ECAT_BP2_DRAWING_SET_-_03_TRANSFER_CENTER_Rev_1__26-11-13.pdf
PDF 9 MB Posted
- Solicitation number
- PD 26-27.004
- Issued by
- Escambia County, Florida
About this file
ECAT Transfer Center Drawing Set Summary
This document is a comprehensive structural drawing set for Bid Package #2 of the Escambia County Area Transit (ECAT) Facility's Passenger Terminal Transfer Center, prepared by design firm KED bluestone and structural engineers RLG Consulting Engineers. The project, located at 41 Clarinda Lane in Pensacola, Florida, involves construction of a transfer center building with associated canopy structures. The drawing set includes general structural notes, roof framing plans, foundation details, wall and roof assembly specifications, exterior elevations, interior layouts, door schedules, plumbing underfloor plans, mechanical systems, electrical plans, and comprehensive details for steel, concrete, and masonry construction. The project must comply with the 8th Edition Florida Building Code as adopted by Escambia County, with design parameters including ASD wind speeds of 121 mph and basic wind speeds of 156 mph per ASCE 7-22, ground-face CMU masonry construction with integral water repellent, structural steel framing with galvanized connections, and composite metal deck roofing. The drawings are marked "NOT FOR CONSTRUCTION" with an effective date of November 12, 2026, and include multiple revisions (ADD 01, dated 11/12/2026), indicating this is part of an active bid package.
The drawing set specifies design and construction requirements across all building systems, including 5-inch reinforced concrete slabs on grade, steel joist roof framing with 1.5-inch metal deck, masonry walls with continuous reinforcement and grouted cells in designated areas, and comprehensive mechanical, plumbing, and electrical systems. Special construction considerations include trench safety design requirements prepared by qualified professional engineers, temporary shoring and bracing under licensed engineer supervision, deferred submittals for concrete formwork and steel connections, and shop drawing approvals required before fabrication. Foundation design is based on geotechnical report #26-162 from Larry M Jacobs & Associates, Inc., with allowable soil bearing values of 1.5 ksf for footings and native soil sliding resistance coefficients specified. The project incorporates Section 3 provisions, Davis-Bacon wage requirements, and federal compliance measures including E-Verify and suspension and debarment verification, with liquidated damages applicable and substantial completion timelines established based on individual lot specifications from Notice to Proceed.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
7. FLOOD DESIGN DATA:
THIS PROJECT IS NOT LOCATED WITHIN A FLOOD HAZARD AREA
8. SPECIAL LOADS:
VEHICULAR BARRIERS
AREA
AWNINGS & CANOPIES
UNIFORM
20 psf
6.0 ksf
CONCENTRATED
300 lbs.
IMPACT SECTION OF CODE
FBC 1607.9
FBC 1607.13.4
9. ROOF RAIN LOAD DATA:
RAIN INTENSITY (15-DURATION)
4.9 in/hr
DESIGN DATA
1. THE DESIGN OF THE STRUCTURE AND PARTS THEREOF IS IN ACCORDANCE WITH THE 8TH EDITION OF FLORIDA BUILDING
CODE, AS AMENDED AND ADOPTED BY ESCAMBIA COUNTY.
2. FLOOR LIVE LOADS.
AREA UNIFORM CONCENTRATED
OFFICES
IMPACT LIVE LOAD REDUCTION
50 psf 2.0 -kips
OFFICE CORRIDORS 1ST FLOOR 2.0 -kips
OFFICE CORRIDORS OTHER FLOORS -
- kipsASSEMBLY AREAS -
-STORAGE LIGHT - kips -
100 psf
80 psf
100 psf
125 psf
2.0 kips
3. ROOF LIVE LOADS:
AREA UNIFORM SPECIAL COMMENTS
ROOF, GENERAL
LIVE LOAD REDUCTION
20 psf -
ROOF, EQUIP LOADS SEE ROOF PLAN
4. SNOW LOADS: NOT APPLICABLE PER FBC
FACTORED COMPONENTS AND CLADDING WALL LOADS
POSITIVE PRESSURE (psf) NEGATIVE PRESSURE (psf)
AREA (SQ FT)
LESS THAN 10
GREATER THAN 500
INTERIOR & CORNER ZONE INTERIOR ZONE CORNER ZONE
50 -54
-49
-44
-41 -41
-47
-56
-65
CORNER ZONE IS A DISTANCE OF 3'-0" FROM WALL CORNERS
LINEAR INTERPOLATE FOR LOADS BETWEEN SPECIFIED AREAS
6. SEISMIC DESIGN DATA: NOT APPLICABLE PER FBC
PERIMETER ZONE, "B" IS A DISTANCE OF 21'-6" FROM EDGE OF BUILDING
CORNER ZONE, "5'-3" IS A DISTANCE OF 15'-6" FROM EDGE OF BUILDING
LINEAR INTERPOLATE FOR LOADS BETWEEN SPECIFIED AREAS
23 3
33 B
B
B
C
ROOF WIND LOAD LAYOUT
YES, PER FBC 1607.13.1
YES, PER FBC 1607.13.1
YES, PER FBC 1607.13.1
YES, PER FBC 1607.13.1
YES, PER FBC 1607.13.1.2
YES, PER FBC 1607.14
FACTORED COMPONENTS AND CLADDING ROOF LOADS
POSITIVE PRESSURE (psf) NEGATIVE PRESSURE (psf)
AREA (SQ FT)
LESS THAN 10
GREATER THAN 500
ALL ZONES 1, 2, & 3
ZONE 1
-95
-68
-59
ZONE 2
-125
-98
-90
-80
ZONE 3
-170
-117
-101
-80
-74
RAIN INTENSITY (60-DURATION)
9.12 in/hr
5. WIND DESIGN DATA:
ASD WIND SPEED Vasd 121 mph
RISK CATEGORY
BASIC WIND SPEED (3 SECOND GUST)
WIND EXPOSURE
INTERNAL PRESSURE COEFFICIENT
COMPONENTS AND CLADDING
156 mph
+/- 0.18
PER ASCE 7-22
N/A
N/A
TORNADO SPEED, Vt
EFFECTIVE PLAN AREA
II
C
SEISMIC IMPORTANCE FACTOR, Ie
MAPPED SPECTRAL RESPONSE ACCEL.
RISK CATEGORY
SITE CLASS
SPECTRAL RESPONSE COEFFICIENTS
SEISMIC DESIGN CATEGORY
Ss =
BASIC SEISMIC-FORCE-RESISTING SYSTEM
DESIGN BASE SHEAR
SEISMIC RESPONSE COEFFICIENT, Cs
RESPONSE MODIFICATION FACTOR, R
ANALYSIS PROCEDURE USED
SDS =
S1 =
SD1 =
0.11 0.063
0.090.1
0.07xW (R=1.5) 0.03W (R=3)
1.0
II
DEFAULT
B
ORDINARY PLAN MASONRY SHEAR
WALL AND STEEL SYSTEMS NOT
SPECIFICALLY DETAILED FOR
SEISMIC RESISTANCE
1.5 (SHEAR)
3 (STEEL)
EQUIVALENT LATERAL FORCE
0.07xW (R=1.5) 0.03W (R=3)
1. PROJECT SPECIFICATIONS ARE A PART OF THE CONTRACT DOCUMENTS. CONTRACTOR SHALL REVIEW THE SPECIFICATIONS AND NOTIFY ARCHITECT OF DISCREPANCIES BEFORE PROCEEDING WITH WORK.
2. STRUCTURAL DRAWINGS ARE AN INTEGRAL COMPONENT TO THE CONTRACT DOCUMENTS. CONTRACTOR SHALL
REVIEW AND COORDINATE ACCORDINGLY.
A. PRIOR TO FABRICATION OR INSTALLATION OF STRUCTURAL MEMBERS, CONTRACTOR SHALL COMPARE
STRUCTURAL DIMENSIONS AND SECTIONS WITH ARCHITECTURAL DIMENSIONS AND SECTIONS.
DISCREPANCIES ARE TO BE REPORTED IN WRITING TO THE ARCHITECT.
B. PRINCIPAL OPENINGS ARE SHOWN ON THESE DRAWINGS. REFER TO ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR OTHER OPENINGS NOT SHOWN.
C. REFER TO ARCHITECTURAL DRAWINGS FOR ELEVATIONS AND LOCATIONS OF SLAB DEPRESSIONS AND
CURBS NOT SHOWN. PROVIDE POSITIVE SLOPE TO ALL DRAINS.
D. CONTRACTOR SHALL COORDINATE PENETRATIONS, SLEEVES, CURBS, AND INSERTS REQUIRED FOR THE
CONTRACT DOCUMENTS.
E. CONTRACTOR SHALL VERIFY SIZE, WEIGHT, LOCATION, AND SUPPORT CONDITIONS OF MECHANICAL
EQUIPMENT SUPPORTED ON OR SUSPENDED FROM THE ROOF OR FLOORS.
F. CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ADJACENT STRUCTURES AND UTILITIES.
G. CONTRACTOR SHALL NOTIFY IN WRITING THE ARCHITECT & ENGINEER OF ANY DISCREPANCIES BEFORE
PROCEEDING WITH WORK.
3. TEMPORARY SHORING AND BRACING DURING CONSTRUCTION
A. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING OF COMPONENTS DURING CONSTRUCTION TO MEET
REGULATORY REQUIREMENTS FOR SAFETY.
B. CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND BRACING OF WALLS AND GRADE BEAMS DURING
CONSTRUCTION. SHORE WALLS AND GRADE BEAMS DURING THE BACKFILLING AND COMPACTION PROCESS.
C. CONTRACTOR SHALL PROVIDE NECESSARY TEMPORARY BRACING AND SHORING DURING CONSTRUCTION
UNTIL STRUCTURAL FRAMING AND DIAPHRAGMS ARE COMPLETED. TEMPORARY BRACING SHALL BE
DESIGNED UNDER THE SUPERVISION OF A LICENSED ENGINEER.
4. SELECTION OF CONSTRUCTION MEANS, METHODS, TECHNIQUES, AND PROCEDURES, AS WELL AS SAFETY PRECAUTIONS AND PROGRAMS, ARE SOLELY THE CONTRACTOR’S RESPONSIBILITIES. AS SUCH, CONSTRUCTION ENGINEERING AND DESIGN RESULTING FROM THESE SELECTIONS IS THE RESPONSIBILITY OF THE CONTRACTOR.
A. EXAMPLES INCLUDE, BUT ARE NOT LIMITED TO, ENGINEERING OF SHORING AND SCAFFOLDING SYSTEMS;
LOAD CHECKS AND STRUCTURAL MODIFICATIONS FOR STORAGE, STAGING, AND CONSTRUCTION
EQUIPMENT LOADING; MEANS OF EGRESS FOR HEAVY EQUIPMENT; CRANE SELECTION, LOCATION, SUPPORT
AND BRACING; TEMPORARY HOISTS, LIFTS AND PLATFORMS.
B. CONTRACTOR SHALL ENSURE THAT APPROPRIATE ENGINEERING IS PERFORMED BY A LICENSED ENGINEER FOR THE WORK, CONSULTED WITH ON FIELD MODIFICATIONS, SPECIFY APPROPRIATE LEVELS OF
INSPECTION OF THE WORK, AND TO REVIEW INSPECTION REPORTS.
C. CONSTRUCTION ENGINEERING FEES HAVE NOT BEEN INCLUDED IN THE BASE FEE TO THE
OWNER/ARCHITECT. IF REQUESTED, THE EOR MAY CONSIDER PERFORMING THESE SERVICES AS AN
ADDITIONAL SERVICE PAID BY THE CONTRACTOR.
5. PRE-CONSTRUCTION MEETINGS SHALL BE CONDUCTED TO DISCUSS SUBGRADE PREPARATION, FOUNDATION CONSTRUCTION, WALL BACKFILL, VOID FORM SYSTEMS, CONCRETE FORMING & PLACING, AND TESTING &
INSPECTION REQUIREMENTS.
6. CONTRACTOR SHALL COMPLY WITH REQUIREMENTS AS LISTED IN THE STATEMENT OF SPECIAL INSPECTIONS.
GENERAL NOTES
1. DEFERRED SUBMITTALS ARE PORTIONS OF THE OVERALL DESIGN WHICH ARE NOT SUBMITTED AT TIME OF PERMIT
APPLICATION AND ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL.
2. DEFERRED SUBMITTALS WILL BE REVIEWED FOR THE LIMITED PURPOSE OF CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. SUBMITTAL REVIEW WILL NOT BE CONDUCTED FOR THE PURPOSE OF DETERMINING THE ACCURACY AND COMPLETENESS OF OTHER DETAILED INFORMATION SUCH AS DIMENSIONS AND QUANTITIES, OR FOR SUBSTANTIATING INSTRUCTIONS FOR INSTALLATION OR SYSTEMS DESIGNED
BY THE CONTRACTOR WHICH REMAINS THE RESPONSIBILITY OF THE CONTRACTOR.
REVIEW SHALL NOT CONSTITUTE APPROVAL OF SAFETY PRECAUTIONS OR OF ANY CONSTRUCTION MEANS, METHODS, SEQUENCES OR PROCEDURES.
APPROVAL OF A SPECIFIC ITEM SHALL NOT INDICATE APPROVAL OF AN ASSEMBLY OF WHICH THE ITEM IS A
COMPONENT.
3. FOLLOWING DEFERRED SUBMITTALS ARE TO BE PROVIDED FOR REVIEW:
A. CONCRETE FORMWORK / RETENTION SYSTEMS
B. STEEL BEAM AND VERTICAL BRACING CONNECTIONS
C. STEEL FRAMING CONNECTION CALCULATIONS
SUPPLIER’S ENGINEERS SHALL PROVIDE SIGNED AND SEALED CALCULATIONS WITH THE SUBMITTAL FOR REVIEW.
REVIEW WILL BE LIMITED TO CONFORMANCE WITH DESIGN AND PERFORMANCE CRITERIA SPECIFIED IN THE CONSTRUCTION DOCUMENTS AND THE INTERFACE BETWEEN THESE ITEMS/SYSTEMS AND THE BUILDING STRUCTURE. THE MANUFACTURER/SUPPLIER AND ITS SPECIALTY STRUCTURAL ENGINEER REMAIN RESPONSIBLE FOR THE DESIGN OF THE ITEM/SYSTEM WILL RETAIN ALL RIGHTS AND RESPONSIBILITIES FOR THE DESIGN OF THE
PRODUCT AND THE CONNECTIONS TO THE BUILDING STRUCTURE.
NO WORK ON STRUCTURAL ELEMENTS SUPPORTING OR RELATED TO THESE ITEMS IS TO PROCEED UNLESS THE REVIEW STAMP CLEARLY INDICATES "REVIEWED" OR "REVIEWED, SEE COMMENTS" BY THE ENGINEER.
4. FOLLOWING SHOP DRAWINGS ARE TO BE PROVIDED FOR APPROVAL:
A. CONCRETE MIXES
B. REINFORCING STEEL
C. STRUCTURAL STEEL
D. STEEL JOISTS AND JOIST GIRDERS
E. METAL DECKING
F. MASONRY WALL REINFORCING
SHOP DRAWINGS ARE TO BE DISTRIBUTED ONLY FROM RETURNED SUBMITTALS BEARING AN INITIALED REVIEW STAMP AND WORK ON THESE ITEMS SHALL NOT PROCEED UNLESS THE STAMP CLEARLY INDICATES THE DRAWINGS
ARE "APPROVED" OR "APPROVED AS NOTED."
5. CONCRETE IS A MATERIAL DESIGNED BY THE SUPPLIER TO MEET THE STRENGTH AND PERFORMANCE CRITERIA SPECIFIED IN THE CONTRACT DOCUMENTS. CONCRETE MIX DESIGNS SHALL BE IN CONFORMANCE WITH ACI 318.
SUBMIT MIX DESIGNS AND THE TESTING LAB REVIEW TO THE ARCHITECT/ENGINEER FOR REVIEW.
MANY VARIABLES, INCLUDING ENVIRONMENTAL CONDITIONS AFFECT THE QUALITY OF CONCRETE. THE CONTRACTOR IS RESPONSIBLE FOR CONTROLLING VARIABLES AND REQUESTING MIX MODIFICATIONS AND SHALL BE
SOLELY RESPONSIBLE FOR THE QUALITY OF CONCRETE DELIVERED AND PLACED ON THE SITE.
6. BEFORE SUBMISSION FOR REVIEW, GENERAL CONTRACTOR SHALL PRE-CHECK SUBMITTALS. SUBMITTALS MUST BEAR AN INITIALED REVIEW STAMP OF THE GENERAL CONTRACTOR. SUBMITTALS WITHOUT REVIEW STAMPS WILL
BE RETURNED WITHOUT REVIEW AND SHALL NOT BE CAUSE FOR CLAIMS OF DELAY.
7. SCHEDULE SUBMITTALS SUFFICIENTLY IN ADVANCE OF THE DATE REQUIRED TO ALLOW REASONABLE TIME FOR PROCESSING AND REVIEW BY THE DESIGN TEAM. THIS SHALL INCLUDE A MINIMUM OF TEN WORKING DAYS FOR ENGINEER'S PROCESSING AND REVIEW. INCLUDE TIME FOR CONTRACTOR’S RESUBMISSION AND SUBSEQUENT
REVIEW IF NECESSARY.
SHORTER REVIEW PERIODS WILL ONLY BE HONORED WITH PRIOR WRITTEN CONSENT. THESE ACCELERATED SERVICES, AND APPROPRIATE COMPENSATION, MUST BE NEGOTIATED WITH THE ENGINEER AND ARCHITECT IN
ADVANCE.
TEN DAY REVIEW PERIODS CAN NOT BE HONORED WHEN LARGE QUANTITIES OF SHOP DRAWINGS ARE SUBMITTED AT ONE TIME. WHEN THIS HAPPENS, THE CONTRACTOR SHALL SUBMIT AN ITEMIZED LIST INDICATING PRIORITIES AND
REASONABLE RETURN DATES.
REVIEW OF RESUBMITTALS WILL BE LIMITED TO ONLY EARLIER COMMENTS AND IS NOT AN EXTENSIVE REVIEW.
8. USE OF REPRODUCTIONS OF THESE CONTRACT DRAWINGS, INCLUDING THE USE OF ELECTRONIC FILES, BY ANY CONTRACTOR IN LIEU OF THE INDEPENDENT PREPARATION OF SHOP DRAWINGS, SIGNIFIES THEIR ACCEPTANCE OF ALL INFORMATION SHOWN HEREON AS CORRECT AND OBLIGATES HIMSELF TO ANY JOB EXPENSE, REAL OR IMPLIED, ARISING DUE TO ANY ERRORS THAT MAY OCCUR HEREON.
9. NOT USED
DEFERRED SUBMITTALS NOTES
1. FOUNDATION DESIGN AND SUBSURFACE INFORMATION IS BASED ON GEOTECHNICAL REPORT #26-162 PREPARED FOR THIS PROJECT BY LARRY M JACOBS & ASSOCIATES, INC AND DATED MAY 1, 2026 & EMAIL RESPONSE DATED
SEPTEMBER 1, 2026.
2. GEOTECHNICAL ENGINEER OF RECORD (GER) IS SOLELY RESPONSIBLE FOR ESTABLISHING FOUNDATION, SLAB-ON- GRADE AND PAVEMENT DESIGN CRITERIA, AND FOR THE CONSTRUCTION RECOMMENDATIONS FOR EXCAVATION, SUBGRADE PREPARATION, BACKFILLING AND COMPACTION.
3. GEOTECHNICAL INFORMATION INDICATED IN THE STRUCTURAL CONSTRUCTION DOCUMENTS IS INTENDED TO REPLICATE THE RECOMMENDATIONS STATED IN THE GEOTECHNICAL ENGINEERING REPORT. PRESENTATION OF THIS INFORMATION IN THE STRUCTURAL DOCUMENTS DOES NOT DEMONSTRATE, STATE OR IMPLY GEOTECHNICAL EXPERTISE BY THE STRUCTURAL ENGINEER. CONTRACTOR SHALL OBTAIN A COPY OF THE REPORT AND COMPLY
WITH THE RECOMMENDATIONS INDICATED THEREIN.
4. IF DISCREPANCIES BETWEEN THE REPORT AND CONSTRUCTION DOCUMENTS ARE DISCOVERED, THE REPORT SHALL GOVERN. ALL CLARIFICATIONS AND INTERPRETATIONS OF THE REPORT SHALL BE MADE BY THE GER AND
REPORTED TO THE ARCHITECT FOR COORDINATION WITH THE DESIGN TEAM.
GEOTECHNICAL INFORMATION
1. BEARING STRATA SHOWN ON THE DETAILS IS COMPACTED NATIVE SOILS. PREPARE FOUNDATION BEARING
MATERIAL PER THE GEOTECHNICAL ENGINEER'S RECOMMENDATIONS.
2. FOUNDATION ALLOWABLE DESIGN SOIL VALUES:
CONTINUOUS FOOTING BEARING - 1.5ksf * ISOLATED FOOTING BEARING - 1.5ksf *
SOIL SLIDING RESISTANCE (NATIVE SOIL) 0.5
* IF CONTINUOUS FOOTING OR ISOLATED FOOTING WIDTH EXCESS 3FT IN DIMENSION, THE SOIL BENEATH FOOTING
SHALL HAVE ADDITIONAL 2FT OF SOIL COMPACTION PER GEOTECHNICAL REPORT.
RETAINING WALL DESIGN VALUES
SOIL DENSITY Yd- 95PCF (VERY LOOSE SLIGHTLY SILTY SAND) AT REST Ka- 0.4xYd PASSIVE PRESSURE Kp- 2.5XYd
3. ALL FOOTING EXCAVATIONS SHALL BE CLEANED TO REMOVE ALL LOOSE SOIL MATERIAL AND OTHER DEBRIS AND
SHOULD NOT BE ALLOWED TO DESICCATE PRIOR TO PLACEMENT OF CONCRETE.
4. CONCRETE FOR FOUNDATIONS SHALL BE FORMED ON THE SIDES (EARTH FORMED FOUNDATIONS WILL NOT BE
ALLOWED). PROPERLY PLACE AND COMPACT FILL MATERIAL AROUND SIDES OF FOOTINGS.
5. ALL FOUNDATION EXCAVATIONS SHALL BE INSPECTED BY THE TESTING AGENCY.
SHALLOW FOUNDATION NOTES
1. STRUCTURAL MASONRY SHALL CONFORM TO "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES" ACI
530 / ASCE 5 - LATEST EDITION.
2. HOLLOW LOAD BEARING MASONRY UNITS SHALL CONFORM TO ASTM C90, LIGHTWEIGHT, TYPE N, WITH A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2000 psi ON THE NET AREA OF THE BLOCK. DESIGN BASED ON AN ULTIMATE COMPRESSIVE STRENGTH f'm = 2500 psi.
3. MORTAR SHALL CONFORM TO ASTM C270, TYPE M OR S.
4. GROUT SHALL CONFORM TO ASTM A476 WITH A MINIMUM COMPRESSIVE STRENGTH OF 2500 psi. USE COARSE GROUT IN TYPICAL APPLICATION. USE FINE GROUT IN 4" AND 6" CMU WALLS AND IN ANY CELL REINFORCED WITH
MORE THAN ONE BAR.
5. REFER TO REINFORCING STEEL NOTES FOR REINFORCEMENT USED IN MASONRY CONSTRUCTION. ALL REINFORCING TO BE GRADE 60. PRIOR TO FABRICATION SUBMIT SHOP DRAWINGS FOR REVIEW, INCLUDING WALL
ELEVATIONS SHOWING ALL REINFORCING STEEL.
6. VERTICAL REINFORCING SHALL BE #6 BARS AT A MAXIMUM SPACING OF 40" O.C., UNLESS OTHERWISE NOTED ON DRAWINGS. THE FIRST CELL AT CORNERS AND ENDS OF WALLS SHALL BE REINFORCED WITH 1-#6 BAR AND GROUTED FULL. ON EACH SIDE OF WALL OPENINGS 1-#5 BAR EXTENDING 2'-0" BEYOND CORNERS OF OPENING SHALL BE PLACED. ALL REINFORCED CELLS SHALL BE FILLED SOLIDLY WITH GROUT. REFER TO DETAILS FOR
SPECIAL REINFORCEMENT AT SUPPORTS.
7. REINFORCING BARS SHALL BE STRAIGHT EXCEPT FOR BENDS AROUND CORNERS AND WHERE BENDS OR HOOKS
ARE DETAILED ON THE PLANS.
8. REINFORCING STEEL SHALL BE LAPPED 60 BAR DIAMETERS WHERE SPLICED AND SHALL BE WIRED TOGETHER.
9. HORIZONTAL WALL REINFORCING SHALL BE EXTRA HEAVY HOHMANN & BARNARD COMPANY (LADUR TYPE) AT 1'-4" O.C. FOR 12" CMU AND STANDARD HOHMANN & BARNARD COMPANY (LADUR TYPE) AT 1'-4" O.C. FOR 8" CMU. IN LIEU OF HOHMANN & BARNARD COMPANY REINFORCEMENT THE CONTRACTOR MAY PROVIDE HORIZONTAL BOND BEAMS
LOCATED 48" O.C. VERTICALLY AND REINFORCED WITH 2-#5 CONTINUOUS BARS.
10. ALL REINFORCING SHALL BE IN PLACE PRIOR TO GROUTING. VERTICAL REINFORCING BARS SHALL BE HELD IN POSITION AT TOP, BOTTOM, AND AT INTERVALS NOT FURTHER APART THAN 192 BAR DIAMETERS BY WALL-BRAC VERTICAL STEEL POSITIONER AS MANUFACTURED BY W.C.R. FABRICATORS, OR AN EQUIVALENT POSITIONER.
11. PROVIDE CONTINUOUS CMU BOND BEAMS (8" MIN. DEPTH) REINFORCED WITH 2-#5 CONTINUOUS BARS AT TOP OF PARAPETS AND AT ROOF FRAMING ELEVATION FOR FULL LENGTH OF ALL WALLS. WHERE BOND BEAMS REQUIRE SLOPES, PROVIDE 16" DEEP BOND BEAM AND CUT TO PROVIDE AN 8" MINIMUM DEPTH. CONTINUE HORIZONTAL
REINFORCEMENT THROUGH MASONRY COLUMNS AND PILASTERS.
12. PROVIDE 2-#5 CORNER BARS (2'-6"x2'-6"), LAP WITH CONTINUOUS BARS IN ALL BOND BEAMS AT CORNERS AND WALL
INTERSECTIONS.
13. PROVIDE VERTICAL CONTROL JOINTS IN ALL MASONRY WALLS WHERE SHOWN ON ARCHITECTURAL OR STRUCTURAL DRAWINGS, AND NOT TO EXCEED 30 FEET O.C. PROVIDE MATCHING CONTROL JOINTS IN FINISH MATERIALS (i.e. BRICK, STUCCO, etc.). VERTICAL CELLS ON EACH SIDE OF CONTROL JOINTS SHALL BE REINFORCED
AND GROUTED TO MATCH THE TYPICAL WALL REINFORCEMENT.
14. AT WALL CONTROL JOINTS, CONTINUE BOND BEAM REINFORCEMENT THROUGH JOINT AND DISCONTINUE ALL OTHER
HORIZONTAL WALL REINFORCING AT JOINT.
15. ALL UNITS SHALL BE LAID WITH FULL MORTAR BEDS ON THE FACE SHELLS. ALL HEAD JOINTS SHALL BE FILLED SOLIDLY WITH MORTAR FOR A DISTANCE IN FROM THE FACE OF THE UNIT NOT LESS THAN THE THICKNESS OF THE LONGITUDINAL FACE SHELLS. UNLESS THE WALL IS TO BE POURED SOLID, END WALLS AND CROSS WEBS FORMING
CELLS TO BE FILLED SHALL BE FULLBEDDED IN MORTAR TO PREVENT LEAKAGE OF GROUT.
16. ALL DOWELS, ANCHOR BOLTS, AND HEADED STUDS SHALL BE SET IN SOLID GROUTED CELLS.
17. GROUT ALL CELLS SOLID BELOW GRADE.
LOAD BEARING STRUCTURAL MASONRY
1. STRUCTURAL STEEL SHALL CONFORM TO AISC "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS," ANSI/AISC 360, LATEST EDITION.
2. BOLTS AND BOLTED CONNECTIONS SHALL CONFORM TO THE REQUIREMENTS OF THE "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS," APPROVED BY THE RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS, LATEST EDITION. CONNECTIONS SHALL BE BEARING TYPE UNLESS NOTED OTHERWISE IN
DRAWINGS.
3. ALL W SHAPES SHALL CONFORM TO ASTM A992.
ALL OTHER STRUCTURAL STEEL SHAPES, PLATES, ETC., SHALL CONFORM TO ASTM A36, UNLESS NOTED
OTHERWISE.
4. ALL STRUCTURAL STEEL TUBE MEMBERS SHALL CONFORM TO ASTM A500, GRADE C.
5. ALL STRUCTURAL STEEL PIPE SHALL CONFORM TO ASTM A53, GRADE B.
6. ALL STRUCTURAL ROUND SHAPES SHALL CONFORM TO ASTM A53, GRADE B.
7. GALVANIZING OF STEEL MEMBERS SHALL CONFORM TO ASTM A123/A123M. ALL STEEL FRAMING THAT COMES IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE COATED TO A G90 THICKNESS AND ALL BOLTS, HEADED STUDS AND CONNECTORS SHALL BE COATED TO A G185 THICKNESS. ALL EXPOSED STRUCTURAL STEEL FRAMING AND ACCESSORIES FOR MECHANICAL EQUIPMENT SUPPORTS SHALL BE HOT-DIP GALVANIZED AFTER FABRICATION.
CONTRACTOR TO PROVIDE BOLTS AND PUNCH BEAMS AS REQUIRED BY EQUIPMENT MANUFACTURER'S DETAILS.
8. ALL STRUCTURAL STEEL DETAILS AND CONNECTIONS SHALL CONFORM TO THE STANDARDS OF THE AISC.
9. STEEL MEMBERS SHALL NOT BE SPLICED EXCEPT WHERE SHOWN ON THE DRAWINGS.
10. ALL STEEL BEAMS SHALL BE ERECTED WITH NATURAL CAMBER UP.
11. WELDED CONSTRUCTION SHALL CONFORM TO THE AMERICAN WELDING SOCIETY "STRUCTURAL WELDING CODE", D1.1. ELECTRODES FOR FIELD AND SHOP WELDS SHALL BE E70XX, UNLESS NOTED OTHERWISE.
12. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS.
13. FULL AND PARTIAL PENETRATION WELDS PERFORMED IN THE FIELD SHALL BE ULTRASONICALLY TESTED.
14. WHEN WELDS ARE NOT CALLED-OUT ON DRAWINGS, THEY ARE MINIMUM SIZE CONTINUOUS FILLET WELDS IN
ACCORDANCE WITH AWS D1.1.
15. THE STEEL FABRICATOR IS RESPONSIBLE FOR COORDINATION WITH THE MANUFACTURER OF STEEL JOISTS AND
JOIST GIRDERS.
16. TEMPORARY SUPPORTS, SUCH AS TEMPORARY GUYS, BRACES, FALSEWORK, CRIBBING OR OTHER ELEMENTS REQUIRED FOR THE ERECTION OPERATION WILL BE DETERMINED, FURNISHED, AND INSTALLED BY THE ERECTOR.
THESE TEMPORARY SUPPORTS SHALL BE CAPABLE OF SECURING THE STEEL FRAMING, OR ANY PARTLY ASSEMBLED STEEL FRAMING, AGAINST LOADS COMPARABLE IN INTENSITY TO THOSE FOR WHICH THE STRUCTURE
WAS DESIGNED, RESULTING FROM WIND, SEISMIC FORCES AND ERECTION OPERATIONS.
17. THE LIFTING AND ERECTION OF PRE-ASSEMBLED ELEMENTS SUCH AS TRUSSES OR PRE-FABRICATED FRAMING ARE CONSIDERED SPECIAL ERECTION CONDITIONS. THE SELECTION OF LIFT POINTS AND ERECTION TECHNIQUES ARE THE RESPONSIBILITY OF THE CONTRACTOR. LOCATE AND PROVIDE SUFFICIENT LIFT POINTS TO PREVENT OVERSTRESS AND/OR DISTORTION OF ANY COMPONENTS WITHIN THE ASSEMBLY. PROVIDE TEMPORARY STRONG-
BACKS, STIFFENERS AND/OR LIFTING DEVICES AS REQUIRED.
18. ALL GROUT BELOW ALL COLUMN BASE PLATES AND BEARING PLATES SHALL BE NON-SHRINK, NON-METALLIC GROUT
UNLESS NOTED OTHERWISE.
STRUCTURAL STEEL NOTES
1. FLOOR SLAB SHALL BE 5" THICK CONCRETE SLAB OVER A 15 MIL VAPOR RETARDER, OVER SUBGRADE PREPARED PER THE GEOTECHNICAL ENGINEER'S RECOMMENDATIONS. TAPE ALL SEAMS, PENETRATIONS AND TEARS IN
THE VAPOR RETARDER WITH A COMPATIBLE WATERPROOF TAPE.
2. REINFORCE SLAB WITH #3 @ 18" CTRS. EACH WAY PLACED AND SUPPORTED ON CHAIRS OR CONCRETE BRIQUETS, AT SLAB MID DEPTH.
3. PROVIDE ONE OF THE FOLLOWING JOINTS ON THE CENTERLINE OF ALL COLUMNS, AND @ 15' O.C. MAXIMUM.
A. CONSTRUCTION JOINTS WHERE DETAILED ON DRAWINGS.
B. SAW CUT CONTROL JOINTS ELSEWHERE 1 1/4" DEEP OR ONE QUARTER OF THE SLAB DEPTH DEEP, WHICHEVER IS GREATER.
4. A METAL CONTROL JOINT FORM MAY BE USED IN LIEU OF EITHER OF THE ABOVE.
5. CUT SAW CUT JOINTS WITHIN 8 HOURS OF POURING CONCRETE.
6. CONCRETE FINISHES AND SPRAY ON CURRING / SEALING COMPOUNDS SHALL BE COORDINATED WITH
ARCHITECTURAL FLOORING FINISHES FOR COMPATIBILITY.
SLAB-ON-GRADE NOTES
1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 318- PER GOVERNING BUILDING CODE.
2. CONCRETE IN THE FOLLOWING AREAS SHALL HAVE SAND AND GRAVEL OR CRUSHED STONE AGGREGATES AND THE DESIGNATED COMPRESSIVE STRENGTH IN 28 DAYS UNLESS NOTED OTHERWISE. NORMAL WEIGHT AGGREGATES
SHALL CONFORM TO ASTM C33.
FOOTING AND SLABS ON GRADE --------------------------- f'c = 4,000 psi ALL OTHER CONCRETE ---------------------------------------- f'c = 4,000 psi
3. CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE AS FOLLOWS:
REFER TO ACI 318 - SECTION 7.7 FOR CONDITIONS NOT NOTED.
FOOTINGS ---------------------------------------- 3"
SLABS-ON-GRADE ----------------------------- CENTERED
4. MAXIMUM NOMINAL COARSE AGGREGATE SIZE SHALL BE 1 1/2" MAX FOR PIERS AND 1" MAX TYPICAL UNLESS NOTED
OTHERWISE.
5. CONCRETE SLUMPS SHALL BE AS FOLLOWS:
CONCRETE CONTAINING HRWR------ 10" MAX
ALL OTHER CONCRETE ---------------- 5" MAX, 2" MIN
6. CONCRETE EXPOSED TO WEATHER SHALL BE AIR-ENTRAINED AS FOLLOWS:
3/4" NOMINAL AGGREGATE SIZE 4% TO 8%
1" NOMINAL AGGREGATE SIZE 3.5% TO 6.5%
1 1/2" NOMINAL AGGREGATE SIZE 3% TO 6%
7. ALL FOUNDATION PIER CAPS SHALL BE FORMED ON SIDES. ALL ELEMENTS OF THE FORMS, FORMWORK, BRACING AND SHORING SHALL CONSIST OF WOOD, METAL OR OTHER MANUFACTURED PRODUCTS AS SPECIFIED. EARTH MAY NOT BE USED AS A FORM, EITHER DIRECTLY OR INDIRECTLY. NEITHER EARTH TRENCHES NOR EARTH TRENCHES
LINED WITH ANOTHER MATERIAL ARE ACCEPTABLE.
8. THERE SHALL BE NO HORIZONTAL CONSTRUCTION JOINTS IN CONCRETE POURS. ALL CONSTRUCTION JOINTS SHALL BE MADE IN THE CENTER OF SPANS WITH VERTICAL BULK HEADS. THE LOCATION OF CONSTRUCTION JOINTS SHALL
BE APPROVED BY THE STRUCTURAL ENGINEER.
9. ALL CONSTRUCTION JOINTS SHOWN ON THE DRAWINGS SHALL BE INCORPORATED IN THE STRUCTURE UNLESS OTHERWISE APPROVED BY THE ENGINEER OF RECORD. ADDITIONAL CONSTRUCTION JOINTS REQUIRED TO FACILITATE CONSTRUCTION SHALL BE LOCATED AND DETAILED ON SHOP DRAWINGS. WHEN CONSTRUCTION JOINTS OTHER THAN THOSE SHOWN ON THE CONSTRUCTION DOCUMENTS ARE REQUIRED, THE REINFORCEMENT SHALL PASS CONTINUOUSLY THROUGH JOINT AND A KEY SHALL BE PROVIDED FOR ADEQUATE SHEAR TRANSFER.
10. UNLESS OTHERWISE NOTED OR DETAILED, PROVIDE (2)#5, (1) EACH FACE AROUND UNFRAMED OPENINGS IN CONCRETE WALLS AND GRADE BEAMS. PLACE BARS PARALLEL TO SIDES OF OPENINGS AND EXTEND 24 INCHES
BEYOND CORNERS.
11. PROVIDE EQUIPMENT BASES AND SUPPORTS AS REQUIRED, COMPLYING WITH APPROVED MANUFACTURERS
CERTIFIED SHOP DRAWINGS AND DETAILS.
12. SIZE AND LOCATION OF BASES AND EMBEDDED ANCHORS FOR EQUIPMENT SHALL BE COORDINATED WITH
EQUIPMENT SUPPLIER AND ALL BE IN ACCORDANCE WITH APPROVED SHOP DRAWINGS.
13. NO ALUMINUM OF ANY TYPE SHALL BE ALLOWED IN THE CONCRETE WORK, UNLESS COATED AND APPROVED BY
THE ENGINEER OR RECORD.
14. NO ELECTRICAL CONDUIT SHALL BE PLACE ABOVE THE WELDED WIRE FABRIC IN THE SLAB-ON-GRADE OR CONCRETE PLACED ON COMPOSITE METAL DECK. MAXIMUM SIZE OF CONDUIT SHALL BE 1/3 THE SLAB THICKNESS (ABOVE DECK ON COMPOSITE SLAB) INCLUDING CROSSOVERS. CONDUIT SHALL NOT BE PLACED CLOSER THAN 3
DIAMETERS ON CENTER.
CONCRETE NOTES
1. ALL REINFORCING STEEL SHALL BE NEW DEFORMED BILLET STEEL CONFORMING TO ASTM A615, GRADE 60.
2. DETAILING OF REINFORCEMENT SHALL BE IN ACCORDANCE WITH THE ACI DETAILING MANUAL.
3. REINFORCING BARS MAY BE SPLICED ONLY AS SHOWN ON THE DRAWINGS EXCEPT THAT REINFORCING DESIGNATED AS "CONTINUOUS" MAY BE CONTACT LAP SPLICED WITH TENSION LAP PER ACI 318 CHAPTER 25.
4. FOR CONTINUOUS FOOTING REINFORCING, PER FOOTING REINFORCEMENT LAP SPLICES SCHEDULED ON S301.
5. PROVIDE CORNERS BARS OF SAME SIZE AND QUANTITY AS CONTINUOUS TOP AND BOTTOM REINFORCING OF
GRADE BEAMS AT ALL GRADE BEAM CORNERS AND INTERSECTIONS.
REINFORCING STEEL NOTES
1. THE CONTRACTOR SHALL PROVIDE TRENCH SAFETY DESIGN DOCUMENTS PREPARED AND SEALED BY A QUALIFIED REGISTERED PROFESSIONAL ENGINEER AS REQUIRED BY ALL LOCAL AND STATE LAWS. SAID ENGINEER SHALL ALSO BE RESPONSIBLE FOR ON SITE OBSERVATIONS. THE TRENCH SAFETY DESIGN DOCUMENTS SHALL BE FILED WITH THE APPROPRIATE GOVERNMENT AGENCY. THE CONTRACTOR SHALL FURNISH A SEPARATE AND DISTINCT PRICE FOR TRENCH SAFETY SYSTEM THAT MEETS OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION STANDARDS.
TRENCH SAFETY
1. ALL SUBGRADE SHALL BE PREPARED IN STRICT CONFORMANCE TO THE GEOTECHNICAL ENGINEER’S RECOMMENDATIONS. REFER TO THE GEOTECHNICAL REPORT, SUPPLEMENTARY LETTERS AND SPECIFICATIONS
FOR ADDITIONAL INFORMATION.
THE SUBGRADE SHALL BE IMPROVED TO REDUCE THE POTENTIAL FOR SUBGRADE MOVEMENT TO LESS THAN OF ONE INCH TOTAL SETTLEMENT & 1/2 INCH OF DIFFERENTIAL SETTLEMENT BY RE-COMPACTING IN-SITU SOIL AS
APPROVED BY GEOTECH ENGINEER.
THE FOLLOWING IS A SUMMARY OF THE INFORMATION CONTAINED IN THE GEOTECHNICAL ENGINEER’S
RECOMMENDATIONS:
A. THE BUILDING EXCAVATION AREA SHALL EXTEND BEYOND THE BUILDING LINE A MINIMUM OF 5 FEET IN GENERAL. AT ALL ENTRANCES AND AT AREAS WITH SIDEWALKS/PAVING DIRECTLY ADJACENT TO THE
BUILDING.
B. WITHIN THE BUILDING AREA, EXCAVATE AND REMOVE ALL FILL MATERIAL. REFER TO THE GEOTECHNICAL REPORT FOR APPROXIMATE DEPTHS OF FILL. THE TESTING LAB SHALL DETERMINE THROUGH FIELD
OBSERVATION AND TESTING THAT ALL UNACCEPTABLE FILLS HAVE BEEN REMOVED.
C. WITHIN THE BUILDING AREA, RE-COMPACT NATIVE SOIL OR IMPORTED FILL AS REQUIRED TO PROVIDE A COMPACTED MATERIAL BENEATH BUILDING AREA. FOOTING THAT HAVE A WIDTH GREATER THAN 3FT IN
WIDTH WILL REQUIRE ADDITIONAL 2FT OF SOIL COMPACTION BENEATH FOOTING.
D. SCARIFY EXPOSED NATIVE SOILS TO A DEPTH OF 12 INCHES FOR FOOTING LESS THAN 3FT IN WIDTH AND RECOMPACT TO A MINIMUM OF 95% OF MODIFIED PROCTOR (ASTM D1557) AT A MINIMUM OF +2 PERCENTAGE POINTS ABOVE THE OPTIMUM MOISTURE CONTENT FOR THE SOIL AS DIRECTED IN THE
GEOTECHNICAL REPORT.
K. SELECT FILL SHALL CONSIST OF A SLIGHTLY SILTY SAND OR SILTY/CLAYEY SAND. ALL SELECT FILL SHALL BE
APPROVED BY THE GEOTECHNICAL ENGINEER.
L. SPREAD THE SELECT FILL IN THIN LOOSE LIFTS NOT EXCEEDING 10 TO 12 INCHES THICK FOR SLIGHTLY SILTY SAND OR LIFTS NOT EXCEEDING 6 TO 8 INCHES THICK FOR SILTY/CLAYEY SAND AND UNIFORMLY COMPACT TO A MINIMUM OF 95% OF ASTM D1557 WITHIN +2 OR –2 PERCENTAGE POINTS OF THE OPTIMUM MOISTURE
CONTENT FOR THE SOIL AS RECOMMENDED IN THE GEOTECHNICAL REPORT.
M. PLACE FIRST LIFT OF SELECT FILL WET OF OPTIMUM TO PREVENT DRYING OF THE UNDERLYING SUBGRADE.
N. PROTECT FILL TO PREVENT DESICCATION PRIOR TO PLACING A SUBSEQUENT LIFT.
2. CONTACT THE GEOTECHNICAL ENGINEER FOR ANY QUESTIONS REGARDING INTERPRETATION OR CLARIFICATION OF
THE ABOVE INFORMATION.
3. FOUNDATION AND SUBGRADE PREPARATION SHALL BE MONITORED AND TESTED BY THE SOILS ENGINEER. REFER
TO SPECIFICATIONS FOR QUALITY CONTROL REQUIREMENTS.
SUBGRADE PREPARATION
Architect of Record:
ADG
800 SW ADAMS STREET, SUITE 101
PEORIA, IL 61602
R e vi si o n s
P - 309.672.6948
Discipline:Discipline:Discipline:
P - P - P -
Discipline:
P -
PROJECT NO.
DATE
DRAWN BY
STATUS
Discipline: Owner Consultant
QSC SERVICES, LLC
PMB #69
545 BRENT LN. PENSACOLA, FL
P - 309.231.8272
OWNER ID:
Design and Construction Administration Division
ESCAMBIA COUNTY, FL
100 E. BLOUNT ST. PENSACOLA, FL 32501
ESCAMBIA COUNTY AREA TRANSIT - FACILITY:
03 - TRANSFER CENTER
41 CLARINDA LN
PENSACOLA, FL, 32505 S001GENERAL NOTES
KEDbluestone
707 NE JEFFERSON AVE,
PEORIA, IL 61602
RLG CONSULTING ENGINEERS
12001 N CENTRAL EXPY, STE 300
DALLAS, TX 75243
RLG CONSULTING ENGINEERS
12001 N CENTRAL EXPY, STE 300
DALLAS, TX 75243
214.739.8100 214.739.8100 515.727.0700
HODGSON DOUGLAS LANDSCAPE ARCHITECTS
12001 N CENTRAL EXPY, SUITE 1170
DALLAS, TX 75243
214.749.0333
BID PACKAGE #2 - NOT FOR CONSTRUCTION
10/22/2026
RLG
A D
D
.1
.1
ADD
ADD
A A
B B
T/STL EL =
110'-3 5/8"
T/STL EL =
110'-11 7/8"
T/STL EL =
113'-8"
T/STL EL =
112'-2 3/8"
32'-0" 32'-0" 32'-0" 32'-0" 32'-0" 32'-0" 32'-0" 32'-0"
LINE OF CANOPY
ROOF ABOVE
1 1/2" METAL
ROOF DECK
1 1/2" METAL
ROOF DECK
18K3 SP
18K3 SP
18K3 SP 18K3
18K3
18K3
W
X
W12X30
12K1
12K1SP
W
X
18K3
18K3
18K3
E
Q S
P A
/4
E
Q S
P A
/4
H S
S
X
X
/8
L
SLOPE SLOPE
S500
S302
TYP
S302
TYP
S302
12K1
E
Q S
P A
/8
/8
E
Q S
P A
/2
ARCH
REF
72'-0"
28'-0" 18'-8" 25'-4"
8'-0" 5'-4"
34'-8"
24'-0" 10'-8"
9'-4"
RTU
300 LBS
ROOF TIE BACK -
REF ARCH
S302
TYP AT
BEAM
S302
S302 TYP
TYP
S302
S302
S500
LOW
S500
E
Q S
P A
/4
8'-6" 5'-10"
ROOF HATCH OPNG -
SEE PLAN NOTE #5
S500
SEE 06/S303
FOR RTU
SUPPORT
NOTE #7
SEE PLAN
NOTE #7
SEE PLAN
EF-2
150LB
S500
SEE PLAN
NOTE #8
PLAN NOTES:
1. ALL ELEVATIONS ARE REFERENCED TO BUILDING 1 LEVEL 1 FINISHED FLOOR
EL = 100'-0" (79.30'). REFERENCE SITE PLAN FOR ABSOLUTE ELEVATIONS.
2. SEE S000 SERIES FOR ABBREVIATIONS, GENERAL NOTES, AND SPECIAL
3. SEE S300 SERIES SHEETS FOR TYPICAL DETAILS.
INSPECTIONS.
4. XXX'-X" - DENOTES TOP OF STEEL ELEVATION (METAL DECK BEARING).
5. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF ROOF HATCH OPENINGS.
PROVIDE FRAMING AROUND ROOF OPENINGS PER DETAIL 04 AND 07/S303.
6. JOIST DESIGNATED WITH THE "SP" IDENTIFIER SHALL BE ENGINEERED TO
ACCOMMODATE SUPPLEMENTAL LOADING CONDITIONS. CONTRACTOR TO
VERIFY/COORDINATE LOCATIONS WITH MEP DRAWINGS AND JOIST ENGINEER.
7. 8" CMU WALL SHALL BE GROUTED SOLID IN ALL CELLS. SEE PLAN FOR EXTENTS OF
FULLY GROUTED CMU.
8. INDICATES HANGING BATHROOM PARTITIONS. CONTRACTOR TO COORDINATE
PARTITION LOADING AND LOCATION WITH JOIST MANUFACTURER. REFER TO
DETAIL 06 & 07 ON S500.
Architect of Record:
ADG
800 SW ADAMS STREET, SUITE 101
PEORIA, IL 61602
R e vi si o n s
P - 309.672.6948
Discipline:Discipline:Discipline:
P - P - P -
Discipline:
P -
PROJECT NO.
DATE
DRAWN BY
STATUS
Discipline: Owner Consultant
QSC SERVICES, LLC
PMB #69
545 BRENT LN. PENSACOLA, FL
P - 309.231.8272
OWNER ID:
Design and Construction Administration Division
ESCAMBIA COUNTY, FL
100 E. BLOUNT ST. PENSACOLA, FL 32501
ESCAMBIA COUNTY AREA TRANSIT - FACILITY:
03 - TRANSFER CENTER
41 CLARINDA LN
PENSACOLA, FL, 32505 S200ROOF FRAMING PLAN
KEDbluestone
707 NE JEFFERSON AVE,
PEORIA, IL 61602
RLG CONSULTING ENGINEERS
12001 N CENTRAL EXPY, STE 300
DALLAS, TX 75243
RLG CONSULTING ENGINEERS
12001 N CENTRAL EXPY, STE 300
DALLAS, TX 75243
214.739.8100 214.739.8100 515.727.0700
HODGSON DOUGLAS LANDSCAPE ARCHITECTS
12001 N CENTRAL EXPY, SUITE 1170
DALLAS, TX 75243
214.749.0333
BID PACKAGE #2 - NOT FOR CONSTRUCTION
10/22/2026
RLG
1/8" = 1'-0"01 ROOF FRAMING PLAN
N
A D
D
.1
.1
ADD
T/STL EL
VARIES SEE PLAN
8" CMU WALL REINF -
SEE 11/S300
B/STL EL
107'-4"
FINISH - REF ARCH
6" 18 GA (MIN) @ 16"
OC (MAX) PER CFMF
ENGR
T/PARAPET EL
REF ARCH
VERT BYPASS CLIP
ANGLE PER CFMF ENGR
HSS BEAM (GALV) -
SEE PLAN
STEEL JOIST -
SEE PLAN
METAL ROOF
DECK - SEE
GEN NOTES
HSS 2 1/2X2 1/2X1/4 CONT BTWN JOIST
W/ 1/4" X 8" CONT PLATE. ATTACH DECK
TO PLATE PER PERIMETER
ATTACHMENT PATTERN.
JOIST TAIL EXTENSION - DESIGNER
TO DESIGN TAIL FOR:
DL = 15 PSF ASD
RL = 20 PSF ASD
WL = 46 PSF ASD
L3X3X1/4 CONT
3/16
3/16
3/16
EMBED PL & JOIST
CONNX - SEE 13/S302
3/16
3/16
B/STL EL
107'-4"
8" CMU WALL REINF -
SEE 11/S300
4" CMU SOAP
HSS BEAM (GALV) W/
#4 DBA X 16" -
SEE PLAN
1/4
1/4
S500
6"
8" CMU WALL REINF -
SEE 11/S300
B/STL EL
108'-0"
HSS BEAM (GALV) W/
1/4" CAP PL
5" MIN
2" CMU SOAP
#4 DBA - SEE 02/S500
EMBED PL & BM
CONNX - SEE 15/S302
METAL ROOF DECK -
SEE GEN NOTES
TIE-BACK ANCHOR /
HORIZONTAL LIFELINE
ANCHOR AND
CONNECTION BY
OTHERS
L6X6X3/8 CONT
DRAG STRUT -
ATTACH DECK TO
ANGLE @ 6" OC
CONNECTION BY
MFR
L2X2X1/4 KICKER
WIDE FLANGE W/
3/8" FULL HEIGHT
STIFF PL
3/16
3/16
TYP
3/16
TYP
T/STL EL
VARIES SEE PLAN
8" CMU WALL REINF -
SEE 11/S300
MTL ROOF DECK - SEE
PLAN & GEN NOTES
ATTACH ROOF DECK TO
CONT ANGLE @ 6" OC USING
PIN PER GEN NOTES
3/16
COPE ANGLE ENDS -
SEE 04/S500
WF BEAM - SEE PLAN
L6x6x3/8x1'-4" w/ (2)-5/8" DIA
F1554 GR 36 THREAD RODS
2" 1'-0" 2"
DRILL & EPOXY USING
HILTI-HY 270 SAFESET (5"
EMBED)
REFER TO S302 FOR
ADDL INFORMATION NOT
SHOWN FOR CLARITY
METAL ROOF
DECK - SEE PLAN
PL TO MATCH
THREADED ROD
DIAMETER
3/16
3/16
STEEL JOIST -
SEE PLAN
(2) L3X3X1/4
/2
1/2X4X4 PL
WASHER
NUT T&B OF
(2) L3X3
1/4 PL
3/16
TYP
3/16
3/16
TYP
THREADED ROD FOR
HANGING PARTITION BY
OTHERS - BTWN (2)L3X3
S500
TYPICAL HANGING TOILET
PARTITION SUPPORT DETAIL
FIELD VERIFY
T/STL EL
SEE PLAN
METAL ROOF DECK -
SEE GEN NOTES
L2X2X1/4 STRUT TO
TOP CHORD PANEL
POINT
3/16
TYP
STEEL JOIST -
SEE PLAN
(2) L3X3 FOR TOILET
PARTITION
Architect of Record:
ADG
800 SW ADAMS STREET, SUITE 101
PEORIA, IL 61602
R e vi si o n s
P - 309.672.6948
Discipline:Discipline:Discipline:
P - P - P -
Discipline:
P -
PROJECT NO.
DATE
DRAWN BY
STATUS
Discipline: Owner Consultant
QSC SERVICES, LLC
PMB #69
545 BRENT LN. PENSACOLA, FL
P - 309.231.8272
OWNER ID:
Design and Construction Administration Division
ESCAMBIA COUNTY, FL
100 E. BLOUNT ST. PENSACOLA, FL 32501
ESCAMBIA COUNTY AREA TRANSIT - FACILITY:
03 - TRANSFER CENTER
41 CLARINDA LN
PENSACOLA, FL, 32505 S500FRAMING DETAILS
KEDbluestone
707 NE JEFFERSON AVE,
PEORIA, IL 61602
RLG CONSULTING ENGINEERS
12001 N CENTRAL EXPY, STE 300
DALLAS, TX 75243
RLG CONSULTING ENGINEERS
12001 N CENTRAL EXPY, STE 300
DALLAS, TX 75243
214.739.8100 214.739.8100 515.727.0700
HODGSON DOUGLAS LANDSCAPE ARCHITECTS
12001 N CENTRAL EXPY, SUITE 1170
DALLAS, TX 75243
214.749.0333
BID PACKAGE #2 - NOT FOR CONSTRUCTION
10/22/2026
RLG
A D
D
.1
.1
ADD
WT2
WT1
WT1
WT1
WT2WT1 WT2 WT1
WT2
WT1
WT1
WT2
WT2
WT1
RT1
RT1
RT2
RT2
RT2
WT1
WT2
WT1WT1 WT2 WT1
WT1
WT2
WT1
WT2
WT2
WT1
WT1
WT1WT2
RT1
RT1
RT2
RT2
RT2
WT3
ROOF TYPE (RT) ASSEMBLIES
EXTERIOR WALL TYPE (WT) ASSEMBLIES
7 5/8" GROUND FACE CMU BLOCK.
PROVIDE FULL BED MORTAR JOINTS AND
TOOL ALL JOINTS TO A CONCAVE
PROFILE. (EB1, MT1)
EXTERIORINTERIOR
PROVIDE INJECTED FOAM INSULATION IN ALL NON-
GROUTED CMU CORES AFTER COMPLETION OF
MASONRY GROUTING OPERATIONS. INSULATION
MATERIAL SHALL BE INSTALLED IN ACCORDANCE WITH
MANUFACTURERS REQUIREMENTS AND SHALL COMPLY
WITH FBC ENERGY CONSERVATION CODE SECTION
C402.1.3, EXCEPTION C.
PROVIDE INTEGRAL WATER-REPELLENT ADMIXTURE IN ALL
EXPOSED GROUND-FACE CMU AND MORTAR AS PART OF
A SINGLE-SOURCE MASONRY WATER-REPELLENT SYSTEM.
AFTER MASONRY HAS CURED AND BEEN CLEANED, APPLY
MANUFACTURER'S RECOMMENDED CLEAR BREATHABLE
SILANE/SILOXANE PENETRATING WATER REPELLENT TO
THE EXTERIOR FACE OF THE WALL.
ROOF DECK - SEE STRUC
R-25 ROOF INSULATION BOARD
0'
1/
2" 1'
2"
BAR JOIST - SEE STRUC
ROOF MEMBRANE
1/4" / 12"
5/8" SUBSTRATE BOARD
7 5/8" GROUND FACE CMU BLOCK. PROVIDE FULL
BED MORTAR JOINTS AND TOOL ALL JOINTS TO A
CONCAVE PROFILE (EB4, MT1)
EXTERIORINTERIOR
PROVIDE INJECTED FOAM INSULATION IN ALL NON-
GROUTED CMU CORES AFTER COMPLETION OF MASONRY
GROUTING OPERATIONS. INSULATION MATERIAL SHALL BE
INSTALLED IN ACCORDANCE WITH MANUFACTURERS
REQUIREMENTS AND SHALL COMPLY WITH FBC ENERGY
CONSERVATION CODE SECTION C402.1.3, EXCEPTION C.
7/8'' VENTED HAT CHANNELS
@ 24'' O.C. & AT TOP AND
BOTTOM OF WALL
METAL PANELS W/ CONCEALED
FASTENERS (MP2)
WRB (FLUID APPLIED)
6'' GALVANIZED STEEL STUDS
THICKNESS & SPACING TO DETERMINED
BY COLD FORM ENGINEER
EXTERIORINTERIOR
7/8'' VENTED HAT CHANNELS
@ 24'' O.C. & AT TOP AND
BOTTOM OF WALL
METAL PANELS W/ CONCEALED
FASTENERS (MP2)
WRB (FLUID APPLIED)
5/8'' EXTERIOR GLASS-MAT
GYPSUM SHEATHING
METAL DECK - SEE STRUC
1'' INSULATION
ROOF MEMBRANE
1/2" / 12"
5/8'' ROOF COVER BOARD
A
B
4 5 6 7 8 9321
GWB
8' - 0" A.F.F.
24" x 24" ACT 9' - 0" A.F.F.
24" x 24" ACT 9' - 0" A.F.F.24" x 24" ACT
9' - 0" A.F.F.
24" x 24" ACT 9' - 0" A.F.F.
CUSTOMER SERVICE
C.S. OFFICE
ADA TOILET
JANITOR
VESTIBULE BREAK ROOM
JANITOR
HVAC GWB
8' - 0" A.F.F.
GWB
8' - 0" A.F.F.
SAFE MECH / IT
ADA TOILET
24" x 24" ACT 8' - 6" A.F.F.
NO CEILING
NO CEILING
NO CEILING
NO CEILING
WALL MOUNTED ROOF
ACCESS LADDER & 3'x3'
ROOF HATCH ABOVE
High-Impact Gypsum Board 8' - 0" A.F.F.
High-Impact Gypsum Board 8' - 0" A.F.F.
WOMEN RESTROOM
MEN RESTROOM
0'
7"
0'
7"
1'
4"
PAINT UNDERSIDE OF UPPER CANOPY AND ATTACHED COLUMNS PT3
PT3 PT3 PT3 PT3
PT3PT3PT3PT3
PAINT UNDERSIDE OF LOWER CANOPY AND ATTACHED COLUMNS PT2
PT2PT2
PT2 PT2
PT2 PT2 PT2
PT2PT2PT2
PAINT UNDERSIDE OF LOWER CANOPY AND ATTACHED COLUMNS PT2
Architect of Record:
ADG
800 SW ADAMS STREET, SUITE 101
PEORIA, IL 61602
Re vi sio ns
P - 309.672.6948
Discipline:Discipline:Discipline:
P - P - P -
Discipline:
P -
PROJECT NO.
DATE
DRAWN BY
STATUS
Discipline:Discipline: Owner Consultant
QSC SERVICES, LLC
PMB #69
545 BRENT LN. PENSACOLA, FL
P - 309.231.8272
OWNER ID:
Design and Construction Administration Division
ESCAMBIA COUNTY, FL
100 E. BLOUNT ST. PENSACOLA, FL 32501
ESCAMBIA COUNTY AREA TRANSIT - FACILITY:
03 - TRANSFER CENTER
41 CLARINDA LN
PENSACOLA, FL, 32505 X0013D VIEWS AND WALL / ROOF ASSEMBLIES
KEDbluestone 5518 NW 88th Street, JHONSTON, IA 50131
RLG CONSULTING ENGINEERS
12001 N CENTRAL,
DALLAS, TX 75243
RLG CONSULTING ENGINEERS
12001 N CENTRAL,
DALLAS, TX 75243
214.739.8100 214.739.8100 515.727.0700
HODGSON DOUGLAS LANDSCAPE ARCHITECTS
12001 N. CENTRAL EXPRESSWAY, SUITE 1170
DALLAS, TX 75243
214.749.0333
BID PACKAGE #2 - NOT FOR CONSTRUCTION
11/12/2026 Author
1 3D VIEW, ROOF AND EXTERIOR WALL ASSEMBLIES
2 3D VIEW, ROOF AND EXTERIOR WALL ASSEMBLIES
WT1
AD
D
.1
1.
RT1
WT2
WT3
RT2
1/8" = 1'-0"
9 REFLECTED CEILING PLAN
EB1 ECHELON MASONRY - STANDARD MASONRY - TRENWYTH HIGH POLISH
GROUND FACE BRICK - SIZE: 8" X 12" X 16" - COLOR: 5108 (DARK)
EB2 ECHELON MASONRY - STANDARD MASONRY - TRENWYTH HIGH POLISH
GROUND FACE BRICK - SIZE: 8" X 12" X 16" - COLOR: 5301 (LIGHT)
EB3 ECHELON MASONRY - STANDARD MASONRY - TRENWYTH HIGH POLISH
GROUND FACE BRICK - SIZE: 8" X 8" X 16" - COLOR: 5301 (LIGHT)
EB4 ECHELON MASONRY - STANDARD MASONRY - TRENWYTH HIGH POLISH
GROUND FACE BRICK - SIZE: 8" X 8" X 16" - COLOR: 5301 (DARK)
MP1 MBCI - CONCEALED FASTENING SYSTEM - FW-120-2 PANEL, 24 GAUGE, SMOOTH -
COLOR: BROWNSTONE
MP2 ARMSTRONG WALL & ROOF SYSTEMS - PBU PANEL - COLOR: POLAR WHITE
MT1 SOLOMON COLORS, INC., CONCENTRATED MORTAR - COLOR: 22X TAN
PT2 SHERWIN WILLIAMS - COLOR: QUIETUDE SW6212
PRIME: MACROPOXY 646 FC, 5-10 MILS DFT - TOPCOAT: ACROLON ULTRA, 2-3 MILS DFT
PT3 SHERWIN WILLIAMS - SURF GREEN SW6473
PRIME: MACROPOXY 646 FC, 5-10 MILS DFT - TOPCOAT: ACROLON ULTRA, 2-3 MILS DFT
EXTERIOR FINISH SCHEDULE
ADD
ADD
ADD
NOTE: A 20-YEAR NDL
MEMBRANE WARRANTY IS NOT
REQUIRED AT THIS ROOF TYPE
A
B
4 5 6 7 8 9321
FACE OF FDN TO FACE OF FDN
34' - 8" 12' - 0"
FACE OF FDN TO FACE OF FDN
24' - 0"
FACE OF FDN TO FACE OF FDN
10' - 8"
5'
8"
FA
CE
O
F
FD
N T
O F
AC
E
O F
FD
N
FA
CE
O F
FD
N
T O
F
AC
E O
F
FD
N 2'
8"
FA
CE
O F
FD
N
T O
F
AC
E O
F
FD
N
FA
CE
O F
FD
N
T O
F
AC
E O
F
FD
N 2'
8"
12' - 0"
FACE OF FDN TO FACE OF FDN
72' - 0"
FACE OF FDN TO FACE OF FDN
28' - 0"
FACE OF FDN TO FACE OF FDN
18' - 8"
FACE OF FDN TO FACE OF FDN
25' - 4"
5'
8"
FA
CE
O
F
FD
N T
O F
AC
E
O F
FD
N
FA
CE
O F
FD
N
T O
F
AC
E O
F
FD
N 1'
4"
FA
CE
O F
FD
N
T O
F
AC
E O
F
FD
N
FA
CE
O
F
FD
N T
O F
AC
E
O F
FD
N
1'
4"
CANOPY ROOF LINES
CANOPY ROOF LINES
CA
N
O
PY
R O
O F
LI
N
ES
CA
N
O
PY
R O
O F
LI
N
ES
32' - 0" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 32' - 0"
BASE POINT COORDINATE:
N 538525' 46" E 1105818' 41"
SURVEY POINT COORDINATE:
N 538532' 02" E 1105801' 39"
INTERIOR SLAB ON
GRADE - SEE STRUC
PREFORMED JOINT FILLER W/
SELF LEVELING
POLYURETHANE SEALANT ON
TOP OF PJF
CONTINUOUS FOOTING - SEE
STRUC
FINISHED GRADE - SEE CIVIL
M
IN
0'
1"
ALIGN OUTSIDE FACE OF CMU
WITH FACE OF
FOOTING/FOUNDATION
WT1 WALL TYPE
INTERIOR SLAB ON
GRADE - SEE STRUC
PREFORMED JOINT FILLER W/
SELF LEVELING
POLYURETHANE SEALANT ON
TOP OF PJF
CONTINUOUS FOOTING - SEE
STRUC
FINISHED GRADE - SEE CIVIL
ALIGN OUTSIDE FACE OF CMU
WITH FACE OF
FOOTING/FOUNDATION
WT2 WALL TYPE
J-CHANNEL
PREFINISHED BASE FLASHING -
SEAL TOP EDGE WITH
TERMINATION BAR &
SEALANT AT TOP OF TERM
M
IN
0'
1"
Architect of Record:
ADG
800 SW ADAMS STREET, SUITE 101
PEORIA, IL 61602
Re vi sio ns
P - 309.672.6948
Discipline:Discipline:Discipline:
P - P - P -
Discipline:
P -
PROJECT NO.
DATE
DRAWN BY
STATUS
Discipline:Discipline: Owner Consultant
QSC SERVICES, LLC
PMB #69
545 BRENT LN. PENSACOLA, FL
P - 309.231.8272
OWNER ID:
Design and Construction Administration Division
ESCAMBIA COUNTY, FL
100 E. BLOUNT ST. PENSACOLA, FL 32501
ESCAMBIA COUNTY AREA TRANSIT - FACILITY:
03 - TRANSFER CENTER
41 CLARINDA LN
PENSACOLA, FL, 32505 X002LAYOUT PLAN
KEDbluestone 5518 NW 88th Street, JHONSTON, IA 50131
RLG CONSULTING ENGINEERS
12001 N CENTRAL,
DALLAS, TX 75243
RLG CONSULTING ENGINEERS
12001 N CENTRAL,
DALLAS, TX 75243
214.739.8100 214.739.8100 515.727.0700
HODGSON DOUGLAS LANDSCAPE ARCHITECTS
12001 N. CENTRAL EXPRESSWAY, SUITE 1170
DALLAS, TX 75243
214.749.0333
BID PACKAGE #2 - NOT FOR CONSTRUCTION
11/12/2026 Author
1/8" = 1'-0"
1 FIRST FLOOR LAYOUT PLAN
AD
D
.1
1.
N
1 1/2" = 1'-0"
2 TYP FOUNDATION DETAIL AT WT1
1 1/2" = 1'-0"
3 TYP FOUNDATION DETAIL AT WT2
T.O. SLAB BLDG 2
0' - 0"
4 5 6 7 8 9
T.O. PARAPET BLDG 2
12' - 0"
T.O. PARAPET BLDG 2
12' - 0"
PREFINISHED 8'' x 8'' METAL GUTTERS AND 4'' x 5'' DOWNSPOUTS.
PREFINISHED 8'' x 8'' METAL GUTTERS AND 4'' x 5'' DOWNSPOUTS.
PREFINISHED 8'' x 8'' METAL GUTTERS AND 4'' x 5'' DOWNSPOUTS.
4' - 0" R.O.
GL1
AL1
+14' - 9 1/2"
+12' - 0"
4'
0" R
.O
4' - 0" R.O.
TW
111113
100C
3' - 4" R.O.
3' - 4" R.O. 3' - 4" R.O.
5'
4" R
.O
GL2
A900
X200
T.O. SLAB BLDG 1
1' - 5 1/2"2'
8"
T.O. SLAB BLDG 2
0' - 0"
T.O. PARAPET BLDG 1
14' - 9 1/2"
T.O. LOW CANOPY
18' - 0 1/2"
T.O. HIGH CANOPY
26' - 8"
456789
T.O. PARAPET BLDG 2
12' - 0"
3 2 1
PREFINISHED 8'' x 8'' METAL GUTTERS AND 4'' x 5'' DOWNSPOUTS.
PREFINISHED 8'' x 8'' METAL GUTTERS AND 4'' x 5'' DOWNSPOUTS.
1/2" / 12"
1/2" / 12"
1/2" / 12"
32' - 0" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 32' - 0" 0' - 5"
4' - 0" R.O.
5'
4" R
.O
GL1
AL1
PREFINISHED 8'' x 8'' METAL GUTTERS AND 4'' x 5'' DOWNSPOUTS.
3' - 4" R.O. 4' - 0" R.O.
TW
100A
110 112
3' - 4" R.O.3' - 4" R.O.
GL2
A900
T.O. SLAB BLDG 1
1' - 5 1/2"
7/ 8"
6'
4"
4'
0" R
.O
2'
8"
A B
T.O. PARAPET BLDG 2
12' - 0"
PREFINISHED 8'' x 8'' METAL GUTTERS AND 4'' x 5'' DOWNSPOUTS.
X200
X200
X200
X200
X200
T.O. SLAB BLDG 1
1' - 5 1/2"
T.O. PARAPET BLDG 1
14' - 9 1/2"
AB
T.O. PARAPET BLDG 2
12' - 0"
PREFINISHED 8'' x 8'' METAL GUTTERS AND 4'' x 5'' DOWNSPOUTS.
4' - 0" R.O. 4' - 0" R.O.
5'
8" R
.O
AL1 AL1
GL1 GL1
X200
X200
X200
X112
X200
X200
T.O. SLAB BLDG 1
1' - 5 1/2" T.O. SLAB BLDG 2
0' - 0"
AB
T.O. PARAPET BLDG 2
12' - 0"
X200
X200
T.O. PARAPET BLDG 1
14' - 9 1/2"
A B
TW TW
4' - 0" R.O.
4' - 0" R.O.
10' - 8"
X200
X200
X200
X112
GL2 GL2
X200
T.O. SLAB BLDG 1
1' - 5 1/2"
4'
0" R
.O
GLAZING SCHEDULE
GL1 1" CLEAR INSULATED
GL5 BULLETPROOF GLAZING
ADD
GENERAL ELEVATION NOTES
1.
2.
3.
4.
SEE X001 FOR EXTERIOR WALL TYPE ASSEMBLIES
SEE A900 FOR DOOR DETAILS
SEE X112 FOR WINDOW DETAILS
TICKET WINDOWS: READY ACCESS 4' x 4' TICKET
WINDOW WITH BULLET PROOF GLASS AND DEAL
TRAY
EXT WINDOW SCHEDULE
Architect of Record:
ADG
800 SW ADAMS STREET, SUITE 101
PEORIA, IL 61602
Re vi sio ns
P - 309.672.6948
PROJECT NO.
DATE
DRAWN BY
STATUS
Discipline:Discipline: Owner Consultant
QSC SERVICES, LLC
PMB #69
545 BRENT LN. PENSACOLA, FL
P - 309.231.8272
OWNER ID:
Design and Construction Administration Division
ESCAMBIA COUNTY, FL
100 E. BLOUNT ST. PENSACOLA, FL 32501
ESCAMBIA COUNTY AREA TRANSIT - FACILITY:
03 - TRANSFER CENTER
41 CLARINDA LN
PENSACOLA, FL, 32505 X300EXTERIOR ELEVATIONS
BID PACKAGE #2 - NOT FOR CONSTRUCTION
11/12/2026 Author
1/8" = 1'-0"
6 SOUTH ELEVATION
1/8" = 1'-0"
5 NORTH ELEVATION
1/8" = 1'-0"
1 WEST ELEVATION PUBLIC RESTROOM
1/8" = 1'-0"
2 EAST ELEVATION TICKET BUILDING
1/8" = 1'-0"
3 EAST ELEVATION PUBLIC RESTROOM
1/8" = 1'-0"
4 WEST ELEVATION TICKET BUILDING
AD
D
.1
1.
7 NORTHEAST AERIAL VIEW 8 SOUTHWEST AERIAL VIEW
TYPE MANUFACTURER MODEL NOTES
AL1 KAWNEER IR501T IMPACT STOREFRONT
TW READY ACCESS EXTERIOR TICKET WINDOW
WITH BULLETPROOF GLASS
AND DEAL TRAY
PROVIDE FACTORY-FABRICATED TRANSACTION WINDOW
ASSEMBLY, INCLUDING FRAMING, GLAZING, TRANSACTION
HARDWARE, AND ACCESSORIES. ASSEMBLY SHALL BE
DESIGNED FOR PROJECT-SPECIFIC ASCE 7-22 COMPONENT AND
CLADDING PRESSURES INDICATED ON THE DRAWINGS FOR
VULT = 154 MPH, EXPOSURE C, RISK CATEGORY II. ASSEMBLY
SHALL COMPLY WITH WIND-BORNE DEBRIS REGION
REQUIREMENTS AND BE TESTED IN ACCORDANCE WITH ASTM
E1886 AND ASTM E1996. PROVIDE COMPLETE ASSEMBLY WITH
UL 752 LEVEL 3 BALLISTIC RESISTANCE. THERMALLY BROKEN
FRAMING AND GLAZING SHALL PROVIDE NFRC-CERTIFIED
THERMAL PERFORMANCE OF U-FACTOR ≤ 0.50 AND SHGC ≤
0.25 FOR SOUTH/EAST/WEST EXPOSURES OR ≤ 0.33 FOR
NORTH EXPOSURES. SUBMIT STRUCTURAL, IMPACT, BALLISTIC,
AND THERMAL PERFORMANCE DOCUMENTATION SIGNED AND
SEALED AS REQUIRED BY THE AUTHORITY HAVING
JURISDICTION.
ADD
T.O. PARAPET BLDG 1
14' - 9 1/2"
L.O. HIGH CANOPY
22' - 0"
7 8
100A
T.O. SLAB BLDG 1
1' - 5 1/2"
T.O. SLAB BLDG 2
0' - 0"
T.O. PARAPET BLDG 2
12' - 0"
112 110
186 SF
MEN RESTROOM
39 SF
JANITOR
T.O. PARAPET BLDG 1
14' - 9 1/2"
A B
L.O. HIGH CANOPY
22' - 0"
T.O. PARAPET BLDG 2
12' - 0"
T.O. SLAB BLDG 1
1' - 5 1/2"
A600
T.O. SLAB BLDG 2
0' - 0"
A B
T.O. PARAPET BLDG 2
12' - 0"
BABY CHANGING STATION BABY CHANGING STATION
186 SF
MEN RESTROOM
186 SF
WOMEN RESTROOM
030201
4'
0" 4'
0"
005006 004
3'
0"
F 0' - 6"
2'
6" 1'
8"
2'
36B
07 05
2412001 008
33M 2' - 9"
30B 2' - 6"
42SB
3' - 6"
18DB
1' - 6"
F 0' - 5"
2' - 6" 3' - 6"
1' - 9"
F 0' - 3"
11 11
1'
7' - 3 1/4" 5' - 4 1/4" 7' - 6 7/8"
1' - 4 1/4"
3' - 0"
2'
0" 1'
0"
2'
1"
1'
ADA TOILET
ADA TOILET
A600
06 05
07 07
1'
0"
1' - 4"
3' - 0"
1' - 6"
0'
7"
A6007
BREAK ROOM
5'
9"
24' - 4 3/8"
/8
A600
A600
1'
0" 2'
0"
1' - 6" 1' - 6" 2' - 6"
2' - 7 3/8"
5' - 0" 0' - 1" 3' - 0" 0' - 1" 3' - 0" 0' - 1"
16' - 0 3/8"
9'
3/
8" 6'
3/ 8"
WOMEN RESTROOM
MEN RESTROOM
05 07
04 04 11 05 11 07
3'
0" 2'
0"
1'
0"
2' - 7 3/8"
1'
4"
11 11
HUNG PHENOLIC-CORE TOILET
PARTITIONS. IN SECOND FLOOR,
REFER TO STRUCTURAL DETAIL
DUPLEX RECEPTACLE
QUAD RECEPTACLE
LIGHT SWITCH
OXYGEN OUTLET
VACUUM OUTLET
MED AIR OUTLET
NITROUS OXIDE OUTLET
BOTTLE SLIDE
TELEPHONE / DATA OUTLET
WALL TELEPHONE OUTLET
NURSE CALL
V
A
N
BS
W
LS
NC
SYMBOLS LEGEND
2" TYP.
4'-0'' A.F.F. MAX
PAPER TOWEL
DISPENSER
DOOR
SIGNAGE
SOAP
DISPENSER
TOWEL
BAR
3'-6'' A.F.F. TYP
SANITARY
DISPOSAL UNIT
SINK &
MIRROR
SWITCH COAT
HOOK
CL
3'-4'' A.F.F. MAX
CL
GRAB
BARS
ACCESSIBLE
WATER CLOSET
1'-3'' A.F.F. MIN
TOILET PAPER
DISPENSER
2'-10'' A.F.F. MAX
M
IN
1'
6"CL
EA
R
2'
5"
1'-5" TYP.
16" -18"
" T
YP
. T
O T
/O S
EA
T
8" TYP.
7"-9" at highest operable control
2'-4" A.F.F. TYP
ADA GUIDELINES - TYPICAL MOUNTING HEIGHTS
3' - 4"
1' - 0"
MIRROR DIM. IS TO BOTTOM
OF REFLECTIVE SURFACE
1' - 0"
36" GRAB BAR
42" GRAB BAR
18-24" GRAB BAR
COVER/INSULATE
EXPOSED PIPING
HI
GH
ES
T
RA
IS
ED
C
HA
RA
CT
ER
" T
YP
O R
-6
0" T
O
3'-0'' A.F.F. MAX
3'-5'' A.F.F. MAX
0' - 6" MAX.
PAPER TOWEL
& TRASH UNIT
CHANGING
STATION
T/ O
W O
RK
S
U
RF
AC
E
" A
.F .F
. T O
1'
0" 1'
0"
1'
0" 1'
0"
1'
0" 1'
0"
1'
0" 1'
0"
1'
0"
0' - 0 3/8" 2' - 0" 0' - 0 3/8"
2' - 0 3/4"
4'
0" 4'
0"
1'
0" 1'
3/ 8"
1'
1/
2"
0'
3"
0' - 2 5/8" 0' - 0 3/8"
PL 3/8" X 2 1/2"
PL 3/8"
0'
1/
4"
0' - 3"
1/2" ø 4 1/2"
LAG SCREW
LOCATION OF THE ROOF LADDER FROM THE CORNER STUD
4' - 3 1/4"
0'
7/
8" 0'
3/ 8"
2X WOOD BLOCKING AT
FASTENER LOCATION
0' - 3" 2' - 0 3/4" 0' - 3"
PL 3/8" X 2 1/2"
PL 3/8"
STRUCTURAL SCREWS
THROUGH WOOD BLOCKING
3/4" ROD TYP
0'
7"
0301 02
3'
0" xxxxxxxx xxxxxxxx
STAFF SIDE PUBLIC SIDE
xxxxxxxx xxxxxxxx
TW
xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
Architect of Record:
ADG
800 SW ADAMS STREET, SUITE 101
PEORIA, IL 61602
Re vi sio ns
P - 309.672.6948
Discipline:Discipline:Discipline:
P - P - P -
Discipline:
P -
PROJECT NO.
DATE
DRAWN BY
STATUS
Discipline:Discipline: Owner Consultant
QSC SERVICES, LLC
PMB #69
545 BRENT LN. PENSACOLA, FL
P - 309.231.8272
OWNER ID:
Design and Construction Administration Division
ESCAMBIA COUNTY, FL
100 E. BLOUNT ST. PENSACOLA, FL 32501
ESCAMBIA COUNTY AREA TRANSIT - FACILITY:
03 - TRANSFER CENTER
41 CLARINDA LN
PENSACOLA, FL, 32505 A600LARGE SCALE PLANS
KEDbluestone 5518 NW 88th Street, JHONSTON, IA 50131
RLG CONSULTING ENGINEERS
12001 N CENTRAL,
DALLAS, TX 75243
RLG CONSULTING ENGINEERS
12001 N CENTRAL,
DALLAS, TX 75243
214.739.8100 214.739.8100 515.727.0700
HODGSON DOUGLAS LANDSCAPE ARCHITECTS
12001 N. CENTRAL EXPRESSWAY, SUITE 1170
DALLAS, TX 75243
214.749.0333
BID PACKAGE #2 - NOT FOR CONSTRUCTION
11/12/2026 Author
1/4" = 1'-0"
2 TRANSFER CENTER BLDG SECTION - A
1/4" = 1'-0"
1 TRANSFER CENTER BLDG SECTION B
1/4" = 1'-0"
4 TRANSFER CENTER BLDG SECTION - A1
1/4" = 1'-0"
3 TRANSFER CENTER BLDG SECTION B1
1/4" = 1'-0"
12 PUBLIC RESTROOM - ENLARGED
1/4" = 1'-0"
11 BREAK ROOM - ENLARGED 1/4" = 1'-0"
10 ADA TOILET - ENLARGED
1/4" = 1'-0"
8 MEN RESTROOM ELEV.
1/4" = 1'-0"
9 WOMEN RESTROOM ELEV.
1/4" = 1'-0"
5 ADA TOILET - ELEVATION A
1/4" = 1'-0"
6 BREAKROOM - N. ELEVATION
1/4" = 1'-0"
7 BREAKROOM - W. ELEVATION
AD
D
.1
1.
3/8" = 1'-0"
13 TYPICAL ADA DETAILS & EQUIPMENT MOUNTING HEIGHTS
SEE TYPICAL ADA DETAILS & EQUIPMENT MOUNTING HEIGHTS FOR MOUNTING
HEIGHTS
TOILET ACCESSORY SCHEDULE
MARK DESCRIPTION
01 36" HORIZONTAL GRAB BAR
02 42" HORIZONTAL GRAB BAR
03 18" VERTICAL GRAB BAR
04 TOILET PAPER DISPENSER
05 SOAP DISPENSER
06 SANITARY DISPOSAL UNIT
07 PAPER TOWEL DISPENSER
08 CHANGING STATION
10 Mirror - Frameless - LED Backlight - Plate Glass - Frosted - 36"W X 48"H (0640-4836)
11 Mirror - Stainless Steel Frame - Vandal Proof - 24"W X 36"H
3/4" = 1'-0"
14 JANITOR LADDER
3" = 1'-0"
15 JANITOR LADDER PLATE DETAIL
1" = 1'-0"
17 JANITOR LADDER PLAN
DT1 - MILESTONE TILE - NET-ZERO COLLECTION -
COLOR: IVORY - SIZE: 12"X24" - BRICK INSTALLATION
PATTERN - BRUSHED STAINLESS STEEL L-SHAPE TILE
TRIM ALONG UNFINISHED EDGES. (4'-00" HEIGTH)
PT2 - SHERWIN WILLIAMS - SATIN FINISH
QUIETUDE SW6212 (ACCENT).
1/4" = 1'-0"
18 ADA TOILET ELEV. B
EXPOSED CMU PAINTED WITH PT2 -
SHERWIN WILLIAMS - SATIN FINISH
QUIETUDE SW6212 (ACCENT).
1/4" = 1'-0"
19 BREAKROOM - S. ELEVATION
EXPOSED CMU PAINTED WITH PT-2 -
SHERWIN WILLIAMS - SATIN FINISH
QUIETUDE SW6212 (ACCENT).
DT2 - 23 FULL ROWS, 1/8" GROUT LINE (GT2) -
ALIGN GROUT LINE WITH CENTER OF FAUCET -
BRUSHED STAINLESS STEEL L-SHAPED TILE TRIM
ON UNFINISHED EDGES.
25" DEEP SOLID SURFACE (SSM2) MATERIAL
W/ 4" BACKSPLASH.
42" STAINLESS STEEL DOUBLE BOWL
DROP-IN SINK.
ALL BASE AND WALL CABINETS, PL2
25" DEEP SOLID SURFACE (SSM2) MATERIAL
W/ 4" BACKSPLASH - WORK SURFACE SUPPORT
@ 2'-10" MAX.
PT-2 - SHERWIN WILLIAMS - SATIN FINISH
QUIETUDE SW6212 (ACCENT).
24" DEEP PARTICLE BOARD COUNTER
TOP WITH PLASTIC LAMINATE (PL1) -
WORK SURFACE SUPPORT @3'00" MAX.
CASEWORK LEGEND
B BASE
DB DRAWER BASE
TB TRASH BASE
SB SINK BASE
TM TALL MICROWAVE
1/2" = 1'-0"
20 TRANSFER CENTER BLDG - TICKET WINDOW COUNTER
ADD
ADD
ADD
ADD
ADD
DO
O
R
SI
ZE
DOOR SIZE
FFT1
aa a
DOOR SIZE
DO
O
R
SI
ZE
HOLLOW METAL FRAME FLUSH
FT2
aa b
DOOR SIZE
DO
O
R
SI
ZE
HOLLOW METAL FRAME
0' - 2"
7/
8"
O
VE
RA
LL
W
AL
L
DE
PT
H
HOLLOW METAL
FRAME SECTION
a
0' - 4"
7/
8"
O
VE
RA
LL
W
AL
L
DE
PT
H
HOLLOW METAL
FRAME SECTION
b
HM HOLLOW METAL
F FLUSH
ABBREVIATIONS
GENERAL DOOR SCHEDULE NOTES
1.
2.
SEE A115 FOR FINISHES
SEE X300 FOR EXTERIOR ELEVATIONS
GLAZING SCHEDULE
GL1 1" INSULATED GLAZING UNIT
GL2 NOT USED
GL3 NOT USED
GL4 1/4" TEMPERED
MINIMUM (4) ANCHORS PER
JAMB
(2) 18 GAUGE STEEL STUDS, EXTEND
AND SECURE TO METAL
DECK ABOVE
CAULK
16 GAUGE HOLLOW
METAL FRAME
FOR WALL TYPE, SEE
X001
COILING DOOR MOUNTED
TO BACKSIDE OF WALL
ABOVE / BOTTOM OF BEAM
COILING DOOR JAMB BY MFR,
W/ WEATHERSTRIPPING
ANGLE ORIENTATION AS
SHOWN, TO HIDE FASTENERS
FROM VIEW. ANGLES TO BE
FACTORY PAINTED THE SAME
COLOR AS THE COILING DOOR
CURTAIN
HOLLOW METAL DOOR FRAME -
ALIGN OUTSIDE EDGE OF PRAME
WITH OUTSIDE FACE OF CMU
WALL
SHIM AS REQUIRED
BACKER ROD & SEALANT
BACKER ROD & SEALANT
OUTSIDE
HOLLOW METAL DOOR FRAME.
ALIGN OUTSIDE OF FRAME WITH
FACE OF CMU WALL
SHIM AS REQUIRED
BACKER ROD & SEALANT -
BOTH SIDES
12" CMU LINTEL W/
REINFORECEMT - SEE STRUC. OUTSIDE
AL
IG
N
WT2
HOLLOW METAL DOOR FRAME -
ALIGN OUTSIDE EDGE OF PRAME
WITH OUTSIDE FACE OF CMU
WALL
SHIM AS REQUIRED
BACKER ROD & SEALANT
BACKER ROD & SEALANT
OUTSIDE
NOTES
CARD READER: CR
DOOR CONTACT: DC
REQUEST EXIT (PIR): REXIT-PIR
ELECTRIC STRIKE: ES
LOCKDOWN: LD#
DOOR SWITCH: DS#
Architect of Record:
ADG
800 SW ADAMS STREET, SUITE 101
PEORIA, IL 61602
Re vi sio ns
P - 309.672.6948
Discipline:Discipline:Discipline:
P - P - P -
Discipline:
P -
PROJECT NO.
DATE
DRAWN BY
STATUS
Discipline:Discipline: Owner Consultant
QSC SERVICES, LLC
PMB #69
545 BRENT LN. PENSACOLA, FL
P - 309.231.8272
OWNER ID:
Desig…
This is the start of the file's text. The full file is on GovTribe.