Section J Atch 6 - Performance Plan 11 Jun 09.docx

DOCX document 149 KB Posted

Attached to
T-1/T-6 (USAF) Aircraft Maintenance Support Services, Pensacola NAS, FL
Solicitation number
FA3002-09-R-0044
Issued by

About this file

Attachment 6 Performance Plan

View the file

Other files

File Type Posted
09-R-0044 SF30 0003 canx 25 Jul 09.pdf PDF
09-R-0044-0002 22 Jul 09.pdf PDF
19 Jun RFP conformed thru 0001.pdf PDF
03 17 CSO Appendix 3FG GFP Training 10 Jul 09.pdf PDF
03 02 CSO Services Summary 10 Jul 09.pdf PDF
Government Response to Industry Comments.pdf PDF
03 01 CSO Description of Services 10 Jul 09.pdf PDF
03 11 CSO Appendix 3FB GFP EAID 10 Jul 09.pdf PDF
03 07 CSO Appendix 3D Required Reports 10 Jul 09.pdf PDF
FA3002-09-R-0044-0001.pdf PDF
02 01 CSO Applicable to All Services 10 Jul 09.pdf PDF
Atch 3 Schedule B 09-R-0044-0001 7 Jul 09.xls XLS spreadsheet
Pre-Proposal Conf Minutes 8 Jul 09.pdf PDF
Pensacola ACFT MX PreProposal Conf Briefing FINAL 8 Jul 09.pptx PPTX presentation
MFR Gov't response 7 Jul 09.pdf PDF
03-04-09 South Ramp Redesign Govt Approved.pdf PDF
AETC A47 Map directions.pptx PPTX presentation
Hangar Interior.pdf PDF
Notice Site Visit 20090702.pdf PDF
PWS Industry Questions.xls XLS spreadsheet
Sections H I and J Industry Questions.xls XLS spreadsheet
Section LM Industry Questions.xls XLS spreadsheet
Schedule B Industry Questions.xls XLS spreadsheet
Navy Instructions Part 2.pdf PDF
Navy Instructions Part 1.pdf PDF
NAVSEA OP5 7th rev.pdf PDF
19Jun09 Notice.pdf PDF
Attachment 5 Cover Page.doc DOC document
Schedule B 19 Jun 09.xlsx XLSX spreadsheet
WD 2005-3033 Rev 8 dated 26 May 09.pdf PDF
Attachment 2 Cover Page.doc DOC document
Attachment 11 Cover Page.docx DOCX document
09-R-0044 Jun 19.pdf PDF
Master PWS 19 Jun 09.pdf PDF
Manpower Matrix 15 June 09.xlsx XLSX spreadsheet
SCA Occ Index 5th Edition.pdf PDF
Section J Atch 7 - Small Business subcontracting checklist.docx DOCX document
Attachment 1 PWS.doc DOC document
Attachment 8 Cover Page.doc DOC document
Attachment 9 Past Performance Questionnaire 15 June.pdf PDF
Section J Attachment 10 Past Performance Consent Form.doc DOC document
Section J Atch 11 - Question and Comment Sheet 15 Jun 09.xlsx XLSX spreadsheet
CSO Pensacola PWS summary Sheet.xlsx XLSX spreadsheet
Attachment 7 Cover Page.doc DOC document
Attachment 3 Cover Page.doc DOC document
Attachment 9 Cover Page.doc DOC document
Attachment 10 Cover Page.doc DOC document
Section J Atch 8 - Past Performance Info Sheets.docx DOCX document
Attachment 4 Cover Page.doc DOC document
Attachment 6 Cover Page.doc DOC document
Show 40 more

Latest 50 of 67 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Aircraft Maintenance Services

Naval Air Station Pensacola, FL

11 Jun 09

This is the interim performance plan and will not be finalized until the contract is awarded and the contractor’s quality control process can be incorporated.

)Performance Plan

PERFORMANCE PLAN (PP)

for Naval Air Station Pensacola, FL Aircraft Maintenance Services

Coordination/Approval

The multi-functional team member signatures below indicate their review and acceptance of the PP for this service contract. These signatures indicate coordination on the performance plan at the time of development and will remain in effect until the plan is changed.

_______________________________________________________
TBD*TBD*
Chief Quality Assurance EvaluatorProgram Manager
479TH FTGHQ AETC/A4PM
DSN 922-XXXXDSN 487-9259, Comm: (210) 652-9259
Date:Date:
________________________________________________________
TBD*TBD*
Procuring Contracting OfficerAdministrative Contracting Officer
HQ AETC CONS/LGCK***CONS/LGCA
DSN:DSN XXX-XXXX
Date:Date:

TBD**

Quality Assurance Program Coordinator 479th FTG

DSN XXX-XXXX

Date:

Functional Commander Approval: Contractor Representative:

TBD*

Commander, 479th Flying Training GroupProgram Manager
Date:Date:

SECTION 1

1.1. Purpose: This Performance Plan (PP) has been developed and will be implemented in accordance with AFI 63-124, Performance-Based Services Acquisition (PBSA) guidelines. This plan will be used by members of the multi-functional team to ensure contractor compliance on the Aircraft Maintenance Services contract.

1.2. Objective: This PP is based on the premise that the Contractor is responsible for contract management and quality control, not the Government. The Government’s objective in having the service is to provide aircraft maintenance services for the 479th Fighter Training Group (FTG) at Naval Air Station Pensacola, FL.

1.3. Results: The results in managing this acquisition through this PP are to provide the 479 FTG with a support contract, with the ability to provide aircraft maintenance services. Success for this contract is defined as achieving these outcomes as stipulated in the Performance Work Statement (PWS) and that the government receives the services it is paying for.

1.4. Incentive Plan: Positive incentives as a result of performance that continually exceeds the performance objectives as outlined in the PWS may result in reduced surveillance and favorable Contractor Performance Assessment Reports (CPAR). Negative performance incentives include re-performance of the defective service in accordance with the Inspection of Services clause, reduction in price, negative CPAR reporting and/or increased surveillance.

1.5. Multi-Functional Team Roles & Responsibilities: The purpose of the multi-functional team is to create an environment that shapes and effectively executes acquisitions within their purview. The emphasis is on teamwork, trust, common sense and agility. These stakeholders are responsible for the acquisition throughout the life of the requirement, instituted under the authority of the senior leadership. Every representative within the multi-functional team brings to the team their unique level of expertise. The following members will participate in the performance management of this specific contract. Their roles and responsibilities are described as follows:

1.5.1. The Functional Commander/Functional Director (FC/FD): Has overall responsibility for identifying mission essential services and developing the necessary documents in accordance with DoDI 3020.37, Continuation of Essential DoD Contractor Services During Crisis, assigning primary and alternate Quality Assurance Evaluators (QAE) who will be available full time or as warranted by the procurement cycle, and reviewing contractor performance documentation on a regular basis to ensure performance is compatible with contract and mission objectives while supporting a higher level of contractor performance, and fostering synergistic partnerships.

1.5.2. The Program Manager (PM): Has the overall responsibility for initiating, managing and tracking the various programs that support the contract. The PM is the primary liaison between the Contracting Officer (CO) and the QAE. The PM is responsible for assisting in the preparation of requirements documents providing customers with a single contact point, monitoring the contractor’s overall performance of all assigned contracts, task orders and initiating contract changes and other supporting documentation.

1.5.3. The Contracting Officer (CO): Has overall responsibility for overseeing the contractor’s performance. The CO, through assigned QAE monitors contractor performance in the areas of contract compliance, contract administration, cost control reviewing the QAE assessment of the contractor’s performance; and resolving all differences between the QAE version and the contractor’s version of events. The CO is the only person with the authority to direct the contractor in the performance of his duties under the contract and to make interpretations of and changes to the contract. The CO and PM share joint responsibility in facilitating the multi-functional team meetings.

1.5.4. The Quality Assurance Program Coordinator (QAPC): The QAPC supports the multi-functional team in the development of contract requirements specifically ensuring that requirements are clearly stated and enforceable. Provides training to QAE’s on the contracting requirements associated with the quality assurance program. Provides training to the Functional Commander/Directors (FC/FD). The QAPC also provides assistance with market research and evaluation of the contractor’s Quality Control Plans.

1.5.5. The QAE: Has the responsibility for the technical monitoring of the contractor’s performance and assessing, recording, and reporting on the contractor’s compliance with the terms and conditions of the contract. Each QAE will be appointed in writing and will insure their availability to receive Phase 1 & Phase 2 training prior to performing contractor surveillance. Each QAE will maintain surveillance documentation, and notify the Functional Commander/Functional Director (FC/FD), through the PM and CO, of any significant performance deficiencies, and recommend improvements to the PMAP and PWS throughout the life of the contract.

1.5.6. The Contractor: Is responsible for complying fully with the terms and conditions of the contract, participating as a member of the multi-functional team in the post-award management phase, maintaining and implementing a Quality Control Plan (QCP) that compliments the performance plan, insuring that non-conforming contract services are identified, and corrected. When necessary revising the QCP to prevent recurrence. Tendering to the Government for acceptance only those services that conform to contract requirements and recommending any changes to the contract that will provide operations that are more effective or eliminate unnecessary costs. A monthly summary report of all QC actions shall be submitted in accordance to PWS para 3.1.8.10 and AFI 21-101.

SECTION 2

2.1. Methods of Inspection Applicable To This Contract: This contract is a Firm Fixed Price “C” type contract. Services are negotiated and the contractor invoices and is paid in monthly installments with the exception of the few cost reimbursable CLINS which are incidental to the performance of this contract. Services are inspected by the government QAE’s to ensure services rendered are in compliance with the PWS and the established thresholds for this effort.

2.1.1. Performance Metrics: Aircraft maintenance performance metrics are the metrics that are reported to higher headquarters and are summarized in the Performance Thresholds listed in the Services Summary of the PWS. QAE personnel track these metrics and validate the accuracy of them; however do not routinely conduct and/or document inspections in order to establish them. They are based on the contractor’s actual performance in meeting the threshold.

2.1.2. Periodic Inspection: These services are inspected using periodic or recurring basis. Periodic surveillance may be daily, weekly, monthly, quarterly, etc. Periodic Inspections are accomplished via technical and observations are inspections as defined in AFI 21-101, Chapter 18.

2.1.3. Random Inspection: These services are inspected on a random basis. Inspections conducted at random are selected by chance. A Random Number Generator can be used to determine the number, type, and frequency of the inspection to be accomplished.

2.1.4. 100% Inspection: These items are inspected on every instance they are performed. The QAE will determine acceptability and compliance with the performance threshold by monitoring and tracking each deliverable document. Technical documents and other deliverable documents will be reviewed for technical accuracy and compliance with technical directives. The results of this inspection may be used as the basis for actions (other than payment deductions) towards the contractor. In such cases, the Inspection of Services clause becomes the basis for the contracting officer’s actions.

2.1.5. Customer Complaint: The QAE is the primary point of contact for collection of all customer complaints. The Customer Complaint Record, or a similar locally devised form may be used for this purpose. All complaints and any resulting resolution of such complaints must be documented on the form. Customer complaint forms become a permanent part of the QAE surveillance records. The QAE will contact each customer involved with this contract periodically to assure there is an understanding of the contract requirement by all appropriate personnel and that they have a sufficient number of complaint forms.

2.2. Services Summary

2.2.1. Government Performance Thresholds (standards) – Government performance thresholds and calculation methods are listed in Section 3.2 of the PWS. The service provider shall meet all performance thresholds. The Service Summary (SS) performance thresholds and calculations may be revised based on detailed analysis recommendations by HQ AETC/A4PM and HQ AETC/A4MMA and monthly results. The service provider shall provide the monthly service summary report to the Chief QAP no later than the 10th day of the month (example October’s report is due NLT 10 November).

2.2.2. Asset Non-Availability: If Government actions such as sustained aircraft non-availability or supply difficulties significantly impair the SP's ability to meet established standards, the SP may request a waiver by submitting a written justification for noncompliance to the functional commander and contracting officer (CO). The Government may disapprove requests. Failure of the SP to initiate requisite aircraft or equipment repairs, including local manufacture and special repair requests; perform upkeep of equipment; or comply with any other standard procedures, as defined in this contract, applicable AF directives, and/or TOs, will result in the Government denying waiver requests.

2.2.3. Failure To Maintain Standards: For failure to maintain any monthly or quarterly contract standards (as applicable) listed in this Appendix, the SP shall provide a written explanation to the CO. The SP response to the CO shall explain the specific reason(s) or root cause(s) for not attaining identified standards. The SP shall also include actions taken to prevent recurrence. Corrective actions shall not task the Government in any way, and shall not be used as a basis to justify future noncompliance with the standards/requirements, without written approval from the CO. For failure to meet/maintain standards, the Government QAE may issue an AETC IMT 447, Routing and Review of QAE Reports, or a locally approved form..

2.3. Performance Status Notification: The QAE will ensure that the CO/PM is continually informed of contract performance status and any noted discrepancies during QAE surveillance. Results of all surveillance observations will be recorded on an AF Form 2420 or an equivalent form, noting date and time of inspection. The contractor’s General Manager or representative provides appropriate comments on action to be taken to correct the deficiencies. The QAE should then concur/non-concur with the contractor’s corrective action(s). If deficiencies are not corrected within five work days, the QAE should notify their Contracting Officer for further guidance. It is the responsibility of the QAE to immediately notify the CO of any and all contract non-conformance by the contractor.

2.4. Discrepancy Reporting: The QAE shall observe and document contractor performance using an AETC IMT 447 and will notify the CO/PM of any discrepancies noted during QAE inspections. This notification is for discrepancy correction only and does not indicate concurrence to the discrepancy. Only the CO is authorized to take formal action against the contractor.

2.5. Remedies for Unacceptable Performance: In accordance with FAR 52.246-4 -- Inspection of Services -- Fixed-Price.[footnoteRef:1] [1: The information provided was extracted from the Federal Acquisition Regulation on 13 April 2009 (52-246-4, dated Aug 1996)

2.5.1. Definition: “Services,” includes services performed, workmanship, and material furnished or utilized in the performance of services.

2.5.2. The Contractor shall provide and maintain an inspection system acceptable to the Government covering the services under this contract. Complete records of all inspection work performed by the Contractor shall be maintained and made available to the Government during contract performance and for as long afterwards as the contract requires.

2.5.3. The Government has the right to inspect and test all services called for by the contract, to the extent practicable at all times and places during the term of the contract. The Government shall perform inspections and tests in a manner that will not unduly delay the work.

2.5.4. If the Government performs inspections or tests on the premises of the Contractor or a subcontractor, the Contractor shall furnish, and shall require subcontractors to furnish, at no increase in contract price, all reasonable facilities and assistance for the safe and convenient performance of these duties.

2.5.5. If any of the services do not conform with contract requirements, the Government may require the Contractor to perform the services again in conformity with contract requirements, at no increase in contract amount. When the defects in services cannot be corrected by reperformance, the Government may --

2.5.5.1 Require the Contractor to take necessary action to ensure that future performance conforms to contract requirements; and

2.5.5.2 Reduce the contract price to reflect the reduced value of the services performed.

2.5.6. If the Contractor fails to promptly perform the services again or to take the necessary action to ensure future performance in conformity with contract requirements, the Government may --

2.5.6.1 By contract or otherwise, perform the services and charge to the Contractor any cost incurred by the Government that is directly related to the performance of such service; or

2.5.6.2 Terminate the contract for default.

2.6. Non-Service Summary Items: Quality performance is expected on all contract requirements (Non-Service Summary) items by the contractor. All Non-Service Summary items, are susceptible be inspected by the QAE.

2.7. Certification of Services: Certification of services is performed by the QAE and the 479th FTG Resource Advisor (RA) at the end of each period of performance (determined upon issue of the Task Order) via Wide Area Work Flow (WAWF) system. At the end of each billing period the contractor inputs invoice information in the WAWF system. The WAWF automatically notifies the appropriate QAE via email of pending invoice. The RA accesses WAWF and verifies accuracy of the contractor’s data. If data is correct the QAE certifies invoice and payment is affected by the Defense Finance Accounting System. If the QAE encounters errors in the contractor’s invoice, the QAE will resolve with the CO/PM. If the contractor disagrees with the QAE the issue is forwarded to the CO for resolution. The QAE and the RA will maintain a copy of the invoice in their respective contract files.

SECTION 3

3.1. Program Management Review

3.1.1. A monthly Program Management Review or Progress Meeting will be chaired by the Functional Commander, and held usually during the 3rd week of each month. It will be attended by the Service Provider manager and his supervisors as he sees fit, the Chief QAE and his QAEs as they are available, the Contracting Officer or contract administrator and other selected representatives such as the 479th FTG OG/CD, Resource Advisor, military QA supervision or any other representation as deemed necessary by the FC. As a minimum, attendees will review government and contractor quality evaluations from the previous month and the Chief QAE will provide the service provider with a verbal assessment of the prior month’s performance using CPAR evaluation criteria. The ACO shall keep minutes of the proceedings and develop an agenda for each meeting.

Performance Plan NAS Pensacola ACFT MX Services image1.jpeg image2.jpeg image3.jpeg

File details come from the government source that posted it. Updated .