AGE Data 5 May 07 to 5 May 09.xlsx

XLSX spreadsheet 115 KB Posted

Attached to
Transient Alert Services and AGE Maintenance
Solicitation number
FA2517-09-R-6015
Issued by

About this file

AGE Data 5 May 07 to 5 May 09

View the file

Other files

File Type Posted
Aircraft workload Jan 07 to May 08.xls XLS spreadsheet
AIRCRAFT LOG-Jun 08 to May 09.rtf RTF text file
FA2517-09-R-6015-0002.doc DOC document
Questions regarding RFP_Amendment 0002.doc DOC document
Technical Questions_Amendment 0002.doc DOC document
Workload by shift.xls XLS spreadsheet
TA Reacq Site visit agenda.doc DOC document
FA2517-09-R-6015-0001.doc DOC document
AFI21-118.pdf PDF
WORKLOAD ESTIMATES.docx DOCX document
AFMAN23-110V2PT2CH11.pdf PDF
00-20-1.pdf PDF
Final 2008 Hazardous Waste Management Plan.pdf PDF
00-35D-54.pdf PDF
AFMAN23-110V2PT13CH6.pdf PDF
AFI31-204.pdf PDF
1-1A-15 Chapter 11-12.pdf PDF
AFI11-218.pdf PDF
1-1A-15 Chapter 23-24-25.pdf PDF
1-1A-15 Chapter 20-21-22.pdf PDF
AFOSHSTD91-100.pdf PDF
AFMAN23-110V2PT13CH3.pdf PDF
AFI21-101_21SWSUP1.pdf PDF
AFMAN23-110V2PT13CH2.pdf PDF
1-1A-15 Index.pdf PDF
AFMAN23-110V2PT2CH22.pdf PDF
GOVERNMENT FURNISHED EQUIPMENT and Vehicles.doc DOC document
Solicitation_FA251709R6015.pdf PDF
1-1A-15 Chapter 4-5-6.pdf PDF
1-1A-15 Chapter 7-8-9-10.pdf PDF
AFI32-7066.pdf PDF
AFI23-302.pdf PDF
AFMAN23-110V2PT13CH1.pdf PDF
1-1A-15 Table of Contents.pdf PDF
1-1A-15 Chapter 15a.pdf PDF
GROUND EQUIPMENT PERIODIC INSPECTION.doc DOC document
1-1A-15 Chapter 15b.pdf PDF
AFMAN23-110V2PT13CH4.pdf PDF
1-1A-15 Chapter 1-2-3.pdf PDF
1-1A-15 Chapter 13-14.pdf PDF
AFI10-701.pdf PDF
AFI24-301.pdf PDF
00-5-1.pdf PDF
1-1A-15 Chapter 26.pdf PDF
AFMAN23-110V2PT13CH7.pdf PDF
AFI23-204.pdf PDF
AFI32-7086.pdf PDF
Final 2008 Spill Prevention, Control, and Countermeasure Plan.pdf PDF
AFI21-101.pdf PDF
AFMAN23-110V2PT13CH5.pdf PDF
Show 40 more

Latest 50 of 64 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCH-UNSCH Jobs

Date Range5 May 07 to 5 May 09
Total
UnscheduledB85
PeriodicP377
INSPS69
Time COMT8
AC01NGHB-1B-2B-4B-5
Count of TMCount of TMCount of TMCount of TMCount of TMCount of TM
TMTotalTMTotalTMTotalTMTotalTMTotalTMTotal
B1B12P12P9B1B3
P4P32S4S2P18P12
S3T5(blank)(blank)S3S2
(blank)(blank)Grand Total16Grand Total11(blank)(blank)
Grand Total8Grand Total49Grand Total22Grand Total17
C-1SkateFuel BowserB809DM32A 60AM32A 95
Count of TMCount of TMCount of TMCount of TMCount of TMCount of TM
TMTotalTMTotalTMTotalTMTotalTMTotalTMTotal
B1P4B2B25B6B9
P4S3P16P51P17P15
(blank)(blank)(blank)S1(blank)(blank)
Grand Total5Grand Total7Grand Total18(blank)Grand Total23Grand Total24
Grand Total77
GoxHYDTTU-2285 Ton JackLoad BankLadder
Count of TMCount of TMCount of TMCount of TMCount of TMCount of TM
TMTotalTMTotalTMTotalTMTotalTMTotalTMTotal
B1P6B1P4P16B4
P6S1P10S2S1P18
S9(blank)(blank)(blank)(blank)S1
(blank)Grand Total7Grand Total11Grand Total6Grand Total17(blank)
Grand Total16Grand Total23
Lox CartFL-1DNIT Cart 8 BTLNIT Cart S/GOIL Cart 7808OIL Cart 23699
Count of TMCount of TMCount of TMCount of TMCount of TMCount of TM
TMTotalTMTotalTMTotalTMTotalTMTotalTMTotal
B4B1B2B4B1B2
P10P52P7P6P5P5
S19(blank)S9S3S1S1
(blank)Grand Total53(blank)T3(blank)(blank)
Grand Total33Grand Total18(blank)Grand Total7Grand Total8
Grand Total16
Tow T-38T-37C-12TB07TB08Tow C-17
Count of TMCount of TMCount of TMCount of TMCount of TMCount of TM
TMTotalTMTotalTMTotalTMTotalTMTotalTMTotal
P8B1P2B1B1B1
(blank)P7(blank)(blank)P5P4
Grand Total8(blank)Grand Total2Grand Total1S1S1
Grand Total8(blank)(blank)
Grand Total7Grand Total6
F-2 Trailer
Count of TM
TMTotal
B1
P12
S2
(blank)
Grand Total15

A M32C-10

Eqp-IDEventWCE NBRWorkcenterSRDDiscrepancy NarrDDRTMCPWUC/LCNATWDHMMCCUPSTART TimeDATESTOP TimeHRSCSCat LaborUSER-IdWCE NarrativeCorrective Actioneg_NOINSHOPEvt Comp
GAC010726100011ASERIWLSPHASE 1 FREQ 000365D DUE 20072621P03307H0109000726115006.016PN10ZXPEP.E. C/W.NOESPINOZA18 SEP 07
GAC010806500021ASERIWLSPHASE II FREQ 000365D DUE 20080801S04114H0012000806915003.016PN10ZX1 YR SPECIALSTRATED INSP. LOOKED UNIT OVER PUT IN WASH RACK AND WASHED.NOESPINOZA10 MAR 08
GAC010806500021ASERIWLSPHASE II FREQ 000365D DUE 20080802S04114H0107000807011304.516PN10ZX1 YR SPECIALCOMPLETED WORK CARDS RAN UNIT OPS CHECKED GOOD. P.E. C/W.NOESPINOZA10 MAR 08
GAC010824800011ASERIWLSPHASE 1 FREQ 000365D DUE 20082621P03307H0013000824815002.016PN10ZXPELOOKED UNIT OVER AND WASHED.NOESPINOZA09 SEP 08
GAC010824800011ASERIWLSPHASE 1 FREQ 000365D DUE 20082622P03307H0009000825214155.316PN10ZXPECOMPLETED ALL WORK CARDS EXCEPT FOR OPS CHECKS.NOESPINOZA09 SEP 08
GAC010824800011ASERIWLSPHASE 1 FREQ 000365D DUE 20082623P03307H0108000825308450.816PN10ZXPERAN UNIT OPS CHECKED GOOD P.E. C/W.NOESPINOZA09 SEP 08
GAC010903540001ASERIWLSUNIT DUE FULL PAINT.1BAGEPAGF23B0111000902913002.016PN10ZXUNIT DUE FULL PAINT.RECEIVED UNIT FROM PAINT SHOP. INSTALLED ALL REQUIRED MARKIN GS AND REFLECTIVE TAPE RAN UNIT OPS CHECKED GOOD.NOESPINOZA29 JAN 09
GAC010906800011ASERIWLSPHASE II FREQ 000365D DUE 20090791S04114H0109000906915006.016PN10ZX1 YR SPECIALP.E. C/W.NOESPINOZA10 MAR 09

NGH

Eqp-IDEventWCE NBRWorkcenterSRDDiscrepancy NarrDDRTMCPWUC/LCNATWDHMMCCUPSTART TimeDATESTOP TimeHRSCSCat LaborUSER-IdWCE NarrativeCorrective Actioneg_NOINSHOPEvt Comp
GNG010722100011ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20072251P03309H0111000721915004.016PN10ZXPERFORM PHASE II INSPECTION.COMPLETED ALL WORK CARDS EXCEPT FOR OPS CHECKS.NOESPINOZA07 AUG 07
GNG010803600011ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20080461P03307H0113000803815002.016PN10ZXPERFORM PHASE I INSPECTION.REPLACED OIL AND FILTER WASHED UNIT LUBED AND STARTED OPS CHECK WOULDN'T PASS SMOKE TEST.NOESPINOZA07 FEB 08
GNG010821800011ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20082251P03309H0109000821915006.016PN10ZXPERFORM PHASE II INSPECTION.P.E. C/W.NOESPINOZA06 AUG 08
GNG010822040001ASERIG3FELECTRODE MOUNTING BLOCK BROKE.1BAGEAAGF07A0111000827612301.516PN10ZXELECTRODE MOUNTING BLOCK BROKE.REPLACED ELECTRODE MOUNT AND INSTALLED NOZZLE IN UNIT RAN AN D PERFORMED SMOKE CHECKGOOD UNIT OPS CHECKED GOOD.NOPN09JR02 OCT 08
GNG010831540021ASERIG3FUNIT DUE FOR FULL PAINT.1BAGEAAGF23B0107000832511004.016PN10ZXUNIT DUE FOR FULL PAINT.GOT UNIT BACK FROM PAINT SHOT INSTALLED MARKING AND REFLECTI VE TAPE RAN UNIT OPS CHECKED GOOD.NOPN09JR20 NOV 08
GNG010903600021ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20090451P03307H0011000904115004.016PN10ZXPERFORM PHASE I INSPECTION.WASHED AND STARTED TO LUBE.NOESPINOZA12 FEB 09
GNG010903600021ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20090452P03307H0109000904312003.016PN10ZXPERFORM PHASE I INSPECTION.COMPLETED WORK CARDS RAN UNIT AND PERFORMED SMOKE AND CO2 CHECKS GOOD UNIT OPS CHECKED GOOD P.E. C/W.NOESPINOZA12 FEB 09
GNG010908900011ASERIG3FINSPECT ALTERNATORS FOR CHAFFING AND CORRECT TCTO NBR 35E7-2-11-502 GRND DATE= 091601T3507780D0107000907109002.016PN10ZXINSPECT ALTERNATOR FOR CHAFFING AND CORRECTINSPECT ALTERNATOR FOR CHAFFING AND CORRECTNO12 MAR 09
GNG020722100021ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20072291P03309H0007000722215008.016PN10ZXPERFORM PHASE II INSPECTION.COMPLETED ALL WORK CARDS EXCEPT FOR RUNNING OPS CHECKW AND INSPECTING DUCTS.NOESPINOZA13 AUG 07
GNG020722100021ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20072292P03309H0107000722509002.016PN10ZXPERFORM PHASE II INSPECTION.INSPECTED DUCTS AND RAN UNIT OPS CHECKED GOOD. P.E. C/W.NOESPINOZA13 AUG 07
GNG020803700011ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20080461P03307H0107000803812005.016PN10ZXPERFORM PHASE I INSPECTION.P.E. C/W.NOESPINOZA07 FEB 08
GNG020809040001ASERIG3FDEAD BATTERY.1BAGEAALF16A0112000809313301.516PN10ZXDEAD BATTERY.RECHARGED BATTERY RAN UNIT OPS CHECKED GOOD.NOESPINOZA02 APR 08
GNG020821900011ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20082291P03309H0107000822014007.016PN10ZXPERFORM PHASE II INSPECTION.P.E. C/W.NOESPINOZA07 AUG 08
GNG020833040001ASERIG3FUNIT DUE FULL PAINT.1BAGEAAGF23B0110300836412001.516PN10ZXUNIT DUE FULL PAINT.GOT UNIT BACK FROM PAINT SHOP, INSTALLED ALL MARKINGS AND RE FLECTIVE TAPE. RAN UNIT OPS CHECKED GOOD.NOESPINOZA29 DEC 08
GNG020903700011ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20090451P03307H0013000904015002.016PN10ZXPERFORM PHASE I INSPECTION.WASHED UNIT AND STARTED TO LUBE.NOESPINOZA12 FEB 09
GNG020903700011ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20090452P03307H0007000904111004.016PN10ZXPERFORM PHASE I INSPECTION.WASHED UNIT AND COMPLETED ALL WORK CARDS EXCEPT FOR OPS CHECKS.NOESPINOZA12 FEB 09
GNG020903700011ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20090453P03307H0107000904309002.016PN10ZXPERFORM PHASE I INSPECTION.RAN UNIT PERFORMED SMOKE AND CO2 CHECKS GOOD UNIT OPS CHECKED GOOD P.E. C/W.NOESPINOZA12 FEB 09
GNG020909000011ASERIG3FINSPECT ALTERNATORS FOR CHAFFING AND CORRECT TCTO NBR 35E7-2-11-502 GRND DATE= 091601T3507780D0109000907111002.016PN10ZXINSPECT ALTERNATOR FOR CHAFFING AND CORRECTINSPECT ALTERNATOR FOR CHAFFING AND CORRECTNO12 MAR 09
GNG030716300011ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20071611P03307H0109000716315006.016PN10ZXPERFORM PHASE I INSPECTION.P.E. C/W.NOESPINOZA12 JUN 07
GNG030733700011ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20073441P03309H0007000733811004.016PN10ZXPERFORM PHASE II INSPECTION.REPLACED OIL, OIL FILTER, FUEL FILTER, AND AIR FILTER. CLEANED BURNER NOZZLE AND COMBUSTER SECTION AND WASHED.NOESPINOZA06 DEC 07
GNG030733700011ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20073442P03309H0107000734012005.016PN10ZXPERFORM PHASE II INSPECTION.P.E. C/W.NOESPINOZA06 DEC 07
GNG030816300011ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20081611P03307H0010000816115005.016PN10ZXPERFORM PHASE I INSPECTION.REPLACED OIL AND OIL FILTER. PUT IN WASH RACK AND WASHED COMPLETED ALL WORK CARDS EXCEPT FOR OPS CHECKS.NOESPINOZA10 JUN 08
GNG030816300011ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20081612P03307H0107000816210003.016PN10ZXPERFORM PHASE I INSPECTION.RAN UNIT CO2 AND SMOKE CHECKS WERE GOOD. FOUND TEMP DISPLAY WAS NOT WORKING. REPLACED DISPLAY AND UNIT OPS CHECKED GOOD.NOESPINOZA10 JUN 08
GNG030833140011ASERIG3FUNIT DUE FULL PAINT.1BAGEAAGF23B0112000836413301.516PN10ZXUNIT DUE FULL PAINT.GOT UNIT BACK FROM PAINT SHOP, INSTALLED ALL MARKINGS AND RE FLECTIVE TAPE. RAN UNIT OPS CHECKED GOOD.NOESPINOZA29 DEC 08
GNG030834300011ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20083441P03309H0107000836514307.516PN10ZXPERFORM PHASE II INSPECTION.P.E. C/W.NOESPINOZA30 DEC 08
GNG030909100011ASERIG3FINSPECT ALTERNATORS FOR CHAFFING AND CORRECT TCTO NBR 35E7-2-11-502 GRND DATE= 091601T3507780D0107000909109002.016PN10ZXINSPECT ALTERNATOR FOR CHAFFING AND CORRECTINSPECT ALTERNATOR FOR CHAFFING AND CORRECTNO01 APR 09
GNG030909140011ASERIG3FBURNER CONSTANTLY MISFIRES.1BAGEAALF25A0107000909510003.016PN10ZXBURNER CONSTANTLY MISFIRES.CLEAND AND ADJUSTED FUEL NOZZLE. BLED FUEL SYSTEM RAN UNIT O PS CHECKED GOOD.NO05 APR 09
GNG040717800011ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20071811P03307H0111000717815004.016PN10ZXPERFORM PHASE I INSPECTION.FERFORMED ALL WORK CARDS EXCEPT FOR OPS CHECK.NOESPINOZA27 JUN 07
GNG040734600011ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20073641P03309H0007000734515008.016PN10ZXPERFORM PHASE II INSPECTION.COMPLETED ALL WORK CARD EXCEPT FOR REPACKING BEARINGS AND OPS CHECKS.NOESPINOZA14 DEC 07
GNG040734600011ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20073642P03309H0107000734812005.016PN10ZXPERFORM PHASE II INSPECTION.REPACKED WHEEL BEARING RAN AND ADJUSTED SMOKE CHECK UNIT OPS CHECK GOOD. P.E. C/W.NOESPINOZA14 DEC 07
GNG040816900031ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20081811P03307H0107000818315008.016PN10ZXPERFORM PHASE I INSPECTION.P.E. C/W.NOESPINOZA01 JUL 08
GNG040835800011ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20083641P03309H0011000835715004.016PN10ZXPERFORM PHASE II INSPECTION.REPLACED OIL FILTER, OIL FUEL FILTER, AND AIR FILTER. PUT IN WASHRACK AND WASHED.NOESPINOZA30 DEC 08
GNG040833040011ASERIG3FUNIT DUE FULL PAINT.1BAGEAAGF23B0113300836415001.516PN10ZXUNIT DUE FULL PAINT.GOT UNIT BACK FROM PAINT SHOP, INSTALLED ALL MARKINGS AND RE FLECTIVE TAPE. RAN UNIT OPS CHECKED GOOD.NOESPINOZA29 DEC 08
GNG040835800011ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20083642P03309H0114000836517303.516PN10ZXPERFORM PHASE II INSPECTION.COMPLETED ALL WORK CARDS RAN UNIT PERFORMED CO2 CHECK AND SMOKE CHECK UNIT OPS CHECK GOOD P.E. C/W.NOESPINOZA30 DEC 08
GNG040909200011ASERIG3FINSPECT ALTERNATORS FOR CHAFFING AND CORRECT TCTO NBR 35E7-2-11-502 GRND DATE= 091601T3507780D0112000909014002.016PN10ZXINSPECT ALTERNATOR FOR CHAFFING AND CORRECTINSPECT ALTERNATOR FOR CHAFFING AND CORRECTNO31 MAR 09
GNG050731800011ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20073231P03309H0013000731915002.016PN10ZXPERFORM PHASE II INSPECTION.REPLACED FILTERS AND OIL. PUT IN WASH RACK AND WASHED.NOESPINOZA16 NOV 07
GNG050731800011ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20073232P03309H0107000732010003.016PN10ZXPERFORM PHASE II INSPECTION.COMPLETED WORK CARDS. RAN UNIT DID CO2 AND SMOKE TESTS GOOD UNIT OPS CHECK GOOD. P.E. C/W.NOESPINOZA16 NOV 07
GNG050733740001ASERIG3FEMERGENCY ENGINE SHUT OFF SWITCH STICKS.1BAGEAAGF12A0107000735108301.516PN10ZXEMERGENCY ENGINE SHUT OFF SWITCH STICKS.REPLACED EMERGENCY SHUT OFF SWITCH. RAN UNIT OPS CHECKED GOO D.NO17 DEC 07
GNG050814000011ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20081391P03307H0010000814213303.516PN10ZXPERFORM PHASE I INSPECTION.REPLACED OIL AND OIL FILTER PUT ON WASH RACK AND WASHED.NOESPINOZA22 MAY 08
GNG050814000011ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20081392P03307H0107000814310153.316PN10ZXPERFORM PHASE I INSPECTION.LUBED AND LOOKED UNIT OVER. RAN AND PERFORMED SMOKE CHACK AND CO2 CHECK UNIT OPS CHECKED GOOD. P.E. C/W.NOESPINOZA22 MAY 08
GNG050821540001ASERIG3FCONSTANTLY GET BURNER FAILURE.1BAGEAAGF23B0113000821715002.016PN10ZXCONSTANTLY GET BURNER FAILURE.CLEANED FLAME SENSOR AND FUEL SPRAY NOZZLE RAN UNIT OPS CHEC KED GOOD.NO04 AUG 08
GNG050832400011ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20083231P03309H0007000835915008.016PN10ZXPERFORM PHASE II INSPECTION.WASHED UNIT REPLACED OIL FILTER, OIL FUEL FILTER AND AIR FILTER. CHECKED FUEL LOW POINT AND STARTED TO LUBE.NOESPINOZA29 DEC 08
GNG050833040021ASERIG3FUNIT DUE FULL PAINT.1BAGEAAGF23B0109000836410301.516PN10ZXUNIT DUE FULL PAINT.GOT UNIT BACK FROM PAINT SHOP. INSTALLED ALL MARKINGS AND RE FLECTIVE TAPE. RAN UNIT OPS CHECKED GOOD.NOESPINOZA29 DEC 08
GNG050832400011ASERIG3FPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20083232P03309H0107000836409002.016PN10ZXPERFORM PHASE II INSPECTION.COMPLETED WORK CARDS. RAN UNIT OPS CHECKED GOOD. P.E. C/W.NOESPINOZA29 DEC 08
GNG050909140021ASERIG3FTEMP. DISPLAY MISSING PARTS OF NUMBERS.1BAGEAAGF16A0111000909112001.016PN10ZXTEMP. DISPLAY MISSING PARTS OF NUMBERS.REPLACED DISPLAY MODULE RAN UNIT OPS CHECKED GOOD.NO01 APR 09
GNG050909140021ASERIG3FTEMP. DISPLAY MISSING PARTS OF NUMBERS.2BAGEAAGF23B0112000909114302.516PN10ZXTEMP. DISPLAY MISSING PARTS OF NUMBERS.CLEANED FLAME SENSOR AND NOZZLE RAN UNIT AND BLED FUEL SYSTE M UNIT OPS CHECKED GOOD.NO01 APR 09
GNG050909300011ASERIG3FINSPECT ALTERNATORS FOR CHAFFING AND CORRECT TCTO NBR 35E7-2-11-502 GRND DATE= 091601T3507780D0109000909111002.016PN10ZXINSPECT ALTERNATOR FOR CHAFFING AND CORRECTINSPECT ALTERNATOR FOR CHAFFING AND CORRECTNO01 APR 09
GNG050913800011ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20091381P03307H0011000913815004.016PN10ZXPERFORM PHASE I INSPECTION.COMPLETED ALL WORK CARDS EXCEPT FOR OPS CHECKS.NOPN09JR22 MAY 09
GNG050913800011ASERIG3FPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20091382P03307H0111000914212451.816PN10ZXPERFORM PHASE I INSPECTION.RAN UNIT CO2 CHECK WAS GOOD SMOKE TEST WAS BAD. CLEANED FUEL INJECTOR NOW OPS CHECKED GOOD P.E. C/W.NOPN09JR22 MAY 09
Unscheduled

B-1

Eqp-IDEventWCE NBRWorkcenterSRDDiscrepancy NarrDDRTMCPWUC/LCNATWDHMMCCUPSTART TimeDATESTOP TimeHRSCSCat LaborUSER-IdWCE NarrativeCorrective Actioneg_NOINSHOPEvt Comp
GB1010726900011ASERIWEEPERIODIC 180 DAY FREQ 000182D DUE 20072751P03307H0107000727013156.316PN10ZXPEP.E. C/W.NOESPINOZA27 SEP 07
GB1010809100021ASERIWEESPECIAL 2 YEARS. FREQ 000730D DUE 20080991S04114H0107000809212005.016PN10ZXSPECIAL TWO YEAR INSPECTION DUE.REPACKED WHEEL BEARINGS REPLACED INNER SEALS AND SEALED CAPS.NOESPINOZA01 APR 08
GB1010809100022ASERIWEESPECIAL 2 YEARS. FREQ 000730D DUE 20080991S04114H0112000809215003.016PN10ZXSPECIAL TWO YEAR INSPECTION DUE.CHECKED FLUID IN RESOVOIR FOR DIRT AND WATER LOOKED GOOD SERVICED UNIT OPS CHECK GOOD.NOESPINOZA01 APR 08
GB1010809100011ASERIWEEPERIODIC 180 DAY FREQ 000182D DUE 20080921P03307H0106000809309003.016PN10ZXPEP.E. C/W.NOESPINOZA02 APR 08
GB1010826000011ASERIWEEPERIODIC 180 DAY FREQ 000182D DUE 20082741P03307H0008000826015007.016PN10ZXPEWASHED UNIT LOOKED OVER AND STARTED TO LUBE FOUND TIRE LEAKING AND REPLACED TUBE.NOESPINOZA17 SEP 08
GB1010826000011ASERIWEEPERIODIC 180 DAY FREQ 000182D DUE 20082742P03307H0107000826108001.016PN10ZXPEINSTALLED TIRE, COMPLETED WORK CARDS, AND OPS CHECKED. P.E. C/W.NOESPINOZA17 SEP 08
GB1010907100021ASERIWEEPERIODIC 180 DAY FREQ 000182D DUE 20090901P03307H0007000907511004.016PN10ZXPELOOKED STAND OVER PUT IN WASH RACK AND WASHED. STARTED TO LUBE.NOESPINOZA17 MAR 09
GB1010907100021ASERIWEEPERIODIC 180 DAY FREQ 000182D DUE 20090902P03307H0109000907611002.016PN10ZXPEFINISHED LUBING STAND OPS CHECKED GOOD P.E. C/W.NOESPINOZA17 MAR 09
GB1020722500011ASERIWEEPERIODIC 180 DAY FREQ 000182D DUE 20072251P03307H0009000722512453.816PN10ZXPELOOKED UNIT OVER PUT IN WASH RACK AND WASHED.NOESPINOZA14 AUG 07
GB1020722500011ASERIWEEPERIODIC 180 DAY FREQ 000182D DUE 20072252P03307H0107000722609002.016PN10ZXPEP.E. C/W.NOESPINOZA14 AUG 07
GB1020803500011ASERIWEEPERIODIC 180 DAY FREQ 000182D DUE 20080421P03307H0109300804415005.516PN10ZXPEP.E. C/W.NOESPINOZA13 FEB 08
GB1020821400021ASERIWEEPERIODIC 180 DAY FREQ 000182D DUE 20082241P03307H0010300821412001.516PN10ZXPELOOKED UNIT OVER PUT IN WASH RACK AND WASHED.NOESPINOZA06 AUG 08
GB1020821400021ASERIWEEPERIODIC 180 DAY FREQ 000182D DUE 20082242P03307H0107000821909302.516PN10ZXPEP.E. C/W.NOESPINOZA06 AUG 08
GB1020821400031ASERIWEESPECIAL 2 YEARS. FREQ 000730D DUE 20082281S04114H0109000821910001.016PN10ZXSPECIAL TWO YEAR INSPECTION DUE.REPACKED WHEEL BEARINGS.NOESPINOZA06 AUG 08
GB1020821400032ASERIWEESPECIAL 2 YEARS. FREQ 000730D DUE 20082281S04114H0110000821911001.016PN10ZXSPECIAL TWO YEAR INSPECTION DUE.TOOK SAMPLE OF FLUID NO CONTAMINATION NOTED SERVICED FLUID.NOESPINOZA06 AUG 08
GB1020903400011ASERIWEEPERIODIC 180 DAY FREQ 000182D DUE 20090401P03307H0107000904013006.016PN10ZXPEP.E. C/W.NOESPINOZA09 FEB 09

B-2

Eqp-IDEventWCE NBRWorkcenterSRDDiscrepancy NarrDDRTMCPWUC/LCNATWDHMMCCUPSTART TimeDATESTOP TimeHRSCSCat LaborUSER-IdWCE NarrativeCorrective Actioneg_NOINSHOPEvt Comp
GB2010732400021ASERIWMFPERIODIC 180 DAY FREQ 000182D DUE 20073341P03307H0007000732311004.016PN10ZX180 DAY PERIODIC DUEWASHED UNIT AND STARTED TO LUBE.NOESPINOZA20 NOV 07
GB2010732400021ASERIWMFPERIODIC 180 DAY FREQ 000182D DUE 20073342P03307H0107000732411004.016PN10ZX180 DAY PERIODIC DUEP.E. C/W.NOESPINOZA20 NOV 07
GB2010815400011ASERIWMFPERIODIC 180 DAY FREQ 000182D DUE 20081511P03307H0012000815415003.016PN10ZX180 DAY PERIODIC DUEWASHED STAND STARTED TO LUBE AND LOOK OVER.NOESPINOZA03 JUN 08
GB2010815400011ASERIWMFPERIODIC 180 DAY FREQ 000182D DUE 20081512P03307H0108000815511303.516PN10ZX180 DAY PERIODIC DUEFINISHED LUBE AND LOOKING UNIT OVER OPS CHECKED GOOD P.E. C/W.NOESPINOZA03 JUN 08
GB2010815400021ASERIWMFSPECIAL FLUID CHECK FREQ 000365D DUE 20081531S04114H0111300815512301.016PN10ZXANNUAL SPECIAL FLUID INSPECTIONDRAINED SMALL AMOUNT OF FLUID TO CHECK FOR DIRT AND WATER FLUID LOOKED GOOD TOP RES. OFF FLUID CHECK C/W.NOESPINOZA03 JUN 08
GB2010832900021ASERIWMFPERIODIC 180 DAY FREQ 000182D DUE 20083331P03307H0011000833615004.016PN10ZX180 DAY PERIODIC DUEWASHED UNIT STARTED TO LUBE AND LOOK OVER.NOPN09JR02 DEC 08
GB2010832900021ASERIWMFPERIODIC 180 DAY FREQ 000182D DUE 20083332P03307H0107000833709002.016PN10ZX180 DAY PERIODIC DUEFINISHED LUBE AND LOOKED OVER OPS CHECKED GOOD. P.E. C/W.NOPN09JR02 DEC 08
GB2010914800011ASERIWMFPERIODIC 180 DAY FREQ 000182D DUE 20091491P03307H0111000915215004.016PN10ZX180 DAY PERIODIC DUEP.E. C/W.NOESPINOZA01 JUN 09
GB2010914800021ASERIWMFSPECIAL FLUID CHECK FREQ 000365D DUE 20091521S04114H0107000915509002.016PN10ZXANNUAL SPECIAL FLUID INSPECTIONFLUID CHECK C/W.NOESPINOZA04 JUN 09
GB2020912700011ASERIWMFPERIODIC 180 DAY FREQ 000182D DUE 20091411P03307H0015300912617001.516PN10ZX180 DAY PERIODIC DUEWASHED STANED AND STARTED TO LUBE.NOESPINOZA07 MAY 09
GB2020912700011ASERIWMFPERIODIC 180 DAY FREQ 000182D DUE 20091412P03307H0107000912709302.516PN10ZX180 DAY PERIODIC DUEP.E. C/W.NOESPINOZA07 MAY 09

B-4

Eqp-IDEventWCE NBRWorkcenterSRDDiscrepancy NarrDDRTMCPWUC/LCNATWDHMMCCUPSTART TimeDATESTOP TimeHRSCSCat LaborUSER-IdWCE NarrativeCorrective Actioneg_NOINSHOPEvt Comp
GB4010717100011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20071761P03307H0107000717112005.016PN10ZX180 DAY PEP.E. C/W.NOPN09JR20 JUN 07
GB4010735200011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20073581P03307H0007000735209002.016PN10ZX180 DAY PELOOKED UNIT PVER PUT IN WASH RACK AND WASHED.NOESPINOZA19 DEC 07
GB4010735200011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20073582P03307H0107000735309002.016PN10ZX180 DAY PELUBED AND GAVE UNIT FINAL LOOK OVER. P.E. C/W.NOESPINOZA19 DEC 07
GB4010816900021ASERIWECSPECIAL 730 DAY FREQ 000730D DUE 20081811S04114H0111200816815003.716PN10ZX720 DAY INSPECTIONP.E. C/W.NOESPINOZA16 JUN 08
GB4010816900011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20081751P03307H0107000817011254.416PN10ZX180 DAY PEP.E. C/W.NOESPINOZA18 JUN 08
GB4010835200011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20083571P03307H0007000835711004.016PN10ZX180 DAY PEWASHED UNIT REPLACED GROUND WIRE AND STARTED TO LUBE.NOPN09JR22 DEC 08
GB4010835200011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20083572P03307H0111000835713152.316PN10ZX180 DAY PECOMPLETED WORKCARDS UNIT OPS CHECKED GOOD. P.E. C/W.NOPN09JR22 DEC 08
GB4020722800041ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20072391P03307H0107000722808301.516PN10ZX180 DAY PEP.E. C/W.NOESPINOZA16 AUG 07
GB4020722800051ASERIWECSPECIAL 730 DAY FREQ 000730D DUE 20072431S04114H0108300722810001.516PN10ZX720 DAY INSPECTIONREPACKED BEARINGS.NOESPINOZA16 AUG 07
GB4020804600011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20080561P03307H0013000805015002.016PN10ZX180 DAY PEWASHED UNIT STARTED TO LUBE AND LOOK UNIT OVER.NOESPINOZA20 FEB 08
GB4020804600011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20080562P03307H0107000805109002.016PN10ZX180 DAY PEP.E. C/W.NOESPINOZA20 FEB 08
GB4020823400011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20082381P03307H0013000823115002.016PN10ZX180 DAY PELOOKED UNIT OVER PUT IN WASH RACK AND WASHED.NOPN09JR20 AUG 08
GB4020823400011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20082382P03307H0110300823314304.016PN10ZX180 DAY PEP.E. C/W.NOPN09JR20 AUG 08
GB4020905140001ASERIWECUNIT PREPPED FOR PAINT.1BAGENMGF23B0107000912411004.016PN10ZXUNIT PREPPED FOR PAINT.RECEIVED FROM PAINT. INSTALLED ALL REQUIRED MARKINGS AND REF LECTIVE TAPE.NOESPINOZA04 MAY 09
GB4020907500011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20090541P03307H0107000912511004.016PN10ZX180 DAY PEP.E. C/W.NOESPINOZA05 MAY 09
GB4030731100011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20073181P03307H0107000731715008.016PN10ZX180 DAY PESTARTED P.E. WASHED UNIT STARTED TO LUBE.NOESPINOZA13 NOV 07
GB4030813500011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20081351P03307H0011000813415004.016PN10ZX180 DAY PESTARTED INSPECTION WASHED UNIT STARTED TO LUBE.NOESPINOZA14 MAY 08
GB4030813500011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20081352P03307H0107000813510003.016PN10ZX180 DAY PEP.E. C/W.NOESPINOZA14 MAY 08
GB4030831700011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20083171P03307H0014000831715001.016PN10ZX180 DAY PELOOKED UNIT OVER PUT IN WASH RACK AND WASHED.NOESPINOZA19 NOV 08
GB4030831700011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20083172P03307H0107000832415008.016PN10ZX180 DAY PEP.E. C/W.NOESPINOZA19 NOV 08
GB4030913300011ASERIWECPERIODIC 6 MONTHS. FREQ 000182D DUE 20091331P03307H0108000913111003.016PN10ZX180 DAY PEP.E. C/W.NOESPINOZA11 MAY 09
GB4030913300021ASERIWECSPECIAL 730 DAY FREQ 000730D DUE 20091361S04114H0111000913114303.516PN10ZX720 DAY INSPECTIONREPACKED WHEEL BEARINGS AND INSPECTED FLUID.NOESPINOZA11 MAY 09

B-5

Eqp-IDEventWCE NBRWorkcenterSRD1Discrepancy NarrDDRTMCPWUC/LCNATWDHMMCCUPSTART TimeDATESTOP TimeHRSCSCat LaborUSER-IdWCE NarrativeCorrective Actioneg_NOINSHOPEvt Comp
GB5010729240001ASERIWEDLEFT FORWARD LEG AND MOUNT HOLE CRACKED.1BAGENMGF19A0107000729215008.016PN10ZXLEFT FORWARD LEG AND MOUNT HOLE CRACKED.REMOVED LEG TO GET CRACK REPAIRED FOUND MOUNT HOLE ALSO CRAC KED. REINSTALLED LEG AND TOOK TO 302ND FOR REPAIR. AFTER 302 ND WELDED CRACKS TOWED UNTI BACK AND TOUCHED UP PAINT.NO19 OCT 07
GB5010729200011ASERIWEDPERIODIC 6 MONTHS. FREQ 000182D DUE 20073061P03307H0007000729510003.016PN10ZXPEREPLACED WORN WHEEL AND LOOKED UNIT OVER. PUT IN WASH RACK AND WASHED.NOESPINOZA29 OCT 07
GB5010729200011ASERIWEDPERIODIC 6 MONTHS. FREQ 000182D DUE 20073062P03307H0107000730215008.016PN10ZXPEP.E. C/W.NOESPINOZA29 OCT 07
GB5010811600021ASERIWEDPERIODIC 6 MONTHS. FREQ 000182D DUE 20081231P03307H0010000811515005.016PN10ZXPEWASHED UNIT STARTED TO LOOK OVER AND LUBE.NOESPINOZA25 APR 08
GB5010811600021ASERIWEDPERIODIC 6 MONTHS. FREQ 000182D DUE 20081232P03307H0108300811610151.816PN10ZXPEP.E. C/W.NOESPINOZA25 APR 08
GB5010830200011ASERIWEDPERIODIC 6 MONTHS. FREQ 000182D DUE 20083091P03307H0107000831013006.016PN10ZXPEP.E. C/W.NOESPINOZA05 NOV 08
GB5010830200021ASERIWEDSPECIAL WHEEL BEARING PACK DUE. FREQ 000730D DUE 20083091S04114H0107000831109002.016PN10ZXWHEEL BEARING PACKP.E. C/W.NOESPINOZA06 NOV 08
GB5020723200011ASERIWEDPERIODIC 6 MONTHS. FREQ 000182D DUE 20072341P03307H0010000723215005.016PN10ZXPEWASHED UNIT LOOKED UNIT OVER AND STARTED TO LUBE.NOESPINOZA21 AUG 07
GB5020723200011ASERIWEDPERIODIC 6 MONTHS. FREQ 000182D DUE 20072342P03307H0107000723308001.016PN10ZXPEFINISHED LUBING UNIT GAVE FINAL LOOK OVER P.E. C/W.NOESPINOZA21 AUG 07
GB5020804400011ASERIWEDPERIODIC 6 MONTHS. FREQ 000182D DUE 20080511P03307H0107000804313006.016PN10ZXPEP.E. C/W.NOESPINOZA12 FEB 08
GB5020804400021ASERIWEDSPECIAL WHEEL BEARING PACK DUE. FREQ 000730D DUE 20080561S04114H0113000804315002.016PN10ZXWHEEL BEARING PACKPACKED BEARINGS.NOESPINOZA12 FEB 08
GB5020823100011ASERIWEDPERIODIC 6 MONTHS. FREQ 000182D DUE 20082331P03307H0011000823113002.016PN10ZXPELOOKED UNIT OVER PUT IN WASH RACK AND WASHED.NOPN09JR19 AUG 08
GB5020823100011ASERIWEDPERIODIC 6 MONTHS. FREQ 000182D DUE 20082332P03307H0107000823210003.016PN10ZXPEP.E. C/W.NOPN09JR19 AUG 08
GB5020833640001ASERIWEDACCEPTANCE INSPECTION DUE.1PAGENMGF07A0107000834007100.216PN10ZXACCEPTANCE INSPECTION DUE.JOB ENTERED IN ERROR.NOESPINOZA05 DEC 08
GB5020905040001ASERIWEDUNIT PREPPED FOR PAINT.1BAGENMGF23B0111000912615004.016PN10ZXUNIT PREPPED FOR PAINT.RECEIVED FROM PAINT INSTALLED ALL REQUIRED MARKINGS AND REFL ECTIVE TAPE.NOESPINOZA06 MAY 09
GB5020905100011ASERIWEDPERIODIC 6 MONTHS. FREQ 000182D DUE 20090491P03307H0109000912616407.716PN10ZXPEP.E. C/W.NOESPINOZA06 MAY 09
GB5030912840001ASERIWEDWHEEL HAS FLAT SPOT.1BAGENMGF02A0107000913108001.016PN10ZXWHEEL HAS FLAT SPOT.REPLACED WORN WHEEL.NO11 MAY 09

C-1

Eqp-IDEventWCE NBRWorkcenterSRDDiscrepancy NarrDDRTMCPWUC/LCNATWDHMMCCUPSTART TimeDATESTOP TimeHRSCSCat LaborUSER-IdWCE NarrativeCorrective Actioneg_NOINSHOPEvt Comp
GC1010727500021ASERIWEFPERIODIC 6 MONTHS. FREQ 000182D DUE 20072831P03307H0111000727414453.816PN10ZXPERIODIC 6 MONTHS.P.E. C/W.NOESPINOZA01 OCT 07
GC1010809900011ASERIWEFPERIODIC 6 MONTHS. FREQ 000182D DUE 20081001P03307H0109000809811002.016PN10ZXPERIODIC 6 MONTHS.P.E. C/WNOESPINOZA07 APR 08
GC1010826800021ASERIWEFPERIODIC 6 MONTHS. FREQ 000182D DUE 20082821P03307H0110000826812002.016PN10ZXPERIODIC 6 MONTHS.P.E. C/W.NOESPINOZA24 SEP 08
GC1010833140021ASERIWEFUNIT DUE FULL PAINT.1BAGENMGF23B0109000835811002.016PN10ZXUNIT DUE FULL PAINT.GOT UNIT BACK FROM PAINT SHOP INSTALLED ALL MARKINGS AND REF LECTIVE TAPE.NOESPINOZA23 DEC 08
GC1010907600031ASERIWEFPERIODIC 6 MONTHS. FREQ 000182D DUE 20090981P03307H0109030907711302.516PN10ZXPERIODIC 6 MONTHS.P.E. C/W.NOESPINOZA18 MAR 09

Skate

Eqp-IDEventWCE NBRWorkcenterSRD1Discrepancy NarrDDRTMCPWUC/LCNATWDHMMCCUPSTART TimeDATESTOP TimeHRSCSCat LaborUSER-IdWCE NarrativeCorrective Actioneg_NOINSHOPEvt Comp
GDL010726000011ASERIGCHPERIODIC 180 DAY FREQ 000182D DUE 20072601P03307H0107000726013006.016PN10ZXPEP.E. C/W.NOESPINOZA17 SEP 07
GDL010726000021ASERIGCHSPECIAL 360 DAY FREQ 000364D DUE 20072601S04114H0107000726108001.016PN10ZXANNUALP.E. C/W.NOESPINOZA18 SEP 07
GDL010806300021ASERIGCHPERIODIC 180 DAY FREQ 000182D DUE 20080771P03307H0107000806311304.516PN10ZXPEP.E. C/W.NOESPINOZA03 MAR 08
GDL010824700011ASERIGCHPERIODIC 180 DAY FREQ 000182D DUE 20082591P03307H0111000824612301.516PN10ZXPEP.E. C/W.NOESPINOZA02 SEP 08
GDL010824700021ASERIGCHSPECIAL 720 DAY FREQ 000728D DUE 20082591S04114H0112300824615002.516PN10ZXWHEEL BEARING PACKREPACKED BEARINGS.NOESPINOZA02 SEP 08
GDL010824700031ASERIGCHSPECIAL 360 DAY FREQ 000364D DUE 20082591S04114H0107000824708401.716PN10ZXANNUALP.E. C/W.NOESPINOZA03 SEP 08
GDL010906400011ASERIGCHPERIODIC 180 DAY FREQ 000182D DUE 20090751P03307H0109300906512303.016PN10ZXPEP.E. C/W.NOESPINOZA06 MAR 09

Fuel Bowser

Eqp-IDEventWCE NBRWorkcenterSRDDiscrepancy NarrDDRTMCPWUC/LCNATWDHMMCCUPSTART TimeDATESTOP TimeHRSCSCat LaborUSER-IdWCE NarrativeCorrective Actioneg_NOINSHOPEvt Comp
GFB010903840001ASERIWKZUNIT PREPPED FOR PAINT.1BZZ300GF23B0109000906112003.016PN10ZXUNIT PREPPED FOR PAINT.GOT UNIT FROM PAINT SHOP. INSTALLED ALL REQUIRED MARKINGS AN D REFLECTIVE TAPE. UNIT OPS CHECKED GOOD.NOESPINOZA02 MAR 09
GFB020909040001ASERIWKZUNIT PREPPED FOR PAINT.1BZZ300GF23B0107000909910003.016PN10ZXUNIT PREPPED FOR PAINT.RECEIVED FROM PAINT AND INSTALLED ALL REQUIRED MARKINGS AND REFLECTIVE TAPE.NOESPINOZA09 APR 09
GFB020719900011ASERIWKZPERIODIC 180 DAY FREQ 000182D DUE 20071991P03307H0112000719715003.016PN10ZXPESTARTED PE WASHED UNIT STARTED TO LUBE AND LOOK UNIT OVER.NOESPINOZA16 JUL 07
GFB010728200011ASERIWKZPERIODIC 180 DAY FREQ 000182D DUE 20072931P03307H0107000728409002.016PN10ZXPEP.E. C/W.NOESPINOZA11 OCT 07
GFB010728200021ASERIWKZPERIODIC 360 DAY FREQ 000364D DUE 20072951P03309H0111000728315004.016PN10ZXANNUALP.E. C/W.NOESPINOZA10 OCT 07
GFB010728200031ASERIWKZPERIODIC 720 DAY FREQ 000728D DUE 20072951P03310H0107000728311004.016PN10ZXWHEEL BEARING PACKREPACKED BEARINGS.NOESPINOZA10 OCT 07
GFB020800800011ASERIWKZPERIODIC 360 DAY FREQ 000364D DUE 20080141P03309H0107000801009002.016PN10ZXANNUALP.E. C/W.NOESPINOZA10 JAN 08
GFB020800800021ASERIWKZPERIODIC 180 DAY FREQ 000182D DUE 20080161P03307H0109000801011002.016PN10ZXPEP.E. C/W.NOESPINOZA10 JAN 08
GFB010810600011ASERIWKZPERIODIC 180 DAY FREQ 000182D DUE 20081101P03307H0107000810612205.316PN10ZXPEP.E. C/W.NOESPINOZA15 APR 08
GFB020819200021ASERIWKZPERIODIC 180 DAY FREQ 000182D DUE 20081981P03307H0110000819213003.016PN10ZXPEP.E. C/W.NOESPINOZA10 JUL 08
GFB010827400011ASERIWKZPERIODIC 180 DAY FREQ 000182D DUE 20082921P03307H0107000827510003.016PN10ZXPEP.E. C/W.NOPN09JR01 OCT 08
GFB010827400021ASERIWKZPERIODIC 360 DAY FREQ 000364D DUE 20082941P03309H0107000827608301.516PN10ZXANNUALP.E. C/W.NOPN09JR02 OCT 08
GFB020901300011ASERIWKZPERIODIC 360 DAY FREQ 000364D DUE 20090121P03309H0111000901413002.016PN10ZXANNUALP.E. C/W.NOESPINOZA14 JAN 09
GFB020901300021ASERIWKZPERIODIC 720 DAY FREQ 000728D DUE 20090121P03310H0013000901415002.016PN10ZXWHEEL BEARING PACKSTARTED REPACKING BEARINGS.NOESPINOZA15 JAN 09
GFB020901300021ASERIWKZPERIODIC 720 DAY FREQ 000728D DUE 20090122P03310H0107000901509002.016PN10ZXWHEEL BEARING PACKFINISHED PACKING WHEEL BEARINGS.NOESPINOZA15 JAN 09
GFB020901300031ASERIWKZPERIODIC 180 DAY FREQ 000182D DUE 20090141P03307H0107000901411004.016PN10ZXPEP.E. C/W.NOESPINOZA14 JAN 09
GFB010910800011ASERIWKZPERIODIC 180 DAY FREQ 000182D DUE 20091081P03307H0007000911811004.016PN10ZXPESTARTED INSPECTION WASHED UNIT COMPLETED MOST WORK CARDS.NOESPINOZA29 APR 09
GFB010910800011ASERIWKZPERIODIC 180 DAY FREQ 000182D DUE 20091082P03307H0108000911909301.516PN10ZXPEP.E. C/W.NOESPINOZA29 APR 09

B809D

Eqp-IDEventWCE NBRWorkcenterSRDDiscrepancy NarrDDRTMCPWUC/LCNATWDHMMCCUPSTART TimeDATESTOP TimeHRSCSCat LaborUSER-IdWCE NarrativeCorrective Actioneg_NOINSHOPEvt Comp
GDG010727400011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20072861P03307H0107000727515008.016PN10ZXPHASE II INSPECTION.COMPLETED ALL WORK CARDS EXCEPT FOR OPS CHECK.NOESPINOZA03 OCT 07
GDG010727400011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20072862P03307H0107000727608001.016PN10ZXPHASE II INSPECTION.RAN UNIT OPS CHECKED GOOD. P.E. C/W.NOESPINOZA03 OCT 07
GDG010802640001ASERIWXJBATTERIES DEAD.1BAGEPGLF16A0109000802810301.516PN10ZXBATTERIES DEAD.REPLACED BATTERIES RAN UNIT OPS CHECKED GOOD.NOESPINOZA28 JAN 08
GDG010802840021ASERIWXJREGULATOR CARD BAD.1BAGEPGGF16A0113000802815002.016PN10ZXREGULATOR CARD BAD.REPLACED REGULATOR CARD RAN UNIT OPS CHECKED GOOD.NO28 JAN 08
GDG010803740011ASERIWXJWITH DC VOLTAGE APPLIED TO A/C WHEN LOAD CHANGES CAUSES VOLT AGE TO FLUXUATE AND GET DC OVERVOLTAGE.1BAGEPGGF16A0109000803911002.016PN10ZXWITH DC VOLTAGE APPLIED TO A/C WHEN LOAD CHANGES CAUSES VOLT AGE TO FLUXUATE AND GET DC OVERVOLTAGE.REPLACED REGULATOR CIRCUIT CARD. RAN UNIT OPS CHECKED GOOD.NOESPINOZA08 FEB 08
GDG010803740021ASERIWXJAC CONTACTOR WON'T OPEN WITH CABLE DISCONNECTED. BAD INTERLO1BAGEPGGF16A0111000803912001.016PN10ZXAC CONTACTOR WON'T OPEN WITH CABLE DISCONNECTED. BAD INTERLO CK RELAY.REPLACED INTERLOCK RELAY. RAN UNIT OPS CHECKED GOOD.NO08 FEB 08
GDG010805740001ASERIWXJAC PWR WAS LOW AND FLUXUATES. CONTACTOR WONT DROP OFF WITH C ABLE DISCONNECTED.1BAGEPGGF16A0107000805709002.016PN10ZXAC PWR WAS LOW AND FLUXUATES. CONTACTOR WONT DROP OFF WITH C ABLE DISCONNECTED.REPLACED REGULATOR CARD AND INTERLOCK RELAY. RAN UNIT OPS CH ECKED GOOD.NOESPINOZA26 FEB 08
GDG010810000011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20081031P03309H0007000809815008.016PN10ZXPHASE I INSPECTION.COMPLETED ALL WORK CARDS AND INSPECTED BEARINGS FOR ONE TIME AND FOUND THEY NEEDED TO BE PACKED STARTED TO REPACK.NOESPINOZA09 APR 08
GDG010810000011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20081032P03309H0107000810011004.016PN10ZXPHASE I INSPECTION.FINISHED PACKING BEARING PUT UNIT ON LOAD BANK AND RAN UNIT OPS CHECKED GOOD. P.E. C/W.NOESPINOZA09 APR 08
GDG010827300011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20082861P03307H0007000827312005.016PN10ZXPHASE II INSPECTION.REPLACED OIL AND OIL FILTER. REPLACED FUEL FILTERS AND DRAINED LOW POINTS. PUT IN WASH RACK AND WASHED.NOESPINOZA01 OCT 08
GDG010827300011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20082862P03307H0108000827513005.016PN10ZXPHASE II INSPECTION.COMPLETED WORK CARDS PUT UNIT ON LOAD BAND AND RAN OPS CHECKED GOOD. P.E. C/W.NOESPINOZA01 OCT 08
GDG010831540011ASERIWXJAC UNDER VOLTAGE FAULT COMES ON.1BAGEPGGF16A0107000831709302.516PN10ZXAC UNDER VOLTAGE FAULT COMES ON.SWAPPED AC CIRCUIT CARDS RAN UNIT ON LOAD BANK UNIT OPS CHEC KED GOOD.NOESPINOZA12 NOV 08
GDG010910400011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20091021P03309H0012000910515003.016PN10ZXPHASE I INSPECTION.REPLACED OIL AND OIL FILTER PUT IN WASH RACK AND WASHED.NOESPINOZA22 APR 09
GDG010910400011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20091022P03309H0109000911215006.016PN10ZXPHASE I INSPECTION.P.E. C/W.NOESPINOZA22 APR 09
GDG020723140001ASERIWXJUNIT WON'T START BATTERIES LOW.1BAGEPGGF06B0107000723208001.016PN10ZXUNIT WON'T START BATTERIES LOW.REPLACED BATTERIES STARTED UNIT. UNIT OPS CHECKED GOOD.NO20 AUG 07
GDG020725400011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20072571P03307H0009300725315005.516PN10ZXPHASE II INSPECTION.STARTED INSPECTION. REPLACED OIL AND OIL FILTER WASHED UNIT AND STARTED TO LUBE.NOESPINOZA12 SEP 07
GDG020725400011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20072572P03307H0107000725509552.916PN10ZXPHASE II INSPECTION.FINISHED LUBE AND LOOKED UNIT OVER. PUT ON LOAD BANK AND RAN UNIT OPS CHCEK GOOD. P.E. C/W.NOESPINOZA12 SEP 07
GDG020728200041ASERIWXJDC VOLTAGE DROPS OFF LINE WITH LOAD.1BAGEPGHF79C0107000728208151.316PN10ZXDC VOLTAGE DROPS OFF LINE WITH LOAD.PUT UNIT ON LOAD BANK AND RAN PUT UNDER LOAD AND CYCLED POWE R ON AND OFF REPEATEDLY NEVER GOT UNIT TO FAIL. CYCLED LOAD ON AND OFF LOAD BANK NUMEROUS TIME UNIT NEVER DROPPED OFF LI NE UNIT OPS CHECK GOOD C/N/D.NO09 OCT 07
GDG020729640001ASERIWXJMASTER SWITCH LEFT ON BATTERIES DEAD.1BAGEPGGF16A0107000729608001.016PN10ZXMASTER SWITCH LEFT ON BATTERIES DEAD.REPLACED BATTERIES RAN UNIT OPS CHECK GOOD.NOESPINOZA23 OCT 07
GDG020806400021ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20080781P03309H0011300806315003.516PN10ZXPHASE I INSPECTION.REPLACED OIL AND OIL FILTER. LOOKED UNIT OVER PUT IN WASH RACK AND WASHED.NOESPINOZA04 MAR 08
GDG020806400021ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20080782P03309H0107000806413006.016PN10ZXPHASE I INSPECTION.FINISHED WORK CARDS PUT UNIT ON LOAD BANK RAN UNIT OPS CHECKED GOOD. P.E. C/W.NOESPINOZA04 MAR 08
GDG020824600011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20082571P03307H0007000824813006.016PN10ZXPHASE II INSPECTION.REPLACED FILTERS WASHED UNIT. FOUND WATER IN BEARINGS STARTED TO REPACK BEARINGS.NOESPINOZA09 SEP 08
GDG020824600011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20082572P03307H0007000825209002.016PN10ZXPHASE II INSPECTION.FINISHED PACKING BEARINGS AND COMPLETED WORK CARDS EXCEPT FOR OPS CHECKS.NOESPINOZA09 SEP 08
GDG020824600011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20082573P03307H0107000825308001.016PN10ZXPHASE II INSPECTION.RAN UNIT OPS CHECKED GOOD P.E. C/W.NOESPINOZA09 SEP 08
GDG020900740001ASERIWXJUNIT WON'T START.1BAGEPGGF12A0108000900812004.016PN10ZXUNIT WON'T START.FOUND UNIT WASN'T GETTING FUEL. REFILLED BOTH FUEL FILTERS A ND BLED FUEL SYSTEM UNIT RAN AND OPS CHECKED GOOD.NOESPINOZA08 JAN 09
GDG020909140001ASERIWXJUNIT PREPPED FOR PAINT.1PAGEPGGF23B0107000909211004.016PN10ZXUNIT PREPPED FOR PAINT.RECEIVED FROM PAINT INSTALLED ALL REQUIRED MARKINGS AND REFL ECTIVE TAPE.NOESPINOZA02 APR 09
GDG020907600011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20090771P03309H0011000909615004.016PN10ZXPHASE I INSPECTION.REPLACED OIL AND OIL FILTER. STARTED TO LUBE AND LOOK UNIT OVER.NOESPINOZA08 APR 09
GDG020907600011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20090772P03309H0105000909807002.016PN10ZXPHASE I INSPECTION.COMPLETED ALL WORK CARDS PUT UNIT ON LOAD BANK AND RAN UNIT OPS CHECKED GOOD. P.E. C/W.NOESPINOZA08 APR 09
GDG030727600011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20072851P03309H0007000727715008.016PN10ZXPHASE I INSPECTION.P.E. C/W.NOESPINOZA05 OCT 07
GDG030727600011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20072852P03309H0107000727808001.016PN10ZXPHASE I INSPECTION.P.E. C/W.NOESPINOZA05 OCT 07
GDG030810100011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20081031P03307H0007000809915008.016PN10ZXPHASE II INSPECTION.REPLACED OIL AND OIL FILTER. REPLACED FUEL FILTER AND AIR FILTER CHECKED BEARINGS FOUND THEY NEED TO BE REPACKED.NOESPINOZA10 APR 08
GDG030810100011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20081032P03307H0111000810015004.016PN10ZXPHASE II INSPECTION.REMOVED BEARINGS AND CLEANED. STARTED TO REPACK.NOESPINOZA10 APR 08
GDG030810100011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20081033P03307H0107000810111004.016PN10ZXPHASE II INSPECTION.FINISED PACKING BEARINGS AND THE REST OF THE WORK CARDS PUT UNIT ON LOAD BANK AND RAN OPS CHECK GOOD. P.E. C/W.NOESPINOZA10 APR 08
GDG030826900011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20082851P03309H0012000826815003.016PN10ZXPHASE I INSPECTION.REPLACED OIL AND OIL FILTER LOOKED OVER PUT IN WASH RACK AND WASHED.NOESPINOZA25 SEP 08
GDG030826900011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20082852P03309H0107000826910303.516PN10ZXPHASE I INSPECTION.P.E. C/W.NOESPINOZA25 SEP 08
GDG030910500011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20091021P03307H0107000910512005.016PN10ZXPHASE II INSPECTION.REPLACED OIL, OIL FILTER, FUEL FILTERS AND AIR FILTER. WASHED UNIT AND STARTED TO LUBE.NOESPINOZA16 APR 09
GDG030910500011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20091022P03307H0110000910613303.516PN10ZXPHASE II INSPECTION.FINISHED WORK CARDS PUT UNIT ON LOAD BANK AND RAN UNIT OPS CHECKED GOOD. P.E. C/W.NOESPINOZA16 APR 09
GDG030913340001ASERIWXJAC VOLTAGE DROPS OFF.1BAGEPGGF16A0107000914012005.016PN10ZXAC VOLTAGE DROPS OFF.FOUND INTERLOCK RELAY BAD REPLACED RELAY RAN UNIT OPS CHECKE D GOOD.NOESPINOZA20 MAY 09
GDG040730400011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20073111P03309H0007000730411004.016PN10ZXPHASE I INSPECTION.REPLACED OIL AND OIL FILTER. WASHED UNIT STARTED LOOKING OVER AND LUBE.NOESPINOZA01 NOV 07
GDG040730400011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20073112P03309H0107000730511004.016PN10ZXPHASE I INSPECTION.P.E. C/W.NOESPINOZA01 NOV 07
GDG040811740001ASERIWXJBATTERIES DEAD.1BAGEPGGF16A0107000811908301.516PN10ZXBATTERIES DEAD.REPLACED BATTERIES RAN UNIT OPS CHECKED GOOD.NOESPINOZA28 APR 08
GDG040813400011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20081341P03307H0011000813315004.016PN10ZXPHASE II INSPECTION.REPLACED OIL, OIL FILTER, AND FUEL FILTERS. PUT UNIT IN WASH RACK AND WASHED.NOESPINOZA15 MAY 08
GDG040813400011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20081342P03307H0011000813514303.516PN10ZXPHASE II INSPECTION.BROUGHT UNIT IN REPLACED AIR FILTER. LUBED UNIT AND LOOKED OVER CONNECTED BATTERIES ALL WORK CARDS C/W EXCEPT OPS CHK.NOESPINOZA15 MAY 08
GDG040813400011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20081343P03307H0107000813609502.816PN10ZXPHASE II INSPECTION.RAN UNIT OPS CHECKED GOOD. P.E. C/W.NOESPINOZA15 MAY 08
GDG040830300011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20083111P03309H0007000830912005.016PN10ZXPHASE I INSPECTION.REPLACED OIL AND OIL FILTER PUT IN WASH RACK AND WASHED UNIT.NOESPINOZA06 NOV 08
GDG040830300011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20083112P03309H0111000831114303.516PN10ZXPHASE I INSPECTION.P.E. C/W.NOESPINOZA06 NOV 08
GDG040913200021ASERIWXJBEARING PACK DUE. FREQ 000730D DUE 20091331S04114H0107000913912005.016PN10ZXBEARING PACK DUE.REPACKED WHEEL BEARINGS.NOESPINOZA19 MAY 09
GDG050726200011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20072661P03309H0107000726214307.516PN10ZXPHASE I INSPECTION.P.E. C/W.NOESPINOZA19 SEP 07
GDG050803740031ASERIWXJAC CONTACTOR WON'T OPEN WITH CABLE DISCONNECTED. BAD INTERLO CK RELAY.1BAGEPGGF16A0107000804209002.016PN10ZXAC CONTACTOR WON'T OPEN WITH CABLE DISCONNECTED. BAD INTERLO CK RELAY.REPLACED INTERLOCK RELAY. RAN UNIT OPS CHECKED GOOD.NO11 FEB 08
GDG050806540001ASERIWXJDC VOLTAGE READS 26 VOLTS.1BAGEPGLF16A0108000806910002.016PN10ZXDC VOLTAGE READS 26 VOLTS.CHECKED VOLTAGE ON LOAD BANK READ 28.55 VOLTS GAGE STILL SHO WED 26. SAW NEEDLE WAS STUCK TO THE METER FACE. REMOVED VOLT METER AND REPAIRED NEEDLE INSATLLED BACK IN UNIT. RAN UNIT NOW OPS CHECKED GOOD.NO09 MAR 08
GDG050808400011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20080841P03307H0007000808415008.016PN10ZXPHASE II INSPECTION.REPLACED ALL FILTERS AND WASHED UNIT BROGHT IN FOUND BEARINGS WET SO STARTED REPACKING BEARINGS.NOPN09JR26 MAR 08
GDG050808400011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20080842P03307H0007000808512005.016PN10ZXPHASE II INSPECTION.FINISHED PACKING BEARINGS AND COMPLETED ALL WORK CARD EXCEPT FOR OPS CHECK.NOPN09JR26 MAR 08
GDG050808400011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20080843P03307H0112000808613001.016PN10ZXPHASE II INSPECTION.RAN UNIT OPS CHECK GOOD. P.E. C/W.NOPN09JR26 MAR 08
GDG050825500011ASERIWXJPHASE I INSPECTION ANNUAL. FREQ 000365D DUE 20082621P03309H0110150825415004.816PN10ZXPHASE I INSPECTION.P.E. C/W.NOESPINOZA10 SEP 08
GDG050907400011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20090831P03307H0012000907415003.016PN10ZXPHASE II INSPECTION.REPLACED OIL, OIL FILTER, FUEL FILTERS AND AIR FILTER. PUT IN WASH RACK AND WASHED.NOESPINOZA17 MAR 09
GDG050907400011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20090832P03307H0011000907515004.016PN10ZXPHASE II INSPECTION.COMPLETED ALL WORK CARDS EXCEPT FOR OPS CHECKS.NOESPINOZA17 MAR 09
GDG050907400011ASERIWXJPHASE II INSPECTION ANNUAL. FREQ 000365D DUE 20090833P03307H0107000907609002.016PN10ZXPHASE II INSPECTION.GAVE UNIT FINAL LOOK OVER PUT ON LOAD BANK AND RAN UNIT. UNIT OPS CHECKED GOOD P.E. C/W.NOESPINOZA17 MAR 09
GDG050914540001ASERIWXJAC VOLTAGE WON'T STAY ON LINE.1BAGEPGGF16A0110000914612002.016PN10ZXAC VOLTAGE WON'T STAY ON LINE.FOUND INTERLOCK RELAY TO BE BAD. REPLACED RELAY RAN UNIT OPS CHECKED GOOD.NO26 MAY 09
GDG060716940001ASERIWXJUNIT IS HARD TO START EVERY MORNING.1BAGEPGGF38A0110000717314004.016PN10ZXUNIT IS HARD TO START EVERY MORNING.WAS UNDER WARRANTY AND THEY REPLACED THE FUEL PUMP. LET UNIT SIT OVER WEEKEND AND STARTED RIGHT UP UNIT OPS CHECK GOOD.NO22 JUN 07
GDG060721140001ASERIWXJDC POWER CABLE DUE INSTALLATION.1BAGEPGGF16A0107000721110003.016PN10ZXDC POWER CABLE DUE INSTALLATION.INSTALLED DC POWER CABLE. RAN UNIT AND ADJUSTED DC CIRCUIT C ARD UNIT OPS CHECKRD GOOD.NOESPINOZA30 JUL 07