Appendix A - Equipment Inventory_Real Property_19 Dec 23.xlsx
XLSX spreadsheet 169 KB Posted
- Attached to
- Army Field Support Battalion (AFSBn-CHS) Facility Preventive Maintenance, Inspection & Repair Services
- Solicitation number
- FA441824Q0001
About this file
This document outlines requirements for facility preventive maintenance, inspection, and repair services for the Army Field Support Battalion (AFSBn-CHS). The solicitation was issued by the Department of the Air Force Air Mobility Command. Services are needed for facilities located at Fort Bragg, NC and include preventive and corrective maintenance for mechanical, electrical, and structural systems. The period of performance is one base year with four one-year options. Quotes are due by January 15, 2024 with award anticipated by March 2024. The contract will utilize firm-fixed-price task orders for repairs and time and materials task orders for preventive maintenance. The solicitation encourages participation from small businesses.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Equipment Inventory
| COMPLETE LIST OF RPIE EQUIPMENT IN CONTRACT LISTED PER BUILDING | ||||||||||
| Bldg | TYPE | LABELED | DESCRIPTION | MANUFACTURER | YEAR | MODEL # | SERIAL # | SIZE | LOCATION | NOTES |
| 311 | HVAC | MSACU-1 | MINI-SPLIT CONDENSER UNIT HP | MITSUBISHI ELECTRIC | 2016 | MUZ-GE09NA2 | 500493T | 3/4 TON | LOCATED ON NORTH SIDE BLDG. PAD MOUNTED | T-STAT CONTROLLED |
| 311 | HVAC | MSAHU-1 | MINI-SPLIT AIR HANDLING UNIT | MITSUBISHI ELECTRIC | 2016 | MSZ-GE09NA | 54E15005 | 3/4 TON | LOCATED ON | WASHABLE FILTER |
| 311 | HVAC | EF-1 | EXHAUST FAN CEILING MOUNTED | GREENHECK | 2016 | SP-870-QD | 15E | 6" DIA | LOCATED IN UNISEX RESTROOM CEILING | |
| 311 | PLUMBING | WHE-1 | WATER HEATER [IINSTANTANEOUS] | EeMAX | 2023 | SPEX3512 | 3014836 | 3.5 KW 120V | LOCATED IN UNISEX RESTROOM UNDER SINK | |
| 311 | PLUMBING | BFP-1 | BACKFLOW PREVENTER | WILKERSON | 2016 | LF007M3QT | 040791 | 3/4" | EXTERIOR NORTH SIDE IN GROUND BOX | |
| 311 | SECURITY | GO-1 | SLIDING GATE OPERATOR | DOORKING. INC | 2016 | SERIES 9150-084 | 3939 | 1/2 HP | INBOUND GATE EAST SIDE | CHAIN DRIVE |
| 311 | SECURITY | GO-2 | SLIDING GATE OPERATOR | DOORKING. INC | 2016 | SERIES 9150-084 | 3934 | 1/2 HP | INBOUND GATE WEST SIDE | CHAIN DRIVE |
| 311 | SECURITY | GO-3 | SLIDING GATE OPERATOR | DOORKING. INC | 2016 | SERIES 9150-084 | 3936 | 1/2 HP | OUTBOUND GATE EAST SIDE | CHAIN DRIVE |
| 311 | SECURITY | GO-4 | SLIDING GATE OPERATOR | DOORKING. INC | 2016 | SERIES 9150-084 | 3935 | 1/2 HP | OUTBOUND GATE WEST SIDE | CHAIN DRIVE |
| 311 | SECURITY | ERD-1 | APEX BOLT DOWN BARRIER [PARKING ARM] | APEX FABRICATION & DESIGN | 2019 | M530-16R | 3296-1-2 | 16' ARM 3,860 lbs. 7.8 RPM | SOUTH SIDE INBOUND GATE | PUSH BUTTON OPERATED |
| 311 | SECURITY | ERD-2 | APEX BOLT DOWN BARRIER [PARKING ARM] | APEX FABRICATION & DESIGN | 2019 | M530-16R | 3296-1-1 | 16' ARM 3,860 lbs. 7.8 RPM | SOUTH SIDE OUTBOUND GATE | PUSH BUTTON OPERATED |
| 317 | HVAC | RTPCKU-1 | ROOF TOP PACKAGE UNIT HP | TRANE | 2023 | WHCO74H3RCA29OAB3A1A000000000D0000000000 | 231613216L | 6 TON R-410A | LOW ROOF WEST SIDE ABOVE ROOM 119 CURB MOUNTED | FILTERS 16"X25"X2"=4 |
| 317 | HVAC | RTPCKU-2 | ROOF TOP PACKAGE UNIT HP | TRANE | 2020 | WSC072H3RKA04B000A1 | 2009124846 | 6 TON R-410A | LOW ROOF WEST SIDE ABOVE ROOM 113 CURB MOUNTED | FILTERS 16"X25"X2"=3 |
| 317 | HVAC | ACU-1 | AIR CONDENSER UNIT | TRANE | 2000 | TWP024C100A3 | P346DHY2F | 2 TON R-22 | NORTH SIDE OF BLDG. OUTSIDE ROOM 102A PAD MOUNTED | |
| 317 | HVAC | AHU-2 | AIR HANDLING UNIT | TRANE | 2015 | TAM7A0A24H21SCB | 13144AANAV | 2 TON R-410A | RECEIVING BAY CEILING MOUNTED | FILTERS 20"X20"X1"=2 |
| 317 | HVAC | ACU-3 | AIR CONDENSER UNIT | AMERICAN STANDARD | 2013 | 4TWB3024D1000AA | 132052W94F | R-410A | EXTERIOR NORTH SIDE PAD MOUNTED | |
| 317 | HVAC | AHU-7 | AIR HANDLING UNIT | TRANE | 2000 | TWEO24C140B0 | P345A341V | 6 TON R-22 | STORAGE OFFICE ABOVE CEILING | FILTER 20"X20"X1"=1 |
| 317 | HVAC | MSACU-3 | MINI-SPLIT AIR CONDENSER UNIT HP | MITSUBISHI ELECTRIC | 2015 | MXZ-2B20NA | 2007491 | 20,000 BTU R-410 | ROOF WEST END WALL MOUNTED | ONE CONDENSOR FOR TWO SPLIT AHU's |
| 317 | HVAC | MSAHU-3-1 | MINI-SPLIT AIR HANDLING UNIT | MITSUBISHI ELECTRIC | 2012 | MSZ-GE12NA | 30003437 | 1 TON R-410 | ROOM 121 BREAK ROOM SOUTH WALL 96" AFF | WASHABLE FILTER |
| 317 | HVAC | MSAHU-3-2 | MINI-SPLIT AIR HANDLING UNIT | MITSUBISHI ELECTRIC | 2012 | MSZ-GE09NA | 2022724 | 3/4 TON R-410 | ROOM 114 MIS OFFICE NORTH WEST CORNER 96" AFF | WASHABLE FILTER |
| 317 | HVAC | HVU-1 | HEATING VENTILATION UNIT | TRANE | 2008 | GSAA50GDBEON7BP10400 | C99H16397M | 10 TON 500,000 BTU | LOADING DOCK 2ND FLOOR | FILTERS 20"X20"X2"=6 |
| 317 | HVAC | HVU-2 | HEATING VENTILATION UNIT | TRANE | 2008 | GSAA50GDBEON7BP10400 | CH99H16395M | 10 TON 500,000 BTU | ROOM 104 CEILING MOUNTED ALONG NORTH WALL CENTER | FILTERS 20"X20"X2"=4 |
| 317 | HVAC | HVU-3 | HEATING VENTILATION UNIT | TRANE | 2008 | GSAA50GDBEON7BP10400 | CH99H16392M | 5 TON 200,000 BTU | ROOM 105 CEILING MOUNTED EAST WALL | FILTERS 20"X20"X2"=4 |
| 317 | HVAC | EF-1 | EXHAUST FAN POWER VENTILATOR WALL MOUNTED | FANTECH | 2023 | 5DDU085AY | 1008033360 | 115 VOLTS 1642 RPM 1/25 HP | MEN'S ROOM 115 WALL MOUNTED WEST WALL EXTERIOR | USED FOR MENS REST ROOM'S |
| 317 | HVAC | EF-2 | EXHAUST FAN DIRECT DRIVE CENTRIFUGAL DOWNBLAST CURB MOUNTED | GREENHECK | 2021 | G-099-B-6-1-19-X | 17924007 | 1/6 HP 1200 CFM 115 V | WOMENS ROOM 116 LOWER ROOF WEST SIDE CURB WOUNTED | USED FOR WOMENS REST ROOM'S |
| 317 | HVAC | EF-3 | EXHAUST FAN BELT DRIVE UPBLAST CENTRIFUGAL CURB MOUNTED | PENN VENTILATOR | 1990 | QB36 | DATA PLATE NOT LEGIBLE | 9845 CFM | HIGH ROOF ABOVE ROOM 101 WEST END CURB WOUNTED | POWER ROOF VENTILATORS |
| 317 | HVAC | EF-4 | EXHAUST FAN BELT DRIVE UPBLAST CENTRIFUGAL CURB MOUNTED | PENN VENTILATOR | 1990 | QB36 | DATA PLATE NOT LEGIBLE | 9845 CFM | HIGH ROOF ROOM 101 MIDDEL CURB WOUNTED | POWER ROOF VENTILATORS |
| 317 | HVAC | EF-5 | EXHAUST FAN BELT DRIVE UPBLAST CENTRIFUGAL CURB MOUNTED | PENN VENTILATOR | 1990 | QB36 | DATA PLATE NOT LEGIBLE | 9845 CFM | HIGH ROOF ABOVEROOM 101 EAST END CURB WOUNTED | POWER ROOF VENTILATORS |
| 317 | HVAC | EF-6 | EXHAUST FAN DIRECT DRIVE CENTRIFUGAL DOWNBLAST CURB MOUNTED | GREENHECK | CUBE-360-7 | 99H19022 | .75 HP 1800 RPM 9845 CFM | HIGH ROOF ABOVE ROOM 104 CURB WOUNTED | POWER ROOF VENTILATORS | |
| 317 | HVAC | EF-7 | EXHAUST FAN DIRECT DRIVE CENTRIFUGAL DOWNBLAST CURB MOUNTED | GREENHECK | CUBE-360-7 | 99H19023 | .75 HP 1800 RPM 9845 CFM | HIGH ROOF ABOVE ROOM 104 CURB WOUNTED | POWER ROOF VENTILATORS | |
| 317 | HVAC | EF-9 | EXHAUST FAN | AIR PERFORMANCE | 5KH32DN3085BX | D16J290031 | 1725 RPM | ROOM 103A WALL MOUNTED EAST WALL | ||
| 317 | PLUMBING | BFP-1 | BACKFLOW PREVENTER | WATTS | LF009M2QT | 116285 | 1.5" | WEST SIDE OF BLDG. CENTER UNDER COVER PAD MOUNTED | ||
| 317 | PLUMBING | BFP-2 | BACKFLOW PREVENTER | WATTS | 2023 | LF009M2QT | 094652 | 2" | WEST SIDE OF BLDG. NORTH END UNDER COVER PAD MOUNTED | |
| 317 | PLUMBING | WHE-1 | WATER HEATER ELECTRIC | WHIRLPOOL | EIFS0RD045V | 1010T426801 | 50 GALLON 4500 WATTS | ROOM 115 IN CLOSET BEHIND DOOR IN MENS ROON | ||
| 317 | PLUMBING | WHE-2 | WATER HEATER ELECTRIC | WHIRLPOOL | E2F30LD035V | 0938T430025 | 28 GALLON 3500 WATTS | ROOM 103A IN BAY UNDER SHELF MENS ROOM | ||
| 317 | GENERAL | DL-1 | DOCK LEVELER | RITE HITE | NO DATA PLATE | MECHANICAL | ROOM 106 SOUTH WALL EAST END | |||
| 317 | GENERAL | DL-2 | DOCK LEVELER | RITE HITE | NO DATA PLATE | MECHANICAL | ROOM 106 SOUTH WALL WEST END | |||
| 317 | GENERAL | DL-3 | DOCK LEVELER | RITE HITE | NO DATA PLATE | MECHANICAL | ROOM 105 SOUTH WALL WEST END | |||
| 317 | GENERAL | DL-4 | DOCK LEVELER | RITE HITE | NO DATA PLATE | MECHANICAL | ROOM 105 SOUTH WALL EAST END |
| 318 | ELECTRICAL | DTT-1 | DRY TYPE TRANSFORMER | GENERAL ELECTRIC | 1960 | 9T23Y3516 | NONE | 150 KVA 480 PRIME 120/208V | ROOM 120 WEST WALL | |
| 318 | ELECTRICAL | DTT-2 | DRY TYPE TRANSFORMER | FEDERAL PACIFIC | 2013 | T4T300BE | 222684 | 300 KVA 480/208/120 3 PHASE | ROOM 141 SOUTH WALL EAST END | |
| 318 | STAND-BY POWER | ATS-1 | AUTOMATIC TRANSFER SWITCH | CUMMINS | 2000 | OTPCC | J120403834 | 400 AMPS 208Y/120V 3 PHASE | WEST SIDE BEHIND GENERATOR | ANNUAL MAINTENANCE PERFORMED BY CUMMINS |
| 318 | STAND-BY POWER | GEN-1 | EMERGENCY GENERATOR | STAMFORD-ARK | 2013 | DSFAE-1333411 | G130535682 SPEC.E | 80 KW | SINGLE UNIT WEST SIDE BLDG | ANNUAL MAINTENANCE PERFORMED BY CUMMINS |
| 318 | STAND-BY POWER | GEN-1 | EMGERGENCY GENERATOR DIESEL ENGINE | CUMMINS | 2013 | QS85-G3 NR3 | 73547717 | 4.5 LITER 89 HP | ANNUAL MAINTENANCE PERFORMED BY CUMMINS | |
| 318 | STAND-BY POWER | FT-1 | FUEL TANK DIESEL | HENNIG | 2013 | CPG-AO43V606 | DATA PLATE NOT LEGIBLE | 340 GALLONS | ANNUALS PERFORMED BY PETROLEUM RECOVERY | |
| 318 | BOILER | BOILER-1 | BOILER [NATURAL GAS] | WEIL-McLAIN SLIMFIT | 2022 | SF2000 | 550201453 D | 2,000,000 MBH 120 VOLTS 23.2 AMPS | SOUTH EAST CORNER ROOM 104 CENTER ON PAD | ANNUALS PERFORMED BY ARGENT INSPECTIONS |
| 318 | HVAC | CMD-1 | CARBON MONOXIDE DETECTOR | FIRST ALERT | 2020 | CO606 | NONE | 120 VAC 9 VOLT BATT BACK-UP | ROOM 104 NORTH WALL CENTER | |
| 318 | BOILER | HWSP-5 | HOT WATER SUPPLY PUMP | TACO | 1998 | FF2010E2GIF2L0A | 09831 | 115 GPM | ROOM 120 SOUTH WALL PAD MOUNTED | |
| 318 | BOILER | HWSPM-5 | HOT WATER SUPPLY PUMP MOTOR | CENTURY | 1998 | 8501190J | 030126M | 5 HP 1760 RPM | ||
| 318 | BOILER | HWRP-4 | HOT WATER RETURN PUMP | TACO | 1999 | FE2007E2C1E2LCA | 218551 | 115 GPM | ROOM 120 SOUTH WALL PAD MOUNTED | |
| 318 | BOILER | HWRPM-4 | HOT WATER RETURN PUMP MOTOR | BALDOR | 1999 | M3154T | F499 | HP 1.5 1760 RPM | ||
| 318 | HVAC | SF-1 | SHOT FEEDERS | NEPTUNE | 1999 | NO DATA PLATE | 2 GALLON | ROOM 145 WEST SIDE | ||
| 318 | HVAC | SF-2 | SHOT FEEDERS | NEPTUNE | 1999 | NO DATA PLATE | 3 GALLON | ROOM 120 SOUTH WALL | ||
| 318 | HVAC | CHILLER-1 | CHILLER RTWA | TRANE | 2006 | RTWA0904YE01D3DOWNT | U01M02610 | 90 TON LIQUID COOLED R-22 | ROOM 145 CENTER | |
| 318 | HVAC | CTWR-1 | COOLING TOWER | SPX/MARLELY | 2005 | AQ-10048741-A1 496K | NC2211SS | 90 TON | WEST SIDE EXTERIOR BY ROOM 103 | |
| 318 | HVAC | CTEH-1 | COOLING TOWER EMMERSION HEATER | INDUSTRIAL ENGINEERING AND EQUIPMENTCOMPANY | 2011 | Q7131ZU176452 | NONE | 3 PHASE 460 VOLTS 3000 WATTS | WEST SIDE EXTERIOR BY ROOM 103 INSIDE TOWER TANK | |
| 318 | HVAC | CONDWSP-1 | CONDENSER WATER SUPPLY PUMP | ARMSTRONG | 2008 | BF-SPD | 693771 | 270 GPM 1800 RPM | ROOM 145 NORTH SIDE CENTER PAD MOUNTED | |
| 318 | HVAC | CONDWSPM-1 | CONDENSER WATER SUPPLY PUMP MOTOR | ARMSTRONG | 2008 | 005180T3E184TC | LR38324 | 5 HP 1755 RPM | ||
| 318 | HVAC | CWSP-2 | CHILLED WATER SUPPLY PUMP | TACO | 2010 | FE2507E2F1F2L0A | 4422 | 260 GPM 115 GPM | ROOM 145 SOUTH SIDE CENTER PAD MOUNTED | |
| 318 | HVAC | CWSPM-2 | CHILLED WATER SUPPLY PUMP MOTOR | BALDOR | 2010 | M3218T | F-699 | 5 HP 1760 RPM | ||
| 318 | HVAC | CWSP-3 | CHILLED WATER SUPPLY PUMP | TACO | 1998 | FE2010E261F2EOA | 209831 | 260 GPM 115 GPM | ROOM 145 SOUTH SIDE CENTER PAD MOUNTED | CHILL WATER SUPPLY FOR BLDG. 358 |
| 318 | HVAC | CWSPM-3 | CHILLED WATER SUPPLY PUMP MOTOR | BALDOR | 1998 | M3311T | F-199 | 7.5 HP 1760 RPM | CHILL WATER SUPPLY FOR BLDG. 358 | |
| 318 | HVAC | ET-1 | EXPANSION TANK | DATA PLATE COVERED BY INSULATION | 1998 | DATA PLATE COVERED BY INSULATION | 600 GALLONS | ROOM 145 SOUTH WALL | ||
| 318 | HVAC | ET-2 | EXPANSION TANK | DATA PLATE COVERED BY INSULATION | 1998 | DATA PLATE COVERED BY INSULATION | 120 GALLONS | ROOM 145 SOUTH WALL | ||
| 318 | HVAC | ET-3 | EXPANSION TANK | DATA PLATE COVERED BY INSULATION | 1998 | DATA PLATE COVERED BY INSULATION | 30 GALLONS | ROOM 145 SOUTH WALL | ||
| 318 | HVAC | ET-4 | EXPANSION TANK | DATA PLATE COVERED BY INSULATION | 1998 | DATA PLATE COVERED BY INSULATION | 120 GALLONS | ROOM 120 SOUTH EAST CORNER | ||
| 318 | HVAC | CAU-1 | CHEMICAL ANALYSIS UNIT | WALLCHEM | WCTW100PN-B | 1805030249 | 7 AMPS 100-200 V/AC | ROOM 145 WEST SIDE | ||
| 318 | HVAC | CHEMP-1 | ELECTRONIC METERING PUMP | PULSAtron | LC640A-PHC1-XXX SERIES T7 | 9912103955 | 22 GDR 80 PSI 1 PHASE | ROOM 145 WEST SIDE | ||
| 318 | HVAC | CHEMP-2 | ELECTRONIC METERING PUMP | PULSAtron | LC845A-PHC1-XXX SERIES C | 9912103956 | 30 GDR 100 PSI 1 PHASE | ROOM 145 WEST SIDE | ||
| 318 | HVAC | FDM-1 | FREON DETECTION MONITOR | TRANE | RMWFRPAO0000AD | L99HO3367M | 30 WATT | ROOM 145 EAST WALL 60" AFF BY CHILLER | CONNECTED TO EXHAUST FAN #4 FOR FREON EVACUATION | |
| 318 | HVAC | MSACU-1 | MINI-SPLIT AIR CONDENSER UNIT HP | MITSUBISHI ELECTRIC | 2005 | MXZ-2C20NA2 | 89P06603 | 2 TON R-410A | ROOF ABOVE ROOM 110 LOWER ROOF NORTH WALL WEST END | |
| 318 | HVAC | MSAHU-1 | MINI-SPLIT AIR HANDLING UNIT | MITSUBISHI ELECTRIC | 2005 | MSY-GE24NA | 2005662 | 2 TON R-410A | ROOM 129A WEST WALL | WASHABLE FILTER |
| 318 | HVAC | MSACU-2 | MINI-SPLIT AIR CONDENSER UNIT HP | MITSUBISHI ELECTRIC | 2003 | MUY-GE24NA | P1LW700061 | 1.5 TON R-22 | ROOF ABOVE ROOM 110 LOWER ROOF NORTH WALL WEST END | SPLIT BETWEEN 2 AHU's |
| 318 | HVAC | MSAHU-2A | MINI-SPLIT AIR HANDLING UNIT | MITSUBISHI ELECTRIC | 2003 | MSZ-GL09NA | 83E15355 | 3/4 TON R-22 | ROOM 131 EOC EAST WALL 84" AFF | WASHABLE FILTER |
| 318 | HVAC | MSAHU-2B | MINI-SPLIT AIR HANDLING UNIT | MITSUBISHI ELECTRIC | 2003 | MSZ-GL09NA | 87N13540 | 3/4 TON R-22 | ROOM 131 EOC EAST WALL 84" AFF | WASHABLE FILTER |
| 318 | HVAC | MSACU-3 | MINI-SPLIT AIR CONDENSER UNIT HP | FUJITSU | 2008 | AOU12RLS | HSN014756 | 1 TON R-410A | WALL MOUNTED ABOVE HIGH ROOF ABOVE ROOM 128 NORTH WALL | |
| 318 | HVAC | MSAHU-3 | MINI-SPLIT AIR HANDLING UNIT | FUJITSU | 2008 | ASU12RLS | HSA014912 | 1 TON R-410A | ROOM 108 EAST WALL 84" AFF | WASHABLE FILTER |
| 318 | HVAC | PCKU-1 | PACKAGED UNIT HP | LUXAIRE | 2020 | PHE4B3631B | W169310960 | 3 TON R-410A | PAD MOUNTED NORTH WALL OUTSIDE ROOM 144 | FILTERS 24"X24"X1"=2 |
| 318 | HVAC | PTAC-1 | PACKAGE TERMINAL AIR CONDITIONING UNIT HP | LG | 2021 | LP123HDUC1 | 3831A20145E | 10,500 BTU COOL 300 BTU HEAT R410-A | ROOM 146 NORTH WALL 16" AFF MAIL ROOM | WASHABLE FILTER |
| 318 | HVAC | ACC-1 | AIR CONDENSER UNIT | LIEBERT | 2013 | TCDV251-YS5910 | C12E4F2167 | 12-25 TON R-407C | NORTH SIDE OUTSIDE MAIL ROOM 103 | |
| 318 | HVAC | AHU- CRU-1 | COMPUTER ROOM UNIT | LIEBERT | 2013 | DS042ADC0E1085S | C12D8E0002 | 12 TON R-407C | INSIDE SERVER ROOM 129 | FILTERS 16"X25"X4"=5 |
| 318 | HVAC | ACC-2 | AIR CONDENSER UNIT | LIEBERT | 2013 | TCDV251-YS5910 | C12E4F2166 | 12 TON R-407C | ROOM 103 NORTH SIDE OUTSIDE MAIL ROOM | |
| 318 | HVAC | AHU-2 CRU-2 | COMPUTER ROOM UNIT | LIEBERT | 2013 | DS042ADC0EI0859 | C12D8E001 | 12-25 TON R-407C | INSIDE SERVER ROOM 129A | FILTERS 16"X25"X4"=5 |
| 318 | HVAC | AHU-1/AHU-9 | AIR HANDLING UNIT COOLING COIL MODULE | TRANE | 1996 | MCCA021CAK0B0C0A | K99H51334N K99H51335N K99H51336N K99H51337N | 18 TONS WATER 10,000 CFM | ROOM 120 NORTH WEST CORNER | UNIT IS COMPOZED OF 4 INDIVIDUAL BOXES BLOWER, COIL, FILTER, INTAKE FILTERS 16"X20"X2"=8 16"X25"X2"=4 |
| 318 | HVAC | AHU-2/AHU-10 | AIR HANDLING UNIT COOLING COIL MODULE | TRANE | 1996 | MCCA017HBEOAOAC00 | K99H51341N K99H51342N K99H51343N K99H51344N | 18 TONS WATER 10,000 CFM | ROOM 141 WEST WALL CENTER | UNIT IS COMPOZED OF 4 INDIVIDUAL BOXES BLOWER, COIL, FILTER, INTAKE FILTERS 16"X20"X2"=8 16"X25"X2"=4 |
| 318 | HVAC | ACU-2 HP-2 | HEAT PUMP DX OUTDOOR UNIT | CARRIER | 2007 | DATA PLATE NOT LEGIBLE | 3-4 TON R-410A | EXTERIOR WEST WALL BY GENERATOR | ||
| 318 | HVAC | AHU-2 | AIR HANDLING UNIT | CARRIER | 2007 | FY4ANF036 | 0207A82174 | 2.5 TON 1/3 HP R-410A | ROOM 133 CENTER ABOVE DROP CEILING | FILTER 20"X20"X1"=1 |
| 318 | HVAC | HVU-1 | HEATING VENTILATION UNIT | TRANE | 1996 | MCCA021BAJ0B0CA | K99H51381N K99H51382N K99H51383N K99H51384N | 18 TONS WATER 212K BTU | PENTHOUSE 1 HIGH ROOF CENTER LINE WEST END | UNIT IS COMPOZED OF 4 INDIVIDUAL BOXES BLOWER, COIL, FILTER, INTAKE FILTERS 16"X24"X2"=12 |
| 318 | HVAC | HVU-2 | HEATING VENTILATION UNIT | TRANE | 1996 | MCCA021BAJ0B0CA | K99H51391N K99H51392N K99H51393N K99H51394N | 18 TONS WATER 172K BTU | PENTHOUSE 2 HIGH ROOF CENTER LINE EAST END | UNIT IS COMPOZED OF 4 INDIVIDUAL BOXES BLOWER, COIL, FILTER, INTAKE FILTERS 16"X24"X2"=12 |
| 318 | HVAC | UHS-1 | UNIT HEATER HOT WATER | TRANE | 2010 | UHSA070S8DAAE | C99H46273M | 91,000 BTU STEAM 1740 CFM | ROOM 120 SOUTH WALL EAST END 96" AFF | |
| 318 | HVAC | UHS-2 | UNIT HEATER HOT WATER | TRANE | 2010 | UHSA070S8DAAE | C99H46272M | 91,000 BTU STEAM 1740 CFM | ROOM 145 SOUTH WALL CENTER 96" AFF | |
| 318 | HVAC | UHS-3 | UNIT HEATER HOT WATER | TRANE | 2010 | UHSA070S8DAAE | C99H45274M | 91,000 BTU STEAM 1740 CFM | ROOM 141 EAST WALL CENTER 96" AFF | |
| 318 | HVAC | VAV 1-1 | VARIABLE AIR VOLUME BOX | TRANE | 2015 | R99H45576N | 277 V 1050 RPM | ROOM 133 CEILING MOUNTED SOUTH END | DDC ADDRESS 14 FILTER 20"X20"X1"=1 | |
| 318 | HVAC | VAV 1-2 | VARIABLE AIR VOLUME BOX | TRANE | 2015 | ROOM 131 CEILING MOUNTED NORTH EAST CORNER | DDC ADDRESS 22 FILTER 20"X20"X1"=1 | |||
| 318 | HVAC | VAV 1-3 | VARIABLE AIR VOLUME BOX | TRANE | 2015 | ROOM 112 CEILING MOUNTED HALLWAY OUTSIDE | DDC ADDRESS 18 FILTER 20"X20"X1"=1 | |||
| 318 | HVAC | VAV 1-4 | VARIABLE AIR VOLUME BOX | TRANE | 2015 | VPWE17112U00200WDD003000000000 | R99H45569N | 277 V 1050 RPM | ROOM 105 CEILING MOUNTED 6' INSIDE ENTRANCE DOOR | DDC ADDRESS 17 FILTER 20"X20"X1"=1 |
| 318 | HVAC | VAV 1-5 | VARIABLE AIR VOLUME BOX | TRANE | 2015 | ROOM 109 CEILING MOUNTED NORTH EAST CORNER | DDC ADDRESS 16 FILTER 20"X20"X1"=1 | |||
| 318 | HVAC | VAV 1-6 | VARIABLE AIR VOLUME BOX | TRANE | 2015 | ROOM 111 CEILING MOUNTED NORTH WEST CORNER | DDC ADDRESS 15 FILTER 20"X20"X1"=1 | |||
| 318 | HVAC | VAV 1-7 | VARIABLE AIR VOLUME BOX | TRANE | 2015 | ROOM 113 CEILING MOUNTED HALLWAY OUTSIDE JT CONFRENCE ROOM | DDC ADDRESS 13 FILTER 20"X20"X1"=1 | |||
| 318 | HVAC | VAV 1-8 | VARIABLE AIR VOLUME BOX | TRANE | 2015 | ROOM 115 CEILING MOUNTED CONFRENCE ROOM SOUTH SIDE CENTER | DDC ADDRESS 12 FILTER 20"X20"X1"=1 | |||
| 318 | HVAC | VAV 1-9 | VARIABLE AIR VOLUME BOX | TRANE | 2015 | OUTSIDE ROOM 127 | DDC ADDRESS 14 FILTERS 20"X20"X1"=2 | |||
| 318 | HVAC | VAV 1-10 | VARIABLE AIR VOLUME BOX | TRANE | 2015 | CEILING MOUNTED HALLWAY OUTSIDE CONFRENCE ROOM DOOR EAST SIDE | DDC ADDRESS 5 FILTER 20"X20"X1"=1 | |||
| 318 | HVAC | VAV 2-1 | VARIABLE AIR VOLUME BOX | TRANE | 2015 | ROOM 137 CEILING MOUNTED | DDC ADDRESS 6 FILTER 15"X20"X1"=1 | |||
| 318 | HVAC | VAV 2-2 | VARIABLE AIR VOLUME BOX | TRANE | 2015 | ROOM 138 CEILING MOUNTED | DDC ADDRESS 7 FILTER 20"X20"X1"=1 | |||
| 318 | HVAC | VAV 2-3 | VARIABLE AIR VOLUME BOX | TRANE | 2015 | ROOM 200H HALLWAY CEILING MOUNTED | DDC ADDRESS 8 FILTER 20"X20"X1"=1 | |||
| 318 | HVAC | VAV 2-4 | VARIABLE AIR VOLUME BOX | TRANE | 2015 | ROOM 201 CLASSROOM CEILING MOUNTED WEST END | DDC ADDRESS 9 FILTER 20"X20"X1"=1 | |||
| 318 | HVAC | EF-2 | EXHAUST FAN DIRECT DRIVE SQUARE CENTRIFUGAL INLINE FAN | GREENHECK CAP SAYS TWIN CITY FAN & BLOWER | 2000 | SQ-75D | 12887298 | 30 WATT 1300 RPM 115 V 12" DIA | EXHAUSTS TO MEDIUM ROOF BETWEEN PENTHOUSES ABOVE ROOM 125 IN-LINE FAN LOCATED 2ND FLOOR ATTIC OVER SERVER ROOM 129 SOUTH END | NOT ON PRINT |
| 318 | HVAC | EF-3 | EXHAUST FAN BELT DRIVE UPBLAST CENTRIFUGAL ROOF MOUNTED | GREENHECK | 2012 | CUBE-101H-4-F | 12887249 1206 | .25 HP 1800 RPM 18" DIA | MEDIUM ROOF CENTER SOUTH EDGE ABOVE SERVER ROOM 129 NORTH END CURB MOUNTED | NOT ON PRINT |
| 318 | HVAC | EF-4 | EXHAUST FAN BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | 2000 | GB-130-5X-QD | 99H15491 | .5 HP 1800 RPM 18" DIA | LOWER ROOF WEST END ABOVE ROOM 145 TIED INTO FREON DETECTION ALARM R-22 EVACUATION | ON PRINT # 12 |
| 318 | HVAC | EF-5 | EXHAUST FAN DIRECT DRIVE SQUARE CENTRIFUGAL | BROAN | DENERGIZED ON 3-2-2021 NO LONGER NEEDED BY ORDER OF CHRISTOPHER DAVENPORT | 8" DIA | ROOM 146 MAIL ROOM SOUTH WEST CORNER CEILING MOUNTED | OFFLINE | ||
| 318 | HVAC | EF-7 | EXHAUST FAN BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | 2000 | GB-100-4X-QD-2A | 99H19977 | .25 HP 791-1249 CFM 115 V 18" DIA | SOUTH SIDE OF HIGH ROOF CENTER ABOVE CLASS ROOM REST ROOMS 203 + 204 | ON PRINT # 7 |
| 318 | HVAC | EF-8 | EXHAUST FAN BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | 2000 | GB-100-4 | 99H18722 | .25 HP 1800 RPM 18" DIA | MEDIUM ROOF EAST END OVER REST ROOM 118 CURB MOUNTED | ON PRINT # 08 |
| 318 | HVAC | EF-10 | EXHAUST FAN BELT DRIVE CENTRIFUGAL WALL AXIAL FAN | AMERICAN COOLAIR CORP | 2000 | C24Q | 278665 | 12" DIA | ROOM 141 EAST WALL SOUTH END 96" AFF WALL MOUNTED | ON PRINT # 10 |
| 318 | HVAC | EF-11 | EXHAUST FAN SQUARE IN LINE DUCT FAN CEILING MOUNTED | GREENHECK | ROOM 126 IN-LINE FAN FOR BATTERY EXHAUST 144" AFF EAST WALL CEILING MOUNTED | ON PRINT # 11 | ||||
| 318 | HVAC | EF-13 | EXHAUST FAN BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | 2000 | GB-100-4X-QD-2A | 99H13377 | .25 HP 791-1249 CFM 115 V 18" DIA | LOWER ROOF WEST END ABOVE ROOM 100A FOR REST ROOM'S CURB MOUNTED | ON PRINT # 13 |
| 318 | HVAC | EF-16 | EXHAUST FAN BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | 2000 | GB-360-7-X | 96B09023 | 36" DIA | CEILING MOUNTED IN ROOM 126 | ON PRINT # 16 |
| 318 | HVAC | EF-18 | EXHAUST FAN BELT DRIVE AXIAL FAN | GREENHECK | 2000 | SBE 7.54DGE | 472453 | .25 HP 1800 RPM 18" DIA | WALL MOUNTED ABOVE SINK ROOM 144 WEST WALL 74" AFF | NOT ON PRINT |
| 318 | HVAC | SF-2 | SUPPLY FAN BELT DRIVE SQUARE CENTRIFUGAL IN-LINE | GREENHECK | 1996 | BSQ-120-5 | COVERED | .5 HP 877-1292 CFM 115 V 13" DIA | ROOM 120 ABOVE CATWALK SOUTH WALL IN-LINE DUCT FOR AHU #1 | |
| 318 | HVAC | SF-3 | SUPPLY FAN BELT DRIVE SQUARE CENTRIFUGAL IN-LINE | GREENHECK | 1996 | BSQ-80-5 | 99H19209 | .25 HP 242-756 CFM 115 V 11" DIA | ROOM 141 NORTH WALL EAST END IN-LINE DUCT 96" AFF FOR AHU #2 | TRANE CONTROLLED |
| 318 | HVAC | SF-4 | SUPPLY FAN BELT DRIVE PROPELLER AXIAL WALL FAN | GREENHECK | 2000 | SBS-1L20-4 | 99H19192 | .25 HP 1800 RPM 18" DIA | ROOM 120 ABOVE CATWALK SOUTH WALL | TRANE CONTROLLED |
| 318 | HVAC | OADMP-1 | OUTSIDE AIR DAMPER | BARBER COLMAN COMPANY | MA-418-0-0-3 | 9519 | 48"X48" .9 AMP | ROOM 126 EAST WALL NORTH SIDE TIED INTO EXHAUST FAN #11 | ||
| 318 | PLUMBING | BFP-1 | BACKFLOW PREVENTER | WATTS | 007 M1QT | 77225 | 2" | OUTSIDE MAIN ENTRANCE SOUTH WALL UNDER COVER | ||
| 318 | PLUMBING | BFP-2 | BACLFLOW PREVENTER | WATTS | 007-2DC | 11071 | 2" | ROOM 145 SOUTH WALL 36" AFF | ||
| 318 | PLUMBING | BFP-3 | BACKFLOW PREVENTER | WATTS | 007QT | 10108 | 1.5" | OUTSIDE ROOM 120 SOUTH WALL UNDER COVER | ||
| 318 | PLUMBING | BFP-4 | BACKFLOW PREVENTER | WATTS | 007M1QT | 171755 | 1" | ROOM 145 EAST WALL 102" AFF ABOVE COMPRESSOR | ||
| 318 | PLUMBING | BFP-5 | BACKFLOW PREVENTER | WATTS | 007M1-QT | 154112 | 1" | ROOM 120 SOUTH WALL 96" AFF ABOVE PUMPS | ||
| 318 | PLUMBING | BFP-6 | BACKFLOW PREVENTER | WATTS | 007M3QT | 296609 | 3/4" | ROOM 129A UNDER COMPUTER DECKING EAST WALL | ||
| 318 | PLUMBING | BFP-7 | BACKFLOW PREVENTER | WATTS | LF007M2QT | 9612 | 1.5" | |||
| 318 | PLUMBING | EWS-1 | EYEWASH STATION | ENCON SAFETY PRODUCTS | NO DATA PLATE | 12' BOWL | WAREHOUSE BY ROOM 102E WALL MOUNT | |||
| 318 | PLUMBING | EWS-2 | EYEWASH STATION | GUARDIAN | NO DATA PLATE | 12' BOWL | ROOM 142 SOUTH WEST CORNER | |||
| 318 | PLUMBING | WHE-1 | WATER HEATER ELECTRIC | WHIRLPOOL | 2000 | E2F40LDO45V | 0945T426332 | 9 KW 38 GAL | ROOM 118A JANITORS CLOSET SOUTH EAST CORNER WALL MOUNT | |
| 318 | PLUMBING | WHE-2 | WATER HEATER ELECTRIC | GENERAL ELECTRIC | 2008 | PE40M9A | GE 0801C08222 | 9 KW 40 GAL | ROOM 145 SOUTH EAST CORNER | |
| 318 | PLUMBING | WHE-3 | WATER HEATER ELECTRIC [INSTANTANEOUS] | Eemax | 2023 | SPEX3512 | 3014847 | 3.5 kw 120v | ROOM 144 UNDER SINK COMMANDERS RESTROOM | INSTA-HOT |
| 318 | PLUMBING | WHE-4 | WATER HEATER ELECTRIC [INSTANTANEOUS] | Eemax | 2023 | ROOM 111A BREAK ROOM UNDER SINK | INSTA-HOT | |||
| 318 | PLUMBING | WHE-5 | WATER HEATER ELECTRIC | RHEEM | HE40M1A | HP 0702B21122 | 40 GAL 240/208 VOLTS | 2ND FLOOR MENS ROOM BEHIND DOOR. | ||
| 318 | PLUMBING | WF-1 | WATER FOUNTIAN | ELKAY | FD700 3 1H | 070320780 | R-134A | WAREHOUSE BY ROOM 102E STAND ALONE | NON-FILTERED | |
| 318 | PLUMBING | WF-2 | WATER FOUNTIAN | HALSEY TAYLOR | 2020 | HAC-HB-1B | 180926503 | 1/5 HP R-134A 115 VOLTS | HALLWAY OUTSIDE RESTROOMS WALL MOUNTED | WATER FILTER SENTRY PLUS # 55898C |
| 318 | PLUMBING | SP-1 | SUMP PUMP | GOULDS | 1992 | DATA PLATE NOT LEGIBLE | 2424360 | 1.5" PIPE | EXTERIOR IN PIT SOUTH SIDE OF COOLING TOWER |
| 320 | ELECTRICAL | DTT-1 | DRY TYPE TRANSFORMER | GENERAL ELECTRIC | 9T23Y3512 | NONE | 45 KVA 480 208Y/120V 3 PHASE | ROOM 119 SOUTH WALL OUTSIDE ROOM 118A WALL MOUNTED 10' AFF | ||
| 320 | ELECTRICAL | DTT-2 | DRY TYPE TRANSFORMER | GENERAL ELECTRIC | 9T23Y3873 | XY | 46 KVA 480 208Y/120V 3 PHASE | ROOM 119 SOUTH WALL OUTSIDE 116 FLOOR MOUNTED | ||
| 320 | ELECTRICAL | DTT-4 | DRY TYPE TRANSFORMER | CHALLENGER | DT3 MODEL 5 452-415B | J95K3261 | 47 KVA 480 208Y/120V 3 PHASE | ROOM 110 EAST WALL SOUTH END FLOOR MOUNTED | ||
| 320 | ELECTRICAL | DTT-5 | DRY TYPE TRANSFORMER | GENERAL ELECTRIC | 9T23Y3513 | NONE | 48 KVA 480 208Y/120V 3 PHASE | ROOM 110 EAST WALL NORTH END FLOOR MOUNTED | ||
| 320 | ELECTRICAL | DTT-6 | DRY TYPE TRANSFORMER | SQUARE D | EX45T3H | 1081816244 | 49 KVA 480 208Y/120V 3 PHASE | ROOM 101 NORTH WALL WEST END FLOOR MOUNTED | ||
| 320 | ELECTRICAL | DTT-7 | DRY TYPE TRANSFORMER | GENERAL ELECTRIC | 9T21A1007 | RY | 5 KVA 480/240/120 | ROOM 101 NORTH WALL CENTER 6' AFF WALL MOUNTED | ||
| 320 | ELECTRICAL | DTT-8 | DRY TYPE TRANSFORMER | GENERAL ELECTRIC | 9T23Y3513 | 9965835 | 49 KVA 480 208Y/120V 3 PHASE | ROOM 110 WEST WALL NORTH END MOUNTED ON COLUMN OUTSIDE ROOM 118 | ||
| 320 | HVAC | ACU-1 [HP-1] | AIR CONDENSER UNIT HP | TRANE | 2022 | 4TWR6024H1000AD | 22342MH44F | 2 TON R-410A 208/230 VOLTS 14 AMPS | ROOF MOUNTED LOWER ROOF OVER ROOM 106 NORTH EAST CORNER | |
| 320 | HVAC | AHU-1 [HP-1] | AIR HANDLING UNIT | TRANE | 2022 | GAM5BOB30M21EAB | 22243W8E1V | 2 TON R-410A 200-230 V 1/3 HP | MEZZAINE ABOVE ROOM 105 NORTH WALL | DDC ADDRESS# 4 FILTERS 20"X20"X1"=2 |
| 320 | HVAC | ACU-2 [HP-2] | AIR CONDENSER UNIT HP | TRANE | 2022 | 4TWR6024H1000AD | 22342NAR4F | 2 TON R-410A 208/230 VOLTS 14 AMPS | ROOF MOUNTED OVER ROOM 106 SOUTH WALL | |
| 320 | HVAC | AHU-2 [HP-2] | AIR HANDLING UNIT | TRANE | 2022 | GAM5BOB30M21EAB | 22285KRL1V | 2 TON R-410A 200-230 V 1/3 HP | MEZZAINE ABOVE ROOM 107 NORTH WALL | DDC ADDRESS# 3 FILTERS 20"X20"X2" |
| 320 | HVAC | ACU-3 [HP-3] | AIR CONDENSER UNIT HP | TRANE | 2022 | 4TWR6024H1000AD | 22364T224F | 2 TON R-410A 208/230 VOLTS 14 AMPS | WEST SIDE LOW ROOF ABOVE ROOM 117 NORTH END | |
| 320 | HVAC | AHU-3 [HP-3] | AIR HANDLING UNIT | TRANE | 2022 | GAM5BOA18M11EAB | 22304NHJ1V | 1.5 TON R-410A 200-230 V 1/3 HP | MEZZAINE ABOVE ROOM 117A | DDC ADDRESS# 13 FILTER 20"X20"X1"=1 |
| 320 | HVAC | ACU-4 [HP-4] | AIR CONDENSER UNIT HP | TRANE | 2022 | 4TWR6024H1000AD | 22342M804F | 2 TON R-410A 208/230 VOLTS 14 AMPS | WEST SIDE LOW ROOF ABOVE ROOM 117 SOUTH END | |
| 320 | HVAC | AHU-4 [HP-4] | AIR HANDLING UNIT | TRANE | 2022 | GAM5BOB30M21EAB | 2 TON R-410A 208/230 VOLTS 14 AMPS | MEZZAINE ABOVE ROOM 117 | DDC ADDRESS#14 FILTER 20"X20"X1"=1 | |
| 320 | HVAC | ACU-5 [HP-5] | AIR CONDENSER UNIT HP | TRANE | 2022 | 4TWR6024H1000AD | 22342NAD4F | 2 TON R-410A 208/230 VOLTS 14 AMPS | SOUTH SIDE EXTERIOR ROOM 114 PAD MOUNTED | |
| 320 | HVAC | AHU-5 [HP-5] | AIR HANDLING UNIT | TRANE | 2022 | GAM5BOB30M21EAB | 22134N7Y1V | 2 TON R-410A 200-230 V 1/3 HP | MEZZAINE OVER ROOM 112 WEST SIDE WOMENS RESTROOM | DDC ADDRESS# 5 FILTER 20"X20"X1"=1 |
| 320 | HVAC | UHE-8 | UNIT HEATER ELECTRIC | TASKMASTER | P3P5105CA1N | LN60721-033 | 5 KW | RISER ROOM 121 WEST WALL CENTER 74" AFF | T-STAT CONTROLLED | |
| 320 | HVAC | HVU-10 | HEATING VENTILATION UNIT [DUEL BURNER UNITS] | TRANE | 1999 | GSND030AD-M | C99H16396M | 600,000 BTU GAS 6000 CFM | MEZZINE ABOVE ROOM 114 NORTH EAST CORNER | TRANE # (HV-4) DDC ADDRESS# 9 FILTERS 16"X20"X2"=4 20"X20"X2"=2 |
| 320 | HVAC | HVU-11 | HEATING VENTILATION UNIT [DUEL BURNER UNITS] | TRANE | 1999 | GSND030AD-M | C99H16397M | 600,000 BTU GAS 6000 CFM | MEZZAINE ABOVE ROOM 117 SOUTH END | TRANE # (HV-1) DDC Address# 6 FILTERS 16"X20"X2"=4 20"X20"X2"=2 |
| 320 | HVAC | HVU-12 | HEATING VENTILATION UNIT [DUEL BURNER UNITS] | TRANE | 1999 | GSND030AD-M | C99H16398M | 600,000 BTU GAS 6000 CFM | ROOM 119 CEILING MOUNTED BETWEEN ROOMS 108 AND 117A | TRANE # (HV-3) DDC ADDRESS# 2 FILTERS 16"X20"X2"=4 20"X20"X2"=2 |
| 320 | HVAC | HVU-13 | HEATING VENTILATION UNIT [DUEL BURNER UNITS] | TRANE | 1999 | GSND030AD-M | C99H16401M | 500,000 BTU GAS 6000 CFM | MEZZAINE ABOVE ROOM 117 SOUTH END | TRANE # (HV-2) DDC ADDRESS# 7 FILTERS 20"X20"X2"=4 |
| 320 | HVAC | HVU-14 | HEATING VENTILATION UNIT [DUEL BURNER UNITS] | TRANE | 1999 | GSND030AD-M | C99H16400M | 200,000 BTU GAS 4900 CFM | MEZZAINE ABOVE ROOM 113 SOUTH WEST CORNER | TRANE # (HV-5) DDC ADDRESS# 12 FILTERS 20"X20"X2"=4 |
| 320 | HVAC | CDP-1 | CONDENSATE DRAIN PUMP | HARTELL PUMPS | KTEX-2UL | NONE | .9 AMPS 230 V | MEZZAINE ABOVE ROOM 117 FOR AHU/HP-4 | ||
| 320 | HVAC | CDP-2 | CONDENSATE DRAIN PUMP | LITTLE GIANT | 554917 | 11F142711573W | .9 AMPS 230 V | MEZZAINE ABOVE ROOM 117 FOR AHU/HP-3 | ||
| 320 | HVAC | EF-1 | EXHAUST FAN WALL MOUNTED PROPELLER FAN | DAYTON | 4UX59 | E47479 | 36"DIA .5 HP 825 RPM | ROOM 119 NORTH WALL WEST END | DDC ADDRESS# 10 | |
| 320 | HVAC | EF-2 | EXHAUST FAN WALL MOUNTED PROPELLER FAN | DAYTON | 4UX59 | E47479 | 36"DIA .5 HP 825 RPM | ROOM 119 NORTH WALL EAST END | ||
| 320 | HVAC | EF-3 | EXHAUST FAN WALL MOUNTED PROPELLER FAN | GREENHECK | 508-D | H 990723247A | 120 V 1.7 AMPS 270 CFM | ROOM 104A NORTH SIDE WALL MOUNTED | ||
| 320 | HVAC | EF-4 | EXHAUST FAN DIRECT DRIVE CENTRIFUGAL DOWNBLAST CURB MOUNTED | GREENHECK | GW-90-D-X | 96B08731 | 36" DIA | ROOM 110 EAST WALL SOUTH END 96" AFF WALL MOUNTED | ||
| 320 | HVAC | EF-5 | EXHAUST FAN DIRECT DRIVE VAIN AXIAL | GREENHECK | NO DATA PLATE | ??? | ROOM 112 RESTROOM SOUTH SIDE WALL MOUNTED | |||
| 320 | HVAC | EF-6 | EXHAUST FAN WALL MOUNTED PROPELLER FAN | DAYTON | 4UX59 | E47479 | 36" DIA .5 HP 825 RPM | ROOM 118 SOUTH WALL 96" AFF WALL MOUNTED | DDC ADDRESS# 11 | |
| 320 | HVAC | EF-7 | EXHAUST FAN WALL MOUNTED PROPELLER FAN | GREENHECK | NO DATA PLATE | 18" DIA | ROOM 107A RESTROOM CURB MOUNTED | ~ TSTAT, ON/OFF CONTROL IN METASYS | ||
| 320 | HVAC | EF-10 | EXHAUST FAN DIRECT DRIVE CENTRIFUGAL DOWNBLAST CURB MOUNTED | GREENHECK | GW-90-D-X | 96B08730 | 18" DIA | ROOM 110 SOURH EAST CORNER 120" AFF WALL MOUNTED | DDC ADDRESSS# 1 EXHAUST FOR BATTERY CHARGING STATIONS | |
| 320 | HVAC | EF-12 | EXHAUST FAN DIRECT DRIVE CENTRIFUGAL DOWNBLAST CURB MOUNTED | GREENHECK | NO DATA PLATE | 18" DIA | ROOM 113 WEST SIDE LOWER ROOF CURB MOUNTED | |||
| 320 | HVAC | EF-13 | EXHAUST FAN DIRECT DRIVE CENTRIFUGAL DOWNBLAST CURB MOUNTED | GREENHECK | NO DATA PLATE | 24" DIA | ABANDONED IN PLACE POWER SUPPLIES HAVE BEEN REMOVED TIED INTO AIR COMPRESSOR THAT WAS REMOVED | |||
| 320 | HVAC | EF-14 | EXHAUST FAN DIRECT DRIVE CENTRIFUGAL DOWNBLAST CURB MOUNTED | GREENHECK | GW-09-D-X | DATA PLATE NOT LEGIBLE | 4' DIA 20,000 CFM | HIGH ROOF MOUNTED ABOVE ROOM 110 NORTH WEST CORNER CURB MOUNTED | HVAC AIR INTAKE HOOD | |
| 320 | HVAC | EF-15 | EXHAUST FAN DIRECT DRIVE CENTRIFUGAL DOWNBLAST CURB MOUNTED | GREENHECK | GW-09-D-X | DATA PLATE NOT LEGIBLE | 4' DIA 20,000 CFM | HIGH ROOF MOUNTED ABOVE ROOM 110 NORTH EAST CORNER CURB MOUNTED | HVAC AIR INTAKE HOOD | |
| 320 | HVAC | EF-16 | EXHAUST FAN DIRECT DRIVE CENTRIFUGAL DOWNBLAST CURB MOUNTED | GREENHECK | GW-09-D-X | DATA PLATE NOT LEGIBLE | 4' DIA 20,000 CFM | HIGH ROOF MOUNTED ABOVE ROOM 110 SOUTH WEST CORNER CURB MOUNTED | HVAC AIR INTAKE HOOD | |
| 320 | HVAC | EF-17 | EXHAUST FAN DIRECT DRIVE CENTRIFUGAL DOWNBLAST CURB MOUNTED | GREENHECK | GW-09-D-X | DATA PLATE NOT LEGIBLE | 4' DIA 20,000 CFM | HIGH ROOF MOUNTED ABOVE ROOM 110 NORTH EAST CORNER CURB MOUNTED | HVAC AIR INTAKE HOOD | |
| 320 | HVAC | SF-1 EF-18 | SUPPLY FAN BELT DRIVE WALL AXIAL PROPELLER FAN | GREENHECK | SF1-12-426-D | 97EO7181 | .25 HP 12" DIA 585-1636 CFM 115 V | RISER ROOM 100 NORTH EAST CORNER 84" AFF WALL MOUNTED | T-STAT CONTROLLED | |
| 320 | HVAC | OADMP-1 | OUTSIDE AIR DAMPERS | SIEBE | MA220 | 9712 | 16" X 12" 14 WATT | RISER ROOM 100 SOUTH WEST CORNER 24" AFF | ||
| 320 | PLUMBING | BFP-1 | BACKFLOW PREVENTER | WATTS | 1960 | 007M1QT | 09461 | 1.5" | NORTH END EAST SIDE UNDER COVER EXTERIOR | |
| 320 | PLUMBING | BFP-2 | BACKFLOW PREVENTER | WATTS | 007M1QT | 13761 | 2" | ROOM 119 WEST WALL BY FIREMAIN RISER | ||
| 320 | PLUMBING | WF-1 | WATER FOUNTAIN | HALSEY TAYLOR | 2020 | HAC-HB-1B | 180926507 | 1/5 HP R-134A 115 VOLTS | OUTSIDE MENS ROOM 110 IN MAIN WAREHOUSE | WATER FILTER SENTRY PLUS # 55898C |
| 320 | PLUMBING | WHE-1 | WATER HEATER ELECTRIC | STATE WATER HEATER | 2020 | EN6-40-DORS-110 | 2012118721269 | 40 GAL 9000 WATTS | ROOM 104A MENS ROOM SOUTH WEST CORNER | |
| 320 | PLUMBING | WHE-2 | WATER HEATER ELECTRIC | STATE WATER HEATER | 2020 | EN6-40-DORS-110 | 1943116341656 | 40 GAL 9000 WATTS | ROOM 116 WOMENS ROOM NORTH EAST CORNER | |
| 320 | PLUMBING | EWS/D-1 | EYEWASH & DELUGE SHOWER STATION | GUARDIAN | NO DATA PLATE | 12" BOWL 10" SHOWER | NORTH EAST CORNER ROOM 116 | OFFLINE TAGGED OUT | ||
| 320 | PLUMBING | EWS -2 | EYEWASH & DELUGE SHOWER STATION | GUARDIAN | NO DATA PLATE | 12" BOWL 10" SHOWER | SOUTH EAST CORNER ROOM 110 |
| 322 | HVAC | PTAC-1 | PACKAGE TERMINAL AIR CONDITIONING UNIT HP | GOODMAN | 1997 | PTH123G35AXXXCA | 1711441624 | 2 TON R410A | LOCATED IN MAIN OFFICE EAST WALL 72" AFF | WASHABLE FILTER |
| 322 | HVAC | MSACU-1 | MINI-SPLIT AIR CONDENSER UNIT HP | COMFORT-AIRE | B-SMH24SC | C1357500411523130155 | 2 TON R410A | LOCATED ON PAD EAST SIDE EXTERIOR OF BLDG. NORTH END | ||
| 322 | HVAC | MSAHU-1 | MINI SPLIT AIR HANDLING UNIT | COMFORT-AIRE | A-SMH24SC | C1357500411523130166 | 2 TON R410A 208/230 | LOCATED IN BREAK ROOM EAST WALL NORTH END | WASHABLE FILTER | |
| 322 | HVAC | UHE-1 | UNIT HEATER ELECTRIC | TRANE | UHEC-153BACA | NONE | 15 KW | WEST WALL NORTH END MOUNTED IN OVERHEAD | T-STAT CONTROLLED | |
| 322 | HVAC | UHE-2 | UNIT HEATER ELECTRIC | DAYTON | 2023 | 2YU71 | NONE | 10 KW 3 PHASE 208 VOLTS 48 AMPS | WEST WALL SOUTH END MOUNTED IN OVERHEAD | T-STAT CONTROLLED |
| 322 | HVAC | EF-1 | EXHAUST FAN POWER ROOF VENTILATOR | GREENHECK | NO DATA PLATE | 18" DIA | LOCATED IN BREAK ROOM CENTER ROOF MOUNTED | |||
| 322 | HVAC | EF-2 | EXHAUST FAN BELT DRIVENAXIAL PROPELLER FAN WALL MOUNTED | GREENHECK | SBE-1E20-4 | 99H19179 | .25 HP 1800 RPM 3600 CFM 20" DIA | SOUTH WALL BETWEEN OVERHEAD DOORS | ||
| 322 | HVAC | EF-3 | EXHAUST FAN | PANASONIC | FV-11VQ3 | 704 | 8"DIA 96" AFF | LOCATED IN RESTROOM MOUNTED TO DROP CEILING | ||
| 322 | HVAC | OADMP-1 | OUTSIDE AIR DAMPERS | NO DATA PLATE | NO DATA PLATE | 36" X 36" | LOCATED ON NORTH WALL BETWEEN GARAGE DOORS | |||
| 322 | PLUMBING | EWS-1 | EYEWASH STATION | WATER SAVER | NO DATA PLATE | 12' BOWL | WEST WALL CENTER BY EXIT DOOR | |||
| 322 | PLUMBING | BFP-01 | BACKFLOW PREVENTER | WATTS | 007QT | 09896 | 1.5" | BREAK ROOM SOUTH EAST CORNER | ||
| 322 | PLUMBING | WHE-1 | WATER HEATER ELECTRIC | OA Smith | 2023 | E-6-40R45DV110 | 2320134138124 | 40 GALLON ELECTRIC | BREAK ROOM SOUTH EAST CORNER |
| 324 | ELECTRICAL | DTT-1 | DRY TYPE TRANSFORMER | DATA PLATE NOT LEGIBLE | DATA PLATE NOT LEGIBLE | DATA PLATE NOT LEGIBLE | ??? | ROOM 123 WALL MOUNTED AT ROOF LEVEL EAST WALL 14' AFF | ||
| 324 | HVAC | MSACU-1 | MINI-SPLIT AIR CONDENSER UNIT HP | MITSUBISHI ELECTRIC | 2015 | MXZ-3C24NA | 59U06160D | 2 TON R-410A | OUTSIDE SOUTH WALL WEST END PAD MOUNTED | MINI-SPLIT CONDENSER UNIT SPLIT 2 AHU's |
| 324 | HVAC | MSAHU-1-1 | MINI-SPLIT AIR HANDLING UNIT | MITSUBISHI ELECTRIC | 2015 | MSZ-GL12NA | 61E02853 | 1 TON R-410A | ROOM 114 SOUTH WALL 96" AFF | WASHABLE FILTER |
| 324 | HVAC | MSAHU-1-2 | MINI-SPLIT AIR HANDLING UNIT | MITSUBISHI ELECTRIC | 2015 | MSZ-GL12NA | 61E03590 | 1 TON R-410A | ROOM 114 SOUTH WALL 96" AFF | WASHABLE FILTER |
| 324 | HVAC | RTPCKU-1 | ROOF TOP PACKAGE UNIT HP | GOODMAN | 2016 | GPH1424M41AA | 1602100228 | 2 TON R-410A | HIGH ROOF MOUNTED SOUTH SIDE CENTER | FILTERS 24"X24"X2"=21 |
| 324 | HVAC | RTACU--2 | ROOF TOP AIR CONDENSER UNIT | GOODMAN | 2016 | GSZ140601KC | 1602270352 | 5 TON R-410 | LOWER ROOF MOUNTED SOUTH SIDE CENTER | |
| 324 | HVAC | AHU-2 | AIR HANDLING UNIT | GOODMAN | 2016 | ASPT161D14AA | 1510207588 | 5 TON R-410 | ROOM 105 WEST WALL CEILING MOUNTED 12' AFF | FILTER 20"X30"X1"=1 |
| 324 | HVAC | UHE-1 | UNIT HEATER ELECTRIC INFRARED | FOSTORIA | OCH-46 | DATA PLATE NOT LEGIBLE | 3000 KW | ROOM 102 WALL MOUNTED 84" AFF SOUTH WALL | T-STAT CONTROLLED | |
| 324 | HVAC | UHE-2 | UNIT HEATER ELECTRIC INFRARED | FOSTORIA | OCH-46 | DATA PLATE NOT LEGIBLE | 3000 KW | ROOM 102 WALL MOUNTED 84" AFF SOUTH WALL | T-STAT CONTROLLED | |
| 324 | HVAC | UHE-3 | UNIT HEATER ELECTRIC INFRARED | FOSTORIA | OCH-46 | DATA PLATE NOT LEGIBLE | 3000 KW | ROOM 102 WALL MOUNTED 84" AFF NORTH WALL | T-STAT CONTROLLED | |
| 324 | HVAC | UHE-4 | UNIT HEATER ELECTRIC INFRARED | FOSTORIA | OCH-46 | DATA PLATE NOT LEGIBLE | 3000 KW | ROOM 102 WALL MOUNTED 84" AFF NORTH WALL | T-STAT CONTROLLED | |
| 324 | HVAC | UHE-5 | UNIT HEATER ELECTRIC INFRARED | FOSTORIA | OCH-46 | DATA PLATE NOT LEGIBLE | 3000 KW | ROOM 103 WALL MOUNTED 84" AFF NORTH WALL | T-STAT CONTROLLED | |
| 324 | HVAC | UHE-6 | UNIT HEATER ELECTRIC INFRARED | FOSTORIA | OCH-46 | DATA PLATE NOT LEGIBLE | 3000 KW | ROOM 103 WALL MOUNTED 84" AFF NORTH WALL | T-STAT CONTROLLED | |
| 324 | HVAC | UHE-7 | UNIT HEATER ELECTRIC INFRARED | FOSTORIA | OCH-46 | DATA PLATE NOT LEGIBLE | 3000 KW | ROOM 103 WALL MOUNTED 84" AFF SOUTH WALL | T-STAT CONTROLLED | |
| 324 | HVAC | UHE-8 | UNIT HEATER ELECTRIC INFRARED | FOSTORIA | OCH-46 | DATA PLATE NOT LEGIBLE | 3000 KW | ROOM 103 WALL MOUNTED 84" AFF SOUTH WALL | T-STAT CONTROLLED | |
| 324 | HVAC | EF-1 | EXHAUST FAN BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | 1984 | GBE-10-4 | 538206 | .25 HP 300 CFM 10" DIA | ROOM 119 WOMENS ROOM LOWER ROOF WEST END | |
| 324 | HVAC | EF-2 | EXHAUST FAN CENTRIGUGAL DIRECT DRIVE | PENN BARRY | EST. 2008 | WCC08 | M08KZ90593 | 700 CFM DIA 8" | ROOM 118 MENS ROOM LOWER ROOF EAST END | |
| 324 | HVAC | EF-3 | EXHAUST FAN WALL MOUNTED PROPELLER | NO DATA PLATE | NO DATA PLATE | ROOM 114 NORTH WEST CORNER 96" AFF WALL MOUNTED | ||||
| 324 | PLUMBING | BFP-1 | BACKFLOW PREVENTER | WATTS | 007 | 09797 | 1.5" | SOUTH WALL EXTERIOR WALL MOUNTED 24" AFF | NON-INSULATED | |
| 324 | PLUMBING | EWS-1 | EYEWASH STATION | BRADLEY | NO DATA PLATE | 12" BOWL | ROOM 102 SOUTH WALL | |||
| 324 | PLUMBING | EWS-2 | EYEWASH STATION | BRADLEY | NO DATA PLATE | 12" BOWL | ROOM 103 SOUTH WALL | |||
| 324 | PLUMBING | WHE-1 | WATER HEATER ELECTRIC | WHIRLPOOL | E40R6-45110 | 16201030006239 | 40 GAL DUAL ELEMENT 9000 WATTS | ROOM 105 SOUTH WEST CORNER | ||
| 324 | PLUMBING | WF-1 | WATER FOUNTAIN | HALSEY TAYLOR | HAC-HB-1B | 1P0926490 | 1/5 HP R-134A 115 VOLTS | WALL MOUNTED | WATER FILTER SENTRY PLUS # 55898C | |
| 324 | SUMP PUMP | SP-7 | SUMP PUMP | LIBERTY PUMPS | 2021 | 257 | 13X8C9 | 1/3 HP 1 1/2" DISCHARGE 115 V | ROOM 105 NORTH WEST CORNER IN PIT |
| 326 | ELECTRICAL | DTT-1 | DRY TYPE TRANSFORMER | SQUARE D | EXN45T3HCU | 1020421291 | KVA 45 480/208/120 3 PHASE | ROOM 104 WEST WALL CENTER ON CURB | ||
| 326 | ELECTRICAL | DTT-2 | DRY TYPE TRANSFORMER | GENERAL ELECTRIC | 9T10A1001 | 1M0412126 | KVA 15 480/208/120 3 PHASE | ROOM 102 WEST WALL PAD MOUNTED | ||
| 326 | ELECTRICAL | DTT-3 | DRY TYPE TRANSFORMER | CHALLENGER | 152-415B-MOD-5 | J96G1280 | KVA 15 480/208/120 3 PHASE | ROOM 102 WEST WALL PAD MOUNTED | ||
| 326 | ELECTRICAL | DTT-4 | DRY TYPE TRANSFORMER | JEFFERSON ELECTRIC | 221-164 | 21866-1 | KVA 15 120/240/480 1 PHASE | ROOM 102 NORTH WALL WALL MOUNTED | ||
| 326 | HVAC | HP-1 ACU-1 | AIR CONDENSER UNIT HP | CARRIER | 2021 | 25HCE424A300 | 0921E20212 | 2 TON R-410-A | EAST END CENTER | |
| 326 | HVAC | AHU-1 | AIR HANDLING UNIT | CARRIER | 2021 | FV4CNF005 | 1021F10087 | 10 KW HEATER 1/2 HP | ROOM 104 CENTER CEILING MOUNTED | FILTER 20"X20"X1"=1 |
| 326 | HVAC | HP-2 ACU-2 | AIR CONDENSER UNIT HP | CARRIER | 2021 | 25HCE448A300 | 4920E21523 | 4 TON R-410-A | EAST END NORTH SIDE | |
| 326 | HVAC | AHU-2 | AIR HANDLING UNIT | CARRIER | 2021 | FV4CNF003 | 0721F30605 | 10 KW HEATER 1/2 HP | ROOM 104 EAST WALL CEILING MOUNTED | FILTER 20"X20"X1"=1 |
| 326 | HVAC | HP-3 ACU-3 | AIR CONDENSER UNIT HP | CARRIER | 2021 | 25HCE436A300 | 4420E12865 | 3 TON R-410-A | WEST END NORTH SIDE | |
| 326 | HVAC | AHU-3 | AIR HANDLING UNIT | CARRIER | 2021 | FV4CNF003 | 0721F30606 | 10 KW HEATER 1/2 HP | ROOM 101 MOUNTED ABOVE CEILING | FILTER 20"X20"X1"=1 |
| 326 | HVAC | HP-4 ACU-4 | AIR CONDENSER UNIT HP | CARRIER | 2021 | 25HCE436A300 | 4520E13105 | 3 TON R-410-A | WEST END SOUTH SIDE | |
| 326 | HVAC | AHU-4 | AIR HANDLING UNIT | CARRIER | 2021 | FV4CNF003 | 0721F30612 | 10 KW HEATER 1/2 HP | ROOM 101 MOUNTED ABOVE CEILING | FILTER 16"X20"X1"=1 |
| 326 | HVAC | UHE-11 | UNIT HEATER ELECTRIC | DIMPLEX | DGWHW031 | 708400100 | 4000 WATTS | ROOM 102 ABOVE DOOR SOUTH WALL | ||
| 326 | HVAC | EF-1 | EXHAUST FAN DIRECT DRIVE WALL AXIAL | JEN-AIR | COULD NOT ACCESS | 8" DIA | ROOM 110 SOUTH WALL WALL MOUNTED | |||
| 326 | HVAC | EF-2 | EXHAUST FAN DIRECT DRIVE WALL AXIAL | JEN-AIR | COULD NOT ACCESS | 8"DIA | ROOM 105 SOUTH WALL WALL MOUNTED | |||
| 326 | HVAC | EF-4 | EXHAUST FAN BELT DRIVE DOWNBLAST CENTRIFUGAL | GREENHECK | G-160-B-X | 96300073 | 1/2 HP 2013-3308 CFM 17" DIA | ROOM 109 CLASS ROOM ROOF MOUNTED | ABOVE DROP CEILING NOT USED | |
| 326 | HVAC | EF-6 | EXHAUST FAN | JEN-AIR | 70CWA | 108 | 8" DIA | ROOM 103 CLASS ROOM RESTROOM SOUTH WALL | ||
| 326 | PLUMBING | ET-1 | EXPANSION TANK | FLOTEC | FP7120-08 | 001M1OA | 8 GALLON | ROOM 109 CLASSROOM | ||
| 326 | PLUMBING | WF-1 | WATER FOUNTIAN | HALSEY TAYLOR | 2019 | HAC8FSCWSQ | 180929980 | 1/5 HP R-134A 115 VOLTS | ROOM 101 SOUTH WALL | WATER FILTER SENTRY PLUS # 55898C |
| 326 | PLUMBING | BFP-01 | BACKFLOW PREVENTER | WATTS | 009QTM1 | 33122 | 1.25" | EXTERIOR SOUTH SIDE UNDER COVER | ||
| 326 | PLUMBING | WHE-1 | WATER HEATER ELECTRIC | A.O. SMITH | 2021 | E6-40H45DV 110 | 2043121598609 | 40 GAL 4500 WATTS | ROOM 102 NORTH WALL |
| 328 | ELECTRICAL | DTT-1 | DRY TYPE TRANSFORMER | SQUARE D | 2019 | EX150T3HC4 | 2072716159A | 150 KVA 480/208/120 3 PHASE | ROOM 110 WEST WALL | |
| 328 | ELECTRICAL | DTT-2 | DRY TYPE TRANSFORMER | SQUARE D | 2017 | EX75T3H | 1011618247 | 75 KVA 480/208/120 3 PHASE | ROOM 100 WEST WALL HIGH BAY | |
| 328 | HVAC | RTPCKU-1 | ROOF TOP PACKAGE UNIT HP | CARRIER | 2017 | 50KCOA04A2AGAOAOAO | 4517C621647017 | 6 TON R-410A | LOWER ROOF EAST SIDE SOUTH END | FILTERS 16"X25"X2"=4 |
| 328 | HVAC | RTPCKU-2 | ROOF TOP PACKAGE UNIT HP | CARRIER | 2017 | 50TCQA07A2A6AOAOAO | 3617C5 | 6 TON R-410A | LOWER ROOF EAST SIDE NORTH END | FILTERS 16"X16"X2"=2 |
| 328 | HVAC | MSACU-1 | MINI-SPLIT AIR CONDENSER UNIT HP | MITSUBISHI ELECTRIC | 2017 | MUZ-GL09NA | 62C01903 | R-410A | EAST SIDE PAD MOUNTED SOUTH END | |
| 328 | HVAC | MSAHU-1 | MINI-SPLIT AIR HANDLING UNIT | MITSUBISHI ELECTRIC | 2017 | MSZ-GL09A | 7XE95346 | R-410A | ROOM 103 WEST WALL ABOVE DOOR | WASHABLE FILTER |
| 328 | HVAC | MAU-1 | MAKE-UP AIR UNIT NON-RECIRCULATING DIRECT INDUSTRIALAIR HEATER | RAPID ENGINEERING | 2017 | 2010 | 18-01-0104B | 5 HP 7000 CFM 393,120 MAX BTU | WEST WALL NORTH END EXTERIOR ON STAND | |
| 328 | HVAC | MAU-2 | MAKE-UP AIR UNIT NON-RECIRCULATING DIRECT INDUSTRIALAIR HEATER | RAPID ENGINEERING | 2017 | 2010 | 18-01-0104A | 5 HP 7000 CFM 393,120 MAX BTU | WEST WALL SOUTH END EXTERIOR ON STAND | |
| 328 | HVAC | EF-5 [PRV] | POWER ROOF VENTILATOR BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | 2017 | GB-540-75-X | 96B09515 | 8500 CFM 60"' DIA | ROOF MOUNTED HIGH BAY SOUTH WEST CORNER | TRANE LISTING (EF-5328) |
| 328 | HVAC | EF-6 [PRV] | POWER ROOF VENTILATOR BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | 2017 | GB-540-75-X | 96B09516 | 8500 CFM 60"' DIA | ROOF MOUNTED HIGH BAY NORTH WEST CORNER | TRANE LISTING (EF-6328) |
| 328 | HVAC | EF-7 [PRV] | POWER ROOF VENTILATOR BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | 2017 | GB-540-75-X | 96B09517 | 8500 CFM 60"' DIA | ROOF MOUNTED HIGH BAY SOUTH EAST CORNER | TRANE LISTING (EF-7328) |
| 328 | HVAC | EF-8 [PRV] | POWER ROOF VENTILATOR BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | 2017 | GB-540-75-X | 96B009518 | 8500 CFM 60"' DIA | ROOF MOUNTED HIGH BAY NORTH EAST CORNER | TRANE LISTING (EF-8328) |
| 328 | HVAC | EF-9 | EXHAUST FAN BELT DRIVE DOWN BLAST CENTRIFUGAL | GREENHECK | 2017 | GB-160-4 | 15446707 18E | 1/2 HP 2013-3308 CFM 17" DIA | LOWER ROOF ABOVE ROOM 107 WOMENS RESTROOM | |
| 328 | HVAC | EF-10 | EXHAUST FAN SPUN GRAVITY VENTILATOR | GREENHECK | 2018 | GRSR-12 | 15446705 | LOWER ROOF ABOVE ROOM 110 NORTH EAST CORNER | ||
| 328 | HVAC | OADMP-1 | OUTSIDE AIR DAMPERS | RUSKIN ACTUATOR | 2017 | RUS-L24-MOD | 21RY1181045841 | 60" X 90" | ROOM 100 SOUTH EAST CORNER WALL MOUNTED | |
| 328 | HVAC | OADMP-2 | OUTSIDE AIR DAMPERS | RUSKIN ACTUATOR | 2017 | RUS-L24-MOD | 21RY1181045841 | 60" X 90" | ROOM 100 SOUTH EAST CORNER WALL MOUNTED | |
| 328 | HVAC | OADMP-3 | OUTSIDE AIR DAMPERS | RUSKIN ACTUATOR | 2017 | RUS-L24-MOD | 21RY1181045841 | 60" X 90" | ROOM 100 NORTH WEST CORNER WALL MOUNTED | |
| 328 | HVAC | OADMP-4 | OUTSIDE AIR DAMPERS | RUSKIN ACTUATOR | 2017 | RUS-L24-MOD | 21RY1181045841 | 60" X 90" | ROOM 100 NORTH WEST CORNER WALL MOUNTED | |
| 328 | PLUMBING | BFP-1 | BACKFLOW PREVENTER | WATTS | 2017 | LF007M2QT | 009612 | 1.5" | OUTSIDE MECHANICAL ROOM EAST SIDE | |
| 328 | PLUMBING | WF-1 | WATER FOUNTAIN | ELKAY | 2017 | LZSWSLP | 180537490 | R-134A | ROOM 101 NORTH END OF HALLWAY | FILTERED ??? |
| 328 | PLUMBING | WHE-1 | WATER HEATER ELECTRIC | OA SMITH | 2017 | DEN-80-110 | 1812109738613 | 80 GALLON | CLOSET IN HALLWAY BY ROOM 107 | |
| 328 | PLUMBING | WHE-2 | WATER HEATER ELECTRIC | OA SMITH | 2017 | DEN-80-110 | 1812109757103 | 80 GALLON | ROOM 111 NORTH WEST CORNER | |
| 328 | PLUMBING | EWS/D-1 | EYEWASH & DELUGE SHOWER STATION | BRADLEY | 2017 | S19314EW | NONE | 12" BOWL 10" SHOWER | ROOM 100 SOUTH END | |
| 328 | PLUMBING | EWS/D-1 | EYEWASH & DELUGE SHOWER STATION | BRADLEY | 2017 | S19314EW | NONE | 12" BOWL 10" SHOWER | ROOM 100 SOUTH END | |
| 328 | PLUMBING | MV-1 | THERMOSTATIC MIXING VALVE | BRADLEY 'NAVIGATOR | 2017 | 319-2100 | S19314EW | 3/4 NPT 65-95 F | ROOM 100 SOUTH END BEHIND EYEWASH STATION | |
| 328 | PLUMBING | MV-2 | THERMOSTATIC MIXING VALVE | BRADLEY 'NAVIGATOR | 2017 | 319-2100 | S19314EW | 3/4 NPT 65-95 F | ROOM 100 SOUTH END BEHIND EYEWASH STATION |
| 335 | ELECTRICAL | DTT-1 | DRY TYPE TRANSFORMER | SQUARE D | EX150T3HCU | 2072216142A | 150 KVA 480V 3 PHASE | ROOM 107 NORTH END CENTER |
| 335 | HVAC | MAU-1 | MAKE-UP AIR UNIT DIRECT FIRED GAS HEATER | INDUSTRIAL |
COMMERCIAL
| EQUIPMENT | 2000 | BMR-120-VTR | 029645550 | MBH GAS | EAST WALL EXTERIOR OUTSIDE ROOM 109 ON STAND |
| 335 | HVAC | MAU-2 | MAKE-UP AIR UNIT DIRECT FIRED GAS HEATER | INDUSTRIAL |
COMMERCIAL
| EQUIPMENT | 1996 | BMR-130-VTRB3 | 029643330 | MBH GAS | WEST WALL EXTERIOR NORTH END ON STAND | ||||||
| 335 | HVAC | MSACU-1 | MINI-SPLIT AIR CONDENSER UNIT HP | COMFORT-AIRE | 2012 | A-SMH245C-1 | DKGV00109 | 2 TON R-410A | WEST WALL EXTERIOR | ||
| 335 | HVAC | MSAHU-1 | MINI-SPLIT AIR HANDLING UNIT | COMFORT-AIRE | 2012 | B-SMH24SC-1 | C12971000-1307130049 | 23,000 BTU | ROOM 104 WEST WALL | WASHABLE FILTER | |
| 335 | HVAC | ACU-1 | AIR CONDENSER UNIT HP | TRANE | 2002 | TWA120A400EA | 2175LBLAD | 10 TON | PAD SOUTH EAST CORNER | ||
| 335 | HVAC | AHU-1 | AIR HANDELING UNIT | TRANE | 2002 | TWE120A300EA | 20824KE5H | 10 TON 15 KW R-22 | ROOM 122 SOUTH EAST CORNER | FILTERS 16"X25"X1"=4 | |
| 335 | HVAC | EF-5 | EXHAUST FAN BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | GB-420-75-X | 96B10970 | 7.5 HP 42" DIA 23,000 CFM | HIGH ROOF CENTER LINE SOUTH END | |||
| 335 | HVAC | EF-6 | EXHAUST FAN BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | GB-420-75-X | 96B10971 | 7.5 HP 42" DIA 23,000 CFM | HIGH ROOF CENTER LINE CENTER | |||
| 335 | HVAC | EF-7 | EXHAUST FAN BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | GB-420-75-X | 96B10972 | 7.5 HP 42" DIA 23,000 CFM | HIGH ROOF CENTER LINE NORTH END | |||
| 335 | HVAC | EF-8 | EXHAUST FAN BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | GB-360-50-X | 96B09022 | 13,000 CFM | MEDIUM ROOF ABOVE ROOM 109 CENTER | |||
| 335 | HVAC | EF-9 | EXHAUST FAN DIRECT DRIVE WALL AXIAL PROPELLER FAN | GREENHECK | SEI-12-432-E-X | 96B09357 | .25 HP 1050 RPM 12" DIA 586-1636 CFM | ROOM 108 EAST WALL 74" AFF WALL MOUNTED | |||
| 335 | HVAC | EF-10 EF-10335 | EXHAUST FAN DIRECT DRIVE WALL AXIAL PROPELLER FAN | GREENHECK | SEI-12-432-E-X | 96B09358 | .25 HP 1050 RPM 12" DIA 586-1636 CFM | ROOM 110 EAST WALL 74" AFF WALL MOUNTED | |||
| 335 | HVAC | EF-11 | EXHAUST FAN BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | 2000 | CUBE-240 | 330561 | 13.5" DIA 1000 CFM | LOWER ROOF SOUTH SIDE ABOVE ROOM 118 | ||
| 335 | HVAC | EF-12 | EXHAUST FAN BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | 2000 | CUBE-240 | 492127 | 18" DIA 1000 CFM | LOWER ROOF ABOVE ROOM ROOM 124 | ||
| 335 | HVAC | EF-14 | EXHAUST FAN | JENN AIRE | DATA PLATE NOT LEGIBLE | 36" DIA | LOWER ROOF ABOVE ROOM 107 CENTER | ||||
| 335 | HVAC | EF-16 | EXHAUST FAN BELT DRIVE DOWN BLAST CENTRIFUGAL CURB MOUNTED | GREENHECK | DATA PLATE NOT LEGIBLE | 12" DIA | LOWER ROOF EAST SIDE ABOVE ROOM 116 | ||||
| 335 | PLUMBING | BFP 1 | BACKFLOW PREVENTER | WILKENS | 2023 | 350ASTR | 41664 | 3" | ROOM 108 SOUTH WALL CENTER 36" AFF | ||
| 335 | PLUMBING | WF-1 | WATER FOUNTAIN | ELKAY | FD7003 1E | 030614416 | ROOM 112 SOUTH EAST CORNER SUPERVISORS OFFICE FLOOR MOUNTED | NON FILTERED | |||
| 335 | PLUMBING | WF-2 | WATER FOUNTAIN | HALSEY TAYLOR | 2020 | HAC-HB-1B | 180926501 | 1/5 HP R-134A 115 VOLTS | ROOM 117 SOUTH WALL BREAK ROOM WALL MOUNTED | WATER FILTER SENTRY PLUS # 55898C | |
| 335 | PLUMBING | WHE-1 | WATER HEATER ELECTRIC | JACKSON | CO5233 | C23733 | 52 GAL ELECTRIC | ROOM 115 NORTH EAST CORNER OF HALLWAY | |||
| 335 | PLUMBING | WHE-2 | WATER HEATER ELECTRIC | RUDD | 1990 | PE52-2 | 0491813847 | 50 GAL ELECTRIC | ROOM 107 SOUTH WEST CORNER | ||
| 335 | PLUMBING | EWS-1 | EYEWASH STATION | BRADLEY | NO DATA PLATE | 12" BOWL | ROOM 109 SOUTH WEST CORNER | ||||
| 335 | PLUMBING | EWS-2 | EYEWASH STATION | BRADLEY | NO DATA PLATE | 12" BOWL | ROOM 101 EAST WALL OUTSIDE MENS ROOM |
| 344 | ELECTRICAL | SWGR | SWGR 480Y/277V 3 PHASE 4 WIRE | GENERAL ELECTRIC | DR-SWBD62221 | NONE | 1000 AMPS | ROOM 107 CENTER | ||
| 344 | ELECTRICAL | DTT-2 | DRY TYPE TRANSFORMER | SQUARE D | EX112T3HCU | 2082316139A | 112.5 KVA | ROOM 107 WEST END | ||
| 344 | ELECTRICAL | DTT-3 | DRY TYPE TRANSFORMER | GENERAL ELECTRIC | 9T23 B 3872 | FN | 30 KVA 480-208Y/120V | ROOM 118 MECHANICAL | ||
| 344 | ELECTRICAL | DTT-4 | DRY TYPE TRANSFORMER | GENERAL ELECTRIC | E-687447 | NONE | 500 KVA | ROOM 107 WEST END | ||
| 344 | HVAC | PTAC-1 | PACKAGE TERMINAL AIR CONDITIONING UNIT HP | AMANA | PTH123B25AMBP | 0805676252 | 1 TON R-22 10,800 HEAT | ROOM 110A EAST WALL 18" AFF SERVER ROOM | WASHABLE FILTER | |
| 344 | HVAC | ACU-1 | AIR CONDENSER UNIT | AAON COIL PRODUCTS | 2017 | CFA-009-B-A-3-DCOOK | 201703-CNCG02493 | 9 TON 460 VAC 3 PHASE | EAST WALL NORTH END | |
| 344 | HVAC | AHU-1 | AIR HANDLING UNIT | AAON COIL PRODUCTS | 2017 | H3-CRB-3-0-142D-3B2 | 201703-CJEC03696 | 9 TON 460 VAC 3 PHASE | 2ND FLOOR CATWALK EAST WALL | FILTERS 16"X20"X2"=4 |
| 344 | HVAC | ACU-2 | AIR CONDENSER UNIT | AAON COIL PRODUCTS | 2017 | CFA-009-B-A-3-DCOOK | 201703-CNCG02494 | 9 TON 460 VAC 3 PHASE | SOUTH WEST CORNER EXTERIOR | |
| 344 | HVAC | AHU-2 | AIR HANDLING UNIT | AAON COIL PRODUCTS | 2017 | V3-CRE-3-0-142D-3A1 | 201703-CJEC03697 | 9 TON 460 VAC 3 PHASE | ROOM 118 NORTH SIDE | FILTERS 20"X20"X2"=2 16"X20"X2"=1 |
| 344 | HVAC | VAV-1 | VARIABLE AIR VOLUME BOX | JCI | TSSEH | 6CEM009489 | .5 HP 1.5 KW ELECRTIC HEAT | 2ND FLOOR CATWALK CENTER | FILTER ??? | |
| 344 | HVAC | VAV-2 | VARIABLE AIR VOLUME BOX | JCI | TSSEH | 6CEM009496 | .5 HP 1.5 KW ELECRTIC HEAT | 2ND FLOOR CATWALK CENTER | FILTER ??? | |
| 344 | HVAC | VAV-110-8 | VARIABLE AIR VOLUME BOX | JCI | TSSEH | 6CEM009491 | .5 HP 1.5 KW ELECRTIC HEAT | ROOM 110 CEILING MOUNTED SOUTH SIDE | FILTER ??? | |
| 344 | HVAC | VAV-111-9 | VARIABLE AIR VOLUME BOX | JCI | TSSEH | 6CEM009492 | .5 HP 1.5 KW ELECRTIC HEAT | ROOM 112 CEILING MOUNTED EAST WALL CENTER | FILTER ??? | |
| 344 | HVAC | VAV-113-10 | VARIABLE AIR VOLUME BOX | JCI | TSSEH | 6CEM009494 | .5 HP 1.5 KW ELECRTIC HEAT | ROOM 113 CEILING MOUNTED EAST WALL SOUTH END | FILTER ??? | |
| 344 | HVAC | VAV-114-11 | VARIABLE AIR VOLUME BOX | JCI | TSSEH | 6CEM009493 | .5 HP 1.5 KW ELECRTIC HEAT | ROOM 114 CEILING MOUNTED NORTH EAST CORNER | FILTER ??? | |
| 344 | HVAC | VAV-HALL-12 | VARIABLE AIR VOLUME BOX | JCI | TSSEH | 6CEM009495 | .5 HP 1.5 KW ELECRTIC HEAT | CORRIDOR CEILING MOUNTED SOUTH SIDE CENTER | FILTER ??? | |
| 344 | HVAC | EF-3 | EXHAUST FAN BELT DRIVE SQUARE INLINE CENTRIFUGAL DUCT MOUNTED | BREIDERT | 2008 | SQD060G | 84302 | 350 RPM 115 WATTS | ROOM 107 NORTH END BEHIND OFFICE AREA CEILING MOUNTED | |
| 344 | HVAC | EF-4 | EXHAUST FAN BELT DRIVE SQUARE CENTRIFUGAL INLINE DUCT FAN | GREENHECK | SQB062508DP | 84303 | .5 HP 1808 CFM | ROOM 107 SOUTH END BEHIND OFFICE AREA CEILING MOUNTED | ||
| 344 | HVAC | EF-5 | EXHAUST FAN DIRECT DRIVE SQUARE CENTRIFUGAL FAN | BREIDERT | COULD NOT ACCESS THROUGH SHEETROCK CEILING | ROOM 117 | ||||
| 344 | HVAC | EF-6 | EXHAUST FAN DIRECT DRIVE SQUARE CENTRIFUGAL FAN | BREIDERT | COULD NOT ACCESS THROUGH SHEETROCK CEILING | ROOM 115 MENS ROOM | ||||
| 344 | HVAC | EF-7 | EXHAUST FAN DIRECT DRIVE SQUARE CENTRIFUGAL FAN | BREIDERT | COULD NOT ACCESS THROUGH SHEETROCK CEILING | ROOM 115A WOMENS ROOM | ||||
| 344 | HVAC | EF-8 | EXHAUST FAN ROUND CENTRIFUGAL DIRECT DRIVE INLINE DUCT FAN | FAN TECH | FG10XL 40411 | 1002880225 | ROOM 116 CORRIDOR WEST END ABOVE CEILING | |||
| 344 | HVAC | EF-9 | EXHAUST FAN SPUN ALUMINUM GRAVITY VENTILATOR CURB MOUNTED | GREENHECK | GRS-16-QD | 15164708 | 29" DIA | ROOM 118 SOUTH WEST CORNER | ||
| 344 | HVAC | DHR-1 | DEHUMIDIFIER | DESERT AIRE | HPR1202NNCNHN | 2017024909 | R 410A 115-1-60 | ROOM 101 NORTH WALL CENTER | ||
| 344 | HVAC | DHR-2 | DEHUMIDIFIER | DESERT AIRE | HPR1202NNCNHN | 2017024910 | R 410A 115-1-60 | ROOM 106 SOUTH WALL WEST END | ||
| 344 | PLUMBING | BFP-02 | BACKFLOW PREVENTER | WATTS | 007M1 | 14025 | 2" | ROOM 118 SOUTH EAST CORNER 24" AFF | ||
| 344 | PLUMBING | SP-1 | SUMP PUMP | LIBERTY PUMPS | 2023 | LE51A | 15YZLO | .5 HP 115 V 1 PHASE 2' DISCHARGE 30' MAX HD | ROOM 107 IN PIT NORTH SIDE OF SWITCH GEAR | |
| 344 | PLUMBING | WF-1 | WATER FOUNTIAN | HALSEY TAYLOR | 2020 | HAC-HB-1B | 180926199 | 1/5 HP R-134A 115 VOLTS | ROOM 116 SOUTH END BY RESTROOMS | WATER FILTER SENTRY PLUS # 55898C |
| 344 | PLUMBING | WHE-1 | WATER HEATER ELECTRIC | RHEEM | 81V52D | RH 0698B38435 | 50 GALLON 4500 WATTS | ROOM 118 SOUTH EAST CORNER |
| 346 | ELECTRICAL | DTT-1 | DRY TYPE TRANSFORMER | SEMENS | 2017 | 3F3Y045B | QL | 45 KVA 480-208Y/120V | ROOM 203 2ND FLOOR WEST WALL | |
| 346 | ELECTRICAL | DTT-2 | DRY TYPE TRANSFORMER | GENERAL ELECTRIC | 9T23A3872-G12 | NONE | 30 KVA 480-208Y/120V | ROOM 106 EAST WALL 48" AFF | ||
| 346 | ELECTRICAL | DTT-3 | DRY TYPE TRANSFORMER | SORGEL | 15T3HF | 100857-13 | 15 KVA 480-208Y/120V | ROOM 107 SOUTH WEST CORNER | ||
| 346 | ELECTRICAL | DTT-4 | DRY TYPE TRANSFORMER | SQUARE D | 2018 | 15T3HF | NONE | 15 KVA 480-208Y/120V | ROOM M110 2ND FLOOR MEZZAINE WEST WALL CENTER | |
| 346 | HVAC | ACU-1 | AIR CONDENSER UNIT | TRANE | 2016 | TWA120D40RBA | 16045PTHYA | 10 TON R-410A | LOWER ROOF ABOVE ROOM 107 | |
| 346 | HVAC | AHU-1 | AIR HANDLING UNIT | TRANE | 2016 | CSAA008UAL00 | K16C20129 | 7.5 TON R-410A | ROOM 201 2ND FLOOR CENTER | FILTERS 20"X35"X2"=2 |
| 346 | HVAC | UHE-4 | UNIT HEATER ELECTRIC | TASK MASTER | PEP5105CAIN | DATA PLATE NOT LEGIBLE | 5 KW | RISER ROOM EXTERIOR NORTH WEST CORNER 74" AFF | ||
| 346 | HVAC | EF-1 | EXHAUST FAN DIRECT DRIVE SIDEWALL MOUNTED PROPELLER | GREENHECK | 2008 | SE1-14-440-C8 | DATA PLATE NOT LEGIBLE | 1/3 HP 860 RPM 2734 CFM 14" DIA | ROOM 105 SOUTH WALL BASE OF OVERHEAD DOOR WEST SIDE | |
| 346 | HVAC | EF-2 | EXHAUST FAN DIRECT DRIVE SIDEWALL MOUNTED PROPELLER | GREENHECK | 2008 | SE1-14-440-C8 | 96C07986 | 1/3 HP 860 RPM 2734 CFM 14" DIA | ROOM 104 SOUTH WALL BASE OF OVERHEAD DOOR WEST SIDE | |
| 346 | HVAC | EF-3 | EXHAUST FAN DIRECT DRIVE SIDEWALL MOUNTED PROPELLER | GREENHECK | 2008 | SE1-14-440-C8 | 96C07587 | 1/3 HP 860 RPM 2734 CFM 14" DIA | ROOM 103 SOUTH WALL BASE OF OVERHEAD DOOR WEST SIDE | |
| 346 | HVAC | EF-4 | EXHAUST FAN DIRECT DRIVE SIDEWALL MOUNTED PROPELLER | GREENHECK | 2008 | SE1-14-440-C8 | 96C07588 | 1/3 HP 860 RPM 2734 CFM 14" DIA | ROOM 102 SOUTH WALL BASE OF OVERHEAD DOOR WEST SIDE | |
| 346 | HVAC | EF-5 | EXHAUST FAN DIRECT DRIVE SIDEWALL MOUNTED PROPELLER | GREENHECK | 2008 | SE1-14-440-C8 | 96C07589 | 1/3 HP 860 RPM 2734 CFM 14" DIA | ROOM 101 SOUTH WALL BASE OF OVERHEAD DOOR WEST SIDE | |
| 346 | HVAC | EF-6 | EXHAUST FAN DIRECT DRIVE SIDEWALL MOUNTED PROPELLER | GREENHECK | 2023 | SE1-14-440-C8 | 96C07560 | 1/3 HP 860 RPM 2734 CFM 14" DIA | ROOM 105 ABOVE OVERHEAD DOOR 15' AFF | MOTOR MODEL YD56C11G5303HJ HP1/4 115 V RPM 1140 FR. 56 TYPE SCSE 5.4 AMPS DUTY CONT 40 CAMB S.F. 1 CODE K |
| 346 | HVAC | EF-7 | EXHAUST FAN DIRECT DRIVE SIDEWALL MOUNTED PROPELLER | GREENHECK | 2008 | SE1-14-440-C8 | DATA PLATE NOT LEGIBLE | 1/3 HP 860 RPM 2734 CFM 14" DIA | ROOM 104 ABOVE OVERHEAD DOOR 15' AFF | |
| 346 | HVAC | EF-8 | EXHAUST FAN DIRECT DRIVE SIDEWALL MOUNTED PROPELLER | GREENHECK | 2023 | SE1-14-440-C8 | 96C07593 | 1/3 HP 860 RPM 2734 CFM 14" DIA | ROOM 103 ABOVE OVERHEAD DOOR 15' AFF | MOTOR MODEL YD56C11G5303HJ HP1/4 115 V RPM 1140 FR. 56 TYPE SCSE 5.4 AMPS DUTY CONT 40 CAMB S.F. 1 CODE K |
| 346 | HVAC | EF-9 | EXHAUST FAN DIRECT DRIVE SIDEWALL MOUNTED PROPELLER | GREENHECK | 2008 | SE1-14-440-C8 | 96C07592 | 1/3 HP 860 RPM 2734 CFM 14" DIA | ROOM 102 ABOVE OVERHEAD DOOR 15' AFF |
This is the start of the file's text. The full file is on GovTribe.