Express Menu.pdf
PDF 97 KB Posted
- Attached to
- Construction Services Indefinite Delivery Indefinite Quantity Contract Federal contract opportunity
- Solicitation number
- 47PK0120R0003
About this file
This is a solicitation for multiple award indefinite delivery indefinite quantity construction services contracts in four geographic zones. The solicitation seeks proposals for construction services contracts with a total small business set-aside in Zone 1 covering Arizona and Nevada, Zone 2 covering Northern California, Zone 3 covering Hawaii, and Zone 4 covering Southern California. Proposers should review the attached solicitation documents for details on submission requirements. The General Services Administration Public Buildings Service Region 9 is the contracting agency. Proposals are due based on instructions in the solicitation documents. Awards will be made for IDIQ contracts to provide construction services on an as-needed basis within the specified zones over the terms of the contracts.
View the file
Other files for this federal contract opportunity
Show all 34
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Express Menu
ID Description Unit Rate|Clab 1 Common Laborer hourly rate HR Rate|Carp 1 Carpenter hourly rate HR Rate|Elec 1 Electrician hourly rate HR Rate|Plum 1 Plumber hourly rate HR 02411 916 8500 Selective demolition, cutout, remove, minimum labor/equipment charge Job 02411 919 2000 Selective demolition, rubbish handling, 0'-50' haul, load, haul, dump and return, hand carried, cost to be added to demolition cost C.Y.
02821 339 0100 Asbestos remediation, plans and methods, building survey, commercial Ea.
02821 342 0100 Preparation of asbestos containment area, pre-cleaning, HEPA vacuum and wet wipe, flat surfaces S.F.
02821 342 0200 Preparation of asbestos containment area, protect carpeted area, 2 layers 6 mil poly on 3/4" plywood S.F.
02821 342 0300 Preparation of asbestos containment area, separation barrier, 2" x 4" @ 16", 1/2" plywood each side, 8' high S.F.
02821 342 0550 Preparation of asbestos containment area, cover surfaces with polyethylene sheeting, floors, each layer, 6 mil, incl. glue & tape S.F.
02821 346 0200 Decontamination of asbestos containment area, spray exposed substrate with surfactant (bridging), flat surfaces S.F.
02821 346 4100 Decontamination of asbestos containment area, remove portable decontamination facility Ea.
02821 348 0100 Asbestos encapsulation with sealants, ceilings & walls, min S.F.
02821 348 0110 Asbestos encapsulation with sealants, ceilings & walls, max S.F.
02831 926 4800 Removal of lead-based paint, by chemicals, per application, siding S.F.
02831 926 9000 Removal of lead-based paint, minimum labor/equipment charge Job 03013 062 0100 Patching concrete, floors, small area, regular grout, 1/4" thick S.F.
03354 310 0110 Polished concrete floors, processing of interior floors, removal of glue, adhesive or tar, includes dry grinding with planetary floor grinder, dry vac pick-up, hand sweeping M.S.F.
03821 310 0500 Concrete core drilling, core, reinforced concrete slab, 4" diameter, up to 6" thick slab, includes bit cost, layout and set up time Ea.
03821 310 0550 Concrete core drilling, core, reinforced concrete slab, 4" diameter, up to 6" thick slab, includes bit cost, layout and set up time, for each additional inch of slab thickness in same hole, add Ea.
04012 020 0300 Pointing masonry, tuck, cut and re-point, hard mortar, running bond S.F.
04012 020 1000 Pointing masonry, re-point, mask and grout method, running bond S.F.
04012 020 9000 Pointing masonry, minimum labor/equipment charge Job 04012 030 0300 Pointing masonry, cut and re-point block, hard mortar, running bond S.F.
04050 510 0420 Selective demolition, masonry, concrete block walls, reinforced alternate courses, 10" thick S.F.
05122 317 9000 Column, columns, minimum labor/equipment charge Job 05411 330 4340 Partition, galvanized LB studs, 16 ga x 3-5/8" W studs 16" OC x 8' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging L.F.
06050 520 1220 Selective demolition, millwork and trim, casework, selective area, remove S.F.
06163 610 0802 Sheathing, plywood on walls, CDX, 3/4" thick S.F.
06221 315 5215 Moldings, base, ogee profile, 9/16" x 4-1/2", red oak L.F.
06221 345 0900 Moldings, trim, chair rail, stock pine, 3-1/2" x 5/8" thick L.F.
06481 310 0400 Exterior wood door frames, pine, 5/4" x 4-9/16" deep, incl. exterior trim L.F.
07211 310 2100 Wall insulation, rigid, expanded polystyrene, 1" thick, R3.85 S.F.
07211 620 0020 Blanket insulation, for walls or ceilings, kraft faced fiberglass, 3-1/2" thick, R11, 15" wide S.F.
07211 620 0160 Blanket insulation, for walls or ceilings, kraft faced fiberglass, 6" thick, R19, 15" wide S.F.
07211 620 1320 Blanket insulation, for walls or ceilings, mineral wool batts, 3-1/2" thick, R15 S.F.
08050 510 0200 Door demolition, exterior door, single, 3' x 7' high, 1-3/4" thick, remove Ea.
08050 510 0220 Door demolition, exterior door, double, 6' x 7' high, 1-3/4" thick, remove Ea.
08050 510 0500 Door demolition, interior door, single, 3' x 7' high, 1-3/8" thick, remove Ea.
08050 510 2000 Door demolition, door frames, metal, remove Ea.
08050 510 2205 Door demolition, door hardware, remove Ea.
08050 510 3300 Door demolition, special doors, sliding glass, remove Ea.
08050 510 3400 Door demolition, special doors, overhead, commercial, 12' x 12' high, remove Ea.
08050 510 3440 Door demolition, special doors, overhead, commercial, 20' x 16' high, remove, includes frames Ea.
08050 510 4000 Door demolition, residential lockset, exterior, remove Ea.
08050 510 9000 Door demolition, minimum labor/equipment charge Job 08050 520 0600 Window demolition, glass, up to 10 S.F. per window S.F.
08111 610 9000 Doors & frames, minimum labor/equipment charge Job 08121 313 7900 Frames, hollow metal, transom lite frames, fixed, add S.F.
08121 320 0460 Frames, steel, wrap around, 16 ga., 6-1/4" x 7'-0" x 3'-0" wide Ea.
08121 320 0580 Frames, steel, wrap around, 16 ga., 6-1/4" x 7'-0" x 6'-0" wide Ea.
08131 313 0100 Doors, hollow metal, commercial, steel, flush, full panel, hollow core, 1-3/8" thick, 20 ga., 3'-0" x 7'-0" Ea.
08131 313 1760 Doors, commercial, steel, insulated, full panel, 18 ga., 3'-0" x 7'-0" x 1-3/4" thick Ea.
08131 313 2000 For vision lite, add Ea.
08131 325 3160 Doors, fire, "B" label, exterior, steel, commercial, flush, 1-3/4" x 7'-0" x 3'-0" wide Ea.
08131 610 5050 Doors, aluminum, commercial entrance, flush panel doors, single, 3'-0" x 7'-0", incl. hinges, push/pull, deadlock, cylinder, threshold, excl. glazing Ea.
08141 310 3020 Doors, solid wood, six panel, mahogany, 1-3/4" thick stile and rail, 3'-0" x 7'-0" Ea.
08141 310 3200 Doors, solid wood, six panel, red oak, 1-3/4" thick stile and rail, 3'-0" x 7'-0" Ea.
08141 610 1840 Doors, wood, decorator, exterior, flush, solid core, birch, 1-3/4" x 7'-0" x 3'-0" wide Ea.
08141 620 0790 Doors, wood, fire, particle core, 7 face plies, "B" label, 90 minutes, birch face, 1-3/4" x 3'-0" x 7'-0" Ea.
08143 320 2740 Doors, wood, residential, interior, closet, bi-fold, flush, birch, 6'-6" or 6'-8" x 3'-0" wide, incl. hardware, excl. frame and trim Ea.
08311 310 6100 Doors, specialty, access, standard, metal, 8" x 8" Ea.
08311 310 6150 Doors, specialty, access, standard, metal, 12" x 12" Ea.
08311 310 6200 Doors, specialty, access, standard, metal, 18" x 18" Ea.
08311 310 6250 Doors, specialty, access, standard, metal, 24" x 24" Ea.
08311 310 6300 Doors, specialty, access, standard, metal, 24" x 36" Ea.
08311 310 6350 Doors, specialty, access, standard, metal, 36" x 36" Ea.
08321 310 5010 Doors, aluminum sliding glass door system, 4' wide opening single side, 4'x7' Ea.
08332 310 0130 Doors, rolling service, steel, manual, standard, 20 gauge, 12' x 12' high, incl. hardware Ea.
08332 310 0750 Doors, rolling service, steel, manual, 20 gauge, 16' x 24' high, incl. hardware Opng.
08712 010 0020 Door hardware, bolts, flush, standard, concealed Ea.
08712 030 0020 Door hardware, door closer, rack and pinion, adjustable backcheck, 3 way mount, all sizes, regular arm Ea.
08712 030 0040 Door hardware, door closer, rack and pinion, adjustable backcheck, 3 way mount, hold open arm Ea.
08712 030 1525 Door hardware, door closer, rack and pinion, backcheck, overhead concealed, all sizes, concealed arm Ea.
08712 036 0550 Door hardware, panic device, for rim locks, single door, standard duty, touch bar narrow stile, US28 Ea.
08712 036 1060 Door hardware, panic device, rim locks, single door, touch bar, wide style, standard duty, surface vertical vod, US28 Ea.
08712 040 4030 Door hardware, lockset, keyless, pushbutton type, industrial, heavy duty, with deadbolt, key override Ea.
08712 042 0100 Door hardware, mortise lockset, commercial, wrought knobs and full escutcheon trim, keyed, office/entrance/apartment, grade 2 Ea.
08712 050 0020 Door hardware, doorstops, holder and bumper, floor or wall Ea.
08712 065 0100 Thresholds, aluminum, 8" wide x 1/2" thick Ea.
08712 065 2410 Threshold, aluminum, ADA, 7" wide x 72" long Ea.
08712 090 8000 Door hardware, hinge, install Pr.
08712 110 0400 Astragals, one piece overlapping, cadmium plated steel, flat, 3/16" x 2" L.F.
08811 010 0020 Float glass, clear, plain, 3/16" thick S.F.
08811 010 0200 Float glass, clear, tempered, 3/16" thick S.F.
08811 010 0600 Float glass, clear, plain, 1/4" thick S.F.
08811 010 0700 Float glass, tinted, 1/4" thick S.F.
08811 710 0030 Fire glass, mid range S.F.
08812 010 0020 Glass, full vision window system, 3/4" glass mullions, 10' high S.F.
08816 510 1000 Wire glass, polished wire, diamond, clear, 1/4" thick S.F.
08911 910 0020 Wall louvers, aluminum, with screen, residential, fixed, 8" x 8" Ea.
08911 910 0100 Wall louvers, aluminum, with screen, residential, fixed, 12" x 12" Ea.
08911 910 0200 Wall louvers, aluminum, with screen, residential, new, fixed, 12" x 18" Ea.
08911 910 0250 Wall louvers, aluminum, with screen, residential, new, fixed, 14" x 24" Ea.
08911 910 0300 Wall louvers, aluminum, with screen, residential, new, fixed, 18" x 24" Ea.
08911 910 0500 Wall louvers, aluminum, with screen, residential, new, fixed, 24" x 30" Ea.
09017 010 0140 Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, up to 2" square Ea.
09017 010 0150 Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 2" to 4" square Ea.
09017 010 0160 Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 4" to 8" square Ea.
09017 010 0170 Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 8" to 12" square Ea.
09017 010 0180 Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 12" to 32" square Ea.
09017 010 0210 Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 16" by 48" Ea.
09017 010 0220 Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 32" by 48" Ea.
09017 010 0230 Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 48" square Ea.
09017 010 0240 Gypsum wallboard, repairs, cut square, patch, sand and finish, holes, 60" square Ea.
09017 010 0500 Gypsum wallboard, repairs, skim coat surface with joint compound S.F.
09017 010 9000 Gypsum wallboard, repairs, minimum labor/equipment charge Job 09050 510 1200 Ceiling demolition, suspended ceiling, mineral fiber, 2 x 2 or 2 x 4, remove S.F.
09050 510 1250 Ceiling demolition, suspended ceiling, mineral fiber, on suspension system, remove S.F.
09050 510 9000 Ceiling demolition, minimum labor/equipment charge Job 09050 520 0400 Flooring demolition, carpet, bonded, includes surface scraping S.F.
09050 520 0480 Flooring demolition, custom carpet, heavy, tackless, remove and reset, includes surface scraping S.F.
09050 520 0550 Carpet tile, releasable adhesive, removal S.F.
09050 520 0800 Flooring demolition, resilient, sheet goods S.F.
09050 520 0850 Flooring demolition, vinyl or rubber cove base, straight section L.F.
09050 520 0900 Flooring demolition, vinyl composition tile, 12" x 12" S.F.
09050 520 2000 Flooring demolition, tile, ceramic, thin set S.F.
09050 520 8200 Flooring demolition, raised access floor S.F.
09050 520 9000 Flooring demolition, minimum labor/equipment charge Job 09050 530 0020 Walls and partitions demolition, concrete, reinforced C.F.
09050 530 0200 Walls and partitions demolition, concrete block, 4" thick S.F.
09050 530 0280 Walls and partitions demolition, concrete block, 8" thick, remove damaged blocks S.F.
09050 530 1000 Walls and partitions demolition, gypsum wallboard, per s.f., nailed or screwed S.F.
09050 530 2300 Walls and partitions demolition, metal or wood studs, finish two sides, plasterboard (gypsum wallboard) S.F.
09050 530 3760 Walls and partitions demolition, tile, ceramic, on walls, thin set S.F.
09050 530 3975 Selective demolition, demolish wire mesh panels S.F.
09050 530 5000 Walls and partitions demolition, wallcovering, vinyl S.F.
09050 530 5010 Walls and partitions demolition, wallcovering, vinyl, with release agent S.F.
09050 530 9000 Walls and partitions demolition, minimum labor/equipment charge Job 09221 313 1200 Furring, walls, on steel, galvanized, 7/8" channels, 16" OC S.F.
09221 613 1640 Metal stud partition, non-load bearing, galvanized, 8' high, 3-5/8" wide, 25 gauge, 16" OC, includes top & bottom track S.F.
09223 643 0100 Security mesh, expanded metal, flat, screwed to framing, on walls, 3/4", 1.76 lb/SF S.F.
09231 310 0300 Perlite or Vermiculite Plaster, 2 coats, on walls, excludes lath S.Y.
09232 010 0300 Gypsum plaster, 2 coats, on walls, lath excluded S.Y.
09291 030 0300 Gypsum wallboard, on walls, standard, 1/2" thick, finish excluded S.F.
09291 030 0390 Gypsum wallboard, on walls, standard, w/compound skim coat (level 5 finish), 1/2" thick S.F.
09291 030 2150 Gypsum wallboard, on walls, fire resistant, taped & finished (level 4 finish), 5/8" thick S.F.
09311 310 5110 Ceramic tile, pregrouted sheets, floors, unglazed, silicone grout, urethane adhesive, 4-1/4" x 4-1/4", 6" x 4-1/4", & 8-1/2" x 4-1/4", 2 s.f. sheets S.F.
09512 310 1110 Suspended acoustic ceiling tiles, mineral fiber tile, lay-in, fine texture, 2' x 2' or 2' x 4', 5/8" thick S.F.
09512 310 1125 Suspended acoustic ceiling tiles, mineral fiber tile, lay-in, fine texture, 2' x 2' or 2' x 4', 3/4" thick S.F.
09512 310 1135 Suspended acoustic ceiling tiles, mineral fiber tile, lay-in, fissured, 2' x 2' or 2' x 4', 3/4" thick S.F.
09512 310 1190 Suspended acoustic ceiling tiles, for fire rating, add S.F.
09512 310 9000 Suspended acoustic ceiling tiles, minimum labor/equipment charge Job 09512 330 0800 Complete suspended ceilings, mineral fiber, lay-in board, 2' x 2' x 3/4", on 15/16" T bar suspension, include standard suspension system, excl. 1-1/2" carrier channels S.F.
09512 330 0810 Complete suspended ceilings, mineral fiber, lay-in board, 2' x 4' x 5/8", on 15/16" T bar suspension, include standard suspension system, excl. 1-1/2" carrier channels S.F.
09641 910 0300 Wood composition flooring, for sanding and finishing, add S.F.
09651 313 0700 Wall base, vinyl, straight or cove, standard colors, 4" high, 1/8" thick L.F.
09651 313 0710 Wall base, vinyl, straight or cove, standard colors, 6" high, 1/8" thick L.F.
09651 313 1100 Wall base, rubber, straight or cove, standard colors, 4" high, 1/8" thick L.F.
09651 919 7000 Flooring, vinyl composition tile, 12" x 12" x 1/16" S.F.
09680 511 0107 Carpet transition strip, clamp down brass divider 12'/each (@vinyl to carpet) Ea.
09681 010 9000 Carpet, 20 oz./sq. yd., for tackless, stretched installation, add padding to above, sponge rubber pad S.Y.
09681 010 9300 Carpet pad, 32-56 oz./sq. yd., for tackless, stretched installation, add padding to above, felt S.Y.
09681 010 9800 Carpet pad, for 'double stick' installation, add S.Y.
09681 310 1100 Carpet tile, tufted nylon, 24 oz., 18" x 18" or 24" x 24" S.Y.
09681 310 1180 Carpet tile, tufted nylon, 35 oz., 18" x 18" or 24" x 24" S.Y.
09681 610 0700 Carpet, commercial grades, direct cement, nylon, level loop, 26 oz., light to medium traffic S.Y.
09681 610 0720 Carpet, commercial grades, direct cement, nylon, level loop, 28 oz., light to medium traffic S.Y.
09681 610 1100 Carpet, commercial grades, direct cement, nylon, level loop, 40 oz., medium to heavy traffic S.Y.
09681 610 3100 Carpet, commercial grades, direct cement, nylon, plush, 42 oz., medium to heavy traffic S.Y.
09681 610 3300 Carpet, commercial grades, direct cement, nylon, plush, 54 oz., heavy traffic S.Y.
09681 610 3340 Carpet, commercial grades, direct cement, nylon, plush, 60 oz., heavy traffic S.Y.
09681 610 5600 Carpet, for bound carpet baseboard, add L.F.
09681 610 9910 Carpet, minimum labor/equipment charge Job 09691 310 0250 Access floors, concrete fill panels, 2'x2', no finish S.F.
09721 613 3400 Wall coverings, vinyl, fabric-backed, heavyweight, type 3 (28 oz./S.Y.), incl. sizing S.F.
09721 910 0050 Textile wall coverings, blend, incl. sizing S.F.
09910 320 0510 Paint preparation, surface protection, placement & removal, basic drop cloths S.F.
09910 340 0080 Surface preparation, interior, doors, wire brush, metal, flush S.F.
09911 342 0330 Paints & coatings, misc. exterior, stair stringers, exterior, rough sawn wood, roll & brush, exterior latex, each coat, 4" x 12" L.F.
09911 370 0135 Paints & coatings, exterior door frames & trim only, brushwork, 2 coats, exterior latex, both sides Ea.
09911 370 0190 Paints & coatings, exterior doors, flush, both sides, roll & brush, primer + 2 coats, exterior latex, incl. frame & trim Ea.
09912 333 1200 Paints & coatings, interior, alkyd (oil base), flush door w/frame, 2 coats, brushwork, 3' x 7' Ea.
09912 333 1400 Paints & coatings, interior, alkyd (oil base), doors, flush, w/frame, both sides, stain, brushwork, wipe off, 3' x 7', excl. frame Ea.
09912 333 1800 Paints & coatings, interior, doors, flush, w/frame, both sides, varnish, brushwork, sand after 1st coat, 3' x 7', excl. frame Ea.
09912 335 0130 Paints & coatings, interior latex, doors, flush, both sides, roll & brush, primer + 1 coat, incl. frame & trim Ea.
09912 335 0510 Paints & coatings, interior latex, windows, per interior side, 1-6 lite, brushwork, primer + 2 coats, enamel, based on 15 SF Ea.
09912 352 6600 Paints & coatings, miscellaneous interior, radiators, per side, primer, brushwork S.F.
09912 352 7600 Paints & coatings, miscellaneous interior, trim, wood, paint 2 coats, oil base, brushwork, over 6" wide L.F.
09912 362 0400 Electrostatic painting, flat surfaces (lockers, casework, elevator doors, etc.), two coats, in shop S.F.
09912 372 0800 Paints & coatings, walls & ceilings, interior, concrete, drywall or plaster, latex paint, 2 coats, smooth finish, brushwork S.F.
09912 372 0880 Paints & coatings, walls & ceilings, interior, concrete, drywall or plaster, latex paint, 2 coats, smooth finish, spray S.F.
09912 374 0840 Paints & coatings, walls & ceilings, interior, concrete, drywall or plaster, zero voc latex, 2 coats, smooth finish, roller S.F.
09912 374 8200 Paints & coatings, walls & ceilings, interior, zero voc latex, for work 8'-15' high, add S.F.
09912 374 9900 Paints & coatings, walls & ceilings, interior, zero voc latex, minimum labor/equipment charge Job 09932 310 0020 Paints & coatings, varnish 1 coat + sealer, on wood trim, brush, incl. no sanding, no VOC S.F.
10144 310 0111 Photoluminescent exit sign, directional, plastic, 10"x14" Ea.
10221 943 1200 Partitions, movable office, demountable gypsum system, vinyl-clad, 2" - 2-1/2" steel studs, 9' h x 3"- 3-3/4" thick, excludes doors; do not deduct door openings from total LF L.F.
10572 319 1000 Wood shelving, bookcase, clear grade pine, 12" deep, shelves 12" OC S.F.
10572 319 9000 Wood shelving, minimum labor/equipment charge Job 12050 510 7400 Selective demolition, office furniture systems S.F.
21121 350 9900 Fire hose & equipment, minimum labor/equipment charge Job 21131 350 5620 Sprinkler system components, sprinkler heads, concealed, complete with coverplate, 135-212 degrees F, 1/2" NPT, 1/2" orifice, excludes supply piping Ea.
22050 510 1400 Fixture, water closet, floor mounted, selective demolition, includes 10' piping Ea.
22050 510 1420 Fixture, water closet, wall mounted, selective demolition Ea.
22050 510 1600 Fixture, water fountain, free standing, remove, includes 10' piping Ea.
22050 510 2000 Pipe, metal pipe, to 1-1/2" diam., selective demolition L.F.
22050 510 2050 Pipe, metal pipe, 2" to 3-1/2" diam., selective demolition L.F.
22050 510 2100 Pipe, metal pipe, 4" to 6" diam., selective demolition L.F.
22050 510 9300 Vent flashing or vent caps, selective demolition Ea.
22052 360 3240 Valves, plastic, PVC, ball check, socket or threaded, 1/2" Ea.
22052 360 3250 Valves, plastic, PVC, ball check, socket or threaded, 3/4" Ea.
22052 360 3260 Valves, plastic, PVC, ball check, socket or threaded, 1" Ea.
22052 360 3270 Valves, plastic, PVC, ball check, socket or threaded, 1-1/4" Ea.
22052 360 3280 Valves, plastic, PVC, ball check, socket or threaded, 1-1/2" Ea.
22052 360 3290 Valves, plastic, PVC, ball check, socket or threaded, 2" Ea.
22071 910 6860 Insulation, pipe covering (price copper tube one size less than I.P.S.), fiberglass with all service jacket, 1" wall, 3/4" iron pipe size L.F.
22071 910 6870 Insulation, pipe covering (price copper tube one size less than I.P.S.), fiberglass with all service jacket, 1" wall, 1" iron pipe size L.F.
22071 910 6880 Insulation, pipe covering (price copper tube one size less than I.P.S.), fiberglass with all service jacket, 1" wall, 1-1/4" iron pipe size L.F.
22071 910 6890 Insulation, pipe covering (price copper tube one size less than I.P.S.), fiberglass with all service jacket, 1" wall, 1-1/2" iron pipe size L.F.
22071 910 6900 Insulation, pipe covering (price copper tube one size less than I.P.S.), fiberglass with all service jacket, 1" wall, 2" iron pipe size L.F.
22071 910 8445 Insulation, pipe covering (price copper tube one size less than I.P.S.), rubber tubing flexible closed cell foam, 1" wall, 3/4" iron pipe size L.F.
22071 910 8446 Insulation, pipe covering (price copper tube one size less than I.P.S.), rubber tubing flexible closed cell foam, 1" wall, 1" iron pipe size L.F.
22071 910 8447 Insulation, pipe covering (price copper tube one size less than I.P.S.), rubber tubing flexible closed cell foam, 1" wall, 1-1/4" iron pipe size L.F.
22071 910 8448 Insulation, pipe covering (price copper tube one size less than I.P.S.), rubber tubing flexible closed cell foam, 1" wall, 1-1/2" iron pipe size L.F.
22071 910 8449 Insulation, pipe covering (price copper tube one size less than I.P.S.), rubber tubing flexible closed cell foam, 1" wall, 2" iron pipe size L.F.
22111 323 1140 Pipe, copper, tubing, solder, 1/2" diameter, type K, includes coupling & clevis hanger assembly 10' OC L.F.
22111 323 1180 Pipe, copper, tubing, solder, 3/4" diameter, type K, includes coupling & clevis hanger assembly 10' OC L.F.
22111 323 1200 Pipe, copper, tubing, solder, 1" diameter, type K, includes coupling & clevis hanger assembly 10' OC L.F.
22111 323 1220 Pipe, copper, tubing, solder, 1-1/4" diameter, type K, includes coupling & clevis hanger assembly 10' OC L.F.
22111 325 9000 Pipe fittings, copper, minimum labor/equipment charge Job 22111 348 1080 Pipe, fittings & valves, steel, black, grooved joint, 2" diameter, schedule 40, incl coupling & clevis type hanger 10' OC L.F.
22111 914 3440 Flexible metal hose, metal stainless steel braid, over corrugated stainless steel flanged ends, 150 psi, 1-1/2" diameter x 12" Ea.
22131 620 4100 Pipe, cast iron soil, no hub, 1-1/2" diameter, includes couplings 10' OC, clevis hanger assemblies 5' OC L.F.
22131 620 4120 Pipe, cast iron soil, no hub, 2" diameter, includes couplings 10' OC, clevis hanger assemblies 5' OC L.F.
22131 620 4140 Pipe, cast iron soil, no hub, 3" diameter, includes couplings 10' OC, clevis hanger assemblies 5' OC L.F.
22131 620 4160 Pipe, cast iron soil, no hub, 4" diameter, includes couplings 10' OC, clevis hanger assemblies 5' OC L.F.
22131 630 8340 Coupling (by MG), cast iron soil, no hub, cast iron clamp and neoprene gasket, 4" Ea.
22131 660 1150 Traps, cast iron, service weight, running P trap, 4", excluding vent Ea.
22131 660 3000 Traps, cast iron, service weight, P trap, B&S, 2" pipe size Ea.
22411 344 0150 Toilet seat, molded composition, white, industrial, open front, regular bowl, excludes cover Ea.
22411 344 0520 Toilet seat, molded composition, white, self-raising hinge, open front, regular bowl, excludes cover Ea.
22411 613 4120 Lavatory, wall hung, porcelain enamel on cast iron, white, single bowl, 19" x 17", includes trim Ea.
22411 613 6960 Lavatory, wall hung, rough-in, supply, waste and vent Ea.
22413 910 8200 Faucets/fittings, water supply stops, polished chrome plate, angle, 3/8" Ea.
22421 313 3100 Water closet, bowl only, wall hung, includes flush valve and seat Ea.
22421 313 3200 Water closet, bowl only, wall hung, rough-in, supply, waste and vent Ea.
22421 313 3350 Water closet, bowl only, floor mounted, tankless, with wall outlet, includes flush valve and seat Ea.
22421 313 3370 Water closet, bowl only, floor mounted, tankless, rough-in, supply, waste and vent Ea.
22423 910 0900 Faucets/fittings, flush valve, tankless water closet, concealed rear spud, wall hung Ea.
22423 910 0972 Faucets/fittings, flush valve, automatic flush sensor and operator for urinals or waterclosets, standard Ea.
22423 910 2800 Faucets/fittings, lavatory faucet, self-closing center set, commercial Ea.
22423 910 2810 Faucets/fittings, lavatory faucet, automatic sensor and operator, with faucet head, commercial Ea.
22423 910 3000 Faucets/fittings, service sink faucet, cast spout, pail hook, hose end Ea.
22423 930 4800 Carriers/supports, sink, floor mounted, exposed arm system, back to back standard fixtures Ea.
22423 930 7040 Carriers/supports, water closet, siphon jet, horizontal, adjustable, caulk, single, 4" pipe size Ea.
22471 310 2820 Drinking fountain, wall mounted, non-recessed, stainless steel, dual level, ADA compliant, single bubbler, for connection to cold water supply Ea.
23050 510 9000 HVAC, selective demolition, minimum labor/equipment charge Job 23071 310 3160 Duct thermal insulation, blanket type, fiberglass, flexible, FSK vapor barrier wrap, .75 lb. density, 1" thick S.F.
23071 310 3180 Duct thermal insulation, blanket type, fiberglass, flexible, FSK vapor barrier wrap, .75 lb. density, 2" thick S.F.
23092 310 5010 Control components/DDC system, communications bus (data transmission cable), #18 twisted shielded pair in 1/2" EMT conduit C.L.F.
23095 310 5230 Control component, thermostats, electric, low voltage, 3 wire Ea.
23095 310 5320 Control component, transmitter, pneumatic, temperature averaging element Ea.
23311 313 0500 Metal ductwork, fabricated rectangular, galvanized steel, under 200 lb., incl fittings, joints, supports & allow for a flexible connections field sketches, excludes as-built drawings and insulation Lb.
23311 313 0520 Metal ductwork, fabricated rectangular, galvanized steel, 200 to 500 lb., incl fittings, joints, supports & allow for a flexible connections field sketches, excludes as-built drawings and insulation Lb.
23311 313 0540 Metal ductwork, fabricated rectangular, galvanized steel, 500 to 1000 lb., incl fittings, joints, supports & allow for a flexible connections field sketches, excludes as-built drawings and insulationLb.
23311 313 0560 Metal ductwork, fabricated rectangular, galvanized steel, 1000 to 2000 lb., incl fittings, joints, supports & allow for a flexible connections field sketches, excludes as-built drawings and insulationLb.
23311 319 2000 Duct accessories, fabrics for flexible connections, with metal edge L.F.
23311 613 9990 Fibrous glass ductwork, AC& ventilation, minimum labor/equipment charge Job 23331 313 7522 Duct accessories, variable volume modulating motorized damper, 12" x 16", includes electric motor Ea.
23331 316 3200 Duct accessories, fire damper, curtain type, vertical, 24" x 12", UL label, 1-1/2 hour rated Ea.
23334 610 1940 Ductwork, flexible coated fiberglass fabric on corrosion resistant metal helix, insulated, P.E. jacket, 1" thick, 6" diameter, pressure to 12"(WG) UL-181 L.F.
23334 610 2000 Ductwork, flexible coated fiberglass fabric on corrosion resistant metal helix, insulated, P.E. jacket, 1" thick, 9" diameter, pressure to 12"(WG) UL-181 L.F.
23334 610 2040 Ductwork, flexible coated fiberglass fabric on corrosion resistant metal helix, insulated, P.E. jacket, 1" thick, 12" diameter, pressure to 12"(WG) UL-181 L.F.
23335 310 3344 Insulation, ductwork, board type, fiberglass liner, FSK, 1-1/2 lb. density, 1" thick S.F.
23335 310 3346 Insulation, ductwork, board type, fiberglass liner, FSK, 1-1/2 lb. density, 2" thick S.F.
23361 610 5510 Duct accessories, mixing box, variable air volume, cool only, pneumatic pressure independent, 500 to 1,000 CFM, includes electric or pneumatic motor Ea.
23361 610 5530 Duct accessories, mixing box, variable air volume, cool only, pneumatic pressure independent, 1,100 to 2,000 CFM, includes electric or pneumatic motor Ea.
23361 610 5550 Duct accessories, mixing box, variable air volume, cool only, pneumatic pressure independent, 2,000 to 4,000 CFM, includes electric or pneumatic motor Ea.
23371 310 0500 Diffuser, aluminum, ceiling, perforated, 24" x 24" lay-in panel size, 6" x 6", includes opposed blade damper Ea.
23371 310 0620 Diffuser, aluminum, ceiling, perforated, 24" x 24" lay-in panel size, 24" x 24", includes opposed blade damper Ea.
23371 310 1560 Diffuser, steel, ceiling, round, 12" diameter, includes butterfly damper Ea.
23371 330 0380 Grille, aluminum, air supply, adjustable, single deflection, 24" x 24" Ea.
23371 330 4040 Grille, aluminum, eggcrate, framed, 24" x 24" opening Ea.
23371 360 4080 Register, air supply, floor, enameled steel, 6" x 14", includes toe operated damper Ea.
26015 081 0962 Fluorescent troffer new replacement lens, 2' x 2', remove and install Ea.
26015 081 0964 Fluorescent troffer new replacement lens, 2' x 4', remove and install Ea.
26050 510 0200 Conduit, electric metallic tubing (EMT), 1/2" to 1" diameter, electrical demolition, remove conduit to 10' high, including fittings & hangers L.F.
26050 510 0220 Conduit, electric metallic tubing (EMT), 1-1/4" to 1-1/2" diameter, electrical demolition, remove conduit to 10' high, including fittings & hangers L.F.
26050 510 0240 Conduit, electric metallic tubing (EMT), 2" to 3" diameter, electrical demolition, remove conduit to 10' high, including fittings & hangers L.F.
26050 510 0260 Conduit, electric metallic tubing (EMT), 3-1/2" to 4" diameter, electrical demolition, remove conduit to 10' high, including fittings & hangers L.F.
26050 510 0310 Armored cable, (BX), #12, 3 wire, average 50' runs, electrical demolition, remove L.F.
26050 510 0370 Non metallic sheathed cable, (Romex), #14, 3 wire, electrical demolition, remove L.F.
26050 510 0390 Non metallic sheathed cable, (Romex), #10, 3 wire, electrical demolition, remove L.F.
26050 510 0465 Wiremold raceway, telephone/power pole, electrical demolition, remove Ea.
26050 510 1780 Receptacle & switch plates, electrical demolition, remove Ea.
26050 510 1790 Receptacle & switches, 15 to 30 amp, electrical demolition, remove Ea.
26050 510 1860 Wire, THW-THWN-THHN, #8, electrical demolition, removed from in place conduit, to 15' high C.L.F.
26050 510 2140 Fluorescent fixtures, interior, 4 lamp, 2' x 4', electrical demolition, remove, recessed drop-in, to 15' high, including supports & whips Ea.
26050 520 3210 Undercarpet, power or telephone, flat cable, electrical demolition, remove L.F.
26050 520 6000 Floor box and carpet flange, electrical demolition, remove Ea.
26050 520 6310 Wireway, to 10' high, 2-1/2" x 2-1/2", electrical demolition, remove, incl fittings and supports L.F.
26050 520 7008 Receptacle, explosion proof, 120 V, to 30 A, electrical demolition, remove Ea.
26050 550 3010 Metal light pole, 10' high, electrical demolition, remove, excludes concrete bases Ea.
26050 550 4200 Fluorescent fixture, explosionproof, electrical demolition, remove Ea.
26050 550 5000 Ballast, fluorescent fixture, electrical demolition, remove Ea.
26050 550 5310 Exit light, electrical demolition, remove Ea.
26050 550 5320 Emergency battery pack lighting unit, electrical demolition, remove Ea.
26051 920 9240 Metal clad cable, copper, aluminum clad, 600 volt, 3 wire, #12 C.L.F.
26051 990 0940 Wire, copper, solid, 600 volt, #12, type THWN-THHN, normal installation conditions in wireway, conduit, cable tray C.L.F.
26051 990 1200 Wire, copper, stranded, 600 volt, #12, type THWN-THHN, normal installation conditions in wireway, conduit, cable tray C.L.F.
26051 990 1250 Wire, copper, stranded, 600 volt, #10, type THWN-THHN, normal installation conditions in wireway, conduit, cable tray C.L.F.
26051 990 1300 Wire, copper, stranded, 600 volt, #8, type THWN-THHN, normal installation conditions in wireway, conduit, cable tray C.L.F.
26051 990 9000 Wire, minimum labor/equipment charge Job 26053 313 1770 Rigid galvanized steel conduit, 3/4" diameter, to 10' H, incl 2 terminations, 2 elbows, 11 beam clamps, and 11 couplings per 100 LF L.F.
26053 313 2500 Intermediate metal conduit, 1/2" diameter, to 10' high, incl 2 terminations, 2 elbows, 11 beam clamps, and 11 couplings per 100 LF L.F.
26053 313 5020 Electric metallic tubing (EMT), 3/4" diameter, to 10' high, incl 2 terminations, 2 field bend elbows, 11 beam clamps, and 11 couplings per 100 LF L.F.
26053 316 0020 Outlet boxes, pressed steel, 4" octagon Ea.
26053 316 0060 Outlet boxes, pressed steel, covers, blank, 4" octagon Ea.
26053 316 0150 Outlet boxes, pressed steel, 4" square Ea.
26053 316 0250 Outlet boxes, pressed steel, covers, blank, 4" square Ea.
26053 316 0300 Outlet boxes, pressed steel, plaster rings, 4" square, concealed Ea.
26092 310 0110 Lighting devices, occupancy sensors, ultrasonic, ceiling mounted Ea.
26092 310 0120 Lighting devices, occupancy sensors, dual technology, ceiling mounted Ea.
26241 620 0300 Circuit breakers, bolt-on, 10 k A I.C., 1 pole, 120 volt, 70 amp Ea.
26241 620 0600 Circuit breakers, bolt-on, 10 k A I.C., 2 pole, 240 volt, 80-100 amp Ea.
26241 620 0900 Circuit breakers, bolt-on, 10 k A I.C., 3 pole, 240 volt, 80-100 amp Ea.
26272 340 0100 Surface raceway, metal, straight section, no. 500 L.F.
26272 340 0670 Surface raceway, metal, straight section, base & cover, blank, no. 2400 L.F.
26272 340 4120 Surface raceway, tele-power pole, aluminum, w/ 2 receptacle, 12' Ea.
26272 620 0500 Toggle switch, quiet type, single pole, 20 amp Ea.
26272 620 0800 3 way switch, 20 amp Ea.
26272 620 1000 4 way switch, 20 amp Ea.
26272 620 2470 Duplex receptacle, grounded, 120 volt, 20 amp Ea.
26272 620 2480 Duplex receptacle, ground fault interrupting, 15 amp Ea.
26272 620 3600 Receptacle, 20 amp, 250 volt, NEMA 6 Ea.
26272 620 5160 Plug, 30 amp, 125 volt, NEMA 5 Ea.
26281 610 0600 Circuit breaker, 3 pole, 600 volt, 225 amp, enclosed (NEMA 1) Ea.
26281 620 2910 Safety switches, heavy duty, 3 pole, fusible, 240 volt, 30 amp, NEMA 1 Ea.
26511 350 0300 Fluorescent fixture, interior, acrylic lens, grid recess ceiling mounted, 2-U40 W, 2' W x 2' L, incl lamps, mounting hardware and connections Ea.
26511 350 0500 Fluorescent fixture, interior, acrylic lens, grid recess ceiling mounted, 3-40 W, 2' W x 4' L, incl lamps, mounting hardware and connections Ea.
26511 350 0800 Fluorescent fixture, interior, acrylic lens, grid recess ceiling mounted, 6-40 W, 4'W x 4'L, incl lamps, mounting hardware and connections Ea.
26511 350 1700 Fluorescent fixture, interior, surface mounted, acrylic lens, 6-40 W, 4' W x 4' L, incl lamps, mounting hardware and connections Ea.
26511 350 3510 Fluorescent fixture, interior, troffer parabolic lay-in, 1-32 W T8, 1' W x 4' L, incl lamps, mounting hardware and connections Ea.
26511 350 3525 Fluorescent fixture, interior, troffer parabolic lay-in, 2-U32 W T8, 2' W x 2' L, incl lamps, mounting hardware and connections Ea.
26511 350 3530 Fluorescent fixture, interior, troffer parabolic lay-in, 3-32 W T8, 2' W x 4' L, incl lamps, mounting hardware and connections Ea.
26511 350 4500 Incandescent fixture, interior, high hat can, round alzak reflector, prewired, 300 W, incl lamps, mounting hardware and connections Ea.
26511 350 7640 Dimmable ballast, replacement, interior lighting fixtures, one-lamp, to 15' high Ea.
26511 350 7650 Dimmable ballast, replacement, interior lighting fixtures, two-lamp, to 15' high Ea.
26511 350 7660 Dimmable ballast, replacement, interior lighting fixtures, three-lamp, to 15' high Ea.
26511 350 9000 Interior lighting fixtures, minimum labor/equip charge Job 26521 310 0500 Emergency lighting units, lead battery operated, twin sealed beam light, 25 W, 6 V each Ea.
26521 316 0080 Exit lighting, incandescent, single face, ceiling or wall mount Ea.
26612 310 0125 Fluorescent lamp, rapid start, cool white, energy saver, 25 watt, 3' long C 27050 520 0220 Voice/data outlet, electrical demolition, remove Ea.
27151 313 2300 Telephone cable, telephone twisted, PVC insulation, #22-4 conductor C.L.F.
27151 313 7000 Unshielded twisted pair (UTP) cable, solid, PVC jacket, #24, 4 pair, category 5 C.L.F.
27151 313 7242 Unshielded twisted pair (UTP) cable, solid, plenum, #24, 4 pair, category 6 C.L.F.
27151 313 7401 Voice/data expansion module, modular jack,cat 6 keystone,RJ45, office white, cat 6 keystone,RJ45, office white Ea.
27154 313 1020 Voice/data wall plate, plastic, 1 gang, 2-port, excl voice/data devices Ea.
27154 313 1140 Voice/data wall plate, stainless steel, 1 gang, 2-port, excl voice/data devices Ea.
28050 510 1060 Video camera, electrical demolition, remove Ea.
28050 510 1130 Video monitor, 19", electrical demolition, remove Ea.
28050 510 1210 Fire alarm horn and strobe light, electrical demolition, remove Ea.
28050 510 1220 Flame detector, electrical demolition, remove Ea.
28050 510 1240 Smoke detector, electrical demolition, remove Ea.
28050 510 1250 Fire alarm pull station, electrical demolition, remove Ea.
28050 510 1260 Fire alarm control panel, 4 to 8 zone, electrical demolition, remove Ea.
28050 510 1280 Fire alarm annunciation panel, 4 to 8 zone, electrical demolition, remove Ea.
28151 111 0700 Access control equipment, entrance card reader, barium ferrite Ea.
28231 310 2000 Closed circuit television system (CCTV), surveillance, one station (camera & monitor) Total 28411 550 9410 Radiation monitoring systems, minimum labor/equipment charge Job 28461 127 5240 Detection system, smoke detector, addressable type, excl. wires & conduit Ea.
28461 150 5010 Detection system, fire alarm, detector, heat (addressable type), excl. wires & conduit Ea.
28462 150 4160 Detection system, fire alarm control panel, addressable without voice, up to 200 points, excluding wires & conduits Ea.
28462 150 4600 Detection system, UPS battery charger, signal bell, excluding wires & conduits Ea.
28462 150 4610 Detection system, fire alarm signal bell 10" red 20-24 V P Ea.
28462 150 4800 Detection system, signal bell for fire alarm, trouble buzzer or manual station, excluding wires & conduits Ea.
28462 150 5600 Detection system, strobe & horn, excluding wires & conduits Ea.
28462 150 5610 Detection system, strobe & horn, ADA type, excluding wires & conduits Ea.
28462 150 5800 Detection system, fire alarm horn, excluding wires & conduits Ea.
28462 150 7800 Detection system, remote annunciator, 8 zone lamp, excluding wires & conduits Ea.
34711 317 2700 Security vehicle barriers, pipe bollards, steel, concrete filled/painted, 8' L x 4' D hole, 8" diam. Ea.
| Express Menu title page |
| 47PK0120R0003 Express Menu list |
File details come from the government source that posted it. Updated .