BRIDGE INSPECTION REPORT
BRIDGE #2
FOOTHILLS PARKWAY OVER RAVINE
GREAT SMOKY MOUNTAINS NATIONAL PARK
LW
STRUCTURE NO. 5460-214P
INSPECTION TYPE: ROUTINE
INSPECTION DATE: 5/13/14
Report prepared by: NS
Federal Highway Administration Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 http://www.efl.fhwa.dot.gov/FLHBO/BIP http://www.efl.fhwa.dot.gov/FLHBO/BIP
STRUCTURE SUMMARY STRUCTURE NO. 5460-214P
BRIDGE #2 INSPECTION DATE: 5/13/14
BRIDGE IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL:
MAIN SPAN TYPE:
# OF BEAMS, MAIN SPAN: ..
DECK TYPE:
WEARING SURFACE:
ABUT. FOUNDATIONS:
PIER FOUNDATION(S):
ABUTMENT / PIER MAT'L: ...
PROJ./PLAN REF. NO:
NPS ROAD CLASS:
STRUCTURE HISTORY:
P/S CONCRETE CONTINUOUS
SEGMENTAL BOX GIRDER
CONCRETE PRECAST PANELS
MODIFIED CONCRETE
SPREAD FOOTING ON PILES
SPREAD FOOTING ON PILES
CONCRETE
PRA-FOOT 8E17 / 133/100030
6 - RESTRICTED
NO. OF MAIN SPANS:
NO. OF APPR. SPANS:
STRUCT. TOTAL LENGTH: ..
MAX. SPAN LENGTH:
DECK WIDTH:
CURB TO CURB WIDTH:
YEAR BUILT:
YEAR RECONSTRUCTED: ..
SKEW ANGLE:
FRACTURE CRITICAL:
790.0 FT (240.8 M)
180.0 FT (54.9 M)
36.8 FT (11.2 M)
34.0 FT (10.4 M)
N/A
0 °
NO
LOCATION
GREAT SMOKY MOUNTAINS NATIONAL PARK MILE POINT: ..................... 28.00 (KM PT 45.06)
STATE: ................................. TENNESSEE LOCATION: 3.0 miles west of Route 321
FACILITY CARRIED: ............ FOOTHILLS PARKWAY
FEATURE INTERSECTED: .. RAVINE
STRUCTURE EVALUATION SUMMARY
This post-tensioned segmental box girder bridge is in good condition overall. However there are some issues that require attention. These problems include cracking and delamination of the wearing surface along both curbs and along the center line; erosion exposing the south side of the west abutment footing, and water leakage through some railing posts, as evidenced by water stains on the deck overhangs. In addition, several segment joints of the box are exhibiting leakage and should be sealed with epoxy.
Corrective measures should be taken as outlined in this report to prevent the possible development of more serious or costly problems in the future.
INSPECTION TEAM: C. CASTRO, H. SALAD
CONDITION ASSESSMENT:
CARLOS CASTRO, P.E., FIELD TEAM LEADER 571-434-1546
REPORT REVIEW :
MARCUS MILLER, P.E., SENIOR INSPECTION ENGINEER 703-404-6252
REPORT APPROVAL: DATE: 9/30/14
JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5460-214P
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
D226 PRIORITY OF IMPROVEMENT
ITEM
NO.
MAINTENANCE RECOMMENDATIONS
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT COST
UNIT
ESTIMATE
COST
PRELIM.
59.1 SEAL (EPOXY INJECT) ALONG JOINT BETWEEN SEGMENTS OF BOX GIRDER AS
NECESSARY.
1 LS $ $
58.6 REPAIR ONGOING LEAKAGE THRU RAIL POST ANCHORAGE AS NECESSARY. 1 LS $ $
60.5,9 PROVIDE EROSION TREATMENT ON SLOPE AT SOUTH END OF WEST ABUTMENT. 1 LS $ $
58.2 PERIODICALLY REMOVE DEBRIS AND CLEAN EXPANSION JOINTS. 1 LS $ $
PRELIM. MAINTENANCE TOTAL : $
ITEM
NO.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST ESTIMATES
PRELIM. COST
REHAB. RECONSTR.
58.3 REPAIR DELAMINATION OF WEARING SURFACE THROUGHOUT. 1 LS $ $ $
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL : $ $
COST ESTIMATE SUMMARY
PRELIM. MAINTENANCE TOTAL:
PRELIM. REHABILITATION TOTAL:
PRELIM. RECONSTRUCTION TOTAL: ..
TOTAL ITEMIZED COSTS:
PRELIMINARY ESTIMATE TOTAL* :
(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)
REMARKS: No cost estimates provided because the bridge is still under warranty.
FIELD INSPECTION REPORT STRUCTURE NO. 5460-214P
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
“IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
NOT APPLICABLE
EXCELLENT CONDITION
VERY GOOD CONDITION - no problems noted.
GOOD CONDITION - some minor problems.
SATISFACTORY CONDITION - structural elements show some minor deterioration.
FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
N
58. DECK
ITEM REFERENCE AND REMARKS
OTHER
ALIGNMENT
DEFLECTION AND/OR VIBRATION
FASCIA(E)
DIAPHRAGMS AND BRACING
TRUSSES
FLOOR BEAMS AND STRINGERS
ARCH(ES) OR SLAB(S)
GIRDERS OR BEAMS
BEARING DEVICES
59. SUPERSTRUCTURE
OTHER
DEFLECTION AND/OR VIBRATION
UTILITIES
DRAINS AND DRAINAGE
PARAPETS AND/OR RAILINGS
CURBS, SIDEWALKS, AND MEDIAN
RIDEABILITY
WEARING SURFACE
EXPANSION JOINTS
DECK SLAB
ABUTMENTS
60. SUBSTRUCTURE
1.
10.
2.
3.
4.
5.
6.
7.
8.
9.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
PAINT
11.
G G N N N G N N G
N F
F G G G G N
N
G
G
G
58.1 MINOR CRACKING OF DECK OVERLAY AT RANDOM LOCATIONS.
58.2 GRAVEL AND DEBRIS ACCUMULATION IN EXPANSION JOINTS.
58.3 MODIFIED CONCRETE WEARING SURFACE. APPROXIMATELY 600
SQFT AREA OF CRACKING WITH DELAMINATION ALONG
CENTERLINE AT 240' FROM EAST END. UP TO 10'L X 18"W AREAS
OF DELAMINATION ALONG BOTH CURBS.
58.5 HAIRLINE SHRINKAGE CRACKING THROUGHOUT CURB; SOME WITH
MINOR EFFLORESCENCE.
58.6 ACTIVE WATER LEAKAGE THROUGH BASE OF SOME RAIL POSTS
AND HARDWARE AT UNDERSIDE OF BRIDGE OVERHANG.
59.2 MODERATE WATER LEAKAGE IN SPAN #4 AT CLOSURE POUR
BETWEEN SEGMENTS 4-10D AND 3-10U, EAST WALL. MINOR
WATER LEAKAGE AT JOINTS OF SEGMENTS 2-10U; SPAN #3 AND AT
3-9U, WEST WALL; SPAN #4. SEVERAL SEGMENT JOINTS NEAR
PIER #3 IN SPAN #4 HAVE OPENED. LARGEST OPENING IS 0.060" AT
BOTTOM BETWEEN SEGMENTS 3-2U AND 3-3U. (NOT VERIFIED IN
THIS INSPECTION).
60.5,9 4'H X 5'L X4'W EXPOSED WEST ABUTMENT FOOTING DUE TO
EROSION.
BREASTWALLS OR COLUMNS1. G
PILE BENTS2. N
CAPS AND/OR BEARING SEATS3. G
BACKWALLS AND/OR BULKHEADS4. G
FOUNDATIONS5. (PILES) G
WINGWALLS6. G
WEEP HOLES7. G
EXPANSION JOINTS8. G
EROSION AND/OR SCOUR9. G
SETTLEMENT OR DEFLECTION10. F
SLOPE PROTECTION11. G
OTHER 12. N
PIER(S)
WALLS AND/OR COLUMNS 13. G
PILE BENTS14. N
CAPS AND/OR BEARING SEATS15. G
FOUNDATIONS16. (PILES) G
EROSION AND/OR SCOUR17. G
SETTLEMENT OR DEFLECTION18. G
OTHER 19. N
222.4 MINOR CRACKING OF WEARING SURFACE AT APPROACHES.
9. STREAM BED COMPOSITION :
222. APPROACHES 7
OTHER 9.
ALIGNMENT 8.
SIGNS7.
SETTLEMENT 6.
EROSION5.
SURFACING4.
APPROACH GUARDRAIL 3.
2. RELIEF JOINTS
APPROACH SLABS1. G
N N G G G N N N
223. RETAINING WALL N
OTHER 6.
SETTLEMENT OR DEFLECTION5.
EROSION AND/OR SCOUR4.
FOUNDATION3.
WEEP HOLES2.
1. WALL
36. TRAFFIC AND SAFETY FEATURES
APPROACH GUARDRAIL ENDSD.
APPROACH GUARDRAILSC.
TRANSITIONSB.
BRIDGE RAILINGSA.
N N N
TRAFFIC SAFETY RATING CODES
N
Does not meet standards or a safety feature is required and none is provided.
Meets currently acceptable standards.
Not applicable or a safety feature is not required.
INSPECTION DATE: 5/13/14
STRUCTURE NO. 5460-214P FIELD INSPECTION REPORT
BRIDGE #2
ITEM REFERENCE AND REMARKS
AVERAGE CLEAR OPENING 8.
7. NORMAL VELOCITY
ADEQUACY OF OPENING 6.
5. OTHER
4. WATERWAY OBSTRUCTIONS
CHANNEL PROTECTION3.
EROSION AND/OR SCOUR2.
ALIGNMENT1.
61. CHANNEL N
STRUCTURE LOAD RATING STRUCTURE NO. 5460-214P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H
HS
TYPE 3
TYPE 3S2
TYPE 3-3
DESIGN LOADING:
X CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION:
LOAD RATING CONTROLLED BY:
REMARKS:
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5460-214P
STRUCTURE IDENTIFICATION
(201) PARK: GREAT SMOKY MOUNTAINS NATIONAL PARK
(202) STRUCTURE NAME: .......... BRIDGE #2
(203) STRUCTURE KIND: ............ 1 - BRIDGE
(204) STRUCTURE NUMBER: ..... 5460-214P
(205) NPS REGION: .................... 4 - SOUTHEAST
(206) ROUTE CODE NUMBER: ... 0
(207) ROAD SECTION NO: .......... 214P
(208) NPS ROAD CLASS: ............ 6 - RESTRICTED
(209) WITHIN NPS BNDRY?: ....... YES
(210) OPERATING UNIT: ............. PARK
(211) PROJECT NO(S): ................ PRA-FOOT 8E17
(212) DRAWING NUMBERS: ....... 133/100030
(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE
(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE
(1) STATE:
(2) STATE HWY. AGENCY DIST:
(3) COUNTY CODE:
(4) CITY/PLACE CODE:
(5) INVENTORY ROUTE:
(6) FEATURES INTERSECTED:
(7) FACILITY CARRIED:
(8) STATE STRUCTURE NO:
(9) LOCATION:
(10) INV. RTE. - MIN. VERT. CLR: ..
(11) MILE POINT:
(27) YEAR BUILT:
(106) YEAR RECONSTRUCTED:
(20) TOLL:
(37) HISTORICAL DESIGNATION: ..
474 - TENNESSEE (TN)
155 - SEVIER
161000000
RAVINE
FOOTHILLS PARKWAY
5460214P0000000
3.0 miles west of Route 3
99.99 FT (99.99 M)
28.00 (KM PT 45.06)
N/A
3 - FREE ROAD
5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
6 - P/S CONCRETE CONTINUOUS
21 - SEGMENTAL BOX GIRDER
180.0 FT (54.9 M)
790.0 FT (240.8 M)
3 - SPREAD FOOTING ON PILES
3 - SPREAD FOOTING ON PILES
3 - SPREAD FOOTING ON PILES
6 - N/A
2 - CONCRETE PRECAST PANELS
(44A) APPR. STR. MATERIAL: ........ 0 - OTHER
(44B) APPR. STR. TYPE: ................ 00 - OTHER
(46) NO. OF APPROACH SPANS: .. 0
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. 3 - MODIFIED CONCRETE
B) TYPE MEMBRANE: ................. 0 - NONE
C) TYPE PROTECTION: .............. 0 - NONE
(218) IS SALT USED?: ..................... NO
LOAD RATING AND POSTING
(31) DESIGN LOAD: ................. (41) LOAD RESTRICTION: ......... G - NEW STRUCTURE, NOT OP
(66) INVENTORY RATING: ...... (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED
(64) OPERATING RATING:
INSPECTION DATES
(90) INSPECTION DATE: 5/14 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO
INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5460-214P
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE: ............................. (51) CURB TO CURB WIDTH: ........... 34.0 FT (10.4 M)
(17) LONGITUDE: ......................... (52) DECK WIDTH: ............................ 36.8 FT (11.2 M)
(19) DETOUR LENGTH: ............... 0 MI (0 KM) (32) APPR. ROADWAY WIDTH:
(28A) LANES ON STRUCT: .......... 02 (213) APPR. PAVEMENT WIDTH:
(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER:
(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER:
(42B) SERVICE UNDER: .............. 0 - OTHER (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN
(29) AVG. DAILY TRAFFIC: .......... 1 (34) SKEW ANGLE: ............................ 0 °
(30) YEAR OF ADT: ...................... 2012 (35) DECK FLARE?: ........................... NO
(114) FUTURE ADT: ..................... 1 (47) TOTAL HORIZ. CLEARANCE: .... 34.0 FT (10.4 M)
(115) YEAR OF FUTURE ADT: ..... 2032 (50) SIDEWALKS:
(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)
(38) NAVIGATION CONTROL?: ... 0 RIGHT : ................................... 0.0 FT (0.0 M)
(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:
(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 1 - FULL HEIGHT (NO PARAPE
(111) ABUT. OR PIER PROT: ....... MATERIAL: .............................. 4 - STEEL
DESIGN TYPE: ........................ 1 - CONTINUOUS RAIL
LATERAL UNDERCLEARANCE:
(55) RIGHT: ....................... 0.0 FT (0.0 M) (215) BRIDGE RAIL HEIGHT: ............ 3.00 FT (0.91 M)
(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)
(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:
(59) SUPERSTRUCTURE:
(60) SUBSTRUCTURE:
(61) CHANNEL: .......................... N
(62) CULVERT: ........................... N
(222) APPROACHES:
(223) RETAINING WALL: ........... N
(36) TRAFFIC SAFETY FEAT: ...
(75A) TYPE OF WORK:
(75B) WORK DONE BY:
(76) IMPROVEMENT LENGTH: ..
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:
(225) PURPOSE OF IMPROVEMENT:
(226) PRIORITY OF IMPROVEMENT:
(227) MAINTENANCE COST:
(228) REHAB./RECONSTR. COST: ...
(229) CONSTRUCTION COST:
N
N - Not over waterway.
2 - REHAB/RECONSTRUCTION
D - MINOR
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
(231) ADDITIONAL CONSIDERATIONS:
KEY and/or COMBINATION REQUIRED TO ACCESS THIS PORTION OF THE FOOTHILLS PARKWAY UNTIL ROAD IS OPEN TO THE
PUBLIC. KEY ALSO REQUIRED TO GAIN ACCESS TO INTERIOR OF BOX GIRDER.
(330) ADDITIONAL CONFIG. INFO.:
APPENDIX STRUCTURE NO. 5460-214P
PHOTOGRAPHS STRUCTURE NO. 5460-214P
PHOTO #1 - LOOKING EAST
PHOTO #2 - SOUTH SIDE
PHOTO #3 - GENERAL TOP SIDE VIEW
LOOKING WEST, NEAR EAST END
PHOTO #4 - DELAMINATION ALONG CRACKING
OF DECK SURFACE, APPROXIMATELY 220'
FROM EAST END
PHOTO #5 - CRACKING OF WEARING SURFACE AT EAST SPAN NEAR
EAST END
PHOTO #6 - DELAMINATION ON SPOTS ALONG BOTH CURBS; NOTE
ALSO TYPICAL VERTICAL CRACKING WITH EFFLORESCENCE OF
CONCRETE CURBS, SOUTH CURB NEAR EAST END SHOWN
PHOTO #7 - TYPICAL DEBRIS ACCUMULATION
IN EXPANSION JOINTS, JOINT OVER EAST
ABUTMENT SHOWN
PHOTO #8 - STEEL PLATE UTILIZED FOR
PROTECTION AGAINST CONSTRUCTION
TRAFFIC OVER WEST EXPANSION JOINT AT
WEST END
PHOTO #9 - TYPICAL CONDITIONS OF RAIL POSTS; NOTE RUBBER PAD
AT BASE OF POST
PHOTO #10 - TRANSVERSE CRACKING ON APPROACH SLAB NEAR
EAST END
PHOTO #11 - GENERAL UNDERSIDE VIEW
FROM SPAN #1, LOOKING WEST
PHOTO #12 - UNDERSIDE VIEW OF SPAN #4,
LOOKING EAST
PHOTO #13 - TYPICAL OVERHANG CONDITION,
NORTH OVERHANG ON SPAN #1 SHOWN
PHOTO #14 - TYPICAL WATER STAINING FROM
ACTIVE WATER LEAKAGE THROUGH RAILING
ANCHORAGE
PHOTO #15 - GENERAL VIEW OF EAST ABUTMENT; NOTE RIPRAP FOR
SLOPE PROTECTION
PHOTO #16 - NORTH BEARING AT EAST ABUTMENT, TYPICAL
PHOTO #17 - ACCESS TO BOX GIRDER NEAR
EAST ABUTMENT
PHOTO #18 - UNDERSIDE VIEW OF WEST
DECK EXPANSION JOINT ASSEMBLY
PHOTO #19 - WEST END OF BOX BEAM
PHOTO #20 - GENERAL VIEW OF WEST
ABUTMENT; NOTE SLOPE PROTECTION AT
ABUTMENT
PHOTO #21 - EROSION AT SOUTH END OF WEST ABUTMENT; NOTE
FOOTING EXPOSED ABOUT 4 FEET HEIGHT X 5 FEET LONG
PHOTO #22 - STEEP SLOPE AT SOUTH SIDE, WEST END SHOWN
PHOTO #23 - GENERAL VIEW OF PIER #1 EAST FACE
PHOTO #24 - ELASTOMERIC BEARING PADS ON PIER #1
PHOTO #25 - TYPICAL BASE OF PIER; NOTE
EXPOSED FOOTING
PHOTO #26 - GENERAL VIEW OF PIER #3;
NOTE RIPRAP PROTECTION AT SOUTH SIDE
PHOTO #27 - NORTHEAST WINGWALL
PHOTO #28 - TEMPORARY DRAINAGE PIPE
FROM ADJACENT CONSTRUCTION SITE
ALONG NORTHWEST WINGWALL
PHOTO #29 - EFFLORESCENCE AT
SOUTHEAST WINGWALL
PHOTO #30 - CLOGGED WEEP HOLE AT
SOUTHEAST WINGWALL
File details come from the government source that posted it. Updated .