ECAT_BP2_DRAWING_SET_-_04_BUS_WASH_Rev_1__26-11-13.pdf

PDF 12 MB Posted

Attached to
CDBG-DR HS004 New Escambia County Area Transit (ECAT) Facility
Solicitation number
PD 26-27.004
Issued by
Escambia County, Florida

About this file

This file comprises structural design drawings and construction documents for the Bus Wash facility, one of five structures comprising the New Escambia County Area Transit (ECAT) Facility in Pensacola, Florida. The drawings, prepared by RLG Consulting Engineers and dated October 22, 2026 (Addendum 01 dated November 12, 2026), provide comprehensive structural, architectural, mechanical, plumbing, and electrical design details for a bus wash building located at 10 Clarinda Lane. The facility consists of a wash bay (101), equipment room (102), ADA restroom (103), fare processing area (104), fare entrance (105), and vacuum room (106), with auxiliary structures including dumpster enclosures. The building is approximately 93 feet 4 inches by 63 feet 4 inches in plan dimension with precast concrete plank roof systems and masonry wall construction. The design incorporates the Interclean XJ404 FF bus wash system, with detailed specifications for foundation design, concrete placement, reinforcing steel, masonry construction, HVAC systems, plumbing connections, and electrical distribution. The drawings reference compliance with the 8th Edition Florida Building Code, ACI 318 concrete standards, and ASCE 7-22 wind design criteria, with wind speeds of 156 mph basic and seismic design category B. Bid documents indicate a non-mandatory pre-bid meeting on October 29, 2026, with bids due November 23, 2026 at 10:00 a.m.; substantial completion is specified within 180 to 335 consecutive calendar days from Notice to Proceed, plus 30 days for final completion.

The project budget and funding details are referenced in the related solicitation as part of a CDBG-DR (HUD Community Development Block Grant-Disaster Recovery) funded initiative. Bidders may bid individual lots or complete package options, with pricing structured as a base bid with deductive alternates and unit prices for specific elements. All work is subject to Davis-Bacon wage requirements. Successful bidders must hold a current Florida General Contractor (CGC) or Underground Utility and Excavation Contractor (CUC) license, provide performance and payment bonds, submit a Quality Control Plan, and maintain insurance coverage of $2,000,000 combined general liability. Federal compliance requirements include suspension and debarment verification, domestic preference, recovered materials procurement, MBE/WBE affirmative steps, E-Verify, and environmental provisions for Eastern Indigo Snakes and Tricolored Bats. Liquidated damages follow the Florida Department of Transportation schedule. The apparent lowest responsive and responsible bidder must submit a detailed Schedule of Values within three business days of bid opening for Florida Department of Commerce review before award authorization.

View the file

Other files

File Type Posted
CDBG-DR_HS004_New_Escambia_County_Area_Transit_(ECAT)_Facility_(Addendum_#16_Revision).pdf PDF
ECAT_BP2_CONSTRUCTION_ADD-REV_1_WRITE-UP_Rev_1__26-11-13.pdf PDF
ECAT_BP2_PROJECT_MANUAL_Rev_1__26-11-13.pdf PDF
ECAT_BP2_DRAWING_SET_-_05_FUEL_STATION_Rev_1__26-11-13.pdf PDF
ECAT_BP2_DRAWING_SET_-_03_TRANSFER_CENTER_Rev_1__26-11-13.pdf PDF
ECAT_BP2_DRAWING_SET_-_02_MAINTENANCE_BUILDING_Rev_1_26-11-13.pdf PDF
ECAT_BP2_DRAWING_SET_-_01_ADMINISTRATION_BUILDING_Rev_1_26-11-13.pdf PDF
ECAT_BP2_DRAWING_SET_-_00_SITE_SITE_Rev_1_26-11-13.pdf PDF
CDBG-DR_HS004_New_Escambia_County_Area_Transit_(ECAT)_Facility_(Addendum_#10_Revision).pdf PDF
CDBG-DR_HS004_New_Escambia_County_Area_Transit_(ECAT)_Facility_(Addendum_#9_Revision).pdf PDF
CDBG-DR_HS004_New_Escambia_County_Area_Transit_(ECAT)_Facility_(Addendum_#8_Revision).pdf PDF
CDBG-DR_HS004_New_Escambia_County_Area_Transit_(ECAT)_Facility.pdf PDF
ECAT_BP2_PROJECT_MANUAL_-_VOLUME_TWO.pdf PDF
ECAT_BP2_PROJECT_MANUAL_-_VOLUME_ONE.pdf PDF
ECAT_BP2_DRAWING_SET_-_05_FUEL_STATION.pdf PDF
ECAT_BP2_DRAWING_SET_-_04_BUS_WASH.pdf PDF
ECAT_BP2_DRAWING_SET_-_03_TRANSFER_CENTER.pdf PDF
ECAT_BP2_DRAWING_SET_-_02_MAINTENANCE_BUILDING.pdf PDF
ECAT_BP2_DRAWING_SET_-_01_ADMINISTRATION_BUILDING.pdf PDF
ECAT_BP2_DRAWING_SET_-_00_SITE.pdf PDF
FDOT_Liquidated-Damages-2026-2027.pdf PDF
Building_Construction_Wage_Determination_5.18.26.pdf PDF
Exhibit.FederalContractProvisions.HUD_10.22.26.pdf PDF
Escambia_County_Section_3_Business_Application_CDBG-DR.pdf PDF
Section-3-project-implementation-plan-template---forms-0-8.pdf PDF
Escambia_County_Section_3_Contract_Clause_CDBG-DR.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DESIGN DATA

1. THE DESIGN OF THE STRUCTURE AND PARTS THEREOF IS IN ACCORDANCE WITH THE 8TH EDITION OF FLORIDA BUILDING

CODE, AS AMENDED AND ADOPTED BY ESCAMBIA COUNTY .

2. FLOOR LIVE LOADS.

AREA UNIFORM CONCENTRATED

OFFICES

IMPACT LIVE LOAD REDUCTION

50 psf 2.0 -kips

OFFICE CORRIDORS 1ST FLOOR 2.0 -kips

- kipsASSEMBLY AREAS -

STORAGE HEAVY - kips

STORAGE LIGHT -

kips -

100 psf

100 psf

250 psf

125 psf

3. ROOF LIVE LOADS:

AREA UNIFORM SPECIAL COMMENTS

ROOF, GENERAL

LIVE LOAD REDUCTION

20 psf -

ROOF, EQUIP LOADS SEE ROOF PLAN

4. SNOW LOADS: NOT APPLICABLE PER FBC

5. WIND DESIGN DATA:

ASD WIND SPEED Vasd 121 mph

RISK CATEGORY

BASIC WIND SPEED (3 SECOND GUST)

WIND EXPOSURE

INTERNAL PRESSURE COEFFICIENT

COMPONENTS AND CLADDING

156 mph

+/- 0.55

PER ASCE 7-22

FACTORED COMPONENTS AND CLADDING WALL LOADS

POSITIVE PRESSURE (psf) NEGATIVE PRESSURE (psf)

AREA (SQ FT)

LESS THAN 10

GREATER THAN 500

INTERIOR AND CORNER ZONE INTERIOR ZONE CORNER ZONE

-57

-52

-47

-44 -44

-51

-60

-71

CORNER ZONE IS A DISTANCE OF 3'-0" FROM WALL CORNERS

LINEAR INTERPOLATE FOR LOADS BETWEEN SPECIFIED AREAS

7. FLOOD DESIGN DATA:

THIS PROJECT IS NOT LOCATED WITHIN A FLOOD HAZARD AREA

8. SPECIAL LOADS:

VEHICULAR BARRIERS

AREA

AWNINGS & CANOPIES

UNIFORM

20 psf

6.0 ksf

CONCENTRATED

300 lbs.

IMPACT SECTION OF CODE

FBC 1607.9

FBC 1607.13.4

FACTORED COMPONENTS AND CLADDING ROOF LOADS

POSITIVE PRESSURE (psf) NEGATIVE PRESSURE (psf)

AREA (SQ FT)

LESS THAN 10

GREATER THAN 500

PERIMETER ZONE, "B" IS A DISTANCE OF 12'-0" FROM EDGE OF BUILDING

CORNER ZONE, "C" IS A DISTANCE OF 4'-0" FROM EDGE OF BUILDING

ALL ZONES 2 & 3 ZONE 2

-119

-93

-86

-76

ZONE 3

-162

-111

-96

-76

LINEAR INTERPOLATE FOR LOADS BETWEEN SPECIFIED AREAS

3 3

B

B

C

ROOF WIND LOAD LAYOUT

YES, PER FBC 1607.13.1

YES, PER FBC 1607.13.1

YES, PER FBC 1607.13.1

YES, PER FBC 1607.13.1.2

YES, PER FBC 1607.13.1.2

YES, PER FBC 1607.14

N/A

N/A

TORNADO SPEED, Vt

EFFECTIVE PLAN AREA

II

C

9. ROOF RAIN LOAD DATA:

RAIN INTENSITY (15-DURATION)

4.9 in/hrRAIN INTENSITY (60-DURATION)

9.12 in/hr

6. SEISMIC DESIGN DATA:

SEISMIC IMPORTANCE FACTOR, Ie

MAPPED SPECTRAL RESPONSE ACCEL.

RISK CATEGORY

SITE CLASS

SPECTRAL RESPONSE COEFFICIENTS

SEISMIC DESIGN CATEGORY

Ss =

BASIC SEISMIC-FORCE-RESISTING SYSTEM

DESIGN BASE SHEAR

SEISMIC RESPONSE COEFFICIENT, Cs

RESPONSE MODIFICATION FACTOR, R

ANALYSIS PROCEDURE USED

SDS =

S1 =

SD1 =

0.11 0.063

0.090.1

0.07xW

1.0

II

DEFAULT

B

ORDINARY PLAN MASONRY SHEAR

WALL

0.07

1.5

EQUIVALENT LATERAL FORCE

1. PROJECT SPECIFICATIONS ARE A PART OF THE CONTRACT DOCUMENTS. CONTRACTOR SHALL REVIEW THE SPECIFICATIONS AND NOTIFY ARCHITECT OF DISCREPANCIES BEFORE PROCEEDING WITH WORK.

2. STRUCTURAL DRAWINGS ARE AN INTEGRAL COMPONENT TO THE CONTRACT DOCUMENTS. CONTRACTOR SHALL

REVIEW AND COORDINATE ACCORDINGLY.

A. PRIOR TO FABRICATION OR INSTALLATION OF STRUCTURAL MEMBERS, CONTRACTOR SHALL COMPARE

STRUCTURAL DIMENSIONS AND SECTIONS WITH ARCHITECTURAL DIMENSIONS AND SECTIONS.

DISCREPANCIES ARE TO BE REPORTED IN WRITING TO THE ARCHITECT.

B. PRINCIPAL OPENINGS ARE SHOWN ON THESE DRAWINGS. REFER TO ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR OTHER OPENINGS NOT SHOWN.

C. REFER TO ARCHITECTURAL DRAWINGS FOR ELEVATIONS AND LOCATIONS OF SLAB DEPRESSIONS AND

CURBS NOT SHOWN. PROVIDE POSITIVE SLOPE TO ALL DRAINS.

D. CONTRACTOR SHALL COORDINATE PENETRATIONS, SLEEVES, CURBS, AND INSERTS REQUIRED FOR THE

CONTRACT DOCUMENTS.

E. CONTRACTOR SHALL VERIFY SIZE, WEIGHT, LOCATION, AND SUPPORT CONDITIONS OF MECHANICAL

EQUIPMENT SUPPORTED ON OR SUSPENDED FROM THE ROOF OR FLOORS.

F. CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ADJACENT STRUCTURES AND UTILITIES.

G. CONTRACTOR SHALL NOTIFY IN WRITING THE ARCHITECT & ENGINEER OF ANY DISCREPANCIES BEFORE

PROCEEDING WITH WORK.

3. TEMPORARY SHORING AND BRACING DURING CONSTRUCTION

A. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING OF COMPONENTS DURING CONSTRUCTION TO MEET

REGULATORY REQUIREMENTS FOR SAFETY.

B. CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND BRACING OF WALLS AND GRADE BEAMS DURING

CONSTRUCTION. SHORE WALLS AND GRADE BEAMS DURING THE BACKFILLING AND COMPACTION PROCESS.

C. CONTRACTOR SHALL PROVIDE NECESSARY TEMPORARY BRACING AND SHORING DURING CONSTRUCTION

UNTIL STRUCTURAL FRAMING AND DIAPHRAGMS ARE COMPLETED. TEMPORARY BRACING SHALL BE

DESIGNED UNDER THE SUPERVISION OF A LICENSED ENGINEER.

4. SELECTION OF CONSTRUCTION MEANS, METHODS, TECHNIQUES, AND PROCEDURES, AS WELL AS SAFETY PRECAUTIONS AND PROGRAMS, ARE SOLELY THE CONTRACTOR’S RESPONSIBILITIES. AS SUCH, CONSTRUCTION ENGINEERING AND DESIGN RESULTING FROM THESE SELECTIONS IS THE RESPONSIBILITY OF THE CONTRACTOR.

A. EXAMPLES INCLUDE, BUT ARE NOT LIMITED TO, ENGINEERING OF SHORING AND SCAFFOLDING SYSTEMS;

LOAD CHECKS AND STRUCTURAL MODIFICATIONS FOR STORAGE, STAGING, AND CONSTRUCTION

EQUIPMENT LOADING; MEANS OF EGRESS FOR HEAVY EQUIPMENT; CRANE SELECTION, LOCATION, SUPPORT

AND BRACING; TEMPORARY HOISTS, LIFTS AND PLATFORMS.

B. CONTRACTOR SHALL ENSURE THAT APPROPRIATE ENGINEERING IS PERFORMED BY A LICENSED ENGINEER FOR THE WORK, CONSULTED WITH ON FIELD MODIFICATIONS, SPECIFY APPROPRIATE LEVELS OF

INSPECTION OF THE WORK, AND TO REVIEW INSPECTION REPORTS.

C. CONSTRUCTION ENGINEERING FEES HAVE NOT BEEN INCLUDED IN THE BASE FEE TO THE

OWNER/ARCHITECT. IF REQUESTED, THE EOR MAY CONSIDER PERFORMING THESE SERVICES AS AN

ADDITIONAL SERVICE PAID BY THE CONTRACTOR.

5. PRE-CONSTRUCTION MEETINGS SHALL BE CONDUCTED TO DISCUSS SUBGRADE PREPARATION, FOUNDATION CONSTRUCTION, WALL BACKFILL, VOID FORM SYSTEMS, CONCRETE FORMING & PLACING, AND TESTING &

INSPECTION REQUIREMENTS.

6. CONTRACTOR SHALL COMPLY WITH REQUIREMENTS AS LISTED IN THE STATEMENT OF SPECIAL INSPECTIONS.

GENERAL NOTES

1. DEFERRED SUBMITTALS ARE PORTIONS OF THE OVERALL DESIGN WHICH ARE NOT SUBMITTED AT TIME OF PERMIT

APPLICATION AND ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL.

2. DEFERRED SUBMITTALS WILL BE REVIEWED FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. SUBMITTAL REVIEW WILL NOT BE CONDUCTED FOR THE PURPOSE OF DETERMINING THE ACCURACY AND COMPLETENESS OF OTHER DETAILED INFORMATION SUCH AS DIMENSIONS AND QUANTITIES, OR FOR SUBSTANTIATING INSTRUCTIONS FOR INSTALLATION OR SYSTEMS DESIGNED

BY THE CONTRACTOR WHICH REMAINS THE RESPONSIBILITY OF THE CONTRACTOR.

REVIEW SHALL NOT CONSTITUTE APPROVAL OF SAFETY PRECAUTIONS OR OF ANY CONSTRUCTION MEANS, METHODS, SEQUENCES OR PROCEDURES.

APPROVAL OF A SPECIFIC ITEM SHALL NOT INDICATE APPROVAL OF AN ASSEMBLY OF WHICH THE ITEM IS A

COMPONENT.

3. FOLLOWING DEFERRED SUBMITTALS ARE TO BE PROVIDED FOR REVIEW:

A. CONCRETE FORMWORK / RETENTION SYSTEMS

B. PRECAST CONCRETE PLANKS (SIGNED AND SEALED CALCULATIONS AND DRAWINGS)

SUPPLIER’S ENGINEERS SHALL PROVIDE SIGNED AND SEALED CALCULATIONS WITH THE SUBMITTAL FOR REVIEW.

REVIEW WILL BE LIMITED TO CONFORMANCE WITH DESIGN AND PERFORMANCE CRITERIA SPECIFIED IN THE CONSTRUCTION DOCUMENTS AND THE INTERFACE BETWEEN THESE ITEMS/SYSTEMS AND THE BUILDING STRUCTURE. THE MANUFACTURER/SUPPLIER AND ITS SPECIALTY STRUCTURAL ENGINEER REMAIN RESPONSIBLE FOR THE DESIGN OF THE ITEM/SYSTEM WILL RETAIN ALL RIGHTS AND RESPONSIBILITIES FOR THE DESIGN OF THE

PRODUCT AND THE CONNECTIONS TO THE BUILDING STRUCTURE.

NO WORK ON STRUCTURAL ELEMENTS SUPPORTING OR RELATED TO THESE ITEMS IS TO PROCEED UNLESS THE REVIEW STAMP CLEARLY INDICATES "REVIEWED" OR "REVIEWED, SEE COMMENTS" BY THE ENGINEER.

4. FOLLOWING SHOP DRAWINGS ARE TO BE PROVIDED FOR APPROVAL:

A. CONCRETE MIXES

B. REINFORCING STEEL

C. MASONRY WALL REINFORCING

SHOP DRAWINGS ARE TO BE DISTRIBUTED ONLY FROM RETURNED SUBMITTALS BEARING AN INITIALED REVIEW STAMP AND WORK ON THESE ITEMS SHALL NOT PROCEED UNLESS THE STAMP CLEARLY INDICATES THE DRAWINGS

ARE "APPROVED" OR "APPROVED AS NOTED."

5. CONCRETE IS A MATERIAL DESIGNED BY THE SUPPLIER TO MEET THE STRENGTH AND PERFORMANCE CRITERIA SPECIFIED IN THE CONTRACT DOCUMENTS. CONCRETE MIX DESIGNS SHALL BE IN CONFORMANCE WITH ACI 318.

SUBMIT MIX DESIGNS AND THE TESTING LAB REVIEW TO THE ARCHITECT/ENGINEER FOR REVIEW.

MANY VARIABLES, INCLUDING ENVIRONMENTAL CONDITIONS AFFECT THE QUALITY OF CONCRETE. THE CONTRACTOR IS RESPONSIBLE FOR CONTROLLING VARIABLES AND REQUESTING MIX MODIFICATIONS AND SHALL BE

SOLELY RESPONSIBLE FOR THE QUALITY OF CONCRETE DELIVERED AND PLACED ON THE SITE.

6. BEFORE SUBMISSION FOR REVIEW, GENERAL CONTRACTOR SHALL PRE-CHECK SUBMITTALS. SUBMITTALS MUST BEAR AN INITIALED REVIEW STAMP OF THE GENERAL CONTRACTOR. SUBMITTALS WITHOUT REVIEW STAMPS WILL

BE RETURNED WITHOUT REVIEW AND SHALL NOT BE CAUSE FOR CLAIMS OF DELAY.

7. SCHEDULE SUBMITTALS SUFFICIENTLY IN ADVANCE OF THE DATE REQUIRED TO ALLOW REASONABLE TIME FOR PROCESSING AND REVIEW BY THE DESIGN TEAM. THIS SHALL INCLUDE A MINIMUM OF TEN WORKING DAYS FOR ENGINEER'S PROCESSING AND REVIEW. INCLUDE TIME FOR CONTRACTOR’S RESUBMISSION AND SUBSEQUENT

REVIEW IF NECESSARY.

SHORTER REVIEW PERIODS WILL ONLY BE HONORED WITH PRIOR WRITTEN CONSENT. THESE ACCELERATED SERVICES, AND APPROPRIATE COMPENSATION, MUST BE NEGOTIATED WITH THE ENGINEER AND ARCHITECT IN

ADVANCE.

TEN DAY REVIEW PERIODS CAN NOT BE HONORED WHEN LARGE QUANTITIES OF SHOP DRAWINGS ARE SUBMITTED AT ONE TIME. WHEN THIS HAPPENS, THE CONTRACTOR SHALL SUBMIT AN ITEMIZED LIST INDICATING PRIORITIES AND

REASONABLE RETURN DATES.

REVIEW OF RESUBMITTALS WILL BE LIMITED TO ONLY EARLIER COMMENTS AND IS NOT AN EXTENSIVE REVIEW.

8. USE OF REPRODUCTIONS OF THESE CONTRACT DRAWINGS, INCLUDING THE USE OF ELECTRONIC FILES, BY ANY CONTRACTOR IN LIEU OF THE INDEPENDENT PREPARATION OF SHOP DRAWINGS, SIGNIFIES THEIR ACCEPTANCE OF ALL INFORMATION SHOWN HEREON AS CORRECT AND OBLIGATES HIMSELF TO ANY JOB EXPENSE, REAL OR IMPLIED, ARISING DUE TO ANY ERRORS THAT MAY OCCUR HEREON.

9. NOT USED

DEFERRED SUBMITTALS NOTES

1. FOUNDATION DESIGN AND SUBSURFACE INFORMATION IS BASED ON GEOTECHNICAL REPORT #26-162 PREPARED FOR THIS PROJECT BY LARRY M JACOBS & ASSOCIATES, INC AND DATED MAY 1, 2026 & EMAIL RESPONSE DATED

SEPTEMBER 1, 2026.

2. GEOTECHNICAL ENGINEER OF RECORD (GER) IS SOLELY RESPONSIBLE FOR ESTABLISHING FOUNDATION, SLAB-ON- GRADE AND PAVEMENT DESIGN CRITERIA, AND FOR THE CONSTRUCTION RECOMMENDATIONS FOR EXCAVATION, SUBGRADE PREPARATION, BACKFILLING AND COMPACTION.

3. GEOTECHNICAL INFORMATION INDICATED IN THE STRUCTURAL CONSTRUCTION DOCUMENTS IS INTENDED TO REPLICATE THE RECOMMENDATIONS STATED IN THE GEOTECHNICAL ENGINEERING REPORT. PRESENTATION OF THIS INFORMATION IN THE STRUCTURAL DOCUMENTS DOES NOT DEMONSTRATE, STATE OR IMPLY GEOTECHNICAL EXPERTISE BY THE STRUCTURAL ENGINEER. CONTRACTOR SHALL OBTAIN A COPY OF THE REPORT AND COMPLY

WITH THE RECOMMENDATIONS INDICATED THEREIN.

4. IF DISCREPANCIES BETWEEN THE REPORT AND CONSTRUCTION DOCUMENTS ARE DISCOVERED, THE REPORT SHALL GOVERN. ALL CLARIFICATIONS AND INTERPRETATIONS OF THE REPORT SHALL BE MADE BY THE GER AND

REPORTED TO THE ARCHITECT FOR COORDINATION WITH THE DESIGN TEAM.

GEOTECHNICAL INFORMATION

1. BEARING STRATA SHOWN ON THE DETAILS IS COMPACTED NATIVE SOIL. PREPARE FOUNDATION BEARING MATERIAL

PER THE GEOTECHNICAL ENGINEER'S RECOMMENDATIONS.

2. FOUNDATION ALLOWABLE DESIGN SOIL VALUES:

CONTINUOUS FOOTING BEARING - 1.5ksf * ISOLATED FOOTING BEARING - 1.5ksf *

SOIL SLIDING RESISTANCE (NATIVE SOIL) 0.5

* IF CONTINUOUS FOOTING OR ISOLATED FOOTING WIDTH EXCESS 3FT IN DIMENSION, THE SOIL BENEATH FOOTING

SHALL HAVE ADDITIONAL 2FT OF SOIL COMPACTION PER GEOTECHNICAL REPORT.

RETAINING WALL DESIGN VALUES

SOIL DENSITY Yd- 95PCF (VERY LOOSE SLIGHTLY SILTY SAND) AT REST Ka- 0.4xYd PASSIVE PRESSURE Kp- 2.5XYd

3. ALL FOOTING EXCAVATIONS SHALL BE CLEANED TO REMOVE ALL LOOSE SOIL MATERIAL AND OTHER DEBRIS AND

SHOULD NOT BE ALLOWED TO DESICCATE PRIOR TO PLACEMENT OF CONCRETE.

4. CONCRETE FOR FOUNDATIONS SHALL BE FORMED ON THE SIDES (EARTH FORMED FOUNDATIONS WILL NOT BE

ALLOWED). PROPERLY PLACE AND COMPACT FILL MATERIAL AROUND SIDES OF FOOTINGS.

5. ALL FOUNDATION EXCAVATIONS SHALL BE INSPECTED BY THE TESTING AGENCY.

SHALLOW FOUNDATION NOTES

1. FLOOR SLAB SHALL BE 8" THICK CONCRETE SLAB OVER A 15 MIL VAPOR RETARDER, OVER SUBGRADE PREPARED PER THE GEOTECHNICAL ENGINEER'S RECOMMENDATIONS. TAPE ALL SEAMS, PENETRATIONS AND TEARS IN

THE VAPOR RETARDER WITH A COMPATIBLE WATERPROOF TAPE.

2. REINFORCE SLAB WITH #4 @ 12" CTRS. EACH WAY PLACED AND SUPPORTED ON CHAIRS OR CONCRETE BRIQUETS, AT SLAB MID DEPTH.

3. PROVIDE ONE OF THE FOLLOWING JOINTS ON THE CENTERLINE OF ALL COLUMNS, AND @ 15' O.C. MAXIMUM.

A. CONSTRUCTION JOINTS WHERE DETAILED ON DRAWINGS.

B. SAW CUT CONTROL JOINTS ELSEWHERE 2" DEEP OR ONE QUARTER OF THE SLAB DEPTH DEEP, WHICHEVER IS GREATER.

4. CUT SAW CUT JOINTS WITHIN 8 HOURS OF POURING CONCRETE.

5. CONCRETE FINISHES AND SPRAY ON CURRING / SEALING COMPOUNDS SHALL BE COORDINATED WITH

ARCHITECTURAL FLOORING FINISHES FOR COMPATIBILITY.

SLAB-ON-GRADE NOTES

1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 318- PER GOVERNING BUILDING CODE.

2. CONCRETE IN THE FOLLOWING AREAS SHALL HAVE SAND AND GRAVEL OR CRUSHED STONE AGGREGATES AND THE DESIGNATED COMPRESSIVE STRENGTH IN 28 DAYS UNLESS NOTED OTHERWISE. NORMAL WEIGHT AGGREGATES

SHALL CONFORM TO ASTM C33.

FOOTING AND SLABS ON GRADE --------------------------- f'c = 4,000 psi ALL OTHER CONCRETE ---------------------------------------- f'c = 4,000 psi

3. CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE AS FOLLOWS:

REFER TO ACI 318 - SECTION 7.7 FOR CONDITIONS NOT NOTED.

FOOTINGS ---------------------------------------- 3"

SLABS-ON-GRADE ----------------------------- CENTERED

4. MAXIMUM NOMINAL COARSE AGGREGATE SIZE SHALL BE 1 1/2" MAX FOR PIERS AND 1" MAX TYPICAL UNLESS NOTED

OTHERWISE.

5. CONCRETE SLUMPS SHALL BE AS FOLLOWS:

CONCRETE CONTAINING HRWR------ 10" MAX

ALL OTHER CONCRETE ---------------- 5" MAX, 2" MIN

6. CONCRETE EXPOSED TO WEATHER SHALL BE AIR-ENTRAINED AS FOLLOWS:

3/4" NOMINAL AGGREGATE SIZE 4% TO 8%

1" NOMINAL AGGREGATE SIZE 3.5% TO 6.5%

1 1/2" NOMINAL AGGREGATE SIZE 3% TO 6%

7. ALL FOUNDATIONS AND CAST IN PLACE WALLS SHALL BE FORMED ON SIDES. ALL ELEMENTS OF THE FORMS, FORMWORK, BRACING AND SHORING SHALL CONSIST OF WOOD, METAL OR OTHER MANUFACTURED PRODUCTS AS SPECIFIED. EARTH MAY NOT BE USED AS A FORM, EITHER DIRECTLY OR INDIRECTLY. NEITHER EARTH TRENCHES

NOR EARTH TRENCHES LINED WITH ANOTHER MATERIAL ARE ACCEPTABLE.

8. THERE SHALL BE NO HORIZONTAL CONSTRUCTION JOINTS IN CONCRETE POURS. ALL CONSTRUCTION JOINTS SHALL BE MADE IN THE CENTER OF SPANS WITH VERTICAL BULK HEADS. THE LOCATION OF CONSTRUCTION JOINTS SHALL

BE APPROVED BY THE STRUCTURAL ENGINEER.

9. ALL CONSTRUCTION JOINTS SHOWN ON THE DRAWINGS SHALL BE INCORPORATED IN THE STRUCTURE UNLESS OTHERWISE APPROVED BY THE ENGINEER OF RECORD. ADDITIONAL CONSTRUCTION JOINTS REQUIRED TO FACILITATE CONSTRUCTION SHALL BE LOCATED AND DETAILED ON SHOP DRAWINGS. WHEN CONSTRUCTION JOINTS OTHER THAN THOSE SHOWN ON THE CONSTRUCTION DOCUMENTS ARE REQUIRED, THE REINFORCEMENT SHALL PASS CONTINUOUSLY THROUGH JOINT AND A KEY SHALL BE PROVIDED FOR ADEQUATE SHEAR TRANSFER.

10. UNLESS OTHERWISE NOTED OR DETAILED, PROVIDE (2)#5, (1) EACH FACE AROUND UNFRAMED OPENINGS IN CONCRETE WALLS AND GRADE BEAMS. PLACE BARS PARALLEL TO SIDES OF OPENINGS AND EXTEND 24 INCHES

BEYOND CORNERS.

11. PROVIDE EQUIPMENT BASES AND SUPPORTS AS REQUIRED, COMPLYING WITH APPROVED MANUFACTURERS

CERTIFIED SHOP DRAWINGS AND DETAILS.

12. SIZE AND LOCATION OF BASES AND EMBEDDED ANCHORS FOR EQUIPMENT SHALL BE COORDINATED WITH

EQUIPMENT SUPPLIER AND ALL BE IN ACCORDANCE WITH APPROVED SHOP DRAWINGS.

13. NO ALUMINUM OF ANY TYPE SHALL BE ALLOWED IN THE CONCRETE WORK, UNLESS COATED AND APPROVED BY

THE ENGINEER OR RECORD.

14. NO ELECTRICAL CONDUIT SHALL BE PLACE ABOVE THE WELDED WIRE FABRIC IN THE SLAB-ON-GRADE OR CONCRETE PLACED ON COMPOSITE METAL DECK. MAXIMUM SIZE OF CONDUIT SHALL BE 1/3 THE SLAB THICKNESS (ABOVE DECK ON COMPOSITE SLAB) INCLUDING CROSSOVERS. CONDUIT SHALL NOT BE PLACED CLOSER THAN 3

DIAMETERS ON CENTER.

CONCRETE NOTES

1. THE DESIGN AND ERECTION OF PRECAST CONCRETE COMPONENTS SHALL BE THE RESPONSIBILITY OF THE PRECAST FABRICATOR. THE FABRICATOR'S SHOP DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED FOR REVIEW AND SHALL BEAR THE SEAL OF A REGISTERED PROFESSIONAL ENGINEER IN THE STATE OF THE PROJECT, AND SHALL BE IN ACCORDANCE WITH ACI 318, AND PCI MNL 120 - PCI DESIGN HANDBOOK.

2. THE FABRICATOR SHALL DESIGN ALL PRECAST UNITS TO SUPPORT THE LIVE AND DEAD LOADS INDICATED ON PLANS AND DETAILS. REFER TO PLANS AND DETAILS FOR AREAS REQUIRING THICKER TOPPINGS. DESIGN ALL UNITS SUCH THAT NO SHORING WILL BE REQUIRED DURING CONSTRUCTION. LIMIT DEFLECTIONS TO THE STANDARDS SET FORTH IN ACI 318 FOR STRUCTURES SUPPORTING ELEMENTS LIKELY TO BE DAMAGED BY LARGE DEFLECTIONS.

3. THE FABRICATOR SHALL USE THE FOLLOWING WEIGHTS OF BUILDING MATERIALS TO DETERMINE ACTUAL LOADING

CONDITIONS:

NORMAL WEIGHT CONCRETE 150 pcf LIGHTWEIGHT CONCRETE 120 pcf

4. IN ADDITION TO THE LIVE AND DEAD LOADS INDICATED ON PLANS AND DETAILS, PRECAST COMPONENTS SHALL BE DESIGNED TO SUPPORT A 15 psf SUPERIMPOSED DEAD LOAD + MECHANICAL EQUIPMENT LOADING SHOWN ON PLAN

AND ROOF FALL PROTECTION SYSTEM.

5. NO ROOF LIVE LOAD REDUCTION SHALL BE ALLOWED.

6. TYPICAL ROOF UNITS SHALL BE 8" DEEP X 24" OR 48" WIDE SEE PLAN. UNITS SHALL BE FABRICATED FROM NORMAL WEIGHT CONCRETE WITH A 28 DAY COMPRESSIVE STRENGTH = 5000 psi AND A RELEASE STRENGTH OF 3500 psi.

7. UNITS HAVE BEEN LAID OUT USING THE 24" OR 48 " WIDTH AS TYPICAL. PROVIDE SPECIAL WIDTH UNITS AND FILLERS AS REQUIRED TO COMPLETE THE FLOOR AND ROOF SYSTEM. ALTERNATE UNIT WIDTHS WILL BE CONSIDERED PROVIDED THE CONTRACTOR COORDINATES REVISIONS TO THE SYSTEM WITH THE DESIGN TEAM AND ALL

APPROPRIATE SUB CONTRACTORS.

8. FABRICATOR SHALL DESIGN UNITS TO ACCOMMODATE OPENINGS SHOWN ON STRUCTURAL DRAWINGS AND SHALL REFER TO MECHANICAL, ELECTRICAL, ETC. FOR ADDITIONAL OPENINGS IN UNITS. FABRICATOR MAY PROPOSE

STEEL HEADERS WHERE APPROPRIATE, BUT SHALL COORDINATE THEM WITH ARCHITECT.

9. ALL TEMPORARY BRACING AND SHORING DURING ERECTION OF PRECAST ELEMENTS IS THE RESPONSIBILITY OF THE CONTRACTOR. ALL BRACING IS TO REMAIN IN PLACE UNTIL THE FLOOR AND ROOF DECKS HAVE ATTAINED

DESIGN STRENGTH AND DIAPHRAGM CONNECTIONS HAVE BEEN COMPLETED.

10. UNLESS NOTE OTHERWISE, ALL PRECAST/PRESTRESSED CONCRETE SHALL BE SUPPLIED BY A "PCI CERTIFIED

PLANT"

11. ALL PRECAST / PRESTRESSED MEMBERS SHALL BE OF SIZE, SHAPE, AND SPAN INDICATED ON THE DRAWINGS. ALL UNITS SHALL BE CAPABLE OF SUPPORTING THE SUPERIMPOSED DEAD AND LIVE LOADS AS SHOWN ON THE

DOCUMENTS, PLUE THE SELFWEIGHT OF THE PRECAST MEMBERS.

12. MANUFACTURER SHALL SUBMIT COMPLETE DESIGN CALCULATIONS FOR RECORD THAT ARE PREPARED B A LICENSED STRUCTURAL ENGINEER IN THE STATE OF FLORIDA FOR ALL PRECAST / PRESTRESSED CONCRETE

MEMBERS.

13. FIELD CUT HOLES FOR OPENINGS THAT DO NOT DISTURB PRESTRESSING STRANDS IN ACCORDANCE WITH THE PRESTRESSED UNIT MANUFACTURER'S INSTRUCTIONS. VERIFY SIZE AND LOCATION OF HOLES AND SLEEVES WITH

ALL APPLICABLE TRADES.

14. PRECAST MANUFACTURER SHALL COORDINATE WITH ARCHITECTURAL AND MECHANICAL DRAWINGS FOR REQUIRED

OPENINGS INCLUDING BUT NOT LIMITED TO OPENING SIZE AND LOCATIONS.

PRECAST CONCRETE NOTES

1. STRUCTURAL MASONRY SHALL CONFORM TO "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES" ACI

530 / ASCE 5 - LATEST EDITION.

2. HOLLOW LOAD BEARING MASONRY UNITS SHALL CONFORM TO ASTM C90, LIGHTWEIGHT, TYPE N, WITH A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 1900 psi ON THE NET AREA OF THE BLOCK. DESIGN BASED ON AN ULTIMATE COMPRESSIVE STRENGTH f'm = 2500 psi.

3. MORTAR SHALL CONFORM TO ASTM C270, TYPE M OR S.

4. GROUT SHALL CONFORM TO ASTM A476 WITH A MINIMUM COMPRESSIVE STRENGTH OF 2500 psi. USE COARSE GROUT IN TYPICAL APPLICATION. USE FINE GROUT IN 4" AND 6" CMU WALLS AND IN ANY CELL REINFORCED WITH

MORE THAN ONE BAR.

5. REFER TO REINFORCING STEEL NOTES FOR REINFORCEMENT USED IN MASONRY CONSTRUCTION. ALL REINFORCING TO BE GRADE 60. PRIOR TO FABRICATION SUBMIT SHOP DRAWINGS FOR REVIEW, INCLUDING WALL

ELEVATIONS SHOWING ALL REINFORCING STEEL.

6. VERTICAL REINFORCING SHALL BE #6 BARS AT A MAXIMUM SPACING OF 40" O.C., UNLESS OTHERWISE NOTED ON DRAWINGS. THE FIRST CELL AT CORNERS AND ENDS OF WALLS SHALL BE REINFORCED WITH 1-#6 BAR AND GROUTED FULL. ON EACH SIDE OF WALL OPENINGS 2-#5 BAR EXTENDING 2'-0" BEYOND CORNERS OF OPENING SHALL BE PLACED. ALL REINFORCED CELLS SHALL BE FILLED SOLIDLY WITH GROUT. REFER TO DETAILS FOR

SPECIAL REINFORCEMENT AT SUPPORTS.

7. REINFORCING BARS SHALL BE STRAIGHT EXCEPT FOR BENDS AROUND CORNERS AND WHERE BENDS OR HOOKS

ARE DETAILED ON THE PLANS.

8. REINFORCING STEEL SHALL BE LAPPED 60 BAR DIAMETERS WHERE SPLICED AND SHALL BE WIRED TOGETHER.

9. HORIZONTAL WALL REINFORCING SHALL BE EXTRA HEAVY HOHMANN & BARNARD COMPANY (LADUR TYPE) AT 1'-4" O.C. FOR 12" CMU AND STANDARD HOHMANN & BARNARD COMPANY (LADUR TYPE) AT 1'-4" O.C. FOR 8" CMU. IN LIEU OF HOHMANN & BARNARD COMPANY REINFORCEMENT THE CONTRACTOR MAY PROVIDE HORIZONTAL BOND BEAMS

LOCATED 48" O.C. VERTICALLY AND REINFORCED WITH 2-#5 CONTINUOUS BARS.

10. ALL REINFORCING SHALL BE IN PLACE PRIOR TO GROUTING. VERTICAL REINFORCING BARS SHALL BE HELD IN POSITION AT TOP, BOTTOM, AND AT INTERVALS NOT FURTHER APART THAN 192 BAR DIAMETERS BY WALL-BRAC VERTICAL STEEL POSITIONER AS MANUFACTURED BY W.C.R. FABRICATORS, OR AN EQUIVALENT POSITIONER.

11. PROVIDE CONTINUOUS CMU BOND BEAMS (8" MIN. DEPTH) REINFORCED WITH 2-#5 CONTINUOUS BARS AT TOP OF PARAPETS AND AT ROOF FRAMING ELEVATION FOR FULL LENGTH OF ALL WALLS. WHERE BOND BEAMS REQUIRE SLOPES, PROVIDE 16" DEEP BOND BEAM AND CUT TO PROVIDE AN 8" MINIMUM DEPTH. CONTINUE HORIZONTAL

REINFORCEMENT THROUGH MASONRY COLUMNS AND PILASTERS.

12. PROVIDE 2-#5 CORNER BARS (2'-6"x2'-6"), LAP WITH CONTINUOUS BARS IN ALL BOND BEAMS AT CORNERS AND WALL

INTERSECTIONS.

13. PROVIDE VERTICAL CONTROL JOINTS IN ALL MASONRY WALLS WHERE SHOWN ON ARCHITECTURAL OR STRUCTURAL DRAWINGS, AND NOT TO EXCEED 30 FEET O.C. PROVIDE MATCHING CONTROL JOINTS IN FINISH MATERIALS (i.e. BRICK, STUCCO, etc.). VERTICAL CELLS ON EACH SIDE OF CONTROL JOINTS SHALL BE REINFORCED

AND GROUTED TO MATCH THE TYPICAL WALL REINFORCEMENT.

14. AT WALL CONTROL JOINTS, CONTINUE BOND BEAM REINFORCEMENT THROUGH JOINT AND DISCONTINUE ALL OTHER

HORIZONTAL WALL REINFORCING AT JOINT.

15. ALL UNITS SHALL BE LAID WITH FULL MORTAR BEDS ON THE FACE SHELLS. ALL HEAD JOINTS SHALL BE FILLED SOLIDLY WITH MORTAR FOR A DISTANCE IN FROM THE FACE OF THE UNIT NOT LESS THAN THE THICKNESS OF THE LONGITUDINAL FACE SHELLS. UNLESS THE WALL IS TO BE POURED SOLID, END WALLS AND CROSS WEBS FORMING

CELLS TO BE FILLED SHALL BE FULLBEDDED IN MORTAR TO PREVENT LEAKAGE OF GROUT.

16. ALL DOWELS, ANCHOR BOLTS, AND HEADED STUDS SHALL BE SET IN SOLID GROUTED CELLS.

17. GROUT ALL CELLS SOLID BELOW GRADE.

LOAD BEARING STRUCTURAL MASONRY

1. POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER-OF-RECORD PRIOR TO INSTALLING POST-INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST-IN-PLACE ANCHORS. CARE SHALL BE TAKEN IN PLACING POST-INSTALLED ANCHORS TO AVOID CONFLICTS WITH EXISTING REINFORCING OR POST-TENSIONING.

2. SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE SPECIFIED BELOW, SHALL BE SUBMITTED BY THE CONTRACTOR TO THE ENGINEER-OF-RECORD ALONG WITH CALCULATIONS THAT ARE PREPARED & SEALED BY A REGISTERED PROFESSIONAL ENGINEER. THE CALCULATIONS SHALL DEMONSTRATE THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING EQUIVALENT PERFORMANCE VALUES (MINIMUM) OF THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE AND/OR STANDARD(S) AS REQUIRED BY THE BUILDING CODE.

3. POST-INSTALLED ANCHORS INCLUDE EXPANSION ANCHORS, UNDERCUT ANCHORS AND ADHESIVE ANCHORS.

ADHESIVE ANCHORS SHALL CONSIST OF A STRUCTURAL ADHESIVE AND STEEL INSERT. STEEL INSERTS SHALL BE EITHER ASTM F1554, GRADE 36 THREADED ROD OR ASTM A615, GRADE 60 REINFORCING STEEL UNLESS NOTED OTHERWISE ON THE DRAWINGS. PROVIDE, STORE AND INSTALL PRODUCTS IN STRICT CONFORMANCE WITH THE

MANUFACTURER'S RECOMMENDATIONS.

4. EXPANSION ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193. EXPANSION ANCHORS SHALL BE EITHER HILTI KWIK BOLT TZ ANCHORS OR SIMPSON STRONG-TIE STRONG-BOLT 2 ANCHORS, UNLESS NOTED OTHERWISE ON DRAWINGS. EXPANSION ANCHORS SHALL BE 3/4" DIAMETER WITH 4 3/4" EMBEDMENT UNLESS NOTED OTHERWISE

ON THE DRAWINGS.

5. EXPANSION ANCHORS FOR USE IN SOLID-GROUTED CONCRETE MASONRY SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC01. EXPANSION ANCHORS IN CMU SHALL BE EITHER HILTI KWIK

BOLT 3 ANCHORS OR SIMPSON STRONG-TIE WEDGE-ALL ANCHORS.

6. UNDERCUT ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193. UNDERCUT ANCHORS SHALL BE EITHER

HILTI HDA ANCHORS OR SIMPSON STRONG-TIE TORQ-CUT ANCHORS, UNLESS NOTED OTHERWISE ON DRAWINGS.

7. STRUCTURAL ADHESIVES FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ACI 355.4 AND ICC-ES AC308. STRUCTURAL ADHESIVES SHALL BE HITI HIT-RE 500-SD EPOXY, HILTI HIT-HY 200-A ADHESIVE, SIMPSON STRONG-TIE SET-XP ADHESIVE OR SIMPSON STRONG- TIE AT-XP ADHESIVE UNLESS NOTED OTHERWISE ON THE DRAWINGS. REFER TO DRAWINGS FOR SIZE AND EMBEDMENT REQUIREMENTS. ALL THREADED RODS USED IN EXTERIOR EXPOSURES SHALL BE GALVANIZED.

8. THE FOLLOWING PARAMETERS HAVE BEEN USED IN THE DESIGN OF ALL ADHESIVE ANCHORS UNLESS NOTED

OTHERWISE ON THE DRAWINGS:

A. MINIMUM AGE OF CONCRETE – 28 DAYS

B. CONCRETE TEMPERATURE RANGE FOR ANCHORS NOT EXPOSED TO THE ENVIRONMENT – MAXIMUM SHORT

TERM TEMPERATURE OF 104°F; MAXIMUM LONG TERM TEMPERATURE OF 75°F.

C. CONCRETE TEMPERATURE RANGE FOR ANCHORS EXPOSED TO THE ENVIRONMENT – MAXIMUM SHORT TERM

TEMPERATURE OF 150°F; MAXIMUM LONG TERM TEMPERATURE OF 110°F.

D. MOISTURE CONDITION OF CONCRETE AT THE TIME OF INSTALLATION – DRY CONCRETE

E. HOLE DRILLING AND PREPARATION – PER THE MANUFACTURER’S PRINTED INSTALLATION INSTRUCTIONS

9. STRUCTURAL ADHESIVES FOR USE IN SOLID-GROUTED CONCRETE MASONRY SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC58. STRUCTURAL ADHESIVES SHALL BE HILTI HIT-HY 70 ADHESIVE, SIMPSON STRONG-TIE SET ADHESIVE, OR SIMPSON STRONG-TIE AT ADHESIVE UNLESS NOTED OTHERWISE ON THE DRAWINGS. REFER TO DRAWINGS FOR SIZE AND EMBEDMENT REQUIREMENTS. ALL THREADED

RODS USED IN EXTERIOR EXPOSURES SHALL BE GALVANIZED.

10. ANCHOR CAPACITY IS DEPENDANT UPON THE SPACING BETWEEN ADJACENT ANCHORS AND THE PROXIMITY OF ANCHORS TO THE EDGE OF CONCRETE. INSTALL ANCHORS IN ACCORDANCE WITH THE SPACING AND EDGE

CLEARANCES INDICATED ON THE DRAWINGS.

11. PRIOR TO PLACEMENT, THE CONTRACTOR SHALL HAVE THE MANUFACTURER’S TECHNICAL REPRESENTATIVE VISIT THE SITE TO INSTRUCT THE CONSTRUCTION TEAM AND TESTING LAB ON PROPER STORAGE AND INSTALLATION TECHNIQUES. THE CONTRACTOR SHALL PROVIDE A LETTER FROM THE MANUFACTURER’S REPRESENTATIVE

STATING THAT SUCH A VISIT WAS CONDUCTED.

12. ALL EXPANSION ANCHORS SHALL BE INSPECTED BY AN INDEPENDENT TESTING LAB FOR THE FOLLOWING:

A. CORRECT LOCATION AND POSITION OF HOLE.

B. CORRECT HOLE DIAMETER

C. CORRECT EMBEDMENT DEPTH.

D. CORRECT BOLT TYPE AND FINISH.

E. CONDITION OF HOLE IN CONNECTION MATERIAL (NO BURNING OF HOLES ALLOWED).

F. SNUG TIGHT FIT.

13. ADHESIVE ANCHORS SHALL BE INSPECTED AND TESTED BY AN INDEPENDENT TESTING LAB AS FOLLOWS:

ALL ANCHORS SHALL BE INSPECTED FOR THE FOLLOWING:

A. CORRECT LOCATION AND POSITION OF HOLE.

B. CORRECT THREADED ROD OR REINFORCING BAR SIZE.

C. CORRECT THREADED ROD OR REINFORCING BAR TYPE AND FINISH.

D. CONDITION OF HOLE IN CONNECTION MATERIAL (NO BURNING OF HOLES ALLOWED).

E. SNUG TIGHT FIT.

F. CORRECT EMBEDMENT DEPTH.

G. HOLE PREPARATION (INCLUDING DRILL BIT TYPE WHERE CRITICAL TO MANUFACTURER) AND CLEANOUT PER

MANUFACTURER'S RECOMMENDATIONS.

H. ADHESIVE TYPE, EXPIRATION DATE AND METHOD OF STORAGE.

I. ADHESIVE AND ANCHOR INSTALLATION PER MANUFACTURER’S RECOMMENDATIONS.

14. THE TESTING LAB SHALL PREPARE AN INSPECTION REPORT SPECIFICALLY INDICATING DEGREE OF CONFORMANCE

IN ALL CATEGORIES LISTED ABOVE.

POST-INSTALLED ANCHOR NOTES

1. ALL SUBGRADE SHALL BE PREPARED IN STRICT CONFORMANCE TO THE GEOTECHNICAL ENGINEER’S RECOMMENDATIONS. REFER TO THE GEOTECHNICAL REPORT, SUPPLEMENTARY LETTERS AND SPECIFICATIONS

FOR ADDITIONAL INFORMATION.

THE SUBGRADE SHALL BE IMPROVED TO REDUCE THE POTENTIAL FOR SUBGRADE MOVEMENT TO LESS THAN OF ONE INCH TOTAL SETTLEMENT & 1/2 INCH OF DIFFERENTIAL SETTLEMENT BY RE-COMPACTING IN-SITU SOIL AS

APPROVED BY GEOTECH ENGINEER.

THE FOLLOWING IS A SUMMARY OF THE INFORMATION CONTAINED IN THE GEOTECHNICAL ENGINEER’S

RECOMMENDATIONS:

A. THE BUILDING EXCAVATION AREA SHALL EXTEND BEYOND THE BUILDING LINE A MINIMUM OF 5 FEET IN GENERAL. AT ALL ENTRANCES AND AT AREAS WITH SIDEWALKS/PAVING DIRECTLY ADJACENT TO THE

BUILDING.

B. WITHIN THE BUILDING AREA, EXCAVATE AND REMOVE ALL FILL MATERIAL. REFER TO THE GEOTECHNICAL REPORT FOR APPROXIMATE DEPTHS OF FILL. THE TESTING LAB SHALL DETERMINE THROUGH FIELD

OBSERVATION AND TESTING THAT ALL UNACCEPTABLE FILLS HAVE BEEN REMOVED.

C. WITHIN THE BUILDING AREA, RE-COMPACT NATIVE SOIL OR IMPORTED FILL AS REQUIRED TO PROVIDE A COMPACTED MATERIAL BENEATH BUILDING AREA. FOOTING THAT HAVE A WIDTH GREATER THAN 3FT IN

WIDTH WILL REQUIRE ADDITIONAL 2FT OF SOIL COMPACTION BENEATH FOOTING.

D. SCARIFY EXPOSED NATIVE SOILS TO A DEPTH OF 12 INCHES FOR FOOTING LESS THAN 3FT IN WIDTH AND RECOMPACT TO A MINIMUM OF 95% OF MODIFIED PROCTOR (ASTM D1557) AT A MINIMUM OF +2 PERCENTAGE POINTS ABOVE THE OPTIMUM MOISTURE CONTENT FOR THE SOIL AS DIRECTED IN THE

GEOTECHNICAL REPORT.

K. SELECT FILL SHALL CONSIST OF A SLIGHTLY SILTY SAND OR SILTY/CLAYEY SAND. ALL SELECT FILL SHALL BE

APPROVED BY THE GEOTECHNICAL ENGINEER.

L. SPREAD THE SELECT FILL IN THIN LOOSE LIFTS NOT EXCEEDING 10 TO 12 INCHES THICK FOR SLIGHTLY SILTY SAND OR LIFTS NOT EXCEEDING 6 TO 8 INCHES THICK FOR SILTY/CLAYEY SAND AND UNIFORMLY COMPACT TO A MINIMUM OF 95% OF ASTM D1557 WITHIN +2 OR –2 PERCENTAGE POINTS OF THE OPTIMUM MOISTURE

CONTENT FOR THE SOIL AS RECOMMENDED IN THE GEOTECHNICAL REPORT.

M. PLACE FIRST LIFT OF SELECT FILL WET OF OPTIMUM TO PREVENT DRYING OF THE UNDERLYING SUBGRADE.

N. PROTECT FILL TO PREVENT DESICCATION PRIOR TO PLACING A SUBSEQUENT LIFT.

2. CONTACT THE GEOTECHNICAL ENGINEER FOR ANY QUESTIONS REGARDING INTERPRETATION OR CLARIFICATION OF

THE ABOVE INFORMATION.

3. FOUNDATION AND SUBGRADE PREPARATION SHALL BE MONITORED AND TESTED BY THE SOILS ENGINEER. REFER

TO SPECIFICATIONS FOR QUALITY CONTROL REQUIREMENTS.

SUBGRADE PREPARATION

1. ALL REINFORCING STEEL SHALL BE NEW DEFORMED BILLET STEEL CONFORMING TO ASTM A615, GRADE 60.

2. DETAILING OF REINFORCEMENT SHALL BE IN ACCORDANCE WITH THE ACI DETAILING MANUAL.

3. REINFORCING BARS MAY BE SPLICED ONLY AS SHOWN ON THE DRAWINGS EXCEPT THAT REINFORCING DESIGNATED AS "CONTINUOUS" MAY BE CONTACT LAP SPLICED WITH TENSION LAP PER ACI 318 CHAPTER 25.

4. FOR CONTINUOUS GRADE BEAM REINFORCING, PER GRADE BEAM REINFORCEMENT LAP SPLICES SCHEDULED

ON S300.

5. PROVIDE CORNERS BARS OF SAME SIZE AND QUANTITY AS CONTINUOUS TOP AND BOTTOM REINFORCING OF

GRADE BEAMS AT ALL GRADE BEAM CORNERS AND INTERSECTIONS.

REINFORCING STEEL NOTES

Architect of Record:

ADG

800 SW ADAMS STREET, SUITE 101

PEORIA, IL 61602

R e vi si o n s

P - 309.672.6948

Discipline:Discipline:Discipline:

P - P - P -

Discipline:

P -

PROJECT NO.

DATE

DRAWN BY

STATUS

Discipline: Owner Consultant

QSC SERVICES, LLC

PMB #69

545 BRENT LN. PENSACOLA, FL

P - 309.231.8272

OWNER ID:

Design and Construction Administration Division

ESCAMBIA COUNTY, FL

100 E. BLOUNT ST. PENSACOLA, FL 32501

ESCAMBIA COUNTY AREA TRANSIT - FACILITY:

04 - BUS WASH

10 CLARINDA LN

PENSACOLA, FL 32505 S001GENERAL NOTES

KEDbluestone

707 NE JEFFERSON AVE,

PEORIA, IL 61602

RLG CONSULTING ENGINEERS

12001 N CENTRAL EXPY, STE 300

DALLAS, TX 75243

RLG CONSULTING ENGINEERS

12001 N CENTRAL, STE 300

DALLAS, TX 75243

214.739.8100 214.739.8100 515.259.5957

HODGSON DOUGLAS LANDSCAPE ARCHITECTS

12001 N CENTRAL EXPY, SUITE 1170

DALLAS, TX 75243

214.749.0333

BID PACKAGE #2 - NOT FOR CONSTRUCTION

10/22/2026

RLG

A D

D

.1

.1

ADD

ADD

T/CONC EL

SEE PLAN

CL OF CMU AND FTG

PAVING - REF CIVIL

12" CMU WALL REINF -

SEE PLAN

GROUT ALL CELLS

SOLID BELOW GRADE

DOWELS TO MATCH VERT

BAR SIZE AND SPACING W/

STD ACI HOOK

EQ EQ

4'-0" @ SIM

5'-0"

T/FTG EL

#5 @ 12" OC CONT

#5 @ 12" OC IN

TRANSVERSE DIR

1/2" EXPANSION JOINT

W/ BACKER ROD AND

SEALANT

PREPARED SOIL PER

GEOTECH REPORT

CONC SLAB-ON-GRADE

REINF -SEE PLAN & GEN

NOTES

VAPOR BARRIER -

SEE GEN NOTES

T/CONC EL

SEE PLAN

℄ OF CMU AND FTG

PAVING - REF CIVIL

GROUT ALL CELLS

SOLID BELOW GRADE

T/FTG EL

1/2" EXPANSION JOINT

W/ BACKER ROD AND

SEALANT

#4 X 18" SMOOTH

DWLS @ 18" OC -

GREASE ON END

CONC SLAB-ON-GRADE

REINF - SEE PLAN AND

GEN NOTES

#4 DWLS @ 16" OC W/

1- #5 CONT

24"

CONT FTG REINF -

SEE 01/S400

4'-0" @ SIM

5'-0"

EQ EQ

24"

T/CONC EL

SEE PLAN

℄ OF CMU AND FTG

12" CMU WALL REINF -

SEE PLAN

GROUT ALL CELLS

SOLID BELOW GRADE

DOWELS TO MATCH VERT

BAR SIZE AND SPACING W/

STD ACI HOOK

EQ EQ

4'-0" @ SIM

5'-0"

T/FTG EL

CONT FTG REINF -

SEE 01/S400

1/2" EXPANSION JOINT

W/ BACKER ROD AND

SEALANT

CONC SLAB REINF -SEE

PLAN AND GEN NOTES

VAPOR BARRIER -

SEE GEN NOTES

T/CONC EL

SEE PLAN

7'-2"

T/FTG EL

94'-0"

#5 @ 8" OC CONT

TOP AND BOT

#5 @ 8" OC IN TRANSVERSE

DIRECTION (TOP & BOT)

#4 CONT (TYP)

1 1/4" X 3/16" GALV STEEL

GRATING SYSTEM

CONT GALVANIZED BEARING

L2X2X1/4 W/ 1/2" DIA X 5" HS

@ 12" OC

1'-6" 8" w/ BUS WASH MFR

2'-10" GC TO VERIFY 8" 1'-6"

1/2" X 5" X5"X0'-6" (GALV)

EMBED PL w/ 1- 3/4" DIA

HS X0'-6" @ EA HSS

HSS4x4x1/4 @ 6'-0"

#4 DWL X 2'-0" @ 12" OC

℄ OF TRENCH

DRAIN

#5 VERT @ 12" OC

(CENTERED) w/ #5

CONT @ 10" OC

2X4 CONT KEYWAY w/

WATERSTOP -TYP

DRAIN TILE - REF

MEP DRAWINGS

VAPOR BARRIER - REF

PROJECT SPECS

CONC SLAB-ON-GRADE -

SEE PLAN & GEN NOTES

DOWELS TO MATCH

VERT BARS AND

SPACING

3/16

(GC TO

VERIFY

W/ MFR)

NOTE:

GC SHALL NOT BACKFILL BEHIND PIT

WALL UNTIL HSS BEAMS ARE INSTALLED.

REFER TO GEOTECH REPORT FOR

BACKFILLING REQUIREMENTS.

8" 8"

TOUCH UP W/

GALVANIC PAINT

ADD

T/CONC EL

SEE PLAN

T/FTG EL

94'-0"

℄ OF TRENCH

DRAIN

PVC SLEEVE

PER BUS WASH

MFR - TYP

S L E

E V

E E

L E

V A

T

IO

N

S E

E M

F R

F O

R

CONC PIT WALL

BEYOND

CONC PIT WALL

BEYOND

6" WIDE CONC WALL

REINF w/ #5 VERT @ 12" OC (CENTERED) w/ #5

@ 10" OC CONT

SEE 04/S400 FOR

ADDITIONAL INFORMATION

NOT SHOWN FOR CLARITY

DOWELS TO MATCH

VERT BARS AND

SPACING

(GC TO

VERIFY

W/ MFR)

SLEEVE LOCATION

SEE MFR FOR

SLEEVE LOCATION

SEE MFR FOR

ADD

T/CONC EL

SEE PLAN

CL OF CMU AND FTG

PAVING - REF CIVIL

12" CMU WALL REINF W/

#5 @ 32" OC VERT

2- #5 @ 48 HORIZ -

GROUT WALL SOLID

GROUT ALL CELLS

SOLID BELOW GRADE

DOWELS TO MATCH VERT

BAR SIZE AND SPACING W/

STD ACI HOOK

EQ EQ

4'-0"

T/FTG EL

#5 @ 12" OC CONT

TOP AND BOT

#5 @ 12" OC IN

TRANSVERSE

DIRECTION

1/2" EXPANSION JOINT

W/ BACKER ROD AND

SEALANT

PAVING - REF CIVIL

T/WALL EL

106'-0" (MAX)

MASONRY CAP -

REF ARCH

T/CONC EL

SEE PLAN

12" CMU WALL REINF -

SEE PLAN

T/FTG EL

CONC SLAB-ON-GRADE

REINF -SEE PLAN & GEN

NOTES

SEE 01/S400 FOR

ADDITIONAL INFORMATION

NOT SHOWN FOR CLARITY

LINE OF CONT FTG

BEYOND - SEE 01/S400

CANTILEVERED 12" CMU

WALL REINF - SEE 06/S400

CONT FTG REINF -

SEE 06/S400

1" EJ

12" CMU WALL REINF -

SEE PLAN NOTE

COILING DOOR GUIDE

RAIL AND CONNX PER

MFR

COILING DOOR SYSTEM -

REF ARCH

T/CONC EL

SEE PLAN

℄ OF CMU AND FTG

PAVING - REF CIVIL

GROUT ALL CELLS

SOLID BELOW GRADE

T/FTG EL

1/2" EXPANSION JOINT

W/ BACKER ROD AND

SEALANT

#4 X 18" SMOOTH

DWLS @ 18" OC -

GREASE ON END

CONC SLAB-ON-GRADE

REINF - SEE PLAN AND

GEN NOTES

#4 DWLS @ 16" OC W/

1- #5 CONT

24"

CONT FTG REINF -

SEE 01/S400

5'-0"

EQ EQ

24"

REF ARCH

COILING DOOR

SYSTEM - REF ARCH

/2

S

T E

P

1/2" SLOPE

Architect of Record:

ADG

800 SW ADAMS STREET, SUITE 101

PEORIA, IL 61602

R e vi si o n s

P - 309.672.6948

Discipline:Discipline:Discipline:

P - P - P -

Discipline:

P -

PROJECT NO.

DATE

DRAWN BY

STATUS

Discipline: Owner Consultant

QSC SERVICES, LLC

PMB #69

545 BRENT LN. PENSACOLA, FL

P - 309.231.8272

OWNER ID:

Design and Construction Administration Division

ESCAMBIA COUNTY, FL

100 E. BLOUNT ST. PENSACOLA, FL 32501

ESCAMBIA COUNTY AREA TRANSIT - FACILITY:

04 - BUS WASH

10 CLARINDA LN

PENSACOLA, FL 32505 S400FOUNDATION DETAILS

KEDbluestone

707 NE JEFFERSON AVE,

PEORIA, IL 61602

RLG CONSULTING ENGINEERS

12001 N CENTRAL EXPY, STE 300

DALLAS, TX 75243

RLG CONSULTING ENGINEERS

12001 N CENTRAL, STE 300

DALLAS, TX 75243

214.739.8100 214.739.8100 515.259.5957

HODGSON DOUGLAS LANDSCAPE ARCHITECTS

12001 N CENTRAL EXPY, SUITE 1170

DALLAS, TX 75243

214.749.0333

BID PACKAGE #2 - NOT FOR CONSTRUCTION

10/22/2026

RLG

A D

D

.1

.1

T/ WALL

REF ARCH

2" CMU SOAP

T/ PLANK

SEE PLAN

GROUT CMU CELLS

THAT HAVE DOWEL

FROM PRECAST PLANK

8X12 BOND BEAM W/

(2) - #5 CONT

12" CMU WALL

REINF - SEE PLAN

PROVIDE BEARING PAD OR

DRY PACK AS REQ'D FOR

CAMBER

4" MIN

PRECAST PLANK PER

PRECAST ENGR

L8x4x7/16 (LLV - GALV) CONT w/ 2" VERT SLOTTED HOLE w/ 5/8"

DIA F1554 GR 36 THREADED

ROD @ 16" OC USING HILTI

HY-270 (6" EMBED)

EMBED PL (GALV) @ 48" OC

MAX BY PRECAST MFR

DIAPHRAGM SHEAR = 0.150 KLF

(LRFD)

M

IN4

2"3/16

GC TO TOUCH UP WELD

WITH GALVANIC PAINT

GROUT WALL SOLID

ABOVE THE CONC

PLANK

METAL CAP -

REF ARCH

T/ WALL

REF ARCH

T/ PLANK

SEE PLAN

GROUT CMU CELLS

THAT HAVE DOWEL

FROM PRECAST PLANK

8X12 BOND BEAM W/

(2) - #5 CONT

12" CMU WALL

REINF - SEE PLAN

PRECAST PLANK PER

PRECAST ENGR

L8x4x7/16 (LLV - GALV) CONT w/ 2" VERT SLOTTED HOLE w/ 5/8"

DIA F1554 GR 36 THREADED

ROD @ 16" OC USING HILTI

HY-270 (6" EMBED)

2"3/16

GC TO TOUCH UP WELD

WITH GALVANIC PAINT

PROVIDE BEARING PAD OR

DRY PACK AS REQ'D FOR

CAMBER

EMBED PL (GALV) @ 48" OC

MAX BY PRECAST MFR

DIAPHRAGM SHEAR = 0.150 KLF

(LRFD)

GROUT WALL SOLID

ABOVE THE CONC

PLANK

4" MIN

METAL CAP -

REF ARCH

2" CMU SOAP

GUTTER SYSTEM & CONNX

PER GUTTER MFR

T/ PLANK

SEE PLAN

8X12 BOND BEAM W/

(2) - #5 CONT

12" CMU WALL

REINF - SEE PLAN

PRECAST PLANK PER

PRECAST ENGR

ROOFING - REF ARCH

ANGLE CONNECTION, SEE

01/S500 FOR DETAILS

EMBED PL (GALV) @ 48" OC

MAX BY PRECAST MFR

DIAPHRAGM SHEAR = 0.150 KLF

(LRFD)

2"3/16

2" CMU SOAP

#4 DWL X 24" @ KEYWAY

(2) - #5 CONT

HOLLOW CORE PLANK

IS ROTATED AT SIM.

T/ WALL

REF ARCH

2" CMU SOAP

T/ PLANK

SEE PLAN

GROUT CMU CELLS

THAT HAVE DOWEL

FROM PRECAST PLANK

8X12 BOND BEAM W/

(2) - #5 CONT

12" CMU WALL

REINF - SEE PLAN

AND PLAN NOTE

PRECAST PLANK PER

PRECAST ENGR

PROVIDE BEARING PAD OR

DRY PACK AS REQD FOR

CAMBER

4" MIN

12X32 CONT BOND

BEAM w/ 3-#5 TOP &

BOT

COIL DOOR SYSTEM

PER COIL DOOR MFR

EMBED PL @ 24" OC MAX BY

PRECAST MFR DIAPHRAGM

SHEAR = 1 KLF (LRFD)

L8x4x7/16 (LLV - GALV) CONT w/ 2" VERT SLOTTED HOLE w/ 5/8"

DIA F1554 GR 36 THREADED

ROD @ 16" OC USING HILTI

HY-270 (6" EMBED)

GROUT WALL SOLID

ABOVE THE CONC

PLANK

2"3/16

METAL CAP -

REF ARCH

COIL DOOR CONNX PER

COIL DOOR MFR

T/ PLANK

SEE PLAN

T/ PLANK

SEE PLAN

GUTTER SYSTEM & CONNX

PER GUTTER MFR

ROOFING REF ARCH

PRECAST PLANK PER

PRECAST ENGR

GROUT CMU CELLS

THAT HAVE DOWEL

FROM PRECAST PLANK

8X12 BOND BEAM W/

(2) - #5 CONT

12" CMU WALL

REINF - SEE PLAN

EMBED PL & ANGLE

CONNX - SEE 02/S500 FOR

DETAILS (TYP)

EMBED PL & ANGLE

CONNX - SEE 02/S500 FOR

DETAILS (TYP)

2" CMU SOAP

(2) - #5 CONT

#4 DWL X 24" @ KEYWAY

2" CMU SOAP

T/ PLANK

SEE PLAN

8X8 BOND BEAM W/

(2) - #5 CONT

8" CMU WALL REINF -

SEE PLAN

PROVIDE BEARING PAD OR

DRY PACK AS REQ'D FOR

CAMBER

PRECAST PLANK PER

PRECAST ENGR

PROVIDE BEARING PAD OR

DRY PACK AS REQD FOR

CAMBER

L8x4x7/16 (LLV - GALV) CONT w/ 2" VERT SLOTTED HOLE w/ 5/8"

DIA F1554 GR 36 THREADED

ROD @ 16" OC USING HILTI

HY-270 (6" EMBED) STAGGERED

CELLS

EMBED PL (GALV) @ 24" OC

MAX BY OTHERS DIAPHRAGM

SHEAR = 2.7 KLF (LRFD)

STAGGER EMBED PLATES

M

IN4

33/16

EA EMBED

GC TO TOUCH UP WELD

WITH GALVANIC PAINT

GROUT ALL CELLS

w/ (2) - #5 CONT

T/ WALL

REF ARCH

2" CMU SOAP

T/ PLANK

SEE PLAN

GROUT CMU CELLS

THAT HAVE DOWEL

FROM PRECAST PLANK

8X12 BOND BEAM W/

(2) - #5 CONT

12" CMU WALL

REINF - SEE PLAN

4" MIN

PRECAST PLANK PER

PRECAST ENGR

PROVIDE BEARING PAD OR

DRY PACK AS REQD FOR

CAMBER

L8x4x7/16 (LLV - GALV) CONT w/ 2" VERT SLOTTED HOLE w/ 5/8"

DIA F1554 GR 36 THREADED

ROD @ 16" OC USING HILTI

HY-270 (6" EMBED)

EMBED PL (GALV) @ 24" OC

MAX BY OTHERS

DIAPHRAGM SHEAR = 1 KLF

(LRFD)

M

IN4

GC TO TOUCH UP WELD

WITH GALVANIC PAINT

METAL CAP -

REF ARCH

T/ PLANK

SEE PLAN

EMBED PL PER

PRECAST ENGINEER

(4'-0" MAX SPACING)

8" HOLLOW CORE PLANK

PER PRECAST ENGR

GUARDRAIL SYSTEM -

REF ARCH (4'-0" MAX

SPACING)

GC TO COORDINATE GUARDRAIL

POST LOCATIONS FROM ARCH

DRAWINGS W/ PLANK DESIGNER

PLANK DESIGNER TO

DESIGN FOR ADDL LOAD:

H = 200 LB

M = 700 LB-FT

H

M

Architect of Record:

ADG

800 SW ADAMS STREET, SUITE 101

PEORIA, IL 61602

R e vi si o n s

P - 309.672.6948

Discipline:Discipline:Discipline:

P - P - P -

Discipline:

P -

PROJECT NO.

DATE

DRAWN BY

STATUS

Discipline: Owner Consultant

QSC SERVICES, LLC

PMB #69

545 BRENT LN. PENSACOLA, FL

P - 309.231.8272

OWNER ID:

Design and Construction Administration Division

ESCAMBIA COUNTY, FL

100 E. BLOUNT ST. PENSACOLA, FL 32501

ESCAMBIA COUNTY AREA TRANSIT - FACILITY:

04 - BUS WASH

10 CLARINDA LN

PENSACOLA, FL 32505 S500FRAMING DETAILS

KEDbluestone

707 NE JEFFERSON AVE,

PEORIA, IL 61602

RLG CONSULTING ENGINEERS

12001 N CENTRAL EXPY, STE 300

DALLAS, TX 75243

RLG CONSULTING ENGINEERS

12001 N CENTRAL, STE 300

DALLAS, TX 75243

214.739.8100 214.739.8100 515.259.5957

HODGSON DOUGLAS LANDSCAPE ARCHITECTS

12001 N CENTRAL EXPY, SUITE 1170

DALLAS, TX 75243

214.749.0333

BID PACKAGE #2 - NOT FOR CONSTRUCTION

10/22/2026

RLG

A D

D

.1

.1

ADD

ADD

ADD

ADD

ABC

WIDTH OF THE BUILDING FROM EDGE OF FDN TO EDGE OF FDN

32' - 8"

FA

CE

O F

FD

N

T O

F

AC

E O

F

FD

N

LE

N

GH

T O

F

TH

E

BU

IL

DI

N G

FR

O

M E

DG

E

O F

FD

N

T O

E

DG

E O

F

FD

N

FACE OF FDN TO FACE OF FDN

22' - 0"

FA

CE

O F

FD

N

T O

F

AC

E O

F

FD

N

FACE OF FDN TO FACE OF FDN

11' - 8''

FA

CE

O F F

DN

T

O

FA

CE

O

F F

DN

FA

CE

O F

FD

N

T O

F

AC

E O

F

FD

N

FA

CE

O F

FD

N

T O

F

AC

E O

F

FD

N

FACE OF FDN TO FACE OF FDN

23' - 4"

2' - 10"

BASE POINT COORDINATE:

N 538687' 98" E 1106574' 91"

SURVEY POINT COORDINATE:

N 538739' 66" E 1106572' 23"

AB

C

22' - 0"10' - 8"

32' - 8"

10' - 8"

FR

O

M G

RI

D

LI

N

E

TO

F .O

. T

HE

R O

O F

0'

/8

LE

N

GT

H

O F

TH

E

RO

O

F

/4

FR

O M

G

RI

D

LI

N E

TO

F

.O . T

HE

R

O O

F 0'

/8

FR

O

M G

RI

D

LI

N

E

TO

F .O

. T

HE

R O

O F

0'

/8

/8

/8

0'

/8

LE

N

GT

H

O F

TH

E

RO

O

F

/4

RO

O

F

TY

PE

: R

-3

RO

O

F

TY

PE

: R

-3

PREFINISHED METAL GUTTER

AND DOWNSPOUTS BY PEMB, TYP.

VERIFY QUANTITY AND SIZE.

PREFINISHED METAL GUTTER

AND DOWNSPOUTS BY PEMB, TYP.

VERIFY QUANTITY AND SIZE.

PREFINISHED METAL GUTTER

AND DOWNSPOUTS BY PEMB, TYP.

VERIFY QUANTITY AND SIZE.

RO

OF

T

YP

E:

R

PREFINISHED METAL GUTTER

AND DOWNSPOUTS BY PEMB, TYP.

VERIFY QUANTITY AND SIZE.

W

ID

TH

O

F T

HE

R

OO

F

9'

3/

4"

21' - 4 3/4"

0' - 11 5/8"

0'

0"

FIXED STEEL ROOF ACCESS LADDER.

PROVIDE LOCKABLE SECURITY GATE AT

LADDER BASE. EXTEND LADDER SIDE RAILS

OR SAFETY POSTS 42" MIN. ABOVE ROOF.

INSTALL IN ACCORDANCE WITH OSHA 29

CFR 1910.23. PROVIDE BILCO LADDERUP OR

APPROVED EQUAL SAFETY POST AT ROOF

ACCESS POINT.

PROVIDE PERMANENT GUARDRAIL

SYSTEM AT CONDENSING UNIT SERVICE

AREA WHERE REQUIRED FOR FALL

PROTECTION. GUARDRAIL SHALL COMPLY

WITH APPLICABLE OSHA REQUIREMENTS.

SEE STRUCTURAL DRAWINGS FOR DESIGN

AND DETAILS.

10' - 0"

8' - 3"

5'

5/

8"

ABC

FA

CE

O F

FD

N

T O

F

AC

E O

F

FD

N

FACE OF FDN TO FACE OF FDN

32' - 8"

FA

CE

O F

FD

N

T O

F

AC

E O

F

FD

N

FA

CE

O

F

FD

N T

O F

AC

E

O F

FD

N

FA

CE

O F

FD

N

T O

F

AC

E O

F

FD

N

FACE OF FDN TO FACE OF FDN

22' - 0"

FACE OF FDN TO FACE OF FDN

10' - 8"

EQUIPMENT

ROOM

ADA

RESTROOM

FARE

PROCESING

FARE

ENTRANCE

WASH

BAY

EDGE TO EDGE OF FDN

23' - 4"

ED

GE

T O

ED

GE

O F F

DN

2'

1/

4" 6'

0"

2'

5/

8"

17' - 5 3/8"

17' - 5 3/8"

VACUUM28

112.5°

112.5°

FA

CE

O F

FD

N

T O

F

AC

E O

F

FD

N

M.O.

3' - 4"2' - 0" 4' - 0"

M.O 14' - 0"

4' - 0"M.O 14' - 0"

M .O

3'

4"

6'

4"

3'

4"

3'

4"

2' - 8"

1'

5/

8"

/4

/8

4X5 DOWNSPOUT, CONNECT TO

UNDERGROUND STORM SYSTEM.

REFER TO CIVIL DWGS

4X5 DOWNSPOUT, CONNECT

TO UNDERGROUND STORM

SYSTEM. REFER TO CIVIL DWGS

4X5 DOWNSPOUT, CONNECT

TO UNDERGROUND STORM

SYSTEM. REFER TO CIVIL DWGS

21' - 4 3/4"

7'

4"

DUMPSTER WING WALLS:

TOP COURSE: BULLNOSE

CMU, NO EXPOSED CORES

WT1

WT2

R1

R1

WT2

R1

WT2

WT3WT3

WT3

WT2

WT1

WT1

R1

WT3WT2

WT2

WT3

R1

WT1

HOLLOW CORE

CONCRETE PLANK

R-35 AVG. INSULATION WITH

TAPERED INSULATION @ 1/4'':12''

ROOF MEMBRANE

11 5/8" GROUND FACE CMU.

PROVIDE FULL BED MORTAR JOINTS AND

TOOL ALL JOINTS TO A CONCAVE PROFILE

(WT1: EB1, MT1 - WT2: EP2, MT1)

INTERIOREXTERIOR

PROVIDE INTEGRAL WATER-REPELLENT

ADMIXTURE IN ALL EXPOSED GROUND-FACE

CMU AND MORTAR AS PART OF A SINGLE-

SOURCE MASONRY WATER-REPELLENT

SYSTEM. AFTER MASONRY HAS CURED AND

BEEN CLEANED, APPLY MANUFACTURER'S

RECOMMENDED CLEAR BREATHABLE

SILANE/SILOXANE PENETRATING WATER

REPELLENT TO THE EXTERIOR FACE OF THE

WALL

WT1 - DARK

WT2 - LIGHT

EB1 ECHELON MASONRY - STANDARD MASONRY - TRENWYTH HIGH POLISH

GROUND FACE BRICK - SIZE: 8" X 12" X 16" - COLOR: 5108 (DARK)

EB2 ECHELON MASONRY - STANDARD MASONRY - TRENWYTH HIGH POLISH

GROUND FACE BRICK - SIZE: 8" X 12" X 16" - COLOR: 5301 (LIGHT)

EB3 ECHELON MASONRY - STANDARD MASONRY - TRENWYTH HIGH POLISH

GROUND FACE BRICK - SIZE: 8" X 8" X 16" - COLOR: 5301 (LIGHT)

EB4 ECHELON MASONRY - STANDARD MASONRY - TRENWYTH HIGH POLISH

GROUND FACE BRICK - SIZE: 8" X 8" X 16" - COLOR: 5301 (DARK)

MP1 MBCI - CONCEALED FASTENING SYSTEM - FW-120-2 PANEL, 24 GAUGE, SMOOTH -

COLOR: BROWNSTONE

MP2 ARMSTRONG WALL & ROOF SYSTEMS - PBU PANEL - COLOR: POLAR WHITE

MT1 SOLOMON COLORS, INC., CONCENTRATED MORTAR - COLOR: 22X TAN

EXTERIOR FINISH SCHEDULE

WT1

WT1

WT2

WT2

WT3

WT3 WT2

WT2

FOR WALL TYPES - SEE

DETAILS 5, 6, & 7 ON

THIS SHEET

FINISHED GRADE - SEE

CIVIL

CONTINUOUS FOOTING -

SEE STRUC

M

IN

0'

1"

ALIGN CMU WITH

OUTSIDE FACE OF

FOUNDATION WALL

INTERIOR SLAB ON

GRADE - SEE STRUC

PREFORMED JOINT

FILLER W/ SELF LEVELING

POLYURETHANE SEALANT

ON TOP OF PJF

14"x4"x48" PRECAST

CAST STONE COPING

UNIT

11 5/8" GROUND FACE CMU (EB3, MT1)

DRIP EDGE ON BOTH

SIDES

1' - 2"

0'

4"

1" OVERHANG

SEE

ELEVATIONS

WT3 - LIGHT

0'

1"

Architect of Record:

ADG

800 SW ADAMS STREET, SUITE 101

PEORIA, IL 61602

Re vi sio ns

P - 309.672.6948

Discipline:Discipline:Discipline:

P - P - P -

Discipline:

P -

PROJECT NO.

DATE

DRAWN BY

STATUS

Discipline:Discipline: Owner Consultant

QSC SERVICES, LLC

PMB #69

545 BRENT LN. PENSACOLA, FL

P - 309.231.8272

OWNER ID:

Design and Construction Administration Division

ESCAMBIA COUNTY, FL

100 E. BLOUNT ST. PENSACOLA, FL 32501

ESCAMBIA COUNTY AREA TRANSIT - FACILITY:

04 - BUS WASH

10 CLARINDA LN

PENSACOLA, FL 32505 X001LAYOUT PLAN, 3D VIEWS AND WALL / ROOF

ASSEMBLIES

KEDbluestone

707 NE JEFFERSON AVE,

PEORIA, IL 61602

RLG CONSULTING ENGINEERS

12001 N CENTRAL, EXPY #300

DALLAS, TX 75243

RLG CONSULTING ENGINEERS

12001 N CENTRAL,

DALLAS, TX 75243

214.739.8100 214.739.8100 515.259.5957

HODGSON DOUGLAS LANDSCAPE ARCHITECTS

12001 N. CENTRAL EXPRESSWAY, SUITE 1170

DALLAS, TX 75243

214.749.0333

BID PACKAGE #2 - NOT FOR CONSTRUCTION

11/12/2026

ADG

5 3D VIEW, ROOF AND EXTERIOR WALL ASSEMBLIES

1/8" = 1'-0"

4 ROOF PLAN

6 3D VIEW, ROOF AND EXTERIOR WALL ASSEMBLIES

1" = 1'-0"

WT1 - GFB12 - DARKWT1 - GFB12 - DARK

R1

1/8" = 1'-0"

1 FIRST FLOOR LAYOUT PLAN

1/8" = 1'-0"

2 FIRST FLOOR DIMENSIONS AND WALL TYPE PLAN

N N N

AD

D

.1 0.

WT1 - DARK

WT2 - LIGHT

7 3D VIEW, ROOF AND EXTERIOR WALL ASSEMBLIES

1 1/2" = 1'-0"

3 TYP FOUNDATION DETAIL

WT3

PROVIDE UNDER SLAB AT VAPOR BARRIER

EXTERIOR WALL TYPE (WT) ASSEMBLIES

FIRST FLOOR

0' - 0"

T.O. EQUIPMENT ROOM

13' - 4"

1 2

B.O. WASH BAY

20' - 0"

B.O. EQUIPMENT ROOM

12' - 8"

T.O. WASH BAY

22' - 8"

3 4

PREFINISHED 8'' x 8'' METAL GUTTERS AND 4'' x

5'' DOWNSPOUTS.

PREFINISHED 8'' x 8'' METAL GUTTERS AND 4'' x

5'' DOWNSPOUTS.

PREFINISHED 8'' x 8''

METAL GUTTERS AND

4'' x 5'' DOWNSPOUTS.

102A103 101A

7'

4" R

.O

7'

4" R

.O

6' - 4" R.O.

7'

4" R

.O

3' - 4" R.O.

3' - 4" R.O.

A B C

PREFINISHED 8'' x 8'' METAL GUTTERS AND 4'' x 5'' DOWNSPOUTS.

" R

.O

101C

3' - 4" R.O.

7'

4" R

.O

PREFINISHED 8'' x 8'' METAL GUTTERS AND 4'' x

5'' DOWNSPOUTS.

FIRST FLOOR

0' - 0"

T.O. EQUIPMENT ROOM

13' - 4"

B.O. WASH BAY

20' - 0"

T.O. WASH BAY

22' - 8"

PAY TERMINAL - 26"W x 30"H OPENING

PROVIDE WOOD SHIMS AND .090" STAINLESS STEEL FLASHING ON ALL FOURS

SIDES OF THE OPENING. PROVIDE STAINLESS STEEL FACADE FROM VAULT

MANUFACTURER. SEAL ASSEMBLY AND FLASHING WEATHERTIGHT. PROVIDE

BOTTOM-HINGED SECURITY DOOR WITH STAPLE PLATE HASP LOCK AT TOP OF

DOOR. PROVIDE HARDWOOD SILL INSIDE STEEL FACADE TO PREVENT DAMAGE TO

CASHBOXES, PRE-DRILLED AND COUNTERSUNK ON BOTH SIDES FOR 10-32

FLATHEAD CAP SCREWS. PROVIDE AN L-ANGLE 2"X2"X32" PLACED AGAINST THE

FRONT LEGS OF THE VAULT AND BOLT TO THE FLOOR TO ENSURE THE VAULT

REMAINS TIGHT AGAINST THE WALL; L-ANGLE WITH FOUR 1/2" DIAMETER HOLES,

EQUALLY SPACED. REFER TO VAULT MANUFACTURER'S STANDARD INSTALLATION

RECOMMENDATIONS FOR MORE INFORMATION.

B.

O

. O F

O

PE

N

IN

G 2'

/2

" T O

2' - 2"

2'

6"

ABC

PREFINISHED 8'' x 8'' METAL GUTTERS AND 4'' x

5'' DOWNSPOUTS.

PREFINISHED 8'' x 8''

METAL GUTTERS AND 4''

x 5'' DOWNSPOUTS.

" R

.O

101B

FIRST FLOOR

0' - 0"

T.O. EQUIPMENT ROOM

13' - 4"

B.O. EQUIPMENT ROOM

12' - 8"

PREFINISHED 8'' x 8'' METAL GUTTERS AND 4'' x

5'' DOWNSPOUTS.

DU

M

PS

TE

R W

AL

L

HE

IG

HT

6'

0"

DUMPSTER WING WALLS

WT3: 14"x4"x48" PRECAST

CAST STONE COPING UNIT.

SEE WALL TYPE ON X001.

DUMPSTER WING WALLS

WT3: 14"x4"x48" PRECAST

CAST STONE COPING UNIT.

SEE WALL TYPE ON X001.

RO

U

GH

O

PE

N

IN

G

8'

0"

ROUGH OPENING

6' - 0"

FIRST FLOOR

0' - 0"

T.O. EQUIPMENT ROOM

13' - 4"B.O. EQUIPMENT ROOM

12' - 8"

GENERAL ELEVATION NOTES

SEE X001 FOR EXTERIOR WALL ASSEMBLIES & LAYOUT

SEE SHEET A900 FOR DOOR SCHEDULE, ELEVATIONS & DETAILS

SEE SHEET X800 FOR DETAILS

Architect of Record:

ADG

800 SW ADAMS STREET, SUITE 101

PEORIA, IL 61602

Re vi sio ns

P - 309.672.6948

PROJECT NO.

DATE

DRAWN BY

STATUS

Discipline:Discipline: Owner Consultant

QSC SERVICES, LLC

PMB #69

545 BRENT LN. PENSACOLA, FL

P - 309.231.8272

OWNER ID:

Design and Construction Administration Division

ESCAMBIA COUNTY, FL

100 E. BLOUNT ST. PENSACOLA, FL 32501

ESCAMBIA COUNTY AREA TRANSIT - FACILITY:

04 - BUS WASH

10 CLARINDA LN

PENSACOLA, FL 32505 X300EXTERIOR ELEVATIONS

BID PACKAGE #2 - NOT FOR CONSTRUCTION

11/12/2026 Author

1/4" = 1'-0"

4 WASH BLDG WEST ELEVATION

1/4" = 1'-0"

1 WASH BLDG NORTH ELEVATION

1/4" = 1'-0"

2 WASH BLDG EAST ELEVATION

1/4" = 1'-0"

3 WASH BLDG SOUTH ELEVATION

1/4" = 1'-0"

8 VACUUM/DUMPSTER WEST ELEVATION

1/4" = 1'-0"

7 VACUUM/DUMPSTER SOUTH ELEVATION

1/4" = 1'-0"

6 VACUUM/DUMPSTER EAST ELEVATION

1/4" = 1'-0"

5 VACUUM/DUMPSTER NORTH ELEVATION

AD

D

.1

0.

NORTHWEST AERIAL VIEW SOUTHEAST AERIAL VIEW

ADD

ADD

ABC

WASH

BAY

EQUIPMENT

ROOM

ADA

RESTROOM

FARE

PROCESING

FARE

ENTRANCE PAY TERMINAL - SEE

ELEVATION FOR OPENING

DIMENSIONS

DOWNSPOUT

DOWNSPOUT

BOLLARDBOLLARD

BOLLARD

BOLLARD

BOLLARD

BOLLARD

VACUUM

DUMPSTER B

DUMPSTER A

DOWNSPOUT

DOWNSPOUT

101C

102B

101B

A110

101A

23' - 4"

102A

BASIS OF DESIGN SELECTION FOR

FINISHES AND EQUIPMENT, OR

APPROVED EQUAL.

GENERAL SHEET NOTES

SEE G000 FOR CODE PLANS & GENERAL INFORMATION

SEE 'X' SHEETS FOR EXTERIOR ASSEMBLIES & ADDITIONAL INFORMATION

WALL LEGEND

NEW CONSTRUCTION WALL AND PARTITION

NEW CONSTRUCTION DOOR AND FRAME

ABC

EQUIPMENT

ROOM

ADA

RESTROOM

FARE

PROCESING

FARE

ENTRANCE

WASH

BAY

23' - 4"

9'

7/

8"

/8

8'

3/

4"

EQ

EQ

EQ2' - 10"EQ

--CMU12--

-- B-

--CMU8--

-- B-

--CMU8--

-- B-

--CMU8--

-- B-

--CMU8--

-- B-

--CMU12--

-- B-

5'

1/

2"

/8

7'

3/ 4"

1'

5/

8"

/2

11' - 7 5/8" 21' - 0 3/8"

NOTE: STANDARD PARTITION TYPE

--CMU8--

-- B-

--CMU12--

-- B-

PARTITION LEGEND

CMU

CMU CONCRETE MASONRY UNIT

PARTITION ABBREVIATIONS

TYPE MARK

X-M358-X

SHEATHING LAYER 02

SIZE OF CORE MATERIAL

SHEATHING LAYER 01

X-M358-X

INS UL FR P

TYPE MARK

WALL TYPE NOTES

FIRE RATING (IN HRS)

UL CODE

INSULATION

CORE MATERIAL

PARTITION TAG

CORE MATERIAL

- NO MATERIAL

SHEATHING MATERIAL

P

B

PARTITION WITH CORE MATERIAL TO DECK

ABOVE, SHEATHING TO 6" ABOVE CEILING

BARRIER WITH CORE MATERIAL AND SHEATHING

TO…

This is the start of the file's text. The full file is on GovTribe.