Cover (R&M) Rpr
FA2521-11-R-0052
BID SCHEDULE
for
| Indefinite Delivery, Indefinite Quantity Roof Repair |
| SXHT 12-1017 IDIQ- REPAIR MAINT ROOFS, VAR FAC |
Revision 2 at
| Patrick Air Force Base |
| Florida |
| Project Precentage: 100% |
| Dated: June 2011 |
| IDIQ 100% Government Estimate Base Year = | $0 |
| IDIQ 100% Government Estimate Option Year 1= | $0 |
| IDIQ 100% Government Estimate Option Year 2= | $0 |
| IDIQ 100% Government Estimate Option Year 3= | $0 |
| IDIQ 100% Government Estimate Option Year 4= | $0 |
| Total IDIQ Contract Value Base + Option Years = | $0 |
BID SCHEDULE - BASE YR
| ITEM | SCOPE OF WORK DESCRIPTION | SPEC./DTL. REFERENCE | UNIT | EST QUANT | UNIT | |
| COST | TOTAL | |||||
| Division 02 - Site Construction (Unless otherwise noted, items in this division shall be "removed and disposed" of accordance with Federal, State, County and City ordinances.) | ||||||
| Section 02 41 00 - Selective Demolition | ||||||
| A0001 | Built-up asphalt roofing roof membrane with aggregate surfacing down to the roof deck surface. To include, but not limited to, membrane, penetration and wall flashings, cants, crickets, insulation up to 6" thick, and all fasteners. Minimum Quantity per Building per delivery order: 500 SF. | SPEC: 02 41 00 | SF | 24,000 | ||
| A0002 | Built-up coal tar pitch roofing roof membrane with aggregate surfacing down to the roof deck surface. To include, but not limited to, membrane, penetration and wall flashings, cants, crickets, insulation up to 6" thick, and all fasteners. Minimum Quantity per Building per delivery order: 500 SF. | SPEC: 02 41 00 | SF | 7,000 | ||
| A0003 | Built-up smooth surfaced asphalt roofing roof membrane, modified bitumen roofing with granular surface cap sheet, fully adhered single ply roofing (including any of the following membrane types: PVC, EPDM, PIB and other membrane roofing types), and mechanically fastened single ply roofing (including any of the following membrane types: PVC, EPDM, PIB and other membrane roofing types) down to the roof deck surface. To include, but not limited to, membrane, penetration and wall flashings, cants, crickets, insulation up to an average of 6 " thick across entire roof section being stripped, and all fasteners. Minimum Quantity per Building per delivery order: 500 SF. | SPEC: 02 41 00 | SF | 22,000 | ||
| A0004 | Built-up asphalt roofing roof membrane with aggregate surfacing, or built-up coal tar pitch roofing, or built-up smooth surfaced asphalt roofing. Include membrane, penetration & wall flashings & membrane fasteners. NOT TO INCLUDE include insulation, crickets and insulation fasteners. Minimum Quantity per Building per delivery order: 500 SF. | SPEC: 02 41 00 | SF | 7,000 | ||
| A0005 | Aggregate ballast. Include spudding-back and vacuuming loose aggregate from entire roof surface. Minimum Quantity per Building per delivery order: 250 SF. | SPEC: 02 41 00 | SF | 6,500 | ||
| A0006 | Additional insulation exceeding average 6" thick up to additional average 6" thick, from entire roof surface area. Minimum Quantity per Building per delivery order: 500 SF. | SPEC: 02 41 00 | SF | 3,500 | ||
| A0007 | Spray polyurethane foam roofing materials with top coating from partial or entire roof deck surface. Average insulation thickness is 4". Minimum Quantity per Building per delivery order: 250 SF. | SPEC: 02 41 00 | SF | 250 | ||
| A0008 | Fully adhered single ply roofing (including PVC, EPDM, PIB and other membrane roofing). Include membrane, penetration & wall flashings. NOT TO INCLUDE insulation, crickets, cants and insulation fasteners. Minimum Quantity per Building per delivery order: 250 SF. | SPEC: 02 41 00 | SF | 800 | ||
| A0009 | Mechanically fastened single ply roofing (including PVC, EPDM, PIB and other membrane roofing) down to the deck. Include membrane, penetration & wall flashings and membrane fasteners. NOT TO INCLUDE insulation, crickets and insulation fasteners. Minimum Quantity per Building per delivery order: 250 SF. | SPEC: 02 41 00 | SF | 800 | ||
| A0010 | Metal roof panels w/exposed or concelaed fasteners and abandoned equipment capped curb and/or opening, including edge and rake flashings to the structural sub-framing or decking. Include all clips, anchors, fasteners and accessories. Minimum Quantity per Building per delivery order: 100 SF. | SPEC: 02 41 00 | SF | 2,500 | ||
| A0011 | Sheet metal flashing items with cleat and associated fasteners, cap flashing, expansion joint covers, parapet coping caps, gravel stop, drip edge and other similar items. Minimum Quantity per Building per delivery order: 25 LF. | SPEC: 02 41 00 | LF | 10,000 | ||
| A0012 | Termination sheet metal items including counter flashings, skirt flashings, reglets and termination bars at walls or curbs. Minimum Quantity per Building per delivery order: 25 LF. | SPEC: 02 41 00 | LF | 1,000 | ||
| A0013 | Metal pitch pans including grout and sealant. (up to 6"x6"x4" tall) | SPEC: 02 41 00 | EA | 50 | ||
| A0014 | Metal gutter and / or downspout assembly including anchors, hangars, straps, and fasteners. Minimum Quantity per Building per delivery order: 25 LF. | SPEC: 02 41 00 | LF | 2,000 | ||
| A0015 | Metal scupper assembly including anchors, associated flashing, hangars, straps, and fasteners. | SPEC: 02 41 00 | EA | 50 | ||
| A0016 | Metal conductor box and associated flashings at scupper locations including anchors, hangars, straps, and fasteners. | SPEC: 02 41 00 | EA | 50 | ||
| A0017 | Wood blocking including anchors, hangars, straps, and fasteners. Minimum Quantity per Building per delivery order: 10 BF. | SPEC: 02 41 00 | BF | 5,000 | ||
| A0018 | Plywood including anchors, straps, and fasteners. Minimum Quantity per Building per delivery order: 16 SF. | SPEC: 02 41 00 | SF | 1,200 | ||
| A0019 | Cementitious wood fiber roof deck/form board (Tectum). Up to 2-1/2" thick. Minimum Quantity per Building per delivery order: 50 SF. | SPEC: 02 41 00 | SF | 250 | ||
| A0020 | Damaged, deteriorated and/or heavily corroded bulb tee supports and replace steel bulb tee supports to perform associated roof work. Minimum Quantity per Building per delivery order: 10 LF. | SPEC: 02 41 00 | LF | 450 | ||
| A0021 | Remove, protect, store and re-install corrugated fiberglass or fluted metal wall panels with exposed fasteners to perform associated roof work. Minimum Quantity per Building per delivery order: 50 SF. | SPEC: 02 41 00 | SF | 500 | ||
| A0022 | Metal hat channels, purlins, girts, angles and other supports associated with roof and wall panels (metal, fiberglass, or plastic). Include all associated clips, anchors and fasteners. Minimum Quantity per Building per delivery order: 100 LF. | SPEC: 02 41 00 | LF | 200 | ||
| A0023 | De-energize, remove and dispose of abandoned and/or deteriorated mechanical equipment. Including, but not limited to, piping, fittings, conduit, wiring, supports, straps, and items usually assoicated with rooftop mechanical equiptment. Minimum Quantity per Building per delivery order: 10 LF. | SPEC: 02 41 00 | LF | 125 | ||
| Section 02 82 13 - Asbestos Abatement | ||||||
| A0024 | CLASS I and / or CLASS II asbestos containing roof materials (ACRM) roof membrane. Minimum Quantity per Building per delivery order: 10 SF. | SPEC: 02 82 13 | SF | 400 | ||
| A0025 | Corrugated asbestos wall panels ("Transite" or equivalent). Minimum Quantity per Building per delivery order: 20 SF. | SPEC: 02 82 13 | SF | 100 | ||
| A0026 | Cementitious asbestos fiber roof deck/form board ("Transite" or equivalent). Minimum Quantity per Building per delivery order: 20 SF. | SPEC: 02 82 13 | SF | 100 | ||
| Section 02 83 13 - Lead in Construction | ||||||
| A0027 | Lead Based Coatings from steel substrate. Minimum Quantity per Building per delivery order: 20 SF. | SPEC: 02 83 13 | SF | 250 | ||
| A0028 | Lead Based Coatings from concrete, CMU, or wood substrate. Minimum Quantity per Building per delivery order: 20 SF. | SPEC: 02 83 13 | SF | 250 | ||
| Section 03 52 00 - Roof Decking, Cast-in-Place Low Density Concrete (Unless otherwise noted, items in this division include "removal and disposal" in accordance with Federal, State, County and City ordinances. "Furnish and install" new components.) | ||||||
| A0029 | Damaged lightweigth concrete deck and replace with new lightweight concrete. Minimum size of each repair – 3" deep over 10 SF (2.5 CF) or equivalent volume. | SPEC: 03 52 00 | CF | 50 | ||
| A0030 | Damaged lightweight insulation concrete down to the form board or deck and replace with new lightweight insulating concrete. Minimum size of each repair – 3" deep over 10 SF (2.5 CF) or equivalent volume. | SPEC: 03 52 00 | CF | 50 | ||
| Division 04 - Masonry (Unless otherwise noted, new items in this division shall be "furnished and installed" and old components shall be "removed and disposed" of accordance with Federal, State, County and City ordinances.) | ||||||
| Section 04 01 20 - Maintenance of Unit Masonry | ||||||
| A0031 | Water blast clean existing masonry surface in accordance with paint manufacturer's recommendations. Minimum Quantity per Building per delivery order: 200 SF. | SPEC: 04 01 20 | SF | 500 | ||
| A0032 | Concrete masonry units to include grouting, tuck pointing, formwork, and supports . Perform work in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 30 SF. | SPEC: 04 01 20 | SF | 250 | ||
| Division 05 - Metals (Unless otherwise noted, items in this division shall be "fabricated/furnished and installed".) | ||||||
| Section 05 30 00 - Steel Decks | ||||||
| A0033 | Shop primed structural steel roof decking; including 1" to 2" deep flutes, 24 gauge or thinner. Include the installation of associated items, including panel edge closures and miscellaneous perimeter and wall items. Minimum Quantity per Building per delivery order: 20 SF. | SPEC: 05 30 00 | SF | 2,500 | ||
| Section 05 40 00 - Cold-Formed Metal Framing | ||||||
| A0034 | Cold-formed metal framing members or metal soffit framing, to include saddles, cant strips, curbs for scuttles and ventilators, and nailers attached at the tops of concrete or masonry curbs, expansion joints and roof edges. Framing members are 4" to 8" wide by 18 gauge or thinner. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 05 40 00 | LF | 100 | ||
| A0035 | Retrofit sub-purlin and/or formed shaped framing system mechanically fastened to existing framing and/or substrate in accordance with manufacturer's recommendations. Include all anchors, fasteners, clips, connectors and accessories. Minimum 16 gauge thickness. Minimum Quantity per Building per delivery order: 100 LF | SPEC: 05 40 00 paragraph 2.3 | LF | 700 | ||
| Section 05 50 00 - Metal Fabrication | ||||||
| A0036 | Shop primed steel materials including but not limited to: weld plates, angles for casting into concrete, anchor bolts, steel pipe sleeves, and wedge-type inserts to be cast into concrete or built into unit masonry, framing, supports and fabricated items for applications that are not specified in other specification sections. Minimum Quantity per Building per delivery order: 25 lbs. | SPEC: 05 50 00 | LB | 500 | ||
| Section 05 51 00 - Metal Stairs | ||||||
| A0037 | Remove, dispose of, and replace areas of deteriorated or damaged steel grate treads and platforms of industrial-type stair systems. Minimum Quantity per Building per delivery order: 10 SF. | SPEC: 05 51 00 | SF | 50 | ||
| A0038 | Remove, dispose of, and replace areas of deteriorated or damaged steel tube railings and/or guards attached to metal stairs and/or adjacent walls of industrial-type stair systems. Minimum Quantity per Building per delivery order: 10 LF. | SPEC: 05 51 00 | LF | 45 | ||
| A0039 | Clean, prime, paint and finish areas of deteriorated existing steel grate treads and platforms of industrial-type stair systems. Perform work in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 20 SF. | SPEC: 05 51 00 | SF | 35 | ||
| A0040 | Clean, prime, paint and finish areas of deteriorated existing steel tube railings and/or guards guardrails attached to metal stairs and/or adjacent walls of industrial-type stair systems or guard rails. Perform work in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 05 51 00 | LF | 35 | ||
| Section 05 51 33 - Metal Ladders | ||||||
| A0041 | Aluminum lockable ladder security door and roof hatch at the base and top respectively - 14 gauge aluminum sheet, 8 feet tall door at the base and 36" x 24" (min.), roof hatch at top. Both door and roof hatch must be able to withstand a 200-pound force applied at any point from any direction. This is applicable to aluminum or FRP ladder systems. | SPEC: 05 51 33 DWG. 8.09 and 8.10 | EA | 12 | ||
| A0042 | Clean, prime, paint and finish areas of deteriorated existing roof access ladder system, which includes but not limited to, side rails, rungs, cage and/or mounting brackets. Perform work in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 05 51 33 | LF | 50 | ||
| Section 05 53 00 - Metal Grating | ||||||
| A0043 | Aluminum grating for elevated platforms and walkways. Minimum Quantity per Building per delivery order: 30 SF. | SPEC: 05 53 00 | SF | 50 | ||
| Division 06 - Wood and Plastics (Unless otherwise noted, items in this division shall be "fabricated/furnished and installed".) | ||||||
| Section 06 10 00 - Rough Carpentry | ||||||
| A0044 | Re-secure existing roof nailers to roof deck and/or substrate to meet current uplift requirements which includes an average size of 6 inches wide by 4 inches thick (double 2x 6 typical). Minimum Quantity per Building per delivery order: 25 LF. | SPEC: 06 10 00 | LF | 300 | ||
| A0045 | Preservative-treated wood roof nailers, which includes wood saddles or crickets, cant strips, curbs for scuttles and ventilators, and wood nailers bolted to tops of concrete or masonry curbs and at expansion joints. | SPEC: 06 10 00 | BF | 500 | ||
| A0046 | Preservative-treated wood roof nailers, to meet current uplift requirements which includes perimeter of roof, around openings through roof, and where roofs abut walls, curbs, and other vertical surfaces. | SPEC: 06 10 00 | BF | 500 | ||
| A0047 | 5/8" up to 3/4" plywood roof or wall sheathing. Minimum Quantity per Building per delivery order: 32 SF. | SPEC: 06 10 00 paragraph 2.2 | SF | 300 | ||
| A0048 | Roof decking, which includes decking 2 inches thick with single tongue and groove; V-jointed, matched and dressed and/or fabricated laminated lumber decking with interlocking tongue and groove joints. Minimum Quantity per Building per delivery order: 32 SF. | SPEC: 06 10 00 paragraph 2.3.1 | SF | 200 | ||
| A0049 | Preservative-treated lumber, which includes 1X or 2X nominal thicknesses. Minimum Quantity per Building per delivery order: 10 BF. | SPEC: 06 10 00 paragraph 2.3.2 | BF | 750 | ||
| Section 06 71 33 - Fiberglass Reinforced Plastic (FRP) Ladders | ||||||
| A0050 | FRP ladder system, which includes but limited to, side rails, rungs, mounting brackets, without cage and related safety rail system. Minimum Quantity per Building per delivery order: 7 LF. | SPEC: 06 71 33 | LF | 110 | ||
| Section 06 73 01 - Fiberglass Reinforced Plastic (FRP) Grating | ||||||
| A0051 | FRP grating for elevated platforms and walkways. Minimum Quantity per Building per delivery order: 30 SF. | SPEC: 06 73 01 | SF | 250 | ||
| Section 06 82 14 - Fiberglass Reinforced Plastic (FRP) Pipe and Tube Railings | ||||||
| A0052 | FRP pipe and/or tube side mounted guardrail system. Minimum Quantity per Building per delivery order: 12 LF. | SPEC: 06 82 14 | LF | 60 | ||
| A0053 | FRP pipe and/or tube base mounted guardrail system. Minimum Quantity per Building per delivery order: 12 LF. | SPEC: 06 82 14 | LF | 60 | ||
| Division 07 - Thermal and Moisture Protection (Unless otherwise noted, items in this division include "removal and disposal" in accordance with Federal, State, County and City ordinances. "Furnish/fabricate and install" new components.) | ||||||
| Section 07 01 50 / 07 01 50.62 / 07 01 50.82 - Roofing Repairs | ||||||
| A0054 | Spud-back and vacuum the loose existing gravel from aggregate-surfaced built-up bituminous roofing with a power broom to existing substrate. Remove blisters, ridges and buckles or wet materials. Hot mop or mechanically fasten recovery board with (2) glass-fiber felts lapping each sheet (18) inches over preceding sheet. Install 250 mil modified bitumen highly reflrective (min. reflectance value = 0.70) top ply in hot asphalt over patch area. Minimum Quantity per Building per delivery order: 30 SF. | SPEC: 07 01 50 and 07 01 50.62 | SF | 1,500 | ||
| A0055 | Remove and dispose of or relocate existing concrete roof pavers or splash blocks from roof or ground. | SPEC: 07 01 50 | EA | 30 | ||
| A0056 | Replace pitch pan filler. Use grout filler and 1" thick of 1-Part self-leveling pourable sealer to slope pan filler for adequate moisture run-off. (up to 8"x8"x4" tall) | SPEC: 07 01 50 DWG 2.21 | EA | 30 | ||
| A0057 | 1/2" or 5/8" treated gypsum core with embedded glass mat (both faces) recovery board over roof insulation and/or roofing membrane. Mechanically fasten to the existing roof deck in accordance with manufacturer’s recommendations. Furnish and install (1) SBS 140 mil inter-ply sheet along with (1) SBS 138 mil highly reflrective (min. reflectance value = 0.70) cap sheet. Minimum Quantity per Building per delivery order: 100 SF. | SPEC: 07 01 50 and 07 01 50.82 | SF | 14,000 | ||
| A0058 | 12" high, 4" I.D. relief vent in accordance with manufacturer's recommendation. | SPEC: 07 01 50 | EA | 15 | ||
| A0059 | 2-ply temporary asphalt built-up roofing with a flood coating of asphalt. Minimum Quantity per Building per delivery order: 100 SF. | SPEC: 07 01 50 and 07 01 50.62 | SF | 5,000 | ||
| A0060 | Replace base flashings up to 24" height at parapets, curbs and walls with 2 ply (140 mil/138 mil highly reflrective top sheet (min. reflectance value = 0.70) ) modified bitumen base flashing membranes, stainless steel termination bar in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 50 LF. | SPEC: 07 01 50.82 DWG 1.01 | LF | 700 | ||
| Section 07 14 16 - Fluid-applied Waterproofing | ||||||
| A0061 | Prepare roof surface, furnish and install flexible acrylic highly reflrective (min. reflectance value = 0.70) elastomeric coating, fluid applied in minimum two successive stages to form one continuous, seamless, watertight membrane in accordance with manufacturer’s recommendations; 25 mil minimum total cured system thickness. Minimum Quantity per Building per delivery order: 1000 SF. | SPEC: 07 14 16 | SF | 8,000 | ||
| A0062 | Prepare roof surface, furnish and install fabric reinforced flexible acrylic elastomeric coating at flashing areas, fluid applied in minimum two successive stages to form one continuous, seamless, watertight membrane in accordance with manufacturer’s recommendations; 45 mil minimum total cured system thickness. Minimum Quantity per Building per delivery order: 100 SF. | SPEC: 07 14 16 | SF | 1,000 | ||
| A0063 | Remove rust and scale from metal surfaces of the existing roofing system in areas which are to receive roof coatings by abrasive cleaning disks and/or wire brushing to manufacturer’s specified conditions unless otherwise indicated. Minimum Quantity per Building per delivery order: 25 SF. | SPEC: 07 14 16 | SF | 1,000 | ||
| Section 07 22 16.22 - Roof Board Insulation (Polyisocyanurate) | ||||||
| A0064 | Vapor retarder to roof deck surface. Minimum Quantity per Building per delivery order: 200 SF. | SPEC: 07 22 16.22 paragraph 2.4 | SF | 1,000 | ||
| A0065 | 1-1/2-inch up to 3-1/2-inch polyisocyanurate insulation board system. Mechanically fasten to the substrate in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 200 SF. | SPEC: 07 22 16.22 | SF | 8,000 | ||
| A0066 | 1-1/2-inch up to 3-1/2-inch polyisocyanurate insulation board system. Fully adhere insulation board in hot asphalt to appropriate substrate in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 200 SF. | SPEC: 07 22 16.22 | SF | 15,000 | ||
| A0067 | 1-1/2-inch up to 3-1/2-inch polyisocyanurate insulation board system. Secure insulation to deck/substrate with non-flammable adhesives for application of insulation or underlayment in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 200 SF. | SPEC: 07 22 16.22 | SF | 4,000 | ||
| A0068 | Tapered polyisocyanurate insulation board system. Provide positive drainage with one (1) layer of factory tapered roof insulation at 1/8-inch per foot minimum. Secure total thickness by fully adhering with hot asphalt, or with nonflammable adhesives, in accordance with manufacturer's recommendations. Average tapered insulation system thickness 4 inches as measured from roof deck including minimum thickness per manufacturer's requirements. Minimum Quantity per Building per delivery order: 300 SF. | SPEC: 07 22 16.22 | SF | 2,000 | ||
| A0069 | Tapered polyisocyanurate insulation board system. Provide positive drainage with one (1) layer of factory tapered roof insulation at 1/8-inch per foot minimum. Mechanically fasten base layer to the substrate in accordance with manufacturer's recommendations. Apply successive layers of insulation in hot asphalt or with nonflammable adhesive. Average tapered insulation thickness 4 inches as measured from roof deck including minimum thickness per manufacturer's requirement. Minimum Quantity per Building per delivery order: 300 SF. | SPEC: 07 22 16.22 | SF | 5,000 | ||
| A0070 | Tapered polyisocyanurate insulation board system. Provide positive drainage with one (1) layer of factory tapered roof insulation at 1/4-inch per foot minimum. Secure total thickness by fully adhering with hot asphalt, or with nonflammable adhesives, in accordance with manufacturer's recommendations. Average tapered insulation system thickness 5-1/2 inches as measured from roof deck including minimum thickness per manufacturer's requirements. Minimum Quantity per Building per delivery order: 200 SF. | SPEC: 07 22 16.22 | SF | 1,000 | ||
| A0071 | Tapered polyisocyanurate insulation board system. Provide positive drainage with one (1) layer of factory tapered roof insulation at 1/4-inch per foot minimum. Mechanically fasten base layer to the substrate in accordance with manufacturer's recommendations. Apply successive layers of insulation in hot asphalt or with nonflammable adhesive. Average tapered insulation thickness 5-1/2 inches as measured from roof deck including minimum thickness per manufacturer's requirement. Minimum Quantity per Building per delivery order: 200 SF. | SPEC: 07 22 16.22 | SF | 7,000 | ||
| A0072 | Preformed crickets and tapered edge strips of polyisocyanurate insulation board. Provide positive drainage with one (1) layer of factory tapered roof insulation at 1/4-inch per foot Minimum Quantity per Building per delivery order slope. Fully adhere insulation board to existing substrate. Average insulation thickness (3) inches. Minimum Quantity per Building per delivery order: 50 SF. | SPEC: 07 22 16.22 | SF | 800 | ||
| A0073 | Preformed cant strips of polyisocyanurate insulation board. Incline face of cant strips to be 45 degrees with vertical height of (4) inch. Minimum Quantity per Building per delivery order: 20 LF. Secure in accordance with manufacturer's recommendations. | SPEC: 07 22 16.22 | LF | 800 | ||
| A0074 | Supplemental fastening of insulation to prepared metal/wood/gypsum/screwable deck substrate with penetrating type fasteners and preformed disks in accordance with manufacturer's recommendations. Provide 1 additional fastener per square foot for additional securment. Minimum Quantity per Building per delivery order: 200 SF. | SPEC: 07 22 16.22 | SF | 4,000 | ||
| Section 07 22 16.23 - Roof Board Insulation (Expanded Polystyrene-EPS) | ||||||
| A0075 | Vapor retarder to roof deck surface. Minimum Quantity per Building per delivery order: 100 SF. | SPEC: 07 22 16.23 paragraph 2.4 and 2.7.1 | SF | 700 | ||
| A0076 | 1-1/2-inch up to 3-1/2-inch EPS insulation board. Mechanically fastened or fully adhere in hot asphalt or with nonflammable adhesive to the substrate in accordance with manufacturer’s recommendations or per warranty recommendations. Minimum Quantity per Building per delivery order: 200 SF. | SPEC: 07 22 16.23 | SF | 3,000 | ||
| Section 07 31 13 - Asphalt Shingles | ||||||
| A0077 | Self-adhering sheet underlayment; wrinkle free, on roof deck. Install in direction to shed water. Lap sides not less than 3-1/2 inches. Lap ends not less than 6 inches staggered 24 inches between courses. Roll laps with roller. Minimum Quantity per Building per delivery order: 100 SF. | SPEC: 07 31 13 DWG. 4.01, 4.02 and 4.03 | SF | 4,000 | ||
| A0078 | Fiberglass Reinforced Asphalt Shingles, Mineral granule-surfaced asphalt shingles, self-sealing, square tab, strip, fungus-resistant architectural shingles weighing not less than 290 pounds per 100 SF in accordance with manufacturer’s recommendations. Install hip shingles, ridge shingles, and miscellaneous perimeter/ trim flashings. Minimum Quantity per Building per delivery order: 200 SF. | SPEC: 07 31 13 DWG. 4.01, 4.02 and 4.03 | SF | 3,500 | ||
| A0079 | Standard high-density polypropylene or other UV-stabilized plastic ridge vent with non-woven geo-textile filter strips and external deflector baffles for use under ridge shingles in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 50 LF. | SPEC: 07 31 13 | LF | 250 | ||
| Section 07 32 00 - Concrete and Clay Tile Roofing | ||||||
| A0080 | Self-adhering sheet underlayment, granular surfaced; wrinkle free, on roof deck. Install at locations indicated on construction documents, lapped in direction to shed water. Lap sides not less than 3-1/2 inches. Lap ends not less than 6 inches staggered 24 inches between courses. Roll laps with roller. | SPEC: 07 32 00 | SF | 4,500 | ||
| A0081 | New Roof: Molded or extruded-concrete roof tile units of shape and configuration matching existing conditions, with integral color, and free of surface imperfections. Include the installation of associated items, including tile end closures, rake and ridge tile, clips, cleats and miscellaneous perimeter and trim flashings. Provide with fastening for hurricane wind uplift criteria. Minimum Quantity per Building per delivery order: 300 SF. New roof tiles to match that of existing tiled roofs. | SPEC: 07 32 00 DWG. 5.01 through 5.11 | SF | 5,000 | ||
| A0082 | Existing Roof: Molded or extruded-clay roof tile units of shape and configuration matching existing conditions, with integral color, and free of surface imperfections. Include the installation of associated items, including tile end closures, rake and ridge tile , clips, cleats and miscellaneous perimeter and trim flashings. Provide with fastening for hurricane wind uplift criteria. Minimum Quantity per Building per delivery order: 30 SF. New roof tiles to match that of existing tiled roofs. | SPEC: 07 32 00 DWG. 5.01 through 5.11 | SF | 1,200 | ||
| Section 07 41 13 - Metal Roof Panels | ||||||
| A0083 | Coated (colored) Aluminum-Zinc Alloy-Coated Steel Roof panels secured with exposed fasteners in accordance with manufacturer's recommendations. Include the installation of associated items, including panel end closures, rake flashings, eave flashings, valleys, ridges, clips, cleats and miscellaneous perimeter and trim flashings. Minimum Quantity per Building per delivery order: 400 SF. | SPEC: 07 41 13 DWG. 6.01, 6.03, 6.05, 6.07 and 6.08 | SF | 3,000 | ||
| A0084 | Coated (colored) Aluminum-Zinc Alloy-Coated Steel Roof panels secured with concealed fasteners in accordance with manufacturer's recommendations. Include the installation of associated items, including panel end closures, rake flashings, eave flashings, valleys, ridges, clips, cleats and miscellaneous perimeter and trim flashings. Minimum Quantity per Building per delivery order: 400 SF. | SPEC: 07 41 13 Dwg. 6.02, 6.04, 6.06, 6.12 and 6.17 | SF | 500 | ||
| A0085 | Self-adhering sheet underlayment, smooth surfaced; wrinkle free, on roof deck. Install at locations indicated on construction documents, lapped in direction to shed water. Lap sides not less than 3-1/2 inches. Lap ends not less than 6 inches staggered 24 inches between courses. Roll laps with roller. | SPEC: 07 41 13 | SF | 500 | ||
| Section 07 41 33 / 07 42 33 - Fiberglass Reinforced Plastic (RFP) Roof / Wall Panels | ||||||
| A0086 | Furnish and install integral colored FRP Roof / Wall panels , secured with exposed fasteners in accordance with manufacturer’s recommendations. Include the installation of associated items, including panel end closures, rake flashings, eave flashings, valleys, ridges, clips, cleats and miscellaneous perimeter and trim flashings. Minimum Quantity per Building per delivery: order 200 SF. | SPEC: 07 41 33 | SF | 800 | ||
| Section 07 42 13 - Metal Wall Panels | ||||||
| A0087 | Furnish and install coated (colored) 22 gauge Aluminum-Zinc Alloy-Coated Steel Wall panels, secured with exposed fasteners in accordance with manufacturer’s recommendations. Include the installation of associated items, including panel end closures, corner flashings, clips, cleats and miscellaneous perimeter and trim flashings. Minimum Quantity per Building per delivery order: 500 SF. | SPEC: 07 42 13 Dwg. 6.01t- 6.30 | SF | 1,000 | ||
| A0088 | (CLIN Deleted) | |||||
| Section 07 52 16.14 / 07 52 16.15 - SBS Modified Bituminous Membrane Roofing | ||||||
| A0089 | Asphalt roof deck primer. Minimum Quantity per Building per delivery order: 100 SF. | SPEC: 07 52 16.14 | SF | 18,000 | ||
| A0090 | 138 mil (minimum) SBS modified bitumen up to 24" height highly reflective (min. initial reflectivity value = 0.78) cap sheet with 140 mil 2nd modified bitumen ply in cold-applied adhesive (non-flammable) over prepared surface of repair area in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 50 SF. | SPEC: 07 52 16.14 | SF | 1,500 | ||
| A0091 | 138 mil (minimum) SBS modified bitumen highly reflective (min. initial reflectivity value = 0.78) cap sheet torch applied with 2nd 140 mil modified bitumen ply torch applied over prepared surface of repair area in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 50 SF. | SPEC: 07 52 16.14 | SF | 18,000 | ||
| A0092 | 138 mil (minimum) SBS modified bitumen highly reflective (min. initial reflectivity value = 0.78) cap sheet with 140 mil 2nd modified bitumen ply hot mopped over prepared surface of repair area in accordance with manufacturer’s recommendations. Torch apply the cap sheet. Minimum Quantity per Building per delivery order: 50 SF. | SF | 3,000 | |||
| A0093 | 138 mil (minimum) highly reflective (min. initial reflectivity value = 0.78) SBS modified bituminous cap membrane with fiberglass base sheet over prepared wood deck substrate. Secure base sheet to with penetrating type fasteners and preformed disks into the deck/substrate in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 200 SF. | SPEC: 07 52 16.14 | SF | 1,000 | ||
| A0094 | Highly reflective (min. initial reflectivity value = 0.78) 138 mil (minimum) SBS modified bituminous membrane cap sheet and 140 mil 2nd modified bitumen ply with polyester base sheet over prepared wood deck substrate. Secure base sheet to with penetrating type fasteners and preformed disks into the deck/substrate in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 200 SF. | SPEC: 07 52 16.14 | SF | 12,500 | ||
| A0095 | Highly reflective (min. initial reflectivity value = 0.78) 138 mil (minimum) SBS modified bituminous membrane, 2nd 140 mil modified bitumen ply, with fiberglass or polyester base sheet over prepared concrete or lightweight deck substrate in accordance with manufacturer’s recommendations. Apply sheet in full mopping of hot Type 4 asphalt. Minimum Quantity per Building per delivery order: 200 SF. | SPEC: 07 52 16.14 | SF | 12,000 | ||
| A0096 | 2-ply SBS 140/138 mil (minimum) modified bitumen strip flashing with Highly reflective (min. initial reflectivity value = 0.78) cap sheet and sheet flashing in angles formed where roof deck abuts walls, curbs, ventilators, pipes, and other vertical surfaces. Provide granular surfaced top ply base flashing. Set primed flanges of metal flashing in full bed of modified bituminous cement material and mechanically fasten through to attachment substrate. | SPEC: 07 52 16.14 DWG. 2.05 - 2.18 | SF | 700 | ||
| A0097 | “Torch-grade” 2 ply Highly reflective (min. initial reflectivity value = 0.78) with 140/138 mil (minimum) SBS modified bituminous cap sheet and 180 mil modified bitumen ply over prepared surface of repair area in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 50 SF. | SPEC: 07 52 16.15 | SF | 50,000 | ||
| A0098 | 1/8" multi-ply, semi-rigid asphaltic roofing substrate board composed of a mineral fortified asphaltic core formed between two asphaltic saturated fiberglass liners recovery board over roof insulation; secure to existing roof substrate by mechanically fastening to the existing roof substrate or per manufacturer's recommendations. Furnish and install 1 SBS 140 mil inter-ply sheet along with 1 SBS 180 mil granular cap sheet. Minimum Quantity per Building per delivery order: 200 SF. | SPEC: 07 52 16.14 and 07 52 16.15 | SF | 20,000 | ||
| A0099 | 1/4" multi-ply, semi-rigid asphaltic roofing substrate board composed of a mineral fortified asphaltic core formed between two asphaltic saturated fiberglass liners recovery board over roof insulation; secure to existing roof substrate by mechanically fastening to the existing roof substrate or per the manufacturer's recommendations. Furnish and install 1 SBS 140 mil inter-ply sheet along with 1 SBS 180 mil granular cap sheet. Minimum Quantity per Building per delivery order: 200 SF. | SPEC: 07 52 16.14 and 07 52 16.15 | SF | 4,000 | ||
| A0100 | 2-ply modified bitumen membrane flashing system consisting of strip flashing and sheet flashing in the angles formed where the roof deck abuts walls, curbs, ventilators, pipes, and other vertical surfaces, and where necessary to make the work watertight. Set primed flanges of metal flashing in full bed of modified bituminous cement material and mechanically fasten through to attachment substrate. | SPEC: 07 52 16.15 DWG. 2.05 - 2.18 | SF | 2500 | ||
| Section 07 54 23 - Thermoplastic Membrane Roofing | ||||||
| A0101 | Fully adhered thermoplastic roof membrane ("Fibertite" or equivalent) over prepared roof deck/substrate, which includes perimeter edge, wall, parapet and expansion joint flashings. Secure sheet to deck/substrate with adhesives for application to insulation or underlayment in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 100 SF. | SPEC: 07 54 23 DWG. 3.01 - 3.15 | SF | 12,500 | ||
| A0102 | Mechanically fastened Thermoplastic roof membrane ("Fibertite" or equivalent) over prepared roof deck/substrate, which includes perimeter edge, wall, parapet and expansion joint flashings. Secure sheet with fasteners for application to insulation or underlayment in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 100 SF. | SPEC: 07 54 23 DWG. 3.01 - 3.15 | SF | 14,000 | ||
| A0103 | Replace roof edge flashing with a fully adhered thermoplastic membrane flashing matching the existing membrane roofing system in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 50 SF. | SPEC: 07 54 23 DWG. 3.01- 3.04 | SF | 500 | ||
| A0104 | Fully adhered thermoplastic membrane flashing at base of curbs, equipment supports, mechanical piping, electrical conduit, and similar roof penetrations (greater than 4" diameter or 4" square); around parapets, curbs and walls as required; matching the existing membrane roofing system in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 50 SF. | SPEC: 07 54 23 DWG. 3.05 - 3.08 | SF | 350 | ||
| A0105 | Fully adhered thermoplastic membrane roof drain flashing in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 50 SF. | SPEC: 07 54 23 DWG. 3.16 and 3.17 | SF | 100 | ||
| A0106 | Fully adhered thermoplastic membrane scupper flashing in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 50 SF. | SPEC: 07 54 23 DWG. 3.18 | SF | 100 | ||
| A0107 | Fully adhered thermoplastic membrane flashing around round penetration, which includes VTR, mechanical piping, electrical and other conduits (less than 4” diameter or 4" square) in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 50 SF. | SPEC: 07 54 23 DWG. 3.19 - 3.21 | SF | 50 | ||
| A0108 | Fully adhered thermoplastic patch to exisitng damaged areas of thermoplastic membrane in accordance with manufacturer’s recommendations. Minimum Quantity per Building per delivery order: 100 SF. | SPEC: 07 54 23 | SF | 500 | ||
| Section 07 62 00 - Sheet Metal Flashing and Trim | ||||||
| A0109 | Stainless steel pitch pan in accordance with manufacturer’s recommendations. Solder all seams to form one continuous piece. Apply grout fill and 2-part pourable urethane sealer – sloped to provide runoff. Provide flashing collar or “umbrella” to penetration to protect the sealer from water intrusion and direct exposure sunlight. Minimum Quantity per Building per delivery order: 1 each at 4-inches deep, up to 8” square. | SPEC: 07 62 00 DWG 1.04 and 1.09 | EA | 10 | ||
| A0110 | Stainless steel sleeve flashing at penetration in accordance with manufacturer’s recommendations. Provide sheet metal ‘umbrella’ flashing to extend over top edge of sleeve. Minimum Quantity per Building per delivery order: 1 each at 8-inches high. | SPEC: 07 62 00 DWG 2.14, 2.17, 2.22, 3.24 and 7.29 | EA | 10 | ||
| A0111 | Stainless steel gravel stop or drip edge fascia flashing assembly with a 4-inch to 6-inch face in accordance with manufacturer's recommendations. Provide continuous cleats of same material. Solder all corner and transition pieces. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 DWG 7.01 and 7.38 | LF | 3,000 | ||
| A0112 | Stainless steel gravel stop or drip edge fascia flashing assembly with a 6-inch to 9-inch face in accordance with manufacturer’s recommendations. Form stiffening rib in face of edge metal where face is greater than 6-inches. Provide continuous cleats of same material. Solder all corner and transition pieces. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 DWG 7.01 | LF | 1,200 | ||
| A0113 | Stainless steel skirt flashing extension or fascia in accordance with manufacturer's recommendations. Secure flashings with continuous cleats of same material. Stagger edge metal and fascia joints. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 DWG 7.01and 7.38 | LF | 250 | ||
| A0114 | Stainless steel gutter assembly (size - 5” X 6”) include metal gutter hangars and straps in accordance with manufacturer’s recommendations. Solder joints in the gutter assembly. Provide expansion joints within the gutter assembly at maximum 40-ft intervals. Slope gutters for positive drainage to downspouts. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 DWG 7.19 - 7.23 | LF | 800 | ||
| A0115 | Stainless steel downspout (size - 4” x 5”), hangars and straps in accordance with manufacturer’s recommendation. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 DWG 7.20 and 7.24 | LF | 200 | ||
| A0116 | Stainless steel scupper assembly with fully soldered seams and joints in accordance with manufacturer’s recommendations. Average scupper size 6” x 8”. Minimum Quantity per Building per delivery order: 1 EA. | SPEC: 07 62 00 DWG 7.25 - 7.28 | EA | 18 | ||
| A0117 | Stainless steel parapet wall coping cap flashing on walls up to 12-inches in width with 4 inch vertical side flanges secudred with continuous cleats. Provide standing seams at joints, continuous cleats along edges, and fully soldered termination and transition pieces in accordance with manufacturer’s recommendations. Cap flashing must be supported by a solid substrate. Slope cap inward to the roof for runoff. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 DWG 7.05 - 7.10 | LF | 400 | ||
| A0118 | Stainless steel surface-mounted reglet in accordance with manufacturer’s recommendations. Provide reglet with slotted holes for fastening to substrate, with neoprene or other suitable weatherproofing washers and with channel for sealant at top edge. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 DWG. 7.33 | LF | 350 | ||
| A0119 | Stainless steel surface-mounted termination bar in accordance with manufacturer’s recommendations. Provide termination bar with slotted holes for fastening to substrate, with neoprene or other suitable weatherproofing washers and with channel for sealant at top edge. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 DWG 7.30 | LF | 900 | ||
| A0120 | (CLIN deleted) | |||||
| A0121 | (CLIN deleted) | |||||
| A0122 | Stainless steel curb cap flashing to close off abandoned HVAC equipment penetration. Provide welded seams and slope for prevention of water intrusion and positive drainage in accordance with manufacturer’s recommendations. Curb size up to 3’ x 3’. | SPEC: 07 62 00 | EA | 15 | ||
| A0123 | Stainless steel ‘L’ Type Flashing with continuous cleat. Minimum Quantity per Building per delivery order: 10 LF. | SPEC: 07 62 00 DWG 4.12 and 7.20 | LF | 500 | ||
| A0124 | Stainless steel ‘L’ Type Flashing without continuous cleat. Minimum Quantity per Building per delivery order: 10 LF. | SPEC: 07 62 00 DWG 4.13 and 7.20 | LF | 500 | ||
| A0125 | Stainless steel ‘J’/'T' Type Flashing with or without continuous receiver. Minimum Quantity per Building per delivery order: 10 LF. | SPEC: 07 62 00 | LF | 500 | ||
| A0126 | Mill finish aluminum gravel stop or drip edge fascia flashing assembly with a 4-inch to 9-inch face in accordance with manufacturer’s recommendations. Form stiffening rib in face of edge metal where face is greater than 6-inches. Provide continuous cleats of same material. Solder all corner and transition pieces. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 DWG 7.01 and 7.38 | LF | 800 | ||
| A0127 | Mill finish aluminum skirt flashing extension or fascia in accordance with manufacturer’s recommendations. Secure flashings with continuous cleats of same material. Stagger edge metal and fascia joints. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 DWG 7.38 | LF | 800 | ||
| A0128 | Mill finish aluminum gutter assembly (size - 5” X 6”) include metal gutter hangars and straps in accordance with manufacturer’s recommendations. Solder joints in the gutter assembly. Provide expansion joints within the gutter assembly at maximum 40-ft intervals. Slope gutters for positive drainage to downspouts. | SPEC: 07 62 00 DWG 7.19 - 7.23 | LF | 600 | ||
| A0129 | Mill finish aluminum downspout (size - 4” x 5”), hangars and straps in accordance with manufacturer’s recommendations. | SPEC: 07 62 00 DWG 7.20 and 7.24 | LF | 500 | ||
| A0130 | Mill finish aluminum parapet wall coping cap flashing on walls. Provide standing seams at joints, continuous cleats along edges, and fully soldered termination and transition pieces in accordance with manufacturer’s recommendations. Cap flashing must be supported by a solid substrate. Slope cap inward to the roof for runoff. Average wall width 12". Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 DWG 7.05 - 7.10 | LF | 300 | ||
| A0131 | Mill finish aluminum scupper assembly with fully soldered seams and joints in accordance with manufacturer’s recommendations. Approximate scupper size 6” x 8” or equivalent size. | SPEC: 07 62 00 DWG 7.25 - 7.28 | EA | 15 | ||
| A0132 | Termination bar with slotted holes for fastening to substrate with neoprene or other suitable weatherproofing washers and with channel for sealant at top edge in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 DWG 7.30 | LF | 500 | ||
| A0133 | Mill finish aluminum expansion joint. Provide termination bar with slotted holes for fastening to substrate, with neoprene or other suitable weatherproofing washers and with channel for sealant at top edge. Average expansion joint 12". Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 DWG 2.11, 7.13 and 7.14 | LF | 200 | ||
| A0134 | Manufactured mill finish aluminum expansion joint assembly. Provide reglet with slotted holes for fastening to substrate, with neoprene or other suitable weatherproofing washers and with channel for sealant at top edge. Average expansion joint 12". Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 DWG. 1.02 | LF | 125 | ||
| A0135 | Mill finish aluminum flashing sleeve at VTR or plumbing vents with cap in accordance with manufacturer’s recommendations. | SPEC: 07 62 00 DWG. 3.20, 3.21 and 3.24 | EA | 20 | ||
| A0136 | Mill finish aluminum curb cap flashing to close off abandoned HVAC equipment penetration. Provide welded seams and slope for prevention of water intrusion and positive drainage in accordance with manufacturer’s recommendations. Up to 3’ x 3’ or equivalent size. | SPEC: 07 62 00 | EA | 10 | ||
| A0137 | Mill finish aluminum valley flashing centrally in roof valleys, free of longitudinal seams, of a width sufficient to extend not less than 8-inches under the roof covering on each side of the valley. | SPEC: 07 62 00 paragraph 3.8 | LF | 50 | ||
| A0138 | Mill finish aluminum stepped flashing where sloping roof surface with shingles abut vertical surfaces. | SPEC: 07 62 00 paragraph 3.9 | LF | 60 | ||
| A0139 | Mill finish aluminum ‘L’ Type Flashing. Provide continuous cleat as required to meet current uplift . Minimum Quantity per Building per delivery order: 10 LF. | SPEC: 07 62 00 DWG 4.12, 4.13 and 7.18 | LF | 60 | ||
| A0140 | Mill finish aluminum ‘J’/'T' Type Flashing with continuous receiver cleat as required to meet current uplift. Minimum Quantity per Building per delivery order: 10 LF. | SPEC: 07 62 00 | LF | 60 | ||
| A0141 | Copper gravel stop or drip edge flashing assembly with a 4-inch to 9-inch face in accordance with manufacturer’s recommendations. Form stiffening rib in face of edge metal where face is greater than 6-inches. Provide continuous cleats of same material. Solder all corner and transition pieces. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 | LF | 400 | ||
| A0142 | Copper skirt flashing extension or fascia in accordance with SMACNA manual. Secure flashings with continuous cleats of same material. Stagger edge metal and fascia joints. Provide 10" section of copper sheet metal bent up to 5 times to form profile and accept cleat retainers. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00 | LF | 400 | ||
| A0143 | Copper gutter assembly (size - 5” X 6” ) include metal gutter hangars and straps in accordance with manufacturer's recommendations. Solder joints in the gutter assembly. Provide expansion joints within the gutter assembly at maximum 40-ft intervals. Slope gutters for positive drainage to downspouts. Minimum Quantity per Building per delivery: 20 LF. | SPEC: 07 62 00; DWG: 7.19 - 7.23 | LF | 600 | ||
| A0144 | Copper downspout (size - 4” x 5”), hangars and straps in accordance with manufacturer's recommendations. Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00; DWG: 7.20 and 7.24 | LF | 500 | ||
| A0145 | Copper parapet wall coping cap flashing on walls. Provide standing seams at joints, continuous cleats along edges, and fully soldered termination and transition pieces in accordance with manufacturer’s recommendations. Cap flashing must be supported by a solid substrate. Slope cap inward to the roof for runoff. Average wall width 12". Minimum Quantity per Building per delivery order: 20 LF. | SPEC: 07 62 00; DWG:7.05 - 7.10 | LF | 175 | ||
| A0146 | Copper valley flashing centrally in roof valleys, free of longitudinal seams, of a width sufficient to extend not less than 8-inches under the roof covering on each side of the valley. | SPEC: 07 62 00 paragraph 3.8 | LF | 100 | ||
| A0147 | Provide and install copper step flashing where sloping roof surface with shingles abut vertical surfaces. | SPEC: 07 62 00 paragraph 3.9 | LF | 100 | ||
| A0148 | Copper 'L' Type Flashing. Provide with continuous cleat as required to meet current uplift requirement. Minimum Quantity per Building per delivery order: 10 LF. | SPEC: 07 62 00 DWG 4.12, 4.13 and 7.18 | LF | 100 | ||
| A0149 | Copper 'J'/ 'T' Type Flashing. with continuous cleat receiver cleat as required to meet current uplift requirement. Minimum Quantity per Building per delivery order: 10 LF. | SPEC: 07 62 00 | LF | 100 | ||
| A0150 | Copper flashing sleeve at VTR or plumbing vents with cap as indicated in accordance with manufacturer’s recommendation. | SPEC: 07 62 00 DWG. 3.20, 3.21 and 3.24 | EA | 25 | ||
| A0151 | Lead sheet metal flashing sleeve at VTR or plumbing vents in accordance with manufacturer’s recommendations. | SPEC: 07 62 00 DWG 7.35 | EA | 25 | ||
| A0152 | Clad aluminum flashing membrane along edge metal for thermoplastic roof system in accordance with manufacturer’s recommendations. | SPEC: 07 62 00 | SF | 400 | ||
| A0153 | Clad pitch pan with aluminum flashing on thermoplastic roof system from 4" x 4" up to 8" x 8", of a width sufficient to extend mimnimum 2" above the roof covering. Minimum Quantity per Building per delivery order: 2 EA. | SPEC: 07 62 00 | EA | 10 | ||
| A0154 | Clad pitch pan with aluminum flashing on thermoplastic roof system from 4"x 4"up to 8"x 8", of a width sufficient to extend min. 4" over the roof covering. Minimum Quantity per Building per delivery order: 2 EA. | SPEC: 07 62 00 | EA | 10 | ||
| A0155 | Clad scuppers with aluminum flashing on thermoplastic roof system up to 12"x 12"x 6" tall sides, of a width sufficient to extend min. 4" over the roof covering. Minimum Quantity per Building per delivery order: 2 EA. | SPEC: 07 62 00 | EA | 10 | ||
| A0156 | Clad scuppers with aluminum flashing on thermoplastic roof system up to 12" wide x 12" deep x 6" tall sides, of a width sufficient to extend min. 4" over the roof covering. Minimum Quantity per Building per delivery order: 1 EA | SPEC: 07 62 00 | EA | 10 | ||
| Section 07 72 00 - Roof Accessories | ||||||
| A0157 | Aluminum roof hatch with insulated double-wall lids and insulated double-wall curb frame with integral deck mounting flange and lid frame counter-flashing. Size 24" x 36" or equivalent size. | SPEC: 07 72 00 | EA | 8 | ||
| A0158 | Stainless steel manufactured low-profile, cylindrical-style gravity ventilator assembly in accordance with manufacturer's recommendations. Size 18" up to 42" diameter or equivalent size. | SPEC: 07 72 00 | EA | 8 | ||
| A0159 | Aluminum (factory manufactured or fabricated) louvered penthouse-style gravity ventilator assembly in accordance with manufacturer’s recommendation. Size up to 20" x 42" or equivalent size. | SPEC: 07 72 00 | EA | 8 | ||
| A0160 | Aluminum manufactured low-profile, louvered penthouse-style gravity ventilator assembly in accordance with manufacturer’s recommendation. Size larger than 20" x 42". | SPEC: 07 72 01 | SF | 40 |