EAGLE_SPRINGS_MAINTENANCE_BLDG_Arch_Plans.pdf
PDF 20 MB Posted
- Attached to
- ESGC Phase One Maintenance Building
- Solicitation number
- 25-19
- Issued by
- Walton County, Florida
About this file
This file consists of architectural and engineering plans for the Eagle Springs Golf Course Maintenance Building project in Walton County, Florida, prepared by Russell Johnson Architect and Atlas Engineering and Consulting. The project involves construction of a single-story, 9,600 square foot pre-engineered metal building (PEMB) designed to serve as equipment storage and office space for the golf course maintenance operations in DeFuniak Springs. The building accommodates 39 total occupants across 1,920 square feet of business space (office areas) and 7,680 square feet of storage space, with designated exits, life safety provisions, restrooms, mechanical rooms, and break room facilities. The design complies with the 2023 Florida Building Code and NFPA standards, incorporating Type VB non-combustible construction with a two-hour occupancy separation between the business and storage areas. The contract timeline extends 120 days for substantial completion with an additional 30 days for punch list completion, with a mandatory pre-bid meeting scheduled for July 8, 2025, at 8:30 am and bid responses due July 30, 2025, at 3:00 pm.
The project's total estimated cost is $3,283,497.67, comprised of a base bid of $1,624,045.09 for building materials, construction, utility hookups, and site grading; Alternate 1 interior build-out at $805,000.00; Alternate 2 access and parking lot paving at $682,853.32; and Alternate 3 sewer lift station at $171,599.26, with 15% contingency included for each alternate. The project will be funded through Walton County resources and constructed on a 24,970 square foot site in DeFuniak Springs. The facility includes impact-rated exterior doors and windows, HVAC systems with heat pump split systems and high-volume low-speed fans, comprehensive plumbing and electrical infrastructure, sealed concrete flooring in storage areas, and provisions for future fire sprinkler systems. The selected contractor must be a licensed, insured General Contractor compliant with Walton County Ordinance 2009-01 and must obtain a county building permit. Bidders must submit a 5% bid security along with local preference applications, drug-free workplace certifications, and proof of licenses; the county will award the contract to the lowest, most responsible and responsive bidder meeting project specifications.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A R
C H
IT
EC
TU
E r a ja r c h@ m sn
.c o m
R
US
S E
LL
J O H N S O N
C H
IT
E C T
P L
A - 100
PERFORMANCE STANDARDS
OUTSIDE DIAMETER
ON CENTER(S)OC
OD
GENERAL NOTES
FE
FDNAT
ACT
ACOUSTICAL TILEPLYWOODEARTH
MATERIAL SYMBOLS ABBREVIATIONS
FIRE EXTINGUISHER
FOUNDATION
SYMBOL LEGEND
SHOP DRAWINGS
EAGLE SPRINGS GOLF COURSE
NOTE:
RISER/RADIUS
ROOF DRAIN
CONTRACTOR ROUGH IN
OWNER FURNISHED
OWNER INSTALLED
OWNER FURNISHED
PLASTIC LAMINATE
PRESSURE TREATED
QUARRY TILE
OPPOSITE HAND
PAIR
OPPOSITE
PLATE
OVERHEAD
RD
R
OPH
QT
PT
PR
PL
OPP
OH
OFOI
PLAM
OFCRI
REVISE(SION)(D)
ROUGH OPENING
STAINLESS STEEL
SPECIFICATION(S)
SOLID CORE
STRUCTURAL
REINFORCE(D)(ING)
SYSTEM
ROOM
SIMILAR
SECTION
SQUARE
SOUTH
REQUIRED
RESILIENT
RECESSED
SS
SYS
RM
SQ
SIM
SECT
SC
S
RO
RES
REV
REQ
REC
STRUCT
SPEC
REINF
CONTRACTOR INSTALLED
THICK(NESS)
VINYL WALL COVERING
VENT THRU ROOF
WEST/WIDTH
WORK POINT
WITH
WITHOUT
VERTICAL
UNDERCUT
TOP OF
TYPICAL
W/
WPT
W/0
W
VCT
VTR
VWC
VERT
UON
UC
UL
TYP
TO
THK
UNDERWRITERS LABORATORY
UNLESS OTHERWISE NOTED
VINYL COMPOSITION TILE
T TREAD
HDW
HM
FTG
GWB
HA
GYP
GALV
GA
GL
FIXT
FO
FT
FL
FHC
FIN
FF
BRICKBRK
BUR
CEM PL
BOARD
BITUMINOUS
BUILDING
BLOCK
BLOCKING
BEAM
BOTTOM
BEARING
BLK
BLKG
BOT
BRG
BM
BLDG
BIT
BD
APPROXIMATE
AHU
APPROX
ARCH
AFF
AE
BUILT UP ROOFING
CEMENT PLASTER
ARCHITECT-ENGINEER
ABOVE FINISHED FLOOR
AIR HANDLING UNIT
ARCHITECT(URAL)
HOUR
HVAC
HR
HT
MAX
LF
LAV
INSUL
INT
L
JT
IN
ID
JOINT
INCH
CT CERAMIC TILE
DETAIL
DEMO
DF
DET
CEILING
COLUMN
CONCRETE
CONTINUE(OUS)
CARPET(ED)
CONFERENCE
CENTER LINE
CONC
CONT
CPT
CONF
CMU
COL
CLG
CL
CHEMICAL
CFCI
CHEM
CJ
CONSTRUCTION JOINT
DRINKING FOUNTAIN
CONCRETE MASONRY UNIT
DEMOLISH(TION)
CONTRACTOR INSTALLED
CONTRACTOR FURNISHED
CONTROL JOINT/
BATT INSULATION
LATH
GWB/PLASTER/
STUCCO/GROUT
ACOUSTICAL OR
CERAMIC TILE
RIGID INSULATION
FIRE SAFING/
COMP FILLER
SCALE: 1"=1'-0"
DETAIL
BIT DAMPROOFING
BUILDING SECTION
DETAIL TITLE
NO
NTS
NOM
NIC
NA
N
MFR
MISC
MIN
MET
DR DOOR
EQUAL
EXISTING
EXPOSED
EQUIPMENT
EXP
EWC
EXIST
EQUIP
EQ
EAST
EACH
ELEVATION
ELECTRIC(AL)
ELEVATOR
DRAWING(S)
EA
ELEC
ELEV
EL
EJ
DWG
E
DIMENSION
DIVISION
DOWN
DIV
DN
DIM
ELECTRIC WATER COOLER
EXPANSION JOINT
EXTERIOREXT
INTERIOR
ELEVATION
FINISH FLOOR
ELEVATION
COLUMN REFERENCE
AND GRID LINES
2 A
12'-4"
SECTION CUTS
DIAMETERDIA MECH
ROUGH WOOD
(CONTINUOUS)
MASONRY UNIT
FINISHED WOOD
BRICK
CONCRETE
CONCRETE
GRANULAR FILL
A5.1
SHEET REFERENCE
SECTION NUMBER
A8.1
SHEET REFERENCE
DETAIL NUMBER
(NOT CONTINUOUS)
ROUGH WOOD
DOOR MARK
A9.1
SHEET REFERENCE
SECTION NUMBER
W3
B
NUMB
NAME ROOM NAME
WALL TYPE MARK
WINDOW MARK
ROOM NUMBER
GENERAL SYMBOLS
HARDWARE
HEATING, VENTILATING AND
HEIGHT/HIGH
AIR CONDITIONING
HOLLOW METAL
FIRE HOSE CABINET
GYPSUM WALL BOARD
HANDICAP ACCESSIBLE
FOOTING
GAGE/GAUGE
GALVANIZED
GLASS/GLAZING
GYPSUM
FINISHED FLOOR
FINISH(ED)
FIXTURE
FACE OF
FOOT/FEET
FLOOR
NOT TO SCALE
NOT IN CONTRACT
NOT APPLICABLE
MISCELLANEOUS
MANUFACTURE(R)
MECHANIC(AL)
LINEAL FEET
INSULATE(D)(ION)
INSIDE DIAMETER
NUMBER
NOMINAL
NORTH
METAL
MINIMUM
MAXIMUM
LAVATORY
INTERIOR
LENGTH
1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CODES
REFERENCED IN THESE DOCUMENTS AND AS ADPOTED AND
SUPPLEMENTED BY LOCAL REGULATIONS.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ACQUIRING
ALL BUILDING PERMITS FROM THE LOCAL BUILDING
DEPARTMENTS AS REQUIRED BY CITY/COUNTY REGULATIONS.
FEES FOR SUCH PERMITS SHALL BE PAID BY THE
CONTRACTOR AND A SET OF APPROVED DRAWINGS AND
ORIGINAL PERMITS SHALL BE RETAINED ON SITE FOR THE
DURATION OF THE PROJECT.
3. THE DESIGN INFORMATION SHOWN ON THE DRAWINGS
PROVIDES OVERALL DIMENSIONAL PARAMETERS AND
DESCRIBES ELEMENTS TO BE CONSTRUCTED. THE
CONTRACTOR SHALL ADJUST DIMENSIONS AND DETAILS AS
REQUIRED TO FIT EXISTING CONDITIONS. THE
ARCHITECT/ENGINEER SHALL BE NOTIFIED OF ALL PROPOSED
MODIFICATIONS.
4. NO CHANGES TO THE INFORMATION SHOWN ON THE
DRAWINGS SHALL BE MADE WITHOUT THE SPECIFIC WRITTEN
APPROVAL OF THE ARCHITECT OR ENGINEER, AS
APPICABLE.
5. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY
DISCREPANCIES ON THESE DOCUMENTS.
6. ALL EXTERIOR COMPONENTS SHALL HAVE FLORIDA
APPROVAL NUMBERS.
7. EXTERIOR GLAZING SHALL BE IMPACT RATED when required by the local ahj.
8. exterior doors shall be impact rated when required by the local ahj.
9. FIRE SPINKLER / FIRE ALARM if required shall be DESIGNed BY OTHERS AS REQUIRED TO MEET FBC 2020, NFPA, & FLORIDA FIRE PREVENTION CODE when required by the local ahj.
COPIES OF ALL SHOP DRAWINGS FOR STRUCTURAL OR LIFE
SAFETY RELATED COMPONENTS SHALL BE SUBMITTED TO THE
ARCHITECT & OWNER FOR APPROVAL..
THE CONTRACTOR SHALL SUBMIT DETAILED FABRICATION AND
INSTALLATION DRAWINGS AND PRODUCT LITERATURE FOR THE
FOLLOWING ITEMS. ARCHITECT REVIEW OF SHOP DRAWING IS FOR
COMPLIANCE OF THE PRODUCT WITH THE DESIGN CONCEPTS
DELINEATED IN THESE DOCUMENTS. THE CONTRACTOR AND/OR
PRODUCT MANUFACTURER SHALL BE RESPONSIBLE FOR THE
ACCURACY AND PERFORMANCE OF THE PRODUCT AND ITS
COORDINATION WITH THE OTHER TRADES.
1. STRUCTURAL STEEL
2. METAL STUD FRAMING
3. ROOF TRUSSES, LVL, & PRE-ENGINEERED BEAMS
4. REINFORCING STEEL
5. CONCRETE DESIGN MIXES
6. WATERPROOF MEMBRANES
7. RAILINGS & HANDRAILS
8. ARCHITECTURAL PRE-CAST OR PRE-FORMED COLUMNS
9. APPLIED FOAM TRIM, WINDOW/DOOR HEADS, AND
ARCHITECTURAL DETAILING
10. BATHROOM ACCESSOIRES & MIRRORS
11. ALL FOOR, WALL , AND CEILING FINISHES
12. ALL CABINETRY
13. ELEVATORS
14. STAIRS AND HANDRAILS
15. ALL HEATING & VENTILATING EQUIPMENT
16. ELECTRICAL FIXTURES & EQUIPMENT
17. ALL PLUBMING FIXTURES
18. DOORS, WINDOWS, AND ALL HARDWARE
19. FIREPLACES
20. APPLIANCES
ALL MATERIALS, PRODUCTS AND THEIR INSTALLAITON SHALL MEET THE
PRODUCT APPROVAL OF AND BE INSTALLED IN ACCORDANCE WITH THE
STANDARDS ESTABLISHED BY THE FOLLOWING AGENCIES, AS APPICALBE:
ASTM AMERCIAN SOCIETY OF TESTING MATERIALS
ACI - AMERICAN CONCRETE INSTITUE
AF&PA - AMERICAN FOREST & PAPER ASSSOCIATION
AISC - AMERICAN INSTITURE OF STEEL CONSTRUCTION
AWI - AMERICAN WOODWORK INSTITUTE
AWPB - AMERICAN WOOD PERSERVATIVES BUREAU
ANSI - AMERICAN NATIONAL STANDARDS INSTITUTE
AAMA - ARCHITECTURAL ALUMINUM MANUFACTURE'RS ASSOCIATION
FBC - FLORIDA BUILDING CODE
GA - GYPSUM ASSOCIATION
LSC - LIFE SAFETY CODE
NER - NATIONAL EVALUATION SERVICE INC
NFPA - NATIONAL FIRE RPOTECTION ASSOCIATION
NDW - NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION
OSHA - OCCKUPATIONAL SAFETY AND HEALTH ACT
SJI - STEEL JOIST INSTITUE
TCA - TILE COUNCIL OF AMERICA
UL - UNERWRITERS LABORATORIES
FIRE EXTINGUISHER CABINETFEC OWNER FURNISHEDOFCIAREA DRAINAD
ARCHITECT NOT RESPSONIBLE FOR ANY CIVIL WORK, SITE WORK,
LANDSCAPE DESIGN, FIRE SUPPRESSION SYSTEMS, OR ANY
OTHER WORK NOT SPECIFICALLY ADDRESSED BY THESE
DOCUMENTS.
BIDDING DOCUMENTS
11.17.23
METAL BUILDING - EQUIPMENT STORAGE AND OFFICE SPACE
WALTON COUNTY FLORIDA
TOTAL SF = 9.600 SF
e a g le s p r in g s g o lf c o u r s e m a in t e n a n c e b u il d in g w a lt o n c o u n t y f lo r id a
MAINTENANCE BUILDING
BUILDING DESIGN DATA
APPLICABLE CODES
INDEX OF DRAWINGS
MAIN BUILDING
A100 COVER
A101 LIFE SAFETY PLAN
A101.5 FLOOR PLAN
A102 ELEVATIONS
A103 ELEVATIONS
A104 BUILDING SECTION
A105 ENLARGED BATHROOMS
STRUCTURAL DRAWINGS
S001 SPECIFICATIONS / NOTES
S101 FOUNDATION PLAN
S501 DETAILS
MECHANICAL / PLUMBING
M001 SCHEDULES
M100 HVAC PLAN
M101 HVAC DETAILS
M102 HVAC DETAILS
P001 NOTES AND DETAILS
P100 BELOW FLOOR SANITARY
P101 ABOVE FLOOR PLUMBING PLAN
P102 PARTIAL PLUMBING PLAN
P103 SANITARY SEWER RISER
ELECTRICAL ENGINEERING
E100 ELECTRICAL NOTES
E101 NOTES
E1002 ELECTRICAL PLANS
2023 florida building code, building, 8th edition 2023 florida building code, accessibility, 8th edition 2023 florida building code, energy conservation, 8th edition 2023 florida building code, plumbing, 8th edition 2023 florida building code, mechanical, 8th edtion, 2023 florida builidng code, fuel gas, 8th edition florida fire prevention code national electrical code 2017 nfpa 101 life safety code 2020 w/ amendments florida statutes florida administrative code refer to other drawings for other applicable codes
PROJECT DATA
RUSSELL JOHNSON, ARCHITECT
P.O. BOX 1399
(850) 630.4483
AR 0012593
PANAMA CITY, FL. 32401
ATLAS ENGINEERING AND CONSULTING
455 HARRISON AVE, SUITE B
(850) 257.5316
PANAMA CITY, FL
rajarch@msn.com
INFO@ATLASENGINEERINGFL.COM
WELCON ELECTRICAL CONSULTANTS , PLLC
14116 CUSTOMS BLVD, SUITE #111
(228).822.8000
GULFPORT, MS 39503
STEPHENS MECHANICAL ENG, LLC
925 TOMMY MUNRO DR
BILOXI, MS 39532
SUITE B
(228) 207-3322
REGISTRY NO. 34399
NOTE:
THIS PROJECT IS A PRE-MANUFACTURED METAL BUILDING
(PEMB). THE PEMB MANUFACTURER IS RESPONSIBLE FOR ALL
STRUCTURAL DESIGN ELEMENTS INCLUDING WIND LOADING AND
LATERAL BRACING, WALL AND ROOF FRAMING, ALL FRAMING
ELEMENTS FOR WINDOW AND DOOR OPENINGS, INCLUDING THE
OVERHEAD DOORS ETC. REFER TO STRUCTURAL DOCUMENTS
FOR FOUNDATION DESIGN. THE PEMB SUPPLIER SHALL SUBMIT
FULL SHOP DRAWINGS FOR REVIEW AND APPROVAL BY THE
STRUCTURAL ENGINEER, ARCHITECT, AND THE LOCAL AHJ'S.
these shop drawings shall include all reactions and design pressures for exterior components. THESE SHOP
DRAWINGS SHALL BE SIGNED AND SEALED BY AN ENGINEER
REGISTERED IN THE STATE OF FLORIDA.
PROJECT DATA:
1 story building -business / storage s2 separated occupancy level one: 9,600 sf (21,920 sf heated & cooled) occupancy type occupant load business 1,920 sf b 1,920 sf / 150 sf gross = 13 occupants storage s2 7,680 sf s2 storage 7,680 sf / 300 sf gross = 26 occupants total occupant load level one = 39 occupants
MINIMUM EGRESS CAPACITY FOR OCCUPANT LOAD = LEVEL ONE (horizontal) = 39 OCC X .2 (SP) = 8" required, 192" PROVIDED
MINIMUM NO. OF EXITS = 2 EXITS REQUIRED, 6 EXITS PROVIDED
COMMON MEANS OF EGRESS TRAVEL DISTANCE = 75 FT. (TABLE 1006.2.1)
ALLOWABLE TRAVEL DISTANCE TO AN EXIT = 300 FT (TABLE 1017.2) ACTUAL TRAVEL DISTANCE = 126 FT
TYPE OF CONSTRUCTION = TYPE vb, NON-COMBUSTIBLE MAX ALLOWABLE NO. OF STORIES = 2 (ACTUAL = 1) - SECTION 510.6 FBC BUILDING CODE 2020 MAX ALLOWABLE SF PER FLOOR = s2 = 13,500 sf allowed, 7,680 sf actual provide.
b = 9,000 allowed, actual sf = 1,920 actual sf (PER 506.2.3) occupancy separation - b to s2 = 2 hours per fbc 508.4 exterior walls fire rating - 0 hr required per table 602 fire separation distance > 30 = 0
PRIMARY STRUCTURAL FRAME = 0 HR REQUIRED, 0 HR PROVIDED
BEARING WALLS - EXTERIOR AND INTERIOR = 0 HR REQUIRED, 0 HR PROVIDED
NON BEARING INTERIOR WALLS - 0 HR REQUIRED, 0 HR PROVIDED
ROOF CONSTRUCTION AND SECONDARY MEMBERS - 0 HR REQUIRED, 0 HR PROVIDED (ROOF)
0 HR PROVIDED (MEMBERS)
interior walls shall be continuous from floor slab to underside of floor deck or roof deck above.
PROVIDE EXIT SIGNAGE AND DIRECTIONAL SIGNAGE PER NFPA 101
PROVIDE PORTABLE FIRE EXTINGUISHERS PER NFPA - see note this drawing below.
MEN
WOMEN
120'-0" equipment storage supervisor assistant break ROOM mechanic grinder & office parts ROOM office office
120'-0" foyer
A R
C H
IT
EC
TU
ja r c h@ m sn
.c o m
R
US
S E
LL
J O H N S O N
A
R C H
IT
E C T
P L
A - 101 e a g le s p r in g s g o lf c o u r s e
FLOOR PLAN
SCALE: 3/16" = 1'-0"
m a in t e n a n c e b u il d in g w a lt o n c o u n t y f lo r id a
D1 W1 D2 D1D2W1 W1
W1
D2
D2
W1
D1
D1
D1
W1W1W1W1W1W1
W1
D1
D2
D2
D3 D3 D3 D3 D3
D4
D4
D5 D5 D5 D6
D6
D4
D7 bathroom restroom restroom bathroom bathroom closet
UL 419 2 HRUL 419 2 HRUL 419 2 HR UL 419 2 HRUL 419 2 HRUL 419 2 HR
36 X 36
ADA SHWR
36 X 36
ADA SHWR
mechanical
UL 419 2 HR
D3
D8
REFRIG
SINK
ICE
MACHINEMW
indicates 2 hr wall assembly ul 419 or approved equal ada threshold ada threshold ada threshold ada thresholdada threshold ada threshold steel frame by pemb -typical all locations
DESIGNATED EXITS
fire extinguisher note: fire extinguisher types, sizes, and locations shall be in compliance w/ applicable codes and as approved by the authority having jurisdiction. provide complete submittal for approval by the ahj.
LIFE SAFETY PLAN
W1 a104
MEN
WOMEN
120'-0" equipment storage supervisor assistant break ROOM mechanic grinder & office parts ROOM office office
24'-0" 24'-0" 24'-0" 24'-0" 24'-0"
120'-0"
17'-0" 8'-4"
16'-0" 22'-11" 7'-6" 11'-11" 17'-4" foyer
A R
C H
IT
EC
TU
ja r c h@ m sn
.c o m
R
US
S E
LL
J O H N S O N
A
R C H
IT
E C T
P L
A - 101.5 e a g le s p r in g s g o lf c o u r s e
FLOOR PLAN
SCALE: 3/16" = 1'-0"
m a in t e n a n c e b u il d in g w a lt o n c o u n t y f lo r id a
D1 W1 D2 D1D2W1 W1
W1
D2
D2
W1
D1
D1D1 W1W1W1W1W1W1
W1
D1
W1
D2
D2
12'-0" 7'-4" 16'-8" 22'-0" 3'-6" 12'-10" 25'-6" 8'-2" 12'-0"
7'-6" 4'-6" 24'-0" 24'-0" 24'-0" 24'-0" 4'-6" 7'-6"
D3 D3 D3 D3 D3
D4
D4
D5 D5 D5
D5
D6
D6
D4
D7 bathroom restroom restroom bathroom bathroom closet
2'-2"
5' -1
1" 2' -4
/8
7' -8
/4
2'-2"
7'-9"
2'-6"
5' -9
/2
3' -9
/4
/4
UL 419 2 HRUL 419 2 HRUL 419 2 HR UL 419 2 HRUL 419 2 HRUL 419 2 HR
7' -6
/8
7/
7' -4
5/
1/
36 X 36
ADA SHWR
36 X 36
ADA SHWR
ADA DF
mechanical
2'-4 3/4" 7'-9"
8'-9 3/4"
UL 419 2 HR
D3
D8
REFRIG
SINK
ICE
MACHINEMW
indicates 2 hr wall assembly ul 419 or approved equal ada threshold ada threshold ada threshold ada thresholdada threshold ada threshold mop sink - provide s.s. mop and broom wall mounted holders cl of door /window typical steel frame by pemb -typical all locations interior walls to be 3 5/8" metal studs @ 16" oc w/ 5/8" painted gyp bd each side. stud ga and blocking per manufacturer's requirements.
provide 3" batt insulation for bathrooms and mechanical spaces. provide r19 wall insulation in 2 hr ul 419 assembly note: provide gyp board and metal framed steel column enclosure at the office, breakroom, restroom areas a104
C H
IT
EC
TU
ja r c h@ m sn
.c o m
R
US
S E
LL
J O H N S O N
A
R C H
IT
E C T
P L
A - 102 e a g le s p r in g s g o lf c o u r s e elevations
SCALE: 3/16" = 1'-0"
m a in t e n a n c e b u il d in g w a lt o n c o u n t y f lo r id a
GUTTER, DOWNSPOUT - WHITE, & CONC. SPLASHBLOCK
front elevation right side elevation
METAL ROOF PANELS BY PEMB, LIGHT GREY COLORC
A PEMB METAL WALL PANELS - LIGHT GREY COLOR
C
GUTTER WHITEG
GGGGGG
G
D1
D2
D3
D4
D5
D6
D7
D8
METAL ROOF PANELS BY PEMB, LIGHT GREY COLOR
METAL ROOF PANELS BY PEMB, LIGHT GREY COLORC
GUTTER WHITE
GUTTER, DOWNSPOUT - WHITE, & CONC. SPLASHBLOCKG
Q Q
METAL ROOF FASCIA BY PEMB, WHITE
METAL ROOF FASCIA BY PEMB, WHITE
METAL DOOR & TRIM - WHITE, TYPICAL
WINDOW TRIM - WHITE, TYPICAL
OH DOOR & TRIM - WHITE, TYPICAL
METAL ROOF FASCIA BY PEMB, WHITE
3.75
1.63
LEGEND
PEMB METAL WALL PANELS - LIGHT GREY COLOR
STEEL PEMB FRAME
METAL ROOF PANELS
ROOF FASCIA BY PEMB, WHITE
PEMB Z-GIRTS
IN COMPLIANCE W/ FBC ENERGY CODE -
GUTTER, DOWNSPOUT, & CONC. SPLASHBLOCK
WINDOW OR DOOR - WHITE TRIM
CEILING - 5/8" TYPE X PAINTED GYP BD, COORDINATE W/ OWNER
CONCRETE FOUNDATION - REFER TO STRUCTURAL
3-5/8" METAL STUDS (6" @ PLUMBING WALLS IF REQUIRED)
CONCRETE FLOOR SLAB - REFER TO STRUCTURAL, PROVIDE VAPOR BARRIER
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
@ 16" OC W/ 5/8" TYPE X PAINTED GYP BD
SHOP DRAWINGS FROM THE METAL STUD MANUFACTURER
METAL STUD GAUGE, BRACING, ETC SHALL BE PER SIGNED AND SEALED
8 FT H METAL PANELS BY PEMB IN STORAGE AREA
2 HOUR WALL ASSEMBLY
R
WALL INSULATION W/ VAPOR RETARDER -
PROVIDE 3.5" BATT INSULATION ALL INTERIOR WALLS THAT ABUTT THE
MAIN STORAGE AREA AND ALL MECHANICAL AND BATHROOMS.
ON 6" 18 GA CEILING JOISTS @ 16" OC.
IN COMPLIANCE W/ FBC ENERGY CODE -
ROOF INSULATION W/ VAPOR RETARDER -
PROVIDE 2 HOUR WALL ASSEMBLY WHERE INDICATED ON PLAN
PROVIDE UL APPROVED FIRE CAULKING SYSTEM MATCHING FIRE RATING
OF WALL @ STEEL BEAM PENETRATIONS
LOUVERS - COORDINATE W/ MECHANICAL DRAWINGS
TYPICAL ALL SPACES EXCEPT MAIN STORAGE AREA
PROVIDE UL APPROVED 2HR ASSEMBLY UL I 506 OR APPROVED EQUAL
(2) LAYERS 5/8" TYPE ULIX GYP BD, LOOSELY LAID ON TOP OF MIN 6" D
STEEL JOISTS @16" OC AND (3) LAYERS TYPE ULIX GYP BD ATTACHED
TO THE BOTTOM OF THE STEEL CEILING JOISTS.
BASE - EQUAL TO MERCER 1/8" 4" VINYL COVE BASE - FROM STANDARD COLORS
INTERIOR WALLS -
OFFICES / BREAK ROOMS / RESTROOMS ETC. PAINTED GYP BD, MOISTURE
RESISTANT GYP BD IN RESTROOMS. PROVIDE PRIME COAT, (2) COATS OF FINISH,
COLOR PER OWNER, EPOXY PAINT IN RESTROOMS, MECH SPACES, AND SURFACES
EXPOSED TO STORAGE AREA REQUIRING PAINTING.
STORAGE AREA - 8 FT HIGH METAL PANELS BY PEMB MANUFACTURER -
EXPOSED METAL STRUCTURAL AND OTHER FRAMES TO BE PAINTED AFTER
REMOVING ALL RUST - USE PRIMER AND PAINT DESIGNED FOR METAL - SUBMIT
PAINT TO OWNER FOR APPROVAL
INTERIOR DOOR FRAMES TO RECEIVE TNEMEC "GRAY COURT" #GR22 OR APPROVED EQUAL
STORAGE AREA FLOORS - SEALED CONCRETE W/ A NON-SLIP FINISH - BASIS OF
DESIGN SHALL BE TS210 BY "CONCRETE SEALERS USA" OR AN APPROVED
EQUAL. INSTALL AND FINISH CONCRETE SURFACE PER MANUFACTURER'S
SPECIFICATIONS.
(REFER TO ROOM FINISH NOTES)
CEILINGS - PAINTED GYP BD, 1 COAT PRIMER 2 COATS FINISH - USE EPOXY
PAINT ON MOISTURE RESISTANT GYP BD IN RESTROOMS. (EXCEPT
STORAGE AREA)
FINISH SCHEDULE
NOTE: FINISHES SHALL BE COORDINATED WITH OWNER
PRIOR TO PURCHASING AND CONSTRUCTION. SUBMIT
SAMPLES FOR OWNER APPROVAL. APPROVED ALTERNATES
ARE ACCEPTABLE.
EQUAL TO TARKETT VCT II, COLOR BY OWNER FROM MANURFACTURER'S STANDARD COLORS
NOTE: PROVIDE 3" SOUND BATT IN BATHROOM AND
MECHANICAL ROOM WALLS.
FLOORING - (OFFICES, BREAK ROOM, BATHROOMS, HALLWAY, ETC) VINYL COMPOSITION TILE
room finish notes:
1. all floor finishes shall be in compiance w/ fbc accessibility chapter 3. exposed / polished concrete shall have slip-resistant finishes in compliance w/ fbc accessibility and the concrete polishing council. all flooring shall meet or exceed the floor dynamic coefficient of friction (dcof) as per accessibility codes for non-slip / slip resistant standards.
2. all gyp bd shall be 5/8" min. thickness. all exposed gyp bd shall be painted. moisture resistant gyp bd shall be "proroc" by certaineed or approved equal. FOR ALL MOISTURE RESISTANT CEILINGS, provide 2 x blocking @ 12" oc e.W.
3. INTERIOR WALLS AND CEILINGS IN THE RESTROOMS SHALL BE PAINTED AS FOLLOWS SHALL BE PAINTED WITH EPOXY PAINT AND PRIMER.
INSTALL PER THE MANUFACTURER'S REQUIREMENTS AND RECOMMENDATIONS.
4. CHANGES IN LEVEL: ALL FLOOR CHANGES IN LEVEL SHALL MEET FBC 2020 ACCESSIBILITY CODE. VERTICAL CHANGES IN LEVEL BETWEEN 1/4" HIGH MAX ARE PERMITTED TO BE VERTICAL . CHANGES IN LEVEL BETWEEN 1/4" HIGH AND 1/2" HIGH MAX SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2 CHANGES IN LEVEL GREATER THAN 1/2" HIGH SHALL BE RAMPED AND SHALL COMPLY W/ SECTIONS 405 & 406.
DESCRIPTIONCODE
WINDOW SCHEDULE
3'-4" W X 4'-8" H SINGLE HUNG
NOTE: THE BASIS OF DESIGN FOR THE WINDOWS SHALL BE
ALUMINUM FIXED "KAWNEER" SERIES 8400TL- FRAME COLOR
WHITE AS SELECTED BY OWNER FROM MANUFACTURER'S
STANDARD COLORS. APPROVED EQUALS ARE ACCEPTED IF
APPROVED BY OWNER.
W1
A PEMB METAL WALL PANELS - LIGHT GREY COLOR
DOOR & WINDOW NOTES:
1. REFER TO STRUCTURAL NOTES FOR WIND
PRESSURES - COMPONENTS AND CLADDING NOTES
2. PROVIDE DOOR AND WINDOW SUBMITTALS FOR
OWNER APPROVAL.
3. ALL EXTERIOR HARDWARE TO BE STAINLESS STEEL,
COMMERCIAL GRADE HARDWARE
4. ALL HARDWARE TO BE COMMERCIAL GRADE 1.
5. ALL EXTERIOR COMPONENTS SHALL BE A COMPLETE
WEATHER TIGHT ASSEMBLY AND SHALL BE INSTALLED
PER THE MANUFACTURER'S REQUIREMENTS AND
RECOMMENDATIONS.
6. COORDINATE DOOR KEYING WITH OWNER.
7. ALL DOOR THRESHOLDS SHALL BE ADA COMPLIANT
NOTE: THE BASIS OF DESIGN FOR THE OVERHEAD DOORS
SHALL BE ROLLING STEEL DOOR MODEL 610 AS
MANUFACTURED BY "OVERHEAD DOOR COMPANY",
STANDARD GALVANIZED STEEL CURTAIN , WHITE,
INSULATED, ELECTRIC OPERATION WITH CYLINDER LOCKS.
FRAME TO BE COLOR WHITE AS SELECTED BY OWNER FROM
MANUFACTURER'S STANDARD COLORS. APPROVED EQUALS
ARE ACCEPTABLE IF APPROVED BY OWNER .
D
H
HH
H H
H H H H H
H
H
D
D
D
D
L
L
A PEMB METAL WALL PANELS - LIGHT GREY COLOR
METAL ROOF FASCIA BY PEMB, WHITED (BEHIND GUTTER)
GUTTER, DOWNSPOUT - WHITE, & CONC. SPLASHBLOCKG
PROVIDE OWNER WITH A DEDUCT ALTERNATE
TO DELETE THE WALL INSULATION IN THE
BRACE TO STRUCTURE ABOVE AS REQUIRED
EQUIPMENT STORAGE AREA ONLY - ONLY THE THREE
EXTERIOR WALLS - NOT THE 2 HR WALL SEPARATION
C H
IT
EC
TU
ja r c h@ m sn
.c o m
R
US
S E
LL
J O H N S O N
A
R C H
IT
E C T
P L
A - 103 e a g le s p r in g s g o lf c o u r s e m a in t e n a n c e b u il d in g w a lt o n c o u n t y f lo r id a
GUTTER, DOWNSPOUT, & CONC. SPLASHBLOCKG
G
GUTTER, DOWNSPOUT, & CONC. SPLASHBLOCKG
G
GUTTER, DOWNSPOUT, & CONC. SPLASHBLOCKG
G
GUTTER, DOWNSPOUT, & CONC. SPLASHBLOCKG
G
GUTTER, DOWNSPOUT, & CONC. SPLASHBLOCKG
G
GUTTER, DOWNSPOUT, & CONC. SPLASHBLOCKG
elevations
SCALE: 3/16" = 1'-0"
rear elevation left side elevation
INSULATION SYSTEM
1. INSULATION SYSTEM SHALL BE "SIMPLE SAVER SYSTEM" double layer
W/ OSHA COMPLIANT FALL PROTECTION OR APPROVED EQUAL.
2. INSULATION SHALL BE IN COMPLIANCE W/ FBC 2023 ENERGY CODE
FOR METAL BUILDING, CLIMATE ZONE 2, ALL OTHER CATEGORY.
3. PROVIDE ROOF AND WALL INSULATION PER TABLE C402.1.3 FOR THE
STORAGE PORTION OF THE FACILITY.
4. PROVIDE A DEDUCTIVE ALTERNATE FOR DELETING THE WALL INSULATION
IN THE EXTERIOR WALLS OF THE STORAGE PORTION OF THE FACILITY.
Q Q
3.75
1.63
H H
H H
H H H
HH
HH
H
L
L
A PEMB METAL WALL PANELS - LIGHT GREY COLOR
GUTTER WHITEG
METAL ROOF FASCIA BY PEMB, WHITED (BEHIND GUTTER)
GUTTER WHITEG
METAL ROOF FASCIA BY PEMB, WHITED (BEHIND GUTTER)
METAL ROOF FASCIA BY PEMB, WHITE D
METAL ROOF FASCIA BY PEMB, WHITE D
METAL ROOF FASCIA BY PEMB, WHITE D
GUTTER, DOWNSPOUT, & CONC. SPLASHBLOCKGGUTTER, DOWNSPOUT, & CONC. SPLASHBLOCKG
LEGEND
PEMB METAL WALL PANELS - LIGHT GREY COLOR
STEEL PEMB FRAME
METAL ROOF PANELS
ROOF FASCIA BY PEMB, WHITE
PEMB Z-GIRTS
IN COMPLIANCE W/ FBC ENERGY CODE -
GUTTER, DOWNSPOUT, & CONC. SPLASHBLOCK
WINDOW OR DOOR - WHITE TRIM
CEILING - 5/8" TYPE X PAINTED GYP BD, COORDINATE W/ OWNER
CONCRETE FOUNDATION - REFER TO STRUCTURAL
3-5/8" METAL STUDS (6" @ PLUMBING WALLS IF REQUIRED)
CONCRETE FLOOR SLAB - REFER TO STRUCTURAL, PROVIDE VAPOR BARRIER
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
@ 16" OC W/ 5/8" TYPE X PAINTED GYP BD
SHOP DRAWINGS FROM THE METAL STUD MANUFACTURER
METAL STUD GAUGE, BRACING, ETC SHALL BE PER SIGNED AND SEALED
8 FT H METAL PANELS BY PEMB IN STORAGE AREA
2 HOUR WALL ASSEMBLY
R
WALL INSULATION W/ VAPOR RETARDER -
PROVIDE 3.5" BATT INSULATION ALL INTERIOR WALLS THAT ABUTT THE
MAIN STORAGE AREA AND ALL MECHANICAL AND BATHROOMS.
ON 6" 18 GA CEILING JOISTS @ 16" OC.
IN COMPLIANCE W/ FBC ENERGY CODE -
ROOF INSULATION W/ VAPOR RETARDER -
PROVIDE 2 HOUR WALL ASSEMBLY WHERE INDICATED ON PLAN
PROVIDE UL APPROVED FIRE CAULKING SYSTEM MATCHING FIRE RATING
OF WALL @ STEEL BEAM PENETRATIONS
LOUVERS - COORDINATE W/ MECHANICAL DRAWINGS
TYPICAL ALL SPACES EXCEPT MAIN STORAGE AREA
PROVIDE UL APPROVED 2HR ASSEMBLY UL I 506 OR APPROVED EQUAL
(2) LAYERS 5/8" TYPE ULIX GYP BD, LOOSELY LAID ON TOP OF MIN 6" D
STEEL JOISTS @16" OC AND (3) LAYERS TYPE ULIX GYP BD ATTACHED
TO THE BOTTOM OF THE STEEL CEILING JOISTS.
PROVIDE OWNER WITH A DEDUCT ALTERNATE
TO DELETE THE WALL INSULATION IN THE
BRACE TO STRUCTURE ABOVE AS REQUIRED
C H
IT
EC
TU
ja r c h@ m sn
.c o m
R
US
S E
LL
J O H N S
C H
IT
E C T
P L
A - 104
BUILDING SECTION
NTS
e a g le s p r in g s g o lf c o u r s e m a in t e n a n c e b u il d in g w a lt o n c o u n t y f lo r id a
B C
E
K
N
I
3.75
A
E
E
F
G
D
H
J
B
M
J
F
B
M
J
F
C
1.63 top of pemb frame top of pemb frame top of pemb frame top of pemb frame
16'-0"
B
EE
F
G
G
I
I
L
FXD.FXD.
REFRIGERATOR
9'- 6" (FIELD ADJUST)
SCALE: NTS
BREAK ROOM CABINET ELEVATIONS
4" TOE KICK -
MATCH WALL BASE
COORDINATE SIZE
W/ OWNER'S SELECTION
(1) ADJUSTABLE SHELF
PER CABINET
2' -1
NO SHELF
THIS CABINET
TOP OF
COUNTER
NOTE:
1. COORDINATE CABINET DESIGN WITH OWNER - SUBMIT
SHOP DRAWINGS FOR OWNER APPROVALS PRIOR
TO PURCHASE / CONSTRUCTION OF CABINETS.
2. CABINETS TO BE PLASTIC LAMINATE OVER 3/4" PLYWOOD.
3. HARDWARE TO BE STAINLESS STEEL, COMMERCIAL GRADE
SINK
UL 419 2 HR
P
Q Q
R
L
MW
ICE
MAKER
DEMISING WALL - U419 or approved equal
1. 3 5/8 " METAL STUDS - @ 16" OC - gauge and blocking per manufacturer's requirements - 25 ga min.
2. (2) layers of 5/8 " sheetrock firecode core panels EACH SIDE OF WALL - provide r19 insulation.
3. provide ul approved fire rated assembly at all voids & penetrations
APPLIANCE SCHEDULE:
COORDINATE W/ OWNER FOR FINAL SELECTIONS.
APPROVED EQUALS ARE ACCEPTABLE
GE 27.8 cu ft FRENCH DOOR REFRIGERATOR w/ Ice Maker S
S
T
U
Stainless Steel
GE Profile 2.2 cu. ft. Countertop Sensor MICROWAVE OVEN T
Model # PES7227SLSS
EDGESTAR IB250SS 15" wide 20 lb Built-In ICE MAKER U
Model # IB250SS
SHELF FOR
MICROWAVE
Model #PFE28KYNFS
Stainless Steel
Stainless Steel refer to floor plan
1/ 2" align w/ pemb frame mech rm metal siding detail per manufacturer's standard details metal siding detail per manufacturer's standard details
O
L
J JJ
BUILDING SECTION 1
a104
LEGEND
PEMB METAL WALL PANELS - LIGHT GREY COLOR
STEEL PEMB FRAME
METAL ROOF PANELS
ROOF FASCIA BY PEMB, WHITE
PEMB Z-GIRTS
IN COMPLIANCE W/ FBC ENERGY CODE -
GUTTER, DOWNSPOUT, & CONC. SPLASHBLOCK
WINDOW OR DOOR - WHITE TRIM
CEILING - 5/8" TYPE X PAINTED GYP BD, COORDINATE W/ OWNER
CONCRETE FOUNDATION - REFER TO STRUCTURAL
3-5/8" METAL STUDS (6" @ PLUMBING WALLS IF REQUIRED)
CONCRETE FLOOR SLAB - REFER TO STRUCTURAL, PROVIDE VAPOR BARRIER
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
@ 16" OC W/ 5/8" TYPE X PAINTED GYP BD
SHOP DRAWINGS FROM THE METAL STUD MANUFACTURER
METAL STUD GAUGE, BRACING, ETC SHALL BE PER SIGNED AND SEALED
8 FT H METAL PANELS BY PEMB IN STORAGE AREA
2 HOUR WALL ASSEMBLY
R
WALL INSULATION W/ VAPOR RETARDER -
PROVIDE 3.5" BATT INSULATION ALL INTERIOR WALLS THAT ABUTT THE
MAIN STORAGE AREA AND ALL MECHANICAL AND BATHROOMS.
ON 6" 18 GA CEILING JOISTS @ 16" OC.
IN COMPLIANCE W/ FBC ENERGY CODE -
ROOF INSULATION W/ VAPOR RETARDER -
PROVIDE 2 HOUR WALL ASSEMBLY WHERE INDICATED ON PLAN
PROVIDE UL APPROVED FIRE CAULKING SYSTEM MATCHING FIRE RATING
OF WALL @ STEEL BEAM PENETRATIONS
LOUVERS - COORDINATE W/ MECHANICAL DRAWINGS
TYPICAL ALL SPACES EXCEPT MAIN STORAGE AREA
PROVIDE UL APPROVED 2HR ASSEMBLY UL I 506 OR APPROVED EQUAL
(2) LAYERS 5/8" TYPE ULIX GYP BD, LOOSELY LAID ON TOP OF MIN 6" D
STEEL JOISTS @16" OC AND (3) LAYERS TYPE ULIX GYP BD ATTACHED
TO THE BOTTOM OF THE STEEL CEILING JOISTS.
PROVIDE OWNER WITH A DEDUCT ALTERNATE
TO DELETE THE WALL INSULATION IN THE
BRACE TO STRUCTURE ABOVE AS REQUIRED
B A
C
BATHROOM - MOUNTING HEIGHTS
E
D
TOILET ACCESSORIES
A TOILET TISSUE DISPENSER
B ADA SHWR GRAB BARS
C ADA MIRROR
D SOAP DISPENSER
E PAPER TOWEL DISPENSER & WASTE RECEPTACLE
F 36" ADA GRAB BAR
G 42" ADA GRAB BAR
H 18" VERTICAL ADA GRAB BAR
I ADA LAVATORY
J ADA WC
FG
H
I
JJ
F
NOTES:
1. COORDINATE TOILET ACCESSORIES WITH OWNER.
SUBMIT FULL SHOP DRAWINGS / CUT SHEETS FOR
OWNER APPROVAL DURING BIDDING.
2. COORDINATE MOUNTING HEIGHTS OF
ACCESSORIES WITH MANUFACTURER'S DATA FOR
ADA COMPLIANCE.
1'-0"
3'-6"
3'-4"
8" 2' -1
1'-
1/ 2"
3'-0"
2' -1
MEN
WOMEN
7'-6"
D1
D4
D4
D5
D6
D6 restroom restroom bathroom bathroom 2'-6"
5' -9
/2
3' -9
/4
/4
7' -6
/8
7/
36 X 36
ADA SHWR
36 X 36
ADA SHWR
A D
A D
F mechanical
2'-4 3/4" 7'-9"
D3
D8D8
A R
C H
IT
EC
TU
ja r c h@ m sn
.c o m
R
US
S E
LL
J O H N S
C H
IT
E C T
P L
A - 105 e a g le s p r in g s g o lf c o u r s e m a in t e n a n c e b u il d in g w a lt o n c o u n t y f lo r id a
BATHROOM ACCESSORY PRODUCT SELECTION SCHEDULE
NOTE: Specified products listed are for design intent/quality control, approved equals are accepted as approved by owner. Submit complete shop drawings and specs for owner review and approval.
COAT HOOK Bobrick B-6707 satin finished stainless steel finished single utility/coat hook.
Mirror - Bobrick B-292 1830 seried welded satin stainless steel finish framed mirror with 5" shelf, 18" x 30".
PTC; Bobrick B-262 classic series satin stainless steel finished surface mounted paper towel cabinet for folded paper.
SDISP, Bobrick B-2111 classic series surface mounted soap dispensers with satin stainless steel finish.
TPH; Bobrick B-6867 classic series surface mounted satin stainless steel finish two roll toilet paper holder.
ADA COMPLIANT LAV ( exposed piping shall be insulated per ada requirements)
ADA COMPLIANT WATER CLOSET -
ADA COMPLIANT WALL MOUNTED URINAL - kohler Steward Hybrid K-5244-ET-0 or owner approved equal
GB; Bobrick B-6806.99 series peened satin stainless steel finished grab bars for accessible toilet size 42" L side wall, 36" L back wall
Bobrick B 2260 satin stainless steel floor standing waste receptacle
K COAT HOOK, S.S.
TYPICAL
A
A
A
B
B
L ADA FOLDING SEAT
L
L
C
C
C
(3 LOCATIONS)
D
D
D
E
E
E
F
F
G
G
H
H
H
I
I
J
J
K
K
K
ENLARGED RESTROOM FLOOR PLAN
11'-3"
COORDINATE WALL THICKNES
W/ PLUMBING DRAWINGS (MIN. 6")
SD-1
CONTROL
VALVE
BY MECH
CONTROL
WALL
WATER
SUPPLY
CURTAIN
ROD
GB
ACCESSIBLE SHOWER - TRANSFER TYPE SHOWER WITH SEAT
7" 9"
4"
2"
GB
1'-6"
1'-
GB
SIDE BACK PLAN
2' -1
3'-0"
SIDE
FSB
1'-
3'-0"
3' -0
1'-0"
SHOWER
ACCESS
CLEARANCE
FSB
2' -1
1'-
3'-0"
3' -1
" 6
1. 36" X 36" CLEAR ACCESSIBLE TRANSFER TYPE SHOWER. DIMENSIONS ARE ABSOLUTE CLEAR INSIDE INCLUDING FINISHES.
2. PROVIDE HAND HELD SHOWER WITH SLIDE BAR, ADJUSTABLE MECHANISE AND BE OPERABLE WITH ONE HAND WITHOUT TIGHT GRASPING OR
TWISTING OF THE WRIST. MAX. 5 LB FORCE TO OPERATE.
3. GB BLKG TO BE DESIGNED FOR 250 LB LAT. AND DEAD LOADS.
4. HAND HELD SHOWER MUST HAVE A NON-POSITIVE SHUT OFF AND A HOSE THAT IS 59" LONG MIN.
3' -6
1'-5"
3/8" = 1'-0"
6" WALL
6" WALL
K
E
D
C
A
3'-2"
3' -2
3' -2 aa a a
3 3 3 3
3 3 3 3
2 2
2 2 2 2
2 2
1 1 a = 8.00 ft
MINIMUM LAP SPLICE LENGTH (IN.) - 3000 PSI CONCRETE
No. 3
6-in CMU WALL
8-in CMU WALL
12-in CMU WALL
No. 4 No. 5 No. 6 No. 7
39 81
DETAILING
21 23 29 37 50
RECOMMENED END HOOKS ANCHORAGE LENGTH (IN.) - 3000 PSI CONCRETE
No. 3
A or G
No. 4 No. 5 No. 6 No. 7 No. 8
6 8 10 12 14 16
D 2.25 3.00 3.75 4.50 5.25 6.00
MINIMUM LAP SPLICE LENGTH (IN.) - 1500 PSI NORMAL WEIGHT CMU
No. 8
1. GENERAL NOTES:
1.1. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH PROJECT SPECIFICATIONS
AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS. CONSULT
THESE DRAWINGS FOR OPENINGS, DEPRESSIONS, EQUIPMENT WEIGHTS AND LOCATIONS,
EMBEDDED ITEMS AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS.
1.2. DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. ANY DISCREPANCIES SHALL
BE BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD BEFORE PROCEEDING WITH
THE AFFECTED PART OF THE WORK.
1.3. NO STRUCTURAL MEMBER OR COMPONENT SHALL BE CUT, NOTCHED, OR OTHERWISE
ALTERED UNLESS APPROVED IN WRITING BY THE ENGINEER OF RECORD. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR ANY AND ALL COSTS INCURRED BY THE ENGINEER OF RECORD
FOR REVIEW OF ANY SUCH DEVIATIONS.
1.4. DO NOT SCALE DRAWINGS.
1.5. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS
COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES
AND SEQUENCE TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING
ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY
BRACING, AND TIEDOWNS.
1.6. DETAILS LABELED "TYPICAL DETAILS" ON THE DRAWINGS SHALL APPLY TO ALL SITUATIONS
OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY
DETAILED. THE APPLICABILITY OF THE DETAIL TO ITS LOCATION ON THE DRAWINGS CAN BE
DETERMINED BY THE TITLE OF DETAIL. SUCH DETAILS SHALL APPLY WHETHER OR NOT THEY
ARE REFERENCED AT EACH LOCATION. QUESTIONS REGARDING APPLICABILITY OF TYPICAL
DETAILS SHALL BE DETERMINED BY THE ENGINEER OF RECORD.
1.7. THE GENERAL CONTRACTOR SHALL COMPARE THE ARCHITECTURAL, MECHANICAL,
ELECTRICAL, PLUMBING, CIVIL AND STRUCTURAL DRAWINGS AND REPORT ANY
DISCREPANCIES BETWEEN EACH SET OF DRAWINGS AND WITHIN EACH SET OF DRAWINGS TO
THE ARCHITECT AND ENGINEER OF RECORD PRIOR TO THE FABRICATION AND INSTALLATION
OF ANY STRUCTURAL MEMBERS.
1.8. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED
STRUCTURE, AND DO NOT INDICATE THE METHOD OR MEANS OF CONSTRUCTION. THE
CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY
RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, PROCEDURES, TECHNIQUES,
SEQUENCE AND SAFETY. THE ENGINEER DOES NOT HAVE CONTROL OR CHARGE OF, AND
SHALL NOT BE RESPONSIBLE FOR, CONSTRUCTION MEANS, METHODS, TECHNIQUES,
SEQUENCES, OR PROCEDURES, FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION
WITH THE WORK, FOR THE ACTS OR OMISSION OF THE CONTRACTOR, SUBCONTRACTOR OR
ANY OTHER PERSONS PERFORMING ANY OF THE WORK, OR FOR THE FAILURE OF ANY OF
THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
1.9. THE REVIEW OF SUBMITTALS AND/OR SHOP DRAWINGS BY THE STRUCTURAL ENGINEER DOES
NOT RELIEVE THE CONTRACTOR OF THE SOLE RESPONSIBILITY TO REVIEW AND CHECK SHOP
DRAWINGS PRIOR TO SUBMITTAL TO THE STRUCTURAL ENGINEER. THE CONTRACTOR
REMAINS SOLELY RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE
PREPARATION OF SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, AND
DIMENSIONS SPECIFIED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR ALSO SHALL BE
RESPONSIBLE FOR MEANS, METHOD, TECHNIQUES, SEQUENCES, AND PROCEDURES OF
CONSTRUCTION.
1.10. PERIODIC SITE OBSERVATION BY FIELD REPRESENTATIVES OF ATLAS ENGINEERING AND
CONSULTING, LLC IS SOLELY FOR THE PURPOSE OF DETERMINING IF THE WORK OF THE
CONTRACTOR IS PROCEEDING IN GENERAL ACCORDANCE WITH THE STRUCTURAL CONTRACT
DOCUMENTS. THIS LIMITED SITE OBSERVATION SHALL NOT BE CONSTRUED AS EXHAUSTIVE
OR CONTINUOUS TO CHECK THE QUALITY OR QUANTITY OF THE WORK.
1.11. ALL STRUCTURES REQUIRE PERIODIC MAINTENANCE TO EXCEED LIFE SPAN AND TO ENSURE
STRUCTURAL INTEGRITY FROM EXPOSURE TO THE ENVIRONMENT. A PLANNED PROGRAM OF
MAINTENANCE SHALL BE ESTABLISHED BY THE OWNER. THIS PROGRAM SHALL INCLUDE
ITEMS SUCH AS, BUT NOT LIMITED TO, PAINTING OF STRUCTURAL STEEL, PROTECTIVE
COATINGS FOR CONCRETE, SEALANTS, CAULKED JOINTS, EXPANSION JOINTS, CONTROL
JOINTS, SPALLS AND CRACKS IN CONCRETE, AND PRESSURE WASHING OF EXPOSED
STRUCTURAL ELEMENTS EXPOSED TO SALT ENVIRONMENT OR OTHER HARSH CHEMICALS.
1.12. STRUCTURAL ENGINEER OF RECORD IS NOT RESPONSIBLE FOR THE DESIGN OF STEEL STAIRS, HANDRAILS, CURTAIN WALL/WINDOW WALL SYSTEMS, COLD-FORMED STEEL FRAMING, OR
OTHER SYSTEMS NOT SHOWN IN THE STRUCTURAL DOCUMENTS. SUCH SYSTEMS SHALL BE
DESIGNED, FURNISHED, AND INSTALLED AS REQUIRED BY OTHER PORTIONS OF THE
CONTRACT DOCUMENTS.
1.13. ALL CONSTRUCTION SHALL CONFORM TO THE FLORIDA BUILDING CODE 7TH EDITION (2020).
REFERENCE TO OTHER CODES OR STANDARD SPECIFICATIONS REFER TO THE LATEST EDITION
OF SUCH CODES OR SPECIFICATIONS, UNLESS STATED OTHERWISE.
1.14. NO PROVISIONS HAVE BEEN MADE FOR VERTICAL OR HORIZONTAL EXPANSION EXCEPT AS
SHOWN ON CONTRACT DOCUMENTS.
1.15. FINISH FLOOR ELEVATION (FIRST FLOOR) OF 0"-0" IS USED AS A REFERENCE ELEVATION. SEE
CIVIL DRAWINGS FOR ACTUAL ELEVATION.
1.16. THE USE OF REPRODUCTIONS OF THESE CONTRACT DOCUMENTS AND USE OF CAD FILES BY
ANY CONTRACTOR, SUBCONTRACTOR, ERECTOR, FABRICATOR OR MATERIAL SUPPLIER IN LIEU
OF PREPARATION OF SHOP DRAWINGS IS PROHIBITED UNLESS PRIOR WRITTEN APPROVAL IS
OBTAINED FROM ENGINEER OF RECORD.
1.17. IN THE EVENT THAT THE STRUCTURAL CONTRACTS DRAWINGS AND SPECIFICATIONS
CONFLICT ON INFORMATION, THE STRUCTURAL CONTRACT DRAWINGS SHALL SUPERSEDE
THE SPECIFICATIONS.
2. CODE DESIGN:
2.1. STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE 2020 FLORIDA BUILDING CODE.
2.2. GRAVITY LOADS
2.2.1. UNIFORM FLOOR LIVE LOADS (REDUCED AS ALLOWED BY THE BUILDING CODE):
ATTICS W/O STORAGE 10 PSF
ATTICS W/ STORAGE 20 PSF
SLEEPING AREAS 30 PSF
ROOMS (OTHER THAN SLEEPING) 40 PSF
BALCONIES 40 PSF
GARAGES 40 PSF
STAIRS 40 PSF
2.2.2. UNIFORM ROOF LIVE LOADS (REDUCED AS ALLOWED BY THE BUILDING CODE):
ROOF 20PSF
PONDING AND DRIFT EFFECTS HAVE BEEN INCLUDED IN DESIGN.
2.3. WIND LOADS (ASCE 7-16):
BASIC WIND SPEED = 134 MPH (INTERPOLATED VALUE)
STRUCTURAL RISK CATEGORY = II
WIND EXPOSURE CATEGORY = B
ENCLOSURE CLASSIFICATION = ENCLOSED
INTERNAL PRESSURE COEFFICIENT = 0.18 +/-
2.4. FLOOD DESIGN DATA:
FLOOD ZONE = X
BFE = N/A
PANEL NO = 12131C0260G
2.5. ROOF RAIN LOAD DESIGN DATA:
RAIN LOAD = 5 PSF
RAIN INTENSITY (i) = 4.5 IN/HR
3. FOUNDATIONS:
3.1. THE FOUNDATIONS ARE DESIGNED FOR AN ANTICIPATED ALLOWABLE SOIL BEARING
PRESSURE OF 2,000 PSF ON COMPACTED FILL IF GEOTECHNICAL INVESTIGATION HAS NOT
BEEN CONDUCTED.
3.2. REGARDLESS OF WHETHER OR NOT A GEOTECHNICAL INVESTIGATION IS PERFORMED, NO
WARRANTIES, EXPRESSED OR IMPLIED, ARE MADE BY ATLAS ENGINEERING AND CONSULTING,
LLC FOR THE PERFORMANCE OF THE FOUNDATION.
3.3. AT A MINIMUM, SITE PREPARATION WORK SHALL INCLUDE:
3.3.1. STRIPPING AND GRUBBING OF THE BUILDING FOOTPRINT PLUS A MARGIN OF 5 FEET
AROUND THE BUILDING, REMOVING ALL ORGANIC MATERIALS.
3.3.2. PROOF ROLLING THE BUILDING SITE TO LOCATE ANY UNFORESEEN SOFT AREAS. ANY
SOFT AREAS SHALL BE\ EXCAVATED AND REPLACED WITH CLEAN FILL. A DENSITY OF AT
LEAST 95% FOR A DEPTH OF 2 FEET IS REQUIRED UNDER THE BUILDING FOOTPRINT.
3.3.3. ALL FILL SHALL BE CLEAN SAND AND FREE OF ORGANIC MATERIALS. COMPACT FILL IN 12
INCH (UNCOMPACTED THICKNESS) LIFTS TO A MINIMUM OF 95% OF THE MODIFIED
PROCTOR MAXIMUM DRY DENSITY VALUE.
3.3.4. EXCAVATIONS FOR FOUNDATIONS SHALL BE COMPACTED TO 95% FOR A DEPTH OF AT
LEAST 2 FEET BELOW THE BOTTOM OF THE FOUNDATION.
3.3.5. DEWATERING MAY BE REQUIRED TO ACHIEVE THE REQUIRED COMPACTION VALUES, AND
IF USED, SHOULD DRAW DOWN THE WATER LEVEL TO AT LEAST 2 FEET BELOW THE
BOTTOM OF THE EXCAVATION.
3.4. SLABS ON GRADE SHALL BE PLACED OVER A 15 MIL, CLASS "B" VAPOR RETARDER. VAPOR
RETARDER SHALL BE LAPPED A MINIMUM OF 6", OR AS RECOMMENDED BY THE
MANUFACTURER (WHICHEVER IS GREATER) AND TAPED AT ALL JOINTS. ALL PUNCTURES IN
THE VAPOR RETARDER SHALL BE REPAIRED PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
ALL PENETRATIONS THROUGH THE VAPOR RETARDER (COLUMNS, PLUMBING, CONDUITS, ETC)
SHALL BE SEALED PER MANUFACTURER'S WRITTEN INSTRUCTIONS. VAPOR RETARDER SHALL
BE CONTINUOUS UNDER WALL FOUNDATIONS OR SEALED TO EXTERIOR WALLS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
4. CONCRETE:
4.1. CONCRETE SHALL BE PLACED AND CURED ACCORDING TO ACI STANDARDS AND
SPECIFICATIONS.
4.2. UNLESS NOTED OTHERWISE, ALL CONCRETE SHALL BE NORMAL WEIGHT AND HAVE THE
FOLLOWING MINIMUM 28 DAY COMPRESSIVE STRENGTHS:
4.2.1. FOUNDATIONS & SLAB-ON-GRADE 3,000 PSI
4.2.2. STRUCTURAL SLABS 4,000 PSI
4.2.3. CIP BEAMS, COLUMNS & WALLS 4,000 PSI
4.2.4. EXTERIOR RETAINING WALLS 4,000 PSI
4.3. SUBMIT PROPOSED MIX DESIGN WITH RECENT FIELD CYLINDER OR LAB TESTS FOR REVIEW
PRIOR TO USE. MIX SHALL BE UNIQUELY IDENTIFIED BY MIX NUMBER OR OTHER POSITIVE
IDENTIFICATION. MIX SHALL MEET THE REQUIREMENTS OF ASTM C33 FOR COARSE
AGGREGATE.
4.4. CONCRETE SHALL COMPLY WITH THE REQUIREMENTS OF ASTM STANDARD C94 FOR
MEASURING, MIXING, TRANSPORTING, ETC. CONCRETE TICKETS SHALL BE TIME STAMPED
WHEN CONCRETE IS BATCHED.
4.5. THE MAXIMUM TIME ALLOWED FROM THE TIME THE MIXING WATER IS ADDED UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED ONE AND ONE HALF (1-1/2) HOURS. IF
FOR ANY REASON THERE IS A LONGER DELAY THAN THAT STATED ABOVE, THE CONCRETE
SHALL BE DISCARDED. IT SHALL BE THE RESPONSIBILITY OF THE TESTING LAB TO NOTIFY THE
OWNER'S REPRESENTATIVE AND THE CONTRACTOR OF ANY NONCOMPLIANCE WITH THE
ABOVE.
4.6. CALCIUM CHLORIDES SHALL NOT BE UTILIZED; OTHER ADMIXTURES MAY BE USED ONLY WITH
THE APPROVAL OF THE ENGINEER.
4.7. CONCRETE MIX DESIGNS SHALL INCLUDE A WRITTEN DESCRIPTION INDICATING WHERE EACH
PARTICULAR MIX IS TO BE PLACED WITHIN THE STRUCTURE.
4.8. CONDUITS, PIPES AND SLEEVES SHALL BE PLACED AND SPACED IN ACCORDANCE WITH ACI 318, 20.6.
4.9. CONCRETE DESIGN MIX SUBMITTALS SHALL INCLUDE TESTED, STATISTICAL BACK-UP DATA AS
PER 26.4.4 OF ACI 318.
4.10. CONCRETE SLABS ON GRADE SHALL BE REINFORCED WITH 6x6 W1.4xW1.4 STEEL MESH OR
SYNTHETIC FIBERS AT A MINIMUM RATE OF 3.0 LBS/CY, OR AS RECOMMENDED BY THE FIBER
MANUFACTURER FOR CONTROL OF TEMPERATURE AND SHRINKAGE/CRACKING, WHICHEVER
IS GREATER. UNLESS NOTED OTHERWISE.
4.11. WHEN WATER-BASED ADHESIVE ARE BEING USED ON CONCRETE SURFACES, THE
CONTRACTOR SHALL VERIFY THAT THE WATER CONTENT OF THE CONCRETE IS WITHIN THE
ALLOWABLE RANGE BEFORE INSTALLATION.
4.12. CHAMFER OR ROUND ALL EXPOSED CORNERS A MINIMUM OF 3/4".
5. REINFORCING STEEL
5.1. SHALL BE ASTM A615 GRADE 60 DEFORMED BARS, FREE FROM OIL, SCALE AND RUST AND
PLACED IN ACCORDANCE WITH THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF
ACI STANDARDS AND SPECIFICATIONS.
5.2. REINFORCING STEEL SHALL HAVE THE FOLLOWING CONCRETE CLEAR COVER UNO (PER ACI
318-05 PAR.7.7.1)
5.2.1. CONCRETE CAST AGAINST EARTH: 3"
5.2.2. FORMED CONCRETE EXPOSED
TO EARTH OR WEATHER: 2" (#6 BARS & LARGER)
1-1/2" (#5 BARS & SMALLER)
5.2.3. CONCRETE NOT EXPOSED
TO EARTH OR WEATHER: 3/4" (SLABS)
1" (WALLS)
1-1/2" (STIRRUPS & TIES)
5.3. SECURE APPROVAL OF SHOP DRAWINGS PRIOR TO COMMENCING FABRICATION.
5.4. PROVIDE STANDARD HOOKS AT DISCONTINUOUS ENDS OF ALL TOP BARS.
5.5. WHERE REINFORCING IS SHOWN CONTINUOUS, SPLICE BOTTOM BARS OVER SUPPORTS AND
TOP BARS AT CENTER OF SPAN. ALL OTHER LAP SPLICES SHALL BE IN ACCORDANCE WITH
SPLICE TABLES AND DETAILS SHOWN ON DRAWINGS.
5.6. PROVIDE DOWELS INTO FOOTINGS, PILE CAPS, SUPPORT BEAMS, ETC. TO MATCH VERTICAL
BARS WITH CLASS B TENSION LAP SPLICES, U.N.O.
5.7. WHERE HOOKS ARE SHOWN ON THE PLANS OR DETAILS, HOOKS SHALL BE DETAILED TO
EXTEND DEEP ENOUGH INTO SUPPORTING STRUCTURE TO DEVELOP THE FULL STRENGTH OF
THE HOOKED BAR. PROVIDE ADDITIONAL TIES OR STIRRUPS IN SUPPORTING STRUCTURE AS
REQUIRED TO SATISFY ACI 318 HOOK DEVELOPMENT, CONFINEMENT, AND ANCHORAGE
CRITERIA.
5.8. ALL REINFORCEMENT SHALL BE BENT COLD, UNLESS OTHERWISE APPROVED BY THE
STRUCTURAL EOR.
5.9. SHOP DRAWINGS SHOWING ALL FABRICATION DIMENSIONS AND LOCATIONS FOR PLACING
REINFORCING STEEL IN MAT SLABS, CAST-IN-PLACE WALLS, AND STRUCTURAL SLABS SHALL
BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION.
5.10. ALL CONCRETE REINFORCEMENT SHALL BE DETAILED, FABRICATED, LABELED, SUPPORTED
AND SPACED IN FORMS AND SECURED IN PLACE IN ACCORDANCE WITH THE PROCEDURES
AND REQUIREMENTS FOR REINFORCED CONCRETE, "ACI 318" AND THE "MANUALS OF
STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES," ACI 315 (LATEST
EDITION).
5.11. ALL REINFORCING STEEL AND EMBEDMENTS SHALL BE SECURELY TIED AND SUFFICIENTLY
SUPPORTED TO MAINTAIN THE POSITION WITHIN SPECIFIED TOLERANCES DURING ALL
CONSTRUCTION ACTIVITIES. "WET STICKING” DOWELS INTO CONCRETE IS NOT PERMITTED.
5.12. CONTINUOUS REINFORCEMENT SHALL BE PROVIDED WHEREVER POSSIBLE. REINFORCEMENT
SHALL BE SPLICED ONLY AS SHOWN OR NOTED IN THE STRUCTURAL CONTRACT DOCUMENTS.
STAGGER SPLICES WHERE POSSIBLE; USE FULL TENSION SPLICE (CLASS "B") UNLESS NOTED
OTHERWISE. DOWELS SHALL MATCH THE SIZE AND SPACING OF THE SPECIFIED
REINFORCEMENT AND SHALL BE LAPPED WITH FULL TENSION SPLICES (CLASS "B") UNLESS
NOTED OTHERWISE. TERMINATE BARS WITH STANDARD HOOKS.
5.13. REINFORCING STEEL SHALL NOT BE WELDED OR TACK WELDED UNLESS APPROVED BY THE
STRUCTURAL EOR.
5.14. ALL STEEL REINFORCING USED IN SLAB-ON-GRADE CONSTRUCTION IS REQUIRED TO BE
SUPPORTED IN THE CENTER TO UPPER ONE THIRD OF THE SLAB.
6. WELDED WIRE FABRIC:
6.1. SHALL CONFORM TO ASTM A-185, FREE FROM OIL, SCALE AND RUST AND PLACED IN
ACCORDANCE WITH THE TYPICAL PLACING DETAILS OF ACI STANDARDS AND SPECIFICATIONS.
6.2. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES.
6.3. ALL WELD WIRE MESH USED IN SLAB-ON-GRADE CONSTRUCTION IS REQUIRED TO BE
SUPPORTED IN THE CENTER TO UPPER ONE THIRD OF THE SLAB.
7. WOOD:
7.1. STRUCTURAL GLUED LAMINATED TIMBER SHALL BE PRODUCED IN ACCORDANCE WITH THE
AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC). MINIMUM ALLOWABLE BENDING
STRESS SHALL BE 2,400 PSI (DRY CONDITIONS).
7.2. PROVIDE DRESSED SEASONED LUMBER, S4S, WITH A MAXIMUM MOISTURE CONTENT OF 19%
AT TIME OF DRESSING AS LISTED BELOW.
7.2.1. INTERIOR AND EXTERIOR LOAD-BEARING WALLS:
SOUTHERN PINE, NO. 2 GRADE.
7.2.2. LINTELS, FLOOR JOISTS AND BEAMS:
SOUTHERN PINE, NO. 2 GRADE.
7.2.3. WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE FOUNDATION GRADE
PRESSURE-TREATED. USE GALVANIZED NAILS IN PRESSURE-TREATED WOOD. THE
PROTECTIVE COATING ON LIGHT GAUGE STEEL CONNECTIONS IN CONTACT W/
PRESSURE-TREATED WOOD SHALL BE IN ACCORDANCE WITH THE CONNECTOR
MANUFACTURERS RECOMMENDATIONS.
7.3. ENGINEERED LUMBER PRODUCTS
7.3.1. PARALLEL STRAND LUMBER (PSL) SHALL HAVE THE FOLLOWING MINIMUM ALLOWABLE
STRESSES AND PROPERTIES:
ALLOWABLE BENDING STRESS F/B = 2900 PSI
COMPRESSION PERPENDICULAR TO GRAIN F/C┴ = 750 PSI
COMPRESSION PARALLEL TO GRAIN F/C││ = 2900 PSI
HORIZONTAL SHEAR F/V = 290 PSI
MODULUS OF ELASTICITY E = 2,000,000 PSI
7.3.2. LAMINATED VENEER LUMBER (LVL) SHALL HAVE THE FOLLOWING MINIMUM ALLOWABLE
STRESSES AND PROPERTIES:
ALLOWABLE BENDING STRESS F/B = 2600 PSI
COMPRESSION PERPENDICULAR TO GRAIN F/C┴ = 750 PSI
COMPRESSION PARALLEL TO GRAIN F/C││ = 2510 PSI
HORIZONTAL SHEAR F/V = 285 PSI
MODULUS OF ELASTICITY E = 2,000,000 PSI
7.3.3. LAMINATED STRAND LUMBER (LSL) SHALL HAVE THE FOLLOWING MINIMUM ALLOWABLE
STRESSES AND PROPERTIES:
ALLOWABLE BENDING STRESS F/B = 1700 PSI
COMPRESSION PERPENDICULAR TO GRAIN F/C┴ = 710 PSI
COMPRESSION PARALLEL TO GRAIN F/C││ = 1835 PSI
HORIZONTAL SHEAR F/V = 425 PSI
MODULUS OF ELASTICITY E = 1,300,000 PSI
7.3.4. GLULAM BEAMS SHALL HAVE THE FOLLOWING MINIMUM ALLOWABLE STRESSES AND
PROPERTIES:
ALLOWABLE BENDING STRESS F/B = 3000 PSI
COMPRESSION PERPENDICULAR TO GRAIN F/C┴ = 805 PSI
TENSION PARALLEL TO GRAIN F/T││ = 1350 PSI
HORIZONTAL SHEAR F/V = 300 PSI
MODULUS OF ELASTICITY E = 2,100,000 PSI
7.3.5. PRESERVED GLULAM BEAMS SHALL HAVE THE FOLLOWING MINIMUM ALLOWABLE
STRESSES AND PROPERTIES:
ALLOWABLE BENDING STRESS F/B = 2400 PSI
COMPRESSION PERPENDICULAR TO GRAIN F/C┴ = 740 PSI
HORIZONTAL SHEAR F/V = 300 PSI
MODULUS OF ELASTICITY E = 1,800,000 PS
7.4. STRUCTURAL PANELS
7.4.1. FLOOR PANELS SHALL BE CONSTRUCTED WITH TONGUE AND GROOVE APA RATED,
EXPOSURE 1, 23
32" PLYWOOD. FLOOR PANELS SHALL BE GLUED AND NAILED W/ 10d RING
SHANK NAILS @ 4" O/C AT PANEL EDGES AND AT 6" O/C IN THE FIELD.
7.4.2. WALL PANELS SHALL BE CONSTRUCTED WITH APA RATED, EXPOSURE 1, 15 32" SHEATHING, SHEATHING SHALL BE ATTACHED WITH 10d COMMON NAILS @ 3" O/C AT PANEL EDGES
AND 6" O/C IN THE FIELD. ALL PANEL EDGES SHALL BE BLOCKED.
7.4.3. ROOF PANELS SHALL BE CONSTRUCTED WITH APA RATED, EXPOSURE 1, 19 32" SHEATHING.
SHEATHING SHALL BE ATTACHED WITH 10d RING SHANK NAILS @ 4" O/C AT PANEL EDGES
AND AT 6" O/C IN THE FIELD. ALL PANEL EDGES SHALL BE BLOCKED OR ATTACHED WITH
SIMPSON PSCA PANEL SHEATHING CLIPS. NAIL HEADS SHALL NOT PENETRATE THE
OUTER SURFACE OF SHEATHING.
7.5. FABRICATED WOOD TRUSSES
7.5.1. DESIGN OF WOOD TRUSSES SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
SUBMIT SHOP DRAWINGS, DESIGN LOAD DATA, AND SUPPORT REACTIONS SEALED BY AN
ENGINEER LICENSED IN THE PROJECT STATE. REVIEW OF SHOP DRAWINGS SHALL BE FOR
CONFORMANCE WITH THE CONTRACT DOCUMENTS WITH REGARD TO TRUSS
CONFIGURATION, AND THE CONTRACTOR'S INTERPRETATION OF DESIGN LOADS AND
DETAILS. SUCH REVIEW SHALL NOT RELIEVE THE CONTRACTOR OF THE FULL
RESPONSIBILITY FOR THE DESIGN OF THE TRUSSES OR TRUSS CONNECTIONS NOT
SPECIFICALLY DETAILED IN THE CONTRACT DOCUMENTS.
7.5.2. ERECTION AND TEMPORARY BRACING OF PREFABRICATED WOOD TRUSSES SHALL BE IN
CONFORMANCE WITH THE RECOMMENDATIONS OF THE TRUSS MANUFACTURER AND
THE TRUSS PLATE INSTITUTE'S "BRACING WOOD TRUSSES: COMMENTARY AND
RECOMMENDATIONS".
7.5.3. SECURE EACH COMMON ROOF TRUSS/RAFTER TO TOP PLATE WITH SIMPSON H-10 OR H-7
HURRICANE CLIP AT ALL BEARING POINTS. USE SIMPSON H-7 AT GIRDER TRUSSES.
PROVIDE A MINIMUM OF TWO STUDS UNDER GIRDER TRUSS END BEARING.
7.5.4. TRUSSES ON SITE PRIOR TO INSTALLATION SHALL BE STORED IN A VERTICAL POSITION
WITH SUPPORT POINTS PROVIDED AT FINAL BEARING POINTS AND BRACED TO AVOID
TIPPING.
7.5.5. INSTALLATION OF ALL TRUSSES SHALL BE DONE USING A SPREADER BAR WITH A THREE
POINT VERTICAL PICK AND CARE IS TO BE USED IN LIFTING TO MINIMIZE HORIZONTAL
BENDING.
7.5.6. IMPROPER HANDLING OF THE TRUSSES AS NOTED ABOVE AND IN THE SPECIFICATIONS
SHALL MEAN REMOVAL OF THE TRUSSES FROM THE JOB SITE.
7.5.7. DOUBLE TRUSSES SHALL BE NAILED TOGETHER W/ 10d @12" O.C. EACH SIDE, TOP AND
BOTTOM CHORDS & WEBS.
7.5.8. TRUSS TO TRUSS CONNECTIONS SHALL BE VERIFIED BY THE TRUSS DESIGNER.
7.5.9. CONTRACTOR TO REFER TO "STANDARD FOR HURRICANE RESISTANT CONSTRUCTION
SSTD 10-99 FOR FRAMING REQUIREMENTS OF WOOD FRAMED WALL SYSTEMS.
7.5.10. FLOOR TRUSS LOADS:
FLOOR TRUSSES SHALL BE DESIGNED FOR THE FOLLOWING LOADS
UNLESS A SPECIAL LOADING PATTERN IS PROVIDED BY THE
STRUCTURAL ENGINEER OF RECORD.
TOP CHORD LIVE LOAD 40 PSF
TOP CHORD DEAD LOAD 20 PSF
BOTTOM CHORD DEAD LOAD 10 PSF
TOTAL 70 PSF
7.5.11. ROOF TRUSS LOADS:
ROOF TRUSSES SHALL BE DESIGNED FOR THE FOLLOWING LOADS
UNLESS A SPECIAL LOADING PATTERN IS PROVIDED BY THE
STRUCTURAL ENGINEER OF RECORD.
TOP CHORD LIVE LOAD 20 PSF
TOP CHORD DEAD LOAD 20 PSF
BOTTOM CHORD DEAD LOAD 10 PSF
TOTAL 40 PSF
7.6. CONNECTIONS
7.6.1. CONNECTIONS FOR STRUCTURAL TIMBER SHALL BE GALVANIZED STRONG TIE
CONNECTORS BY THE SIMPSON COMPANY OR APPROVED EQUAL. CONNECTORS SHALL
FOLLOW MANUF. CORROSION PROTECTION RECOMMENDATIONS.
7.6.2. THE NUMBER OF FASTENERS PER CONNECTION SHALL BE THE MAX. ALLOWED FOR THAT
PARTICULAR FASTENER.
8. TIE-DOWN NOTES:
8.1. ANCHOR TIE-DOWN RODS SHALL HAVE A MINIMUM SHAFT DIAMETER OF 1/2" (ONE HALF INCH) U.N.O.
8.2. TIE-DOWN RODS MAY BE CONNECTED DIRECTLY TO THE PLAN SPECIFIED 5/8" ANCHOR BOLTS
USING A SIMPSON CNW5/8"-1/2" TRANSITION COUPLER NUT ABOVE THE REQUIRED BP3-5/8"
AND 5/8" NUT ATOP THE SILL PLATE.
8.3. TIE-DOWN DIRECT CONNECTION MAY BE USED BY UTILIZING SIMPSON SET ANCHORAGE
ADHESIVE WITH MINIMUM ROD EMBEDMENT OF 6" WHEREVER CAST-IN-PLACE ANCHOR
BOLTS ARE SPECIFIED FOR COUPLED EXTENSION TO ABOVE.
8.4. ANY PLACE WHERE A TIE-DOWN LOCATION IS FILLED WITH STUDS; USE A SIMPSON LTTI31 OR
HDU5 HOLDOWN CONNECTED AT THE TOP AND BOTTOM OF A MINIMUM 2PLY STUD PACK TO
PRESERVE TENSION LOAD PATH TO FLOORS ABOVE AND/OR BELOW. RESUME INDICATED
TIE-DOWN ROD PATH AT ENDS OF STUD PACK IF POSSIBLE.
8.5. SIMPSON LTTI31 & HDU5 HOLDOWNS SHALL BE ANCHORED INTO GROUT FILLED CMU WALLS
OR PIERS WITH A SIMPSON SB5/8 OR SSTB ANCHOR BOLT WITH EMBEDMENT PER MFGR.
RECOMMENDATION.
8.6. RODS SHALL INSTALLED PLUMB. THE MAXIMUM ALLOWABLE ROD DRIFT FROM PLUMB
SHOULD NOT EXCEED 1.33 DEGREES OR MAXIMUM CENTERLINE OFFSET DISTANCE OF 1.75" PER
FLOOR.
8.7. TIE-DOWN RODS SHALL HAVE A SIMPSON BP-3 WITH NUT ATOP THE TERMINAL TOP PLATE.
RODS AT SLOPED OR RAKED PLATES SHALL REQUIRE HILLSIDE WASHERS BETWEEN BP-3 AND
NUT TO LEVEL.
8.8. ALL RODS ARE TO BE TIGHTENED AT EACH FLOOR AND THE TOP PLATE CONNECTION AFTER
ROOF IS FULLY LOADED, JUST PRIOR TO GYPSUM BOARD INSTALLATION. ALL RODS WITH BP
AND NUT CONNECTIONS TO THE BOTTOM SIDE OF THE FIRST FLOOR FRAMING SHALL BE
TIGHTENED AT THE END OF THE CONSTRUCTION PROCESS PRIOR TO C.O. OPTIONAL:
CONTRACTOR MAY INSTALL A SIMPSON BPRTUD AND RTUD TAKE-UP DEVICE AT THE
TERMINAL TOP PLATE CONNECTION TO REMOVED UNWANTED SYSTEM SLACK DUE TO
STRUCTURE SETTLING OR CREEP.
9. MASONRY WALLS:
9.1. ALL MASONRY CONSTRUCTION SHALL CONFORM TO ACI 530/ASCE 5/TMS 402 "BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES" AND ACI 530.1/ASCE 6/TMS 602 "SPECIFICATION
FOR MASONRY STRUCTURES", LATEST EDITION.
9.2. MASONRY UNITS SHALL MEET ASTM C-90 FOR HOLLOW LOAD BEARING TYPE MASONRY WITH UNIT STRENGTH OF 1900 PSI ON THE NET AREA (f'm = 1500 PSI). MORTAR SHALL BE TYPE "M" OR
"S" AND MEET ASTM C-270.
9.3. GROUT SHALL BE 3000 PSI MINIMUM COMPRESSIVE STRENGTH AND MEET ASTM C-476 AND HAVE A SLUMP BETWEEN 8" AND 11" WITH WATER CM RATIO OF 0.55 MAXIMUM AND WITH 3/8"
MAXIMUM AGGREGATE.
9.4. PROVIDE HOOKED DOWELS IN FOUNDATIONS FOR VERTICAL REINFORCING ABOVE. REFER TO
TABLE FOR SPLICE LENGTH.
9.5. BLOCK CELLS SHALL BE GROUT FILLED WITH VERTICAL REINFORCING BARS AT CORNERS, INTERSECTIONS, EACH SIDE OF OPENINGS AND AS SHOWN ON THE DRAWINGS.
9.6. DOWELS SHALL BE USED TO PROVIDE CONTINUITY INTO THE STRUCTURE ABOVE AND/OR
BELOW, UNLESS NOTED OTHERWISE.
9.7. USE METAL LATH, MORTAR OR SPECIAL UNITS TO CONFINE CONCRETE AND GROUT TO…
This is the start of the file's text. The full file is on GovTribe.