TO 31R4-2GRN29-3 TECHNICAL MANUAL CIRCUIT DIAGRAMS INSTRUMENT LANDING SYSTEM
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TO 31R4-2GRN29-3
1 JUNE 2006 CHANGE 1 12 APRIL 2011
TECHNICAL MANUAL
CIRCUIT DIAGRAMS
INSTRUMENT LANDING SYSTEM
AN/GRN-29(V)
ELECTRICAL EQUIPMENT SHELTER S-588/G
PART NO. 083716-0001
CONTROL-INDICATOR C-10307/G
PART NO. 098299-0100
AND
INTERLOCK CONTROL C-10306/G
PART NO. 098342-0100
WILCOX ELECTRIC, INC.
THIS REVISION SUPERSEDES TO 31R4-2GRN29-3 DATED 15 JANUARY 1988
AND ALL CHANGES THROUGH CHANGE 1 DATED 1 DECEMBER 2005.
DISTRIBUTION STATEMENT C - Distribution authorized to U S. Government agencies and their contractors for administrative or operational use, 12 April 2011. Refer other requests for this document to OC-ALC/GKAAB, Tinker AFB, Oklahoma 73145-9155.
WARNING - This document contains technical data whose export is restricted by the Arms Export Control Act (Title 22, U.S.C. 2751 et seq.) or Executive Order 12470. Violations of these export laws are subject to severe criminal penalties. Disseminate in accor-dance with provisions of DoD Directive 5230.25.
HANDLING AND DESTRUCTION NOTICE - Handle in compliance with distribution statement and destroy by any method that will prevent disclosure of the contents or reconstruction of the document.
PUBLISHED UNDER THE AUTHORITY OF THE SECRETARY OF THE AIR FORCE
*Zero in this column indicates an original page
A Change 1 USAF
NOTE: The portion of the text affected by the change is indicated by a vertical line in the outer margins of the page. Changes to illustrations are indicated by miniature pointing hands. Changes to wiring diagrams are indicated by shaded or screened areas.
TOTAL NUMBER OF PAGES IN THIS MANUAL IS 32, CONSISTING OF THE FOLLOWING:
Title A i - ii 1-1 - 1-2 2-1 2-2 Blank
FP-1
FP-2 Blank
FP-3
FP-4 Blank
FP-5
FP-6 Blank
FP-7
FP-8 Blank
FP-9
FP-10 Blank
FP-11
FP-12 Blank
FP-13
FP-14 Blank
FP-15
FP-16 Blank
FP-17
FP-18 Blank
FP-19
FP-20 Blank
FP-21
FP-22 Blank
FP-23
FP-24 Blank
Dates of issue for original and changed pages are:
Original . . . . . . . . . . . . . . . . 0 . . . . . . . . . .1 June 2006 Change. . . . . . . . . . . . . . . . 1 . . . . . . . . . .12 April 2011
Page No.
*Change No.
Page No
*Change No.
Page No.
*Change No.
INSERT LATEST CHANGED PAGES. DESTROY SUPERSEDED PAGES.LIST OF EFFECTIVE PAGES
i
TABLE OF CONTENTS
TO 31R4-2GRN29-3
Chapter/Para Page
LIST OF ILLUSTRATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii
1 INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.1 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.2 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.3 INTEGRATED CIRCUIT PIN LOCATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.4 SPECIAL GRAPHIC SYSMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.5 TEST POINT IDENTIFICATION SYMBOLS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
2 CIRCUIT DIAGRAMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 ii
Number Title Page
1-1 Integrated Circuit Pin Locations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 FO-1. Shelter - Wiring Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FP-1 FO-2. RC/DU Chassis, Schematic Diagram (3 Sheets). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FP-3 FO-3. RC/DU Chassis, Schematic Diagram. (2 Sheets) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FP-9 FO-4. Decoder/Control Assembly, Schematic Diagram. (2 Sheets) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FP-13 FO-5. Intercom Assembly, Schematic Diagram. (2 Sheets) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FP-17 FO-6. Battery Backup Assembly, Schematic Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FP-21 FO-7. ICU, Schematic Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FP-23
LIST OF ILLUSTRATIONS
CHAPTER 1
INTRODUCTION
1.1 GENERAL.
Figure FO-1 is wiring diagram for shelter. Use this diagram when replacing electrical components and troubleshooting electrical circuits.
1.2 TROUBLESHOOTING.
Each electrical circuit is fed by a separate circuit breaker. This aids in isolating a problem such as a circuit breaker that trips constantly or an open circuit. Use FO-1 to troubleshoot equipment as follows:
a. Wiring for Main Power. Obstruction Light, Antenna Heater, and Circuit Breaker Panelboard.
b. Interior Connections of Circuit Breaker Panel - board.
c. Wiring for Fans and DC Circuits.
d. Wiring for Air Conditioner and Supplemental Heater
e. Wiring for Convenience Outlets 11J5 through 11J11.
f. Wiring for Convenience Outlets 11J12 through 11J16 and Incandescent Lights.
1.3 INTEGRATED CIRCUIT PIN LOCATION.
Figure 1-1 shows intergrated circuit pin locations that may be used.
1.4 SPECIAL GRAPHIC SYSMBOLS.
There are no special graphic symbols used on circuit diagrams.
1.5 TEST POINT IDENTIFICATION SYMBOLS.
a. Major test points are identified by star encircled Arabic 1 numerals, , and are used in checking overall functions of assemblies or groups of components.
b. Secondary test points are identified by encircled capital A letters, , and are used in isolating faults to stages within assemblies or subassemblies.
c. Minor test points are identified by a capital letter and A1Arabic numeral, both within a single circle, , and are used to isolate faults to components within a gate.
A
A1 1-1
Figure 1-1. Integrated Circuit Pin Locations.
16-PIN DUAL-IN-LINE
TOP VIEW
14-PIN DUAL-IN-LINE
TOP VIEW
T.O. PACKAGE
BOTTOM VIEW
18,10 OR 12
T.O. PACKAGE
BOTTOM VIEW
18,10 OR 12
29-3 F2-1 1-2
CHAPTER 2
CIRCUIT DIAGRAMS
2-1/(2-2 Blank)
FP-1/(FP-2 Blank)
FO-1. Shelter - Wiring Diagram.
CB5
N
15A
A B
CB10
CB11
15A
15A
15A
CB4
15A
CB3
60A
CB1
(GFCI)
14 AWG
PANEL BOARD
OUTSIDE OUTLET
J5
14 AWG DAMPER
B2
14 AWG
2 PL
14 AWG
14 AWG
14 AWG
14 AWG
14 AWG
14 AWG
A2
14 AWG
14 AWG
Y
B
R
14 AWGFAN
B3
14 AWG
2 PL
14 AWGDAMPER
B1
14 AWG
2 PL
14 AWG
14 AWG
CB14 30A DC MAIN
CB13 15A GFCI OBSTN LIGHT
CB12 15A BATTERY FAN
CB11 15A THERMO/FAN CTRL
CB10 15A GFCI OUTSIDE OUTLET (J5)
CB9 20A
CB8 20A
CB7 20A
CB6 15A LIGHTS
CB5 15A BATTERY CHARGER
CB4 15A BATTERY CHARGER
CB3 15A
ANT HEATER (GS)
CB2 30A A/C
CB1 60A 2 MAIN
DESIG. RATING POLES
DESCRIPTION
CIRCUIT BREAKERREF
SPARE (LOC)
BARE SOLID COPPER WIRE
(MOUNTED OVER WORK BENCH)
14 AWG
OUTSIDE
GROUND
STUD
B
N 5
G
B
G
A
TB2
MAIN
A 1
B
N
TB1
TB3
6 AWG
14 AWG
GFCI15A
CB13
4 AWG
4 AWG
EQUIPMENT CABINETS
BATTERY BOX
14 AWG
14 AWG
BATTERY
CHARGER
DC SECTION 2
14 AWG
AC
AC
14 AWG
14 AWG
14 AWG
4 AWG
4 AWG
4 AWG
OBSTN
LIGHT
CB14
30A
DC MAIN
6 AWG
CB15
20A
(GFCI)
(SPARE)
10 AWG
10 AWG
CB16
15A
(SPARE)
S2
SURGE
ARRESTER
E1
1 11
REKAERB TIUCRIC ETOMER *
CB17 20A SPARE
CB16 15A SPARE
CB15 20A GFCI SPARE
MAIN
SWITCH
14 AWG
14 AWG
14 AWG
14 AWG
BATTERY
CHARGER
CB17
20A
(SPARE)
A
B
N
G
4 AWG
14 AWG
NEUTRAL
BUS
TB4
*30A
CB2
10 AWG
10 AWG
10 AWG
J4
B
C
A
G
J
D C
B
R Y
P2J17
18 AWG
A
B
D C
A
B
P3
B
C
A
10 AWG
10 AWG
10 AWG
A1
W1 G Y1
RH
RC
18 AWG
18 AWG
18 AWG
18 AWG
B4
14 AWG
P4 J18
14 AWG
CB12
15A
14 AWG
FLOOR OUTLETS
CB7
CB8
20A
20A
12 AWG
12 AWG
J6
12 AWG
WORKBENCH OUTLETS
J7 J8 J9 J10 J11 J12 J13 J14 J15 J16
12 AWG
12 AWG
12 AWG
12 AWG
12 AWG
12 AWG
CB9
20A
12 AWG12 AWG
CB6
15A
14 AWGINCANDESCENT
LIGHTS
DS1 DS2 DS3 DS4 DS5 DS6
S3
14 AWG
14 AWG
NA B
OBSTN LIGHT
CIRCUIT
BREAKER
BATTERY
FAN
LIGHT
SWITCH
POWER ENTRY PANEL
FAN
THERMOSTAT
SREKAERB TIUCRIC
PART OF
A/C ENTRY
PANEL
AIR CONDITIONER INSTALLATION
THERMOSTAT
A/C CONTROL
AIR CONDITIONER PART OF
A/C ENTRY
PANEL
14 AWG
GS ONLY
GS ONLY
GS ONLY
14 AWG
NOTES: (UNLESS OTHERWISE SPECIFIED)
WIRE COLOR FOR DC CIRCUITS TO BE AS FOLLOWS:
GROUNDED CONDUCTOR - BLACK
UNGROUNDED CONDUCTOR - RED
4.
WIRE COLOR FOR AC CIRCUITS TO BE AS FOLLOWS:
GROUNDING CONDUCTOR - GREEN
LINE 1 UNGROUNDED CONDUCTOR - BLACK
LINE 2 UNGROUNDED CONDUCTOR - RED
GROUNDED CONDUCTOR NEUTRAL - WHITE
3.
GROUND BACK TO PANEL BOARD GROUND BUS TB4.1
PARTIAL REFERENCE DESIGNATIONS SHOWN, PREFIX WITH UNIT 11.6.
CHANGE TIME DELAY IN HEATER CONTROL BOX TO DAYTON MODEL 5X846 5
SPARE
(LOC)
ANT
HEATER
(GS)
OUTLETS (J12-J16)
OUTLETS (J6-J9)
OUTLETS (J10, J11)
LINE 2
NEUTRAL
LINE 1
GROUND
RED
BLK
RED
WHT
BLK
GRN
GRN
RED
WHT
BLK
BLK
WHT
6 AWG GRN
GRN
A
W G
RE
D
A
W G
BL
K
BARE
4 AWG
14 AWG GRN
CASE GND
BLK
14 AWG WHT
REFER TO APPLICABLE STATION MANUAL FOR CONNECTIONS.
29-3 FO2-2
FP-3/(FP-4 Blank)
FO-2. RC/DU Chassis, Schematic Diagram (Sheet 1 of 3).
FP-5/(FP-6 Blank)
FO-2. RC/DU Chassis, Schematic Diagram. (Sheet 2)
FP-7/(FP-8 Blank)
FO-2. RC/DU Chassis, Schematic Diagram. (Sheet 3)
FP-9/(FP-10 Blank)
FO-3. RC/DU Chassis, Schematic Diagram. (Sheet 1 of 2)
FP-11/(FP-12 Blank)
FO-3. RC/DU Chassis, Schematic Diagram. (Sheet 2)
FP-13/(FP-14 Blank)
FO-4. Decoder/Control Assembly, Schematic Diagram. (Sheet 1 of 2)
FO-4. Decoder/Control Assembly, Schematic Diagram. (Sheet 2) FP-15/(FP-16 Blank)
FP-17/(FP-18 Blank)
FO-5. Intercom Assembly, Schematic Diagram. (Sheet 1 of 2)
FO-5. Intercom Assembly, Schematic Diagram. (Sheet 2) FP-19/(FP-20 Blank)
FP-21/(FP-22 Blank)
FO-6. Battery Backup Assembly, Schematic Diagram.
FP-23/(FP-24 Blank)
FO-7. ICU, Schematic Diagram.
| COVER |
| TOC |
| LOI |
| CHAPTER 1 |
| CHAPTER 2 |
| FOLDOUTS |
| FO-1 |
| FO-2 |
| FO-3 |
| FO-4 |
| FO-5 |
| FO-6 |
| FO-7 |
File details come from the government source that posted it. Updated .