST |
| AIR HANDLING UNIT | PM040011 | 2000003 | 20 | AND LUBRICATE AS REQUIRED. |
| AIR HANDLING UNIT | PM040011 | 2000001 | 21 | PERFORM VISUAL INSPECTION FOR CORROSION, STRUCTURAL INTEGRITY AND |
| AIR HANDLING UNIT | PM040011 | 2000001 | 21 | SURROUNDINGS OF THE UNIT. NOTE ANY ABNORMALITIES ON THE CRAFT COMMENTS AND |
| AIR HANDLING UNIT | PM040011 | 2000001 | 21 | INFORM YOUR LEAD OR WORK CONTROL CENTER IMMEDIATELY FOR CORRECTIVE ACTION |
| AIR HANDLING UNIT | PM040011 | 2000001 | 22 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AIR HANDLING UNIT | PM040011 | 2000001 | 22 | etc), when applicable, of work accomplished and any pertinent information |
| AIR HANDLING UNIT | PM040011 | 2000001 | 22 | regarding the facility. |
| AIR HANDLING UNIT | PM040011 | 2000001 | 23 | Notify Work Control Center of any follow up required. |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 1 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 1 | etc.), when applicable, of work to be accomplished |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 2 | POWER OFF UNIT, LOCKOUT AND TAGOUT DISCONNECT |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 3 | CHECK ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC. |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 4 | BLOW CLEAN INT. OF ELECTRONICS TO REMOVE DUST AND LINT |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 5 | TIGHTEN TERMINALS & RESEAT CONNECTORS AS REQUIRED |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 6 | CLEAN OR REPLACE FILTER MEDIUM OR ELEMENTS, AS REQUIRED |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 7 | CLEAN HOUSING, FAN, FAN MOTOR, ETC. (IF EQUIPPED) |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 8 | REPAIR OR REPLACE DEFECTIVE PARTS AS NECESSARY |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 9 | LUBRICATE MOTOR & SHAFT BEARINGS |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 10 | IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 11 | REMOVE LOCKOUT AND RESTORE POWER TO UNIT |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 12 | MEASURE & RECORD POWER SUPPLY INPUT & OUTPUT VOLTAGES |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 13 | MEASURE & RECORD AIR FLOW TEMPERATURE & VELOCITY |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 14 | ADJUST AS REQUIRED |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 15 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 15 | etc), when applicable, of work accomplished and any pertinent information |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 15 | regarding the facility. |
| AIR PURIFICATION UNIT | PM040015 | 2000006 | 16 | Notify Work Control Center of any follow up required. |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 0 | 0 | HIGH HAZARD UNITS WILL BE TESTED EVERY 6 MONTHS IN COMPLIANCE WITH |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 0 | 0 | 30SW132-1066. |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 1 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 1 | etc.), when applicable, of work to be accomplished. |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 2 | NOTIFY USERS OF PLANNED WATER SYSTEM SHUTOFF |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 3 | INSPECT THE UNIT FOR WATER LEAKS |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 4 | INSPECT FOR RUST, CORROSION, CRACKS, PINHOLES, ETC. |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 5 | BACKFLOW DEVICES MUST BE TESTED BY A CERTIFIED PERSON USING AN APPROVED |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 5 | TESTING DEVICE (COMPLIANCE TO AFPD 32-10, supercedes AFI 32-1066) |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 6 | If unit is found not functioning properly, dissassemble unit, clean and |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 6 | inspect all parts. Reaasemble and retest as applicable. |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 7 | CLEAN OR REPLACE STRAINERS AS REQUIRED, WHEN APPLICABLE |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 8 | REPAIR OR REPLACE DEFECTIVE PARTS AS NECESSARY |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 9 | RESTORE UNIT TO PROPER CONFIGURATION |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 10 | MANUALL OPERATE ALL ASSOCIATED VALVES FOR PROPER AND SMOOTH OPERATION |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 11 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 11 | etc), when applicable, of work accomplished and any pertinent information |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 11 | regarding the facility. |
| ANNUAL BACK FLOW PREVENTER | PM040019 | 3000001 | 12 | Notify Work Control Center of any follow up work required. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | OBSERVE ALL ELECTRICAL HAZARD SAFETY MANDATES. ELECTRIC INSULATED BOOTS, |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | THIS MAINTENANCE INSTRUCTION CONTAINS MANY EXTERNAL DOCUMENT REFERENCES. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | GLOVES, AND EYE PROTECTION ARE REQUIRED PPE WHEN PERFORMING THIS TASK. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | THESE DOCUMENTS MUST BE ON HAND DURING WORK. THEY ARE THE APPLICABLE |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | SECTIONS OF: EWR 127-1, AFSPCMAN 91-710, ANSI/ASME B30 SERIES, CMAA 70 AND |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | TOOLS MUST BE RATED FOR VOLTAGE OF ELECTRICAL WORK. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | 74, AFOSH 91-46, NFPA, CFR (FED. OSHA), CAL OSHA, AND THE COMPREHENSIVE |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | MAINTENANCE PLAN BY GLOBAL CRANE INST. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | THE REQUIRED REFERENCES ARE THE APPLICABLE SECTIONS OF: EWR 127-1, |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | WORK HEIGHT HAZARD. FALL PROTECTION MUST BE WORN AND MUST BE ATTACHED TO A |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | AFSPCMAN 91-710, ANSI/ASME B30 SERIES, CMAA 70 AND 74, AFOSH 91-46, NFPA, |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | STRUCTURAL MEMBER CAPABLE OF A 5000# VERTICAL LOAD IF WORKING 6' OR MORE |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | ABOVE GROUND LEVEL OUTSIDE MEZZANINE OR IN AN UN-RAILGUARDED SPACE. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | CFR (FED. OSHA), CAL OSHA, AND THE COMPREHENSIVE MAINTENANCE PLAN FOR |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | CRANES AND HOISTS CREATED BY GLOBAL CRANE INSTITUTE |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | HEAVY MATERIAL HANDLING HAZARD. HARDHATS MUST BE WORN AT ALL TIMES. CLEAR |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | PERSONNEL WITHIN 25' OF CRANE ENVELOPE AND POST VISUAL WARNING SIGNS AROUND |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | THE WORK AREA PRIOR TO WORK. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | SITE MAINTENANCE LEAD SHALL PERFORM PRE-OP COMMUNICATION MEETING COVERING |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | HAZARDS, EMERGENCY PROCEDURES, MANDATORY SAFETY EQUIPMENT AND ACTIONS, |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 0 | 0 | PROPER COMMUNICATION, AND TEST/MAINTENANCE PROCEDURAL TASKS TO BE PERFORMED |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 1 | NOTIFY FACILITY MANAGER AND ALL RELEVANT AUTHORITIES PRIOR TO COMMENCING |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 1 | WORK. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 2 | PERFORM MAINTENANCE INSTRUCTION PM600032 IN CONJUNCTION WITH THIS WORK |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 2 | ORDER. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 3 | INFORM OR ASK FACILITY MANAGER TO INFORM FACILITY PERSONNEL OF IMPENDING |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 3 | WORK, CLEAR PERSONNEL WITHIN 25' OF CRANE ENVELOPE, AND POST WARNING SIGNS |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 3 | AROUND THE WORK AREA PRIOR TO COMMENCEMENT. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 4 | ENSURE ALL TEST WEIGHTS ARE PROPERLY MARKED WITH TOTAL WT. AND CERTIFYING |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 4 | AGENCY. INSPECT ENTIRE SURFACE FOR STRESS CRACKS. REBAR IS NOT TO BE USED |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 4 | AS A LIFTING POINT. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 5 | PERFORM ANNUAL CRITICAL CRANE 100% LOAD TEST IAW EWR 127-1 3.6.2.2.14, |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 5 | AFSPCMAN 91-710 V3 6.2.2.1 AND 6.2.5.2, ASME B30 SERIES, OSHA/AFOSH, AND |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 5 | ALL APPLICABLE STANDARDS AND REGULATIONS. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 6 | LIFT TEST LOAD APPROXIMATELY 2 FT. OFF GROUND LEVEL FOR 3 MINUTES OR MORE. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 6 | VERIFY HOIST DRUM ROTATION AND TEST WT. DRIFT IS WITHIN ACCEPTABLE LIMITS |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 6 | AS PER MFG RECOMMENDATIONS. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 7 | TEST HOIST OVERLOAD DETECTION SYSTEM. VERIFY ACTIVATION AT 110% OF RATED |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 7 | LOAD. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 8 | REMOVE ELECTRICAL POWER AND TEST HOLDING AND EMERGENCY BRAKE DRUMS. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 8 | MANUALLY RELEASE EACH BRAKE IN A MANNER THAT WILL TEST EACH INDIVIDUAL |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 8 | BRAKE FOR PROPER FUNCTION. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 9 | RESTORE POWER AND RAISE LOAD TO MAXIMUM HEIGHT AND LOWER IN 3 INCREMENTS, |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 9 | STOPPING EACH TIME TO VERIFY THERE IS NO UNCOMMANDED DRUM ROTATION OR TEST |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 9 | WEIGHT LOWERING. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 10 | TRANSPORT TEST WEIGHT, AS PRACTICAL, THE FULL LENGTH OF THE BRIDGE AND |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 10 | RUNWAY ONCE WITH TEST LOAD AT EACH EXTREME END OF THE BRIDGE. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 11 | MOVE TEST WEIGHT THROUGHOUT ENTIRE ENVELOPE STOPPING AT RANDOM TO TEST |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 11 | SMOOTH OPERATION. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 12 | TEST CRANE CONTROLS TO VERIFY REVERSING OR PLUGGING CAN CONTROL OR STOP |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 12 | THE HOIST, TROLLEY, AND BRIDGE MOTIONS. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 13 | TEST BRIDGE AND TROLLEY BRAKES FOR PROPER OPERATION IAW CMAA 70 AND 74 AND |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 13 | ANSI B30 SERIES. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 14 | TEST THE EMERGENCY LOAD LOWERING SYSTEM (IF EQU'D) NOT LOWERING THE TEST |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 14 | LOAD MORE THAN A FEW FEET. INSPECT BRAKES FOLLOWING THE EMERGENCY |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 14 | LOWERING SYS. TEST. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 15 | TEST THE BRIDGE, TROLLEY, AND HOIST AT EACH AVAILABLE SPECIFIED SPEED. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 16 | TEST THE LOAD SLIPPAGE DETECTION SYSTEM, AND VERIFY LOAD DROP IS WITHIN |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 16 | ACCEPTABLE LIMITS. FOR NON-FAIL SAFE MICRODRIVE SYSTEMS, SIMULATE |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 16 | ELECTRICAL AND MECHANICAL CLUTCH FAILURE. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 17 | FOLLOWING THE LOAD TEST, PERFORM NDE ON ALL SFP'S IAW RANGE SAFETY, ANSI |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 17 | METHODOLOGY, THE FOLLOWING HOOK INSPECTION STEPS OF THIS INSTRUCTION, AND |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 17 | THE NDE PLAN GIVEN BY THE MFG. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 18 | HOOK NDE SURFACE INSPECTION. INSPECT HOOK FOR CRACKS, NICKS, GOUGES, WEAR, |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 18 | DEFORMATION, AND MECHANICS OF LATCH. LUBRICATE AS REQUIRED. REJECT OR |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 18 | REPAIR AS NECESSARY. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 19 | INSPECT HOOK AND LOAD ATTACHMENTS AND SECURING MEANS. REJECT OR REPAIR AS |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 19 | NECESSARY. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 20 | MEASURE HOOKS FOR BENDING/TWISTING, THROAT OPENING, AND WEAR. HOOKS |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 20 | SHOWING TWISTING MORE THAN 10 DEG, THROAT OPENING EXCEEDING 15%, OR WEAR |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 20 | EXCEEDING 10% IS TO BE REJECTED IAW ASME B30.10-1.2.1.3 |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 21 | INSPECT SLINGS IAW ITS CHAPTER IN ASME B30.9. INSPECTION TO INCLUDE, BUT |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 21 | NOT LIMITED TO, TEARS, BROKEN/DEFORMED STRANDS, CORROSION, KINKING, |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 21 | SUB-NOMINAL DIAMETER, AND CHAIN WEAR IAW ASME B30.9 TABLE 3. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 22 | CHECK THAT SLINGS ARE MARKED IAW ITS CHAPTER IN ASME B30.9 TO INCLUDE, BUT |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 22 | NOT LIMITED TO, MFG, GRADE AND SIZE, AND RATED LOAD. UNMARKED OR MISMARKED |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 22 | SLINGS SHALL BE REJECTED. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 23 | COORDINATE AND PROCEED TO PROOF TEST ALL AIR FORCE OWNED SLINGS USED TO |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 23 | HANDLE CRITICAL HARDWARE AT 200% OF THEIR RATED LOAD. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 24 | RECORD AND FILE TEST RESULTS OR FILE SUBCONTRACTOR TEST RESULTS OF ALL |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 24 | SLING AND/OR HOOK INSPECTION AND TESTING RESULTS WITH THE ASSOCIATED CRANE |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 24 | OR LOSC TOOL FILE. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 25 | CRANE/HOIST NO-LOAD FUNCTION TEST. FOLLOWING THE LOAD TEST, PERFORM |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 25 | COMPLETE FUNCTIONAL TEST OF ALL CONTROL SYSTEMS, SAFETY DEVICES, AND |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 25 | WARNING INDICATORS. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 26 | TEST ALL WARNING DEVICES: AUDIBLE BELLS/HORNS, VISUAL WARNING LIGHTS, |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 26 | TRAVEL WARNING INDICATORS, ETC. FOR PROPER OPERATION. SYSTEMS SHOULD BE |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 26 | OPERATIONAL AT ALL TIMES DURING CRANE USE. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 27 | INSPECT CAB FOR PROPERLY LABELED CONTROLS, OPERABLE LIGHTING, AND PROPER |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 27 | OPERATION OF DOOR AND LATCHING DEVICE. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 28 | TEST RADIO COMMUNICATIONS SYSTEM (IF EQUPD) FOR PROPER OPERATION. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 29 | TEST EVERY FUNCTION OF THE CRANE TO INCLUDE, BUT NOT LIMITED TO, TRAVEL |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 29 | LIMITS, LIFTING/LOWERING, BRAKING, FAIL-SAFE SYSTEMS, AND EMERGENCY STOPS |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 29 | AT ALL SPEEDS. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 30 | RECORD RESULTS OF LOAD TEST, MAINTENANCE INSPECTIONS, FUNCTIONAL |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 30 | INSPECTIONS, AND NON-DESTRUCTIVE EXAMINATIONS AND FILE WITH THE ASSOCIATED |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 30 | CRANE'S RECORDS. UPDATE ALL EQUIPMENT ID TAGS. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 31 | NOTIFY FACILITY MANAGER AND ALL RELEVANT AUTHORITIES OF WORK ACCOMPLISHED |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 31 | AND ANY PERTINENT INFORMATION REGARDING THE UNIT. |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 32 | NOTIFY WORK CONTROL OF WORK ACCOMPLISHED, AND OPEN REPAIR WORK ORDERS AS |
| ANNUAL CRANE/HOIST MAINTENANCE AND CERTIFICATION | PM700001 | 3000001 | 32 | NECESSARY. |
| ANNUAL FIRE EXTINGUISHER CERTIFICATION | PM700006 | 3000001 | 1 | IT IS THE RESPONSIBILITY OF FACILITY MANAGERS AND/OR TECHNICIANS TO |
| ANNUAL FIRE EXTINGUISHER CERTIFICATION | PM700006 | 3000001 | 1 | PERFORM MONTHLY CHECK FOR EACH UNITS ASSIGNED |
| ANNUAL FIRE EXTINGUISHER CERTIFICATION | PM700006 | 3000001 | 2 | SUBMIT/DELIVER FIRE EXTINGUISHER/S TO QS&E DEPARTMENT FOR THE ANNUAL |
| ANNUAL FIRE EXTINGUISHER CERTIFICATION | PM700006 | 3000001 | 2 | CERTIFICATION |
| ANNUAL VEHICLE REGISTRATION RENEWAL | PM700013 | 3000001 | 1 | It is the responsibility of the user to keep a valid copy of vehicle |
| ANNUAL VEHICLE REGISTRATION RENEWAL | PM700013 | 3000001 | 1 | registration renewal and insurance at all times. |
| ANNUAL VEHICLE REGISTRATION RENEWAL | PM700013 | 3000001 | 2 | Check and ensure that the vehicle is in excellent operating condition |
| ANNUAL VEHICLE REGISTRATION RENEWAL | PM700013 | 3000001 | 2 | before closing the work order. |
| AUTOMATIC DAMPER | PM040094 | 3000001 | 1 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AUTOMATIC DAMPER | PM040094 | 3000001 | 1 | etc.), when applicable, of work to be accomplished. |
| AUTOMATIC DAMPER | PM040094 | 3000001 | 2 | INSPECT MECHANICAL CONDITION OF UNIT |
| AUTOMATIC DAMPER | PM040094 | 3000001 | 3 | INSPECT PNEUMATIC SYSTEM FOR LEAKS,ETC (IF EQUIPPED) |
| AUTOMATIC DAMPER | PM040094 | 3000001 | 4 | INSPECT OPERATION OF ACTUATOR |
| AUTOMATIC DAMPER | PM040094 | 3000001 | 5 | ADJUST / STRAIGHTEN VANES, LINKS, & LOUVERS AS REQD |
| AUTOMATIC DAMPER | PM040094 | 3000001 | 6 | CHECK FOR ERRATIC OR STICKY ACTION |
| AUTOMATIC DAMPER | PM040094 | 3000001 | 7 | REPAIR OR REPLACE DEFECTIVE PARTS AS NECESSARY |
| AUTOMATIC DAMPER | PM040094 | 3000001 | 8 | LUBRICATE MOVING PARTS IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS |
| AUTOMATIC DAMPER | PM040094 | 3000001 | 9 | ADJUST OR RECALIBRATE CONTROL UNIT TO CORRECT POSITION AS NECESSARY |
| AUTOMATIC DAMPER | PM040094 | 3000001 | 10 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AUTOMATIC DAMPER | PM040094 | 3000001 | 10 | etc), when applicable, of work accomplished and any pertinent information |
| AUTOMATIC DAMPER | PM040094 | 3000001 | 10 | regarding the facility. |
| AUTOMATIC DAMPER | PM040094 | 3000001 | 11 | Notify Work Control Center of any follow up required. |
| AUTOMATIC DOOR | PM040088 | 2000001 | 1 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AUTOMATIC DOOR | PM040088 | 2000001 | 1 | etc.), when applicable, of work to be accomplished. |
| AUTOMATIC DOOR | PM040088 | 2000001 | 2 | VERIFY TIMING & SPEED OF DOOR OPENING AND CLOSING |
| AUTOMATIC DOOR | PM040088 | 2000001 | 3 | ADJUST AS REQUIRED |
| AUTOMATIC DOOR | PM040088 | 2000001 | 4 | CHECK SAFETY DEVICES AND MATS OR SENSORS. |
| AUTOMATIC DOOR | PM040088 | 2000001 | 5 | CHECK LATCHES, HINGES, FASTENERS, ETC. |
| AUTOMATIC DOOR | PM040088 | 2000001 | 6 | CHECK OPERATION OF CYLINDERS, RODS, LINKAGES, CHAINS, ETC. |
| AUTOMATIC DOOR | PM040088 | 2000001 | 7 | POWER OFF UNIT, LOCKOUT AND TAGOUT DISCONNECT |
| AUTOMATIC DOOR | PM040088 | 2000001 | 8 | ADJUST, REPAIR OR REPLACE PARTS AS NECESSARY |
| AUTOMATIC DOOR | PM040088 | 2000001 | 9 | CHECK LEVEL OF HYDRAULIC OIL & TOP OFF OR CHANGE (IF EQP'D) |
| AUTOMATIC DOOR | PM040088 | 2000001 | 10 | IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS |
| AUTOMATIC DOOR | PM040088 | 2000001 | 11 | CHECK ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC. |
| AUTOMATIC DOOR | PM040088 | 2000001 | 12 | TIGHTEN TERMINALS & CONNECTIONS AS REQ'D |
| AUTOMATIC DOOR | PM040088 | 2000001 | 13 | REMOVE LOCKOUT AND RESTORE POWER TO UNIT |
| AUTOMATIC DOOR | PM040088 | 2000001 | 14 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AUTOMATIC DOOR | PM040088 | 2000001 | 14 | etc), when applicable, of work accomplished and any pertinent information |
| AUTOMATIC DOOR | PM040088 | 2000001 | 14 | regarding the facility. |
| AUTOMATIC DOOR | PM040088 | 2000001 | 15 | Notify Work Control Center of any follow up required. |
| AUTOMATIC GATE | PM040165 | 2000001 | 1 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| AUTOMATIC GATE | PM040165 | 2000001 | 1 | etc.), when applicable, of work to be accomplished. |
| AUTOMATIC GATE | PM040165 | 2000001 | 2 | VERIFY PROPER OPERATION OF THE UNIT |
| AUTOMATIC GATE | PM040165 | 2000001 | 3 | POWER OFF UNIT, LOCKOUT AND TAGOUT DISCONNECT |
| AUTOMATIC GATE | PM040165 | 2000001 | 4 | VERIFY CONDITION OF EXTERIOR COVERS AND HOUSINGS |
| AUTOMATIC GATE | PM040165 | 2000001 | 5 | CLEAN AND LUBRICATE FRICTION BEARING SURFACES |
| AUTOMATIC GATE | PM040165 | 2000001 | 6 | CHECK & ADJUST BELT OR CHAIN TENSION/ALIGNMENT IF APPLICABLE |
| AUTOMATIC GATE | PM040165 | 2000001 | 7 | CHECK ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC. TIGHTEN TERMINALS & |
| AUTOMATIC GATE | PM040165 | 2000001 | 7 | CONNECTIONS AS REQ'D |
| AUTOMATIC GATE | PM040165 | 2000001 | 8 | CHECK LIMIT SWITCH FOR PROPER OPERATION |
| AUTOMATIC GATE | PM040165 | 2000001 | 9 | INSPECT ACTUATOR ARM AND SHAFT FASTENERS |
| AUTOMATIC GATE | PM040165 | 2000001 | 10 | REPAIR OR REPLACE DEFECTIVE PARTS AS NECESSARY |
| AUTOMATIC GATE | PM040165 | 2000001 | 11 | REMOVE LOCKOUT AND RESTORE POWER TO UNIT |
| AUTOMATIC GATE | PM040165 | 2000001 | 12 | Notify Work Control Center of any follow up required. |
| BASIN AERATOR | PM040007 | 2000001 | 1 | Notify Facility Manager and all relevant authorities, (E.G. Fire Dept.), |
| BASIN AERATOR | PM040007 | 2000001 | 1 | when applicable, of work to be accomplished. |
| BASIN AERATOR | PM040007 | 2000001 | 2 | POWER OFF UNIT, LOCKOUT AND TAGOUT DISCONNECT |
| BASIN AERATOR | PM040007 | 2000001 | 3 | CHECK GEAR DRIVE OIL LEVEL AND TOP OFF OR CHANGE |
| BASIN AERATOR | PM040007 | 2000001 | 4 | IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS |
| BASIN AERATOR | PM040007 | 2000001 | 5 | CHECK FOR WATER IN OIL TO VERIFY SHAFT SEAL CONDITION. |
| BASIN AERATOR | PM040007 | 2000001 | 6 | CLEAN DIRT & DEBRIS FROM MOTOR WINDINGS |
| BASIN AERATOR | PM040007 | 2000001 | 7 | CHECK THE MECHANICAL CONDITION OF THE UNIT |
| BASIN AERATOR | PM040007 | 2000001 | 8 | TIGHTEN ALL FASTENERS (SCREWS, NUTS, BOLTS,ETC) AS REQD |
| BASIN AERATOR | PM040007 | 2000001 | 9 | CHECK ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC. |
| BASIN AERATOR | PM040007 | 2000001 | 10 | TIGHTEN, REPAIR OR REPLACE AS NECESSARY |
| BASIN AERATOR | PM040007 | 2000001 | 11 | LUBRICATE MOVING PARTS |
| BASIN AERATOR | PM040007 | 2000001 | 12 | IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS |
| BASIN AERATOR | PM040007 | 2000001 | 13 | RESTORE POWER TO THE UNIT AND VERIFY PROPER OPERATION |
| BASIN AERATOR | PM040007 | 3000001 | 14 | Notify Facility Manager and all relevant authorities, (E.G. Fire Dept.), |
| BASIN AERATOR | PM040007 | 3000001 | 14 | when applicable, of work accomplished and any pertinent information |
| BASIN AERATOR | PM040007 | 3000001 | 14 | regarding facility. |
| BASIN AERATOR | PM040007 | 3000001 | 15 | Notify Work Control Center of any follow up required. |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 1 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 1 | etc.), when applicable, of work to be accomplished. |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 2 | POWER OFF UNIT, LOCKOUT TAGOUT DISCONNECT |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 3 | INSPECT CONDITION OF THE UNIT |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 4 | CHECK ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC. |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 5 | TIGHTEN TERMINALS & RESEAT CONNECTORS AS REQD |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 6 | CLEAN EXTERIOR OF UNIT AND SURROUNDING AREA |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 7 | BLOW CLEAN INT. OF ELECTRONICS TO REMOVE DUST/LINT |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 8 | CHECK ELECTROLYTE LEVEL OF BATTERIES & TOP OFF IF REQD |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 9 | MEASURE AND RECORD BATTERY'S Z, V, I USING BATT IMPED. TESTER |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 10 | REPAIR/REPLACE PARTS AS NEEDED |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 11 | RESTORE POWER TO THE UNIT AND VERIFY PROPER OPERATION |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 12 | MEASURE & RECORD OPERATING INPUT/OUTPUT VOLT/CURR OF CHARGER |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 13 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 13 | etc), when applicable, of work accomplished and any pertinent information |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 13 | regarding the facility. |
| BATTERY BANK/CHARGER CRIT A | PM040031 | 2000001 | 14 | Notify Work Control Center of any follow up required. |
| BATTERY CHARGER (OBSOLETE) | PM040032 | 3000001 | 1 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| BATTERY CHARGER (OBSOLETE) | PM040032 | 3000001 | 1 | etc.), when applicable, of work to be accomplished. |
| BATTERY CHARGER (OBSOLETE) | PM040032 | 3000001 | 2 | POWER OFF UNIT, LOCKOUT AND TAGOUT DISCONNECT |
| BATTERY CHARGER (OBSOLETE) | PM040032 | 3000001 | 3 | CLEAN EXTERIOR OF UNIT |
| BATTERY CHARGER (OBSOLETE) | PM040032 | 3000001 | 4 | BLOW CLEAN INT. OF ELECTRONICS TO REMOVE DUST AND LINT |
| BATTERY CHARGER (OBSOLETE) | PM040032 | 3000001 | 5 | CHECK ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC. |
| BATTERY CHARGER (OBSOLETE) | PM040032 | 3000001 | 6 | TIGHTEN TERMINALS & RESEAT CONNECTORS AS REQUIRED |
| BATTERY CHARGER (OBSOLETE) | PM040032 | 3000001 | 7 | INSPECT MECHANICAL CONDITION OF UNIT |
| BATTERY CHARGER (OBSOLETE) | PM040032 | 3000001 | 8 | REPAIR OR REPLACE DEFECTIVE PARTS AS NECESSARY |
| BATTERY CHARGER (OBSOLETE) | PM040032 | 3000001 | 9 | RESTORE POWER TO THE UNIT AND VERIFY PROPER OPERATION |
| BATTERY CHARGER (OBSOLETE) | PM040032 | 3000001 | 10 | MEASURE & RECORD OPERATING SUPPLY VOLTAGE & CURRENT |
| BATTERY CHARGER (OBSOLETE) | PM040032 | 3000001 | 11 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| BATTERY CHARGER (OBSOLETE) | PM040032 | 3000001 | 11 | etc), when applicable, of work accomplished and any pertinent information |
| BATTERY CHARGER (OBSOLETE) | PM040032 | 3000001 | 11 | regarding the facility. |
| BATTERY CHARGER (OBSOLETE) | PM040032 | 3000001 | 12 | Notify Work Control Center of any follow up required |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 0 | 0 | WORK TASK INVOLVES HANDLING OF BATTERIES AND TERMINALS. TECHNICIAN MUST |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 0 | 0 | WEAR GLOVES AND SAFETY GLASSES/GOGGLES. |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 1 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 1 | etc.), when applicable, of work to be accomplished. |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 2 | UPLOAD ROUTE INFORMATION FROM SERVER TO BATTERY IMPEDANCE TEST EQUIPMENT. |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 3 | ENSURE EQUIPMENT TO BE ANALYZED IS PROPERLY BARCODED. |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 4 | NOTIFY FACILITY MANAGER(S) OF TASK TO BE PERFORMED AND WHICH EQUIPMENT IS |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 4 | AFFECTED. |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 5 | TAKE NOTE OF GENERAL CONDITION OF EQUIPMENT AND SURROUNDING AREA. |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 6 | TAKE BATTERY IMPEDANCE READINGS AND SAVE INFORMATION INTO TESTING UNIT. |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 7 | DOWNLOAD READINGS ONTO SERVER. |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 8 | NOTIFY ENGINEERING DEPARTMENT OF ANY SUSPECTED ANOMALIES. |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 9 | OPEN FOLLOW UP WORK ORDERS AS DEEMED NECESSARY. |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 10 | ASSIST ENGINEERING DEPARTMENT WITH ANY DATA ANALYSIS. |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 11 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 11 | etc), when applicable, of work accomplished and any pertinent information |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 11 | regarding facility. |
| BATTERY IMPEDANCE TEST ROUTE A | PM600017 | 2000003 | 12 | Notify Work Control Center of any follow up required.� |
| BATTERY IMPEDANCE TEST ROUTE B | PM600025 | 0 | 0 | WORK TASK INVOLVES HANDLING OF BATTERIES AND TERMINALS. TECHNICIAN MUST |
| BATTERY IMPEDANCE TEST ROUTE B | PM600025 | 0 | 0 | WEAR GLOVES AND SAFETY GLASSES/GOGGLES. |
| BATTERY IMPEDANCE TEST ROUTE B | PM600025 | 2000006 | 1 | UPLOAD ROUTE INFORMATION FROM SERVER TO BATTERY IMPEDANCE TEST EQUIPMENT. |
| BATTERY IMPEDANCE TEST ROUTE B | PM600025 | 2000006 | 2 | ENSURE EQUIPMENT TO BE ANALYZED IS PROPERLY BARCODED. |
| BATTERY IMPEDANCE TEST ROUTE B | PM600025 | 2000006 | 3 | NOTIFY FACILITY MANAGER(S) OF TASK TO BE PERFORMED AND WHICH EQUIPMENT IS |
| BATTERY IMPEDANCE TEST ROUTE B | PM600025 | 2000006 | 3 | AFFECTED. |
| BATTERY IMPEDANCE TEST ROUTE B | PM600025 | 2000006 | 4 | TAKE NOTE OF GENERAL CONDITION OF EQUIPMENT AND SURROUNDING AREA. |
| BATTERY IMPEDANCE TEST ROUTE B | PM600025 | 2000006 | 5 | TAKE BATTERY IMPEDANCE READINGS AND SAVE INFORMATION INTO TESTING UNIT. |
| BATTERY IMPEDANCE TEST ROUTE B | PM600025 | 2000006 | 6 | DOWNLOAD READINGS ONTO SERVER. |
| BATTERY IMPEDANCE TEST ROUTE B | PM600025 | 2000006 | 7 | NOTIFY ENGINEERING DEPARTMENT OF ANY SUSPECTED ANOMALIES. |
| BATTERY IMPEDANCE TEST ROUTE B | PM600025 | 2000006 | 8 | OPEN FOLLOW UP WORK ORDERS AS DEEMED NECESSARY. |
| BATTERY IMPEDANCE TEST ROUTE B | PM600025 | 2000006 | 9 | ASSIST ENGINEERING DEPARTMENT WITH ANY DATA ANALYSIS. |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 1000001 | 1 | Notify Facility Manager and all relevant authorities, (e.g. Fire Dept., |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 1000001 | 1 | etc.), when applicable, of work to be accomplished. |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 1000001 | 2 | PERFORM WEEKLY OPERATION: After completing daily ops; visually check |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 1000001 | 2 | valves, linkages, limit/safety/pressure switches, controls, conduct |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 1000001 | 2 | housekeeping |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 1000001 | 3 | AFTER PERFORMING DAILY AND WEEKLY OPERATION, PERFORM THE FOLLOWING MONTHLY |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 1000001 | 3 | STEPS; |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 2000001 | 4 | CHECK OPERATION OF BURNER CONTROL SYSTEM |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 2000001 | 5 | CHECK SAFETY VALVE AND LOW WATER CUTOFF SYSTEMS FOR ABNORMAL SIGNS |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 2000001 | 6 | CHECK ELECTRICAL WIRING, CONNECTIONS, TERMINALS, ETC. |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 2000001 | 7 | CHECK ALL ASSOCIATED VALVES TO ENSURE PROPER OPERATION |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 2000001 | 8 | PERFORM NECESSARY ADJUSTMENTS TO KEEP UNIT IN OPERATING CONDITION |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 2000001 | 9 | INSPECT FOR RUST, CORROSION, CRACKS, PINHOLES, ETC. |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 3000001 | 10 | FOR ANNUAL MAINTENANCE, LOCKOUT/TAGOUT THE UNIT |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 2000001 | 11 | TURN OFF THE GAS SUPPLY & ALLOW UNIT TO COOL |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 2000001 | 12 | CLEAN INTERIOR AND EXTERIOR OF THE UNIT |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 2000001 | 13 | INSPECT INTERIOR FOR DEFECTIVE TUBES, GASKETS, FIREBRICK, ETC. |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 2000001 | 14 | INSPECT THE UNIT FOR WATER LEAKS. CLEAN WATER SIDE SURFACES, REMOVE ALL |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 2000001 | 14 | HEAD PLATES AND INSPECT TUBES, INSPECT WATER COLUMNS |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 2000001 | 15 | CHECK CONDITION OF GAUGE GLASS. |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 2000001 | 16 | INSPECT RELIEF VALVE, TRAPS, STEAM LINES, ETC |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 2000001 | 17 | CLEAN ALL RUST, CORROSION, ETC FROM UNIT |
| BOILER OPERATION AND MAINTENANCE | PM040023 | 3000001 | 18 | CLEAN FIREBOX, BURNER, FLUE, ETC |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .