LL-11-D O2K Rev 1 Page 1 of 14
SURVEY FOR LOAD LINES
INTERNATIONAL CONVENTION ON LOAD LINES, 1966
(IMO STANDARD FORM)
RECORD OF CONDITIONS OF ASSIGNMENT
Report No.: Date:
Name of Ship
Port of Registry Nationality
Distinctive Number or Letter
Shipbuilders
Yard Number
Date of Construction / Conversion
Freeboard assigned as a ship of Type
Classification
Date and place of initial survey
YY187051-957687-004 20 January 2010
UNDOCUMENTED
CG918222 WTEK
VT HALTER MARINE
20 January, 2010 VT Halter Marine, Pascagoula, Ms.
15 June 2007
"B"
O2K Rev 1 LL-11-D Page 2 of 14
A plan of suitable size may be attached to this Report in preference to sketches on this page.
Disposition and dimensions of superstructures, trunks, deckhouses, machinery casings; extent of bulwarks, guard rails and wood sheathing on exposed decks, to be inserted in the diagrams and tables following; together with positions of hatchways, gangways, and other means for the protection of the crew; cargo ports, bow and stern doors, side scuttles, scuppers, ventilators, air pipes, companionways, and other items that would affect the seaworthiness of the ship.
Report No.: Date:
YY187051-957687-004 20 January 2010
SEE ATTACHMENTS 2A of 14 AND 2B of 14
O2K Rev 1 LL-11-D Page 3 of 14
DOORWAYS IN SUPERSTRUCTURES, EXPOSED MACHINERY CASINGS AND DECKHOUSE PROTECTING
OPENINGS IN FREEBOARD AND SUPERSTRUCTURE DECKS (Regs. 12, 17 & 18)
Location
Ref. No.
on Sketch or Plan Page 2 Number and Size of Openings
Height of Sills Type and Material
Number of Dogs
Closing Appliances
Companionway for bosun store in Position 1 leading below the freeboard deck.
In bridge forward bulkhead.
In bridge after bulkhead
In raised quarter deck bulkhead.
In poop bulkhead
In exposed machinery casings on freeboard deck
Date:Report No.:
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
20 January 2010YY187051-957687-004
O2K Rev 1 LL-11-D Page 4 of 14
Location
Ref. No.
on Sketch or Plan Page 2 Number and Size of Openings
Height of Sills Type and Material
Number of Dogs
Closing Appliances
In exposed machinery casings on superstructure deck
In machinery casings within superstructures or deckhouse on freeboard deck
In deckhouse in Position 1 enclosing openings leading below freeboard deck
In deckhouses in Position 2 enclosing openings leading within enclosed superstructures or below freeboard deck
In exposed pump room casings
DOORWAYS IN SUPERSTRUCTURES, EXPOSED MACHINERY CASINGS AND DECKHOUSE PROTECTING
OPENINGS IN FREEBOARD AND SUPERSTRUCTURE DECKS (continued)
Date:Report No.:
1, 73x30 in with 11.8 in. dia. fixed tempered glass 1, 63x30 in.
15 in 16 in.
QAWTD HINGED
STEEL HINGED
STEEL
1, 63x30 in with 11.8 in. dia. fixed tempered glass 2, 62x30 in. with 9.8 in. dia. fixed tempered glass
15.75 in.
16.34 in.
QAWTD, HINGED
STEEL A60 FIRE
RETARDING DOOR
(WEA. TIGHT)
In deckhouses, in position 1 enclosing openings leading within enclosed superstructures or below freeboard deck
In deckhouses, in position 1 enclosing openings leading within enclosed superstructures or below freeboard deck
N/A
N/A
N/A
N/A
N/A
N/A
1, 54x30 in. QAWTD, HINGED
STEEL
26 in. 6
N/A
O2K Rev 1 LL-11-D Page 5 of 14
DOORWAYS IN SUPERSTRUCTURES, EXPOSED MACHINERY CASINGS AND DECKHOUSE
PROTECTING OPENINGS IN FREEBOARD AND SUPERSTRUCTURE DECKS (continued)
Location
Ref. No.
on Sketch or Plan Page 2 Number and Size of Openings
Height of Sills Type and Material
Number of Dogs
Closing Appliances
Date:Report No.:
5 2, 63x30 in. 15 in HINGED STEEL 2
6 1, 63x30 in. with 11.8 in. dia. fixed tempered glass
15 in. HINGED STEEL 2
In deckhouses, in position 1 enclosing openings leading within enclosed superstructures or below freeboard deck
In deckhouses, in position 1 enclosing openings leading within enclosed superstructures or below freeboard deck
9 1, 72x30 in. with 11.8 in dia. fixed tempered glass
6 in. QAWTD HINGED
STEEL
2In superstructure deck in position 2 enclosing openings leading within enclosed superstructures or below freeboard deck.
2 2, 72.5x36 in. with 19.7x14 in. fixed tempered glass
6 in. QAWTD, HINGED
STEEL
2In bridge longitudinal bulkheads leading from bridge wings
O2K Rev 1 LL-11-D Page 6 of 14
HATCHWAYS AT POSITION 1 AND 2 CLOSED BY PORTABLE COVERS AND
SECURED WEATHERTIGHT BY TARPAULINS AND BATTENING DEVICES (Reg. 15)
PORTABLE BEAMS Number
Spacing b1 x tf
D x tw b2 x tf
Means of securing each beam
Bearing Surface
Material
Thickness
Direction fitted
Bearing Surface
PORTABLE COVERS
TARPAULINS
No. of layers
Material
Spacing of Cleats
Height of coamings above deck
Means of securing each section of covers:
Are wood covers fitted with galvanized end bands?
Position 1 --- Upon exposed freeboard and raised quarter decks, and upon exposed superstructure decks situated forward of a point located a quarter of the ship's length from the forward perpendicular.
Position 2 --- Upon exposed superstructure decks situated abaft a quarter of the ship's length from the forward perpendicular.
Some authorities require that galvanized steel bands protecting the ends of wood hatch boards be efficiently secured.
Indicate if fitted.
Note:
Position and Reference No.
on Sketch or Plan --- Page 2
Dimensions of clear opening at top of coaming
Date:Report No.:
O2K Rev 1 LL-11-D Page 7 of 14
HATCHWAYS AT POSITION 1 AND 2 CLOSED BY WEATHERTIGHT COVERS OF STEEL (OR OTHER
EQUIVALENT MATERIAL) FITTED WITH GASKETS AND CLAMPING DEVICES (Reg. 16)
MACHINERY SPACE OPENINGS AND MISCELLANEOUS OPENINGS IN FREEBOARD AND SUPERSTRUCTURE DECKS (Regs. 17 & 18)
Dimensions of clear opening at top of coaming
Type of cover or Patent Name Material
Height of coaming above deck
Dimensions of clear opening at top of coaming
Position and Reference No. on Sketch or Plan--2
Type of cover or Patent Name
Height of coaming above deck
Position and Reference No. on Sketch or Plan--2
Position and Reference No. on Sketch or Plan--2
Height of coaming
Dimensions
COVER
Material
How attached
Number and spacing of Dogs
Position and Reference No. on Sketch or Plan--2
Height of coaming
Dimensions
COVER
Material
How attached
Number and spacing of Dogs
Note:
A Freeboard Deck
B Freeboard Deck
C Freeboard Deck
D 01 Deck
E 01 Deck
F 01 Deck
FLUSH FLUSH 24 in, RAISED FLUSH FLUSH FLUSH
15x23 in 23.5x23.5 in. 23.5x23.5 in. 23.5x23.5 in. 23.5x23.5 in. 26.75 in. dia.
STEEL
BOLTED, WT
STEEL
QAWT, HINGED
STEEL
QAWT, HINGED
STEEL
BOLTED, WT
STEEL
BOLTED, WT
STEEL
QAWT, HINGED
20 BOLTS, EQUAL 4 DOGS, EQUAL 4 DOGS, EQUAL 32 BOLTS, EQUAL 32 BOLTS, EQUAL 4 DOGS, EQUAL
N/A N/A N/A N/A N/A N/A
O2K Rev 1 LL-11-D Page 8 of 14
MACHINERY SPACE OPENINGS AND MISCELLANEOUS OPENINGS IN FREEBOARD AND SUPERSTRUCTURE DECKS (Regs. 17 & 18) (continued)
Note:
Position and Reference No. on Sketch or Plan--2
Height of coaming
Dimensions
COVER
Material
How attached
Number and spacing of Dogs
Position and Reference No. on Sketch or Plan--2
Height of coaming
Dimensions
COVER
Material
How attached
Number and spacing of Dogs
Position and Reference No. on Sketch or Plan--2
Height of coaming
Dimensions
COVER
Material
How attached
Number and spacing of Dogs
N/A N/A N/A N/A N/A N/A
O2K Rev 1 LL-11-D Page 9 of 14
VENTILATORS ON FREEBOARD AND SUPERSTRUCTURE DECKS (POSITION 1 AND 2) (Reg. 19)
(1) In vessels less than 100 meters (328 ft.)
Closing Appliances: Are to have covers permanently attached. Indicate means of attachment, such as chained, hinged, etc., in Remarks column.
(2) Coamings of ventilators which exceed 900 m/m (35½ “) in height are to be specifically supported. Indicate means of support in Remarks column.
Closing Appliance Remarks CoamingNumber
FittedDeck on which fitted HeightDimensions
Date:Report No.:
Attached, hinged cover, 2 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 2 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 2 Dogs Louvered Wall Ventilator Attached, hinged cover, 2 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 2 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 2 Dogs Louvered Wall Ventilator Attached, hinged cover, 2 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 6 Dogs Louvered Wall Ventilator Attached, hinged cover, 6 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 2 Dogs Louvered Wall Ventilator Attached, hinged cover, 2 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 2 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 2 Dogs Louvered Wall Ventilator Attached, hinged cover, 2 dogs Gooseneck Vent Articulated Louvered Ventilator Attached, hinged cover, 6 Dogs Articulated Louvered Ventilator Articulated Louvered Ventilator Articulated Louvered Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Wall Ventilator Attached, hinged cover, 2 Dogs Louvered Wall Ventilator Attached, hinged cover, 4 Dogs Louvered Ventilator Attached, hinged cover, 1 Dog Louvered Ventilator
Deckhouse end Deckhouse end Deckhouse side Deckhouse end Deckhouse side Deckhouse end Stack Stack Stack Emerg. Gen cooling intake.
Deckhouse end Deckhouse
87" 84" 88" 92" 87.5" 87" 89" 85" 52" 88" 89" 84" 92" 93" 86" 91" 91" 91" 86" 86" 79" 85" 94" 94" 81" 88" 84" 94"
75.5 " 70" 94.5" 28" 69" 33" 30" 15" 84" 88" 91" 6" 32"
12"X12" 18"X17.5" 18"X17.5" 4"X4" 18"X17.5" 18"X17.5" 8"X8" 12"X12" 12"X32" 18"X17.5" 18"X17.5" 18"X17.5" 4"X4" 14.5"X9.5" 18"X17.5" 4"X4" 4"X4" 19.5"X9.5" 49.5"X18" 32"X27" 18"X17.5" 18"X17.5" 6"X6" 6"X6" 20"X20" 18"X17.5" 18"X17.5" 4"X4" 18"X17.5" 18"X17.5" 4"X4"
12" DIA
27'X84" 39"X39" 25"X39" 42"X35.5" 18"X17.5" 15"X15" 10"X10" 19"X32" 12"X17"
FREEBOARD DECK FR 48 S
FREEBOARD DECK FR 48 S
FREEBOARD DECK FR 47 S
FREEBOARD DECK FR 46.5 S
FREEBOARD DECK FR 43 S
FREEBOARD DECK FR 41 S
FREEBOARD DECK FR 39.5 S
FREEBOARD DECK FR 36.5 S
FREEBOARD DECK FR 32.5 S
FREEBOARD DECK FR15 S
FREEBOARD DECK FR 12 S
FREEBOARD DECH FR 11.5 S
FREEBOARD DECK FR 9.5 S
FREEBOARD DECK FR 9 S
FREEBOARD DECK FR 8 S
FREEBOARD DECK FR 7.5 S
FREEBOARD DECK FR 5 S
FREEBOARD DECK FR 5 P
FREEBOARD DECK FR 9 P
FREEBOARD DECK FR 12 P
FREEBOARD DECK FR 14 P
FREEBOARD DECK FR 18.5 P
FREEBOARD DECK FR 33 P
FREEBOARD DECK FR 38 P
FREEBOARD DECK FR 39 P
FREEBOARD DECK FR 40.5 P
FREEBOARD DECK FR 42 P
FREEBOARD DECK FR 44 P
FREEBOARD DECK FR 47 P
FREEBOARD DECK FR 48 P
FREEBOARD DECK FR 48 P
01 LEVEL FR 47.5 P
01 LEVEL FR 38 P/S
01 LEVEL FR 37 P/S
01 LEVEL FR 36 P/S
01 LEVEL FR 35 P
01 LEVEL FR 35 P
01 LEVEL FR 23 P
01 LEVEL FR 21.5 S
02 LEVEL FR 32 P
02 LEVEL FR 23 C
O2K Rev 1 LL-11-D Page 10 of 14
AIR PIPES OF FREEBOARD AND SUPERSTRUCTURE DECKS (Reg. 20)
Describe Closing ApplianceCoamingNumber FittedDeck on which fitted
HeightDimensions
Date:Report No.:
VERTICAL BALL FLOAT CHECK VALVE (WINTEB.NL) INBOARD STBD DECK HOUSE IN RECESS VERTICAL BALL FLOAT CHECK VALVE (WINTEB.NL) VERTICAL BALL FLOAT CHECK VALVE (WINTEB.NL) VERTICAL BALL FLOAT CHECK VALVE (WINTEB.NL) VERTICAL BALL FLOAT CHECK VALVE (WINTEB.NL) VERTICAL BALL FLOAT CHECK VALVE (WINTEB.NL) AGAINST FACE OF DECK HOUSE INVERTED BALL FLOAT CHECK VALVE (WINTEB.NL) AGAINST FACE OF DECK HOUSE VERTICAL BALL FLOAT CHECK VALVE (WINTEB.NL) AGAINST FACE OF DECK HOUSE VERTICAL BALL FLOAT CHECK VALVE (WINTEB.NL) AGAINST FACE OF DECK HOUSE VERTICAL BALL FLOAT CHECK VALVE (WINTEB.NL) VERTICAL BALL FLOAT CHECK VALVE (WINTEB.NL) VERTICAL BALL FLOAT CHECK VALVE (WINTEB.NL) VERTICAL BALL FLOAT CHECK VALVE (WINTEB.NL) VERTICAL BALL FLOAT CHECK VALVE (WINTEB.NL) VERTICAL BALL FLOAT CHECK VALVE (WINTEB.NL) INVERTED BALL FLOAT CHECK VALVE (WINTEB.NL) INVERTED BALL FLOAT CHECK VALVE (WINTEB.NL) INVERTED BALL FLOAT CHECK VALVE (WINTEB.NL) INVERTED BALL FLOAT CHECK VALVE (WINTEB.NL) INVERTED BALL FLOAT CHECK VALVE (WINTEB.NL) INVERTED BALL FLOAT CHECK VALVE (WINTEB.NL) INVERTED BALL FLOAT CHECK VALVE (WINTEB.NL) INVERTED BALL FLOAT CHECK VALVE (WINTEB.NL) FLAME SCREENS FITTED ON ALL FUEL OIL AND
LUBE OIL TANK AIR PIPES
41.5" 41.5" 45.5" 45.5" 41.5" 44.5" 36.25" 42" 42" 44' 43" 45.5" 41.5" 44.5" 42" 34" 36" 36" 36" 36" 36" 36" 35.5"
2.5" 2.5" 4" 4.5" 2" 4.5" 2.5" 2.5" 2.5" 4.5" 2.5" 4.5" 2.5" 4.5" 2.5" 2.5" 1.5" 2.5" 2.5" 2.5" 4" 4" 1.5"
2 1 1 1 1 2 2 2 2 1 2 2 1 1 1 1 1 1 1 1 1 1 1
FREEBOARD DECK FR 46 S
FREEBOARD DECK FR 46 S
FREEBOARD DECK FR 42 S
FREEBOARD DECK FR 28 S
FREEBOARD DECK FR 28 S
FREEBOARD DECK FR 4 S
FREEBOARD DECK FR 4 C
FREEBOARD DECK FR 4 C
FREEBOARD DECK FR 4 P
FREEBOARD DECK FR 4 P
FREEBOARD DECK FR 15 P
FREEBOARD DECK FR 24 P
FREEBOARD DECK FR 25 P
FREEBOARD DECK FR 42 P
FREEBOARD DECK FR 46 P 02
LEVEL FR 30 P 01 LEVEL FR
32 S 01 LEVEL FR 15 S 01
LEVEL FR 16 S 01 LEVEL FR 15
P 01 LEVEL FR 15.5 P 01
LEVEL FR 16 P 01 LEVEL FR 32
P
O2K Rev 1 LL-11-D Page 11 of 14
Position of Controls State whether Accessible or
Operable From Freeboard Deck
State if Scupper or Discharge
Pipe Vertical distance above top of keel Number, Type and Material of Discharge
Valves Number From
Discharge
Outlet in hull
Inboard end
Uppermost valveDiameter Thickness Material
CARGO PORT AND OTHER SIMILAR OPENINGS (Reg. 21)
SCUPPERS, INLETS AND DISCHARGES (Reg. 22)
S --- Scupper D --- Discharge I --- Inlet
MS --- Mild Steel CS --- Cast steel GM --- Gun metal Any other approved material to be designated non-return
SD --- Screw down ANR --- Automatic non-return SD ANR ---Screw down automatic
NOTE: Symbols may be used at the discretion of the Surveyor.
RemarksSecuring devicesDistance of lower edge from freeboard deckDimensions of openingPosition of port
D
I
S
3IN.
2 IN
5 IN
3 IN
2.5 IN
6 IN
6 IN
SCH 80
STEEL
CUNI
BALLAST
GALLEY DRAINS
SEWAGE OVERBOARD
MN SW OVBD
AUX SW OVBD
BILGE/BALLAST OVERBOARD
AUX SW OVBD
MN SW INLET
WATER MAKER INLET
SEACHEST VENT
BALLAST/FIRE PUMP INLET
SEA DRAFT SENSOR
FREEBOARD DECK DRAIN
13.86 FT
17.1 FT
17.6 FT
12.53 FT
12.86 FT
2.16 FT
0.5 FT
4.91 FT
2.16 FT
10 IN
19.12 FT
23.37 FT
9.03
23.37 FT
3 FT
17.1 FT
17.6 FT
4.91 FT
15.88 FT
19.12 FT
2, SD, CS
2, ANR, CS
1, SD, CS
1 ANR, CS
1,SD, CS
1 ANR, CS
2, SD,, BZ
2 ANR, BZ
2, SD, BZ
2 ANR, BZ
2, SD, CS
2 ANR, CS
1, SD, BZ
1, ANR, BZ
2, SD, BZ
4, SD, CS
1 ANR, CS
OPERABLE FROM
FREEBOARD DECK
ACCESSIBLE
O2K Rev 1 LL-11-D Page 12 of 14
No side scuttle shall be fitted in a position so that its sill is below a line drawn parallel to the freeboard deck at side and having its lowest point 2.5 percent of the breadth (B) above the load waterline, or 500 millimeters (19½ inches) whichever is greater distance. Indicate all side scuttles not complying with this requirement.
NOTE: All side scuttles, windows fitted with efficient hinged inside deadlights are to be arranged so that they can be effectively closed and secured watertight.
Location of side scuttle, windows and/or skylights (airports to spaces below freeboard deck to spaces within enclosed super-structures, or to deck houses protecting access to spaces below freeboard deck.) Include side scuttles and windows fitted in doors.
SIDE SCUTTLES, WINDOWS AND SKYLIGHTS (Reg. 23)
Standards used and
Type No.
Type of Glass and
Thickness
Clear glass size
Fixed or opening
Frame Material
Attachment (H or PA)Material Location
(I or E)
Number fitted
Deadlight / Stormcover
I - Interior H - Hinged E - Exterior PA - Permanently Attached (second tier only) (second tier only)
20 January 2010YY187051-957687-004
Below freeboard deck - NONE Above freeboard deck -
- Port lights Mn Deck Level
- Port lights in doors, Mn Deck Level
- Side scuttles 01 Level
- Port lights in doors, 01 Level
Aluminum Steel Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum Steel
I E I I I I I I E
5 5 2 6 10 1 2 4
15.75 in.
Dia 11.8 in.
Dia 43.3x29.5 in.
Top 25.7xbot 19.75x29.5 in.
19.7x29.5 in.
19.7x23.6 in.
19.7x23.6 in 38.58x29.5 in.
11.8 in. Dia.
Fixed Fixed Fixed Hinged Hinged Hinged Fixed Fixed Fixed
Bronze retaining ring, steel frame Steel frame Steel frame Steel frame Steel frame Steel frame Steel frame Steel frame Steel frame
H H H H H H H
Tempered, .5 in Tempered, .315 in Tempered, .5 in Tempered, .5 in.
Tempered, .5 in.
Tempered, .5 in.
Tempered, .5 in.
Tempered, .5 in.
Tempered, .315 in.
ISO 614 ISO
614 ISO 614
ISO 614 ISO 614
ISO 614 ISO 614
ISO 614 ISO 614
O2K Rev 1 LL-11-D Page 13 of 14
Length of Bulwark
Height of Bulwark Number and Size of Freeing Ports each side Total Area each side Required Area each side
Freeboard Deck After Well
Forward Well
Superstructure Deck
FREEING PORTS (Reg. 24)
PROTECTION OF THE CREW (Regs. 25 & 26)
State fore and aft position of each freeing port in relation to superstructure end bulkheads
Particulars of shutters, bars or rails fitted to freeing ports:
Height of lower edge of freeing port above deck:
State particulars of bulwarks or guardrails on freeboard and superstructure decks:
State details of lifelines, walkways, gangways or underdeck passageways where required to be fitted:
Where is crew berthed?
Indicate if unmanned.
Date:Report No.:
N/A
41 in. 1 - 45.5"x13.5", 2- 19.5"x17.25", 4-12"x3", 2-6''x3"
N/A
FR -2 to FR-1, FR 1 to FR 2 & FR2 TO FR4 P/S, FR 2 1/2 P/S and Centerline
One .5 in. bar, welded 8.5 in. from lower edge of freeing ports.
.25 in
FREEBOARD DECK - Fixed Bulwark FR -3 to FR 6, 42 inches in height. Fixed three tier tubular steel open rail, 41 inches in height, 8.25 inches between lowest tier and top of side shell plate, 14inches between top tier and middle tier, 13.5 inches between middle and bottom tiers. Removable three tier stainless steel chain with turnbuckles, top tier 39.5 inches from deck, 8.75 in. between lowest and the deck, 14 in between middle and top tiers. 01 LEVEL - Fixed Bulwark FR 4 to FR 7, 41 inches in height. Fixed three tier tubular steel open rail, 41 inches in height, 8.25 inches between lowest tier and top of side shell plate, 14inches between top tier and middle tier, 13.5 inches between middle and bottom tiers. Removable three tier stainless steel chain with turnbuckles, top tier 39.5 inches from deck,
8.75 in. between lowest and the deck, 14 in between middle and top tiers. 02 LEVEL - Fixed three tier tubular aluminum open rail, 41 inches in height, 8.25 inches between lowest tier and top of side shell plate, 14inches between top tier and middle tier, 13.5 inches between middle and bottom tiers. Removable three tier stainless steel chain with turnbuckles, top tier 39.5 inches from deck, 8.75 in. between lowest and the deck, 14 in between middle and top tiers.
Lifelines fitted: Fr. 1 to 9 Port - A 3/8" dia. taut wire rope fitted inboard of bulwark for access to bow. Fr. 38 to 49 Stbd. - A combination of hand rail and hand grabs fitted for access to Stbd. Steering Gear Room.
Deckhouse
O2K Rev 1 LL-11-D Page 14 of 14
OTHER SPECIAL FEATURES
SKETCH GUNWALE CONNECTION
For Rounded Gunwale Indicate Relationship to Deckline Marked on Vessel to Deckline as Defined in Regulation 4.
The conditions of assignment shown on this form are a record of the arrangements and fittings provided on the ship and are in accordance with the requirements of the relevant regulations of the International Convention of Loadlines, 1966.
Surveyor
Date
TIMBER DECK CARGO FITTINGS (Regs. 44) State particulars of upright, sockets, lashings, guardrails and lifelines:
20 January 2010