metal_lockers.pdf
PDF 26 KB Posted
- Attached to
- F35 Fuel Cell Maintenance Facility - FA5004-18-B-C009 Federal contract opportunity
- Solicitation number
- F500418BA005
About this file
Metal Locker Specs
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Grp_5_QA.pdf | ||
| FA500418BA0050002.pdf | ||
| Grp_4_QA.pdf | ||
| Grp3QA.pdf | ||
| mech.pics17-24.pdf | ||
| eye.wash.pics.pdf | ||
| mech.pics_1-8.pdf | ||
| Grp2_QA.pdf | ||
| existing.paint.stripping.pdf | ||
| mech.pics_9-16.pdf | ||
| plumbing.pdf | ||
| Grp1_QA.pdf | ||
| FA500418BA0050001.SF_30.pdf | ||
| JA-6_Wage_Determination.pdf | ||
| JA-9_Asbuilts.pdf | ||
| JA-4_FTQW_18-0205_Final_Drawings_11x17.pdf | ||
| JA-8__Brand_Name_Justification_Det-Tronics.pdf | ||
| Solicitation_-_FA500418BA005.pdf | ||
| JA-6_Wage_Determination_.pdf | ||
| JA-3_Final_Construction_Docs_Vol_1_Bk_2.pdf | ||
| JA-1_Synopsis_of_Work.pdf | ||
| JA-5_FTQW_18-0205_Final_Drawings_22x34.pdf | ||
| JA-7_Submittal_Register.pdf | ||
| JA-2_Final_Construction_Docs_Vol_1_Bk_1.pdf |
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F-35 FUEL CELL MAINTENANCE FACILITY RENOVATION FINAL
FTQW 18-0205
SECTION TABLE OF CONTENTS
DIVISION 10 - SPECIALTIES
SECTION 10 51 13
METAL LOCKERS
05/11
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 DELIVERY, HANDLING, AND STORAGE
1.4 FIELD MEASUREMENTS
1.5 QUALITY ASSURANCE
1.5.1 Color Chips
PART 2 PRODUCTS
2.1 TYPES
2.1.1 Single-tier Lockers
2.1.2 Locker Benches
2.2 MATERIAL
2.2.1 Galvanized Steel Sheet
2.2.2 Chromium Coating
2.2.3 Finish
2.2.3.1 Color
2.3 COMPONENTS
2.3.1 Built-In Locks
2.3.2 Coat Hooks
2.3.3 Hat Shelf
2.3.4 Door Handles
2.3.5 Doors
2.3.5.1 Hinges
2.3.5.2 Latching Mechanisms
2.3.6 Latch Strikes
2.3.7 Silencers
2.3.8 Back and Side Panels, Tops, and Bottoms
2.3.9 Sloping Locker Tops
2.3.10 Infill Panels
2.3.11 Shelves
2.3.12 Base Panels
2.3.13 Legs
2.3.14 Number Plates
2.3.15 Fastening Devices
PART 3 EXECUTION
3.1 ASSEMBLY AND INSTALLATION
3.2 FIELD QUALITY CONTROL
3.2.1 Testing
3.2.2 Repairing
3.2.3 Cleaning
SECTION 10 51 13 Page 1
-- End of Section Table of Contents --
SECTION 10 51 13 Page 2
SECTION 10 51 13
METAL LOCKERS
05/11
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM A1008/A1008M (2016) Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable
ASTM A568/A568M (2017a) Standard Specification for Steel, Sheet, Carbon, Structural, and High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, General Requirements for
ASTM A653/A653M (2017) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
ASTM A924/A924M (2017a) Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process
ASTM D6386 (2016) Standard Practice for Preparation of Zinc (Hot-Dip Galvanized) Coated Iron and Steel Product and Hardware Surfaces for Painting
U.S. DEPARTMENT OF DEFENSE (DOD)
MIL-PRF-22750 (2011; Rev G) Coating, Epoxy, High Solids
MIL-PRF-23377 (2012; Rev K) Primer Coatings: Epoxy, High Solids
U.S. GENERAL SERVICES ADMINISTRATION (GSA)
FS AA-L-00486 (Rev J) Lockers, Clothing, Steel
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in
SECTION 10 51 13 Page 3 accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Types; G
SD-03 Product Data
Material; G
Locking Devices; G
Handles; G
Finish; G
Locker components; G
SD-04 Samples
Color chips; G
1.3 DELIVERY, HANDLING, AND STORAGE
Deliver lockers and associated materials in their original packages, containers, or bundles bearing the manufacturer's name and the name of the material. Protect from weather, soil, and damage during delivery, storage, and construction.
1.4 FIELD MEASUREMENTS
To ensure proper fits, make field measurements prior to the preparation of drawings and fabrication. Verify correct location
1.5 QUALITY ASSURANCE
1.5.1 Color Chips
Provide a minimum of three color chips, not less than 3 inches square, of each color scheduled.
Government may request performance-characteristic tests on assembled lockers. Tests and results must conform to FS AA-L-00486. Lockers not conforming will be rejected.
PART 2 PRODUCTS
2.1 TYPES
Locker must have the following type and size in the location and quantities indicated. Locker finish colors will be as scheduled.
2.1.1 Single-tier Lockers
Single-tier lockers must be as follows:
Type STL-1: Single-tier locker 12 inches wide, 15 inches deep, and 72 inches high, attached to 4-inch high base. Locker Body; 24 gage, 0.0239-inch.
SECTION 10 51 13 Page 4
2.1.2 Locker Benches
a. Free standing type; bench top of solid high density polyethylene (HDPE); painted steel pedestals.
b. Height: 17 minimum to 19 maximum.
c. Length: Per Drawings.
2.2 MATERIAL
2.2.1 Galvanized Steel Sheet
ASTM A653/A653M and ASTM A924/A924M, commercial quality, minimized spangle, galvanized steel sheet with not less than G60 zinc coating. Prepare surface of sheet for painting in accordance with ASTM D6386, Method A.
Minimum uncoated sheet thickness .
2.2.2 Chromium Coating
Nickel and chromium electrodeposited on the specified base metal. Conform to ASTM B456, SC-3, as applicable to the base metal.
2.2.3 Finish
FS AA-L-00486.
2.2.3.1 Color
As selected.
2.3 COMPONENTS
2.3.1 Built-In Locks
FS AA-L-00486. Provide locking devices as a padlock eye in the door latching mechanism.
2.3.2 Coat Hooks
FS AA-L-00486, zinc plated, 2 coat hooks.
2.3.3 Hat Shelf
FS AA-L-00486.
2.3.4 Door Handles
FS AA-L-00486. Provide zinc alloy or steel handles with a chromium coating.
2.3.5 Doors
FS AA-L-00486, not less than 0.0598 inch thick steel sheet.
2.3.5.1 Hinges
In addition to the requirements of FS AA-L-00486, provide 5-knuckle hinges, minimum 2 inches high. Fabricate knuckle hinges from not less than 0.0787
SECTION 10 51 13 Page 5 inch thick steel sheet. A full height piano hinge may be provided if standard with the manufacturer. Weld or bolt hinges to the door frame.
Weld, bolt, or rivet hinges to the door.
2.3.5.2 Latching Mechanisms
FS AA-L-00486.
2.3.6 Latch Strikes
FS AA-L-00486. Fabricate from not less than 0.0787 inch thick steel sheet, except latch strike may be continuous from top to bottom and fabricated as part of the door framing.
2.3.7 Silencers
FS AA-L-00486.
2.3.8 Back and Side Panels, Tops, and Bottoms
FS AA-L-00486, not less than 0.0474 inch thick steel sheet.
2.3.9 Sloping Locker Tops
Provide sloping locker tops in addition to the locker-section flat tops.
Sloping tops must be continuous in length. Provide fillers or closures at the exposed end of sloping tops. Fabricate sloping tops from not less than 0.0478-inch thick steel sheet.
2.3.10 Infill Panels
Provide metal infill panels and framing at all interior corners of adjoining lockers. panel infill to match gage and color of locker body.
2.3.11 Shelves
FS AA-L-00486. Fabricate from not less than 0.0598 inch thick steel sheet.
2.3.12 Base Panels
FS AA-L-00486.
2.3.13 Legs
Provide lockers without legs, as indicated.
2.3.14 Number Plates
FS AA-L-00486. Zinc. Provide consecutive numbers starting from 101.
2.3.15 Fastening Devices
Provide bolts, nuts, and rivets as specified in FS AA-L-00486.
PART 3 EXECUTION
3.1 ASSEMBLY AND INSTALLATION
Assemble lockers according to the locker manufacturer's instructions.
SECTION 10 51 13 Page 6
Align lockers horizontally and vertically. Secure lockers to wall and base with screws as indicated. Bolt adjacent lockers together. Adjust doors to operate freely without sticking or binding and to ensure they close tightly.
3.2 FIELD QUALITY CONTROL
3.2.1 Testing
Government may request performance-characteristic tests on assembled lockers in accordance with FS AA-L-00486. Lockers not conforming will be rejected.
3.2.2 Repairing
Remove and replace damaged and unacceptable portions of completed work with new.
3.2.3 Cleaning
Clean surfaces of the work, and adjacent surfaces soiled as a result of the work, in an approved manner. Remove equipment, surplus materials, and rubbish from the site.
-- End of Section --
SECTION 10 51 13 Page 7
| 10 51 13.pdf |
| METAL LOCKERS |
| 10 51 13 - METAL LOCKERS |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 SUBMITTALS |
| 1.3 DELIVERY, HANDLING, AND STORAGE |
| 1.4 FIELD MEASUREMENTS |
| 1.5 QUALITY ASSURANCE |
| 1.5.1 Color Chips |
| PART 2 PRODUCTS |
| 2.1 TYPES |
| 2.1.1 Single-tier Lockers |
| 2.1.2 Locker Benches |
| 2.2 MATERIAL |
| 2.2.1 Galvanized Steel Sheet |
| 2.2.2 Chromium Coating |
| 2.2.3 Finish |
| 2.2.3.1 Color |
| 2.3 COMPONENTS |
| 2.3.1 Built-In Locks |
| 2.3.2 Coat Hooks |
| 2.3.3 Hat Shelf |
| 2.3.4 Door Handles |
| 2.3.5 Doors |
| 2.3.5.1 Hinges |
| 2.3.5.2 Latching Mechanisms |
| 2.3.6 Latch Strikes |
| 2.3.7 Silencers |
| 2.3.8 Back and Side Panels, Tops, and Bottoms |
| 2.3.9 Sloping Locker Tops |
| 2.3.10 Infill Panels |
| 2.3.11 Shelves |
| 2.3.12 Base Panels |
| 2.3.13 Legs |
| 2.3.14 Number Plates |
| 2.3.15 Fastening Devices |
| PART 3 EXECUTION |
| 3.1 ASSEMBLY AND INSTALLATION |
| 3.2 FIELD QUALITY CONTROL |
| 3.2.1 Testing |
| 3.2.2 Repairing |
| 3.2.3 Cleaning |
File details come from the government source that posted it.