Exhibit 6 COOS BAY OFFICE REMODEL PLANS.pdf
PDF 1 MB Posted
- Attached to
- Coos Bay Office Building Remodel
- Solicitation number
- S-73000-00017193
- Issued by
- Coos County, Condon City, Oregon
About this file
Coos Bay Office Building Remodel Project
This is a set of architectural and construction plans for the Oregon Department of Transportation (ODOT) Coos Bay Office Building Remodel located at 1155 South 5th Street, Coos Bay, Oregon 97420. The project involves selective demolition and construction of improvements to a 7,488-square-foot building that houses ODOT District 7 offices and a Department of Motor Vehicles (DMV) service area. The scope of work includes constructing new ADA-compliant unisex restrooms, installing new electrical receptacles and data ports, relocating ceiling-mounted lighting and HVAC components, framing new walls and offices, installing a new transaction window counter for customer service, replacing gypsum board with mold-resistant alternatives in the restroom areas, and replacing carpeting. The project encompasses demolition of existing walls and demountable modular partitions, relocation of server room equipment and data infrastructure, and comprehensive updates to electrical, plumbing, and HVAC systems. The contractor is responsible for obtaining all required permits and providing as-constructed drawings upon completion.
The project plans specify that all work shall conform to applicable Oregon codes and local jurisdiction requirements, including the Oregon Plumbing Specialty Code and Oregon Electrical Specialty Code. All plumbing work must be performed by a licensed plumber and electrical work by a licensed electrician. The contractor is required to conduct a pre-bid site visit to examine existing conditions and must submit any discrepancies or clarifications in writing prior to installation. Material specifications include PEX-A piping with brass fittings for plumbing, copper conductors for electrical work, and mold-resistant gypsum board in restroom areas. The plans designate specific components as either contractor-supplied or to be provided by ODOT or others, with substitution requests requiring prior written approval from the ODOT Construction Project Manager. Upon project completion, the contractor must clean the entire work area to the satisfaction of the project manager.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WALLOWA
UNION
UMATILLA
MORROW
GILLIAM
SHERMANWASCO
HOOD
RIVER
CLACKAMAS
MULTNOMAH
COLUMBIA
CLATSOP
TILLAMOOK
WASHINGTON
YAMHILL
POLK
LINCOLN
BENTON
LINN
MARION
LANE
DOUGLAS
COOS
CURRY
JOSEPHINE
JACKSON
KLAMATH
LAKE
HARNEY
MALHEUR
CROOK
JEFFERSON WHEELER
GRANT
BAKER
DESCHUTES
26 JOHN
DAY
THE
DALLES
PENDLETON
LA
GRANDE
BAKER
CITY
ONTARIO
BURNS
BEND
KLAMATH
FALLS
PORTLAND
SALEM
EUGENE
ROSEBURG
MEDFORD
COOS
BAY
NEWPORT
ASTORIA
FLORENCE
CORVALLIS
ALBANY
ASHLAND
LAKEVIEW
O H
P O
H P
O H
P
O H
P O
H P
O H
P O
H P
O H
P O
H P
OHPOHPOHPOHPOHPOHP OHP OHP OHP OHP OHP
O H
PW LOCKHART AVE
S 5t h
ST
ODOT OFFICE
AND DMV
KRUSE AVE
S 7t h
ST
O H
P
OHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHP
OHP
OHP
BLDG C
F4060908
BLDG A
F4060903
BLDG B
F4060904
GENERATOR ROOM
F4060902
258'
258'
151' 151'
516'
302'
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4060901
ODOT COOS BAY
OFFICE BUILDING REMODEL
1155 S 5th ST, COOS BAY, OR 97420 13 06/09/26
FRANCO
FRANCO
MIKE SCHWEIZER
MIKE SCHWEIZER
ODOT COOS BAY
OFFICE BUILDING
REMODEL
1155 S 5TH ST, COOS BAY, OR 97420
OCCUPANCY: B
CONSTRUCTION TYPE: 5-B
FIRE SPRINKLERS: NOT PROVIDED
ACTUAL BUILDING AREA: 7,488 SF
OCCUPANT LOAD: 1 PER 150 SF = 50
AREA OF DMV SERVICE AREA (PUBLIC AREA) : 876 SF
OCCUPANT LOAD OF DMV = 6
ZONING = 1-C
BUILDING USE = DEPARTMENT OF MOTOR VEHICLES OFFICE
DEPARTMENT OF TRANSPORTATION DISTRICT 7 OFFICE
CODE DATA:
1. ALL WORK SHALL CONFORM TO APPLICABLE CODES, LAWS AND
ORDINANCES OF THE JURISDICTION HAVING AUTHORITY.
2. DO NOT SCALE THE DRAWINGS.
3. DRAWINGS ARE SCHEMATIC IN NATURE, MAJOR COMPONENTS AND
EQUIPMENT ARE SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL
SUPPLY AND INSTALL ALL MINOR COMPONENTS AND MATERIALS
NECESSARY TO PROVIDE A COMPLETE AND FUNCTIONAL PROJECT
WHETHER ALL SUCH COMPONENTS ARE NOTED IN THE DRAWINGS AND
SPECIFICATIONS.
4. THE CONTRACTOR SHALL MAKE A SITE VISIT AND EXAMINE EXISTING
CONDITIONS PRIOR TO PROVIDING A BID. ANY DISCREPANCIES SHALL BE
BROUGHT TO THE ATTENTION OF ODOT THROUGH A REQUEST FOR
CLARIFICATION AS SET FORTH IN THE BID DOCUMENTS.
5. CLARIFICATIONS SHALL BE REQUESTED IN WRITING PRIOR TO ANY
INSTALLATION. INCORRECT INSTALLATIONS SHALL BE CORRECTED AT NO
ADDITIONAL COST TO ODOT.
6. ALL WORK SHOWN IS TO BE BY THE CONTRACTOR UNLESS SPECIFICALLY
NOTED AS BEING BY ODOT OR BY OTHERS. ALL MATERIALS SHOWN ARE TO
BE PROVIDED BY THE CONTRACTOR UNLESS SPECIFICALLY NOTED AS
EXISTING OR PROVIDED BY ODOT.
7. PLANS AND SPECIFICATIONS CALL OUT SPECIFIC MAKES AND MODELS OF
EQUIPMENT IN SOME LOCATIONS. SUBSTITUTION REQUESTS SHALL BE
MADE DURING THE BID PROCESS. ODOT SHALL AT ITS SOLE DISCRETION
DETERMINE THE ACCEPTABILITY OF SUBSTITUTIONS. NO SUBSTITUTIONS
SHALL BE INSTALLED WITHOUT PRIOR WRITTEN APPROVAL FROM THE
ODOT CONSTRUCTION PROJECT MANAGER.
8. CLEAN ENTIRE WORK AREA AT CONCLUSION OF PROJECT TO THE
SATISFACTION OF THE ODOT PROJECT MANAGER.
GENERAL CONSTRUCTION NOTES
T101 TITLE SHEET
C101 EXISTING SITE PLAN
A101 EXISTING / DEMOLITION FLOOR PLAN
A102 LIGHTING / POWER DEMOLITION PLAN
A103 FLOOR PLAN
A104 ENLARGED AREA #1 AND #2
A105 ENLARGED AREA #3 AND INTERIOR ELEVATIONS
A106 REFLECTED CEILING AND POWER PLAN
A107 DETAILS
A108 DETAILS
A109 DOOR AND HARDWARE SCHEDULE
A110 INTERIOR FINISH SCHEDULE
A111 FURNITURE PLAN
SHEET INDEX
STATE VICINITY MAP
SCALE: N.T.S.
TITLE SHEET T101
COOS BAY
0 40'
25S1335 CB 11800 SITE PLAN
SCALE: 1" = 40'
PROJECT LOCATION
PROJECT SITE LOT / PARCEL
25S1335 CB 11800
O H
P O
H P
O H
P O
H P
O H
P
O H
P O
H P
O H
P O
H P
O H
P O
H P
O H
P O
H P
O H
P O
H P
O H
P O
H P
OHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP
O H
P
W LOCKHART AVE
S 5t h
ST
ODOT OFFICE
AND DMV
S 7t h
ST
GENERATOR ROOM
F4060902
ANTENNA
EXISTING ACCESS RAMP
EXISTING
ADA
PARKING
ROOF LINE
GRAVEL AREA
APPROXIMATE
PROPERTY LINE, TYP
258'
258'
151' 151'
516'
302'
10 11
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4060901
ODOT COOS BAY
OFFICE BUILDING REMODEL
1155 S 5th ST, COOS BAY, OR 97420 13 06/09/26
FRANCO
FRANCO
MIKE SCHWEIZER
MIKE SCHWEIZER
0 20'
EXISTING SITE PLAN
SCALE: 1" = 20'
EXISTING SITE PLAN C101
PARKING - GOVERNMENT BUILDINGS: 1 SPACE PER 330 SF.
7,488 SF = 23 PARKING SPACES REQUIRED
ADA SPACES = 2
EXISTING SPACES = 32
TOTAL SPACES = 34
DMV
OFFICE
113A
DMV
STORAGE
113D
STORAGE ROOM
113E
RECEPTION
113A
STORAGE
106A
ENTRY
HALLWAY
WOMENS
MENS
HALLWAY
DMV
BREAK
ROOM
HALLWAY
ODOT
BRIDGE
COORDINATOR
111C
UTILITY
ROOM
ODOT
CONFERENCE
ROOM
BLDG.
ENTRY
DMV
CUSTOMER
SERVICE
AREA
STORAGE
ROOM
110A
SUPPORT
STAFF
110B
OFFICE
ENTRY
ODOT
BREAK
ROOM
ODOT
BRIDGE
MGR
103A
SERVER
108A
ODOT
BRIDGE
OFFICE
OFFICE
OFFICE
111A
OFFICE
111B
ODOT
BRIDGE
CREW
DMV
OFFICE
113B
DMV
OFFICE
113C
DATA ROOM
±1'-6"
3'-0"
2'-0"
T
EXISTING FLOOR
VENTS, TYP.
48'-0" 12'-0" 48'-0" 108'-0"
6'-0"
6'-0"
24'-0"
6'-0"
42'-0"
72'-0"
42'-0"
6'-0"
24'-0"
72'-0"
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4060901
ODOT COOS BAY
OFFICE BUILDING REMODEL
1155 S 5th ST, COOS BAY, OR 97420 13 06/09/26
FRANCO
FRANCO
MIKE SCHWEIZER
MIKE SCHWEIZER
EXISTING / DEMOLITION FLOOR PLAN A101
EXISTING / DEMOLITION FLOOR PLAN
SCALE: 3/16" = 1'-0"
DEMOLITION KEYED NOTES:
1. DEMO EXISTING WALL AS SHOWN TO INSTALL NEW
WINDOW.
2. DEMO EXISTING DEMOUNTABLE WALL AND SALVAGE
FOR REINSTALLATION WHERE APPLICABLE.
3. REMOVE EXISTING WALL AND DOOR AS SHOWN.
4. DEMO EXISTING WALL AS REQUIRED FOR NEW
DOOR INSTALLATION.
5. DEMO EXISTING DEMOUNTABLE WALL AND DOOR AS
SHOWN. SALVAGE EXISTING DOOR FOR
REINSTALLATION.
6. OTHERS TO REMOVE ALL WIRING AND DATA RACK IN
SERVER ROOM FOR RELOCATION.
7. REMOVE AND SALVAGE EXISTING THERMOSTAT FOR
RELOCATION.
8. REMOVE EXISTING FLOOR VENTS AND SALVAGE
FOR RELOCATION.
9. LOCATE DUST CONTROL BARRIER.
10. REMOVE CARPETING IN AREA OF FUTURE
RESTROOM.
E
9'-0"
8'-0"
STORAGE
106A
ENTRY
HALLWAY
WOMENS
MENS
UTILITY
ROOM
ODOT
CONFERENCE
ROOM
B E
STORAGE
ROOM
110A
SUPPORT
STAFF
110B
OFFICE
ODOT
BREAK
ROOM
ODOT
BRIDGE
MGR
103A
SERVER
108A
ODOT
BRIDGE
OFFICE
OFFICE
T
T
EXISTING
THERMOSTAT, TYP.
EXISTING ELECTRICAL
RECEPTACLE, TYP.
EXISTING DATA
DROP,TYP.
EXISTING ELECTRICAL
SWITCH, TYP.
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4060901
ODOT COOS BAY
OFFICE BUILDING REMODEL
1155 S 5th ST, COOS BAY, OR 97420 13 06/09/26
FRANCO
FRANCO
MIKE SCHWEIZER
MIKE SCHWEIZER
LIGHTING / POWER DEMOLITION PLAN A102
DEMOLITION REFLECTED CEILING PLAN
SCALE: 3/16" = 1'-0"
DEMOLITION POWER PLAN
SCALE: 3/16" = 1'-0"
DEMOLITION KEYED NOTES:
1. REMOVE LIGHT FIXTURE AND SALVAGE FOR REINSTALLATION.
2. REMOVE EXISTING SUSPENDED CEILING GRID FOR NEW
RESTROOM FRAMING. REMOVE AS REQUIRED.
3. RELOCATE RETURN HVAC CEILING VENT.
REMOVE ALL
ELECTRICAL ITEMS
SHOWN DASHED
AND SHADED BACK
DMV
OFFICE
113A
DMV
STORAGE
113D
STORAGE
ROOM
113E
RECEPTION
113A
STORAGE
ENTRY HALLWAY
WOMENS
MENS
HALLWAY
DMV BREAK
ROOM
HALLWAY
ODOT
BRIDGE
COORDINATOR
111C
UTILITY
ROOM
NEW OPEN
OFFICE
BLDG.
ENTRY
DMV CUSTOMER
SERVICE AREA
STORAGE /
SERVER
OFFICE
NEW CONFERENCE
ENTRY
ODOT
BREAK
ROOM
ODOT OFFICE
129 NEW ODOT
OFFICE
RECEPTION
OFFICE
111A
OFFICE
111B
ODOT BRIDGE
CREW
DMV
OFFICE
113B
DMV
OFFICE
113C
DATA ROOM
NEW OFFICE
NEW OFFICE
NEW
UNISEX
RESTROOM
ENLARGED AREA #1,
SEE DRAWING A104
ENLARGED AREA #3,
SEE DRAWING A105
ENLARGED AREA #2,
SEE DRAWING A104
EXISTING
FLOOR
VENTS, TYP.
HALLWAY
120A
123A123B
111A
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4060901
ODOT COOS BAY
OFFICE BUILDING REMODEL
1155 S 5th ST, COOS BAY, OR 97420 13 06/09/26
FRANCO
FRANCO
MIKE SCHWEIZER
MIKE SCHWEIZER
FLOOR PLAN A103
OVERALL FLOOR PLAN
SCALE: 3/16" = 1'-0"
HALLWAY
UTILITY
ROOM
NEW OPEN
OFFICE
STORAGE /
SERVER
OFFICE
NEW CONFERENCE
RECEPTION
NEW OFFICE
115NEW OFFICE
3'-0"
10'-0"
ALIGN WITH
EXISTING
WALL
W2
W2
W2
W2
2'-0"
117A
120A
122A
W1
W1
SEE DETAIL
OFFICE
111A
OFFICE
111BW1
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4060901
ODOT COOS BAY
OFFICE BUILDING REMODEL
1155 S 5th ST, COOS BAY, OR 97420 13 06/09/26
FRANCO
FRANCO
MIKE SCHWEIZER
MIKE SCHWEIZER
ENLARGED AREAS #1 AND #2 A104
ENLARGED AREA #1
SCALE: 3/8" = 1'-0"
KEYED NOTES:
1. CONSTRUCT NEW WALLS AND DOOR, SEE DETAILS
2. REINSTALL SALVAGED LEFTOVER PANELS FROM DEMOUNTABLE MODULAR WALLS, REINSTALL AS SHOWN.
DISPOSED OF ANY ADDITIONAL LEFTOVER DEMOUNTABLE WALL PANELS IN ACCORDANCE WITH ALL LAWS
AND REGULATIONS.
3. INSTALL NEW WINDOW, SEE DETAIL
4. OTHERS TO REINSTALL ALL DATA RELATED WIRING AND DATA RACK IN NEW SERVER ROOM.
5. REINSTALL FLOOR VENTS AND REBALANCE AIR SUPPLY AS REQUIRED.
6. PATCH FLOORING TO MATCH EXISTING FINISH AS REQUIRED.
ENLARGED AREA #2
SCALE: 3/8" = 1'-0"
A107
A107
A107
NOTE:
SEE DRAWING A105 FOR WALL TYPES.
A107
ODOT
BREAK
ROOM
ODOT OFFICE
129 NEW ODOT
OFFICE
NEW
UNISEX
RESTROOM
9'-0"
W2
W2
W2
±5'-3"
±1'-4"
±5'-5"±2'-6"3'-0"±3'-1"
A105
18" MIN18" MIN
5'-2"
HALLWAY
129A 130A
131A
123A
8'-0"
EXISTING
FLOOR VENT
40" 2'-0"
MIRROR
(MR1)
36"6"
18"
ADA TOILET
3'-0"
2'-0"
MOTION SENSOR
LIGHT SWITCH AND
EXHAUST FAN
GFCI
RECEPTACLE
9" MIN.
MIN. 27" 34"
8" MIN.
17" MIN.
INSULATION
48"
2'-0"
COVE SHEET VINYL
FLOORING 6", TYP.
48"
SEAT COVER
DISPENSER (SG1)
SOAP DISPENSER
(SD1)
UNDER
LAV.
GUARD
MOLD RESISTANT
CEILING BOARD
PAPER TOWEL
DISPENSER (PT1)
MOLD RESISTANT
GYPSUM BOARD
MOLD RESISTANT
GYPSUM BOARD
MOLD RESISTANT
GYPSUM BOARD
DE-MOUNTABLE
MODULAR WALL
PANELS
5/8" GWB EACH SIDE
SOUND ATTENUATION BATT
2x4 STUD AT 16"
ON CENTER
W1 W2
MOLD RESISTANT GYPSUM
WALL BOARD INSIDE FACE
OF UNISEX RESTROOM
36" 26"
36"
42" 12"
17"-19"
TOP OF BAR
40"
40"18"
GRAB BAR
GRAB BAR
TOILET PAPER
DISPENSER (TP1)
MOLD RESISTANT
GYPSUM BOARD
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4060901
ODOT COOS BAY
OFFICE BUILDING REMODEL
1155 S 5th ST, COOS BAY, OR 97420 13 06/09/26
FRANCO
FRANCO
MIKE SCHWEIZER
MIKE SCHWEIZER
ENLARGED AREA #3 AND INTERIOR ELEVATIONS A105
ENLARGED AREA #3
SCALE: 3/8" = 1'-0"
KEYED NOTES:
1. FRAME IN AS REQUIRED TO MATCH WALL WIDTH AND FINISH. LEAVE A 3'-0"x6'-8"
FINISHED OPENING AS SHOWN.
2. REINSTALL EXISTING DOOR.
3. FRAME NEW 2x4 WALLS AS SHOWN FOR NEW RESTROOM, SEE DETAIL
4. INSTALL NEW DOOR.
5. FRAME NEW 2x4 WALLS , SEE DETAILS
6. REPLACE ALL EXISTING GYPSUM BOARD WITH MOLD RESISTANT GYPSUM BOARD
INSIDE THE NEW RESTROOM AS REQUIRED.
INTERIOR ELEVATIONS
SCALE: 3/4" = 1'-0"
WALL TYPES
A107
A107
A108
A107
A107
GENERAL PLUMBING NOTES:
1. ALL WORK SHALL BE IN ACCORDANCE WITH THE OREGON PLUMBING
SPECIALTY CODE AND REQUIREMENTS OF THE LOCAL JURISDICTION.
2. CONTRACTOR SHALL FURNISH AND INSTALL THE COMPONENTS
SHOWN ON DRAWINGS AS WELL AS ALL COMPONENTS AND
MATERIALS REQUIRED TO PROVIDE A COMPLETE AND FUNCTIONAL
PLUMBING SYSTEM FOR THE REMODELED BUILDING.
3. ALL PLUMBING WORK SHALL BE PERFORMED BY A LICENSED
PLUMBER.
4. CONTRACTOR IS RESPONSIBLE FOR APPLYING FOR AND OBTAINING
ALL REQUIRED PLUMBING PERMITS.
5. COMBINE ALL VENT PIPES INTO A SINGLE VENT STACK. ENGAGE A
QUALIFIED ROOFER TO INSTALL A WATERTIGHT ROOF PENETRATION
THAT MAINTAINS THE INTEGRITY OF THE EXISTING MEMBRANE ROOF.
COORDINATE WITH OTHER TRADES ON LOCATION AND SEALING OF
PENETRATION.
6. COORDINATE WITH OTHER TRADES FOR CONNECTIONS, ELECTRICAL,
AND FIXTURE LOCATIONS.
7. PROVIDE CLEANOUTS AT ALL NEW FIXTURES IN ACCORDANCE WITH
CODE REQUIREMENTS.
8. ALL SUPPLY PIPING SHALL BE PEX-A WITH BRASS FITTINGS.
CONNECTORS SHALL BE PEX COMPRESSION RING TYPE, NOT PUSH
ON OR METAL CRIMP RING TYPES. USE CODE APPROVED
CONNECTORS FOR TRANSITIONS BETWEEN MATERIALS.
9. CONTRACTOR IS RESPONSIBLE FOR DETERMINING ALL CONNECTION
POINTS FOR SUPPLY AND DRAIN PIPING.
10. ROUTE NEW DRAIN PIPING WITHIN THE EXISTING CRAWL SPACE.
11. PROVIDE AS-CONSTRUCTED PLUMBING DRAWINGS AT COMPLETION
OF WORK.
4"Ø
T
T
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4060901
ODOT COOS BAY
OFFICE BUILDING REMODEL
1155 S 5th ST, COOS BAY, OR 97420 13 06/09/26
FRANCO
FRANCO
MIKE SCHWEIZER
MIKE SCHWEIZER
REFLECTED CEILING AND POWER PLAN A106
REFLECTED CEILING PLAN
SCALE: 3/16" = 1'-0"
POWER PLAN
SCALE: 3/16" = 1'-0"
KEYED NOTES:
1. REINSTALL EXISTING LIGHT FIXTURE.
2. REINSTALL EXISTING HVAC RETURN VENT. REBALANCE SYSTEM FOR PROPER AIR DISTRIBUTION
IN THE BUILDING AS REQUIRED.
3. NEW LIGHT SWITCH. CONFIGURE SWITCH TO OPERATE ALL LIGHTS IN THE ROOM.
4. NEW MOTION SENSOR LIGHT TO OPERATE LIGHT AND EXHAUST FAN.
5. EXISTING LIGHT SWITCH. CONFIGURE SWITCH TO OPERATE ALL LIGHTS IN THE ROOM.
6. INSTALL NEW RESTROOM EXHAUST FAN WITH LIGHT IN GYPSUM CEILING ABOVE TOILET.
7. RECONNECT ALL EXISTING ELECTRICAL FIXTURES IN DEMOUNTABLE MODULAR WALL.
8. NEW DATA DROP IN CEILING FOR WIRELESS ACCESS POINT, INSTALL CONDUIT AND FACE PLATE
AS NEEDED.
9. NEW DATA DROP, INSTALL 4"x4" JUNCTION BOX AND MUD RING WITH 1" DIA. CONDUIT INTO
SPACE ABOVE SUSPENDED CEILING. CUT EXISTING WALL FINISHES AS REQUIRED FOR
INSTALLATION. PATCH EXISTING WALLS TO MATCH EXISTING ADJACENT FINISHES WITHOUT
VISIBLE EVIDENCE OF PATCHING AND PAINT TO MATCH EXISTING. FACE PLATE AND DATA WIRING
ARE BY OTHERS. TYPICAL FOR ALL AS SHOWN.
10. NEW GWB CEILING, SEE DETAIL
11. INSTALL EXTERIOR SOFFIT VENT FOR RESTROOM THROUGH EXISTING SOFFIT. HOOD IS TO BE
EQUIPPED WITH BUG SCREEN AND SHALL BE SEALED WEATHER TIGHT. PROVIDE BACKDRAFT
DAMPER IN ADJACENT DUCTWORK, SEE DETAIL
12. REINSTALL EXISTING THERMOSTAT.
13. ELECTRIC STRIKE AND MULLION MOUNTED CARD READER (CR2).
14. ELECTRIC STRIKE AND WALL MOUNTED CARD READER (CR1).
15. INSTALL NEW GFI RECEPTACLE AS REQUIRED BY CODE.
A108
A107
GENERAL ELECTRICAL NOTES:
1. DRAWINGS ARE SCHEMATIC IN NATURE AND SHOW MINIMUM REQUIREMENTS THAT MUST BE
INCLUDED. SPECIFIC CIRCUIT AND LOAD DESIGN IS BY THE CONTRACTOR. DRAWING SHOWS
MINIMUM REQUIREMENTS THAT MUST BE INCLUDED IN CONTRACTOR'S DESIGN AND INSTALLATION.
2. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICIAN AND SHALL BE IN
ACCORDANCE WITH THE OREGON ELECTRICAL SPECIALTY CODE.
3. CONTRACTOR SHALL FURNISH AND INSTALL THE COMPONENTS SHOWN ON DRAWINGS AS WELL
AS ALL COMPONENTS AND MATERIALS REQUIRED TO PROVIDE A COMPLETE AND FUNCTIONAL
ELECTRICAL SYSTEM. ALL WORK SHALL BE COMPLETED IN A NEAT AND WORKMAN LIKE MANNER.
SLOPPY WORK WILL NOT BE ACCEPTED.
4. CONTRACTOR IS RESPONSIBLE FOR APPLYING FOR AND OBTAINING ALL REQUIRED ELECTRICAL
PERMITS.
5. ONLY COPPER CONDUCTORS SHALL BE USED, NO ALUMINUM IS ALLOWED. WIRE TYPE SHALL BE
THHN UNLESS OTHERWISE NOTED OR REQUIRED.
6. WIRE RUNS SHALL BE MC CABLE AT CONCEALED LOCATIONS. CONCEAL WIRING AT FRAMED WALLS
AND CEILING.
7. PROVIDE GFCI BREAKERS WHERE REQUIRED BY CODE AND AT ALL RECEPTACLE LOCATIONS
SHOWN.
8. INSTALLATION OF NEW LOW VOLTAGE WIRING FOR DATA CONNECTIONS, ELECTRIC STRIKES, AND
CARD READERS TO BE INSTALLED BY OTHERS. CONTRACTOR TO CONNECT DEVICES. INSTALL
CONDUITS FOR DATA AND POWER FOR CARD READERS AND ELECTRIC STRIKES. CUT EXISTING
WALL FINISHES AS REQUIRED FOR INSTALLATION. PATCH EXISTING WALLS TO MATCH EXISTING ADJACENT FINISHES WITHOUT VISIBLE EVIDENCE OF PATCHING AND PAINT TO MATCH EXISTING.
2x4 STUD AT 16" ON CENTER
WITH 5/8" GWB EACH SIDE.
MATCH TEXTURE OF
EXISTING WALLS
BASE EACH SIDE OF NEW
WALL, MATCH EXISTING
EXISTING
FLOOR
FASTEN 2x4 WALL PLATE TO FLOOR WITH 10d
NAILS AT 16" ON CENTER 2x4 STUD AT 16" ON CENTER
WITH 5/8" GWB EACH SIDE.
MATCH TEXTURE OF
EXISTING WALLS
EXISTING
EXTERIOR WALL
FASTEN NEW 2x4 WALL TO
EXISTING EXTERIOR WALL
WITH #9x3" SCREW AT 12"
ON CENTER
EXISTING SUSPENDED
CEILING GRID
2x4 STUD AT 16" ON
CENTER WITH 5/8"
GWB EACH SIDE
1 MIN.
1" DIA. EMT CONDUIT BRACE WITH
FLATTENED ENDS (OR EQUIVALANT) AT 4'-0"
ON CENTER TO EXISTING ROOF FRAMING
2'-10"
3'-0"
4'-0"
A107
2'-0"
±8"
REPLACE GWB. AS
NEEDED AND PAINT TO
MATCH EXISTING
NEW 4x6 HEADER
1x4 TRIM
NEW 2x4 SILL
CUSTOMER
SIDE
OFFICE
SIDE
VINYL WINDOW
EXISTING 2X12
EXISTING
METAL SOFFIT
BACK FLOW
DAMPER
4" METALLIC
FLEXIBLE DUCT
SEAL
OPENING
EXISTING 2x4
EXISTING 1/2"
PLYWOOD
EXISTING CEILING GRID
EXISTING TRUSS
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4060901
ODOT COOS BAY
OFFICE BUILDING REMODEL
1155 S 5th ST, COOS BAY, OR 97420 13 06/09/26
FRANCO
FRANCO
MIKE SCHWEIZER
MIKE SCHWEIZER
DETAILS A107
BOTTOM OF WALL DETAIL
SCALE: 1-1/2" = 1'-0"
3 TOP OF WALL DETAIL
SCALE: 1-1/2" = 1'-0"
INTERIOR WALL ELEVATION
SCALE: 1" = 1'-0"
A107
WINDOW COUNTER
SCALE: 3" = 1'-0"
NEW WALL CONNECTION
SCALE: 1-1/2" = 1'-0"
A107 A107 A107
A107
EXHAUST HOOD PENETRATION
SCALE: 1" = 1'-0"
A107
EXISTING ROOF
FRAMING
2x6 AT 16" ON
CENTER
5/8 MOLD RESISTANT
GYPSUM BOARD
EXISTING
CORRIDOR WALL
NEW 2x4 WALL
EXISTING FLOOR
FRAMING
8'-0"
EXISTING
CEILING
GRID
NEW UNISEX
EXISTING
CORRIDOR
WALL
8' -0
" A .F
.F
2x6 LEDGER
2x4 WALL AT 16" ON
CENTER WITH SOUND
ATTENUATION BATT
5/8 MOLD RESISTANT
GYPSUM BOARD
8' -0
" A .F
.F
2x6 AT 16"
ON CENTER
FASTEN 2x6 LEDGER TO EACH
STUD WITH (2) SIMPSON
SDWS16300QR50 SCREWS
SOUND
ATTENUATION BATT
2x6 AT 16"
ON CENTER
FASTEN 2x6 LEDGER TO EACH
STUD WITH (2) SIMPSON
SDWS16300QR50 SCREWS
FASTEN CEILING JOIST TO
LEDGER WITH JOIST HANGER,
FASTEN PER MANUFACTURER
2x6 LEDGER
5/8 MOLD RESISTANT
GYPSUM BOARD
FASTEN CEILING JOIST TO
LEDGER WITH JOIST HANGER,
FASTEN PER MANUFACTURER
TRUSS
BOTTOM
CHORD
12" 2x4 FLAT BLOCKING, FASTEN TO
EXISTING TRUSS BOTTOM CHORD
WITH (2) 16d NAILS. TYP.
4" GAP
TRUSS WEB, TYP.
5/8 GWB
2x4 STUD
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4060901
ODOT COOS BAY
OFFICE BUILDING REMODEL
1155 S 5th ST, COOS BAY, OR 97420 13 06/09/26
FRANCO
FRANCO
MIKE SCHWEIZER
MIKE SCHWEIZER
DETAILS A108
A108
A108
A108
A107
CELING TO NEW WALL CONNECTION
SCALE: 3" = 1'-0"
A108
CELING TO NEW WALL CONNECTION
SCALE: 3" = 1'-0"
A108
NEW WALL TO ROOF FRAMING CONNECTION
SCALE: 3" = 1'-0"
A108
SECTION
SCALE: 1" = 1'-0"
A108
F1
DOOR
WIDTH
6'-8"
F
DOOR
HEIGHT
DOOR WIDTH
DOOR TYPES
DOOR
WIDTH
6'-8"
WALL
HEIGHT
WOOD PANEL
F2
HOLLOW
METAL DOOR
FRAME
5/8" GWB
EACH SIDE
MATCH FRAMING
STUDS TO EXISTING,
16" ON CENTER
WOOD DOOR
5/8" MOLD RESISTANT
GYPSUM WALL BOARD INSIDE
FACE OF UNISEX RESTROOM
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4060901
ODOT COOS BAY
OFFICE BUILDING REMODEL
1155 S 5th ST, COOS BAY, OR 97420 13 06/09/26
FRANCO
FRANCO
MIKE SCHWEIZER
MIKE SCHWEIZER
DOOR AND HARDWARE SCHEDULE A109
DOOR AND HARDWARE SCHEDULE
HARDWARE
FIRE
PROTECTIO
N RATING
OTHER
REQUIREMENTS
NO.
SIZE DOOR FRAME DETAILS
WIDTH HEIGHT CONSTR. TYPE GLASS FNSH COL MATL TYPE FNSH COL HEAD JAMB SILL HINGE LOCK EXIT CLSR P-P STOP BOLT K-PL TSHLD W-S MISC
111A NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 - - - - - - - - ES1 - NOTE 6
117A 3'-0" 6'-8" WD F - NOTE 1 NOTE 4 HM F1 P4 4 1/A109 1/A109 - H1 L1 - - - S1 - - - - - -
120A NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 - - - - - - - - ES1 - NOTE 6
122A 3'-0" 6'-8" WD F - NOTE 1 NOTE 4 HM F1 P4 NOTE 2 1/A109 1/A109 1/A109 H1 L1 - - - S1 - - - - - -
123A NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 - - - - - - - - ES1 - NOTE 6
123B NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 - - - - - - - - ES1 - NOTE 6
129A NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 NOTE 3 - - - S1 - - - - -
130A 3'-0" 6'-8" WD F - NOTE 1 NOTE 4 HM F1 P4 NOTE 2 1/A109 1/A109 - H1 L1 - - - OHS1 - - - - - -
131A 3'-0" 6'-8" WD F - NOTE 1 NOTE 4 HM F2 P4 NOTE 2 1/A109 1/A109 - H1 L2 - - - OHS1 - - - - - -
ABBREVIATIONS:
AL ALUMINUM
AS AS SPECIFIED
CLSR CLOSER
COL COLOR
CONSTR CONSTRUCTION
FCTY FACTORY
FNSH FINISH
K-PL KICK PLATE
MATL MATERIAL
HTL METAL
HM HOLLOW METAL
OHC OVERHEAD COILING
OHCI OVERHEAD COILING INSULATED
SG SAFETY GLASS
TSHLD THRESHOLD
W-S WEATHERSTRIPPING
WD WOOD
NOTES :
1. SEE THIS SHEET FOR DOOR AND FRAME TYPES.
2. MATCH EXISTING DOOR AND FRAME FINISH AND COLOR.
3. EXISTING.
4. COLORS AS SELECTED BY CPM.
5. CONTRACTOR SHALL FIELD VERIFY CONDITIONS PRIOR TO ORDERING DOORS
6. ELECTRIC STRIKE INSTALLED IN EXISTING DOOR FRAME.
DOOR DETAIL
SCALE: 3" = 1'-0"
A109
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4060901
ODOT COOS BAY
OFFICE BUILDING REMODEL
1155 S 5th ST, COOS BAY, OR 97420 13 06/09/26
FRANCO
FRANCO
MIKE SCHWEIZER
MIKE SCHWEIZER
INTERIOR FINISH SCHEDULE A110
INTERIOR FINISH SCHEDULE
SPACE FLOOR BASE AND WAINSCOT TYPICAL WALL OTHER WALL CEILING MISCELLANEOUS
OTHER REQUIREMENTS
NO. NAME SUB FL FINISH COL HGT MATL FINISH COL WALLS MATL FINISH COL MATL FINISH COL HGT MATL FINISH COL ITEM MATL FINISH COL
111A EXISTING OFFICE NOTE 3 NOTE 3 NOTE 3 NOTE 6 VINYL FCTY NOTE 6 NEW GWB P2 NOTE 7 - - - - NOTE 3 NOTE 3 NOTE 3
111B EXISTING OFFICE NOTE 3 NOTE 3 NOTE 3 NOTE 6 VINYL FCTY NOTE 6 NEW GWB P2 NOTE 7 - - - - NOTE 3 NOTE 3 NOTE 3
115 NEW OFFICE NOTE 3 NOTE 3 NOTE 3 NOTE 6 VINYL FCTY NOTE 6 NEW GWB P2 NOTE 7 - - - - NOTE 3 NOTE 3 NOTE 3
116 EXISTING OFFICE NOTE 3 NOTE 3 NOTE 3 NOTE 6 VINYL FCTY NOTE 6 NEW GWB P2 NOTE 7 - - - - NOTE 3 NOTE 3 NOTE 3
117 NEW OFFICE NOTE 3 NOTE 3 NOTE 3 NOTE 6 VINYL FCTY NOTE 6 NEW GWB P2 NOTE 7 - - - - NOTE 3 NOTE 3 NOTE 3
118 NEW OPEN OFFICE NOTE 3 NOTE 9 NOTE 3 NOTE 6 VINYL FCTY NOTE 6 NEW GWB P2 NOTE 7 - - - - NOTE 3 NOTE 3 NOTE 3
122 NEW CONFERENCE NOTE 3 NOTE 3 NOTE 3 NOTE 6 VINYL FCTY NOTE 6 NEW GWB P2 NOTE 7 - - - - NOTE 3 NOTE 3 NOTE 3
128 NEW HALL NOTE 3 NOTE 3 NOTE 3 NOTE 6 VINYL FCTY NOTE 6 NEW GWB P2 NOTE 7 - - - - NOTE 3 NOTE 3 NOTE 3
129 EXISTING OFFICE NOTE 3 NOTE 3 NOTE 3 NOTE 6 VINYL FCTY NOTE 6 NEW GWB P2 NOTE 7 - - - - NOTE 3 NOTE 3 NOTE 3
130 NEW OFFICE NOTE 3 NOTE 3 NOTE 3 NOTE 6 VINYL FCTY NOTE 6 NEW GWB P2 NOTE 7 - - - - NOTE 3 NOTE 3 NOTE 3
131 NEW UNISEX RESTROOM NOTE 3 VIN NOTE 8 6" VINYL FCTY NOTE 8 ALL NOTE 5 P5 ALL - - - - NOTE 5 P5 NOTE 8
ABBREVIATIONS:
AS AS SPECIFIED
CLR CLEAR
COL COLOR
CONC CONCRETE
WD WOOD
EXP EXPOSED STRUCTURE
FCTY FACTORY
FNSH FINISH
GWB GYPSUM WALL BOARD
HGT HEIGHT
HDNR CLEAR FLOOR HARDENER
MATL MATERIAL
MET METAL
OTS OPEN TO STRUCTURE
SLR CLEAR SEALER
SST STAINLESS STEEL
CARP CARPET
TILE TILE
VIN SHEET VINYL
SAT SUSPENDED ACOUSTICAL CEILING
VINP VINYL PLANK
NOTES:
1. NUMBERS IN THE FNSH COLUMN REFER TO PAINT SYSTEMS IN SPECIFICATION SECTIONS
09 91 24 , 09 96 00.
2. CODES IN "COL" COLUMN REFER TO COLOR LIST ON THIS SHEET.
3. EXISTING MATERIALS IN PLACE .
4. FOR DOOR AND FRAME FINISHES, SEE DOOR AND HARDWARE SCHEDULE ON A113.
5. MOLD RESISTANT GYPSUM BOARD
6. MATCH EXISTING.
7. PAINT ONLY NEW WALLS OR OTHER NEW COMPONENTS TO MATCH EXISTING COLOR,AS
REQUIRED.
8. AS SELECTED FROM MANUFACTURERS STANDARD COLORS OR BY CONSTRUCTION
PROJECT MANAGER.
9. PATCH EXISTING FLOOR TO MATCH AS REQUIRED.
4x4
PRINTER
6x6
6x6
6x6 6x6
6x6
4x6
6x6
PRINTER
DMV
OFFICE
113A
DMV
STORAGE
113D
STORAGE
ROOM
113E
RECEPTION
113AENTRY
HALLWAY
DMV BREAK
ROOM
HALLWAY
ODOT
BRIDGE
COORDINATOR
111C
BLDG.
ENTRY
DMV CUSTOMER
SERVICE AREA
ENTRY
OFFICE
111A
OFFICE
111B
ODOT BRIDGE
CREW
DMV
OFFICE
113B
DMV
OFFICE
113C
DATA RACK
6x6
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4060901
ODOT COOS BAY
OFFICE BUILDING REMODEL
1155 S 5th ST, COOS BAY, OR 97420 13 06/09/26
FRANCO
FRANCO
MIKE SCHWEIZER
MIKE SCHWEIZER
FURNITURE PLAN A111
FURNITURE PLAN #1
SCALE: 3/16" = 1'-0"
NOTE: ALL FURNITURE WORK
TO BE DONE BY OTHERS.
| F4060901 - 03_COOS BAY OFFICE BUILDING REMODEL_PLAN T101.pdf |
| F4060901 - 03_COOS BAY OFFICE BUILDING REMODEL_PLAN C101.pdf |
| F4060901 - 03_COOS BAY OFFICE BUILDING REMODEL_PLAN A101.pdf |
| F4060901 - 03_COOS BAY OFFICE BUILDING REMODEL_PLAN A102.pdf |
| F4060901 - 03_COOS BAY OFFICE BUILDING REMODEL_PLAN A103.pdf |
| F4060901 - 03_COOS BAY OFFICE BUILDING REMODEL_PLAN A104.pdf |
| F4060901 - 03_COOS BAY OFFICE BUILDING REMODEL_PLAN A105.pdf |
| F4060901 - 03_COOS BAY OFFICE BUILDING REMODEL_PLAN A106.pdf |
| F4060901 - 03_COOS BAY OFFICE BUILDING REMODEL_PLAN A107.pdf |
| F4060901 - 03_COOS BAY OFFICE BUILDING REMODEL_PLAN A108.pdf |
| F4060901 - 03_COOS BAY OFFICE BUILDING REMODEL_PLAN A109.pdf |
| F4060901 - 03_COOS BAY OFFICE BUILDING REMODEL_PLAN A110.pdf |
| F4060901 - 03_COOS BAY OFFICE BUILDING REMODEL_PLAN A111.pdf |
File details come from the government source that posted it. Updated .