IME-35190-P2.pdf

PDF 19 MB Posted

Attached to
DRYDOCK REPAIRS FOR NOAA SHOP PISCES Federal contract opportunity
Solicitation number
EA-133M-16-RP-0112
Issued by
Department of Commerce National Oceanic and Atmospheric Administration

View the file

Other files for this federal contract opportunity

Other files attached to DRYDOCK REPAIRS FOR NOAA SHOP PISCES, newest first.
File Type Posted
Amendment_0002.pdf.pdf PDF
Amendment_0001.pdf PDF
(134)Knuckle_Boom_Crane.pdf PDF
(035)FoodServiceEquipment.pdf PDF
FV01-000-01_(HVAC_Loads) AS-BUILT_2006-09-14)ab.pdf PDF
dwg529-_FP01_Bilge_and_Ballast_System_Diagram_(2_sheets).pdf PDF
dwg524-_FP18_Scientific_SW_System_Diagram_(2_sheets).pdf PDF
dwg085-_FA01_Outboard_Profile.pdf PDF
(008)Bow_Thruster.pdf PDF
Consilium_SAL_T2_Spare_Parts_List_T2_Bottom_Part_Spares.pdf PDF
(085)fuel_oil_purifier.pdf PDF
AMC-300-1 _Overhaul_of_Electrical_Rotating_Machinery_(10_pages).pdf PDF
HB-631_FF04_Paint_Schedule.pdf PDF
(071)Rudder.pdf PDF
256-_FP08_Main_SW_Cooling_System_Diagram_(3_sheets).pdf PDF
MOC-631-2D _Coating_Systems_for_Steel_Surfaces.pdf PDF
RC18XX_FUSA_GMDSS_Installation_Manual_(FS1575_FS2575 _FM8900 _FELCOM18).pdf PDF
FP16_Chilled_Water_System_Diagram.pdf PDF
HB-512-_FV02_HVAC_Diagram.pdf PDF
dwg582-_FH20_Anchor_Storage___Handling_Layout___Details _sheet_1.pdf PDF
Consilium_SAL_T2 _System_Description_Labels_and_Drawings_No._703280B1.pdf PDF
FA-05_Fire_Control_Plan.pdf PDF
163-_FP19_Seachest_Diagram _Rev_6_(1_sheet).pdf PDF
Consilium_SAL_T2_and_SAL_T2 _Speed_Logs_System_Manual_Article_No._702270L2.pdf PDF
FA04_Docking_Drawing.pdf PDF
6001_Table_1_US_Standard_Bus_Connection_Bolt_Torque_Values.pdf PDF
Furuno_Operators_Manual.pdf PDF
dwg100-_FH02_Hull_Forebody_Scantlings_FR_0-_FR_18_(7_sheets).pdf PDF
amc-000-1f.pdf PDF
dwg524-_FP23_Aux_Seawater_Cooling_System_Diagram_(2_sheets).pdf PDF
FP07_Compressed_Air_System_Diagram.pdf PDF
AMC-583-1B_General_Requirements_for_Liferaft_Inspections.pdf PDF
(111)telescoping_boom_crane.pdf PDF
dwg506-_FP02_Vents_and_Sounds_System_Diagram_(2_sheets).pdf PDF
AMC-997-1A _Drydocking_and_Routine_Drydock_Work_(6_pages).pdf PDF
HB-163_FP19_Seachest_Diagram.pdf PDF
Ocean_Surveyor_Installation_Guide_PN_95A-6019-00_April_2014.pdf PDF
Navi-Sailor_NS4000_ECDIS_Version_2.00.323_Installation_Guide.pdf PDF
ABS_Drydocking_Survey.pdf PDF
SH-461-007-REV_1_CENTERBOARD_ITI_INSTALLATION_REPAIR_(3).pdf PDF
IME-35210-N4.pdf PDF
dwg528-_FP05_Grey_and_Black_Water_Sys_Diagram_(3_sheets).pdf PDF
RFP_ATTACHMENT_J.5.pdf PDF
RFP_ATTACHMENT_J.3.pdf PDF
RFP_ATTACHMENT_J.2.pdf PDF
RFP_ATTACHMENT_J.7.pdf PDF
RFP_ATTACHMENT_J.6.pdf PDF
RFP_ATTACHMENT_J.1.pdf PDF
RFP_ATTACHMENT_J.4.pdf PDF
New_PKZIP_File.zip ZIP file
Show all 50

DRYDOCK REPAIRS FOR NOAA SHOP PISCES has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Comply with MSC.192(79) www.furuno.com All brand and product names are trademarks, registered trademarks or service marks of their respective holders.

MARINE RADAR/ARPA

FAR-2117/2127/2817/2827

FAR-2117-BB/2127-BB

Installation Manual

TABLE OF CONTENTS

SAFETY IINSTRUCTIONS ..................... i

EQUIPMENT LISTS ............................... iii

SYSTEM CONFIGURATION ................. vi

1. MOUNTING ..................................... 1-1

1.1 Antenna Unit ................................. 1-1

1.2 Monitor Unit .................................. 1-6

1.3 Control Unit ................................ 1-10

1.4 Processor Unit ............................ 1-15

2. WIRING ........................................ 2-1

2.1 Interconnection ............................. 2-1

2.2 Antenna Unit ................................. 2-2

2.3 Monitor Unit .................................. 2-6

2.4 Processor Unit .............................. 2-7

2.5 Changing AC Power Specification of

Processor Unit .......................... 2-12

3. SETTING AND ADJUSTMENT .... 3-1

3.1 DIP Switch Setting ....................... 3-1

3.2 Monitor Unit (MU-190/MU-231)

Setting .......................................... 3-2

3.3 Initializing Tuning .......................... 3-3

3.4 Heading Alignment ....................... 3-4

3.5 Adjustment Sweep Timing ............ 3-7

3.6 Suppressing Main Bang ................... 3-8

3.7 Other Settings .............................. 3-9

3.8 Dual Radar Display

(non IMO-type only) .................. 3-17

4. INSTALLING OPTIONAL

EQUIPMENT ................................ 4-1

4.1 Gyro Converter GC-10 ................. 4-1

4.2 Memory Card Interface Unit.............. 4-9

4.3 DVI-RGB Conversion Kit

(for VDR connection) .................. 4-12

4.4 Performance Monitor PM-31 ...... 4-15

4.5 BNC Connector Converter ......... 4-17

4.6 Junction Box ............................... 4-18

5. INPUT/OUTPUT DATA ................ 5-1

INSTALLATION MATERIALS,

ACCESSORIES,SPARE PARTS ........ A-1

OUTLINE DRAWINGS ...................... D-1

INTERCONNECTION DIAGRAMS ... S-1

The paper used in this manual is elemental chlorine free.

・FURUNO Authorized Distributor/Dealer

9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN

A : JAN 2004.Printed in JapanAll rights reserved.

P2 : SEP . 14, 2015

Pub. No. IME-35190-P2

(MISU ) FAR-2117/27/2817/27

0 0 0 1 7 5 3 2 3 1 2 i

Mandatory Action Prohibitive Action

WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION Indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury.

Warning, Caution

SAFETY INSTRUCTIONS

The operator and installer must read the applicable safety instructions before attempting to install or operate the equipment.

WARNING

Radio Frequency Radiation Hazard

The radar antenna emits electromagnetic radio frequency (RF) energy which can be harmful, particularly to your eyes. Never look directly into the antenna aperture from a close distance while the radar ius in operation or eexpose yourself to the transmitting antenna at a close distance. Distances at which RF radiation level of 100, 50 and 10 W/m are given in the table below.

Note: If the antenna unit is installed at a close distance in front of the wheel house, your administration may require halt of transmission within a certain sector of antenna revolution.

This is possible. Ask your FURUNO representive or dealer to provide this feature.

* : XN12AF: 4 ft, XN20AF: 6.5 ft, XN24AF: 8 ft

Model Transceiver Magnetron Antenna 100W/m2 50W/m2 10W/m2

XN-12AF 0.3 m 1.2m 3.7 m XN-20AF 0.1 m 0.7 m 2.2 m XN-24AF 0.1 m 0.4 m 1.5 m XN-12AF 0.9 m 2.6 m 9.0 m XN-20AF 0.5 m 1.7 m 4.6 m XN-24AF 0.2 m 1.0 m 3.3 m

MAF1565N

RTR-078A

(X-12 kw)FAR-2817/2117

FAR-2827/2127 RTR-079A

(X-25 kw) MG5436

DANGER Indicates a potentially hazardous situation which, if not avoided, will result in death or serious injury.

Wear a safety belt and hard hat when working on the antenna unit.

Serious injury or death can result if someone falls from the radar antenna mast.

DANGER

ii

Be sure that the power supply is compatible with the voltage rating of the equipment.

Do not install the monitor unit, processor unit or control unit where they may get wet from rain or water splash.

Fire or damage to the equipment can result if a different cable is used.

Connection of an incorrect power supply can cause fire or damage the equipment .

Use only the specified power cable.

Water in the units can result in fire, electrical shock, or damage the equipment.

Attach securely protective earth to the ship's body.

The protective earth (grounding) is required to the AC power supply to prevent electrical shock.

CAUTION

Observe the following compass safe distances to prevent deviation of a magnetic compass:

Antenna Unit (12 kw)

Standard compass

2.15 m 1.40 m

Antenna Unit (25 kw) 2.05 m 1.30 m

Monitor Unit (MU-201CR) 1.55 m 1.00 m

Monitor Unit (MU-231CR) 1.85 m 1.20 m

Processor Unit (RPU-013) 1.35 m 0.85 m

Control Unit (RCU-014) 0.30 m 0.30 m

Control Unit (RCU-015) 0.95 m 0.60 m

Control Unit (RCU-016) 0.65 m 0.45 m

Memory Card Interface Unit

(CU-200)

0.90 m 0.60 m

Steering compass

Switching Hub (HUB-100) 1.00 m 0.60 m

Junction Box (RJB-001) 1.10 m 0.70 m

Do not open the equipment unless totally familiar with electrical circuits and service manual.

Only qualified personnel should work inside the equipment.

WARNING

Construct a suitable service platform from which to install the antenna unit.

Serious injury or death can result if some-one falls from the radar antenna mast.

Turn off the power at the mains switch-board before beginning the installation.

Fire, electrical shock or serious injury can result if the power is left on or is applied while the equipment is being installed.

ELECTRICAL

SHOCK

HAZARD

Monitor Unit

(MU-190)

Monitor Unit

(MU-231)

1.65 m 1.05 m

0.85 m 0.55 m iii

EQUIPMENT LISTS

Standard Supply

Name Type Code No. Qty Remarks

Antenna Unit

XN12AF-RSB096-078A -

FAR-2117/2117-BB/2817, 24 rpm, 1200 mm, W/CP03-24201

XN12AF-RSB097-078A -

FAR-2117/2117-BB/2817, 42 rpm, 1200 mm, W/CP03-24201

XN20AF-RSB096-078A -

FAR-2117/2117-BB/2817, 24 rpm, 2000 mm, W/CP03-19101

XN20AF-RSB097-078A -

FAR-2117/2117-BB/2817, 42 rpm, 2000 mm, W/CP03-19101

XN24AF-RSB096-078A -

FAR-2117/2117-BB/2817, 24 rpm, 2400 mm, W/CP03-19101

XN24AF-RSB097-078A -

FAR-2117/2117-BB/2817, 42 rpm, 2400 mm, W/CP03-19101

XN12AF-RSB096-079A -

FAR-2127/2127-BB/2827, 24 rpm, 1200 mm, W/CP03-24201

XN12AF-RSB097-079A -

FAR-2127/2127-BB/2827, 42 rpm, 1200 mm, W/CP03-24201

XN20AF-RSB096-079A -

FAR-2127/2127-BB/2827, 24 rpm, 2000 mm, W/CP03-19101

XN20AF-RSB097-079A -

FAR-2127/2127-BB/2827, 42 rpm, 2000 mm, W/CP03-19101

XN24AF-RSB096-079A -

FAR-2127/2127-BB/2827, 24 rpm, 2400 mm, W/CP03-19101

XN24AF-RSB097-079A -

FAR-2127/2127-BB/2827, 42 rpm, 2400 mm, W/CP03-19101

Monitor Unit

MU-201CR

- 1

For FAR-2117/2127 MU-231CR For FAR-2817/2827 MU-190 For FAR-2117/2127 MU-231 For FAR-2817/2827

Processor Unit RPU-013 - 1

Control Unit

RCU-014

- 1 Standard type

RCU-015 Trackball type

Installation Materials

CP03-25601 008-535-550 1 For antenna unit

CP03-25700 000-080-435

15 m signal cable RW-9600 CP03-25710 000-080-436 30 m signal cable RW-9600 CP03-25720 000-080-437 50 m signal cable RW-9600 CP03-25730 000-082-191 40 m signal cable RW-9600 CP03-25800 000-080-434 1 Cable assy. for monitor unit

CP03-25602 008-535-940

For RPU-013, AC set

CP03-25603 008-535-950 For RPU-013, DC set

Accessories FP03-09810 008-536-010 1 For monitor unit

FP03-09850 008-535-610

For RCU-014

FP03-09860 008-535-690 For RCU-015/016 iv

Optional Equipment Name Type Code No. Remarks

Gyro Converter GC-10-2 000-080-440 See chapter 4.

Performance Monitor PM-31 000-080-438 Mandatory for IMO radar

Transformer Unit

RU-1803 -

Converts 440 VAC to 100 VAC, for processor unit

RU-3305 -

Converts 110/115/220/230 VAC to 100 VAC, for de-icer

Rectifier

RU-3424 -

115/230 VAC to 24 VDC, for processor unit (25 kW)

RU-1746B-2 -

115/230 VAC to 24 VDC, for processor unit (12 kW)

RU-3423 -

100/110/115/220/230 VAC to 24 VDC, for monitor unit

Memory Card Interface Unit CU-200-FAR 000-081-568 W/CP03-27430, See chapter 4.

External Buzzer OP03-21 000-030-097 Control Unit RCU-016 - Remote type, W/FP03-09860 RAM Card 00RAM08MC-005 004-376-740 8 MB

DVI-RGB Conversion Kit

OP03-180-1 008-545-590 Mounted at factory OP03-180-2 008-536-070 Mounted in field. See chapter 4.

OP03-180-3 008-545-610 Mounted in console at factory.

OP03-180-4 008-545-600 Mounted in console in field.

Cable Assy.

XH10P-W-6P L=20M 000-149-748 20 m Between control & processor unit XH10P-W-6P L=30M 000-149-749 30 m

XH10P-W-5P-A

L=10M

000-149-050 10 m

Between control units

XH10P-W-5P-A

L=20M

000-149-051 20 m

XH10P-W-5P-A

L=30M

000-149-052 30 m

DVI-D/D S-LINK 10M 000-150-200 10 m Monitor-Processor S03-9-5 008-206-640 For external radar, 5 m, 8-8P S03-9-10 008-206-650 For external radar, 10 m, 8-8P S03-9-15 008-209-160 For external radar, 15 m, 8-8P

Spare Parts

SP03-12501 008-485-360 1 For antenna unit

SP03-14404 008-535-910

For processor unit 100 VAC set

SP03-14405 008-535-920 For processor unit 220 VAC set SP03-14406 008-535-930 For processor unit 24 VDC set

SP03-14401 008-535-990

For monitor unit AC set

SP03-03900 000-081-063

For monitor unit, DC set, MU-201CR

SP03-14402 008-536-000

For monitor unit, DC set, MU-231CR v

LAN Cable Kit (with armor)

OP03-28900 000-082-658

FR-FTPC-CY

10 m Modular connection

MPS588-C,

2 pcs.

OP03-28910 000-082-629

FR-FTPC-CY

20 m

OP03-28920 000-082-660

FR-FTPC-CY

30 m

Accessories FP03-09820 008-535-560 Hanger assy. for MU-201CR FP03-09830 008-536-020 Hanger assy. for MU-231CR

Hand Grip FP03-09840 008-535-570 For monitor unit

Dust Cover 03-163-1201 100-307-260 For MU-201CR 03-163-2101 100-307-270 For MU-231CR

Hood FP03-11500 001-020-090 For MU-201CR FP03-11000 008-571-680 For MU-231CR

Clamp Plate OP03-182 008-535-620 For RCU-014

Flush Mount Kit FP03-09870 008-535-630 For control unit

RCU-016/014/015 OP03-198 001-008-050

Coupling Pedestal OP03-183 008-535-640 For RCU-014&MU-201CR OP03-184 008-535-650 For RCU-014& MU-231CR OP03-185 008-535-660 For RCU-014

BNC Connector Converter DSUB-BNC-1 000-148-528 For VDR

Junction Box RJB-001 - For more than 100m antenna cable

Desktop Mount Kit FP03-10201 008-539-530 For CU-200 Console Mount Kit FP03-10202 008-539-540 For CU-200 Switching Hub HUB-100 - See manual of HUB-100.

Slim Hood FP03-11010 001-033-140 For MU-231CR display unit

FP03-11510 001-034-390 For MU-201CR display unit

About the category sticker This radar meets the requirements in IEC62388 (Marine navigation and radiocommunication equipment and systems – Shipborne radar – Performance requirements, method of testing and required test results)

Check the appropriate box on the sticker which is pre-attached on the processor unit, according to your radar’s specification. Refer to the table shown below to confirm your category.

Category Radar type ANT. rotation speed

CAT 1

FAR-2817, FAR-2827, FAR-2837S,

FAR-2827W, FAR-2837SW

Normal speed

CAT 1H FAR-2817, FAR-2827, FAR-2837S HSC

CAT 2

FR-2117/BB, FAR-2127/BB,

FAR-2137S/BB

Normal speed

CAT 2H

FAR-2117/BB, FAR-2127/BB,

FAR-2137S/BB

HSC

vi

SYSTEM CONFIGURATION

PROCESSOR UNIT

RPU-013

EPFS

(Navigator) IEC-61162 Serial Data

(Input/Output)

IEC-61162 Serial Data (Input)

SDME

(Speed Log)

Gyrocompass

AIS

Track Control Unit

: Option : Dockyard supply

: Standard

Rectifier

RU-3424

RU-1746B-2

AD-100

MEMORY CARD

INTERFACE UNIT

CU- 200-FAR

VDR

External Monitor

Sub Display

Alarm***

MONITOR UNIT

MU-201CR,

MU-190

(2117/2127) or

MU-231CR,

MU-231

(2817/2827)

CONTROL UNIT

RCU-014

(Standard) or

RCU-015

(Trackball)

Control Unit

RCU-016

(Remote)

Transformer Unit

RU-1803

FAR-2117/2817: XN12AF-RSB-096-078A

XN12AF-RSB-097-078A

XN20AF-RSB-096-078A

XN20AF-RSB-097-078A

XN24AF-RSB-096-078A

XN24AF-RSB-097-078A

FAR-2127/2827: XN12AF-RSB-096-079A

XN12AF-RSB-097-079A

XN20AF-RSB-096-079A

XN20AF-RSB-097-079A

XN24AF-RSB-096-079A

XN24AF-RSB-097-079A

ANTENNA UNIT

Gyro Converter

GC-10

DC spec AC spec

Performance Monitor

JB

JB

24 VDC

or

100-230 VAC

100/110/115

220/230 VAC

RU-3423

24 VDC

Category of Units Antenna Unit: Exposed to weather All other units: Protected from weather

Switching HUB

HUB-100

1)

2)

3)

1) Connect the EPFS which is approved in accordance with the requirements of the IMO in resolution MSC.112(73) is used.

2) Connect the SDME which is approved in accordance with the requirements of IMO in resolution MSC.96(72) is used.

3) Use the gyrocompass having an update rate that is adequate for the ship’s rate of turn.

*: For FAR-2117-BB/2127-BB a monitor unit is prepared by user. See page 1-6.

These monitors have been approved by the IMO, MU-201CR for CAT 2, MU-231CR for CAT 1. If a different monitor is to be used, its effective diameter must meet the applicable Category requirements: CAT 1: effective diameter 320 mm or higher, CAT 2: effective diameter 250 mm or higher. Refer to their operator’s manuals for details.

**: Junction boxes are required for more than 100 m antenna cable.

***: Contact output for Alarm

(Load current) 120 mA (Polarity) No.1, 2: Normally Close, No.3, 4: Normally Open Serial I/O for alarm is also possible, which complies with IEC 61162-1.

1-1

1. MOUNTING

NOTICE

Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment.

Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors.

1.1 Antenna Unit

Mounting considerations

• The antenna unit is generally installed either on top of the wheelhouse or on the radar mast, on a suitable platform. Locate the antenna unit in an elevated position to permit maximum target visibility.

• A line of sight from the antenna unit to the bow of the ship should hit the surface of the sea in not more than 500 m or twice the ship’s length, depending which value is smaller, for all load and trim conditions.

less than 500 m or twice the ship’s length

• Mount the antenna unit so that any blind sectors caused by objects (mast, etc.) are kept to a minimum. No blind sector should exist in arc of the horizon from right ahead to 22.5° aft of the beam to either side (see Figure 1 below). Also, individual blind sectors of more than 5°, or the total arc of both blind sectors of more than 20°, should not occur in the remaining arc (Figure 2). Note that any two blind sectors separated by 3° or less are regarded as one sector.

Figure 1 Figure 2 a, b, c: less than 5 respectively a+b+c+... : less than 2022.522.5 less than 3

270 90

1-2

• Install the antenna unit away from interfering high-power energy sources and other transmitting radio antenna.

• Keep the lower edge of the antenna unit above the safety rail by 500 mm or more.

• Two antenna units should be mounted as below:

more than 20 more than 1 m

• No funnel, mast or derrick should be within the vertical beamwidth of the antenna unit in the bow direction, especially zero degrees ±5°, to prevent blind sectors and false echoes on the radar picture.

• It is rarely possible to place the antenna unit where a completely clear view in all directions is available. Thus, you should determine the angular width and relative bearing of any shadow sectors for their influence on the radar at the first opportunity after fitting.

• Locate a direction finder antenna clear of the antenna unit to prevent interference to the direction finder. A separation of more than two meters is recommended.

• A magnetic compass will be affected if the antenna unit is placed too close to the magnetic compass. Observe the compass safe distances on page ii to prevent deviation of the magnetic compass.

• Do not paint the radiator aperture, to ensure proper emission of the radar waves.

• The antenna base is made of cast aluminum. To prevent electrolytic corrosion of the antenna base, use the seal washers and corrosion-proof rubber mat and ground the unit with the ground wire (supplied).

• Deposits and fumes from a funnel or other exhaust vent can adversely affect the aerial performance and hot gases may distort the radiator portion. The antenna unit must not be mounted where the temperature is more than 55°C.

• Leave sufficient space around the unit for maintenance and servicing. See the antenna unit outline drawing for recommended maintenance space.

1-3

Assembling the antenna unit The antenna unit consists of the antenna radiator and the antenna unit chassis, and they are packed separately. Fasten the antenna radiator to the antenna unit chassis as follows:

1. For the XN20AF, XN24AF, attach two guide pins to the underside of the antenna radiator.

2. Remove the waveguide cap from the radiator bracket. The cap may be discarded.

3. Coat the waveguide flange with anticorrosive sealant as shown below.

Anticorrosive sealant

10 mm O-ring Waveguide cap

5 mm

Hole for a guide pin

Hole for a guide pin

Coating the waveguide flange with anticorrosive sealant

4. Coat fixing holes for the antenna radiator with anticorrosive sealant.

5. Grease the O-ring and set it to the O-ring groove of the radiator flange.

6. Set the antenna radiator to the radiator bracket.

7. Coat hex bolts M8x40 (for XN-20AF or XN-24AF) or hex bolt M8x35/ flat washer/spring washer (for XN-12AF) with anticorrosive sealant and use them to loosely fasten the antenna radiator to the antenna unit chassis.

8. Remove two guide pins (inserted at step 1), and then tighten fixing bolts.

CAUTION

Be sure to remove the guide pins.

Injury may result if the guide pins loosen and fall.

1-4

O-ring

Radiator bracket

Waveguide

Antenna radiator

Hex bolt (M8x40), 8 pcs.

(XN20AF, XN24AF)

Hex. bolt (M8x35), 8 pcs.

Flat washer Spring washer (XN12AF)

Guide pin

(XN20AF,

XN24AF

only)

Fastening the radiator to the radiator bracket Fastening the antenna unit to the mounting platform The antenna unit may be assembled before hoisting it to the mounting platform. However, do not lift the antenna unit by the radiator. Always hold the unit by its housing. When using a crane or hoist, lift the unit by the hoist rings which should be fastened to the bolt fixing covers of the antenna housing.

NOTICE

NO!

- To hoist antenna unit aboard vessel, attach ropes to lifting fixtures and hoist unit with crane.

- To remove load from radiator when hoisting, the length of the rope between the radiator base and the hook on the should be at least 130 cm.

- To keep the rope away from the radiator, turn the radiator and chassis approx. 30 degrees as shown below.

- Be sure to remove the lfiting fixtures after hoisting is completed.

130cm

Approx.

30 deg.

Lifting fixture

Lifting fixture Crane

(Top view)

NO!

1. Construct a suitable mounting platform referring to the outline drawing at the end of this manual.

2. Drill four mounting holes of 15 mm diameter and one cable entry hole of about 50 mm diameter in the mounting platform.

3. Lay the rubber mat (supplied) on the mounting platform.

4. Place the antenna unit on the rubber mat, orienting the unit so the bow mark on its base is facing the ship’s bow.

1-5

Ground terminal

Rubber mat

Bow mark

Antenna unit, front view

5. Fasten the antenna unit to the mounting platform with M12x60 hex bolts, nuts, flat washers and seal washers.

6. Using hex bolt (M6x25), nut (M6) and flat washer (M6), establish the ground system on the mounting platform as shown below. The location should be within 340 mm of the ground terminal on the antenna unit. Connect the ground wire (RW-4747, 340 mm, supplied) between the grounding point and ground terminal on the antenna unit. Coat the entire ground system with silicone sealant (supplied).

Anticorrosive sealant

Anticorrosive sealant

Anticorrosive sealant

Anticorrosive sealant

Anticorrosive sealant

Anticorrosive sealant

Hex bolt Spring washer

Spring washer

Spring washer

Hex nut

Hex nut

Ground wire

Ground wire

Ground wire

Ground terminal

OR

Flat washer

Hex bolt welded to ship’s superstructure

Seal washer

Rubber mat

Antenna base

How to mount the antenna unit

1-6

1.2 Monitor Unit

The monitor unit can be flush mounted in a console panel, or mounted on a desktop using the optional accessories. For MU-190/231, see the applicable Operator’s Manual(s).

Note: FAR-2117-BB/2127-BB have no monitor unit. Prepare a suitable monitor locally.

Recommended monitor: SXGA (1280x1024), aspect ratio 5:4

Mounting considerations When selecting a mounting location, keep in mind the following points:

• Select a location where the display unit can be viewed conveniently and where the screen can be viewed while facing towards the bow.

• The optimal viewing distances for the radar display units are: MU-170C: 920 mm, MU-201CR: 1080 mm, MU-231CR: 1200 mm. Select a suitable mounting location considering the applicable distance.

• Locate the unit out of direct sunlight and away from heat sources because of heat that can build up inside the cabinet.

• Locate the equipment away from places subject to water splash and rain.

• Leave sufficient space on the sides and rear of the unit to facilitate maintenance.

• A magnetic compass will be affected if the monitor unit is placed too close to the magnetic compass. Observe the compass safe distances on page ii to prevent deviation of a magnetic compass.

Mounting procedure Flush mounting

Follow the procedure below to mount the monitor unit in a console panel.

1. Make cutout in mounting location referring to the outline drawing shown below.

2. Insert the monitor unit to the hole and fix it with four tapping screws (6x30).

3. Attach panel hooks near the fixing holes (upper part). See next page. These are used to pull out the monitor unit from a console panel for servicing.

4. Attach four panel covers to the fixing holes.

(7 9)

4-φ8

FIXING HOLES

Monitor unit MU-201CR

4-FIXING HOLES

30 80

506±1

6±

(For FAR-2117/2127)

±1

6±

1-7

4-φ8 FIXING HOLES

(9 6)

4-FIXING HOLES

30 80

Monitor unit MU-231CR

570±1

3±

(For FAR-2817/2827)

3±

±1

Flush mounting of monitor unit

Panel hook

Panel cover

Fixing screw

Attaching panel hook and panel cover

Note: If you need to remove the monitor unit from the mounting panel, remove the four panel covers with your fingernail and use two panel hooks supplied as accessories to lift the monitor unit.

1-8

Desktop mounting

Use the optional accessories to mount the monitor unit on a desktop.

• For FAR-2117/2127: FP03-09820 (Code No.: 008-535-560)

• For FAR-2817/2827: FP03-09830 (Code No.: 008-536-020) Contents of FP03-09820/09830

Name Type Code No. Qty Remarks

Hanger L 03-163-1111 100-305-141 1

Hanger R 03-163-1112 100-305-181 1

Hanger stay 03-163-1113 100-305-191

For FAR-2117/2127

03-163-2071 100-305-371 For FAR-2817/2827

Hole plug CP-30-HP-13 000-160-074-10 2

Plastic rivet KB-13 Rivet Black 000-570-276-10 4

Hex. bolt M6x25 000-162-949-10 4

Hex. bolt M10x30 000-162-884-10 2

Spring washer M10 000-864-261 2

Flat washer M10 000-864-131 2

1. Assemble two hangers and hanger stay with two hex bolts (M10x30), flat washers and spring washers and cover each hex bolt with hole plug.

2. Fix the above assembly to the mounting location with four hex bolts (M12, dockyard supply).

3. Fasten the monitor unit to the mounting hanger assembly with four hex bolt (M6x25, supplied).

4. Cover each hex bolts with panel cover.

5. Cover each holes for hand grip on the hangers with plastic rivets (4 pcs).

1-9

Panel cover

Hex bolt (M6x25)

Hanger (R)Hanger stay

M12 bolts for fixing (Dockyard supply)

Hanger (L)

Hex bolt M10x30

Plastic rivet

Hole plug Panel cover

To remove this, insert fingernail in groove.

Flat Washer M10

Spring Washer M10

Monitor Unit

The hand grip is optionally available for the desktop mounting monitor unit.

Handle

Screw

Wave washer

Rosette washer

Hood (option)

When it is too bright in the daytime, use the optional hood to shade the screen.

• For FAR-2117/2127: FP03-11500 (Code No.: 001-020-090)

• For FAR-2817/2827: FP03-11000 (Code No.: 008-571-680)

Contents of hood Name Type Code No. Qty. Remarks

Hood (21) FP03-11501 001-020-120 1 For FAR-2117/2127 Hood (23) FP03-11001 008-571-700 1 For FAR-2817/2827 Fixing plate 03-163-2202-0 100-335-560-10 4 Screw M4x10 D=13 US304 000-862-543 4

1-10

1. Desktop mounting: Fasten the fixing plates to the fixing holes with the hex head bolts (supplied).

Flush mounting: Fasten the display unit to the mounting location, and then attach the fixing plates with four self-tapping screws.

Fixing plate

Fixing hole

Hex head bolt

2. Attach the hood to the display unit (the hood is outside of the fixing plates).

3. Fasten the hood to the fixing plates with four screws supplied (M4x10).

1.3 Control Unit

The control unit may be mounted on a desktop, with or without the KB fixing metal (supplied), which mounts the control unit at an angle.

Mounting considerations When selecting a mounting location, keep in mind the following points:

• Select a location where the control unit can be operated conveniently.

• Locate the unit away from heat sources because of heat that can build up inside the cabinet.

• Locate the equipment away from places subject to water splash and rain.

• Determine the mounting location considering the length of the signal cable between the control unit and the processor unit. (The 10m signal cable is attached to the control unit).

• A magnetic compass will be affected if the control unit is placed too close to the magnetic

1-11

Fixing with KB fixing plate

1. Fix the KB fixing plate to the bottom of the control unit.

2. Attach cushions (three for RCU-014, two for RCU-015/016) to the bottom of the control unit as shown below.

3. Fix it to a desired location with self-tapping screws (local supply).

CushionKB fixing plate Side view for RCU-014/015/016

Fixing without KB fixing metal

1. Drill four mounting holes of 5 mm diameter referring to the outline drawing at the back of this manual.

2. Fix the control unit with four screws (M4) from under side of the desktop. (The M4 screws with a sufficient length for the thickness of the desktop should be provided locally.)

#70

308±1

6±

4-M4 (Fixing holes) (bottom)

Control Unit RCU-014

F4

F3

F2

F1

24 32

110±1

6±

4-M4 (Fixing holes)

(REAR)

RCU-015/016

1-12

Flush mounting

Use the optional flush mount kit FP03-09870 to mount the control unit RCU-014, RCU-015 and/or RCU016 to a console panel.

Name: Flush mount kit Type: FP03-09870 Code No.: 008-535-630 No. Name Type Code No. Qty

1 Mount plate 03-163-7531 100-306-261 4

2 Hex nut M5 000-863-108 4

3 Wing screw M5x40 000-162-682-10 4

4 Pan head screw M4x12 000-163-192-10 4

1. Prepare a cutout in the mounting location as shown in the figure below.

388 150±2

170±2 176±2

±2

For RCU-014 For RCU-015 and RCU-016

2. Set the control unit to the cutout.

3. Attach the mounting plate to the control unit with four screws from the rear side.

4. Screw the wing screw to each mounting plate and then insert hex bolt to each wing screw.

5. Fasten each wing screw and then fasten the hex nuts as shown in the figure below.

(P )#70

(P )#70

Note: P 10<=

RCU-014 RCU-015/RCU-016

1-13

To connect RCU-016 in series with RCU-014

1. Pass the cable derived from RCU-016.

2. Connect the connector of the cable to J502.

3. Clamp the copper part of the cable with the cable clamp.

Inside of RCU-014

1-14

To change the cable entry

To change the cable entry from the side (default) to the bottom, modify the unit as shown below.

Cable clamp 03-163-7804

J524

J521

Screw M3x8

Screw M4x8

2. Pull out the cable.

1. Remove the cable clamp.

3. Pass the cable from this hole.

4. In here, clamp the copper part of the cable with the cable clamp removed at step1.

J522: If you connect RCU-016 in series with RCU-015, plug in here.

Bottom of the unit

RCU-015/016: Changing cable entry

1-15

1.4 Processor Unit

Mounting considerations When selecting a mounting location, keep in mind the following points:

• Locate the processor unit away from heat sources because of heat that can build up inside the cabinet.

• Locate the equipment away from places subject to water splash and rain.

• Leave sufficient space at the sides and rear of the unit to facilitate maintenance.

• A magnetic compass will be affected if the processor unit is placed too close to the magnetic compass. Observe the compass safe distances on page ii to prevent deviation of a magnetic compass.

Mounting procedure

1. Fix the unit with four M6 bolts, or self-tapping screws.

0±

350±1

2-φ7 FIXING HOLES

R3.5

370±1

2-FIXING NOTCH

#5

Floor mounting or bulkhead mounting

Note: If you fix the unit, cable entry upside, never remove the screw M3x10 that joints the upper case assy. and lower case assy. of the processor unit.

M3x10

Upper case assy.

Lower case assy.

Never remove this screw.

Processor unit

1-16

This page is intentionally left blank.

2-1

2. WIRING

Wiring consideration

• To lessen the chance of picking up electrical interference, avoid where possible routing the signal cable near other onboard electrical equipment (radars, transmitting radio antennas, etc.) Also avoid running the cable in parallel with power cables. When crossing with other cable, the angle should be 90°to minimize the magnetic field coupling.

• The signal cable run between the antenna and processor units is available in lengths of 15 m (standard), 30 m and 50 m. Whatever length is used it must be unbroken; namely, no splicing allowed. Use the signal cable as short as possible to minimize attenuation of the signal.

• The radar should be connected to an emergency power source, as required by SOLAS

II-1.

2.1 Interconnection

: Cable requires fabrication

24 VDC or

100-115 VAC/220-230 VAC

Antenna unit

TB801

TB802

Monitor unit

Control unit (RCU-014 or RCU-015)

Control unit

(RCU-016)

RW-9600

15/30/40/50 m (Max.100 m)

DPYC-2.5

XH10P-W-5P-A

L=10/20/30m

DPYC-2.5 for AC set DPYC-6 for DC set

Memory Card

I/F Unit

CU-200-FAR

XH10P-W-6P L=1.5/10/20/30m*

24 VDC or

100-230 VAC

D V

I- D

/D S

IN

G

LE

L

IN

K

M

, 5 /1 m

F4

F3

F2

F1

Junction Box

RJB-001*

Junction Box

RJB-001*

*: If the length of the antenna cable is more than 100m, use Junction box RJB-001. However, the maximum length is 300m.

Standard Interconnection

2-2

2.2 Antenna Unit

NOTE

Transceiver module (magnetron inside)

Height more than 5 cm

Non-ferrous block

The magnetron in the transceiver module will de-magnetize if it contacts ferrous material. When dismounting the transceiver module, lay it on its side or on top of non-ferrous material as shown below.

1. Open the rear cover of the antenna unit

2. Disconnect plugs P823, P803, P831 and P921. If the PM-31 is installed, also disconnect plug P911.

3. Unfasten two bolts and remove the transceiver module.

Fixing bolts

Transceiver module

Antenna unit, rear view

4. Unfasten the four fixing bolts from the cable gland at the base of the antenna unit.

Remove clamping ring, rubber gasket and washers.

5. Pass the signal cable through the cable entry hole in the antenna unit mounting platform.

Trim the cable so about 80 cm of it protrudes past the cable gland.

2-3

Antenna unit, front view, cover removed

6. Fabricate the signal cable RW-9600 as shown below.

a) Remove the outer vinyl sheath, by about 500 mm, then armor and inner sheath by about 470mm.

b) Unravel the shield to expose the core wires.

c) Trim each core wire (except coaxial wire) considering its location on the terminal board.

d) Trim the shield leaving about 500 mm and attach crimp-on lug FV5.5-4 (yellow, φ4).

e) Remove insulation of each wire by about 6 mm.

7. Slide a washer, and fold back armor.

Slide a washer, rubber gasket, washer, and clamping ring in order.

Cut the armor around the washer so it is level with the washer.

Vinyl sheath

Shield

500mm

Shield Fold back shield.

Conductor

14 5 9

Coaxial cable

30mm

ShieldArmor sheath

2-4

8. Nip the armor between two washers, and trim the excess armor from around washers.

And then pass the shield between the clamping ring and the washer as shown below.

Fasten the clamping ring with the screws.

4-M4x16

Shield

Rubber gasket (25B)

Washer

Clamping ring

Armor

Signal cable entrance

9. Connect the signal cable to the terminal board TB801 and TB802 on the RFTB board

03P9349 by referring to the interconnection diagram. Keep “slack” in the coaxial wire to prevent breakage. Insert the cores (except coaxial wire) to the connector with the opener.

1. Insert opener.

2. Push opener.

3. Insert a core.

4. Release opener.

Opener

Clamp the coaxial wire with cable clamp on the board 03P9349 as shown below.

Clamp shield with bracket.

Tighten conductor with screw.

10. Bind cable cores with cable ties.

2-5

11. Set the transceiver module to the antenna unit, push it in until it stops, and then tighten fixing bolts (4 pcs.). Connect plugs P823, P803, P831, P921 and J911 (if installed).

Fasten the shield wire to the wing nut on the transceiver module.

CAUTION

Push in transceiver unit until it stops.

Failure to do so may cause leakage of microwaves.

03P9349

Bow mark

Connector plug

Clamp for coaxial cable

Connect coaxial cable here.

Signal cable

Cable clamp for antenna cable

Transceiver module

Connect shield wire to with wing nut at the opposite side of the transceiver module.

Antenna unit, front view

12. Confirm that all screws are tightened and all wiring is properly made. Confirm that waterproofing gasket, bolts and tapping holes of antenna unit are coated with silicone grease. Close the antenna unit cover (torque: 10 N·m).

2-6

2.3 Monitor Unit

Two cables are terminated at the display unit: the signal cable from the processor unit (5 m or 10 m cable) and the power cable from the ship’s mains. The signal cable comes with a connector preattached to it for connection to the monitor unit. Fabricate the power cable as below. Use DPYC-2.5 (Japan Industry Standard) cable or the equivalent.

For MU-190/231, see the applicable Operator’s Manual(s).

Fabricating the power cable

1. Cut armor of the cable by 40 mm.

2. Cut vinyl sheath by 35 mm.

3. Remove insulation of wires by about 10 mm. Fix crimp-on lugs to the cores.

4. Peel paint of the armor by 40 mm.

5. Cover the end of armor with vinyl tape.

40 mm: Peel paint.

Taping

(a)

(b)

(d)

Armor

35 mm

10 mm

(c)

Approx. 40 mm

DPYC-2.5

Vinyl sheath

Conductor S = 2.5 mm φ = 2.01 mm

Armor

(sectional view)

Fabricating power cable DPYC-2.5

Cable entrance for signal cable (The connector with no EMI core should be connected to the monitor unit.)

Cable entrance for power cable

MU-201CR MU-231CR

Monitor unit (rear panel)

2-7

2.4 Processor Unit

Four cables are terminated at the processor unit: the antenna unit cable, display unit cable, control unit cable and the power cable. Cables other than the power cable come with a connector preattached to them for connection to the processor unit. Fabricate the power cable as below. For the power cable, use DPYC-2.5 (Japan Industry Standard) cable for AC unit or DPYC-6 for DC unit, or the equivalent.

Note: For AC unit

Pass the AC line through a double-contact breaker (shipyard supply).

Fabricating the power cable

1. Cut armor of the cable by 40 mm.

2. Cut vinyl sheath by 35 mm.

3. Remove insulation of wires by about 10 mm. Fix crimp-on lugs to the cores.

4. Peel paint of the armor by 40 mm.

5. Cover the end of armor with vinyl tape.

40 mm: Peel paint.

Taping

(a)

(b)

(d)

Armor

35 mm

10 mm

(c)

Approx. 40 mm

DPYC-2.5

Vinyl sheath

Conductor of DPYC-2.5 S = 2.5 mm φ = 2.01 mm

Armor

(sectional view)

Conductor of DPYC-6 S = 6.0 mm φ = 3.12 mm

Fabricating power cable DPYC

2-8

Connection of cables The power cable is connected to the terminal board on the rear panel and the signal cable from the monitor unit is connected to the DVI-D connector. Other cables are connected to the printed circuit board 03P9342.

F1

ACK

φ18.9

AIS

1 7

AD100

GYRO

PSU004

φ7.4

VDR IN

φ7

VDR OUT

24’ 26

9 14 17

DC/AC

φ9 HDG

32 54 6

RSD

1918 20

Monitor unit

Network DVI-D monitor

Power cable clamp

Power cable terminal board

Remove the protection cover.

Control unit** Heading senor Speed log Navigator

Memory Card IF unit

VDR OUT

VDR IN

Gyrocompass

AD-100

AIS

Antenna unitCable clamp

GND TERMINAL

Power cable

FUSE

F70

*: The connector with EMI core should be connected to the processor unit.

**: The configuration of optional cable between the processor unit and the control unit is as follows. Note that the cable fabrication for each end is different.

1.5/20/30 m 300 mm150 mm

Control unit Processor unit

Cable XH10P-W-6P L=20/30M

When the RCU-016 is installed, optional cable (XH10P-W-5P-A, L=10/20/30M) is required.

Cable fabrication for each end is the same.

10/20/30 m 150 mm150 mm

Control unit Processor unit

XH10P-W-5P-A L=10/20/30M

2-9

Location of connectors Open the processor unit as follows and the 03P9342 board appears.

J621

J620

J619

J618

J612

J610

J608

J607

J606

J605

J604

J603

J602

J601

J617

J616

PSU

External alarm

J654

J615J614

J613

Tx HV line

J609

Cable clamp

03P9342

Gyro converter board or AD-100

Speed log

Navigator

Heading sensor

Cable from the control unit

PC

Cable from antenna unit

Coaxial wire

Gyro converter board

Track control

ECDIS

To Sub display *

To Sub display *

From Master radar

+12V for card I/F

AIS

(SEMI-LOG)

(FULL-LOG)

J611

03P9342

*: See page 2-11 for details.

2-10

Cable fabrication for the cables connected to the 03P9342 board

• Signal cable RW-9600 (Between antenna unit and processor unit)

ShieldArmor

Clamp here by cable clamp.

Vinyl tape After exposing cores, wind shield around the armor.

Vinyl sheath

Coaxial cable

60 450

Conductor

5 9

Coaxial cable

Fold back shield.

• Other cables for optional units Use TTYCS-1 or TTYCS-4 (Japan standard cable) or equivalent.

Conductor S = 0.75 mm φ = 1.11 mm

TTYCS-1

Armor

Shield

Sheath φ = 10.1 mm Conductor

S = 0.75 mm φ = 1.11 mm

TTYCS-4

Armor

Shield

Sheath φ = 16.3 mm

60: Peel paint.

L

ShieldArmor

Clamp here by cable clamp.

Vinyl tape After exposing cores, wind shield around the armor.

L= Depends on equipment connected. Measure at the processor unit.

Wiring for Coaxial cable

CAUTION

Clamp shied with bracket.

Tighten conductor with screw.

Procedures

1. Twist the conductor.

2. Press the terminal opener downward.

3. Insert the wire to hole.

4. Remove the terminal opener.

5. Pull the wire to confirm that it is ecure.

Terminal opener

Wiring for WAGO connector

WAGO connector Wire

Twist

Press downward.

Do not use crimp-on lug to prevent contact resistance from increasing.

2-11

Connection of Sub-display

A conventional remote display and/or FAR-2107 series radar can be connected to J617 and J618 in the processor unit as a sub-display. However, the control for GAIN and STC are different depending on J617 and J618. Refer to the table to connect sub-displays.

Port Conventional remote display FAR-2107 series radar

J617

(FULL-LOG)

Overall gain Even if input video level is adjusted to 4 Vp-p, the gain is 8 db lower than that on the master radar.

The gain is 8 dB lower than that on the master radar.

GAIN control

The GAIN control is effective.

The GAIN control has no effect.

STC control The STC control is effective.

The STC control has no effect.

J618

(SEMI-LOG)

Overall gain When input video level is adjusted to 4 Vp-p, the gain becomes the same as that on the master radar.

The gain is almost same as that on the master radar.

GAIN control The GAIN control is effective.

The GAIN control has no effect.

STC control The STC control is effective, however this control is added on the signal adjusted by the master radar. So this port is not recommended to use.

The STC control has no effect.

2-12

2.5 Changing AC Power Specification of Processor

Unit

To change AC power specification between 100 VAC and 220 VAC, add or remove jumper connector P108 on the PWR board 03P9339 and change the fuse on the processor unit according to ship’s mains as shown in the table below. The figures below and on the next page show the location of the fuse and the jumper connector on the PWR board. Also, adjustment of the overvoltage detection circuit is required.

Note: To change from 200 VAC to 100 VAC, locally prepare the jumper connector, referring to the figure shown on the next page (VH8P connector housing is fitted at J108).

Power supply Fuse Jumper connector

100 VAC 10A Added

220 VAC 5A Removed

Cover of PWR board

Fuse

Upper part of processor unit (SPU assembly omitted)

PWR board

2-13

J104

J103

J106J105

J101

PWR board

(P)HV

AC FILP108/J108

R21

(OVER)

8 7 6 5 4 3 2 1

Jumper connector

(VH8P)

How to adjust the overvoltage detection circuit:

1. Add or remove the jumper connector P108 and change the fuse.

2. Rotate R21 fully clockwise on the PWR board.

3. Connect a variable transformer between ship's mains and the input power terminal board

TB-1 of the processor unit.

4. Adjust the variable transformer output (i.e., input voltage to the processor unit) as follows.

For 100 VAC set: 144 VAC For 220 VAC set: 288 VAC

5. Turn on the radar and rotate the R21 counterclockwise gradually until the overvoltage detection circuit functions (i.e., power supply cuts off).

6. Lower the output voltage of the variable transformer and confirm that the radar automatically turn on with a voltage lower than 142VAC or 284VAC.

7. Gradually increase the output voltage of the variable transformer and confirm that the overvoltage detection circuit functions at 144V or 288VAC of the variable transformer output.

8. Assemble and connect the processor unit.

2-14

3-1

3. SETTING AND ADJUSTMENT

3.1 DIP Switch Setting

The processor unit is shipped for model FAR-2117 or FAR-2127. If your model is FAR-2817/2827/2117-BB/2127-BB, change the DIP switch setting as follows.

1. Remove the top cover of the processor unit.

2. Open the SPU assembly block.

Shield cover SPU assembly block

SPU board 03P9337

DIP switch S1

3. Set the DIP switch S1 as follows.

S1 Monitor SXGA for

FAR-2117, 2127

(Default)

Monitor UXGA for

FAR2817, 2827

(MU-231CR

S. No. 0269 and later)

FAR-2117-BB

FAR-2127-BB

1 OFF ON OFF

2 OFF OFF ON

3 Not used. 4

Note: Set #1 and #2 of S1 to OFF for MU-231CR S. No. 0268 and earlier.

OFF

ON

S1

3-2

3.2 Monitor Unit (MU-190/MU-231) Setting

The [INSTALLATION SETTING] menu appears only when the power is turned on for the first time after installation of the monitor unit.

INSTALLATION SETTING

EXT BRILL CTRL

SERIAL BAUDRATE

COLOR CALIBRATION

KEY LOCK

SAVE AND EXIT

RS-485

4800bps

ON

ON

YES

(OFF/DVI1/DVI2/RS-232C/RS-485/USB)

(4800/9600/19200/38400)

(OFF/ON)

(OFF/ON)

(NO/YES)

Menu

Menu item

Adjust the settings referring to the following table.

EXT BRILL

CTRL

SERIAL

BAUDRATE

COLOR

CALIBRATION

KEY LOCK DVI PWR

SYNC*2

DVI*1 - OFF ON ON

*1: To connect to the processor unit of a radar, connect the video signal cable to the DVI-D1 port. Then, select DVI1 to display the radar picture.

*2: "DVI PWR SYNC" is the slide switch at the bottom rear of the monitor unit. Confirm that this switch is set to "ON" (default setting). See "Slide switch" below for details.

Slide switch

Set the slide switch to "ON" (default setting). This setting automatically powers the monitor unit on or off according to the DVI signal input. The power switch of the monitor unit is inoperative.

Note: The OFF position provides control of the monitor unit power with the power switch of the monitor unit.

How to open the [INSTALLATION SETTING] menu

Turn off the monitor unit. While you hold the [DISP] key, press the [ /BRILL] key to turn on the monitor unit. Press and hold the [DISP] key for more than five seconds.

Note: When the "DVI PWR SYNC" slide switch is ON, turn on the connected external equipment while you press the [DISP] key to turn on the monitor unit.

3-3

[ECHO]

1 BACK

2 2ND ECHO REJ

OFF/ON

3 TUNE INITIALIZE

4 PM

OFF/ON

5 SART

OFF/ON

6 WIPER

OFF/1/2

7 ECHO AREA*

CIRCLE/WIDE/ALL

8 [PICTURE SELECT]

9 STC RANGE

+00

3.3 Initializing Tuning

1. Transmit the radar on 48 nm range and rotate the GAIN knob to show 70-80 of the gain bar.

2. Roll the trackball to choose the MENU box at the right side of the screen and then push the left button.

3. Roll the wheel to choose 1 ECHO and then push the wheel.

Bold: Default settings (Same for all menu illustrations)

*: non IMO-type only

ECHO menu

4. Roll the wheel to choose 3 TUNE INITIALIZE.

5. Push the wheel to initialize automatic tuning.

After a while, echoes appear on the screen. The message “TUNE INITIALIZE” appears in yellow during automatic tuning. When this message disappears, the tuning is completed. If necessary adjust the GAIN to show echoes clearly.

6. Push the right button twice to close the menu.

3-4

3.4 Heading Alignment

You have mounted the antenna unit facing straight ahead in the direction of the bow.

Therefore, a small but conspicuous target dead ahead visually should appear on the heading line (zero degrees).

In practice, you will probably observe some small bearing error on the display because of the difficulty in achieving accurate initial positioning of the antenna unit. The following adjustment will compensate for this error.

000 010 020

170180190 α Target αCorrect bearing relative to heading

Antenna mounted error to port (HDG SW advance)

Picture appears deviated clockwise.

000 010 020

170180190 β Target βApparent position of target

Antenna mounted error to starboard (HDG SW delayed)

Picture appears deviated counterclockwise.

Correct bearing relative to heading

Apparent position of target

Heading alignment

1. Select a stationary target echo at a range between 0.125 and 0.25 nm, preferably near the heading line.

2. Operate the EBL control to bisect the target echo.

3-5

3. Read the target bearing.

4. Measure the bearing of the stationary target on the navigation chart and calculate the difference between actual bearing and apparent bearing on the radar screen.

5. Press the [MENU] key to show the main menu.

6. While pressing and holding down the [HL OFF] key, press the [MENU] key five times.

7. Press the [0] key to show the [INITIALIZE] menu.

[INITIALIZE]

1 BACK

2 [ECHO ADJ]

3 [SCANNER]

4 [INSTALLATION]

5 [OWN SHIP INFO]

6 [TT PRESET]

7 [NETWORK]

8 [OTHER]

9 [FACTORY]

Note: See next page to access the INITIALIZE menu with the trackball style control unit

RCU-015.

8. Press the [2] key to open the [ECHO ADJ] menu.

[ECHO ADJ]

1 BACK

2 CABLE ATT ADJ

AUTO/MANUAL

3 HD ALIGN

000.0°

4 TIMING ADJ

5 MBS

6 DEFAULT ANT HEIGHT

5/7.5/10/15/20/ 25/30/35/40/45/ more 50 m

7 NEAR STC CURVE

2/2.5/3/3.5/4.2

8 MID STC CURVE

3/4/5/6

9 FAR STC CURVE

6/7/8

0 RING SUPPRESSION

ECHO ADJ menu

9. Press the [3] key to choose the HD ALIGN option.

10. Key in the bearing difference. The setting range is 0 to 359.9°.

11. Confirm that the target echo is displayed at correct bearing on the screen.

12. Press the [MENU] key to finish.

3-6

How to Access the Installation Mode with the RCU-015 Trackball Style Controller

1. By using the trackball, move the pointer until it highlights the MENU box as shown. DO NOT CLICK the menu box, just leave the arrow over the menu.

2. Press and hold down the F1 key. Keep it held down during the next step.

3. Then, click on the right controller button 5 times.

You should hear a “triple Beep” on the fifth press.

The INITIALIZE menu will appear. Click on INSTALLATION to access the installation menus.

3-7

3.5 Adjustment Sweep Timing

Sweep timing differs with respect to the length of the signal cable between the antenna unit and the processor unit. Adjust sweep timing at installation to prevent the following symptoms:

• The echo of a “straight” target (for example, pier), on the 0.25 m range, will appear on the display as being pulled inward or pushed outward. See Figure below.

• The range of target echoes will also be incorrectly shown.

(1) Correct (2) Target pushed (3) Target pushed inward outward

Examples of correct and incorrect sweep timings

1. Transmit on the 0.25 nm range.

2. Adjust radar picture controls to display picture properly.

3. Select a target echo which should be displayed straightly.

4. Press the [4] key to choose the [TIMING ADJ] on the [ECHO ADJ] menu.

[ECHO ADJ]

1 BACK

2 CABLE ATT ADJ

AUTO/MANUAL

3 HD ALIGN

000.0°

4 TIMING ADJ

5 MBS

6 DEFAULT ANT HEIGHT

5/7.5/10/15/20/ 25/30/35/40/45/ more 50 m

7 NEAR STC CURVE

2/2.5/3/3.5/4.2

8 MID STC CURVE

3/4/5/6

9 FAR STC CURVE

6/7/8

0 RING SUPPRESSION

5. Rotate the wheel to set a suitable value which causes the target to be displayed straightly. The setting range is 0 to 4095.

6. Press the [MENU] key to finish.

3-8

3.6 Suppressing Main Bang

If main bang appears at the screen center, suppress it as follows.

1. Transmit the radar on a long range and then wait ten minutes.

2. Adjust gain to show a slight amount of noise on the display.

3. Select the 0.25 nm range. Adjust sea clutter control to suppress sea clutter.

4. Press [5] key to choose the MBS on the [ECHO ADJ] menu.

[ECHO ADJ]

1 BACK

2 CABLE ATT ADJ

AUTO/MANUAL

3 HD ALIGN

000.0°

4 TIMING ADJ

5 MBS

6 DEFAULT ANT HEIGHT

5/7.5/10/15/20/ 25/30/35/40/45/ more 50 m

7 NEAR STC CURVE

2/2.5/3/3.5/4.2

8 MID STC CURVE

3/4/5/6

9 FAR STC CURVE

6/7/8

0 RING SUPPSSION

5. Rotate the wheel to set a suitable value so that the main bang disappears.

The setting range is 0 to 255.

6. Press the [MENU] key to finish.

3-9

3.7 Other Settings

ECHO menu setting Open the ECHO ADJ menu as described on pages 3-4 and 3-5.

[ECHO ADJ]

1 BACK

2 CABLE ATT ADJ

AUTO/MANUAL

3 HD ALIGN

000.0°

4 TIMING ADJ

5 MBS

6 DEFAULT ANT HEIGHT

5/7.5/10/15/20/ 25/30/35/40/45/ more 50 m

7 NEAR STC CURVE

2/2.5/3/3.5/4.2

8 MID STC CURVE

3/4/5/6

9 FAR STC CURVE

6/7/8

0 RING SUPPRESSION

To close the menu, press the [MENU] key.

CABLE ATT ADJ

Before adjusting, set the radar as follows:

IR: 2, ES: off, EAV: off, 24nm range, long pulse (Same as default setting of PICTURE1) To adjust the cable attenuation manually, choose MANUAL by pressing [2] and the [ENTER] key, and then rotate the wheel so that noise just appears on the screen when the gain is set to 80. Default setting is 30 for the antenna cable length of 15m. The setting range is 0 to 73.

To adjust automatically, choose AUTO and press the [ENTER] key. The message “CABLE ATT ADJ” appears in yellow at the bottom of the screen. It takes about five minutes to complete the adjustment, after which the radar goes into stand-by.

DEFAULT ANT HEIGHT

Select height (m) of the radar antenna unit from the sea surface among 5, 7.5, 10, 15, 20, 25, 30, 35, 40, 45 and “more 50 m”.

NEAR STC CURVE, MID STC CURVE AND FAR STC CURVE

Use the default setting. Change the setting if desired according to sea condition.

RING SUPPRESSION

This is mainly used to removes “ring” noise which appears in the waveguide-type radar.

Adjust so the rings disappear at the range of 0.125 nm. The setting range is 0 to 255.

3-10

Scanner setting

1. Open the INITIALIZE menu described on page 3-3.

2. Press [3] key to open the SCANNER menu.

[SCANNER]

1 BACK

2 BLIND SECTOR 1

START 000°

ANGLE 000°

3 BLIND SECTOR 2

START 000°

ANGLE 000°

4 ANT REVOLUTION

LO/HI/AUTO

5 ANT SW

OFF/ON/EXT

6 ANT STOPPED

STBY/TX

7 M SPEC

OFF/ON

8 BB TYPE

NORMAL/BB

9 [DUAL RADAR]*

Note 1: Set the blind sector as minimum as possible.

Note 2: Do not set the blind sector in the bow direction.

*non IMO-type only

To close the menu, press the [MENU] key.

BLIND SECTOR 1 and BLIND SECTOR 2

Set area (up to 2) where no radar pulses will be transmitted, and heading should be adjusted before setting any blind sector. For example, set the area where an interfering object at the rear of the scanner would produce a dead sector (area where no echoes appear) on the display. To enter an area, enter start bearing relative the heading and dead sector angle. To erase the area, enter 0 for both the START and ANGLE sections.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .