SeaBat 7125 SV2_OpMan_V5(s).pdf
PDF 5 MB Posted
- Solicitation number
- EA-133M-13-RP-0154
About this file
SeaBat
View the file
Other files
Show 40 more
Latest 50 of 114 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SeaBat 7125 SV2 High-Resolution Multibeam
Sonar System
OPERATOR’S MANUAL
Part Number 86000169
Version 5
June 2012
This page intentionally left blank.
SeaBat 7125 SV2 Operator’s Manual Page i June 1, 2012
Notice The information contained in this document is subject to change without notice. RESON makes no warranty of any kind with regard to this material, including (but not limited to) the implied warranties of merchant liability and fitness for a particular purpose. RESON shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Copyright Statement
Copyright RESON A/S 2010. All rights reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, as per the copyright laws of Denmark.
SeaBat 7125 SV2 Operator’s Manual written by:
RESON A/S
Fabriksvangen 35 3550 Slangerup
Telephone: +45 47 38 00 22 Facsimile: +45 47 38 00 66
Web: http://www.reson.com E-mail: sales@reson.com support@reson.com
Copyright Release
No part of this manual may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or machine readable language, in any form or by any means for disclosure to third parties without the express written consent of
RESON A/S.
Version June 2012 Version 5
RESON strives to maintain up-to-date information and may, as necessary, review and revise this manual. If the information contained in this manual is unclear, please contact your nearest RESON office for clarification.
Maintenance Release
Release FP2
This manual is consistent with the indicated software and firmware maintenance release.
Electronic File Version
This manual is available from RESON in the Adobe® Acrobat® Portable Document Format (PDF). The selected PDF process preserves the interactive index and cross-reference features of the original Microsoft Word document.
http://www.reson.com/ mailto:sales@reson.com mailto:support@reson.com
SeaBat 7125 SV2 Operator’s Manual Page ii June 1, 2012
This page intentionally left blank.
SeaBat 7125 SV2 Operator’s Manual Page iii June 1, 2012
TABLE OF CONTENTS
1 Introduction
1.1 System Overview
1.2 System Architecture
1.3 System Operation
1.4 System Features
1.5 Typical Applications
2 Safety Precautions
2.1 Operator Safety
2.2 Equipment Safety
2.2.1 Safe Handling
2.2.2 Cleaning and Maintenance
2.3 Corrosion Avoidance
2.4 Electrical Isolation
2.5 Exposure to Sunlight
2.6 Safe Disposal of Waste (WEEE Directive)
2.7 CE Marking
3 System Startup and Shutdown
3.1 Chapter Overview
3.2 System Startup Instructions
3.3 Starting the 7k Control Center and Sonar
3.4 System Shutdown Instructions
3.5 Installing a License
4 System Configuration
4.1 Chapter Overview
4.2 Configuration Menu Options
4.2.1 Data Display & Format
4.2.2 UDP Broadcasting
4.2.3 Hardware Configuration
4.2.4 Advanced Ping Settings
4.2.5 Triggering
4.2.6 Dual Head
4.2.7 Motion
SeaBat 7125 SV2 Operator’s Manual Page iv June 1, 2012
4.2.8 Load
4.2.9 Save Current
4.2.10 Auto Pilot Settings
4.3 Frequency Switch (System Menu)
4.4 Channel Normalization
4.5 I/O Module Configuration
4.5.1 Device Types
4.5.2 Adding a Device
4.5.3 I/O Module Setup Check
4.6 Remote Operation
4.7 Folder Management
4.7.1 Sharing a Folder on a Network
4.7.2 Verifying or Changing the Computer Name and/or Workgroup Name
5 System Operation
5.1 Chapter Overview
5.2 User Interface
5.3 Primary Display Tab
5.3.1 Sonar Image
5.3.2 A-Scan Display
5.3.3 Event Messages
5.3.4 1PPS Input Indicator
5.3.5 Normalization Indicator
5.3.6 Freeze the Sonar Image
5.3.7 Maximize the Sonar Image
5.3.8 Change Modes
5.3.9 Identify Beam Track, Depth, and Range (or Channel and Sample)
5.3.10 Automatic Update of Auto Pilot Settings
5.4 Motion Tab
5.5 Snippets and Side Scan Tabs
5.6 Built-In Test Environment (BITE)
5.6.1 BITE
5.6.2 BITE Tabs
5.7 Sonar Control Tabs
5.7.1 Main Sonar Settings
5.7.2 Detection Settings
SeaBat 7125 SV2 Operator’s Manual Page v June 1, 2012
5.7.3 Ocean Settings
5.7.4 Primary Display Settings
5.7.5 Data Recording
5.7.6 Screen Recording (Video Recording)
5.7.7 I/O Module Setup
5.7.8 Data Playback
5.8 7k Center Console Window
5.9 Help Menu
5.9.1 Licensed Features
5.9.2 Software Release Information
6 Active Sonar Usage
6.1 Chapter Overview
6.2 Enhancing the Sonar Image
6.2.1 Pulse Length and Image Resolution
6.2.2 Transmit Power OFF
6.2.3 Lower Ping Rate
6.2.4 Receiver Gain
6.2.5 Vari-Swath
6.2.6 Correct Range Setting
6.2.7 Minimum Beams, Intermediate, and Best Coverage Modes
6.2.8 Use of Gates
6.3 System Efficiency
6.3.1 Auto Pilot
6.3.2 Roll Stabilization
6.3.3 Head Tilt
6.4 Use of Displays
6.4.1 Wedge versus B-Scan Display
6.4.2 A-Scan, Phase and Magnitude Displays
6.5 Water Column Data Recording
6.5.1 External RAID
6.5.2 Local Recording
6.6 Compensation for Environmental Conditions
6.6.1 Loss of Sound by Absorption
6.6.2 Loss of Sound by Spreading
6.6.3 Sound Velocity
SeaBat 7125 SV2 Operator’s Manual Page vi June 1, 2012
6.7 Limitations
6.7.1 Cavitation
6.7.2 Machinery Noise
6.7.3 Interference from Other Sonar Systems
6.7.4 Speed
6.7.5 Air Bubbles
6.7.6 Environment
7 System Performance and Data Types
7.1 Beam Modes
7.1.1 Minimum Beams
7.1.2 Intermediate
7.1.3 Best Coverage
7.1.4 Flex Mode
7.2 Data Types
7.2.1 Bathymetry Data
7.2.2 Side-Scan Data
7.2.3 Snippets Data
7.3 Best Coverage and Intermediate Modes
7.4 Quality
7.4.1 Brightness Test
7.4.2 Colinearity Test
7.4.3 Quality Filter
7.5 Uncertainty Estimation
7.6 Ping Rate Table
Appendix A Troubleshooting
A.1 System Warnings and Alarm Messages
A.2 Responding to Errors and Alarms
A.3 Alarm Messages
A.3.1 General System Startup Alarms
A.3.2 PCI Card Related (ADMXRC) Alarms
A.3.3 Data Reading Alarms
A.3.4 System Resource Alarms
A.3.5 Input Signal (Timing and Triggers) Alarms
A.3.6 Calibration Alarms
A.4 Warning Messages
SeaBat 7125 SV2 Operator’s Manual Page vii June 1, 2012
A.4.1 Configuration Warnings
A.4.2 Startup Warnings
A.4.3 Data Processing Warnings
A.4.4 Data Recording Warnings
A.4.5 BITE Data Warnings
A.4.6 Input Signal Warnings
A.4.7 System Stability Warnings
A.4.8 Data Subscription Warnings
A.4.9 Network Components Warnings
A.4.10 External Trigger Warnings
A.5 Alarm Messages – Master List in Alphabetical Order
A.6 Warning Messages – Master List in Alphabetical Order
Appendix B SeaBat 7125 Data Sheet
B.1 Ultra High-Resolution Multibeam Echosounder
B.2 SeaBat 7125 System Performance
B.3 SeaBat 7125 Physical Specifications
Appendix C Installation Instructions
C.1 Components Checklist
C.2 Installation Checklist
C.3 Dry-End Installation
C.3.1 Transceiver Installation
C.3.2 Transceiver Mounting
C.3.3 Transceiver Cable Connections
C.3.4 Monitor Connections
C.3.5 Simple Monitor Setup
C.3.6 Advanced Monitor Setup (Cloning Monitors)
C.4 Auxiliary Sensors
C.4.1 Sound Velocity Input
C.4.2 Motion Sensor Input
C.4.3 Time Input
C.4.4 Standard Serial Ports
C.4.5 RJ-45 to D-SUB9 Adaptor
C.5 SeaBat 7125 SV2 Cables
C.6 Wet-End Installation
C.6.1 EM 7216 Receiver Unit
SeaBat 7125 SV2 Operator’s Manual Page viii June 1, 2012
C.6.2 TC 2181 Projector Unit
C.6.3 Wet-End Mounting
C.6.4 Sonar Head Assembly Orientation
C.6.5 Sonar Reference Point
C.6.6 Wet-End Cable Connections
C.7 System Check
Appendix D Reference Documentation
D.1 SeaBat 7125 SV2 Documentation
D.2 SeaBat 7125 SV2 Design Documents
Appendix E SeaBat 7125 SV2 System Options
E.1 Extended Warranty Contract
E.2 External RAID Drive
E.3 Mounting Bracket
E.4 PDS2000 Data Acquisition Software
E.5 SeaBat Cables
E.6 Service and Support Agreements
E.7 Sound Velocity Probe
E.8 System Integration and Training
Appendix F Available SeaBat 7125 Configurations
F.1 Configurations
F.1.1 7125 SV Configuration
F.1.2 7125 ROV Configuration
F.1.3 7125 AUV Configuration
F.2 Feature Packages
Appendix G Easy Reference Tool for FP Variations
G.1 FP1 Release
G.1.1 Starting the 7k Control Center and Sonar (FP1)
G.1.2 Main Sonar Settings (200 or 400kHz) (FP1)
G.1.3 Set Variable Swath (FP1)
G.1.4 Advanced (Set Filters) (FP1)
G.1.5 FP1 Feature Packages
Appendix H Warranty Information
H.1 One Year Limited Warranty
H.2 Exclusions
SeaBat 7125 SV2 Operator’s Manual Page ix June 1, 2012
H.3 Warranty Limitations
H.4 Servicing During Warranty Period
H.5 Equipment Return Procedure
H.6 Service
Appendix I Glossary of Terms
LIST OF FIGURES
Figure 1: SeaBat 7125 SV2 Sonar System
Figure 2: SeaBat 7125 SV2 System Configuration
Figure 3: Transceiver Filter Location
Figure 4: Example of Trigger Output: Delay = 0, Pulse Width = 1
Figure 5: Sample of I/O Module Setup Tab
Figure 6: 7k I/O Module Window
Figure 7: User Interface with Display and Control Areas
Figure 8: Primary Display Tab
Figure 9: A-Scan and Sonar Wedge Display
Figure 10: B-Scan Display
Figure 11: Motion Tab
Figure 12: Typical Side-Scan Display
Figure 13: BITE Tab
Figure 14: BITE Status Tab
Figure 15: BITE – Link Control Tab
Figure 16: BITE – Receiver Tab
Figure 17: BITE – Projector Tab
Figure 18: BITE – Projector Tab, Expanded
Figure 19: BITE – 7kCenter Tab
Figure 20: Sample of Main Sonar Settings Tab
Figure 21: Range Setting Diagrams
Figure 22: Sample of Detection Settings Tab
Figure 23: Sample of Ocean Menu Tab
Figure 24: Sample of Primary Display Settings Tab
Figure 25: Sample of Data Recording Tab
Figure 26 Sample of Screen Recording Tab
SeaBat 7125 SV2 Operator’s Manual Page x June 1, 2012
Figure 27: Sample of Data Playback Tab
Figure 28: 7k Center Console Window
Figure 29: Licensed Features Information (Example Only)
Figure 30: Software Release Information (Example Only)
Figure 31: Example of Reduced Swath Width
Figure 32: Horizontal Swath Steering
Figure 33: Mouse Controls for Swath and Flex Mode Sector Widths, and Steering
Figure 34: Range Setting – Too Long
Figure 35: Range Setting – Too Short
Figure 36: Range Setting – The Exception
Figure 37: Depth Gates, With No Roll
Figure 38: Depth Gates, With Roll
Figure 39: Depth Gates, With Roll and Motion Sensor Input
Figure 40: Depth Gate Tilt
Figure 41: Swath under Zero Roll Conditions
Figure 42: Laterally Displaced Swaths under Roll Conditions
Figure 43: Swath under Roll Stabilization
Figure 44: Head Tilt Functionality
Figure 45: Head Tilt for Harbor Inspection
Figure 46: Head Tilt for Pipe Inspection
Figure 47: Water Column Data Recording to an External RAID
Figure 48: Water Column Data Recording Locally
Figure 49: Acoustic Absorption Reference
Figure 50: Typical Sound Velocity Values
Figure 51: Graphic Illustration of Flex Mode
Figure 52: Graphic Illustration of Snippets Data
Figure 53: Beam Density
Figure 54: Beam Spacing vs. Beam Angle
Figure 55: Beam Spacing
Figure 56: Across-Track Sounding Location on a Flat Bottom
Figure 57: Brightness Test
Figure 58: Colinearity Flags
Figure 59: Transceiver Unit
Figure 60: Transceiver Table Mounting
Figure 61: Transceiver Cable Connections
SeaBat 7125 SV2 Operator’s Manual Page xi June 1, 2012
Figure 62: Transceiver Diagnostic LEDs
Figure 63: SVP, Motion, and Time Standard Connections
Figure 64: RJ-45 to D-SUB9 Adaptor
Figure 65: SeaBat 7125 SV2 System Cables
Figure 66: Bend Radius
Figure 67: EM 7216 Receiver Unit
Figure 68: TC 2181 Projector Unit
Figure 69: System Documentation Link (Example Only)
Figure 70: Receiver, EM 7216 Outline Dimension
Figure 71: Projector, TC 2181 Outline Dimension
Figure 72: Cable Assembly, Transceiver to Receiver
Figure 73: Cable Assembly, Transceiver to Dual-Frequency Transmitter
Figure 74: 7125 Mounting Bracket Installation (optional)
Figure 75: Cable Assembly, Transceiver to SVP 70 (optional)
Figure 76: Cable Assembly, Transceiver to SVP 71 (optional)
Figure 77: Sonar Reference Point Definition, sheet 1
Figure 78: Sonar Reference Point Definition, sheet 2
Figure 79: Sonar Reference Point Definition, sheet 3
Figure 80: RAID Hard Disk Array
Figure 81: Sample of Main Sonar Settings Tab (FP1)
LIST OF TABLES
Table 1: TVG Formula
Table 2: Incorrect Range Settings – Examples and Solutions
Table 3: Ping Rate Table
Table 4: SeaBat 7125 System Performance
Table 5: SeaBat 7125 SV2 Components
Table 6: Transceiver Technical Specifications
Table 7: DVI and Analog Monitor Connections
Table 8: Display Port Connections
Table 9: Transceiver Port “SVP/Com3”
Table 10: Transceiver Port “Motion/Com4”
Table 11: Transceiver Port “Time/Com10”
SeaBat 7125 SV2 Operator’s Manual Page xii June 1, 2012
Table 12: Transceiver Ports “Com5”, “Com6”, “Com7”, “Com8”, “Com9”
Table 13: RJ-45 to DB9 Adaptor
Table 14: EM 7216 Receiver Unit Technical Specifications
Table 15: TC 2181 Projector Unit Technical Specifications
Table 16: RAID Hard Disk Array Technical Specifications
Table 17: SVP Technical Specifications
Table 18: Available Configurations
Table 19: SeaBat 7125 Feature Packages
Table 20: SeaBat 7125 Feature Packages (FP1)
SeaBat 7125 SV2 Operator’s Manual Page xiii June 1, 2012
PREFACE
How to Use This Manual This manual is valid for SeaBat 7125 SV2 systems with maintenance release FP1-FP2 (see Table 19 for FP overview). This manual is designed to accommodate both the first time user, who needs detailed instructions, and the experienced technician, who only requires a reference tool. It provides detailed procedures for the correct installation, operation, and maintenance of your RESON system.
Read this manual thoroughly and follow the steps provided to maintain optimal safety standards and to obtain the best system performance.
Standards of Measurement
All physical measurements represented in this document are based on the metric system. All temperatures are represented in degrees Celsius.
Document Conventions
The following information will make it easier for the reader to interpret the text presented in this document.
Document Conventions
Convention Definition Hyperlink Indicates a hyperlinked cross-reference. Click the word to be taken to the specified reference point.
Numbered list Indicates stepwise instructions to be followed in a particular order.
Bulleted list Indicates items of a list without any particular order.
Notes, Cautions, and Warnings
Notes, Cautions, and Warnings are included in this text to provide valuable information and to help the operator prevent damage to the sonar or to personnel. The following formats will be used:
NOTE
This is a Note. Notes provide explanatory information that may be useful to the operator, but is not necessarily vital to the operation of your RESON system.
CAUTION
This is a Caution. Cautions provide important information regarding your RESON system. Disregarding information provided in a Caution box may result in accidental misuse or damage to your RESON system.
SeaBat 7125 SV2 Operator’s Manual Page xiv June 1, 2012
WARNING!
This is a Warning. Warnings provide important information regarding your RESON system. Disregarding information provided in a Warning box may prove harmful to personnel working with or near the system.
Chapter Arrangement
All RESON manuals are designed with the same basic structure. The following chapters are included in this document:
Introduction provides a short summary of the SeaBat 7125 SV2 sonar system, including an overview of the architecture and the main features.
Safety Precautions provides important safety information about the SeaBat 7125 SV2 sonar system.
System Startup and Shutdown provides detailed information about how to start and shut down the SeaBat 7125 SV2 sonar system.
System Configuration provides detailed information about how to configure the SeaBat 7125 SV2 sonar system.
System Operation provides detailed information about the user interface and operation of the SeaBat 7125 SV2 sonar system.
Active Sonar Usage provides detailed information about the practical usage of the SeaBat 7125 SV2 sonar system.
System Performance and Data Types provides information about the types of data produced by the SeaBat 7125 SV2 sonar system.
In addition to the above chapters, these appendixes have been included for reference:
Appendix A: Troubleshooting
Appendix B: SeaBat 7125 Data Sheet
Appendix C: Installation Instructions
Appendix D: Reference Documentation
Appendix E: SeaBat 7125 SV2 System Options
Appendix F: Available SeaBat 7125 Configurations
Appendix G: Easy Reference Tool for FP Variations
Appendix H: Warranty Information
Appendix I: Glossary of Terms
If you require additional information or need clarification of any part of this document, please contact RESON Customer Support for assistance at support@reson.com.
INTRODUCTION
SeaBat 7125 SV2 Operator’s Manual Page 1 June 1, 2012
1 INTRODUCTION
1.1 System Overview
The SeaBat 7125 SV2 (for Surface Vessel) is a high-resolution multibeam sonar system that measures relative water depths over a 140°1 (or 165°) wide swath perpendicular to the vessel's track.
The SeaBat 7125 SV2 is a dual-frequency system designed for convenient installation on small surface vessels. The dual-frequency system provides high-resolution functionality with the 400kHz frequency and long-range functionality with the 200kHz frequency.
Figure 1: SeaBat 7125 SV2 Sonar System
For available configurations, see Appendix F Available SeaBat 7125 Configurations.
For available system options, see Appendix E SeaBat 7125 SV2 System Options.
For available feature packages, see Appendix F.2 Feature Packages.
1 Systems with FP1, only 128°
SeaBat 7125 SV2 Operator’s Manual Page 2 June 1, 2012
1.2 System Architecture
The SeaBat 7125 SV2 multibeam sonar system consists of a combined sonar interface and processing unit, known as the transceiver, as well as a receiver unit and a projector unit, both with dual-frequency operation. 25 meter cables connect the receiver and projector units to the transceiver. User displays and system control originate within the transceiver.
For details on the various system components, see Appendix C Installation Instructions.
EM 7216
Receiver Unit
TC 2181
Projector Unit
Monitor
Keyboard, mouse
WET END
DRY END
Transceiver
Optional PDS2000 (incl. 2 additional monitors)
Figure 2: SeaBat 7125 SV2 System Configuration2
1.3 System Operation
The projector unit of the sonar head assembly transmits a pulse of acoustic energy, which travels through the water and is reflected by the seafloor or any objects in its path.
The reflected signal is received by the receiver unit of the sonar head assembly, digitized by internal electronics, and sent to the topside transceiver for beamforming and
2 It is possible to connect four monitors to the transceiver.
SeaBat 7125 SV2 Operator’s Manual Page 3 June 1, 2012 processing. The transceiver generates the video displayed on the monitor and formats a digital output to be used by a peripheral bathymetric data processing system (or the optional PDS2000 DAC preinstalled on the transceiver) while functioning as the control interface between the operator and the sonar system.
1.4 System Features
The main features of the SeaBat 7125 SV2 system are summarized below. Depending on the feature package purchased3, all features may not be available (see appendix F.2 Feature Packages).
Resolution: Dynamic, focused beamforming maintains ultra-high resolution, even at short ranges. A receiver sample rate of 34kHz provides unprecedented range resolution and complements the narrow beam, thus providing the user with ultimate data quality and resolution.
Fast update: The entire 140° (or 165°) swath is illuminated with a single transmission at an update rate of up to 50Hz (range selection dependent), maintaining 100% bottom coverage, even at high speed.
Depth rating: The SeaBat 7125 SV2 is depth-rated to 50 meters.
Data output: The SeaBat 7125 SV2 exports the standard hydrographic records of bathymetry, side-scan, and snippets as well as water column data and other data for more scientific applications.
Beamforming: The transceiver performs initial signal processing, a combination of time delay and phase rotation beamforming.
Bottom detection: The special bottom detection algorithm uses a combination of center-of-energy and phase-zero crossing algorithms to detect the bottom in each individual beam with the highest possible accuracy.
Uncertainty output: Uncertainty is computed for each sounding and presented graphically on various UI (user interface) displays.
Variable swath coverage: This feature gives the operator control of the swath coverage. It includes swath width settings ranging from 45º to 140º (or 165º) in increments of 5º as well as a choice of beam density mode.
Steerable swath: This feature allows swath to be steered electronically.
Head tilt: This feature makes it possible to operate with a physically rotated sonar head, which allows for very flexible and specialized applications of the SeaBat 7125 SV2.
XYZ offsets: This feature makes it possible to take into account offsets between the projector and receiver, when these two separate units are mounted remotely from each other. This way bathymetric accuracy is maintained.
3 Feature Packages include Standard and Efficiency.
Some features are not available with maintenance releases prior to FP2.
SeaBat 7125 SV2 Operator’s Manual Page 4 June 1, 2012
Auto pilot: This feature allows for automatic update of certain sonar settings.
When Autopilot mode is initiated, the SeaBat analyzes bottom detection data to determine the average bottom depth and maximum usable swath angle, then optimizes the sonar settings accordingly consistent with a user-configurable look-up table.
Operator selectable operating mode: The choice of five different beam modes allows the operator to select a beam mode appropriate to the application thereby optimizing sonar operation. Wide mode yields a swath of 165º, while the other four modes yield a swath of 140º. In addition, Flex mode provides settings for alternative beam distribution.
Beam distribution: The SeaBat 7125 SV2 offers the operator a choice between Minimum Beams (equiangular spacing), Intermediate, and Best Coverage (equidistant spacing) at both the 200kHz and 400kHz frequency. All options are dynamically focused.
On the fly frequency change: The SeaBat 7125 SV2 dual-frequency system may be operated at either frequency without the need to restart the 7k Center.
On the fly beam mode selection: Choice of beam mode (spacing and number of beams) can be done without restarting the 7k Center.
Real-time QC display: The SeaBat 7125 SV2 generates a real-time display with an intensity image on a high resolution 19-inch LCD monitor. Overlaid on this intensity image is the bottom detection display, giving the operator an excellent QC (quality control) tool.
Hardware sync pulse out: A TTL pulse (synchronous with the transmit pulse) is available from the transceiver.
1PPS pulse handling and time stamping: Data time stamping is referenced to an incoming 1PPS and associated time message.
External trigger: The system may be triggered using a standard 7k Center software remote command or by a TTL incoming trigger pulse.
Adaptive gating: Three different gate settings are available for application to the bottom detection process: No Gates, Absolute Gates, and Adaptive Gates.
Beam data recording: The SeaBat 7125 SV2 is capable of producing a stream of beam data that is operator configurable and may be written to either the transceiver local hard drive or an optional external RAID hard disk array.
Data logging software controls recording, playback, and data storage functions.
Built-In Test Environment (BITE): BITE is an integral part of the transceiver, monitoring the status of internal subsystems and the wet-end units.
SeaBat 7125 SV2 Operator’s Manual Page 5 June 1, 2012
1.5 Typical Applications
The SeaBat 7125 SV2 is RESON’s third generation of sonar systems and is based around the 7125 SV transceiver. The modular approach to product design allows great flexibility and provides support for a wide range of applications including:
As-built surveys
Breakwater mapping
Coastal mapping
Harbor mapping
Hydrographic surveys to IHO Special Order and to U.S. Army Corps of Engineers Special Order
Pipeline inspection surveys
Pipeline route surveys
Pre- and post-dredging and condition surveys
Revetment surveys
River surveys
Search and recovery
Site clearance surveys
Underwater inspection and object location
SAFETY PRECAUTIONS
SeaBat 7125 SV2 Operator’s Manual Page 6 June 1, 2012
2 SAFETY PRECAUTIONS
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
RESON assumes no liability if this product is operated in an unsafe manner.
2.1 Operator Safety
The SeaBat™ system should be handled with attention to operator safety as well as protection of the hardware components. General precautions include:
DO NOT connect or disconnect cables with the power on.
DO NOT attempt to open and service the projector or receiver units.
DO NOT attempt to open and service the transceiver without specific instructions from RESON.
DO NOT operate the system while divers are in the water and closer than two meters from the projector and receiver units. High-powered ultrasonic energy can be hazardous to human physiology.
For safety reasons the SeaBat™ must be connected to protective earth. The protective earth pin in the mains appliance inlet is the protective conductor terminal of SeaBat™.
This icon on any of the SeaBat components implies hazardous voltage on output connection.
2.2 Equipment Safety
Each SeaBat™ component is sufficiently robust for shipboard storage while in its own transit case or shipping box, which include handles and tie-down rings. Use appropriate discretion in lifting these components, as the cases may be awkward and heavy.
2.2.1 Safe Handling
To ensure safe handling of the equipment:
Inspect each transit case or shipping box for physical damage prior to opening, and each component for physical damage before installation.
Use original shipping boxes to provide adequate packaging and shock absorption when shipping or storing the equipment.
SeaBat 7125 SV2 Operator’s Manual Page 7 June 1, 2012
Do not drop the equipment.
Do not connect or disconnect cables at the rear of the transceiver or from the sonar head assembly while the transceiver is running. This can damage the internal workings.
Do not bend cables beyond the recommended limits.
Do not place the sonar head in an area where the face may be scratched or damaged. If an array must be placed on the ground, it should be placed on a flat surface and covered with a protective padded sheet.
Do not place liquids on or near the equipment.
Ensure that the equipment is properly secured before putting out to sea.
When the sonar head is in air and switched on, the transmit power should be switched off except when performing system checks, where power should be increased to a level which is audible for a short time only on a slow repetition rate (follow instructions in appendix C.7 System Check). A higher setting may damage the transmit array ceramics. The system should only be operated in air for very short periods of time.
Do not exceed operating and storage temperature limits.
CAUTION
Do not operate transmitters in air except during system checks for short durations.
2.2.2 Cleaning and Maintenance
2.2.2.1 Projector and Receiver
The acoustic window molded over the front of the projector and receiver arrays is made of high-density polyurethane. A long range of chemicals will destroy the polyurethane, which include, but are not limited to:
Acids
Automotive brake fluid
Base
Grease
Halogenated hydrocarbons (carbon tetrachloride, trichloroethylene)
Hydraulic fluids
Ketenes (MEK, acetone)
Nitro hydrocarbons (nitrobenzene, aniline)
Oil
Ozone
Petrol
Phosphate ester
SeaBat 7125 SV2 Operator’s Manual Page 8 June 1, 2012
The following recommendations are made to protect the arrays while in use and in storage.
For cleaning, use a mild, nonabrasive soap, fresh lukewarm water, and a soft brush.
Rinse the sonar with fresh water after every use.
Do not clean the array or sonar by using hot or cold pressure washers. The high-velocity water spray will cut through the polyurethane or damage the interface between the polyurethane and the sonar metal housing.
To scrape away marine growth from the arrays, use only a wooden tool.
Do not apply any antifouling paint on the acoustic window unless the type is recommended by RESON. The antifouling paint will affect the acoustic performance. RESON recommends:
o For high-frequency transducers (>100kHz) use International VC 17m.
o For low-frequency transducers (<100kHz) use SigmaGlide.
NOTE
As these products are subject to technical modifications, it is recommended that the most up to date PDS4 and MSDS5 are acquired prior to commencing the coating work.
2.2.2.2 Wet-End Connectors
Use the wet connector maintenance kit delivered with your system (see Table 5: SeaBat 7125 SV2 Components) to protect the wet-end connectors.
The following guidelines are recommended:
Lubricate mating surfaces with a silicone oil or equivalent (silicone oil based).
Connectors must be lubricated on a regular basis.
DO NOT grease mating surface.
Avoid nicks and cuts around contacts as these are the sealing surfaces.
Elastomers can be seriously degraded if exposed to direct sunlight or high ozone levels for extended periods of time.
Do not overtighten bulkhead nuts.
Grip main body of connector during mating or unmating. Do not pull on cable to disconnect.
Avoid sharp bends at cable entry to connector.
4 Product Data Sheet 5 Material Safety Data Sheet
SeaBat 7125 SV2 Operator’s Manual Page 9 June 1, 2012
2.2.2.3 Transceiver Dust Filter
The transceiver is equipped with filters to prevent dust and other particles to enter the unit. The dust filters need to be changed at least once a year:
Figure 3: Transceiver Filter Location
1. Unscrew the four corner screws.
2. Lift off the front panel.
3. Replace the three dust filters.
4. Reassemble the transceiver.
2.2.2.4 Replacement of Battery on PC Motherboard
Battery to be changed by authorized personnel only.
Noncompliance may affect warranty situation (see Appendix H Warranty Information).
Use only the correct type of onboard CMOS battery as specified by the manufacturer.
Do not install the onboard battery upside down to avoid possible explosion.
SeaBat 7125 SV2 Operator’s Manual Page 10 June 1, 2012
2.3 Corrosion Avoidance
It is important that your SeaBat™ system be properly protected from the corrosive effects of the water in which the sonar head is submerged.
Aluminum components of your SeaBat system are not suitable for permanent installations on surface vessels. Aluminum components require regular cleaning with fresh water and sacrificial anodes must be inspected/renewed on a regular basis.
All aluminum housings are provided with zinc alloy sacrificial anodes to protect against galvanic corrosion while immersed in sea water, or with magnesium anodes for use in fresh water.
Take the following precautions to ensure the best usage of your SeaBat system’s sacrificial anodes.
Maintain electrical isolation between the sonar head and the mounting structure.
Do not paint the anodes.
Inspect the anodes periodically for cleanliness and good physical condition.
Tighten or replace loose anodes immediately.
WARNING!
Sacrificial anodes, when new, have a thin coating to prevent them from oxidizing. The first time the anodes come in contact with water the coating will dissolve thereby making the anodes active. If the anodes are removed from the water, even for a short period of time, they will oxidize (in a matter of minutes) forming a layer that must be removed before the anodes and sonar head are placed in the water again.
2.4 Electrical Isolation
Electrical isolation for both titanium and aluminum components may be achieved by using nonconductive bushings, washers, and isolation plates to insulate them from the mounting brackets. Common nonconductive materials include Delrin, G-10/FR4 glass fiber sheets, and high-density polyethylene sheets.
If the sonar head is not isolated from the mounting structure, galvanic corrosion will result in either the housing (aluminum housings) or in the mounting structure itself (titanium housings).
Additionally, an undue amount of stress will be put on the affected sacrificial anodes, causing them to be used very quickly.
Contact RESON for additional information on schemes for electrical isolation.
SeaBat 7125 SV2 Operator’s Manual Page 11 June 1, 2012
2.5 Exposure to Sunlight
Do not allow the projector and receiver arrays to sit in direct sunlight when not in use, but cover the arrays with a bag. In addition to furthering corrosive effects, continued exposure to ultraviolet (UV) rays will damage the polyurethane array face.
2.6 Safe Disposal of Waste (WEEE Directive)
The use of the crossed-out dustbin logo indicates that this product is subject to directive 2002/96/EC, known as the Waste Electrical and Electronic Equipment Directive. The WEEE Directive specifies that used electric/electronic equipment may not be treated as household waste, but must be sorted separately for disposal. These rules concern all your RESON products (computer, monitor, transducer, processor, probe, etc.)
and also all accessories (keyboard, mouse, etc.). By ensuring this product is disposed of correctly, you will help protect the environment.
For more detailed information about the recycling of this product, please contact your local authority, your household waste disposal service provider, or RESON Customer Support (support@reson.com)
2.7 CE Marking
This product carries the CE mark which indicates that it conforms to the essential health, safety, and environmental requirements of the relevant European Directives.
Directives o Electromagnetic compatibility (2004/108/EC) o Low Voltage Directive (2006/95/EC)
Standards o EN 61326-1: 2006 o EN 61000-3-2: 2006 o EN 61000-3-3: 1995 + A1: 2001 + A2: 2005 o EN 60945: 2002 part 9 and 10 o EN 61010-1: 2001
SYSTEM STARTUP AND SHUTDOWN
SeaBat 7125 SV2 Operator’s Manual Page 12 June 1, 2012
3 SYSTEM STARTUP AND SHUTDOWN
3.1 Chapter Overview
This chapter includes detailed instructions on the following subjects (click the emphasized hyperlink to be taken to the section):
System Startup Instructions: Consists of startup details.
Starting the 7k Control Center and Sonar: Consists of a description of the options available for setting up the sonar system for operation.
System Shutdown Instructions: Consists of details on stopping the system.
Installing a License: Consists of details on installing a license file.
For information on configuration of the system (including I/O module configuration, remote operation, and folder management), see section 4 System Configuration.
For information on the user interface and operation of the system, see section 5 System Operation.
For information on the practical use of the sonar, see section 6 Active Sonar Usage.
3.2 System Startup Instructions
After the SeaBat hardware has been installed (see Appendix C Installation Instructions), the system may be started. To do this, press the power buttons on both the transceiver and the color monitor.
The transceiver power button will be red, when power is connected to the unit; it will turn blue, when the system is turned on.
The transceiver will power up and boot directly into Windows. No user name or password is required for standard systems.
In the unlikely event that the system is hanging, press the power button on the transceiver for 10 seconds to shut down the system.
SeaBat 7125 SV2 Operator’s Manual Page 13 June 1, 2012
3.3 Starting the 7k Control Center and Sonar6
Once the system has been powered up, the 7k Control Center dialog appears.
1. Select the operating mode:
The 7k Control Center can operate the 7k Center and SeaBat display in real sonar operating mode or in simulator mode:
o Simulator mode: Select the Simulate check box. This mode displays a flat seabed and can be useful during installation and setup stages. Note that the sonar head need not be connected to operate in this mode.
o Real sonar mode: If the Simulate check box is unchecked, the system operates in real sonar mode.
2. Select the sonar head configuration:
If the sonar head has dual-head capability, the drop-down menu options are Single Head and Dual Head. Otherwise, Single Head is the only option. For details on the Dual Head configuration, see section 4.2.6 Dual Head.
3. Select the sonar settings:
The Sonar settings drop-down menu includes all of the possible sonar head configurations. This selection completes the configuration of the system to be started.
6 For systems with MR FP1, see appendix G.1.1 Starting the 7k Control Center and Sonar (FP1).
SeaBat 7125 SV2 Operator’s Manual Page 14 June 1, 2012
4. Click the Start button to the start the sonar.
The 7k Center starts first and is followed a few seconds later by the SeaBat display and user interface.
A console window similar to the one shown below appears upon startup, but is automatically hidden by the UI (see also section 5.8 7k Center Console Window).
SeaBat 7125 SV2 Operator’s Manual Page 15 June 1, 2012
3.4 System Shutdown Instructions
Improper shutdown of the transceiver can result in software problems.
After the system starts, the 7k Control Center Start button is replaced by a Stop button.
1. Click the Stop button to shut down both the 7k Center and the SeaBat display.
This does not terminate the 7k Control Center. The 7k Control Center remains active, ready to start the 7k Center and SeaBat display again with the same or different selection of sonar settings (see section 3.3 above).
If an error occurs, while the 7k Control Center is attempting to shut down the SeaBat display, the following dialog will appear:
If there is any unprocessed data when the error occurs, it is possible that portion will be lost. It is also possible that the current sonar settings (Depth, Range, etc.) are not saved the next time the sonar is started.
2. Click the cross in the upper right corner of the 7k Control Center to terminate the Control Center.
3. To shut down the transceiver press the power button (or follow normal Windows procedure).
CAUTION
Pressing the power button for a long time will turn the power supply off, which may cause Windows to start in safe mode at the next power up.
SeaBat 7125 SV2 Operator’s Manual Page 16 June 1, 2012
3.5 Installing a License
Your SeaBat 7125 SV2 comes with a license file installed that match the feature package you purchased (see Table 19: SeaBat 7125 Feature Packages). If upgrading to another feature package, the corresponding new license file must be installed.
1. Right-click the title bar of the 7k Control Center or the taskbar, and select Install License File.
2. Save the license file in a folder of your choice.
The default file location is the My Documents folder.
3. Click Open to load the license file.
SYSTEM CONFIGURATION
SeaBat 7125 SV2 Operator’s Manual Page 17 June 1, 2012
4 SYSTEM CONFIGURATION
4.1 Chapter Overview
This chapter includes detailed instructions on the following subjects (click the emphasized hyperlink to be taken to the section):
Configuration Menu Options: Consists of detailed instructions on setting up the parameters that determine the way the sonar system behaves.
Frequency Switch (System Menu): Consists of detailed instructions on how to use this feature.
Channel Normalization: Consists of detailed instructions on how to use this feature.
I/O Module Configuration: Consists of detailed instructions on setting up peripheral sensors (such as SVP and clock) and a presentation of the 7k I/O Module monitor window.
Remote Operation: Consists of instructions on how to control the sonar from a remote PC.
Folder Management: Consists of instructions on file sharing and renaming of computer or workgroup.
For information on starting, stopping, and setting up the SeaBat sonar system, see section 3 System Startup and Shutdown.
For information on the user interface and operation of the system, see section 5 System Operation.
For information on the practical use of the sonar, see section 6 Active Sonar Usage.
For information on installation and details on the various system components, see Appendix C Installation Instructions.
SeaBat 7125 SV2 Operator’s Manual Page 18 June 1, 2012
4.2 Configuration Menu Options
The various configuration options available for the SeaBat 7125 SV2 sonar system are shown in the following illustration and are described in detail in the subsections below.
4.2.1 Data Display & Format
The Data Display & Format dialog controls the type of 7k records that are generated and displayed. These selections also determine what data is displayed.
SeaBat 7125 SV2 Operator’s Manual Page 19 June 1, 2012
Water Column Data: Use the radio buttons to select either amplitude only or full beam data for display in the A-scan window to the left of the sonar wedge and for output over the Ethernet broadcast or storage to a Windows file.
o Signal Analysis Mode: Magnitude and phase data are both transmitted to the user interface. This allows for phase data to be analyzed in the A-scan displays. As this option increases the CPU usage for the SeaBat, RESON recommends that this option only be used when inspecting phase data.
o Operator Mode: The SeaBat extracts only the magnitude from the ping data. This data is then compressed to a maximum of 1024 samples. If less than 1024 samples are received in the ping, no compression occurs. This feature improves the performance of the system, but eliminates the ability to inspect the phase data.
General QC Displays: Select additional displays:
o Sidescan: Select the check box to display the Side Scan tab.
Snippets Control: Select the check box to display the Snippets tab.
o Sample Window Maximum: Not available.
o Maximum Sample Window (based on range): Not configurable.
4.2.2 UDP Broadcasting
The UDP Broadcasting dialog allows the operator to broadcast selected records to a remote IP address and UDP port.
From this dialog, you can:
Add, edit, or delete broadcast addresses.
Start or stop the broadcast process.
Save or load an existing broadcast configuration.
SeaBat 7125 SV2 Operator’s Manual Page 20 June 1, 2012
4.2.2.1 Add a New Broadcast
The Add button allows the creation of a new broadcast. To create a new broadcast:
1. Click the Add button to open the Connection dialog.
2. In the Connection dialog:
a. Enter a name for the broadcast in the Name field.
b. Enter the IP address of the target computer in the Remote IP field.
c. Enter the port number for the target computer (a valid port number is required).
d. Click Next to open the Add Records dialog.
SeaBat 7125 SV2 Operator’s Manual Page 21 June 1, 2012
3. In the Add Records dialog:
a. Select the records you want included in the broadcast by clicking on the record in the Available Records frame. Hold down the Ctrl key when selecting records, if you wish to add more than one record at a time.
b. Click the Add button to add the selected record(s) to the broadcast.
Successfully added records will appear in the Included Records frame.
c. Once you have selected the records required for your broadcast, click Next to open the Review Connection dialog.
NOTE
Refer to the Data Format Definition document for information regarding the records you require (see Appendix D Reference Documentation).
See also the example in Figure 47: Water Column Data Recording to an External RAID.
SeaBat 7125 SV2 Operator’s Manual Page 22 June 1, 2012
4. In the Review Connection dialog, review the information entered to make sure it is correct.
a. If you want to make changes, click Back to move back through the previous steps.
b. If you are satisfied that this is the connection you wish to create, click Finish to complete the process.
c. If you decide not to create a broadcast at this time, click Cancel to terminate the process without creating the new broadcast.
4.2.2.2 Edit an Existing Broadcast
To edit an existing broadcast, select the broadcast you wish to edit in the UDP Broadcasting dialog and click the Edit button, and then follow the same instructions as in section 4.2.2.1 Add a New Broadcast.
SeaBat 7125 SV2 Operator’s Manual Page 23 June 1, 2012
4.2.2.3 Delete a Broadcast
To delete an existing broadcast, select the broadcast you wish to delete in the UDP Broadcasting dialog and click the Delete button. A pop-up window will appear, asking you to confirm that you wish to delete the selected record. Click Yes to continue.
4.2.2.4 Start or Stop the Broadcast Process
To start a broadcast or stop an active broadcast, select the broadcast configuration from the UDP Broadcasting dialog list. The command button will indicate either Start for idle broadcast configurations or Stop for active configurations. Click the command (Start/Stop) button. The status indicates Active if the system is broadcasting messages to that address, or Idle if the system is not broadcasting messages to that address.
Active broadcast configurations are saved by the 7k Center software when it is stopped.
On startup, these broadcasts are resumed. Active broadcasts may also be viewed in the Remote Connections list on the 7kCenter BITE tab (see section 5.6.2.5 7kCenter Tab).
SeaBat 7125 SV2 Operator’s Manual Page 24 June 1, 2012
4.2.2.5 Save or Load an Existing Broadcast Configuration
The most recent broadcast configuration is automatically saved and loaded whenever you start the SeaBat. In some cases, however, the operator may want to save a particular configuration for later use or load a different (previously saved) configuration instead of setting it up manually.
To Save a Configuration:
1. Make sure the configuration is set up correctly.
2. Click the Save As button.
3. Enter a file name and choose the location to which you want this file saved.
The file extension is automatically set to (*.bcg).
4. Click Save.
To Load an Existing Configuration:
1. Click the Load button.
2. A warning box indicates that
a. The new configuration file will completely overwrite the current configuration, if the system is not broadcasting (is idle). Click OK if you want to continue.
b. The new configuration file will terminate active broadcasts. Click Yes if you want to continue. Click No if you want to stop and save a broadcast in progress.
3. Browse to the correct location and select the .bcg file you want to load.
4. Click Open.
SeaBat 7125 SV2 Operator’s Manual Page 25 June 1, 2012
4.2.3 Hardware Configuration
The Hardware Configuration dialog controls the one-time transmit array and projector settings. These settings should be set to reflect the initial installation of your system and should not require modification unless the physical installation changes. For details on sonar head installation, see appendix C.6.4 Sonar Head Assembly Orientation.
4.2.3.1 Configuration
Standard SV2 Mounting Bracket:
PN 85160026 (see also appendix E.3 Mounting Bracket):
Preset Configurations:
o Normal: When the receiver is mounted with the connector to the port side, the Configuration selection should be SV2 Bracket (see appendix C.6.4 Sonar Head Assembly Orientation).
SeaBat 7125 SV2 Operator’s Manual Page 26 June 1, 2012 o Reversed: When the receiver is mounted with the connector to the starboard side, the Configuration selection should be Reversed SV2 Bracket (see appendix C.6.4 Sonar Head Assembly Orientation). Note that this normalizes the image only and does not affect data output.
Customer Configuration:
o For nonstandard installations, the XYZ offset of the projector reference point from the receiver reference point must be defined. For details on reference points, see appendix C.6.5 Sonar Reference Point, and Figure 79: Sonar Reference Point Definition, sheet 3.
Incorrect offset settings could severely affect data quality.
4.2.3.2 Head Tilt7
The Head tilt feature allows the user to normalize the display, gates, and bottom detect processing to reflect the physical orientation of the sonar head. Users often tilt head to increase coverage to one side, particularly when surveying harbor walls or other vertical structures.
The angular value is entered in degrees (+ port up/- port down) and must be between - 45° and 45° in increments of 0.5°.
EA beams (Minimum Beams mode) are recommended when using head tilt, as ED beams (Best Coverage mode) are still formed assuming a horizontal seafloor.
For examples on how to use this feature, see section 6.3.3 Head Tilt.
7 Available with the Efficiency feature package (see Table 19).
Not available with maintenance releases prior to FP2.
SeaBat 7125 SV2 Operator’s Manual Page 27 June 1, 2012
4.2.4 Advanced Ping Settings
The Advanced Ping Settings dialog is not configurable. Default settings are Continuous Wave (CW) and Single Ping.
4.2.5 Triggering
The Trigger/PPS Configuration dialog allows the operator to control the pulse length and delay characteristics.
SeaBat 7125 SV2 Operator’s Manual Page 28 June 1, 2012
4.2.5.1 Trigger Input
Active: The Active check box is not selected (inactive) by default. When selected, the ping will occur upon receipt of the input trigger pulse. If the trigger pulse rate exceeds the sonar’s actual maximum ping rate for that range setting, some trigger input pulses may be dropped. Deselecting the check box will return the sonar to ping at the rate dictated by the settings on the Main Sonar Settings tab.
4.2.5.2 Trigger Output
A TTL trigger out pulse, approximately synchronous with the transmit pulse, is available via a BNC connector marked Trig Out on the rear panel of the transceiver (see appendix C.3.3 Transceiver Cable Connections). Figure 4 shows a pulse example.
Figure 4: Example of Trigger Output: Delay = 0, Pulse Width = 1
Active: The Active check box is selected by default. When selected, a pulse will be generated in conjunction with the sonar ping.
Delay: The default setting is 0.00ms. This setting allows the operator to specify how many milliseconds after the sonar ping the output pulse will be sent.
Pulse Length: The default setting is 1.00ms. This setting allows the operator to change the pulse length of the transmitted output signal. For the SeaBat 7125 SV, the pulse length plus the delay must be slightly less than 20ms.
Apply: Click the Apply button to finalize changes.
4.2.5.3 1PPS Polarity
Rising edge: By default, the SeaBat system accepts positively polarized (rising edge) 1PPS pulses to perform accurate time stamping.
SeaBat 7125 SV2 Operator’s Manual Page 29 June 1, 2012
Falling edge: If a negatively polarized (falling edge) 1PPS is used, the Falling edge button in the Trigger/PPS Configuration dialog must be selected to ensure accurate timing.
The 1PPS selection will appear on the sonar image control portion of the Primary Display tab (see also section 5.3.4 1PPS Input Indicator).
4.2.6 Dual Head8
To increase coverage, two complete sonar systems can…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .