ESBD_468372_11192025v947_Attachment 7- Project Drawings.pdf
PDF 12 MB Posted
- Attached to
- Mopac Print Shop Upgrades Services
- Solicitation number
- 3202600107
- Issued by
- Texas
About this file
This is a comprehensive set of project drawings and architectural/engineering specifications for renovation and upgrade services at the Texas Workforce Commission's MOPAC Print Shop facility located at 12312 N. MOPAC Expressway, Austin, TX 78758. The project encompasses approximately 8,903 occupied square feet and includes demolition, interior renovation, mechanical/electrical/plumbing (MEP) system upgrades, structural modifications, roofing work, and interior finishes. Key scope elements include removal of existing partitions and finishes in designated areas, installation of a new Energy Recovery Ventilation (ERV) rooftop unit (RTU-5), new HVAC ductwork and controls, replacement of lighting fixtures (Alternate 01), new flooring materials (luxury vinyl tile), acoustic ceiling tile replacement, and ADA-compliant modifications. The project design adheres to the 2021 International Building Code, 2021 ICC codes, 2020 NFPA National Electric Code, and 2012 Texas Accessibility Standards, with occupancy classified as Type II-B Business use with 90 occupant load and 200-foot exit distances.
The drawings indicate a 100% submission issued November 18, 2025, with architectural documentation prepared by CLK Architects & Associates (615 N. Upper Broadway, Suite 1250, Corpus Christi, TX), structural engineering by Garza + McLain Structural Engineers Inc. (License #F-9331), and MEP design by Innovation Engineering Consultants PLLC (TX Registration #F-13764). The project includes detailed specifications for roof system replacement with fire-rated modified bitumen cap sheet and cool-roof surfacing, structural reinforcement of existing steel joists to support new equipment loads, new electrical paneling and distribution, and comprehensive interior partition details including fire-rated, smoke-rated, and acoustically-rated wall assemblies. Construction activities require coordination with the Texas Workforce Commission regarding site access, noise restrictions, and phasing to maintain operational building occupancy. No specific contract pricing, award dates, or response deadlines are provided in the technical drawings package.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
architects & associates clk 615 N. Upper Broadway
Suite 1250 Corpus Christi, TX 78401-0750
T: 361.884.3295 F: 361.884.3298 www.clkarch.com
Innovation Engineering Consultants, PLLC
TX Firm Registration # F-13764
10637 Leopard St.
Corpus Christi, TX 78410
Phone: (361) 504-4074
Email: dlara@iecmep.com
MOPAC PRINT SHOP
TEXAS WORKFORCE COMMISSION
12312 N. MOPAC EXPRESSWAY
AUSTIN, TX 78758
11/18/2025
100% SUBMISSION
11/18/2025
SHEET INDEX
NO. SHEET NAME LATEST REVISION LATEST REVISION DATE
0-PROJECT INFORMATION
0000 COVER
3-GENERAL
G001 GENERAL NOTES, ABBREVATIONS, AND SYMBOLS
G002 ADA - TAS 2012 REQUIREMENTS
G101 LIFE SAFETY PLANS
G102 INTERIOR PARTITION TYPE SCHEDULES
G103 ACOUSTICAL, SMOKE, & FIRE PARTIITON DETAILS
6-DEMOLITION
D110 DEMOLITION PLAN
D120 DEMOLITION RCP
7-ARCHITECTURAL
A100 SITE PLAN
A101 ROOF PLAN
A110 REFERENCE PLAN
A120 REFLECTED CEILING PLAN
A120.1 REFLECTED CEILING PLAN ALTERNATE 01
A200 FINISH FLOOR PLAN
A300 ROOF PLAN
A301 CONSTRUCTION DETAILS
A302 CONSTRUCTION DETAILS
8-STRUCTURAL
S200 ROOF PLAN
S401 DETAILS
9-MEP
MEP1 MEP ROOF PLAN
10-MECHANICAL
M011 HVAC DEMOLITION PLAN
M111 HVAC PLAN
M211 HVAC LEGEND & SCHEDULES
M311 HVAC DETAILS
11-ELECTRICAL
E011 ELECTRICAL DEMOLITION LIGHTING PLAN (ALTERNATE #1)
E012 ELECTRICAL DEMOLITION POWER PLAN
E111 ELECTRICAL LIGHTING PLAN (ALTERNATE #1)
E121 ELECTRICAL POWER & SPECIAL SYSTEMS PLAN
E211 ELECTRICAL LEGEND, SCHEDULES & GENERAL NOTES
E311 ELECTRICAL RISER DIAGRAMS
Grand total: 30
APPLICABLE CODES & REGULATIONS:
PROJECT CODE SUMMARY
2021 ICC INTERNATIONAL BUILDING CODE
2021 ICC EXISTING BUILDING CODE
2021 ICC ENERGY CONSERVATION CODE
2021 ICC FUEL GAS CODE
2021 ICC MECHANICAL CODE
2021 ICC PLUMBING CODE
2020 NFPA NATIONAL ELECTRIC CODE
2012 TEXAS ACCESSIBILITY STANDARDS
AMERICANS WITH DISABILITIES ACT, TITLE III
2021 ICC INTERNATIONAL FIRE CODE
LOCAL ORDINANCES:
PROJECT SQUARE FOOTAGE:
TOTAL BUILDING:
RENOVATION:
OCCUPANCY TYPE:
OCCUPANT LOAD:
CONSTRUCTION TYPE:
ALLOWABLE FLOOR AREA:
OCCUPANCY & AREA
FIRE RESISTANCE SCHEDULE:
PRIMARY STRUCTURAL FRAME:
EXTERIOR WALLS BEARING:
EXTERIOR WALLS NON-BEARING:
INTERIOR WALLS BEARING:
FIRE BARRIERS:
INTERIOR WALLS NON-BEARING:
FLOOR CONSTRUCTION:
ROOF CONSTRUCTION:
WF COLUMN:
TS COLUMN/TRUSS:
WF BEAM/GIRDER:
SECONDARY WF BEAMS/GIRDERS:
SECONDARY WF BEAMS/GIRDERS:
SECONDARY TS COLUMN/TRUSS:
SECONDARY TS COLUMN/TRUSS:
REFERENCEDETERMINATION
MIN. EGRESS WIDTH @ CORRIDOR:
DOOR WIDTH:
AREA OF REFUGE:
FIRE SPRINKLER SYSTEM:
LIFE SAFETY
STAIRWAY WIDTH:
EXIT DISTANCE:
8,903 OCCUPIED SF
8,903 SF
0 Hr
0 Hr
0 Hr
0 Hr
0 Hr
0 Hr
IBC Table 601
1 Hr IBC Table 508.4, Sections 713 & 1023
1/2 Hr IBC Section 708
0 Hr
0 Hr
0 Hr
0 Hr
0 Hr
0 Hr
0 Hr
0 Hr
TYPE: II-B
23,000
IBC Sections 310, 311
IBC Table 1004.1.1
IBC Ch. 6
IBC Table 503
MIN 36"
MIN 36"
IBC Table 1020.2
IBC Section 1010
IBC Section 1009.3.8
IBC 903.2.8, IFC 1103.5
MIN 44" IBC Section 1011
IBC Table 1017.2
B-BUSINESS
NONE
200 FT
PROJECT LOCATION
RFP # 3202600107
# POUND OR NUMBER
& AND
@ AT
ACT ACOUSTICAL CEILING TILE
ADMIN ADMINISTRATION OR ADMINISTRATOR
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AL, ALU ALUMINUM
ALUM ALUMINUM
ANOD ANODIZED
ASSIST ASSISTANT
BD BOARD
BLDG BUILDING
B.O. BOTTOM OF
BOT BOTTOM
CF CONTRACTOR FURNISHED
CFB CEMENT FIBER BOARD
CG CORNER GUARD
CI CONTRACTOR INSTALLED
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CLS CLOSET
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE MASONRY UNIT
CONF CONFERENCE
CONT CONTINUOUS
COL COLUMN
CORR CORRIDOR
CPT CARPET
CT CERAMIC TILE
CWT CERAMIC WALL TILE
DBL DOUBLE
DEMO DEMOLISH OR DEMOLITION
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DISC DISCONNECT
DN DOWN
DR DOOR
DWG DRAWING
DWGS DRAWINGS
JAN JANITOR
JNT JOINT
JT JOINT
LAM LAMINATE
LO LOW
LF LEFT
MANUF MANUFACTURER
MAX MAXIMUM
MCJ MASONRY CONTROL JOINT
MECH MECHANICAL
MEMBR MEMBRANE
MFG MANUFACTURER
MIN MINIMUM
MTD MOUNTED
MTG MOUNTING
MTL METAL
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
OC ON CENTER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFOI OWNER FURNISHED OWNER INSTALLED
OH OPPOSITE HAND
OPP HD OPPOSITE HAND
PCC PRE-CAST CONCRETE
PLAM PLASTIC LAMINATE
PLUMB PLUMBING
PLWD PLYWOOD
PNT PAINT
PSI POUNDS PER SQUARE INCH
PT PAINT OR PRESSURE TREATED
PVC POLYVINYL CHLORIDE
PWR POWER
RBR RUBBER
RCP REFLECTED CEILING PLAN
REF REFERENCE
REFR REFERENCE
RD ROOF DRAIN
REQ REQUIRE OR REQUIRED
RM ROOM
R.O. ROUGH OPENING
RT RIGHT
EA EACH
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
ELEV ELEVATION
EPDM ETHYLENE PROPYLENE DIENE M-CLASS (ROOFING)
EQ EQUAL
EQMT EQUIPMENT
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EXT EXTERIOR INSULATION AND FINISH SYSTEM
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED
EXP JT EXPANSION JOINT
EXT EXTERIOR INSULATION AND FINISH SYSTEM
EXT EXTERIOR
EXTG EXISTING
F/A, FA FIRE ALARM
FD FLOOR DRAIN
FEC FIRE EXTINGUISHER CABINET
F.F. FINISH FLOOR
FFE FINISHED FLOOR ELEVATION
FIN FINISHED FLOOR ELEVATION
FL FLOOR
FLR FLOOR
FLUOR FLUORESCENT
F.O. FACE OF
FT FEET, FOOT
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GFI GROUND FAULT INTERRUPTER
GND GROUND
GYP GYPSUM
GYP. BD. GYPSUM BOARD
H.C. HOLLOW CORE
HDW HARDWARE
HM HOLLOW METAL
HR HOUR
HRS HOURS
HVAC HEATING, VENTILATING, & AIR CONDITIONING
INSUL INSULATION
INT INTERIOR
IT INFORMATION TECHNOLOGY
SAT SUSPENDED ACOUSTICAL TILE
SCHED SCHEDULED
SDT STATIC DISSIPATIVE TILE
SF SQUARE FOOT
SHF SHEET FLOORING
SHT SHEET
SIM SIMILAR
SL SLOPE
SO STRUCTURAL OPENING
SPEC SPECIFICATION OR SPECIFIED
SPK SPRINKLER OR SPEAKER
SQ FT SQUARE FEET
SS SOLID SURFACE OR SANITARY SEWER
SSTL STAINLESS STEEL
STC SOUND TRANSMISSION COEFFICIENT
STL STEEL
STRUCT STRUCTURAL
SYS SYSTEM
T/D TELEPHONE / DATA
T&G TONGUE & GROOVE
TBD TO BE DETERMINED
TELE TELEPHONE
THK THICKNESS OR THICK
TLT TOILET
T.O. TOP OF
T.O.C. TOP OF CONCRETE
T.O.S. TOP OF STEEL
TPD TOILET PAPER DISPENSER
TR TRIM
TYP TYPICAL
VCT VINYL COMPOSITION TILE
VWC VINYL WALL COVERING
VERT VERTICAL
TELE TELEPHONE
TOB TOP OF BEAM
TOJ TOP OF JOIST
TOP TOP OF PARAPET
TOR TOP OF ROOF
TOS TOP OF STRUCTURE
TV TELEVISION
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
UON UNLESS OTHERWISE NOTED
W/ WITH
EQ-X
ROOF PITCH
KEY NOTE SYMBOLS -
SHEET BASED
SEE CORRESPONDING
NUMBERED KEY NOTE ON
SHEET WHERE
REFERENCE OCCURS
SPECIALTY EQUIPMENT TAG
WALL SECTION
WALL SECTION NUMBER
SHEET WHERE DRAWN
DIRECTION OF VIEW
DETAIL REFERENCE
A102 2
ELEVATION REFERENCE
SEE PARTITION SYMBOL
DESCRIPTION ON SHEET
G SERIES
SHEET WHERE DRAWN
ELEVATION NUMBER AND
DIRECTION OF VIEW
SHEET WHERE
DRAWN,
HYPHEN INDICATES
DETAIL
ON SAME SHEET.
DETAIL NUMBER
A101
SIM
A101
SIM
WINDOW TAG
DOOR NUMBER (SEE
SCHEDULE)
ROOM TAG
PARTITION TYPE TAG
REFERENCE SYMBOLS & TAGS
SECOND
LEVEL 0'-0"
FLOOR REFERENCE
REVISION NUMBER AND EXTENT
NAME OF LEVEL
INDICATES HEIGHT
REVISION NUMBER -
SEE REVISION ON
TITLE BLOCK OF
EACH SHEET
EXTENT OF
CURRENT REVISION
MATCH LINE REFERENCE
DRAWING SIDE
DRAWING WHERE
CONTINUATION IS
FOUNDA101
ROOM
NAME
?XX
12" 6"
1. REFER TO COMPLETE SET OF ISSUED CONTRACT DOCUMENTS FOR APPLICABLE NOTES,
ABBREVIATIONS, AND SYMBOLS.
2. DO NOT SCALE THE DRAWING. IF DIMENSIONS ARE IN QUESTION. OBTAIN CLARIFICATION FROM THE
ARCHITECT BEFORE CONTINUING.
3. DIMENSIONS SHOWN ON THE FLOOR PLANS FOR NEW CONSTRUCTION ARE TO THE FACE OF FINISH
OF INTERIOR WALLS, TO CENTER LINE OF COLUMNS AND TO FACE OF CONCRETE OR MASONRY
WALLS, UNLESS OTHERWISE INDICATED. DIMENSIONS IN RENOVATED AREAS ARE FROM FINISH FACE OF EXISTING WALLS AND TO FINISH FACE OF NEW STUD WALLS, UNLESS OTHERWISE INDICATED.
4. FIELD MEASURE AND CONFIRM DIMENSIONS FOR OWNER PROVIDED EQUIPMENT AND FURNISHINGS.
COORDINATE WITH THE OWNER ON DELIVERY AND INSTALLATION OF OF/CI EQUIPMENT. MINIMUM
REQUIRED OPENINGS AND ACCESSIBLE ROUTES TO THE INSTALLATION AREA SHALL BE
COORDINATED WITH THE SUPPLIER.
5. FINISH FLOOR ELEVATIONS ARE TO TOP OF CONCRETE SLAB UNLESS OTHERWISE NOTED.
6. COORDINATE EXACT SIZE AND PLACEMENT OF EQUIPMENT BASE AND HOUSEKEEPING PADS WITH
EQUIPMENT TO BE PROVIDED.
7. WHERE NEW GYPSUM BOARD PARTITIONS ARE A CONTINUATION OF AN EXISTING PARTITION OR COLUMN ENCASEMENT, THE FACE OF THE NEW GYPSUM BOARD SHALL BE ALIGNED WITH THE FACE OF THE EXISTING SURFACE. WHERE A ONE HOUR PARTITION IS SHOWN AS A CONTINUATION OF A
TWO-HOUR PARTITION OR COLUMN ENCASEMENT, THE FACE OF THE GYPSUM BOARD SHALL BE
OFFSET AS REQUIRED TO PROVIDE FACE ALIGNMENT OF GYPSUM BOARD ON BOTH SIDES.
8. LEVEL FLOORS SO THAT THEY DO NOT EXCEED A ¼" VARIANCE IN A 10'-0" RADIUS.
9. PIPING LOCATED ABOVE GRADE AND INSIDE THE BUILDING SHALL BE CONCEALED IN FURRED SPACES
WITH THE EXCEPTION OF PIPING IN STAIRWAYS, EQUIPMENT ROOMS AND POWERHOUSE.
COORDINATE WITH OTHER TRADES TO PROVIDE FURRING FOR PIPING INSTALLED IN FINISHED AREAS.
10. WHEN PROVIDED, ALL EXTERIOR STEEL HANDRAILS, GUARDRAILS, AND BOLLARDS SHALL BE
GALVANIZED AND PAINTED UNLESS OTHERWISE NOTED.
11. PARTITION TYPES AND FIRE RESISTIVE RATINGS INDICATED ON A WALL ARE TO BE CONTINUOUS FOR
THE LENGTH AND HEIGHT OF A PARTITION.
12. APPROVE FLOOR OUTLET LOCATIONS WITH ARCHITECT AND BUILDING MANAGEMENT PRIOR TO CORE
DRILLING.
13. OPENINGS IN A RATED WALL, FLOOR, CEILING AND ROOF ASSEMBLIES SHALL BE SEALED WITH A FIRE
RESISTANT JOINT SYSTEMS OR PROTECTED WITH A FIRE RATED CHASE.
14. EXIT SIGNS AND SMOKE DETECTORS LOCATED IN CEILINGS SHALL BE POSITIONED AS REQUIRED BY
THE AUTHORITY HAVING JURISDICTION.
15. WHERE MATERIALS ARE APPLIED TO, OR ARE IN DIRECT CONTACT WITH WORK INSTALLED BY
ANOTHER SUBCONTRACTOR, COMMENCEMENT OF WORK IMPLIES ACCEPTANCE OF THE SUBSTRATE
AS SUITABLE FOR THE APPLICATION INTENDED.
16. ISOLATE DISSIMILAR METALS TO PREVENT GALVANIC CORROSION.
17. SEALANTS EXPOSED TO VIEW SHALL BE CUSTOM COLOR AS SELECTED BY THE ARCHITECT.
18. COORDINATE LOCATION OF SEALANT AND COMPATIBILITY OF SEALANTS WITH ADJACENT WORK, INCLUDING MATERIALS AND OTHER CONTIGUOUS SEALANTS.
19. CAULK AT JUNCTURE OF INTERIOR FACES OF DOOR FRAMES, VIEW WINDOW FRAMES, EXTERIOR WINDOW FRAMES, AND CABINET WORK WITH ADJACENT MATERIALS. MAINTAIN THE FIRE RATING OF CONSTRUCTION AROUND CABINETS, PANELS, AND BOXES RECESSED IN FIRE RATED WALL, FLOOR, AND CEILING ASSEMBLIES RE: DETAIL X/A01-01.
20. ACCESSORIES SUCH AS GRAB BARS, TOWEL BARS, PAPER DISPENSERS AND SOAP DISHES INSTALLED
WITHIN 2' OF A URINAL, WATER CLOSET, SINK OR LAVATORY SHALL BE MOISTURE SEALED.
21. DO NOT HANG (SUPPORT) ANY ITEMS FROM METAL ROOF DECK. IT IS ACCEPTABLE TO ATTACH, I.E.
CEILING SYSTEM WIRE HANGERS FROM JOISTS AND/ OR BEAMS. IF NO JOIST OR BEAM, PROVIDE A
STEEL STRIP.
architects & associates clk
615 N. Upper Broadway
Suite 1250
Corpus Christi, TX
78401-0750
SHEET NUMBER
JOB NO.
DRN. BY:
ISSUE DATE:
CKD. BY:
T H
IS
I
S T
O G
IV
E
N O
T
IC
E A
N D
V E
R T
IF
Y
T H
A T
T H
E T
E X
A S
B O
A R
D O
F A
R C
H
IT
E C
T U
R A
L E
X A
M
IN
E R
S
T B
A E
H
A S
J U
R
IS
D
IC
T
IO
N O
V E
R T
H E
P R
O F
E S
S
IO
N A
L P
R A
C T
IC
E
O F
A R
C H
IT
E
C T
U R
E I
N T
H E
S T
A T
E O
F T
E X
A S
C
O N
T A
C T
T H
E T
B A
E A
T
-3
-9
, w w w
.t b a e.
st a te .t x.
u s O
R W
R
IT
E T
O T
H E
T E
X A
S B
O A
R D
O F
A R
C H
IT
E
C T
U R
A L
E X
A M
IN
E
R S
, P .O
. B O
X
, A U
S T
IN
, T
E X
A S
-2
REVISIONS
11/18/2025
T E X A S W
O R K F O
R C E C
O M
M
IS
S
IO
N M
O P A C P
R
IN
T S
H O
P
202551
AMR
AMR
G E
N E
R A
L N
O T E
S
A B
B R
E V
A T I O
N S
A
N D
S Y
M B
O L S
100% SUBMISSION
11/18/2025
G001
N
M
O P A C
E X P R
E S S W
A Y
A U
S T
IN
T X
LEGEND - ABBREVIATIONS
LEGEND - SYMBOLS
GENERAL NOTES - PROJECT
MARK DESCRIPTION DATE
architects & associates clk
615 N. Upper Broadway
Suite 1250
Corpus Christi, TX
78401-0750
SHEET NUMBER
T H
IS
I
S T
O G
IV
E
N O
T
IC
E A
N D
V E
R T
IF
Y
T H
A T
T H
E T
E X
A S
B O
A R
D O
F A
R C
H
IT
E C
T U
R A
L E
X A
M
IN
E R
S
T B
A E
H
A S
J U
R
IS
D
IC
T
IO
N O
V E
R T
H E
P R
O F
E S
S
IO
N A
L P
R A
C T
IC
E
O F
A R
C H
IT
E
C T
U R
E I
N T
A T
E O
F T
E X
A S
C
O N
T A
C T
T H
E T
B A
E A
T
-3
-9
, w w w
.t b a e.
st a te .t x.
u s O
R W
R
IT
E T
O T
H E
T E
X A
S B
O A
R D
O F
A R
C H
IT
E
C T
U R
A L
E X
A M
IN
E
R S
, P .O
. B O
X
, A U
S T
IN
, T
E X
A S
-2
FIG. 304.3.2
T-SHAPED TURNING SPACE
60 MIN
A R M
M
IN
M
IN
A R M
BASE
36 MIN
12 MIN
12 MIN
24 MIN
305 CLEAR FLOOR OR GROUND SPACE
304 TURNING SPACE
48 MIN
M
IN
FIG. 305.3
CLEAR FLOOR OR GROUND SPACE
FIG. 305.5
POSITION OF CLEAR FLOOR OR GROUND
SPACE
M
IN
30 MIN
M
IN
48 MIN
X
36 MIN
X
60 MIN
FIG. 305.7.1
MANEUVERING CLEARANCE IN
AN ALCOVE, FORWARD
APPROACH
FIG. 305.7.2
MANEUVERING CLEARANCE IN
AN ALCOVE, PARALELL
APPROACH
307 PROTRUDING OBJECTS
FIG. 307.2
LIMITS OF PROTRUDING OBJECTS
X
X
4 MAX
FIG. 307.3
POST-MOUNTED PROTRUDING OBJECTS
-8
-2
12 MAX
(a)
M
A X
5 X > 12
12 MAX
X > 12
M
IN
(b)
X
M
A X
FIG. 307.4
VERTICAL CLEARANCE
308 REACH RANGES
M
IN
M
A X
FIG. 308.2.1
UNOBSTRUCTED FORWARD REACH
M
A X
20 MAX
(a) (b)
>20-25 MAX
510-635
M
A X
FIG. 308.2.2
OBSTRUCTED HIGH FORWARD REACH
M
IN
M
A X
10 MAX
FIG. 308.3.1
UNOBSTRUCTED SIDE REACH
M
A X
M
A X
10 MAX
(a) (b)
>10-24
MAX255-610
M
A X
M
A X
FIG. 308.3.2
OBSTRUCTED HIGH SIDE REACH
403 WALKING SURFACES
FIG. 403.5.1
CLEAR WIDTH OF AN ACCESSIBLE
ROUTE
24 MAX
24 MAX
61048 MIN
M
IN
M
IN
M
IN
M
IN
FIG. 403.5.2
CLEAR WIDTH AT TURN
M
IN
42 MIN
42 MIN
X < 48
(a)
180 DEGREE TURN
(b)
180 DEGREE TURN
(EXCEPTION)
X < 48
36 MIN
36 MIN
M
IN
404 DOORS, DOORWAYS AND GATES
32 MIN
(a)
HINGED DOOR
32 MIN
32 MIN
(b)
SLIDING DOOR
(c)
FOLDING DOOR
18 MIN
M
IN
(a)
FRONT APPROACH, PULL
SIDE
M
IN
(b)
FRONT APPROACH, PUSH
SIDE
12 MIN
M
IN
36 MIN
M
IN
(c)
FRONT APPROACH, PUSH
SIDE DOOR PROVIDED WITH
BOTH CLOSER AND LATCH
(d)
HINGE APPROACH, PULL
SIDE
42 MIN
1065 5
M
IN
(e)
HINGE APPROACH, PULL SIDE
M
IN
22 MIN
(f)
HINGE APPROACH, PUSH
SIDE
M
IN
22 MIN
560 4
M
IN
24 MIN
(g)
HINGE APPROACH, PUSH
SIDE
DOOR PROVIDED WITH BOTH
CLOSER AND LATCH
(h)
LATCH APPROACH, PULL SIDE
M
IN
24 MIN
(i)
LATCH APPROACH, PULL SIDE
DOOR PROVIDED WITH
CLOSER
24 MIN
M
IN
(j)
LATCH APPROACH, PUSH
SIDE24 MIN
M
IN
(k)
LATCH APPROACH, PUSH
SIDE
DOOR PROVIDED WITH
CLOSER
FIG. 404.2.1
MANEUVERING CLEARANCES AT
MANUAL SWINGING DOORS AND
GATES
FIG. 404.2..4.2
MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS,
SLIDING DOORS, GATES AND FOLDING DOORS
M
IN
(a)
FRONT APPROACH
(b)
SIDE APPROACH
M
IN
22 MIN
M
IN
M
IN
5 24 MIN
(c)
POCKET OR HINGE APPROACH
(d)
STOP OR LATCH APPROACH
M
IN
18 MIN
X > 8
X > 8
(a)
PULL SIDE
M
IN
(b)
PUSH SIDE
12 MIN
X > 8
M
IN
(c)
PUSH SIDE DOOR PROVIDED WITH
BOTH CLOSER AND LATCH
FIG. 404.2.4.3
MANEUVERING CLEARANCES AT
RECESSED DOORS AND GATES
48 MIN
48 MIN
48 MIN
(a)
(b)
(c)
FIG. 404.2.6
DOORS IN SERIES AND GATES IN
SERIES
405 RAMPS
60 MIN
60 MIN
LANDIN
G
RAMP RUN LANDIN
G
AT LEAST AS WIDE AS RAMP RUN
60 MIN
LANDIN
G 6
M
IN
RAMP RUN
R A M
P R
U N
(a)
STRAIGHT
(b)
CHANGE IN DIRECTION
FIG. 405.7
RAMP LANDINGS
FIG. 405.9.1
EXTENDED FLOOR OR GROUND
SURFACE EDGE PROTECTION
FIG. 405.9.2
CURB OR BARRIER EDGE
PROTECTION
12 MIN
12 MIN
X < 4
406 CURB RAMPS
ADJOINING SURFACE
MAXIMUM SLOPE
CURB RAMP SLOPE120
FLARED SIDES
1:10 MAX SLOPE
SLOPE SLOPE
FIG. 406.2
COUNTER SLOPE OF SURFACES ADJACENT
TO CURB RAMPS
FIG. 406.3
SIDES OF CURB RAMPS
36 MIN
AT LEAST AS
WIDE AS CURB
RAMP
FIG. 406.4
LANDINGS AT THE TOP OF CURB RAMPS
48 MIN
24 MIN
24 MIN
FIG. 406.6
DIAGONAL OR CORNER TYPE CURB RAMPS
(a)
CUT THROUGH AT ISLAND
36 MIN
48 MIN
(b)
CURB RAMP AT ISLAND 505 HANDRAILS
FIG. 505.4
HANDRAIL HEIGHT
FIG. 505.10.1
TOP AND BOTTOM HANDRAIL EXTENSION
AT RAMP
FIG. 505.5
HANDRAIL
CLEARANCE
FIG. 505.10.2
TOP HANDRAIL
EXTENSION AT STAIR
FIG. 505.10.3
BOTTOM HANDRAIL
EXTENSION AT STAIR
602 DRINKING FOUNTAINS
604 WATER CLOSETS AND TOILET COMP.
605 URINALS
609 GRAB BARS
(a)
STAIRS
1-1/2" MIN
-3
-9
-3
-9
-3
-9
(b)
RAMPS
(c)
WALKING
SURFACES
12 MIN
12 MIN
X
X
NOTE: X= TREAD
DEPTH
12 MIN
FIG. 602.5
DRINKING FOUNTAIN
SPOUT LOCATION
5 MAX
15 MIN
FIG. 604.3.1
SIZE OF CLEARANCE AT
WATER CLOSET
17-19 430-485
(b)
AMBULATORY
ACCESSIBLE WATER
CLOSETS
CL
60 MIN
M
IN
W
A L L H
A N
G
FIG. 604.3.2 (EXCEPTION)
OVERLAP OF WATER CLOSET
CLEARANCE IN RESIDENTIAL
DWELLING
18 MIN
CL
M
IN
60 MIN
FIG. 604.5.1
SIDE WALL GRAB BAR
AT WATER CLOSET
54 MIN
137012 MAX
42 MIN
FIG. 604.5.2
REAR WALL GRAB BAR AT
WATER CLOSETS
24 MIN
36 MIN
915 12 MIN
CL
TRANSFE
R SIDE 7-9
180-230
CL
M
IN
M
A X
FIG. 604.7
DISPENSER OUTLET
LOCATION
M
IN
F
L O
O R M
FIG. 604.8.1.2
WHEELCHAIR ACCESSIBLE
TOILET COMPARTMENT
DOORS
4 MAX
M
A X
M
IN
ALTERNATE
DOOR
LOCATION
FIG. 604.8.2
AMBULATORY ACCESSIBLE
TOILET COMPARTMENT
M
IN
35-37
890-940
M
IN
6 MIN
6 MIN
(C)
PLAN
6 MIN
6 MIN
9 MIN
12 MIN
PARTITIONPARTITION
(b)
ELEVATION
CHILDREN
(a)
ELEVATION
ADULT
FIG. 604.8.1.4
WHEELCHAIR ACCESSIBLE TOILET
COMPARTMENT TOE CLEARANCE
13-1/2 MIN
13-1/2 MIN
17 MAX
(A)
WALL HUNG
TYPE
(B)
STALL TYPE
FIG. 605.2
HEIGHT AND DEPTH OF URINALS
FIG. 609.2.2
GRAB BAR NON-CIRCULAR
CROSS SECTION
4-4.8 PERIMETER
100-120
(a) (b)
2M X
2MX
FIG. 609.3
SPACING OF GRAB BARS
(a)
PROJECTING
OBJECTS
1 1/2 MIN
12 MIN
SCALE 1/4" = 1'-0"
502 PARKING SPACES
96 MIN
(a)
CAR
132 MIN
(b)
VAN60 MIN
AREA TO BE
MARKED
F U
L L L
E N
G T H
O F P
A R K
IN
G S
P A C
E
FIG. 502.3
PARKING SPACE ACCESS AISLE
Figure 407.2.2.2 Visible Hall Signals
2½ min
2½ min m in
407 ELEVATORS
Figure 407.2.3.1 Floor Designations on
Jambs of Elevator Hoistway Entrances m in
Figure 407.2.3.2 Car Designations on Jambs of Destination-Oriented Elevator
Hoistway Entrances
C m in
Figure 407.4.1 Elevator Car and Door
Sizes
80 min
42 min m in m in
(a) centered door
Figure 407.4.1 Elevator Car and Door Sizes
68 min
36 min m in m in
(b) side (off-centered) door
Figure 407.4.1 (Exception) Existing Elevator Car
Configuration m in
36 min
16 sq ft min
1.5 m²
(e) Exception existing elevator car configuration
703 SIGNS
M
IN
JOB NO.
DRN. BY:
ISSUE DATE:
CKD. BY:
REVISIONS
TACTILE CHARACTERS SHALL BE
LOCATED 48" MIN. AFF, MEASURED
FROM BASELINE OF LOWEST
TACTILE CHARACTER AND 60" MAX.
AFF MEASURED FROM BASELINE OF
HIGHEST TACTILE CHARACTER
T E X A S W
O R K F O
R C E C
O M
M
IS
S
IO
N M
O P A C P
R
IN
T S
H O
P
A D
A
T A
S
R
E Q
U I R
E M
E N
T S
11/18/2025
G002
N
M
O P A C
E X P R
E S S W
A Y
A U
S T
IN
T X
11/18/2025
100% SUBMISSION
BUSINESS: 8,903 SQ. FT.
FEC
93'
128'
FE ON
BRACKET
architects & associates clk
615 N. Upper Broadway
Suite 1250
Corpus Christi, TX
78401-0750
SHEET NUMBER
JOB NO.
DRN. BY:
ISSUE DATE:
CKD. BY:
T H
IS
I
S T
O G
IV
E
N O
T
IC
E A
N D
V E
R T
IF
Y
T H
A T
T H
E T
E X
A S
B O
A R
D O
F A
R C
H
IT
E C
T U
R A
L E
X A
M
IN
E R
S
T B
A E
H
A S
J U
R
IS
D
IC
T
IO
N O
V E
R T
H E
P R
O F
E S
S
IO
N A
L P
R A
C T
IC
E
O F
A R
C H
IT
E
C T
U R
E I
N T
A T
E O
F T
E X
A S
C
O N
T A
C T
T H
E T
B A
E A
T
-3
-9
, w w w
.t b a e.
st a te .t x.
u s O
R W
R
IT
E T
O T
H E
T E
X A
S B
O A
R D
O F
A R
C H
IT
E
C T
U R
A L
E X
A M
IN
E
R S
, P .O
. B O
X
, A U
S T
IN
, T
E X
A S
-2
REVISIONS
11/18/2025
T E X A S W
O R K F O
R C E C
O M
M
IS
S
IO
N M
O P A C P
R
IN
T S
H O
P
202551
D. TORRES
A. RIOJAS
L I F E
S A
F E
T Y
P L A
N S
100% SUBMISSION
11/18/2025
G101
N
M
O P A C
E X P R
E S S W
A Y
A U
S T
IN
T X
SCALE:G101 1/4" = 1'-0"
1 LIFE SAFETY FLOOR PLAN
PARTITION TYPES
GENERAL NOTES
1. REFER TO FLOOR PLAN SERIES A-100 FOR LOCATION OF PARTITION TYPES. ALL
PARTITIONS ARE TYPE " A41 " UNLESS NOTED OTHERWISE. NOT ALL PARTITION TYPES
SHOWN ARE UTILIZED.
PARTITION TYPE TAG
(AS SHOWN ON PLANS IN A-100 SERIES)
SPECIAL DESIGNATIONS ARE ADDED AS LAST DIGIT(S) OF A WALL TAG TO DESIGNATE THE
FOLLOWING :
S = SMOKE RATED. SEE SMOKE PARTITION DETAILS. PROVIDE FIRESTOP TRACK AT
HEAD, PROVIDE SMOKE SEAL AND ACOUSTICAL SEALANT.
2. REFER TO A-600 SERIES FOR FINAL FINISHES ON PARTITIONS. PARTITION TYPES IN
CHARTS REFER TO BASE WALL ONLY.
3. PROVIDE 5/8" THK. CEMENT BOARD IN LIEU OF GYP. BOARD AS SUBSTRATE FOR
AREAS FINISHED WITH WALL TILE.
4. WHEN BLOCKING IS REQUIRED IN A PARTITION, USE A MINIMUM .033" (20 GA) STUD.
5. "LINE OF STRUCTURE" AS SHOWN AT THE HEAD CONDITIONS OF THE PARTITION
DETAIL DOES NOT INDICATE THE EXACT CONSTRUCTION CONDITION. REFER TO G
SERIES FOR ADDITIONAL INFORMATION CONCERNING RATED PARTITIONS.
6. ISOLATE NON-LOAD BEARING FRAMING FROM STRUCTURAL ELEMENTS TO PREVENT
THE TRANSFER OF LOAD TO PARTITION FRAMING. STOP STUDS 3/4" BELOW CEILING
RUNNER (TOP TRACK) TO ALLOW FOR VERTICAL EXPANSION. SET TOP TRACK 1"
BELOW DEFLECTION CHANNEL. DO NOT ATTACH STUDS TO TOP TRACK. DO NOT
ATTACH GYPSUM BOARD TO THE DEFLECTION TRACK. THIS MAY ALSO BE ACHIEVED,
AT THE CONTRACTOR'S OPTION, BY UTILIZING THE PROPRIETARY SYSTEM DESCRIBED
IN THE SPECIFICATIONS.
7. ALL GYP BOARD USED IN CONSTRUCTION TO BE TYPE X SHEET ROCK UNLESS STATED
OTHERWISE IN DETAIL DRAWINGS.
8. REFER TO G103 FOR ACOUSTICAL, SMOKE, AND FIRE PARTITION DETAILS.
9. FIRE RATED, SMOKE RATED, AND ACOUSTICAL WALLS TO HAVE FIRESTOP TRACK AT
THE HEAD ASSEMBLY. SEE PARTITION TYPES LEGEND ON PLAN SHEETS AND
PARTITION TYPE SCHEDULES FOR WALL TYPE INFORMATION. WALLS TO HAVE
SEALANTS USED AS FOLLOWS:
FIRE RATED=FIRE SEALANT TO MEET FIRE RATING
SMOKE PARTITION=SMOKE SEALANT TO MEET SMOKE SEAL AND ACOUSTICAL (IF
APPLICABLE) STC RATING
ACOUSTICAL=ACOUSTICAL SEALANT TO MEET ACOUSTICAL STC RATING (AND SMOKE IF
APPLICABLE)
SMOKE BARRIER=SMOKE/FIRE BARRIER SEALANT TO MEET FIRE AND SMOKE RATING
NON-RATED PARTITIONS TO HAVE SEALANT AS SPECIFIED.
FIRE RATED PARTITIONS
1. REFER TO G SERIES FOR ADDITIONAL INFORMATION ON PENETRATIONS THRU RATED
PARTITIONS, FIRE RESISTANT JOINT SYSTEMS, SLIP TRACKS AT NON-BEARING
PARTITIONS CONNECTION TO STRUCTURE AND WALL PRIORITY.
2. ALL BATTS AND BLANKETS IN RATED PARTITIONS MUST BEAR THE REQUIRED UL
CLASSIFICATION MARKING AS TO FIRE-RESISTANCE. REFER TO CODE COMPLIANCE
DETAILS IN THE PROJECT CODE SUMMARY.
3. STAGGER AND SEAL ALL JOINTS ON MULTIPLE GYPSUM BOARD LAYER PARTITIONS.
4 SEAL PARTITIONS AIR TIGHT AT FLOORS, SIDES, AND CEILINGS ON BOTH SIDES WITH
FIRE SEALANT AS SPECIFIED
4. SEAL ALL WALL INTERSECTIONS AND CONTROL JOINTS AT FIRE RATED PARTITIONS.
5. SEAL ALL CONDUIT, STRUCTURAL, DUCT AND LARGE PIPE PENETRATIONS
ACCORDING CODE COMPLIANCE DETAILS. REFERENCE PROJECT CODE
SUMMARY.
6. OUTLETS ON OPPOSITE SIDES OF FIRE RATED PARTITIONS SHOULD BE SEPARATED
BY A MINIMUM OF ONE STUD. SEAL OUTLETS IN AS REQUIRED FORE FIRE RATED
PARTITIONS. REFER TO PROJECT CODE SUMMARY.
7. ALL BOXES REQUIRED TO BE FIRE RATED SHALL BE SEALED PRIOR TO CLOSING IN
PARTITIONS AND INSTALLING DEVICES AND COVER PLATES.
SMOKE PARTITION THE FOLLOWING NOTES APPLY TO ALL PARTITIONS DESIGNATED TO
AS SMOKE (S) SPECIAL DESIGNATION.
1. ALL SMOKE CLASSED PARTITIONS SHALL BE CONSTRUCTED IN ACCORDANCE TO THE
REFERENCED TEST.
2. STAGGER AND SEAL ALL JOINTS ON MULTIPLE GYPSUM BOARD LAYER PARTITIONS.
3. SEAL PARTITIONS AIR TIGHT AT FLOORS, SIDES, AND CEILINGS ON BOTH SIDES WITH
SMOKE SEALANT AS SPECIFIED
4. SEAL ALL WALL INTERSECTIONS AND CONTROL JOINTS AT SMOKE CLASSED
PARTITIONS.
5. SEAL ALL CONDUIT, STRUCTURAL, DUCT AND LARGE PIPE PENETRATIONS
ACCORDING CODE COMPLIANCE DETAILS. REFERENCE PROJECT CODE
SUMMARY.
6. OUTLETS ON OPPOSITE SIDES OF ACOUSTICALLY CLASSED PARTITIONS SHOULD BE
SEPARATED BY A MINIMUM OF ONE STUD. SEAL OUTLETS IN AS REQUIRED. IF THE
PARTITION IS FIRE RATED THEN REFER TO PROJECT CODE SUMMARY.
7. ALL BOXES REQUIRED TO BE SMOKE SEALED SHALL BE SEALED PRIOR TO
CLOSING IN PARTITIONS AND INSTALLING DEVICES AND COVER PLATES.
ACOUSTICAL THE FOLLOWING NOTES APPLY TO ALL PARTITIONS DESIGNATED TO HAVE A
SOUND TRANSMISSION CLASS (STC) RATING ON THE PARTITION CHARTS.
1. ALL ACOUSTICALLY CLASSED PARTITIONS SHALL BE CONSTRUCTED IN
ACCORDANCE TO THE REFERENCED TEST.
2. STAGGER AND SEAL ALL JOINTS ON MULTIPLE GYPSUM BOARD LAYER PARTITIONS.
3. SEAL PARTITIONS AIR TIGHT AT FLOORS, SIDES, AND CEILINGS ON BOTH SIDES WITH
NON-HARDENING ACOUSTICAL SEALANT IN ACCORDANCE OF REFERENCED TEST.
4. AVOID COMPRESSING ACOUSTICAL BATT INSULATION AT BLOCKING AND RECESSED
ITEMS IN ACOUSTIC RATED WALLS
5. SEAL ALL WALL INTERSECTIONS AND CONTROL JOINTS AT ACOUSTICALLY
CLASSED PARTITIONS.
6. SEAL ALL CONDUIT, STRUCTURAL, DUCT AND LARGE PIPE PENETRATIONS
ACCORDING CODE COMPLIANCE DETAILS. REFERENCE PROJECT CODE
SUMMARY.
7. OUTLETS ON OPPOSITE SIDES OF ACOUSTICALLY CLASSED PARTITIONS SHOULD BE
SEPARATED BY A MINIMUM OF ONE STUD. SEAL OUTLETS IN AS REQUIRED. IF THE
PARTITION IS FIRE RATED THEN REFER TO PROJECT CODE SUMMARY.
8. ALL BOXES REQUIRED TO BE ACOUSTICALLY SEALED SHALL BE SEALED PRIOR TO
CLOSING IN PARTITIONS AND INSTALLING DEVICES AND COVER PLATES. VERIFY
COMPLIANCE WITH STC#.
?XX
A11
5/8" GYP BD, 1 LAYER EA SIDE
SAFB WHERE SCHEDULED
A
1-HR RATED WITH GYP BD
TO STRUCTURE ABOVE
NON-RATED WITH GYP BD
TO STRUCTURE ABOVE
NON-RATED WITH GYP BD
TO 6" ABOVE CEILING
NON-RATED WITH STUDS & GYP BD
TO FINISHED CEILING
PARTIAL HEIGHT PARTITION. SEE FLOOR
PLANS FOR HEIGHTS. NOTE 1.
STUD SIZE
BASIC PARTITION THICKNESS
ACOUSTICAL INSULATION THICKNESS
ACOUSTICAL TEST NUMBER
FIRE TEST NUMBER (WHERE APPLICABLE)
A1_ S T
C
A12
A13
A14
A21
A22
A23
A24
A20
2 1/2"
3 3/4"
USG
831001
2 1/2"
3 3/4"
2"
SA
831001
UL DES
U419
A2_ S T
C
A31
A32
A33
A34
A30
3 5/8"
4 7/8"
USG
860808
UL DES
U419
A3_ S T
C
A41
A42
A43
A44
A40
3 5/8"
4 7/8"
3 1/2"
USG
870717
UL DES
U419
A4_ S T
C
A51
A52
A53
A54
A50
4"
5 1/4"
USG 860808
NOTE 3
UL DES
U419
A5_ S T
C
A61
A62
A63
A64
A60
4"
5 1/4"
3"
SA 870717
NOTE 4
UL DES
U419
A6_ S T
C
A71
A72
A73
A74
A70
6"
7 1/4"
USG 860808
NOTE 3
UL DES
U419
A7_ S T
C
A81
A82
A83
A84
A80
6"
7 1/4"
6"
USG 870717
NOTE 4
UL DES
U419
A8_ S T
C
H E
A D
DETAIL NO
BASIC PARTITION THICKNESS
20 MIN. RATED WITH GYP BD
TO STRUCTURE ABOVE
A25 A35 A45 A55 A65 A75 A85
A91
A92
A93
A94
A90
8"
9 1/4"
7 1/2"
UL DES
U419
A9_ S T
C
A95
0.033 THK (20 GA) NON-STRUCTURAL
METAL FRAMING
NOTE:
1. REFER TO INTERIOR PARTITION DETAILS FOR PARTIAL HEIGHT PARTITION DETAIL. SEE STRUCTURAL DRAWINGS FOR MORE INFORMATION.
2. REFER TO TYPICAL WALL DETAILS FOR FLOOR DETAIL.
3. STC IS PREDICTED USING TEST REPORT PROVIDED BY CLARKDIETRICH AND RIVERBANK ACOUSTICAL LABORATORIES.
4. STC IS APPROXIMATED BY REFERENCE BASED ON 0.033" THICK (20 GA) STUDS @ 24" O.C., STC RATING NOT APPLICABLE WHERE DIFFERENT SPACING IS SPECIFIED.
5. PROVIDE 5/8" THK. CEMENT BOARD IN LIEU OF GYP. BOARD AS SUBSTRATE FOR AREAS FINISHED WITH WALL TILE.
35 36
36 46
44 10/G103
1/G102
SEE STRUCT.
DWGS
10/G10340
1/G102
10/G103
FLOOR
.033" (20 GA ) METAL STUD BRACING, NON-
STRUCTURAL SECURED TO STRUCTURE
ABOVE
CONTINUOUS HORIZONTAL METAL STUD,
NON-STRUCTURAL, REQUIRED
WHEN GYP BD DOES NOT EXTEND TO
STRUCTURE. SIZE AND NUMBER DEPENDS
ON PARTITION HEIGHT, SEAL AROUND
BRACE WHEN STC RATING IS REQUIRED
SEAL AROUND BRACE WHEN STC IS
REQUIRED AND WHEN GYP BOARD
CONTINUES TO STRUCTURE ABOVE
SCHEDULED CEILING
5/8" GYP BD EXTENDS TO 6" MIN
ABOVE FINISHED CEILING
METAL STUDS PER PARTITION
CHART
6" M
IN
A
LL
O W
E D
B Y
S T
U D
M A
N U
F
M A
X . U
N B
R A
C E
D H
E
IG
H T
1/ 4"
ACOUSTICAL SEALANT, BOTH SIDES
MINERAL FIBER PACKING
SOUND ATTENUATION BLANKET
(THICKNESS, STC PER PARTITION
TYPE)
ACOUSTICAL SEALANT, BOTH
SIDES (FIRE-RESISTANT RATED
SEALANT BOTH SIDES AT SIM)
NUMBER OF LAYERS OF
5/8" GYP BD PER
PARTITION TYPE
FLOOR
1/ 4"
METAL STUDS PER PARTITION CHART
NUMBER OF LAYERS OF
5/8" GYP BD PER PARTITION TYPE
(GYPSUM SHAFT LINER BOARD PER
PARTITION TYPE AT SIM)
1' -0
M
IN
O F
G Y
P P
A N
E L
LO
N
G S
ID
E
FIRE-RESISTIVE JOINT SYSTEM
REQD AT RATED AND/OR SMOKE
WALLS AND DECK.
HORIZ JOINTS ARE REQD TO
BE STAGGERED 12" OC MIN
AT UL# 411.
APPLY GYP BD WITH LONG DIMENSION
PARALLEL TO STUDS. ABUTTING
EDGES SHALL BE IN THE CENTER OF
THE STUDS.
DECK
CEILING
FLOOR
ELEVATION
2'
2'
12"
4'-0" GYP BD PANEL
4'-0" GYP BD PANEL
PLAN - UL # U411
HORIZ AND VERT JOINTS
OF OUTER LAYER OFFSET
12" FROM INNER LAYER
JOINTS.
MIN 2 1/2", 25 GA,
MTL STUDS
4'-0" GYP BD PANEL
UL # U465
2'
1'
24" MAX
STUD SPACING
2'
4'-0" GYP BD PANEL
MIN 3 5/8", 25 GA,
MTL STUDS
CENTER JOINTS ON STUD CENTERS STAGGER JOINTS ON
OPPOSITE SIDES OF THE
ASSEMBLY VERT ONLY
STUD CENTERLINES
7/8"
3"
FIRE SAFING
5/8" GYP BD
C OF JOINT
TO ATTACHMENT
L
2-HR FIRE RATED
SA 8602017
1-HR FIRE RATED
SA 923
ZINC CONTROL
JOINT (BOTH
SIDES)
JOINT WIDTH
1/2" MAX
JOINT WIDTH
1/2" MAX
7/8"
C OF JOINT
TO ATTACHMENT
L
ZINC CONTROL
JOINT (BOTH SIDES)
FIRE SAFING
COMPRESSED TO
FILL OPENING
5/8" GYP BD
CONTROL JOINTS AT 30'-0" MAX
2' - 0" MIN
VARIESVARIES
PROVIDE ONE JAMB
ANCHOR ABOVE EACH
HINGE AND BELOW TOP
HINGE. LOCATION OF
ANCHORS ON STRIKE
JAMB TO BE IDENTICAL.
PROVIDE ONE JAMB
ANCHOR ABOVE EACH
HINGE AND BELOW TOP
HINGE. LOCATION OF
ANCHORS ON STRIKE
JAMB TO BE IDENTICAL.
SECURE LT. GA. MTL
FRAMING DBL.
STUDS TO STRUT ABOVE
LT. GA. MTL. STUDS @ 16" O.C. (VERT.)
SECURE LT. GA. MTL
FRAMING DBL.
STUDS TO STRUT ABOVE
1-1/2" CRC REINF @
OPENINGS OVER 3'-4"
WIDE. EXTEND TO FIRST
STUD BEYOND BL STUDS
METAL RUNNER TRACK
BTWN STUDS. TURN
DOWN @JAMBS AND
SECURE ENDS
FL ANCHOR CLIPS
SECURED WITH 2
FASTENERS (MIN)
architects & associates clk
615 N. Upper Broadway
Suite 1250
Corpus Christi, TX
78401-0750
SHEET NUMBER
JOB NO.
DRN. BY:
ISSUE DATE:
CKD. BY:
T H
IS
I
S T
O G
IV
E
N O
T
IC
E A
N D
V E
R T
IF
Y
T H
A T
T H
E T
E X
A S
B O
A R
D O
F A
R C
H
IT
E C
T U
R A
L E
X A
M
IN
E R
S
T B
A E
H
A S
J U
R
IS
D
IC
T
IO
N O
V E
R T
H E
P R
O F
E S
S
IO
N A
L P
R A
C T
IC
E
O F
A R
C H
IT
E
C T
U R
E I
N T
A T
E O
F T
E X
A S
C
O N
T A
C T
T H
E T
B A
E A
T
-3
-9
, w w w
.t b a e.
st a te .t x.
u s O
R W
R
IT
E T
O T
H E
T E
X A
S B
O A
R D
O F
A R
C H
IT
E
C T
U R
A L
E X
A M
IN
E
R S
, P .O
. B O
X
, A U
S T
IN
, T
E X
A S
-2
REVISIONS
11/18/2025
T E X A S W
O R K F O
R C E C
O M
M
IS
S
IO
N M
O P A C P
R
IN
T S
H O
P
202551
D TORRES
A RIOJAS
I N
T E
R I O
R P
A R
T I T I O
N T
Y P
E S
C H
E D
U L E
S
100% SUBMISSION
11/18/2025
G102
N
M
O P A C
E X P R
E S S W
A Y
A U
S T
IN
T X
TYPICAL WALL DETAILS
SCALE:G102 1 1/2" = 1'-0"
1 PARTITION SECTION
SCALE:G102 1 1/2" = 1'-0"
2 TYP. PARTITION @ FLOOR
SCALE:G102 1 1/2" = 1'-0"
3 LOCATION OF GYP. BOARD CONTROL JOINTS
SCALE:G102 1 1/2" = 1'-0"
4 GYPSUM BOARD CONTROL JOINTS
SCALE:G102 1/4" = 1'-0"
5 DETAIL - DOOR FRAMING ELEVATION
PARTITION TYPES
GENERAL NOTES
1. REFER TO FLOOR PLAN SERIES A-100 FOR LOCATION OF PARTITION TYPES. ALL
PARTITIONS ARE TYPE " A41 " UNLESS NOTED OTHERWISE. NOT ALL PARTITION TYPES
SHOWN ARE UTILIZED.
PARTITION TYPE TAG
(AS SHOWN ON PLANS IN A-100 SERIES)
SPECIAL DESIGNATIONS ARE ADDED AS LAST DIGIT(S) OF A WALL TAG TO DESIGNATE THE
FOLLOWING :
S = SMOKE RATED. SEE SMOKE PARTITION DETAILS. PROVIDE FIRESTOP TRACK AT
HEAD, PROVIDE SMOKE SEAL AND ACOUSTICAL SEALANT.
2. REFER TO A-600 SERIES FOR FINAL FINISHES ON PARTITIONS. PARTITION TYPES IN
CHARTS REFER TO BASE WALL ONLY.
3. PROVIDE 5/8" THK. CEMENT BOARD IN LIEU OF GYP. BOARD AS SUBSTRATE FOR
AREAS FINISHED WITH WALL TILE.
4. WHEN BLOCKING IS REQUIRED IN A PARTITION, USE A MINIMUM .033" (20 GA) STUD.
5. "LINE OF STRUCTURE" AS SHOWN AT THE HEAD CONDITIONS OF THE PARTITION
DETAIL DOES NOT INDICATE THE EXACT CONSTRUCTION CONDITION. REFER TO G
SERIES FOR ADDITIONAL INFORMATION CONCERNING RATED PARTITIONS.
6. ISOLATE NON-LOAD BEARING FRAMING FROM STRUCTURAL ELEMENTS TO PREVENT
THE TRANSFER OF LOAD TO PARTITION FRAMING. STOP STUDS 3/4" BELOW CEILING
RUNNER (TOP TRACK) TO ALLOW FOR VERTICAL EXPANSION. SET TOP TRACK 1"
BELOW DEFLECTION CHANNEL. DO NOT ATTACH STUDS TO TOP TRACK. DO NOT
ATTACH GYPSUM BOARD TO THE DEFLECTION TRACK. THIS MAY ALSO BE ACHIEVED,
AT THE CONTRACTOR'S OPTION, BY UTILIZING THE PROPRIETARY SYSTEM DESCRIBED
IN THE SPECIFICATIONS.
7. ALL GYP BOARD USED IN CONSTRUCTION TO BE TYPE X SHEET ROCK UNLESS STATED
OTHERWISE IN DETAIL DRAWINGS.
8. REFER TO G103 FOR ACOUSTICAL, SMOKE, AND FIRE PARTITION DETAILS.
9. FIRE RATED, SMOKE RATED, AND ACOUSTICAL WALLS TO HAVE FIRESTOP TRACK AT
THE HEAD ASSEMBLY. SEE PARTITION TYPES LEGEND ON PLAN SHEETS AND
PARTITION TYPE SCHEDULES FOR WALL TYPE INFORMATION. WALLS TO HAVE
SEALANTS USED AS FOLLOWS:
FIRE RATED=FIRE SEALANT TO MEET FIRE RATING
SMOKE PARTITION=SMOKE SEALANT TO MEET SMOKE SEAL AND ACOUSTICAL (IF
APPLICABLE) STC RATING
ACOUSTICAL=ACOUSTICAL SEALANT TO MEET ACOUSTICAL STC RATING (AND SMOKE IF
APPLICABLE)
SMOKE BARRIER=SMOKE/FIRE BARRIER SEALANT TO MEET FIRE AND SMOKE RATING
NON-RATED PARTITIONS TO HAVE SEALANT AS SPECIFIED.
FIRE RATED PARTITIONS
1. REFER TO G SERIES FOR ADDITIONAL INFORMATION ON PENETRATIONS THRU RATED
PARTITIONS, FIRE RESISTANT JOINT SYSTEMS, SLIP TRACKS AT NON-BEARING
PARTITIONS CONNECTION TO STRUCTURE AND WALL PRIORITY.
2. ALL BATTS AND BLANKETS IN RATED PARTITIONS MUST BEAR THE REQUIRED UL
CLASSIFICATION MARKING AS TO FIRE-RESISTANCE. REFER TO CODE COMPLIANCE
DETAILS IN THE PROJECT CODE SUMMARY.
3. STAGGER AND SEAL ALL JOINTS ON MULTIPLE GYPSUM BOARD LAYER PARTITIONS.
4 SEAL PARTITIONS AIR TIGHT AT FLOORS, SIDES, AND CEILINGS ON BOTH SIDES WITH
FIRE SEALANT AS SPECIFIED
4. SEAL ALL WALL INTERSECTIONS AND CONTROL JOINTS AT FIRE RATED PARTITIONS.
5. SEAL ALL CONDUIT, STRUCTURAL, DUCT AND LARGE PIPE PENETRATIONS
ACCORDING CODE COMPLIANCE DETAILS. REFERENCE PROJECT CODE
SUMMARY.
6. OUTLETS ON OPPOSITE SIDES OF FIRE RATED PARTITIONS SHOULD BE SEPARATED
BY A MINIMUM OF ONE STUD. SEAL OUTLETS IN AS REQUIRED FORE FIRE RATED
PARTITIONS. REFER TO PROJECT CODE SUMMARY.
7. ALL BOXES REQUIRED TO BE FIRE RATED SHALL BE SEALED PRIOR TO CLOSING IN
PARTITIONS AND INSTALLING DEVICES AND COVER PLATES.
SMOKE PARTITION THE FOLLOWING NOTES APPLY TO ALL PARTITIONS DESIGNATED TO
AS SMOKE (S) SPECIAL DESIGNATION.
1. ALL SMOKE CLASSED PARTITIONS SHALL BE CONSTRUCTED IN ACCORDANCE TO THE
REFERENCED TEST.
2. STAGGER AND SEAL ALL JOINTS ON MULTIPLE GYPSUM BOARD LAYER PARTITIONS.
3. SEAL PARTITIONS AIR TIGHT AT FLOORS, SIDES, AND CEILINGS ON BOTH SIDES WITH
SMOKE SEALANT AS SPECIFIED
4. SEAL ALL WALL INTERSECTIONS AND CONTROL JOINTS AT SMOKE CLASSED
PARTITIONS.
5. SEAL ALL CONDUIT, STRUCTURAL, DUCT AND LARGE PIPE PENETRATIONS
ACCORDING CODE COMPLIANCE DETAILS. REFERENCE PROJECT CODE
SUMMARY.
6. OUTLETS ON OPPOSITE SIDES OF ACOUSTICALLY CLASSED PARTITIONS SHOULD BE
SEPARATED BY A MINIMUM OF ONE STUD. SEAL OUTLETS IN AS REQUIRED. IF THE
PARTITION IS FIRE RATED THEN REFER TO PROJECT CODE SUMMARY.
7. ALL BOXES REQUIRED TO BE SMOKE SEALED SHALL BE SEALED PRIOR TO
CLOSING IN PARTITIONS AND INSTALLING DEVICES AND COVER PLATES.
ACOUSTICAL THE FOLLOWING NOTES APPLY TO ALL PARTITIONS DESIGNATED TO HAVE A
SOUND TRANSMISSION CLASS (STC) RATING ON THE PARTITION CHARTS.
1. ALL ACOUSTICALLY CLASSED PARTITIONS SHALL BE CONSTRUCTED IN
ACCORDANCE TO THE REFERENCED TEST.
2. STAGGER AND SEAL ALL JOINTS ON MULTIPLE GYPSUM BOARD LAYER PARTITIONS.
3. SEAL PARTITIONS AIR TIGHT AT FLOORS, SIDES, AND CEILINGS ON BOTH SIDES WITH
NON-HARDENING ACOUSTICAL SEALANT IN ACCORDANCE OF REFERENCED TEST.
4. AVOID COMPRESSING ACOUSTICAL BATT INSULATION AT BLOCKING AND RECESSED
ITEMS IN ACOUSTIC RATED WALLS
5. SEAL ALL WALL INTERSECTIONS AND CONTROL JOINTS AT ACOUSTICALLY
CLASSED PARTITIONS.
6. SEAL ALL CONDUIT, STRUCTURAL, DUCT AND LARGE PIPE PENETRATIONS
ACCORDING CODE COMPLIANCE DETAILS. REFERENCE PROJECT CODE
SUMMARY.
7. OUTLETS ON OPPOSITE SIDES OF ACOUSTICALLY CLASSED PARTITIONS SHOULD BE
SEPARATED BY A MINIMUM OF ONE STUD. SEAL OUTLETS IN AS REQUIRED. IF THE
PARTITION IS FIRE RATED THEN REFER TO PROJECT CODE SUMMARY.
8. ALL BOXES REQUIRED TO BE ACOUSTICALLY SEALED SHALL BE SEALED PRIOR TO
CLOSING IN PARTITIONS AND INSTALLING DEVICES AND COVER PLATES. VERIFY
COMPLIANCE WITH STC#.
?XX
CEILING AS SCHEDULED
SEE RCP FOR CEILING HEIGHTS
3 5/8" 20 GAUGE METAL
STUDS @ 16" O.C.
5/8" TYPE X GYP.BD. EACH
SIDE FINISH AS SCHEDULED
WALL BASE
AS SCHEDULED
EXISTING CONCRETE FLOOR
CONSTRUCTION
SOUND BATT INSULATION
FOAM TOP TRACK SEAL AS SPECIFIED. SEAL TOP
OF WALL AGAINST DECK
TIGHTLY FILL ALL VOIDS TO LIMIT PASSAGE OF
SOUND
ACOUSTICAL SEALANT, BOTH SIDES, SMOKE
AND SOUND SEALANT AT SMOKE PARTITIONS
SEAL VOIDS FROM OUTSIDE AND
COVER BOX WITH 1/8" MIN
SOUND BATTS
CUT GYP BD TO ALLOW 1/4"
MIN OVERLAP BY FACE PLATE
SCHEDULED PARTITION
A MIN OF 1 STUD BETWEEN BOXES
FLEXIBLE CONDUIT
ACOUSTICAL OR FIRESTOP OUTLET BACKER PUTTY PAD
CAULK ALL VOIDS BETWEEN
GYP BD AND BOX
NOTES:
1. 12" MINIMUM UNLESS NOTED OTHERWISE IN PARTITION CHART.
2. REFER TO THIS SHEET FOR BACK TO BACK BOXES IN A RATED PARTITION.
N O
T E
DUCT.
GYPSUM BOARD
ACOUSTICAL
SEALANT
(AROUND
PERIMETER)
SHEET METAL
ENCLOSURE
SOUND ATTENUATION
BATTS
STEEL STUDS (PER
PARTITION TYPE),
PARTITION INTERSECTION
STEEL STUD (SIZED PER
PARTITION TYPE)
GYPSUM BOARD
ACOUSTICAL SEALANT
BATT INSULATION
JOINT
REINFORCEMENT
M A
X
16" MAX
M A
X
STEEL STUD
(SIZED PER
PARTITION TYPE)
CONTROL JOINT
FIBER GLASS PACKING
(3#-6# DENSITY)
PARTITION-WALL
INTERSECTION
ACOUSTICAL SEALANT
STEEL STUD (SIZED PER
PARTITION TYPE)
BATT INSULATION
GYPSUM BOARD
ACOUSTICAL SEALANT
BATT INSULATION
ACOUSTICAL SEALANT
PRIORITY 1 HIGHEST
PRIORITY 2
PRIORITY 3
PRIORITY 4
PRIORITY 5
PRIORITY 6 LOWEST
TWO HOUR RATED FIRE AND SMOKE
PARTITION
TWO HOUR RATED SHAFT WALL
TWO HOUR RATED PARTITION
ONE HOUR SMOKE PARTITION
ONE HOUR RATED PARTITION
PARTITION TO DECK
PARTITION TO 4" MIN ABOVE CEILING
WALL PRIORITY LEGEND
LOWER PRIORITY WALL
HIGHER PRIORITY WALLS
TO RUN CONTINUOUS PAST
LOWER PRIORITY WALL
THIS DRAWING IS FOR GRAPHIC
PRESENTATION ONLY. REF
PARTITION TYPE FOR NUMBER OF
LAYERS OF GYP BD, ETC.
CONT GYP BOARD ON
HIGHER PRIORITY WALL
HIGHER PRIORITY (FIRE-RATED) PARTITION
REF PARTITION CHARTS FOR RATING
TAPE AND BED PER UL DESIGN
NUMBER OF LOWER PRIORITY PARTITION
METAL TRIM
LOWER FIRE-RATING OR NO
FIRE-RATING REF PARTITION
CHARTS FOR RATING
MTL STUDS
NOTES: PER IBC 711.3.4
1. MAINTAINING FIRE RATING AROUND A GREATER THAN 16 SQ IN CABINET IS NOT NECESSARY IF THE
BOX HAS BEEN TESTED FOR USE IN A FIRE-RESISTANT RATED ASSEMBLY.
STL ELECTRICAL PANEL, FHC, FEC,
OTHER RECESSED CABINET OR BOX
OVER 16 SQ IN IN FACE SIZE. MAINTAIN
FIRE RESISTANT RATING OF THE
PARTITION ON ALL SIDES, TOP AND
BOTTOM OF THE CABINET.
ONE OR TWO LAYERS OF 5/8"
TYPE
GYP BD AS REQUIRED PER
PARTITION TYPE
2 1/2" MIN MTL
STUD 24" OC MAX
PROVIDE 6" OR 8"
STUDS FOR PIPING
AT FIRE HOSE
CABINET
VARIES
NOTES: PER IBC 711.3.4
1. FOR ALL ONE HOUR RATED PARTITIONS, TWO HOUR RATED PARTITIONS AND SMOKE PARTITIONS, SURFACE
AREA OF INDIVIDUAL METALLIC OUTLET OR SWITCH BOXES SHALL NOT EXCEED 16 SQUARE INCHES. THE AGGREGATED SURFACE OF ALL BOXES SHALL NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET OF WALL AREA. BOXES WHICH EXCEED THESE STANDARDS SHALL BE RECESSED AS SHOWN IN "RECESSED WALL CABINET DETAIL". BOXES < 16 SQ IN AND LOCATED ON OPPOSITE SIDES OF RATED FIRE SMOKE PARTITIONS
SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF 24 INCHES MINIMUM.
2. REFER TO 2/G103 FOR SOUND ATTENUATION DETAIL.
3. WHERE WALL CAVITY IS FILLED WITH MINERAL FIBER INSULATION, BOXES SHALL BE OF ANY MATERIAL AND
SEPARATED BY NOT LESS THAN THE DEPTH OF THE WALL CAVITY.
4. MEMBRANE PENETRATIONS FOR LISTED ELECTRICAL OUTLETS ARE PERMITTED PROVIDED THEY HAVE BEEN
TESTED FOR USE IN FIRE-RESISTANT RATED ASSEMBLIES.
5. UL DESIGN TESTED MOLDABLE PUTTY PADS MAY BE USED IN LIEU OF SEPARATING THE BOXES BY 24" AND
TO PROTECT > 16" SQ BOXES.
2'
2'-0" MIN
BETWEEN OUTLET BOXES ON OPPOSITE SIDES
OF WALL, OR SEE NOTE 3 BELOW
ACOUSTICAL SEALANT OR
FIRESTOP SEALANT ALL
AROUND BOX.
ONE OR TWO LAYERS
OF 5/8" GYP BD ON
EACH SIDE. REF
PARTITION TYPE
DESCRIPTION
STL TELEPHONE,
ELECTRICAL BOXES,
ETC.
MAX 16 SQUARE INCH
OPENING IN RATED OR
SMOKE WALL
DUCT.
GYPSUM BOARD
FIRE SEALANT
(AROUND
PERIMETER)
SHEET METAL
ENCLOSURE
SOUND ATTENUATION
BATTS
STEEL STUDS (PER
PARTITION TYPE),
5/8" GYP BD - TYPE X, 1 LAYER
ON
SYMBOL SIDE
C-H SHAFT WALL STUD OR BACK
TO BACK E-SHAPED SHAFT WALL
STUDS, .018" (25 GA)
SAFB WHERE SCHEDULED
1" GYPSUM SHAFT LINER BOARD
B A
S
IC
P A
R T
IT
IO
N T
H
IC
K N
E S
S
1" M
IN
1" M
IN
FLOOR OR ROOF ASSEMBLY
0'
STEEL STUD ATTACHED TO STRUCTURE
2" MIN TO CLOSURE
ATTACHMENT
FIRE-RESISTIVE
JOINT SYSTEM -
SEE
SPECIFICATIONS
FOR FLUTE PLUGS
SIZED TO MATCH
FLUTE SIZE
GYP BD ATTACHED
TO VERTICAL
STUDS
NOTES:
1. UL SYSTEM NO: HW-D-0884 AT FIRE RATED WALLS.
2. SIMILAR AT NON-RATED WALL EXCEPT USE ACOUSTICAL SEALANT AND BATTS IN LIEU
OF FIRE-RESISTIVE JOINT SYSTEM.
3. CONTRACTOR TO COMPLY WITH DETAIL SHOWN OR USE PROPRIETARY SYSTEM AS
DESCRIBED IN THE SPECIFICATIONS.
FLOOR/ROOF ASSEMBLY
FIRE RESISTIVE JOINT SYSTEM
AS SPECIFIED
GYP BD ATTACHED TO
VERTICAL STUDS
NOTES:
1. UL SYSTEM NO: HW-D-0884 AT FIRE RATED WALLS.
2. CONTRACTOR TO COMPLY WITH DETAIL SHOWN OR COMPLY WITH PROPRIETARY SYSTEM AS SPECIFIED.
3. SIMILAR AT NON-RATED WALL EXCEPT USE ACOUSTICAL SEALANT AND BATS IN LIEU OF FIRE-RESISTIVE JOINT SYSTEM.
SEALANT PER WALL TYPE
CEILING RUNNER
4" MIN OVERLAP
FIRESTOP TOP TRACK SEAL TO BE USED AT ALL FIRE/SMOKE
BARRIER PARTITIONS, AND ALL FIRE RATED WALLS.
ACOUSTICAL/SMOKE TOP TRACK SEAL TO BE USED AT ALL
ACOUSTICAL PARTITIONS AND SMOKE PARTITIONS.
PARALLEL TO METAL DECKING PERPENDICULAR TO METAL DECKING
TOP TRACK SEAL AS SPECIFIED. USE FIRE
STOP AT RATED WALLS. USE SMOKE AND
ACOUSTIC TRACK SEAL AT SMOKE OR
ACOUSTICAL WALLS.
TAPE AND SEAL CONCEALED
JOINTS IN RATED OR SMOKE WALL
PER UL DESIGN OF PARTITION
TYPE
VERIFY PIPE
SIZE
MIN
2"
M
IN2"
SCHEDULED PARTITION
RATED AND SMOKE WALLS SHALL
BE CONT BEHIND PIPE
2 1/2" MTL STUDS
EXTEND GYP BD TO 4" MIN ABOVE
CEILING LINE FOR FURR-OUT ONLY
PROVIDE FIRE RESISTANT JOINT SYSTEM
AT PENETRATION THROUGH FLOOR AND
DECK (ABOVE AND BELOW)
E Q
E
Q architects & associates clk
615 N. Upper Broadway
Suite 1250
Corpus Christi, TX
78401-0750
SHEET NUMBER
JOB NO.
DRN. BY:
ISSUE DATE:
CKD. BY:
T H
IS
I
S T
O G
IV
E
N O
T
IC
E A
N D
V E
R T
IF
Y
T H
A T
T H
E T
E X
A S
B O
A R
D O
F A
R C
H
IT
E C
T U
R A
L E
X A
M
IN
E R
S
T B
A E
H
A S
J U
R
IS
D
IC
T
IO
N O
V E
R T
H E
P R
O F
E S
S
IO
N A
L P
R A
C T
IC
E
O F
A R
C H
IT
E
C T
U R
E I
N T
A T
E O
F T
E X
A S
C
O N
T A
C T
T H
E T
B A
E A
T
-3
-9
, w w w
.t b a e.
st a te .t x.
u s O
R W
R
IT
E T
O T
H E
T E
X A
S B
O A
R D
O F
A R
C H
IT
E
C T
U R
A L
E X
A M
IN
E
R S
, P .O
. B O
X
, A U
S T
IN
, T
E X
A S
-2
REVISIONS
11/18/2025
T E X A S W
O R K F O
R C E C
O M
M
IS
S
IO
N M
O P A C P
R
IN
T S
H O
P
202551
D. TORRES
A. RIOJAS
A C
O U
S T I C
A L
S M
O K
E
F
I R
E P
A R
T I I T O
N D
E T A
I L S
100% SUBMISSION
11/18/2025
G103
N
M
O P A C
E X P R
E S S W
A Y
A U
S T
IN
T X
ACOUSTICAL/SMOKE
FIRE
CODE COMPLIANCE DETAILS
SCALE:G103 1 1/2" = 1'-0"
1 ACOUSTICAL WALL SECTION
SCALE:G103 1" = 1'-0"
2 ACOUSTICAL PLAN SECTION
SCALE:G103 1 1/2" = 1'-0"
3 ACOUSTICAL PARTITION SECTION
SCALE:G103 1 1/2" = 1'-0"
4 ACOUSTICAL PARTITION PLAN DETAILS
SCALE:G103 1 1/2" = 1'-0"
5 PARTITION PRIORITY LEGEND
SCALE:G103 1 1/2" = 1'-0"
6 PARTITION PLAN DETAIL
SCALE:G103 1 1/2" = 1'-0"
7 RECESSED WALL CABINET DETAIL
SCALE:G103 1 1/2" = 1'-0"
8 ADJ (non-listed) ELECTRICAL BOXES
SCALE:G103 1 1/2" = 1'-0"
9 2 HR FIRE DUCT PENETRATIONS
SCALE:G103 1 1/2" = 1'-0"
10 TOP TRACK SEAL
SCALE:G103 1 1/2" = 1'-0"
11 PIPE ENCLOSURE DETAIL
1. IT IS THE INTENT OF THE DEMOLITION TO REMOVE ALL EXISTING CONSTRUCTION
WHICH CONFLICTS WITH THE INTENT OF NEW CONSTRUCTION AND EVERY
DEMOLITION DETAIL MAY NOT NECESSARILY BE COVERED ON THESE DRAWINGS.
CONTRACTOR SHALL INCLUDE ALL DEMOLITION WORK EVEN IF NOT SPECIFICALLY
CALLED FOR.
2. WHERE REMOVAL OF EXISTING WALLS, PARTITIONS, EQUIPMENT, ETC DISTURBS
EXISTING MECHANICAL, PLUMBING, AND ELECTRICAL SERVICES, CONTRACTOR
SHALL MAKE PERMANENT REVISION AS REQUIRED AND IF NECESSARY PROVIDE
TEMPORARY SERVICES TO AREAS NOT SCHEDULED FOR DEMOLITION AND
REMODELING.
3. WHERE FIXTURES, DOORS AND OTHER ITEMS ARE REMOVED FROM WALL AND/OR
RELOCATED - PATCH AND REPAIR WALLS TO MATCH EXISTING FINISH. AT WALLS
THAT HAVE PAINTED GYP, PATCH, TEXTURE AND PAINT TO MATCH SURROUNDING
WALL. FOR WALLS PATCH AND REPAIR TO RECEIVE NEW FINISH AS SCHEDULED.
4. CONTRACTOR SHALL MAKE EVERY EFFORT TO KEEP ALL EXISTING FIREPROOFING
ON STRUCTURE UNDISTURBED. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY
TO REAPPLY FIREPROOFING THAT MAY BE REMOVED OR DAMAGED DURING
CONSTRUCTION.
5. CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF ALL FIRE RATED WALL
ASSEMBLIES SHOWN ON PLANS AND THOSE FOUND IN THE FIELD.
6. ALL EQUIPMENT THAT WILL NEED TO BE SALVAGED WILL BE REMOVED BY OWNER
PRIOR TO DEMOLITION.
DEMOLITION PLAN
GENERAL NOTES
DEMOLITION PLAN
LEGEND
DEMOLITION PLAN
KEY NOTES
REMOVE EXISTING MILLWORK/PLUMBING/EQUIPMENT -
SEE NOTES FOR RELOCATION OR DEMOLITION NOTES
REMOVE EXISTING PARTITION
REMOVE EXISTING DOOR
3 3
51 5
EXST'G OPEN WORK AREA
EXST'G OFFICE
EXST'G OFFICE
EXST'G OFFICE
EXST'G OFFICE
EXST'G OFFICE
EXST'G OFFICE
EXST'G OFFICE
EXST'G OFFICE
EXST'G OFFICE EXST'G OFFICE EXST'G OFFICE
EXST'G DATA
EXST'G
MECH/ELEC
EXST'G JANITOR
EXST'G STORAGE
EXST'G BREAK
ROOM
EXST'G WOMENSEXST'G MENS
EXST'G TRAINING
EXST'G TOILET
EXST'G TOILET
EXST'G
VESTIBULE
2 2
AREA OF
LIMITED SCOPE
AREA OF
LIMITED SCOPE
AREA OF
LIMITED SCOPE
architects & associates clk
615 N. Upper Broadway
Suite 1250
Corpus Christi, TX
78401-0750
SHEET NUMBER
JOB NO.
DRN. BY:
ISSUE DATE:
CKD. BY:
T H
IS
I
S T
O G
IV
E
N O
T
IC
E A
N D
V E
R T
IF
Y
T H
A T
T H
E T
E X
A S
B O
A R
D O
F A
R C
H
IT
E C
T U
R A
L E
X A
M
IN
E R
S
T B
A E
H
A S
J U
R
IS
D
IC
T
IO
N O
V E
R T
H E
P R
O F
E S
S
IO
N A
L P
R A
C T
IC
E
O F
A R
C H
IT
E
C T
U R
E I
N T
A T
E O
F T
E X
A S
C
O N
T A
C T
T H
E T
B A
E A
T
-3
-9
, w w w
.t b a e.
st a te .t x.
u s O
R W
R
IT
E T
O T
H E
T E
X A
S B
O A
R D
O F
A R
C H
IT
E
C T
U R
A L
E X
A M
IN
E
R S
, P .O
. B O
X
, A U
S T
IN
, T
E X
A S
-2
REVISIONS
11/18/2025
T E X A S W
O R K F O
R C E C
O M
M
IS
S
IO
N M
O P A C P
R
IN
T S
H O
P
202551
DT
A RIOJAS
D E
M O
L I T I O
N P
L A
N
100% SUBMISSION
11/18/2025
D110
N
M
O P A C
E X P R
E S S W
A Y
A U
S T
IN
T X
NO. DESCRIPTION
1 DEMO EXISTING CARPET TILE AND BASE COMPLETE.
2 EXTENT OF FLOORING AND WALL BASE DEMOLITION. CONTRACTOR SHALL NOT
DEMOLISH FLOORING OR BASE PAST THIS LINE.
3 EXISTING FLOORING AND WALL BASE SHALL REMAIN. CONTRACTOR SHALL ENSURE
THERE'S NO DAMAGE DURING CONSTRUCTION. SEE FLOORING FINISH PLAN FOR NEW
FLOORING TRANSITIONS.
4 DEMO EXISTING CERAMIC TILE AND BASE. EXISTING DOOR THRESHOLDS SHALL BE
REPLACED AS REQ'D.
5 DEMO EXISTING VINYL FLOORING AND BASE COMPLETE. EXISTING DOOR
THRESHOLDS SHALL BE REPLACED.
SCALE:D110 1/4" = 1'-0"
1 OVERALL DEMOLITION PLAN
1. IT IS THE INTENT OF THE DEMOLITION TO REMOVE ALL EXISTING CONSTRUCTION
WHICH CONFLICTS WITH THE INTENT OF NEW CONSTRUCTION AND EVERY
DEMOLITION DETAIL MAY NOT NECESSARILY BE COVERED ON THESE DRAWINGS.
CONTRACTOR SHALL INCLUDE ALL DEMOLITION WORK EVEN IF NOT SPECIFICALLY
CALLED FOR.
2. WHERE REMOVAL OF EXISTING WALLS, PARTITIONS, EQUIPMENT, ETC DISTURBS
EXISTING MECHANICAL, PLUMBING, AND ELECTRICAL SERVICES, CONTRACTOR
SHALL MAKE PERMANENT REVISION AS REQUIRED AND IF NECESSARY PROVIDE
TEMPORARY SERVICES TO AREAS NOT SCHEDULED FOR DEMOLITION AND
REMODELING.
3. WHERE FIXTURES, DOORS AND OTHER ITEMS ARE REMOVED FROM WALL AND/OR
RELOCATED - PATCH AND REPAIR WALLS TO MATCH EXISTING FINISH. AT WALLS
THAT HAVE PAINTED GYP, PATCH, TEXTURE AND PAINT TO MATCH SURROUNDING
WALL. FOR WALLS PATCH AND REPAIR TO RECEIVE NEW FINISH AS SCHEDULED.
4. CONTRACTOR SHALL MAKE EVERY EFFORT TO KEEP ALL EXISTING FIREPROOFING
ON STRUCTURE UNDISTURBED. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY
TO REAPPLY FIREPROOFING THAT MAY BE REMOVED OR DAMAGED DURING
CONSTRUCTION.
5. CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF ALL FIRE RATED WALL
ASSEMBLIES SHOWN ON PLANS AND THOSE FOUND IN THE FIELD.
6. ALL EQUIPMENT THAT WILL NEED TO BE SALVAGED WILL BE REMOVED BY OWNER
PRIOR TO DEMOLITION.
7. CONTRACTOR SHALL HAUL OFF ALL MATERIALS UPON COMPLETION OF
DEMOLITION.
8. FIELD VERIFY MEP FIXTURES AND EQUIPMENT LOCATIONS.
DEMOLITION RCP
GENERAL NOTES
DEMOLITION RCP
KEY NOTES
EXST'G OPEN WORK AREA
EXST'G OFFICE
EXST'G OFFICE
EXST'G OFFICE
EXST'G OFFICE
EXST'G OFFICE
EXST'G OFFICE
EXST'G OFFICE
EXST'G OFFICE
EXST'G OFFICE EXST'G OFFICE EXST'G OFFICE
EXST'G DATA
EXST'G
MECH/ELEC
EXST'G JANITOR
EXST'G STORAGE
EXST'G BREAK
ROOM
EXST'G WOMENSEXST'G MENS
EXST'G TRAINING
EXST'G TOILET
EXST'G TOILET
EXST'G
VESTIBULE
AREA OF
LIMITED SCOPE
AREA OF
LIMITED SCOPE
AREA OF
LIMITED SCOPE
architects & associates clk
615 N. Upper Broadway
Suite 1250
Corpus Christi, TX
78401-0750
SHEET NUMBER
JOB NO.
DRN. BY:
ISSUE DATE:
CKD. BY:
T H
IS
I
S T
O G
IV
E
N O
T
IC
E A
N D
V E
R T
IF
Y
T H
A T
T H
E T
E X
A S
B O
A R
D O
F A
R C
H
IT
E C
T U
R A
L E
X A
M
IN
E R
S
T B
A E
H
A S
J U
R
IS
D
IC
T
IO
N O
V E
R T
H E
P R
O F
E S
S
IO
N A
L P
R A
C T
IC
E
O F
A R
C H
IT
E
C T
U R
E I
N T
A T
E O
F T
E X
A S
C
O N
T A
C T
T H
E T
B A
E A
T
-3
-9
, w w w
.t b a e.
st a te .t x.
u s O
R W
R
IT
E T
O T
H E
T E
X A
S B
O A
R D
O F
A R
C H
IT
E
C T
U R
A L
E X
A M
IN
E
R S
, P .O
. B O
X
, A U
S T
IN
, T
E X
A S
-2
REVISIONS
11/18/2025
T E X A S W
O R K F O
R C E C
O M
M
IS
S
IO
N M
O P A C P
R
IN
T S
H O
P
202551
D TORRES
A RIOJAS
D E
M O
L I T I O
N R
C P
100% SUBMISSION
11/18/2025
D120
N
M
O P A C
E X P R
E S S W
A Y
A U
S T
IN
T X
NO. DESCRIPTION
1 DEMO EXISTING CEILING TILES.IT IS THE INTENT FOR EXISTING GRID SYSTEM TO
REMAIN. CONTRACTOR SHALL REPLACE ANY DAMAGE TO THE GRID DURING
CONSTRUCTION.
2 EXISTING LIGHTS SHALL REMAIN. SEE ADD ALTERNATE 01 FOR REPLACEMENT OF
LIGHT FIXTURES.
3 CONTRACTOR SHALL DEMO A PORTION OF EXISTING CEILING GRID AS REQUIRED TO
ADD STRUCTURAL SUPPORT AND DUCT RISER FOR NEW UNIT.
4 EXISTING CEILING TILES IN THIS AREA MAY NOT HAVE TO BE REMOVED FOR ABOVE
CEILING WORK. ANY TILES REMOVED, SHALL BE REPLACED WITH NEW.
SCALE:D120 1/4" = 1'-0"
1 OVERALL DEMO RCP
TO MOPAC
EXPRESSWAY
SERVICE ROAD
2EXISTING
BUILDING
5 6
1. ARCHITECTURAL SITE PLANS ARE FOR REFERENCE ONLY. SITE WORK IS NOT IN
THE SCOPE OF WORK.
2. CONTRACTOR SHALL ESTABLISH CONSTRUCTION AREA WITH PERIMETER FENCE
AS NEEDED DURING CONSTRUCTION. THE CONTRACTOR SHALL CAREFULLY
COORDINATE SITE ACCESS AND EMPLOYEE/CLIENT SAFETY FOR DURATION OF
CONSTRUCTION.
3. CONTRACTOR SHALL COORDINATE ON-SITE ACTIVITIES WITH TEXAS WORKFORCE
COMMISSION. IN THE EVENT THAT CONCURRENT PROJECTS ARE IN-PROGRESS ON
SITE, CONTRACTOR WILL HAVE TO MAKE ACCOMODATIONS FOR ADDITIONAL
WORK.
4. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO SECURE ALL MATERIALS ON
SITE.
SITE PLAN
GENERAL NOTES
SITE PLAN
KEY NOTES
architects & associates clk
615 N. Upper Broadway
Suite 1250
Corpus Christi, TX
78401-0750
SHEET NUMBER
JOB NO.
DRN. BY:
ISSUE DATE:
CKD. BY:
T H
IS
I
S T
O G
IV
E
N O
T
IC
E A
N D
V E
R T
IF
Y
T H
A T
T H
E T
E X
A S
B O
A R
D O
F A
R C
H
IT
E C
T U
R A
L E
X A
M
IN
E R
S
T B
A E
H
A S
J U
R
IS
D
IC
T
IO
N O
V E
R T
H E
P R
O F
E S
S
IO
N A
L P
R A
C T
IC
E
O F
A R
C H
IT
E
C T
U R
E I
N T
A T
E O
F T
E X
A S
C
O N
T A
C T
T H
E T
B A
E A
T
-3
-9
, w w w
.t b a e.
st a te .t x.
u s O
R W
R
IT
E T
O T
H E
T E
X A
S B
O A
R D
O F
A R
C H
IT
E
C T
U R
A L
E X
A M
IN
E
R S
, P .O
. B O
X
, A U
S T
IN
, T
E X
A S
-2
REVISIONS
11/18/2025
T E X A S W
O R K F O
R C E C
O M
M
IS
S
IO
N M
O P A C P
R
IN
T S
H O
P
202551
DT
AR
S I T E
P L A
N
100% SUBMISSION
11/18/2025
A100
N
M
O P A C
E X P R
E S S W
A Y
A U
S T
IN
T X
SCALE:A100 1" = 20'-0"
1 SITE PLAN
NO. DESCRIPTION
1 EXISTING SIDEWALK TO REMAIN. NOT IN SCOPE OF WORK.
2 EXISTING ASPHALT PAVING AND STRIPING TO REMAIN. NOT IN SCOPE OF WORK.
3 CONTRACTOR SET UP AND ACCESS AREA.
4 CONTRACTOR'S TEMPORARY PORTACAN FACILITIES.
5 NOTE: THERE IS NO EXTERIOR ACCESS TO THE ROOF.
6 CONTRACTOR IS RESPONSIBLE FOR ANY PERMITS REQUIRED BY CRANE OPERATOR.
CRANE LOCATION SHALL BE COORDINATED WITH TEXAS WORKFORCE COMMISSION.
D
C
B
A
S L O
P E
S L O
P E
ROOF HATCH
RTU-2 RTU-3
RTU-1 RTU-4
RIDGE
S L O
P E
CU CU
CU
VERIFY DIM
29' - 5"
V E
R
IF
Y D
IM
EF
EF
EF
EF
RD RD RD RD
RD RD RD RD
1. CONTRACTOR SHALL MAINTAIN ADEQUATE QUANTITIES OF EMERGENCY
PROTETION MATERIALS TO ENSURE THE FACILITY WILL BE KEPT DRY DURING THE
EQUIPMENT PLACEMENT. THE CONTRACTOR SHALL PROTECT UNFINISHED OR
OPEN ROOF WITH PROTECTION METERIALS.
2. CONTRACTOR SHALL PROTECT NEW ROOF SYSTEM INCLUDING CAP SHEET.
CONTRACTOR IS RESPONSIBLE TO ENSURE THAT INSTALLATION OF NEW HVAC
EQUIPMENT WILL NOT VOID THE EXISTING ROOF WARRANTY. CONTRACTOR SHALL
VERIFY WITH ROOFING MANUFACTURER STEPS REQUIRED TO MAINTAIN EXISTING
ROOF WARRANTY. UPON COMPLETION OF ALL WORK AFFECTING THE ROOFING
SYSTEM, CONTRACTOR MUST HAVE ROOF INSPECTED AND SIGNED OFF BY
ROOFING MANUFACTURER. A LETTER FROM MANUFACTURER ACCEPTING THE
WORK THAT HAS BEEN PERFORMED.
ROOF PLAN
GENERAL NOTES
ROOF PLAN
KEY NOTES
architects & associates clk
615 N. Upper Broadway
Suite 1250
Corpus Christi, TX
78401-0750
SHEET NUMBER
JOB NO.
DRN. BY:
ISSUE DATE:
CKD. BY:
T H
IS
I
S T
O G
IV
E
N O
T
IC
E A
N D
V E
R T
IF
Y
T H
A T
T H
E T
E X
A S
B O
A R
D O
F A
R C
H
IT
E C
T U
R A
L E
X A
M
IN
E R
S
T B
A E
H
A S
J U
R
IS
D
IC
T
IO
N O
V E
R T
H E
P R
O F
E S
S
IO
N A
L P
R A
C T
IC
E
O F
A R
C H
IT
E
C T
U R
E I
N T
A T
E O
F T
E X
A S
C
O N
T A
C T
T H
E T
B A
E A
T
-3
-9
, w w w
.t b a e.
st a te .t x.
u s O
R W
R
IT
E T
O T
H E
T E
X A
S B
O A
R D
O F
A R
C H
IT
E
C T
U R
A L
E X
A M
IN
E
R S
, P .O
. B O
X
, A U
S T
IN
, T
E X
A S
-2
REVISIONS
11/18/2025
T E X A S W
O R K F O
R C E C
O M
M
IS
S
IO
N M
O P A C P
R
IN
T S
H O
P
202551
DT
AR
R O
O F P
L A
N
100% SUBMISSION
11/18/2025
A101
N
M
O P A C
E X P R
E S S W
A Y
A U
S T
IN
T X
SCALE:A101 1/4" = 1'-0"
1 ROOF PLAN
NO. DESCRIPTION
1 NEW ERV UNIT AND CURB AS SPECIFIED. SEE MEP DRAWINGS FOR MORE
INFORMATION. SEE STRUCTURAL DRAWINGS FOR ROOF CURB DETAILS.SEE NOTES
REGARDING ROOFING WARRANTY.
2 EXISTING MODIFIED BIT ROOF SYSTEM. RECENTLY INSTALLED, UNDER WARRANTY.
SEE NOTES REGARDING WARRANTY REQUIREMENTS.
3 NEW ROOF PENETRATION TO ALLOW FOR NEW CONDENSATE DRAIN LINE. SEE MEP
DRAWINGS FOR MORE INFORMATION. SEE D2/A301 FOR ROOF PENETRATION
DETAILS. SEE D4/A301 FOR PIPE SUPPORT DETAIL.
4 CONTRACTOR TO INSTALL NEW WALKPAD AS SHOWN ON SHEET A300. SEE D3/A301
FOR DETAILS.
5 EXISTING ROOFTOP UNITS, GAS LINES, DRAIN LINES, AND ROOF COMPONENTS SHALL
REMAIN. CONTRACTOR SHALL ENSURE THAT THERE'S NO DAMAGE…
This is the start of the file's text. The full file is on GovTribe.