IME-35210-N4.pdf

PDF 5 MB Posted

Attached to
DRYDOCK REPAIRS FOR NOAA SHOP PISCES Federal contract opportunity
Solicitation number
EA-133M-16-RP-0112
Issued by
Department of Commerce National Oceanic and Atmospheric Administration

View the file

Other files for this federal contract opportunity

Other files attached to DRYDOCK REPAIRS FOR NOAA SHOP PISCES, newest first.
File Type Posted
Amendment_0002.pdf.pdf PDF
AMC-000-3C.pdf PDF
Amendment_0001.pdf PDF
(134)Knuckle_Boom_Crane.pdf PDF
(035)FoodServiceEquipment.pdf PDF
FV01-000-01_(HVAC_Loads) AS-BUILT_2006-09-14)ab.pdf PDF
dwg529-_FP01_Bilge_and_Ballast_System_Diagram_(2_sheets).pdf PDF
dwg524-_FP18_Scientific_SW_System_Diagram_(2_sheets).pdf PDF
dwg085-_FA01_Outboard_Profile.pdf PDF
(008)Bow_Thruster.pdf PDF
Consilium_SAL_T2_Spare_Parts_List_T2_Bottom_Part_Spares.pdf PDF
(085)fuel_oil_purifier.pdf PDF
IME-35190-P2.pdf PDF
AMC-300-1 _Overhaul_of_Electrical_Rotating_Machinery_(10_pages).pdf PDF
HB-631_FF04_Paint_Schedule.pdf PDF
FP07_Compressed_Air_System_Diagram.pdf PDF
AMC-583-1B_General_Requirements_for_Liferaft_Inspections.pdf PDF
(111)telescoping_boom_crane.pdf PDF
dwg506-_FP02_Vents_and_Sounds_System_Diagram_(2_sheets).pdf PDF
AMC-997-1A _Drydocking_and_Routine_Drydock_Work_(6_pages).pdf PDF
HB-163_FP19_Seachest_Diagram.pdf PDF
Ocean_Surveyor_Installation_Guide_PN_95A-6019-00_April_2014.pdf PDF
Navi-Sailor_NS4000_ECDIS_Version_2.00.323_Installation_Guide.pdf PDF
ABS_Drydocking_Survey.pdf PDF
SH-461-007-REV_1_CENTERBOARD_ITI_INSTALLATION_REPAIR_(3).pdf PDF
dwg528-_FP05_Grey_and_Black_Water_Sys_Diagram_(3_sheets).pdf PDF
(105)StoreHandlingCrane.pdf PDF
HB-243_FM01-001-03ab-_Shafting_Layout___Details.pdf PDF
631-3B.pdf PDF
FA03_Machinery_Arrangement.pdf PDF
(004)Anchor_Windlass_rev2.pdf PDF
FA17_Mission_Equip_and_Rigging_Arrangements.pdf PDF
(006)SternTubeBearing_and_Shaft_Seal_Resubmittal.pdf PDF
FP03_Fresh___Potable_Water_System_Diagram.pdf PDF
(048)Trawling_and_Scientific_Winch_System_Part_2.pdf PDF
(047)_Trawling_and_Scientific_Winch_System_Part_1.pdf PDF
MOC-631-2D.pdf PDF
ASHRAE_Standard_151_-_HVAC_Balancing___Testing.pdf PDF
(011)Cathodic_protection_system.pdf PDF
OD-581-03.pdf PDF
HB-085-_FA02_General_Arrangements_(6_sheets).pdf PDF
009-32_Cleanin_Painting.pdf PDF
256-_FP08_Main_SW_Cooling_System_Diagram_(3_sheets).pdf PDF
(005)Line_Shaft_and_Thrust_Bearing_Manual.pdf PDF
OD-581-002_Revision_C.pdf PDF
RFP_ATTACHMENT_J.5.pdf PDF
RFP_ATTACHMENT_J.3.pdf PDF
RFP_ATTACHMENT_J.2.pdf PDF
RFP_ATTACHMENT_J.7.pdf PDF
RFP.pdf PDF
Show all 50

DRYDOCK REPAIRS FOR NOAA SHOP PISCES has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

www.furuno.com All brand and product names are trademarks, registered trademarks or service marks of their respective holders.

MARINE RADAR/ARPA

Model FAR-2137S/2837S/2137S-BB

Installation Manual Comply with MSC.192(79)

TABLE OF CONTENTS

SAFETY INSTRUCTIONS....................... i

EQUIPMENT LISTS .............................. iii

SYSTEM CONFIGURATION.................. v

1. MOUNTING ..................................... 1-1

1.1 Antenna Unit ........................................ 1-1

1.2 Monitor Unit.......................................... 1-8

1.3 Power Supply Unit ............................. 1-12

1.4 Control Unit ........................................ 1-13

1.5 Processor Unit ................................... 1-18

2. WIRING ........................................... 2-1

2.1 Interconnection .................................... 2-1

2.2 Antenna Unit ........................................ 2-2

2.3 Monitor Unit.......................................... 2-6

2.4 Processor Unit ..................................... 2-7

2.5 Power Supply Unit ............................. 2-12

2.6 Changing AC Power Specification of

Processor Unit .................................. 2-12

3. SETTING AND ADJUSTMENT ....... 3-1

3.1 DIP Switch Setting ............................... 3-1

3.2 Monitor Unit (MU-190/MU-231)

Setting................................................. 3-2

3.3 Initializing Tuning.................................. 3-3

3.4 Heading Alignment ............................... 3-4

3.5 Adjustment Sweep Timing.................... 3-7

3.6 Suppressing Main Bang ....................... 3-8

3.7 Other Settings ...................................... 3-9

3.8 Dual Radar Display

(non IMO-type only) .......................... 3-17

4. INSTALLING OPTIONAL

EQUIPMENT........................................4-1

4.1 Gyro Converter GC-10 ......................... 4-1

4.2 Memory Card Interface Unit ................. 4-9

4.3 DVI-RGB Conversion Kit (for VDR

connection)........................................ 4-12

4.4 BNC Connector Converter ................. 4-15

4.5 Junction Box....................................... 4-16

5. INPUT/OUTPUT DATA ....................5-1

INSTALLATION MATERIALS,

ACCESSORIES, SPARE PARTS....... A-1

OUTLINE DRAWINGS ....................... D-1

INTERCONNECTION DIAGRAM....... S-1

The paper used in this manual is elemental chlorine free.

・FURUNO Authorized Distributor/Dealer

9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN

A : APR 2004.Printed in JapanAll rights reserved.

N4 : SEP . 14, 2015

Pub. No. IME-35210-N4

(MISU ) FAR-2137S/BB/2837S

0 0 0 1 7 8 6 4 9 1 1 i

Mandatory Action Prohibitive Action

WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION Indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury.

Warning, Caution

SAFETY INSTRUCTIONS

The operator and installer must read the applicable safety instructions before attempting to install or operate the equipment.

WARNING

Radio Frequency Radiation Hazard

The radar antenna emits electromagnetic radio frequency (RF) energy which can be harmful, particularly to your eyes. Never look directly into the antenna aperture from a close distance while the radar ius in operation or eexpose yourself to the transmitting antenna at a close distance. Distances at which RF radiation level of 100, 50 and 10 W/m are given in the table below.

Note: If the antenna unit is installed at a close distance in front of the wheel house, your administration may require halt of transmission within a certain sector of antenna revolution.

This is possible. Ask your FURUNO representive or dealer to provide this feature.

SN30AF: 10 ft SN36AF: 12 ft FAR-2137S: available in blackbox configuration.

Model Transceiver Magnetron Antenna 100W/m2 50W/m2 10W/m2

RTR-080

(S-30 kw) MG5223F

SN36AF 0.1 m 0.7 m 2.0 m

FAR-2137S

FAR-2837S

DANGER Indicates a potentially hazardous situation which, if not avoided, will result in death or serious injury.

Wear a safety belt and hard hat when working on the antenna unit.

Serious injury or death can result if someone falls from the radar antenna mast.

DANGER

SN30AF 0.1 m 2.4 m

*1

*1

*2

*2 ii

CAUTION

Observe the following compass safe distances to prevent deviation of a magnetic compass:

Antenna Unit (30 kw)

Standard compass

Monitor Unit (MU-201CR) 1.55 m 1.00 m

Monitor Unit (MU-231CR) 1.85 m 1.20 m

Processor Unit (RPU-013) 1.35 m 0.85 m

Control Unit (RCU-014) 0.30 m 0.30 m

Control Unit (RCU-015) 0.95 m 0.60 m

Control Unit (RCU-016) 0.65 m 0.45 m

Power Supply Unit (PSU-007)

Memory Card Interface Unit

(CU-200)

0.90 m 0.60 m

Steering compass

3.95 m 2.55 m

0.85 m 0.55 m

Switching Hub

(HUB-100)

1.00 m 0.60 m

Junction Box (RJB-001) 1.10 m 0.70 m

Be sure that the power supply is compatible with the voltage rating of the equipment.

Do not install the monitor unit, processor unit or control unit where they may get wet from rain or water splash.

Fire or damage to the equipment can result if a different cable is used.

Connection of an incorrect power supply can cause fire or damage the equipment .

Use only the specified power cable.

Water in the units can result in fire, electrical shock, or damage the equipment.

Attach securely protective earth to the ship's body.

The protective earth (grounding) is required to the AC power supply to prevent electrical shock.

Do not open the equipment unless totally familiar with electrical circuits and service manual.

Only qualified personnel should work inside the equipment.

WARNING

Construct a suitable service platform from which to install the antenna unit.

Serious injury or death can result if some-one falls from the radar antenna mast.

Turn off the power at the mains switch-board before beginning the installation.

Fire, electrical shock or serious injury can result if the power is left on or is applied while the equipment is being installed.

ELECTRICAL

SHOCK

HAZARD

Monitor Unit

(MU-190)

Monitor Unit

(MU-231)

1.65 m 1.05 m

0.85 m 0.55 m iii

EQUIPMENT LISTS

Standard Supply

Name Type Code No. Qty Remarks SN30AF - 1 Radiator

RSB-098 -

200 VAC 3φ 50 Hz, 220 VAC 3φ 60 Hz

RSB-099 -

380 VAC 3φ 50 Hz, 440 VAC 3φ 60 Hz

Antenna Chassis

RSB-100 - 220 VAC, 3φ, 50 Hz RSB-101 - 220 VAC, 3φ, 60 Hz

Antenna Unit

RSB-102 -

440 VAC, 3φ, 60 Hz

Antenna Chassis for HSC

Power Supply Unit PSU-007 - 1 MU-201CR For FAR-2137S MU-231CR For FAR-2837S MU-190 For FAR-2137S

Monitor Unit

MU-231

- 1

For FAR-2837S Processor Unit RPU-013 - 1 AC type

RCU-014 Standard type Control Unit

RCU-015

- 1

Trackball type CP03-27201 008-538-720 1 For antenna unit CP03-25700 000-080-435 15 m signal cable RW-9600 CP03-25710 000-080-436 30 m signal cable RW-9600 CP03-25720 000-080-437 50 m signal cable RW-9600

CP03-25730 000-082-191

40m signal cable RW-9600 CP03-25800 000-080-434 1 Cable assy. for monitor unit CP03-25602 008-535-940 1 For RPU-013, AC set

Installation Materials*

CP03-27301 008-538-740 1 For PSU-007 FP03-09810 008-536-010 1 For monitor unit FP03-09850 008-535-610 For RCU-014

FP03-09860 008-535-690

For RCU-015/016

Accessories*

FP03-10101 008-538-730 1 For antenna unit SP03-14404 008-535-910 1 For processor unit 100 VAC set SP03-14405 008-535-920 For processor unit 220 VAC set Spare Parts*

SP03-14401 008-535-990

For monitor unit, AC set

*: See lists at the end of this manual.

Optional Equipment Name Type Code No. Remarks

Gyro Converter GC-10-2 000-080-440 See chapter 4.

Performance Monitor PM-51 000-081-261 Mandatory for IMO radar

(Continued on the next page.)

iv

Name Type Code No. Remarks

RU-1803 -

For processor unit, 440 VAC → 100 VAC

RU-3305 -

For de-icer , 110/115/220/230 VAC

→ 100 VAC

RU-5693 -

For RSB-098/099, 110 V →220 VAC

RU-6522 -

For RSB-098/099, 220 V →200 VAC

Transformer Unit

RU-5466-1 -

For RSB-098/099, 440 V →220 VAC

Not available for HSC

Memory Card Interface Unit CU-200-FAR 000-081-568 W/CP03-27430, See chapter 4.

External Buzzer OP03-21 000-030-097 Control Unit RCU-016 000-080-299 Remote type, W/FP03-09860 RAM Card 00RAM08MC-005 004-376-740 8 MB

OP03-180-1 008-545-590 Mounted at Factory.

OP03-180-2 008-536-070 Mounted in field. See chapter 4.

OP03-180-3 008-545-610 Mounted in console at factory

DVI-RGB Conversion Kit

OP03-180-4 008-545-600 Mounted in console in filed.

XH10P-W-6P L=20M 000-149-748 20 m

XH10P-W-6P L=30M 000-149-749

Between processor and control unit 30 m

XH10P-W-5P-A L=10M 000-149-050 Between control units, 10 m XH10P-W-5P-A L=20M 000-149-051 Between control units, 20 m XH10P-W-5P-A L=30M 000-149-052 Between control units, 30 m DVI-D/D S-LINK 10M 000-150-200 Monitor-Processor, 10m S03-9-5 008-206-640 For external radar, 5 m, 8-8P S03-9-10 008-206-650 For external radar, 10 m, 8-8P

Cable Assy.

S03-9-15 008-209-160 For external radar, 15 m, 8-8P CP03-28900 000-082-658 FR-FTPC-CY 10 m CP03-28910 000-082-659 FR-FTPC-CY 20 m LAN Cable Kit (with armor) CP03-28920 000-082-660 FR-FTPC-CY 30 m

Modular connector MPS588-C, 2pcs

FP03-09820 008-535-560 Hanger assy. for MU-201CR Accessories

FP03-09830 008-536-020 Hanger assy. for MU-231CR Hand Grip FP03-09840 008-535-570 For monitor unit

03-163-1201 100-307-260 For MU-201CR Dust Cover

03-163-2101 100-307-270 For MU-231CR FP03-11500 001-020-090 For MU-201CR

Hood FP03-11000 008-571-680 For MU-231CR

Clamp Plate OP03-182 008-535-620 For RCU-014

FP03-09870 008-535-630

Flush Mount Kit

OP03-198 001-008-050

For control unit RCU-014/015/016

OP03-183 008-535-640 For RCU-014&MU-201CR OP03-184 008-535-650 For RCU-014& MU-231CR Coupling Pedestal OP03-185 008-535-660 For RCU-014

Desktop Mount Kit FP03-10201 008-539-530 For CU-200 Console Mount Kit FP03-10202 008-539-540 For CU-200 BNC connector converter DSUB-BNC-1 000-148-528 For VDR Junction Box RJB-001 - For more than 100m antenna cable Switching Hub HUB-100 - See HUB-100 Operator’s manual.

FP03-11010 001-033-140 For MU-231CR display unit Slim Hood

FP03-11510 001-034-390 For MU-201CR display unit v

SYSTEM CONFIGURATION

PROCESSOR UNIT

RPU-013(Navigator)

EPFS IEC-61162 Serial Data (Input/Output)

IEC-61162 Serial Data (Input)

Gyrocompass

AIS

Track Control Unit

: Option : Dockyard supply

: Standard

AD-100

MEMORY CARD

INTERFACE UNIT

CU-200-FAR

VDR

External Monitor

Sub Display

Alarm****

CONTROL UNIT

RCU-014

(Standard) or

RCU-015

(Trackball)

Control Unit

RCU-016

(Remote)

Transformer Unit

RU-1803

ANTENNA UNIT

Gyro Converter

GC-10

RSB-098/099

RSB-100/101/102 (for HSC)

Performance Monitor

RJB-001 **

RJB-001 **

100-230 VAC

SN30AF/

SN36AF

POWER SUPPLY

UNIT PSU-007

RU-6522

RU-5693

RU-5466-1

*: For FAR-2137S-BB, a monitor unit is prepared by user. See page 1-8. Category of Units Antenna Unit: Exposed to weather All other units: Protected from weather

Radiator

AC spec. only

Chassis

**: Used for antenna cable more than 100 m.

***: Not available for HSC spec.

Switching HUB

HUB-100

1)

SDME

Speed Log

2)

3)

****: Contact output for Alarm (Load current) 120mA, (Polarity) No.1/2: Normally Close, No.3/4: Normally Open Serial I/O for alarm is also possible, which complies with IEC 61162-1.

These monitors have been approved by the IMO, MU-190/201CR for CAT2, MU-231/231CR for CAT1. If a different monitor is to be used, its effective diameter must meet the applicable Category requirements:

CAT 1: effective diameter 320 mm or higher, CAT 2: effective diameter 250 mm or higher Refer to their operator's manuals for details.

MONITOR UNIT

MU-201CR

or

MU-190

(FAR-2137S)

MU-231CR

or

MU-231

(FAR-2837S)

1) Connect the EPFS which is approved in accordance with the requirements of the IMO in resolution MSC. 112(73) is used.

2) Connect the SDME which is approved in accordance with the requirements of the IMO in resolution MSC.96(72) is used.

3) Use the gyrocompass having an update rate that is adequate for the ship’s rate of turn.

vi

About the category sticker

This radar meets the requirements in IEC62388 (Marine navigation and radio communication equipment and systems-Shipborne radar-Performance requirements, method of testing and required test results).

Check the appropriate box on the sticker which is pre-attached on the processor unit, according to your radar’s specification. Refer to the table shown below to confirm your category.

Category Radar Type Antenna rotation speed

CAT 1 FAR-2817, FAR-2827, FAR-2837S, FAR-2827W,

FAR-2837SW

Normal speed

CAT 1H FAR-2817, FAR-2827, FAR-2837S HSC

CAT 2 FR-2117/BB, FAR-2127, FAR-2127-BB,

FAR-2137S, FAR-2137S-BB

Normal speed

CAT 2H FAR-2117, FAR-2117-BB, FAR-2127,

FAR-2127-BB, FAR-2137S, FAR-2137S-BB

HSC

1-1

1. MOUNTING

NOTICE

Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment.

Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors.

1.1 Antenna Unit

Mounting considerations

• The antenna unit is generally installed either on top of the wheelhouse, on the radar mast, or on a suitable platform. Locate the antenna unit in an elevated position to permit maximum target visibility.

• A line of sight from the antenna unit to the bow of the ship should hit the surface of the sea in not more than 500 m or twice the ship’s length, depending which value is smaller, for all load and trim conditions.

less than 500 m or twice the ship’s length

• Mount the antenna unit so that any blind sectors caused by objects (mast, etc.) are kept to a minimum. No blind sector should exist in arc of the horizon from right ahead to 22.5° aft of the beam to either side (see Figure 1 below). Also, individual blind sectors of more than 5°, or the total arc of both blind sectors of more than 20°, should not occur in the remaining arc (Figure 2). Note that any two blind sectors separated by 3° or less are regarded as one sector.

Figure 1 Figure 2 a, b, c: less than 5 respectively a+b+c+... : less than 2022.522.5 less than 3

270 90

1-2

• Install the antenna unit safely away from interfering high-power energy sources and other transmitting radio antenna.

• Keep the lower edge of the antenna unit above the safety rail by 500 mm or more.

• Two antenna units should be mounted as below:

more than 20 more than 1 m

• No funnel, mast or derrick should be within the vertical beamwidth of the antenna unit in the bow direction, especially zero degrees ±5°, to prevent blind sectors and false echoes on the radar picture.

• It is rarely possible to place the antenna unit where a completely clear view in all directions is available. Thus, you should determine the angular width and relative bearing of any shadow sectors for their influence on the radar at the first opportunity after fitting.

• Locate a direction finder antenna clear of the antenna unit to prevent interference to the direction finder. A separation of more than two meters is recommended.

• A magnetic compass will be affected if the antenna unit is placed too close to the magnetic compass. Observe the compass safe distances on page ii to prevent deviation of the magnetic compass.

• Do not paint the radiator aperture, to ensure proper emission of the radar waves.

• The antenna base is made of cast aluminum. To prevent electrolytic corrosion of the antenna base, use the seal washers and corrosion-proof rubber mat and ground the unit with the ground wire (supplied).

• Deposits and fumes from a funnel or other exhaust vent can adversely affect the aerial performance and hot gases may distort the radiator portion. The antenna unit must not be mounted where the temperature is more than 70°C.

• Leave sufficient space around the unit for maintenance and servicing. See the antenna unit outline drawing for recommended maintenance space.

1-3

Installation precaution for S-band antenna unit If an S-band antenna unit is mounted near the end of a platform to provide sufficient rotation clearance for the radiator, the antenna unit, because of its weight, swings up and down by ship’s vibration and rolling. This exerts excessive levels of stress at the base of the radiator, which can damage the radiator. To prevent this, relocate the antenna unit, or if relocation is not possible, reinforce the platform.

Mast for DF, etc.

Mount the antenna unit directly on the mast or on the platform, as near as possible to center of the mast.

Mast for DF

Remarkable vibration (pitching)

Mounting position

EXAMPLE

Mounting precaution for S-band antenna unit

1-4

Antenna unit assembling

The antenna radiator and the antenna housing are shipped in separate packages.

Assemble them as below. The antenna unit may be assembled before hosting it to the mounting platform. However, do not lift the antenna unit by the radiator.

Antenna unit assembling procedure

1. Screw the guide pins (2 pcs.) in the radiator.

2. Remove the protective cap from the choke guide and radiator.

3. Grease O-ring and set it to the groove of the choke guide.

4. Place the radiator on the radiator bracket. (Radiator direction is shown by the logo on the bracket. If reversely oriented the radiator cannot be set to the bracket.)

5. Loosely fix the radiator to the radiator bracket with hex bolts (M10x25), spring washers and flat washers.

6. Remove the guides pins and tighten hex bolts.

Radiator front

Guide pin (2 pcs.)

Arrow mark for the radiator front.

Antenna radiator

Assembling the radiator bracket

Be sure to remove the guide pins after fixing the radiator.

Injury may result if the guide pins loosen and fall.

1-5

How to lift the antenna unit

1. Fix the antenna radiator to the antenna unit chassis as shown on page 1-4.

2. Attach the lifting fixtures and collars as shown below.

3. Position the radiator as shown below and arrange the ropes A and B.

Lifting fixture

Collar for fixing

Supplied as accessories.

Remove after installation.

Hex bolt (M12x20) (Torque 63.5Nm)

Remove lifting fixture, coat threads of hex bolts with silicone grease, and then insert bolts in antenna chassis.

Lifting hook (2 pcs.)

* Protect radiator with cardboard or cloth at locations marked with asterisk.

A 2m

B 1.8m

Plat washer (M12)

Spring washer

Attachment of lifting fixtures, collar and ropes

1-6

Fastening the antenna unit to the mounting platform See the figure on the next page for antenna unit mounting.

1. Referring to the antenna outline drawing, drill eight fixing holes of 15 mm in diameter in the radar mast platform or the deck.

• The diameter of the mast for fixing the antenna unit platform must be over 250 mm.

• The thickness of the antenna unit platform must be over 15 mm.

• The reinforcement rib must be installed diagonally as shown below.

Over 15mm

250mm diameter or more, 6 mm thick or more

Use two nuts.

Ship's bow

Install the reinforcement rib diagonally.

Bottom view Installation of reinforcement ribs

2. Place the corrosion-proof rubber mat (supplied) on the mounting platform.

3. Hoist the antenna unit as shown on page 1-5 and place it on the rubber mat. Orient the cable gland toward the ship’s stern (or port, starboard). Remove the lifting fixtures and collars.

4. Fix the antenna base to the mounting platform with four M12x70 hex bolts, nuts, washers and seal washers (supplied). For the unit with the performance monitor (PM), orient the PM toward the ship’s stern.

5. Arrange the grounding terminal at the nearest grounding spot with the M6x25 hex bolt, nut and washers. Then, fix a ground wire (RW-4747, 340 mm) to the terminal.

6. Connect the other end of the ground wire to the ground terminal of the antenna unit.

7. Coast grounding terminal and fixing bolts on the antenna unit with silicone sealant

(supplied).

1-7

Seal washer

Corrosion proof rubber mat

Use two nuts.

(Torque 63.5Nm)

Coat with silicone sealant after fastening ground wire.

Ground wire

Antenna chassis

Hex bolt

OR

Ground wire

Coat with silicone sealant.

Ground wire

Welding

Hex nut

Ground terminal provided on antenna base.

Set corrosion-proof rubber mat, bolt antenna unit to mounting location, and coat exposed hardware with silicone sealant.

Arrange ground terminal as close as possible to antenna unit.

Hex bolt

Flat washer

Hex nut Spring washer Flat washer

Flat washer Spring washer

G1_1/4-A

Ground terminal

Mounting of antenna unit

1-8

1.2 Monitor Unit

The monitor unit can be flush mounted in a console panel, or mounted on a desktop using the optional accessories. For MU-190/231, see the applicable Operator’s Manual(s).

Note: FAR-2137S-BB has no monitor unit. Prepare a suitable one locally.

Recommended monitor: SXGA (1280x1024), aspect ratio 5:4

Mounting considerations When selecting a mounting location, keep in mind the following points:

• Select a location where the display unit can be viewed conveniently and where the screen can be viewed while facing towards the bow.

• Select a suitable mounting location considering the applicable distance.

• The optimal viewing distances for the radar display units are: MU-170C: 920 mm, MU-201CR: 1080 mm, MU-231CR: 1200 mm.

• Locate the unit out of direct sunlight and away from heat sources because of heat that can build up inside the cabinet.

• Locate the equipment away from places subject to water splash and rain.

• Leave sufficient space on the sides and rear of the unit to facilitate maintenance.

• A magnetic compass will be affected if the monitor unit is placed too close to the magnetic compass. Observe the compass safe distances on page ii to prevent deviation of a magnetic compass.

Mounting procedure Flush mounting

Follow the procedure below to mount the monitor unit in a console panel.

1. Make cutout in mounting location referring to the outline drawing shown below.

2. Insert the monitor unit to the hole and fix it by four tapping screws (6x30).

3. Attach panel hooks near the fixing holes (upper two locations). These are used to pull out the monitor unit from a console panel for servicing.

4. Attach four panel covers to the fixing holes.

(7 9)

4-φ8

FIXING HOLES

Monitor unit MU-201CR

506 4-FIXING HOLES

30 80

(For FAR-2137S)

± 1

506 ± 1

1-9

(7 9)

4-φ8

FIXING HOLES

Monitor unit MU-201CR

506 4-FIXING HOLES

30 80

(For FAR-2137S)

± 1

506 ± 1

4-φ8 FIXING HOLES

(9 6)

4-FIXING HOLES

30 80

Monitor unit MU-231CR (For FAR-2837S)

± 1

570 ± 1

Flush mounting of monitor unit

Panel hook

Panel cover

Fixing screw

Attaching panel hook and panel cover

Note: If you need to remove the monitor unit from the mounting panel, remove the four panel covers with your fingernail and use two panel hooks supplied as accessories to lift the monitor unit.

Desktop mounting

Use the optional accessories to mount the monitor unit on a desktop.

• For FAR-2137S: FP03-09820 (Code No.: 008-535-560)

• For FAR-2837S: FP03-09830 (Code No.: 008-536-020)

1-10

Contents of FP03-09820/09830 Name Type Code No. Qty Remarks

Hanger L 03-163-1111 100-305-141 1

Hanger R 03-163-1112 100-305-181 1

03-163-1113 100-305-191 For FAR-2137S Hanger stay

03-163-2071 100-305-371

For FAR-2837S

Hole plug CP-30-HP-13 000-160-074-10 2

Plastic rivet KB-13 Rivet Black 000-570-276-10 4

Hex. bolt M6x25 000-162-949-10 4

Hex. bolt M10x30 000-162-884-10 2

Spring washer M10 000-864-261 2

Flat washer M10 000-864-131 2

1. Assemble two hangers and hanger stay with two hex bolts (M10x30), flat washers and spring washers and cover each hex bolt with hole plug.

2. Fix the above assembly to the mounting location with four hex bolts (M12, dockyard supply).

3. Fasten the monitor unit to the mounting hanger assembly with four hex bolt (M6x25, supplied).

4. Cover each hex bolts with panel cover.

5. Cover each holes for hand grip on the hangers with plastic rivet (4 pcs).

Panel cover

Hex bolt (M6x25) (Torque 7.6Nm)

Hanger (R)Hanger stay

M12 bolts for fixing (Torque 63.5Nm) (Dockyard supply)

Hanger (L)

Hex bolt M10x30 (Torque 36.5Nm)

Plastic rivet

Hole plug Panel cover

To remove this, insert fingernail in groove.

Flat Washer M10

Spring Washer M10

Monitor Unit

1-11

The hand grip is optionally available for the desktop mounting monitor unit.

Handle

Screw M6x20 (Torque 7.6Nm)

Wave washer

Rosette washer

Hood (option)

When it is too bright in the daytime, use the optional hood to shade the screen.

• For FAR-2137S: FP03-11500 (Code No.: 001-020-090)

• For FAR-2837S: FP03-11000 (Code No.: 008-571-680)

Contents of hood Name Type Code No. Qty. Remarks

Hood (21) FP03-11501 001-020-120 1 For FAR-2137S Hood (23) FP03-11001 008-571-700 1 For FAR-2837S Fixing plate 03-163-2202-0 100-335-560-10 4 Screw M4x10 D=13 US304 000-862-543 4

1. Desktop mounting: Fasten the fixing plates to the fixing holes with the hex head bolts

(supplied).

Flush mounting: Fasten the display unit to the mounting location, and then attach the fixing plates with four self-tapping screws.

Fixing plate

Fixing hole

Hex head bolt

2. Attach the hood to the display unit (the hood is outside of the fixing plates).

3. Fasten the hood to the fixing plates with four screws supplied (M4x10).

1-12

1.3 Power Supply Unit

The Power Supply Unit PSU-007 does not contain usual operating controls. Therefore, it can be installed in any recessed place either in vertical or horizontal position. (For the console mount display unit, the PSU-007 can be installed inside the console.) However, select a dry and well-ventilated location and observe the compass safe distance to prevent deviation of a magnetic compass. See page ii.

1. Open the cover of the power supply unit.

2. Fasten the unit to chosen location with four self-tapping screws 5x20.

3. After connecting cables, attach the cover.

11 130#30 #30

CABLE ENTRY

FIXING HOLES

4- 6

1-13

1.4 Control Unit

The control unit may be mounted on a tabletop, with or without the KB fixing metal (supplied), which mounts the control unit at an angle.

Mounting considerations When selecting a mounting location, keep in mind the following points:

• Select a location where the control unit can be operated conveniently.

• Locate the unit away from heat sources because of heat that can build up inside the cabinet.

• Locate the equipment away from places subject to water splash and rain.

• Determine the mounting location considering the length of the signal cable between the control unit and the processor unit. (The signal cable comes in lengths of 10 m).

• A magnetic compass will be affected if the control unit is placed too close to the magnetic

Fixing with KB fixing plate

1. Fix the KB fixing plate to the bottom of the control unit.

2. Attach cushions (three for RCU-014, two for RCU-015/016) to the bottom of the control unit as shown below.

3. Fix it to a desired location with self-tapping screws (local supply).

CushionKB fixing plate

Side view for RCU-014/015/016

1-14

Fixing without KB fixing metal

1. Drill four mounting holes of 5 mm diameter referring to the outline drawing at the back of this manual.

2. Fix the control unit with four screws (M4) from under side of the tabletop. (The M4 screws with a sufficient length for the thickness of the tabletop should be provided locally.)

#70

308±1

6±

4-M4 (Fixing holes) (bottom)

Control Unit RCU-014

F4

F3

F2

F1

24 32

110±1

6±

4-M4 (Fixing holes)

(REAR)

RCU-015/016

Flush mounting

Use the optional flush mount kit FP03-09870 to mount the control unit RCU-014, RCU-015 and/or RCU016 to a console panel.

Name: Flush mount kit Type: FP03-09870 Code No.: 008-535-630 No. Name Type Code No. Qty

1 Mount plate 03-163-7531 100-306-261 4

2 Hex nut M5 000-863-108 4

3 Wing screw M5X40 000-162-682-10 4

4 Pan head screw M4X12 000-163-192-10 4

1-15

1. Prepare a cutout in the mounting location as shown in the figure below.

388 150

170±2 176

±2

±2

±2

For RCU-014 For RCU-015 and RCU-016

2. Set the control unit to the cutout.

3. Attach the mounting plate to the control unit with four screws from the rear side.

4. Screw the wing screw to each mounting plate and then insert hex bolt to each wing screw.

5. Fasten each wing screws and then fasten the hex nuts as shown in the figure below.

(P )#70

(P )#70

Note: P 10<=

RCU-014 RCU-015/RCU-016

1-16

To connect RCU-016 in series with RCU-014

1. Pass the cable derived from RCU-016.

2. Connect the connector of the cable to J502.

3. Clamp the copper part of the cable with the cable clamp.

Inside of RCU-014

1-17

To change the cable entry

To change the cable entry from the side (default) to the bottom, modify the unit as shown below.

Cable clamp 03-163-7804

Screw M3X8 (Torque 0.78Nm)

Screw M4X8 (Torque 1.47Nm)

2. Pull out the cable.

1. Remove the cable clamp.

3. Pass the cable from this hole.

4. In here, clamp the copper part of the cable with the cable clamp removed at step1.

J522: If you connect RCU-016 in series with RCU-015, plug in here.

Bottom of the unit

(Torque 1.47Nm)

RCU-015/016: Changing cable entry

1-18

1.5 Processor Unit

Mounting considerations When selecting a mounting location, keep in mind the following points:

• Locate the processor unit away from heat sources because of heat that can build up inside the cabinet.

• Locate the equipment away from places subject to water splash and rain.

• Leave sufficient space at the sides and rear of the unit to facilitate maintenance.

• A magnetic compass will be affected if the processor unit is placed too close to the magnetic compass. Observe the compass safe distances on page ii to prevent deviation of a magnetic compass.

Mounting procedure

1. Fix the unit with four M6 bolts, or self- tapping screws.

0±

350±1

2-φ7 FIXING HOLES

R3.5

370±1

2-FIXING NOTCH

#5

Floor mounting or bulkhead mounting

Note: If you fix the unit, cable entry upside, never remove the screw M3x10 that joints the upper case assy. and lower case assy. of the processor unit.

Screw M3X10

Upper case assy.

Lower case assy.

Never remove this screw.

Processor unit

2-1

2. WIRING

Wiring consideration

• To lessen the chance of picking up electrical interference, avoid where possible routing the signal cable near other onboard electrical equipment (radars, transmitting radio antennas, etc.) Also avoid running the cable in parallel with power cables. When crossing with other cable, the angle should be 90°to minimize the magnetic field coupling.

• The signal cable run between the antenna and processor units is available in lengths of 15 m (standard), 30 m and 50 m. Whatever length is used it must be unbroken; namely, no splicing allowed. Use the signal cable as short as possible to minimize attenuation of the signal.

• The radar should be connected to an emergency power source, as required by SOLAS

II-1.

2.1 Interconnection

Processor unit

: Cable requires fabrication

100-115 VAC/220-230 VAC

Antenna unit

TB801

TB802

Monitor unit

Control unit

RW-9600

15/30/40/50 m (Max.100 m)

DPYC-2.5

DPYC-2.5

XH10P-W-6P L=1.5/10/20/30 m

100-230 VAC

D V

I- D

/D S

IN

G

LE

LI

N K

, 5 m

/1 m

110 VAC, 3φ, 60 Hz 220 VAC, 3φ, 50 Hz 440 VAC, 3φ, 50 Hz

For HSC 220 VAC, 3φ, 50 Hz 220 VAC, 3φ, 60 Hz 440 VAC, 3φ, 60 Hz

440 VAC, 3φ, 60 Hz 380 VAC, 3φ, 50 Hz

220 VAC, 3φ, 60 Hz 200 VAC, 3φ, 50 Hz

POWER SUPPLY

UNIT PSU-007

RU-6522

RU-5693

RU-5466-1

Control unit

(RCU-016)

XH10P-W-5P-A

L=10/20/30m

F4

F3

F2

F1

T P

Y C

Y -2

.5

T P

Y C

Y -2

.5

(RCU-014 or RCU-015)

Memory card I/F unit

CU-200-FAR

*: Not available for HSC

D P

Y C

-1 .5

Junction Box

RJB-001**

Junction Box

RJB-001**

**: If the length of the antenna cable is more than 100m, use Junction box RJB-001. However, the maximum length is 300m.

Standard Interconnection

2-2

2.2 Antenna Unit

G1_1/4-A

G1-A G3/4-C

Antenna motor switch

Gland for signal cable (RW-9600) for power cableGland G1_1/4-A

Antenna unit, bow view

1. Open the right side cover on the antenna unit with the hex wrench.

2. Unfasten the cable gland for the signal cable and remove the gasket, flat washers and blind lid.

3. Fabricate the signal cable RW-9600 as follows.

a) Remove the outer sheath, armor and inner sheath as shown right.

b) Unravel the shield to expose the wires in the inner layer.

c) Shorten each core considering its location on the terminal board TB801.

d) Trim each wire (except coaxial wire) considering its location on the terminal board.

e) Trim the shield leaving 200 mm and attach crimp-on lug FV5.5-4.

f) Remove insulation of each wire by about 6 mm.

g) Fabricate the coaxial cable as shown right.

4. As shown in the figure below, slide the clamping gland, flat washer, gasket and flat washer on the signal cable.

5. Fold back armor and pass the flat washer as shown in the figure below. Cut and trim the armor around the flat washer.

Gasket Vinyl sheath

Clamping gland

Flat washer

Cut and trim armor.

Passing clamping gland, washers and gasket on the signal cable

Shield wire

Fold back shield.

Conductor

6Wire

Coaxial cable

20mm

ShieldArmorOuter sheath Inner sheath

460mm

5mm

Shield

FV5.5-4

200mm

Coaxial cable

Vinyl cable

5 914

2-3

Grounding point for the shield.

Pass the signal cable

RW-9600.

TB801

TB801

TB802

Clamp shield of coaxial cable.

TB board

Coaxial cable

Antenna unit, port side view

6. Confirm that armor is grounded between two flat washers.

7. Coat the screw part of the clamping gland with silicone sealant and tighten it.

8. Using the opener, insert each core (except coaxial cable) to appropriate connector plug on the TB801.

9. Loosen two screws and slide the TB board assembly upward and pull out it.

10. Connect the coaxial cable to TB802 on the TB board and clamp the shield with the cable clamp on the TB board.

Wiring for Coaxial cable

CAUTION

Clamp shied with bracket.

Tighten conductor with screw.

Procedures

1. Twist the conductor.

2. Press the terminal opener downward.

3. Insert the wire to hole.

4. Remove the terminal opener.

5. Pull the wire to confirm that it is ecure.

Terminal opener

Wiring for WAGO connector

WAGO connector Wire

Twist

Press downward.

Do not use crimp-on lug to prevent contact resistance from increasing.

11. Remount the TB board assembly.

12. Connect the shield wire to the grounding point as shown in the figure above.

13. Seal the cable gland with putty.

2-4

Fabricating power cable TPYCY-2.5

1. Open the left side cover on the antenna unit with the hex wrench.

2. Fabricate the cable as shown below. Use TPYCY-2.5 (Japan Industry Standard) cable or equivalent.

25 mm 5 mm

FV2-4

SheathArmorAnti-corrosive Vinyl sheath

Approx. 170 mm

Conductor

S = 2.5 mm2

∅ = 2.01 mm

Vinyl sheath

Armor

Cable TPYCY-2.5

Sheath ∅ = 15.5 mm

Fabricating the power cable TPYCY-2.5

3. At the power cable gland on the antenna unit, unfasten the clamping gland and remove gasket, flat washers and blind lid.

4. As shown in the figure below, slide the clamping gland, washers and gasket onto the power cable. Fold back the armor by 5 mm, and then pass it through the two flat washers.

Gasket Vinyl sheath

Clamping gland

Flat washer

Cut and trim armor.

Passing clamping gland, washers and gasket on power cable TPYCY-2.5

5. Coat the screw part of the clamping gland with silicone sealant and tighten it.

6. Pass the power cable behind the terminal block, and then pass it through the locking wire saddle.

7. Fix the crimp-on-lug FV2-4 (blue) to each conductor.

2-5

Terminal board for power cable Pass the power supply cable here.

Antenna unit, left view

8. Connect crimp-lug to the terminal block referring to the interconnection diagram.

9. Attach the cover (torque: 10 N·m).

10. Seal the cable gland with putty.

2-6

2.3 Monitor Unit

Two cables are terminated at the display unit: the signal cable from the processor unit (5 m or 10 m cable) and the power cable from the ship’s mains. The signal cable comes with a connector preattached to it for connection to the display unit. Fabricate the power cable as below. Use DPYC-2.5 (Japan Industry Standard) cable or the equivalent. For MU-190/231, see the applicable Operator’s Manual(s).

Fabricating the power cable

1. Cut armor of the cable by 40 mm.

2. Cut vinyl sheath by 35 mm.

3. Remove insulation of wires by about 10 mm. Fix crimp-on lugs to the conductors.

4. Peel paint of the armor by 40 mm.

5. Cover the end of armor with vinyl tape.

40 mm: Peel paint.

Taping

(a)

(b)

(d)

Armor

35 mm

10 mm

(c)

Approx. 40 mm

DPYC-xx

Conductor S = 2.5 mm φ = 2.01 mm

Armor

(sectional view)

Fabricating power cable DPYC-2.5

Cable entrance for signal cable (The connector with no EMI core should be connected to the monitor unit.)

Cable entrance for power cable

MU-201CR MU-231CR

Monitor unit (rear panel)

2-7

2.4 Processor Unit

Four cables are terminated at the processor unit: the antenna unit cable, display unit cable, control unit cable and the power cable. Cables other than the power cable come with a connector preattached to them for connection to the processor unit. Fabricate the power cable as below. For the power cable, use DPYC-2.5 (Japan Industry Standard) or the equivalent.

Note: Pass the AC line through a double-contact breaker (shipyard supply).

Fabricating the power cable

1. Cut armor of the cable by 40 mm.

2. Cut vinyl sheath by 35 mm.

3. Remove insulation of wires by about 10 mm. Fix crimp-on lugs to the cores.

4. Peel paint of the armor by 40 mm.

5. Cover the end of armor with vinyl tape.

40 mm: Peel paint.

Taping

(a)

(b)

(d)

Armor

35 mm

10 mm

(c)

Approx. 40 mm

DPYC-2.5

Fabricating power cable DPYC

2-8

Connection of cables The power cable is connected to the terminal board on the rear panel and the signal cable from the Monitor unit is connected to the DVI-D connector. Other cables are connected to the printed circuit board 03P9342.

F1

ACK

φ18.9

AIS

1 7

AD100

GYRO

PSU004

φ7.4

VDR IN

φ7

VDR OUT

24' 26

9 14 17

DC/AC

φ9 HDG

32 54 6

RSD

1918 20

Monitor unit

Network DVI-D monitor

Power cable clamp

Power cable terminal board

Remove the protection cover.

Control unit** Heading senor Speed log Navigator

Memory Card IF unit

VDR OUT

VDR IN

Gyrocompass

AD-100

AIS

Antenna unitCable clamp

GND terminal

Power cable

FUSE

F70

*: The connector side which EMI core is attached should be connected to the processor unit.

**: The configuration of optional cables between the processor unit and the control unit is as follows. Note that the cable fabrication for each end is different.

20/30 m 300 mm150 mm

Control unit Processor unit

Cable XH10P-W-6P L=20/30M

When the RCU-016 is installed, optional cable (XH10P-W-5P-A, L=10/20/30M) is required.

Cable fabrication for each end is the same.

10/20/30 m 150 mm150 mm

Control unit Control unit

XH10P-W-5P-A L=10/20/30M

2-9

Location of connectors Open the processor unit as follows and the 03P9342 board appears.

J621

J620

J619

J618

J612

J610

J608

J607

J606

J605

J604

J603

J602

J601

J617

J616

PSU

J654

J615J614

J613

Tx HV line

J609

Cable clamp

03P9342

Gyro converter board or AD-100

Speed log

Navigator

Heading sensor

Cable from control unit

PC

Cable from antenna unit

Coaxial wire

Gyro converter board

AIS

External alarm

Track control

ECDIS

Sub display*

Master radar

+ 12 V for card I/F

Sub display*

(SEMI-LOG)

(FULL-LOG)

J611

Cable from Power supply unit

03P9342

*: See page 2-11 for details.

2-10

Cable fabrication for the cables connected to the 03P9342 board

• Signal cable RW-9600 (Between antenna unit and processor unit)

ShieldArmor

Clamp here by cable clamp.

Vinyl tape After exposing cores, wind shield around the armor.

Vinyl sheath

Coaxial cable

60 450

Conductor

5 9

Coaxial cable

Fold back shield.

• Other cables for optional units Use TTYCS-1 or TTYCS-4 (Japan standard cable) or equivalent.

Conductor S = 0.75 mm φ = 1.11 mm

TTYCS-1

Armor

Shield

Sheath φ = 10.1 mm Conductor

S = 0.75 mm φ = 1.11 mm

TTYCS-4

Armor

Shield

Sheath φ = 18.5 mm

60: Peel paint.�

L

ShieldArmor

Clamp here by cable clamp.

Vinyl tape After exposing cores, wind shield around the armor.

L= Depends on equipment connected. Measure at the processor unit.

Wiring for Coaxial cable

Clamp shied with bracket.

Tighten conductor with screw.

Procedures

1. Twist the conductor.

2. Press the terminal opener downward.

3. Insert the wire to hole.

4. Remove the terminal opener.

5. Pull the wire to confirm that it is ecure.

Terminal opener

Wiring for WAGO connector

WAGO connector Wire

Twist

Press downward.

Do not use crimp-on lug to prevent contact resistance from increasing.

2-11

Connection of Sub-display

A conventional remote display and/or FAR-2107 series radar can be connected to J617 and J618 in the processor unit as a sub-display. However, the control for GAIN and STC are different depending on J617 and J618. Refer to the table to connect sub-displays.

Port Conventional remote display FAR-2107 series radar

Overall gain Even if input video level is adjusted to 4 Vp-p, the gain is 8 db lower than that on the master radar.

The gain is 8 dB lower than that on the master radar.

GAIN control

The GAIN control is effective.

The GAIN control has no effect.

J617

(FULL-LOG)

STC control The STC control is effective.

The STC control has no effect.

Overall gain When input video level is adjusted to 4 Vp-p, the gain becomes the same as that on the master radar.

The gain is almost same as that on the master radar.

GAIN control The GAIN control is effective.

The GAIN control has no effect.

J618

(SEMI-LOG)

STC control The STC control is effective, however this control is added on the signal adjusted by the master radar. So this port is not recommended to use .

The STC control has no effect.

2-12

2.5 Power Supply Unit

Wire the unit as shown in the interconnection diagram.

Relay

XK1: Connect output line.

TB1: Connect control line.

K2: Connect

Cable clamp: Clamp the armors of the cable.

input line.

Thermal relay

Power supply unit PSU-007

2.6 Changing AC Power Specification of Processor

Unit

To change AC power specification between 100 VAC and 220 VAC, add or remove jumper connector P108 on the PWR board 03P9339 and change the fuse on the processor unit according to ship’s mains as shown in the table below. The figure on the next page shows the location of the fuse and the jumper connector on the PWR board. Also, adjustment of the overvoltage detection circuit is required.

Note: To change from 220VAC to 100VAC, locally prepare the jumper connector, referring to the figure on the next page (VH8P connector housing is fitted at J108).

Power supply Fuse Jumper connector P108

100 VAC 10A Added

220 VAC 5A Removed

2-13

Cover of PWR board

Fuse

Upper part of processor unit (SPU assembly omitted)

PWR board

J104

J103

J106J105

J101

PWR board

(P)HV

AC FILP108/J108

R21

(OVER)

Jumper connector

(VH8P)

8 7 6 5 4 3 2 1

How to adjust the overvoltage detection circuit:

1. Add or remove the jumper connector P108 and change the fuse.

2. Rotate R21 fully clockwise on the PWR board.

3. Connect a variable transformer between ship's mains and the input power terminal board

TB-1 of the processor unit.

4. Adjust the variable transformer output (i.e., input voltage to the processor unit) as follows.

For 100 VAC set: 144 VAC For 220 VAC set: 288 VAC

5. Turn on the radar and rotate the R21 counterclockwise gradually until the overvoltage detection circuit functions (i.e., power supply cuts off).

6. Lower the output voltage of the variable transformer and confirm that the radar automatically turn on with a voltage lower than 142VAC or 284VAC.

7. Gradually increase the output voltage of the variable transformer and confirm that the overvoltage detection circuit functions at 144V or 288VAC of the variable transformer output.

8. Assemble and connect the processor unit.

2-14

This page is intentionally left blank.

3-1

3. SETTING AND ADJUSTMENT

3.1 DIP Switch Setting

The processor unit is shipped for model FAR-2137S. If your model is FAR-2837S/2137S-BB, change the DIP switch setting as follows.

1. Remove the top cover of the processor unit.

2. Open the SPU assembly block and remove the shield cover.

Shield cover SPU assembly block

SPU board 03P9337

DIP switch S1

3. Set the DIP switch S1 as follows.

S1 Monitor SXGA for

FAR-2137S

(Default)

Monitor UXGA for FAR-2837S (For

MU-231CR

S. No. 0269 and later)

FAR-2137S-BB

1 OFF ON OFF

2 OFF OFF ON

Not used.

Note: Set #1 and #2 of S1 to OFF for MU-231CR S. No. 0268 and earlier.

�OFF

ON

S1

3-2

3.2 Monitor Unit (MU-190/MU-231) Setting

The [INSTALLATION SETTING] menu appears only when the power is turned on for the first time after installation of the monitor unit.

INSTALLATION SETTING

EXT BRILL CTRL

SERIAL BAUDRATE

COLOR CALIBRATION

KEY LOCK

SAVE AND EXIT

RS-485

4800bps

ON

ON

YES

(OFF/DVI1/DVI2/RS-232C/RS-485/USB)

(4800/9600/19200/38400)

(OFF/ON)

(OFF/ON)

(NO/YES)

Menu

Menu item

Adjust the settings referring to the following table.

EXT BRILL

CTRL

SERIAL

BAUDRATE

COLOR

CALIBRATION

KEY LOCK DVI PWR

SYNC*2

DVI*1 - OFF ON ON

*1: To connect to the processor unit of a radar, connect the video signal cable to the DVI-D1 port. Then, select DVI1 to display the radar picture.

*2: "DVI PWR SYNC" is the slide switch at the bottom rear of the monitor unit. Confirm that this switch is set to "ON" (default setting). See "Slide switch" below for details.

Slide switch

Set the slide switch to "ON" (default setting). This setting automatically powers the monitor unit on or off according to the DVI signal input. The power switch of the monitor unit is inoperative.

Note: The OFF position provides control of the monitor unit power with the power switch of the monitor unit.

How to open the [INSTALLATION SETTING] menu

Turn off the monitor unit. While you hold the [DISP] key, press the [ /BRILL] key to turn on the monitor unit. Press and hold the [DISP] key for more than five seconds.

Note: When the "DVI PWR SYNC" slide switch is ON, turn on the connected external equipment while you press the [DISP] key to turn on the monitor unit.

3-3

[ECHO]

1 BACK

2 2ND ECHO REJ

OFF/ON

3 TUNE INITIALIZE

4 PM

OFF/ON

5 SART

OFF/ON

6 WIPER

OFF/1/2

7 ECHO AREA*

CIRCLE/WIDE/ALL

8 [PICTURE SELECT]

9 STC RANGE

+00

3.3 Initializing Tuning

1. Transmit the radar on 48 nm range and rotate the GAIN knob to show 70-80 of the gain bar.

2. Roll the trackball to choose the MENU box at the right side of the screen and then push the left button.

3. Roll the wheel to choose 1 ECHO and then push the wheel.

Bold: Default settings (Same for all menu illustrations) *: non IMO-type only.

ECHO menu

4. Roll the wheel to choose 3 TUNE INITIALIZE.

5. Push the wheel to initialize automatic tuning.

After a while, echoes appear on the screen. The message “TUNE INITIALIZE” appears in red during automatic tuning. When this message disappears, the tuning is completed. If necessary adjust the GAIN to show echoes clearly.

6. Push the right button twice to close the menu.

3-4

3.4 Heading Alignment

You have mounted the antenna unit facing straight ahead in the direction of the bow.

Therefore, a small but conspicuous target dead ahead visually should appear on the heading line (zero degrees).

In practice, you will probably observe some small bearing error on the display because of the difficulty in achieving accurate initial positioning of the antenna unit. The following adjustment will compensate for this error.

000 010 020

170180190 α Target αCorrect bearing relative to heading

Antenna mounted error to port (HDG SW advance)

Picture appears deviated clockwise.

000 010 020

170180190 β Target βApparent position of target

Antenna mounted error to starboard (HDG SW delayed)

Picture appears deviated counterclockwise.

Correct bearing relative to heading

Apparent position of target

Heading alignment

1. Select a stationary target echo at a range between 0.125 and 0.25 nm, preferably near the heading line.

2. Operate the EBL control to bisect the target echo.

3. Read the target bearing.

4. Measure the bearing of the stationary target on the navigation chart and calculate the difference between actual bearing and apparent bearing on the radar screen.

5. Press the [MENU] key to show the main menu.

6. While pressing and holding down the [HL OFF] key, press the [MENU] key five times.

3-5

7. Press [0] key to show the [INITIALIZE] menu.

[INITIALIZE]

1 BACK

2 [ECHO ADJ]

3 [SCANNER]

4 [INSTALLATION]

5 [OWN SHIP INFO]

6 [TT PRESET]

7 [NETWORK]

8 [OTHER]

9 [FACTORY]

Note: See next page to access the INITIALIZE menu with the trackball style control unit

RCU-015.

8. Press [2] key to open the [ECHO ADJ] menu.

[ECHO ADJ]

1 BACK

2 CABLE ATT ADJ

AUTO/MANUAL

3 HD ALIGN

000.0°

4 TIMING ADJ

5 MBS

6 DEFAULT ANT HEIGHT

5/7.5/10/15/20/ 25/30/35/40/45/ more 50 m

7 NEAR STC CURVE

2/2.5/3/3.5/4.2

8 MID STC CURVE

3/4/5/6

9 FAR STC CURVE

6/7/8

0 RING SUPPRESSION

ECHO ADJ menu

9. Press [3] key to choose the HD ALIGN option.

10. Key in the bearing difference. The setting range is 0 to 359.9°

11. Confirm that the target echo is displayed at correct bearing on the screen.

12. Press the [MENU] key to finish.

3-6

How to Access the Installation Mode with the RCU-015 Trackball Style Controller

1. By using the trackball, move the pointer until it highlights the MENU box as shown. DO NOT CLICK the menu box, just leave the arrow over the menu.

2. Press and hold down the F1 key. Keep it held down during the next step.

3. Then, click on the right controller button 5 times.

You should hear a “triple Beep” on the fifth press.

The INITIALIZE menu will appear. Click on INSTALLATION to access the installation menus.

3-7

3.5 Adjustment Sweep Timing

Sweep timing differs with respect to the length of the signal cable between the antenna unit and the processor unit. Adjust sweep timing at installation to prevent the following symptoms:

• The echo of a “straight” target (for example, pier), on the 0.25 m range, will appear on the display as being pulled inward or pushed outward. See Figure below.

• The range of target echoes will also be incorrectly shown.

(1) Correct (2) Target pushed (3) Target pushed inward outward

Examples of correct and incorrect sweep timings

1. Transmit on the 0.25 nm range.

2. Adjust radar picture controls to display picture properly.

3. Select a target echo which should be displayed straightly.

4. Press [4] key to choose the [TIMMING ADJ] on the [ECHO ADJ] menu.

[ECHO ADJ]

1 BACK

2 CABLE ATT ADJ

AUTO/MANUAL

3 HD ALIGN

000.0°

4 TIMING ADJ

5 MBS

6 DEFAULT ANT HEIGHT

5/7.5/10/15/20/ 25/30/35/40/45/ more 50 m

7 NEAR STC CURVE

2/2.5/3/3.5/4.2

8 MID STC CURVE

3/4/5/6

9 FAR STC CURVE

6/7/8

0 RING SUPPRESSION

5. Rotate the wheel to set a suitable value which causes the target to be displayed straightly. The setting range is 0 to 4095.

6. Press the [MENU] key to finish.

3-8

3.6 Suppressing Main Bang

If main bang appears at the screen center, suppress it as follows.

1. Transmit the radar on a long range and then wait ten minutes.

2. Adjust gain to show a slight amount of noise on the display.

3. Select the 0.25 nm range. Adjust sea clutter to suppress.

4. Press [5] key to choose the MBS on the [ECHO ADJ] menu.

[ECHO ADJ]

1 BACK

2 CABLE ATT ADJ

AUTO/MANUAL

3 HD ALIGN

000.00

4 TIMING ADJ

5 MBS

6 DEFAULT ANT HEIGHT

5/7.5/10/15/20/ 25/30/35/40/45/ more 50 m

7 NEAR STC CURVE

2/2.5/3/3.5/4.2

8 MID STC CURVE

3/4/5/6

9 FAR STC CURVE

6/7/8

0 RING SUPPRESSION

5. Rotate the wheel to set a suitable value so that the main bang disappears. The setting range is 0 to 255.

6. Press the [MENU] key to finish.

3-9

3.7 Other Settings

ECHO menu setting Open the [ECHO ADJ] menu as described on page 3-3.

[ECHO ADJ]

1 BACK

2 CABLE ATT ADJ

AUTO/MANUAL

3 HD ALIGN

000.0°

4 TIMING ADJ

5 MBS

6 DEFAULT ANT HEIGHT

5/7.5/10/15/20/ 25/30/35/40/45/ more 50 m

7 NEAR STC CURVE

2/2.5/3/3.5/4.2

8 MID STC CURVE

3/4/5/6

9 FAR STC CURVE

6/7/8

0 RING SUPPRESSION

To close the menu, press the [MENU] key.

CABLE ATT ADJ

Before adjusting, set the radar as follows:

IR: 2, ES: off, EAV: off, 24nm range, long pulse (Same as default setting of PICTURE1) To adjust the cable attenuation manually, choose MANUAL by pressing [2] and the [ENTER] key, and then rotate the wheel so…