AMC-583-1B_General_Requirements_for_Liferaft_Inspections.pdf

PDF 26 KB Posted

Attached to
DRYDOCK REPAIRS FOR NOAA SHOP PISCES
Solicitation number
EA-133M-16-RP-0112
Issued by

View the file

Other files

File Type Posted
Amendment_0002.pdf.pdf PDF
AMC-000-3C.pdf PDF
Amendment_0001.pdf PDF
(134)Knuckle_Boom_Crane.pdf PDF
(035)FoodServiceEquipment.pdf PDF
(015)chillwaterplant.pdf PDF
634-1B_DECK_COVERINGS.pdf PDF
AMC-505-1B _Valve_Overhaul_and_Test_(4_pages).pdf PDF
HB-524-_FP21_Egg_Sampling_System_Diagram_(1_sheet)_(1).pdf PDF
(105)StoreHandlingCrane.pdf PDF
HB-243_FM01-001-03ab-_Shafting_Layout___Details.pdf PDF
HB-631_FF04_Paint_Schedule.pdf PDF
AMC-000-2C.pdf PDF
631-3B.pdf PDF
FA03_Machinery_Arrangement.pdf PDF
(071)Rudder.pdf PDF
dwg529-_FP01_Bilge_and_Ballast_System_Diagram_(2_sheets).pdf PDF
FV01-000-01_(HVAC_Loads) AS-BUILT_2006-09-14)ab.pdf PDF
256-_FP08_Main_SW_Cooling_System_Diagram_(3_sheets).pdf PDF
MOC-631-2D _Coating_Systems_for_Steel_Surfaces.pdf PDF
FP16_Chilled_Water_System_Diagram.pdf PDF
Consilium_SAL_T2 _System_Description_Labels_and_Drawings_No._703280B1.pdf PDF
FA-05_Fire_Control_Plan.pdf PDF
RC18XX_FUSA_GMDSS_Installation_Manual_(FS1575_FS2575 _FM8900 _FELCOM18).pdf PDF
HB-512-_FV02_HVAC_Diagram.pdf PDF
dwg582-_FH20_Anchor_Storage___Handling_Layout___Details _sheet_1.pdf PDF
FP07_Compressed_Air_System_Diagram.pdf PDF
(111)telescoping_boom_crane.pdf PDF
dwg506-_FP02_Vents_and_Sounds_System_Diagram_(2_sheets).pdf PDF
HB-163_FP19_Seachest_Diagram.pdf PDF
AMC-997-1A _Drydocking_and_Routine_Drydock_Work_(6_pages).pdf PDF
Ocean_Surveyor_Installation_Guide_PN_95A-6019-00_April_2014.pdf PDF
163-_FP19_Seachest_Diagram _Rev_6_(1_sheet).pdf PDF
dwg524-_FP18_Scientific_SW_System_Diagram_(2_sheets).pdf PDF
6001_Table_1_US_Standard_Bus_Connection_Bolt_Torque_Values.pdf PDF
FA04_Docking_Drawing.pdf PDF
Consilium_SAL_T2_and_SAL_T2 _Speed_Logs_System_Manual_Article_No._702270L2.pdf PDF
Navi-Sailor_NS4000_ECDIS_Version_2.00.323_Installation_Guide.pdf PDF
dwg085-_FA01_Outboard_Profile.pdf PDF
(008)Bow_Thruster.pdf PDF
ABS_Drydocking_Survey.pdf PDF
SH-461-007-REV_1_CENTERBOARD_ITI_INSTALLATION_REPAIR_(3).pdf PDF
Consilium_SAL_T2_Spare_Parts_List_T2_Bottom_Part_Spares.pdf PDF
Furuno_Operators_Manual.pdf PDF
amc-000-1f.pdf PDF
dwg100-_FH02_Hull_Forebody_Scantlings_FR_0-_FR_18_(7_sheets).pdf PDF
dwg524-_FP23_Aux_Seawater_Cooling_System_Diagram_(2_sheets).pdf PDF
(085)fuel_oil_purifier.pdf PDF
AMC-300-1 _Overhaul_of_Electrical_Rotating_Machinery_(10_pages).pdf PDF
IME-35190-P2.pdf PDF
Show 40 more

Latest 50 of 77 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMC-583-1B

DECEMBER 1998

SUPERSEDING

AMC-583-1A

JULY 1995

NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION (NOAA)

ATLANTIC MARINE CENTER

STANDARD SPECIFICATION AMC-583-1B

GENERAL REQUIREMENTS FOR LIFERAFT INSPECTIONS

1. SCOPE. This specification contains the general requirements and procedures to be used for performing U.S. Coast Guard inspections on NOAA liferafts and hydraulic releases.

2. REFERENCE.

(a) Code of Federal Regulations Title 46, Part 160, section 151, "Inflatable Liferafts (SOLAS)"

(b) Code of Federal Regulations Title 46, Part 160, Section 062, "Releases. Lifesaving Equipment, Hydraulic, and Manual."

3. REQUIREMENTS.

3.1. General. The following requirements apply to all work.

3.1.1. Except as otherwise specified, the contractor shall

provide all labor, material, services, tools, supervision, and technical expertise needed to accomplish the work required by this specification.

3.1.2. All work shall be performed by an authorized service

facility of the liferaft manufacturer.

3.1.3. Provide and install parts and components during

servicing of the liferafts as required by this specification, the Detail Specification, and other procurement documents. Renewal of other parts and components determined to be needed, as a result of servicing the liferafts will be negotiated by the Contracting Officer as an additional cost to the purchase order or contract. Provide a list of renewal parts and components which have not reached their expiration date to the COTR for disposition.

3.1.4. The Contractor shall remove all the ocean liferafts and associated hydraulic releases from the ship to the contractors facility for inspection.

3.1.5. Service the liferaft in accordance with reference (a)

and this specification.

3.1.6. Stamp the metal inspection plate in accordance with

reference (a).

3.1.7. Reinstall all liferafts and hydraulic releases in their original locations.

3.2. Annual Inspection. Perform an annual U.S. Coast Guard

inspection on the required ocean liferafts in accordance with reference (a). Renew or provide the following items as part of the inspection:

3.2.1. All bands.

3.2.2. All clips.

3.2.3. All required instruction labels.

3.2.4. All certifications (including U.S. Coast Guard) for

inspected items.

3.2.5. Deleted.

3.2.6. All flashlight batteries.

3.2.7. All repair kit cement.

3.2.8. A report for each liferaft with a cost breakdown for

all renewed items and an inventory of all dated items with their expiration date.

3.3. Special Five-Year Inspection. In addition to the above

annual inspection, perform a five-year U.S. Coast Guard inspection on the required ocean liferafts in accordance with reference (a). In addition to all renewals identified in reference (a), provide a CO2 recharge of the inflation cylinder with certification of the cylinder’s weight prior to and after the two week stand period as part of the inspection.

3.4. Hydraulic Release Inspection. Perform an annual U.S. Coast Guard inspection on all hydraulic releases in accordance with reference (b).

4. NOTES.

4.1. The following information will be provided by the Detail Specification or other procurement document:

4.1.1. The quantity, capacity, and manufacturer of each

liferaft being serviced.

4.1.2. The location of each liferaft being services.

4.1.3. The type of servicing (annual inspection or special

five-year inspection) required for each of the liferafts being serviced.

4.1.4. The quantity and manufacturer of the hydraulic

releases being serviced.

END OF SPECIFICATION