Vertiline8C_Install.pdf

PDF 218 KB Posted

Attached to
Drydock and Repairs to NOAA SHIP THOMAS JEFFERSON
Solicitation number
EA-133M-13-RP-0154
Issued by

About this file

Vertiline Install

View the file

Other files

File Type Posted
Amendment_0009.pdf PDF
Q A_3.docx DOCX document
Amendment_0008.pdf PDF
SF_30.pdf PDF
Thomas_Jefferson_Drydock_Repairs_MOA2-08(13)_dated_28_Feb_13_Revised_25_Sep_13.pdf PDF
Amendment_0006.pdf PDF
ADCP Installation Guide 95A-6019-00.pdf PDF
SmartOnline 30kVA Owners manual.pdf PDF
TJ-Camera Equipment Locations.pdf PDF
TJ-635-6634624_Insulation Layout and Details.pdf PDF
TJ-085-002C_Booklet_of_General_Plans.pdf PDF
164851ac_installation_manual_em710(s).pdf PDF
89087_main switchboard assembly.pdf PDF
C3463M-C_Spectra_IV_SE Camera System Installation Manual.pdf PDF
SVP70_71_Manual102b(s).pdf PDF
SeaBat 7125 SV2_OpMan_V5(s).pdf PDF
TJ-633-01_Cathodic Protection System.pdf PDF
TJ-301-6634669_Electrical One Line Diagram.pdf PDF
Battery Module.pdf PDF
Knudsen KEL571 12kHz - D241-03457-Rev1.02 1 .pdf PDF
Furuno CA50B-6B transducer drawing C2003010.pdf PDF
TJ-241-01_Reduction_Gear(s).pdf PDF
Furuno CA200B-8B transducer drawing C2003019.pdf PDF
offsets and alignmets_04-27-2008.pdf PDF
Amendment_0005.pdf PDF
TJ-512-002 HVAC ARR Details Upper Deck Above .pdf PDF
Knudsen KELA5701 3_5kHz - D241-03802-Rev1.02.pdf PDF
Airmar HMBB200_24_4_20_information_sheet.pdf PDF
TJ-529-02 Elinca Anti-Biofouling System(s).pdf PDF
SyQwerst 3_5kHz - tr109.pdf PDF
Signed_Amendment_0004.pdf PDF
Amendment_0003.pdf PDF
Amendment_0001_Signed.pdf PDF
1167_001.pdf PDF
301-6634669 Electrical One Line Diagram.pdf PDF
490-6634715_001C Transducer arrangment.pdf PDF
85110021M011-REV-A_Seabat_7125_SV2_Sea_chest.pdf PDF
528-6643786 Plumbing and Deck Drain Arrangement.pdf PDF
593-6634823 Sewage and Sanitary Sys Arrangement and Details.pdf PDF
528-6634785_Plumbing and Deck Drains.pdf PDF
644-6634942_Sanitary Equipment Schedule.pdf PDF
501-6634831_Piping Module No 3.pdf PDF
593-6634822 Sewage and Sanutary Sys Diagram.pdf PDF
TJ-528-006 Sewage Grey Water Piping Mods in Engine Room.pdf PDF
TJ-528-004 Rev D_Sewage System Modifications.pdf PDF
533-1_Potable Water Tank Disinfection.pdf PDF
TJFY14DD_2013-09-12.pdf PDF
573-2_Overhaul_Repair of Hydraulic Cylinders.pdf PDF
000-1F_General Requirements for Ship Repair Contract Work on NOAA Ships.pdf PDF
000-2C_Temporary Services at Contractor Facilities.pdf PDF
Show 40 more

Latest 50 of 114 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CCTV Rack Mount Power Supplies

Installation Guide Models Include:

Vertiline8C Vertiline8CD

- 24VAC or 28VAC @ 5 amp - 24VAC or 28VAC @ 5 amp

- Eight (8) fuse protected outputs - Eight (8) PTC protected outputs

Vertiline83C Vertiline83CD

- 24VAC or 28VAC @ 10 amp - 24VAC or 28VAC @ 10 amp

- Eight (8) fuse protected outputs - Eight (8) PTC protected outputs

Rev. 031808 More than just power.TM

- 2 - Vertiline8C

Overview:

Altronix Vertiline CCTV Rack Mount Power Supplies provide 8 power outputs in a space saving 1U EIA 19” rack mount chassis which may be rack, wall or shelf mounted. The units feature individually selectable 24VAC and/or 28VAC power outputs with surge suppression. Vertiline CCTV Rack Mount Power Supplies are also available in sixteen (16) and twenty-four (24) output models with various power ratings.

Specifications:

Eight (8) Output Rack Mount Configuration Reference Chart:

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to all local codes and in accordance with the National Electrical Code.

Installation Instructions:

1. Attach mounting brackets to Vertiline unit for rack or wall mount installation (Figs. 4-5, pg. 7). Affix rubber pads to

Vertiline for shelf installation (Fig. 6, pg. 7).

2. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least

3” from any video monitors). When installing the unit in a rack allow for one half of a U spacing above the unit for ventilation.

3. Plug the grounded AC line cord (included) into the IEC 320 connector of the Vertiline unit (Fig. 1f, pg. 4).

Insert the plug end of the line cord into a grounded AC receptacle.

4. Set illuminated master power disconnect circuit breaker to the (ON) position (Fig. 3, pg. 6).

5. Select 24VAC or 28VAC power output for cameras 1-8 with the corresponding voltage adjustment switches

(Fig. 1b, pg. 4).

6. Measure output voltage before connecting cameras. This helps avoid potential damage.

All terminals with common suffix (P) “1P, 2P ...” are the same polarity.

7. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 3, pg. 6).

8. Connect the power outputs of terminals marked [1P & 1N] to the power inputs of camera 1 (Fig. 2, pg. 5).

Repeat this step for each additional camera (Outputs 2-8). After wiring is completed insert terminal block into the corresponding connector and secure by tightening the screws.

• 115VAC 60 Hz input.

• Eight (8) individually selectable 24VAC or 28VAC power outputs with OFF position.

• Eight (8) power LED indicators.

• External blade fuses or PTC protected outputs.

• Surge suppression.

• Illuminated power disconnect circuit breaker with manual reset.

• IEC 320 - 3-wire grounded line cord (detachable).

• Removable terminal blocks with locking screw flange.

• Ease of installation saves time and eliminates costly labor.

• Compact 1U rack mount chassis.

• Fits standard EIA 19” rack.

• Units can be rack, wall or shelf mounted.

Altronix Model Number

Vertiline8C 24VAC or 28VAC 5 amp 8 Fused -- 3 amp 3 amp

10 amp 1.5 amp

UL Listed for Commercial CCTV Equipment (UL 2044).

CUL Listed - CSA Standard C22.2 No.1-04, Audio, Video and Similar Equipment.

Vertiline8CD 24VAC or 28VAC 5 amp 8 -- PTC 2.5 amp --

Vertiline83C 24VAC or 28VAC 10 amp 8 Fused -- 3 amp 3 amp

15 amp 3 amp Vertiline83CD 24VAC or

28VAC 10 amp 8 -- PTC 2.5 amp --

To ta l O ut pu t C ur re nt (P ow er

O ut pu t

Vol ta ge (V

AC)

N um be r o f O ut pu ts

O ut pu t P ro te ct io n

Cla ss

R at ed

P ow er L im ite d

O ut pu t P ro te ct io n

Cur re nt

(m ax

. p er o ut pu t)

5V

AC 6

0H z

In pu t C ur re nt

A ge nc y

List in gs

Fu se

R at in g

M ai n Fu se R at in g

Vertiline8C - 3 -

9. Upon completion of wiring, set illuminated master power disconnect circuit breaker to the ON (RESET) position (Fig. 3, pg. 6).

10. The power LEDs (Green) on the faceplate for Outputs 1-8 will illuminate when AC power is present (Fig. 1a, pg. 4). If any of these LEDs are off, a loss of AC power output may be due to a blown fuse or a tripped PTC caused by a short circuit or overload condition. If all of the LEDs are OFF there may be a complete loss of supply power to the Vertiline unit or the illuminated master power disconnect circuit breaker is in the OFF position or the main fuse 1-8 is blown (Fig. 1c, pg. 4).* To restore the power output for Vertiline8C or Vertiline83C:

1- Switch corresponding output voltage switch to the OFF position (Fig. 1b, pg. 4).

2- Eliminate the trouble condition.

3- Replace the corresponding automotive blade fuse.* 4- Switch output voltage switch to the 24VAC or 28VAC position as desired (Fig. 1b, pg. 4).

To restore the power output for Vertiline8CD or Vertiline83CD:

1- Switch corresponding output voltage switch to the OFF position (Fig. 1b, pg. 4).

2- Eliminate the trouble condition.

3- Allow 1 minute for PTC to cool off.

4- Switch output voltage switch to the 24VAC or 28VAC position as desired (Fig. 1b, pg. 4).

*Note: Replace fuses with same type and rating:

Output fuses are rated @ 3 amp for all models.

Main fuse ratings:

10 amp for Vertiline8C and Vertiline8CD.

15 amp for Vertiline83C and Vertiline83CD.

Automotive Blade Fuse

- 4 - Vertiline8C

A C

P O

W

ER

VA

C O

FF

VA

C

M ai n Fu se 1-

N P

N P

N P

N P

N P

N P

N P

N P

O

FF

R E

S E

T

A C

P O

W

ER

M ai n Fu se 1-

N P

N P

N P

N P

N P

N P

N P

N P

1b

O u tp u t vo lt ag e sw it ch es

S el ec ts

4V

A C o r

V

A C or O

F F f or e ac h ou tp ut

1c

M ai n F u se

P ro te ct s th e tr an sf or m er ag ai ns t ov er lo ad

1a

L E

D (s

1-

8:

Po w er

L E

D i nd ic at or s.

1f

I E

C

C on n ec to r:

5V A

C

0H z

(g ro un de d li ne co rd i nc lu de d)

F ig

. 1

1d

P ow er O u tp u ts

V A

C or

8V

A C

1e

O u tp u t F u se s:

A ut om ot iv e bl ad e fu se s.

Ve rt il in e8 C

,V er ti li n e8

C D

Ve rt il in e8

3C o r Ve rt il in e8

3C D fr on t)

Ve rt il in e8 C o r

Ve rt il in e8 3C re ar

Ve rt il in e8 C

D o r Ve rt il in e8

3C D re ar

Ve rt il in e8 C

D a nd V er ti li ne

C

D d o no t ha ve o ut pu t fu se s on t he r ea r of t he r ac k m ou nt ch as si s.

T he o ut pu t P

T C s ar e lo ca te d on t he i ns id e of t he r ac k m ou nt c ha ss is

Vertiline8C - 5 -

F ig

. 2

A C

P O

W

ER

M ai n Fu se 1-

N P

N P

N P

N P

N P

N P

N P

N P

VA

C O

FF

VA

C

O

FF

R E

S E

T

T yp ic a l

H o o k u p

- 6 - Vertiline8C

1.625"

8.5"

.75"

19.125"

17.625"

(ON)

AC POWER

1 2 3 4 5 6 7 8

28VAC

OFF

24VAC

Main Fuse 1-8

N P N P N P N P N P N P N P N P

OFF

RESET

5678 1234

1U EIA 19” Rack Mount Chassis Mechanical Drawing & Dimensions:

1.625”H x 19.125”W x 8.5”D

TOP & BOTTOM

REAR

FRONT

Fig. 3 Power switch with built-in circuit breaker:

OFF position - Switch not Illuminated. Outputs not powered.

RESET (ON) position - Switch illuminated. Outputs powered.

Circuit breaker tripped - Switch not Illuminated. Power LEDs on faceplate are not illuminated. Outputs not powered.

To reset circuit breaker set power switch to the ON (RESET) position (Fig. 3, pg. 6).

The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated “DANGEROUS VOLTAGE” within the products enclosure that may be of sufficient magnitude to constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel.

Vertiline8C - 7 -

Mounting Options:

Fig. 4

Wall Mount Installation 1- Install mounting brackets (A) on the left and right side of rack chassis using two (2) flat head screws (B) (included) (Fig. 5a).

2- Place unit at desired location and secure with mounting screws (not included) (Fig. 5b).

Caution: It is necessary to make sure mounting screws are securely fastened to a beam when installing.

Rack Mount Installation 1- Remove factory installed screws from both sides of rack chassis (Fig. 4a).

2- Install mounting brackets (A) on the left and right side of rack chassis using the two (2) flat head screws (B) (included) (Fig. 4b).

3- Place unit into desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 4c).

Fig. 6

Fig. 5

Shelf Installation 1- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 6).

2- Place unit in desired location.

B

A

C

Mounting Hardware (Included):

B A

Fig. 5bFig. 5a

C

A

B

Fig. 4bFig. 4a Fig. 4c

Top Top Top

Front Left

Front Left

Front Left

Left Side

Rubber Pad

Two (2) mounting brackets

Six (6) flat head screws for mounting brackets.

Four (4) rubber pads.

Remove

- 8 - Vertiline8C

MEMBER

Altronix is not responsible for any typographical errors.

Altronix Corp.

140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A.

IIVertiline8CSeries B03I

Notes:

File details come from the government source that posted it. Updated .