Appendix L - LAMS Maintenance Requirements.pdf

PDF 651 KB Posted

Attached to
Army Field Support Battalion (AFSBn-CHS) Facility Preventive Maintenance, Inspection & Repair Services
Solicitation number
FA441824Q0001
Issued by

About this file

This document contains an appendix outlining maintenance requirements for shelters and a related federal contract opportunity. The appendix provides inspection checklists and maintenance procedures for shelter components including baseplates, roll-up doors, personnel doors, fabric panels, electrical systems, and optional systems. Inspections are recommended at various frequencies from monthly to every six months. The procedures focus on identifying damage, wear, and safety concerns before addressing corrective actions.

The related federal contract opportunity is a solicitation from the Department of the Air Force Air Mobility Command to provide preventative maintenance, inspection, and repair services for Army Field Support Battalion facilities. The solicitation seeks maintenance of shelters and other structures to support readiness. Details on response dates, pricing terms, or incumbent are not provided.

View the file

Other files

File Type Posted
PWS AFSBn - CHS (Revision 11 Jan 2024).pdf PDF
Site Visit Attendees.pdf PDF
Q and A_FA441824Q0001.pdf PDF
AFSBn-CHS V2 Map.pdf PDF
Wage Determination_CBA-2023-746.pdf PDF
Appendix A - Equipment Inventory_Real Property_19 Dec 23.xlsx XLSX spreadsheet
Joint Base Charleston Base Access Worksheet - Form 111 (Aug 22).pdf PDF
COMBO_AFSBn_FA441824Q0001.pdf PDF
Appendix D- Service Call Historical Workload Data 2023 - Non-Real Property.xlsx XLSX spreadsheet
Appendix H - Wash Rack Service Matrix_2023.xlsx XLSX spreadsheet
Appendix A - Equipment Inventory_Real Property_26 Oct 2018.xlsx XLSX spreadsheet
Appendix M - Engineering Technical Advisory_Legionellos Mitigation Actions.pdf PDF
AFSBn Facility Maintenance and Repair Services Bid Schedule.xlsx XLSX spreadsheet
Appendix E - Building Inventory.xlsx XLSX spreadsheet
Provisions and Clauses.pdf PDF
Appendix F - Boilers (2022).xlsx XLSX spreadsheet
Appendix G - Wash Rack Parts List 2023.xlsx XLSX spreadsheet
Appendix I - Points of Demarcation.pdf PDF
Appendix J - Contractor Base Security and Access.pdf PDF
PWS AFSBn-CHS (Revision 23 August 2023).pdf PDF
Appendix C- Service Call Historical Workload Data 2023 - Real Property.xlsx XLSX spreadsheet
Wage Determination 2015-4427 Rev 24 dated 10 July 2023.pdf PDF
Appendix B - Equipment Inventory NON Real Property (New) Oct 2023.xlsx XLSX spreadsheet
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CHAPTER 13

Shelter Maintenance

13 3 P . d' M . t eno IC am enance ec IS . UIC re erence gu1 e or s e er inspec 10n Ch kl' t Q . k f 'd f h It f

Item to be Inspection Inspection Checked Procedure/Condition Suggested Corrective Action Frequency

Baseplate Baseplate is cracked or Replace all damaged parts. Do 6 Months broken. not weld or repair parts.

Check all attaching parts, Tighten components to secure. 6 Months pins, nuts and bolts. Replace damaged parts promptlv.

Anchor System Inspect brackets and bolts Replace as required. 6 Months for damaqe.

Inspect truck straps for Replace as required. 6 Months abnormal wear/fraying.

Truck straps. Replace every 2 years. 6 Months

Shear Cables Inspect and check all cables Replace all missing or broken 6 Months for safe operation. components promptly.

Check for incorrect cable Replace worn or frayed cables. 6 Months tension due to damaged (Use approved lifting device.)

wires.

Check for missing, loose or Reinstall missing hardware and 6 Months damaqed connections. reattach loose connectors.

Check wires and clamps for Hand tighten turnbuckle until 6 Months proper cable tension. cable is iust taut and not tight.

Roll-Up Doors Door curtain drags in one or Adjust guide rail clips and 6 Months both quide rail tracks. lubricate rails with qrease.

Door is out of plumb and will Relocate drum using slotted 6 Months not align correctlv. bracket and readjust with level.

Door curtain lowers easily Adjust for more spring tension 6 Months and raises hard. and lubricate contactinq parts.

Door curtain has side play. Adjust guide rail tracks and 6 Months tighten all rail clips. Refer to OEM instructions.

Personnel Doors Door drags when opening. Check hinges and seals. 6 Months Lubricate with silicone type spray.

Door will not close easily. Align striker plate. Lubricate 6 Months Latchinq parts stick. hinqes and latchinq mechanism.

Lock tumblers stick and key Lubricate lock mechanism with 6 Months will not turn. silicone spray or graphite.

Door return speed is not Adjust closing speed controls. 6 Months correct. Return resistance Adjust by rotating adjustment and closing power control is nut. See Door Controls Specs.

incorrect.

Latch cannot release the Adjust and lubricate parts. See 6 Months door. OEM instructions.

13.2

0 Action K Required

10/01/08

Appendix L - LAMS Maintenance Requirements

Shelter Maintenance

13 3 P . d" M . t eno IC am enance ec IS . UIC re erence !=!LIi e ors e ter 1nspec 10n Ch kl" t Q . k f "d f h I r

Bay Arches Straight wall or curve beam is Order replacement components, 6 Months & bent or cracked. replace wall or beam, and re-erec after major affected bays. storms

Fabric Panels

Beam connector is damaged c Order replacement components 6 Months missing hardware. and reinstall to secure structure.

Visually inspect all fabric pane Repair with panels in place. Use and welded material seams. Fabric Repair Kit (optional). 6 months

Check condition of fabric pam Patch small tear or puncture and inside and out for damage. repair large rip or hole. 6 months

Fabric is soiled with dirt, mud 1 Clean with mild soap and water qrease. (inside and outside). 6 months Inspect Clamclips and materic: Reinstall loose Clamclips and tension at C-groove locations. Clamlocks as required. 6 months

Inspect welded fabric seam Repair and patch as required.

connections and any zippers. Replace severely damaged pane 6 months

Check manually operated See Owner's Manual. Replace winch. (Used to install fabric inoperative unit.

Prior to use panels.)

Electrical Systems Main input electrical power Consult qualified personnel for Annual distribution panel inspection. testing and repairs.

Check panel for tripped or Reset to on; replace defective Annual switched off breakers. breakers, switches or fuses.

Test electrical status of power Check for correct installation and Annual receptacles. proper wire connections.

Check lamp illumination, Replace expired lamps, do not Annual connection at twistlock outlet scratch or touch high-pressure and circuit breaker switch.

Test operational status of ON/OFF power switches.

sodium bulbs with bare hands.

Watch for electric sparks. Carree Annual hazardous conditions.

Set circuit breaker to ON, AC Check all cable connections. Monthly overhead lights should Replace expired AC lamp.

illuminate.

Set circuit breaker to OFF, DC Check for possible shorts in wirin Monthly lights at Exits should illuminat1 Replace expired DC lamps.

10/01/08 13.3

Shelter Maintenance

13.3 P . d' M . eno Ic amtenance Ch kl' t Q . k f 'd f h It f ec IS . UIC re erence qu1 e ors e er 1nspec 10n Environmental Be aware of geological and Take appropriate actions to be prevailing weather conditions. prepared for events of nature.

Gutters deflect water runoff ar Clean out debris from trough. Do 6 Months are not functional. not step on gutter rails.

Water leakage at roof beam Rain seals may have been 6 Months joint seals. overlooked at installation. Silicon caulk at joint.

Excessive debris accumulatio Remove snow/mud debris from 6 Months around the shelter. sidewalls and keep all doors clea

Unwanted debris snow/ice anc Do not allow snow or ice to collec 6 Months accumulation on the shelter. on roof panels.

High winds or heavy storms Secure all tie-downs. As required forecast

WARNING Remove snow daily or when 2 Do not operate major shelter As required lbs. per square foot has components during heavy storms accumulated on or near Reinspect all systems after major supporting structures. storm or earthquake.

Optional Systems Service other customer See other Original Equipment supplied and installed systemi Manufacturer's (OEM) technical as recommended. specifications as required.

Lightning Check grounding as needed. Refer to OEM materials.

Protection

Fire Suppression Inspect per code regulations. Refer to OEM information.

Fire Alarms Test all alarms regularly. Refer to OEM requirement Fire Extinguishers Inspect per local regulations. Replace/recharge as required.

Exterior Lighting Check and test as needed. Refer to OEM specifications.

Safety Concerns Walking on bay roofs. Aluminum structures and fabric panels can easily support the weiqht of personnel.

Caution Roof fabric can be very slippery.

Safety harnesses and appropriat� footwear are required.

Important Adequate lifting equipment and approved ladders are required for working at heights over six feet.

Contact OSHA for detailed information.

Servicing electrical devices. Use qualified personnel.

13.4 10/01/08

Prior to Hurricane Season