DRAWINGS SECTION VII DKX REROOF IFB 02_04_2025.pdf
PDF 2 MB Posted
- Solicitation number
- IFB-MKAA-0000000003
- Issued by
- Bradley County, Tennessee
About this file
These are architectural drawings for the Metro Knoxville Airport Authority (MKAA) Hanger Reroof project located at 2701 Spence Pl., Knoxville, TN 37920, prepared by McCarty Holsaple McCarty Architects with project number 25004 and issued on February 4, 2025. The project consists of two separate bid items: Bid Item 01 involves reroofing the Museum Hanger, which includes selective demolition, installing new metal roofing panels, roof light panels, building insulation, and related accessories, along with miscellaneous interior improvements and repair/painting of the hangar structural frame. Bid Item 02 involves reroofing the Maintenance Building, which includes selective demolition, installing new metal roofing panels, coping, roof skylights, building insulation, and related accessories.
The drawings provide detailed technical specifications for the roofing work, including roof plan layouts, general notes, keyed notes, and specific installation details for both hangar buildings. The project involves replacing existing metal roof systems, insulation, and associated components while maintaining the structural integrity of the buildings. Structural repairs, surface rust removal, and repainting are specified, and the work includes coordination with existing building systems and infrastructure. The project appears to be funded by the Metro Knoxville Airport Authority and will require careful coordination to minimize disruption to airport operations.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SYMBOLS LEGEND
?A2
ROOM NAME
A101A
PROJECT GENERAL NOTES
PROJECT BID PACKAGES
OWNER COORDINATION
1. VERIFY THE BUILDING'S RULES FOR CONSTRUCTION WITH THE OWNER.
2. KEEP DRIVEWAYS, DOCKS AND ENTRANCES SERVING THE PREMISES CLEAR AND AVAILABLE TO THE LANDLORD AND THE OWNER'S TENANTS AND VENDORS AT ALL TIMES. DO NOT USE THESE AREAS FOR PARKING OR STORAGE OF MATERIALS.
SCHEDULE DELIVERIES TO MINIMIZE SPACE AND TIME REQUIREMENTS FOR STORAGE OF MATERIAL AND EQUIPMENT ON SITE.
3. THE CONTRACTOR SHALL MAKE ALL ARRANGEMENTS WITH THE OWNER PERTAINING TO THE USE OF THE BUILDING ENTRANCES, ELEVATORS, WORKING HOURS, NOISY WORK, ACCESS TO ADJACENT SPACES, SECURITY, OWNERSHIP OF
SALVAGED ITEMS AND OTHER ITEMS DEEMED TO BE OF MUTUAL INTEREST.
4. AVOID INTERRUPTION OF SERVICES (ELECTRICAL, SIGNAL, MECHANICAL, FIRE PROTECTION, LIFE SAFETY, PLUMBING, ETC.) TO OCCUPIED AREAS OF THE BUILDING DURING CONSTRUCTION. IF SERVICE INTERRUPTIONS ARE UNAVOIDABLE, THE CONTRACTOR SHALL NOTIFY AND OBTAIN APPROVAL FROM THE OWNER AND TENANT AT LEAST 24 HOURS PRIOR TO
PROCEEDING SUCH WORK.
5. ALL WORK SHALL CONFORM TO ALL INDUSTRY AND MANUFACTURERS' PUBLISHED STANDARDS AND THE OWNER'S REQUIREMENTS FOR QUALITY OF MATERIALS AND WORKMANSHIP AS WELL AS ALL REQUIREMENTS IN THE DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE TO BECOME FAMILIAR AND COMPLY WITH THE LANDLORD'S STANDARD DETAILS OF CONSTRUCTION. ANY CONFLICTING REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT TO THE ATTENTION
OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.
6. PENETRATIONS IN THE EXTERIOR BUILDING WALL ARE NOT ALLOWED, INCLUDING THOSE FOR OUTLETS AND BLOCKING, UNLESS
EXPRESSLY ALLOWED BY THE OWNER.
7. ALL PENETRATIONS IN FLOOR SLABS MUST BE APPROVED BY THE OWNER.
PERMITS AND SAFETY
1. THE CONTRACTOR FOR THE PROJECT SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED BUILDING PERMITS.
2. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE PUBLIC AND THE WORKMEN ON THE JOB AND TO PREVENT ACCIDENTS OR INJURY TO ANY PERSONS ON, ABOUT, OR ADJACENT TO THE PREMISES WHERE THE WORK IS BEING PERFORMED. THE CONTRACTOR SHALL COMPLY WITH ALL OF THE LAWS, ORDINANCES, CODES, RULES AND
REGULATIONS RELATIVE TO SAFETY AND THE PREVENTION OF ACCIDENTS.
3. PROVIDE ALL NECESSARY TEMPORARY POWER, LIGHTING, FIRE PROTECTION, ETC, AS REQUIRED DURING CONSTRUCTION.
4. THE CONTRACTOR SHALL PROVIDE TEMPORARY WALLS, AS REQUIRED, TO ENCLOSE AND BARRICADE FOR SAFETY, AND FOR LOCALIZING AND MINIMIZING DUST AND NOISE FROM ANY OPERATIONS AND TO EFFECTIVELY SEPARATE WORK AREA FROM
OTHER OCCUPIED AREAS OF THE BUILDING.
5. DO NOT OBSTRUCT ACCESS TO EXISTING EXITS OR REDUCE THE WIDTH OF EXIT ACCESS CORRIDORS AND HALLWAYS.
CONSTRUCTION COORDINATION
1. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PARTS OF THE WORK STATED OR IMPLIED SO THAT NO
WORK IS LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION.
2. WHERE SPECIAL COORDINATION IS NECESSARY, PREPARE MEMORANDA FOR DISTRIBUTION TO EACH PARTY INVOLVED OUTLINING SPECIAL PROCEDURES REQUIRED FOR COORDINATION. INCLUDE SUCH ITEMS AS REQUIRED NOTICES, REPORTS, AND ATTENDANCE AT MEETINGS.
3. COORDINATE CONSTRUCTION ACTIVITIES INDICATED ON CONTRACT DOCUMENTS TO ASSURE EFFICIENT, ORDERLY, COMPLETE AND OPERATIONAL INSTALLATIONS OF EACH PART OF THE WORK. COORDINATE CONSTRUCTION OPERATIONS THAT ARE DEPENDENT UPON EACH OTHER FOR PROPER INSTALLATION, CONNECTION, AND OPERATION. WHERE MATERIALS APPLIED TO, OR ARE IN DIRECT CONTACT WITH, WORK INSTALLED BY ANOTHER SUBCONTRACTOR, COMMENCEMENT OF WORK IMPLIES
ACCEPTANCE OF THE SUBSTRATE AS SUITABLE FOR THE APPLICATION INTENDED.
4. CONFINE OPERATIONS TO AREAS WITHIN CONTRACT LIMITS INDICATED. PORTIONS OF THE SITE BEYOND AREAS IN WHICH
CONSTRUCTION IS INDICATED ARE NOT TO BE DISTURBED.
5. WHERE AVAILABILITY OF SPACE IS LIMITED, COORDINATE INSTALLATION OF DIFFERENT COMPONENTS TO ASSURE MAXIMUM
ACCESSIBILITY OF REQUIRED MAINTENANCE, SERVICE AND REPAIR.
6. COORDINATE TRADES TO PATCH FINISHES THAT ARE DAMAGED AS A RESULT OF CUTTING IN OF WORK.
7. COORDINATE INSTALLATION OF DIFFUSERS, SPEAKERS, SPRINKLER HEADS, AND ACCESS PANELS WITH LIGHTING LAYOUT.
REPORT ANY CONFLICTS TO THE ARCHITECT PRIOR TO INSTALLATION.
CONTRACT DOCUMENTS
1. REFER TO COMPLETE SET OF ISSUED CONTRACT DOCUMENTS FOR APPLICABLE NOTES, ABBREVIATIONS, AND SYMBOLS.
GENERAL NOTES APPEAR ON VARIOUS DRAWINGS FOR DIFFERENT SYSTEMS AND MATERIALS. REVIEW ALL SHEETS AND APPLY
NOTES TO RELATED BUILDING COMPONENTS.
2. DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND ARE INTENDED TO INCLUDE OR IMPLY ALL ITEMS REQUIRED FOR
THE PROPER EXECUTION AND COMPLETION OF THE WORK.
3. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING OF ANY OMISSIONS, DISCREPANCIES, AND/OR CONFLICTS IN THE DRAWINGS AND SPECIFICATIONS BEFORE SUBMITTING HIS BID PRICE. THE ARCHITECT WILL CLARIFY THE DOCUMENTS IN AN ADDENDUM. IF ANY ADDENDUM IS NOT ISSUED BEFORE THE BID/PRICE IS SUBMITTED, THE CONTRACTOR'S BID/PRICE SHALL BE BASED ON THE HIGHER QUANTITY AND/OR HIGH QUALITY AND SHALL BE SO NOTED IN HIS BID/PRICE.
4. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.
5. LARGE SCALE DRAWINGS GOVERN OVER SMALL SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, OBTAIN CLARIFICATION
FROM THE ARCHITECT BEFORE CONTINUING.
6. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, BENCHMARKS, WORKPOINTS, SPOT ELEVATIONS AND CONDITIONS SHOWN ON THE DRAWINGS AT THE JOB SITE AND SHALL NOTIFY THE ARCHITECT OF ANY OMISSIONS, DISCREPANCIES, AND/OR
CONFLICTS BEFORE PROCEEDING WITH THE PROJECT.
7. FINISH FLOOR ELEVATIONS ARE TO TOP OF CONCRETE SLAB UNLESS OTHERWISE NOTED.
8. FIELD MEASURE AND CONFIRM DIMENSIONS FOR O.F./C.I. EQUIPMENT.
9. EXIT SIGNS AND SMOKE DETECTORS LOCATED IN HARD CEILINGS SHALL BE POSITIONED AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION AND SHALL BE CENTERED IN CORRIDORS AND LOCATED A DISTANCE OF 1'-0" FROM THE WALL TO THE
CENTER OF THE FIXTURE UNLESS OTHERWISE NOTED.
10. EQUIPMENT AND FURNITURE SHOWN ARE NOT INCLUDED IN CONTRACT, UNLESS OTHERWISE NOTED.
CONSTRUCTION
1. NEW AND EXISTING OPENINGS IN RATED WALL, FLOOR, CEILING, AND ROOF ASSEMBLIES SHALL BE SEALED WITH PENETRATION SEALANT SYSTEMS MEETING OR EXCEEDING THE REQUIRED FIRE RESISTIVE RATINGS, OR PROTECTED WITH A FIRE RATED
CHASE.
2. MAINTAIN THE FIRE RATING OF CONSTRUCTION AROUND CABINETS, PANELS, AND BOXES RECESSED IN RATED WALL, FLOOR, AND CEILING ASSEMBLIES.
3. APPROVE FLOOR OUTLET LOCATIONS WITH ARCHITECT AND OWNER PRIOR TO CORE DRILLING.
4. PROVIDE NON-COMBUSTIBLE STIFFENERS, BRACING, BACKING PLATES AND BLOCKING REQUIRED FOR SECURE INSTALLATION OF DOORS AND DOOR HARDWARE INCLUDING WALL-MOUNTED DOOR STOPS, MILLWORK, HANDRAILS, WALL-MOUNTED SHELVES, OPERABLE PARTITIONS, MISCELLANEOUS EQUIPMENT, AND SUSPENDED MECHANICAL AND ELECTRICAL EQUIPMENT.
5. LEVEL FLOOR THAT EXCEED 1/4" VARIANCE IN A 10'-0" RADIUS.
6. ISOLATE DISSIMILAR METALS TO PREVENT GALVANIC CORROSION.
7. ALL EXTERIOR STEEL HANDRAILS, GUARDRAILS, AND BOLLARDS SHALL BE GALV. AND PAINTED, UNLESS OTHERWISE NOTED.
8. PIPING LOCATED ABOVE GRADE AND INSIDE THE BUILDING SHALL BE CONCEALED IN FURRED SPACES WITH THE EXCEPTION OF PIPING IN STAIRWAYS, EQUIPMENT ROOMS AND POWERHOUSE. COORDINATE WITH OTHER TRADES TO PROVIDE FURRING FOR
PIPING INSTALLED IN FINISHED AREAS.
9. PROVIDE CONTINUOUS PERIMETER FIRE SAFING BETWEEN FLOORS AND COORDINATE THE INSTALLATION WITH THE EXTERIOR
WALL. FIRE RATING OF SAFING SHALL MATCH FIRE RATING OF FLOOR CONSTRUCTION.
EXISTING AND COMPLETED WORK
1. CLEAN AND PROTECT CONSTRUCTION IN PROGRESS AND ADJOINING MATERIALS IN PLACE. APPLY PROTECTIVE COVERING WHERE REQUIRED TO ENSURE PROTECTION FROM DAMAGE OR DETERIORATION. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO ALL EXISTING CONDITIONS AND COMPLETED WORK WHILE FULFILLING THE OBLIGATIONS OF THIS CONTRACT.
2. CLEAN AND MAINTAIN COMPLETED CONSTRUCTION AS FREQUENTLY AS NECESSARY THROUGH THE DURATION OF THE
CONSTRUCTION PERIOD.
KEYNOTE NUMBER
ROOM NAME & NUMBER
LEVEL INDICATOR
EXISTING GRID MARK
AND LINE
NEW GRID MARK
AND LINE
A-XXX
X##
X## X##
X##
A-XXX
X
INTERIOR ELEVATION
NUMBER & SHEET NUMBER
ENLARGED VIEW
NUMBER & SHEET NUMBER
EXTERIOR ELEVATION
NUMBER & SHEET NUMBER
SECTION VIEW
NUMBER & SHEET NUMBER
A-XXX
X
A-XXX
X
SITE VICINITY MAPS
SHEET NUMBERA-121
DISCIPLINE DESIGNATOR
DASH OR DISCIPLINE MODIFIER
SHEET TYPE DESIGNATOR
SHEET SEQUENCE NUMBER
GRID MARKS
HORIZONTAL SPOT
ELEVATION
+X'-X"
1 REVISION NUMBER
PROJECT NORTH INDICATOR
DETAIL NUMBER
CODE INFORMATION
LEVEL XX
10'-0"
B
A
A24
1/8" = 1'-0" | A-101 | SUB-TITLE
VIEW NAME
SCALE
SHEET NUMBER
TRUE NORTH
PROJECT NORTH
SITE PLAN LEGEND
SHEET INDEX
Checked By:
Drawn By:
PA
PM
Project Information:
Consultant:
Sheet Information:
Copyright © 2024 McCarty Holsaple McCarty
# ISSUED BY: DATE
PIC
Issue Date:
2055 ALCOA HWY
ALCOA TN. 37701
McCarty Holsaple McCarty 550 W. Main St., Suite 300 Knoxville, TN 37902 t 865.544.2000 www.mhminc.com
010203040506070809101112131415161718192021222324
010203040506070809101112131415161718192021222324
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
PROJECT NO.:
/3
/2
:0
:1
P M
G-001
SHEET INDEX
M. MCNABB
PROJECT STATUS
A. BUCHANAN
C. MYERS
C. MYERS
25004
MKAA DKX
HANGER REROOF
METRO KNOXVILLE
AIRPORT AUTHORITY
2701 SPENCE PL. KNOXVILLE, TN
37920
N. HONEYCUTT
FEBRUARY 04, 2025
PROJECT STATUS FOR
ISSUED: FEBRUARY 04, 2025
MKAA DKX HANGER REROOF
METRO KNOXVILLE AIRPORT AUTHORITY
2701 SPENCE PL. KNOXVILLE, TN 37920
25004
ARCHITECTURE:
McCARTY HOLSAPLE McCARTY
ARCHITECTS, INC.
550 W. MAIN STREET, STE. 300
KNOXVILLE, TN 37902
865.544.2000 www.mhminc.com
Nathan Honeycutt email@domain.com
STRUCTURAL:
ROSS BRYAN ASSOCIATES, INC.
227 FRENCH LANDING DRIVE, ste 500
NASHVILLE, TN 37228
615.329.1300 www.rossbryan.com
Jacob Holloway holloway@rossbryan.com
SHEET
NO. SHEET DESCRIPTION
ISSUE
DATE
REV
NO. ISSUED BY
REVISION
DATE
GENERAL
G-001 SHEET INDEX 02/04/2025
ARCHITECTURAL
A-101 BID ITEM 01 MUSEUM HANGER ROOF PLAN 02/04/2025
A-102 BID ITEM 02 MAINTENANCE HANGER ROOF PLAN 02/04/2025
Local Regulations:
ZONE:
BUILDING SETBACKS: FRONT:
SIDE1:
REAR:
LOT COVERAGE:
MAXIMUM HEIGHT ALLOWABLE:
SIDE2:
ALLOWABLE NUMBER OF STORIES:
PARCEL:
EASEMENTS:
ADJACENT PROPERTY USE:
PARKING:
Parking Spaces Required:
Handicap Spaces Required:
Parking Space Size Requirement:
LANDSCAPING / SCREENING:
SITE DRAINAGE / RUN-OFF &
RETENTION REQUIREMENTS:
INST
East :
South :
0' - 0"
West :
North :
095MC014
note note
9'-0" W x 18'-0" D
Landscaped and maintained in a neat condition note
20' - 0"
0' - 0"
0' - 0"
20' - 0"
Construction Classification:
Occupancy Classification: (IBC Ch. 3, LSC Ch. 4) Occupancy Type (IBC 302.1):
Hazard Type (LSC 6-2):
Fire District:
Building Description:
Type IIB
S-1 STORAGE
KNOXVILLE FIRE DEPARTMENT
REMOVING AND REPLACING DAMAGED METAL ROOFS ON THE AIRPLANE
MAINTENANCE HANGER AND THE MUSEUM HANGER WITH LIKE MATERIALS.
Applicable Codes:
2018 International Building Code (IBC)
2018 International Fire Code
2018 International Plumbing Code (IPC)
2018 International Mechanical Code (IMC)
2018 International Fuel Gas Code (IFGC)
2018 International Energy Code (IECC)
2011 National Electrical Code
2009 American National Standards Institute A117.1 (ICC/ANSI)
2018 International Existing Building Code (IEBC)
CODE SYNOPSIS
N/A
N/A
N/A
N/A
Seal:
BID ITEM # 01:
REROOF MUSEUM HANGER
REFERENCE SHEET A-101
BID ITEM NUMBER 01 CONTAINS THE REROOF OF THE MUSEUM
HANGER ROOF, AS WELL AS AN UPGRADE/REPAIR TO THE
EXISTING OFFICE SPACE AS SHOWN ON THE DRAWINGS.
ALTERNATE - OPTION TO REPLACE LIGHTS AND WINDOW
TREATMENTS IN OFFICE AREA.
BID ITEM # 02:
REROOF MAINTENANCE HANGER
REFERENCE SHEET A-102
BID ITEM NUMBER 02 CONTAINS THE REROOF OF THE
MAINTENANCE HANGER ROOF.
ALTERNATE - NO ALTERNATES THIS OPTION.
PROJECT STATUS
ROOF PLAN GENERAL NOTES
ROOF PLAN KEYED NOTES
ROOF PLAN LEGEND
1. ALL ROOF MEMBRANE AREAS SHALL BE SLOPED A MINIMUM 1/4" SLOPE
PER FOOT UNLESS NOTED OTHERWISE. REFER TO BUILDING SECTIONS
AND STRUCTURAL DWGS FOR SLOPING STRUCTURE.
2. ALL CRICKETS SHALL HAVE A MINIMUM 1/4" NET SLOPE PER FOOT, UNLESS
NOTED OTHERWISE. USE 1/2" MATERIAL SLOPE PER FOOT TAPERED
INSULATION ON STRUCTURALLY SLOPED ROOFS TO ACHIEVE A MINIMUM
1/4" NET SLOPE PER FOOT.
3. ARROWS INDICATE DIRECTION OF DOWNWARD ROOF SLOPE.
4. PROVIDE CRICKETS AT ALL ROOF TOP EQUIPMENT / PROTRUSIONS / ETC.
TO ENSURE POSITIVE DRAINAGE.
5. ALL NEW AND EXISTING PENETRATIONS TO BE FLASHED AND SEALED PER
MANUFACTURER.
6. COORDINATE ALL PENETRATIONS WITH PLUMBING, MECHANICAL AND
ELECTRICAL DRAWINGS.
7. REFER TO STRUCTURAL REPORT AND SPECIFICATIONS FOR AREAS OF
STRUCUTRAL REPAIRS/PAINT. REMOVE SURFACE RUST PRIOR TO
REPAINTING STRUCTURAL MEMBERS. CONTACT STRUCTURAL ENGINEER
FOR GUIDANCE IF EXCESSIVE CORROSION IS ENCOUNTERED.
DIRECTION OF DOWNWARD SLOPE
EXPOSED FASTENER METAL ROOF
SYSTEM TO BE DEMOLISHED AND
REPLACED.
EXISTING EXHAUST PIPE FOR SPACE
HEATERS. CAP OR REPAIR.
ROOF AREA NOT IN SCOPE
SLOPE
1/4" / FT
INDICATES EXISTING DOWNSPOUT
LOCATION
"DS"
DSDSDSDS
DSDSDSDS
DS
DS
A7
A1
A6
A5
TYP.
TYP.
TYP.
'-0
100'-0"
A-101
P11
A15
A14
TYP.
A16
TYP.
A8
A13
A9
A9
A12
A10
10'-0" 20'-0"
'-0
A9
PIPE MATERIAL (EXISTING). FIELD
CUT THE PIPE BOOT TO FIT SNUG.
ROOF PANEL
PIPE BOOT. PLACE A FASTENER AT EACH
HOLE. THE FASTENERS MUST PENETRATE
THE TAPE MASTIC TO CREATE AN EFFECTIVE
SEAL. (PIPE BOOT BASE MAY BE SQUARE, AS
SHOWN, OR ROUND)
PLACE 3/4" TAPE MASTIC UNDER THE
FULL PERIMETER OF THE PIPE BOOT.
CAULK AROUND THE PERIMETER WITH
TUBE CAULK TO CREATE A
WEATHERTIGHT SEAL.
IF IT FITS BETWEEN THE MAJOR RIBS,
IT IS RECOMMENDED TO ROTATE THE
PIPE BOOT 45° FROM WHAT IS SHOWN
6"
FASTENERS AT 6" O.C MAXIMUM
TRANSLUCENT PANEL
(SHOWN CUT-AWAY FOR CLARITY)
UPSLOPE PANEL
ROOF PURLIN
SIDE STRAP UNDER BOTH
SIDELAPS (THE STRAP DOES
NOT ATTACH TO THE
PURLINS)
UP SLOPE
3/4" TAPE MASTIC AT SIDELAP
PREVIOUS PANEL
RUN
ROOF PANEL
TRIM WITH 3/4" TAPE
MASTIC BELOW
(SHOWN CUT-AWAY
FOR CLARITY)
STRAPS WITH 3/4"
TAPE MASTIC
BETWEEN STRAP AND
PANEL
(FULL WIDTH OF
PANEL)
GUTTER HANGER @ 2'-0" O.C.
w/ (3) FASTENERS
GUTTER, EXISTING TO BE
REUSED
FASTENERS @ 12" O.C.
ROOF INSULATION
LOW EAVE FLASHING w/ FASTENERS @ 1'-0" O.C.
(2" LAP WITH POLYURETHANE CAULK)
1/2" TAPE MASTIC
EAVE MEMBER
WALL INSULATION
WALL PANEL
INSIDE PANEL CLOSURE WITH 3/4" TAPE
MASTIC TOP AND BOTTOM
METAL PANEL ROOF
3/4" TAPE MASTIC, CONTINUOUS
3/4" TAPE MASTIC (6" PIECE) DIRECTLY
BELOW FASTENERS
P A
N E
L T
O E
A V
E
T
O P
O F
5 1/4"
RIDGE CAP
AT EACH RIDGE CAP SIDELAP
INSTALL 1/2" TAPE MASTIC WITH (6)
FASTENERS EQUALLY SPACED
ROOF INSULATION
C L
5 1/4" 5 1/4"
1'-4"
FASTENER, REFER
TO MANUFACTURER
FOR SPACING
3"
3/4" TAPE MASTIC
Checked By:
Drawn By:
PA
PM
Project Information:
Consultant:
Sheet Information:
Consultants:
STRUCTURAL ENGINEER:
ROSS BRYAN ASSOCIATES, INC.
227 FRENCH LANDING DRIVE, ste 500
NASHVILLE, TN 37228
t 615.329.1300
Copyright © 2024 McCarty Holsaple McCarty
# ISSUED BY: DATE
PIC
Issue Date:
2055 ALCOA HWY
ALCOA TN. 37701
McCarty Holsaple McCarty 550 W. Main St., Suite 300 Knoxville, TN 37902 t 865.544.2000 www.mhminc.com
010203040506070809101112131415161718192021222324
010203040506070809101112131415161718192021222324
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
/3 /2
:0
:1
P M
A-101
BID ITEM 01
MUSEUM HANGER
ROOF PLAN
M. MCNABB
PROJECT STATUS
A. BUCHANAN
C. MYERS
C. MYERS
25004
MKAA DKX
HANGER REROOF
METRO KNOXVILLE
AIRPORT AUTHORITY
2701 SPENCE PL. KNOXVILLE, TN
37920
N. HONEYCUTT
FEBRUARY 04, 2025
Seal:
A16 1/8" = 1'-0" | A-101
BID ITEM 01 - MUSEUM HANGER ROOF PLAN
P11 1/4" = 1'-0" | A-101
OFFICE - ENLARGED PLAN
A1 DEMO AND SALVAGE ALL GUTTERS AND DOWNSPOUTS FOR
REUSE. NOTIFY ARCHITECT OF ANY DAMAGE.
A5 NEW METAL ROOF, COLOR TO MATCH EXISTING, REFER TO
SPECIFICATIONS.
A6 REMOVE/REPLACE ALL ROOF INSULATION, TYP.
A7 TRANSLUCENT PANEL SKYLIGHTS TO BE REPLACED WITH LIKE
MATERIAL.
A8 DEMO OFFICE WALLS TO REVEAL STUDS FOR INSPECTION,
REPLACE WITH MOLD AND MILDEW RESISTANT GYP BOARD.
A9 DEMO EXTERIOR PANELING AND PREP FOR REPLACEMENT
WITH MOLD AND MILDEW RESISTANT GYP BOARD.
A10 DEMO OFFICE CEILING AND REPLACE WITH NEW ACT, OPTION
TO REPLACE LIGHTS AND WINDOW TREATMENTS.
A12 VERIFY DECKING STRUCTURE ABOVE, PROVIDE NEW
STRUCTURE AS NEEDED.
A13 REMOVE AND REPLACE SINK AND HANDWASH ITEMS.
A14 EXISTING HANGER DOORS AND TRACK.
A15 REPAIR/REPLACE ALL INSULATION IN EXTERIOR HANGER WALLS
UP 10' (FEET) FROM FFE.
A16 REMOVE ALL SURFACE CORROSION AND REPAINT STRUCTURE
AS INDICATED BY STRUCTURAL REPORT AND SPECIFICATIONS.
A24 3" = 1'-0" | A-101
PIPE BOOT DETAIL
G24 3" = 1'-0" | A-101
TRANSLUCENT PANEL DETAIL
P24 1 1/2" = 1'-0" | A-101
LOW EAVE GUTTER DETAIL
P18
3" = 1'-0" | A-101
RIDGE CAP DETAIL
ROOF PLAN GENERAL NOTES
ROOF PLAN KEYED NOTES
ROOF PLAN LEGEND
1. ALL ROOF MEMBRANE AREAS SHALL BE SLOPED A MINIMUM 1/4" SLOPE
PER FOOT UNLESS NOTED OTHERWISE. REFER TO BUILDING SECTIONS
AND STRUCTURAL DWGS FOR SLOPING STRUCTURE.
2. ALL CRICKETS SHALL HAVE A MINIMUM 1/4" NET SLOPE PER FOOT, UNLESS
NOTED OTHERWISE. USE 1/2" MATERIAL SLOPE PER FOOT TAPERED
INSULATION ON STRUCTURALLY SLOPED ROOFS TO ACHIEVE A MINIMUM
1/4" NET SLOPE PER FOOT.
3. ARROWS INDICATE DIRECTION OF DOWNWARD ROOF SLOPE.
4. PROVIDE CRICKETS AT ALL ROOF TOP EQUIPMENT / PROTRUSIONS / ETC.
TO ENSURE POSITIVE DRAINAGE.
5. ALL NEW AND EXISTING PENETRATIONS TO BE FLASHED AND SEALED PER
MANUFACTURER.
6. COORDINATE ALL PENETRATIONS WITH PLUMBING, MECHANICAL AND
ELECTRICAL DRAWINGS.
7. REFER TO STRUCTURAL REPORT AND SPECIFICATIONS FOR AREAS OF
STRUCUTRAL REPAIRS/PAINT. REMOVE SURFACE RUST PRIOR TO
REPAINTING STRUCTURAL MEMBERS. CONTACT STRUCTURAL ENGINEER
FOR GUIDANCE IF EXCESSIVE CORROSION IS ENCOUNTERED.
DIRECTION OF DOWNWARD SLOPE
EXPOSED FASTENER METAL ROOF
SYSTEM TO BE DEMOLISHED AND
REPLACED.
EXISTING EXHAUST PIPE FOR SPACE
HEATERS. CAP OR REPAIR.
ROOF AREA NOT IN SCOPE
SLOPE
1/4" / FT
INDICATES EXISTING DOWNSPOUT
LOCATION
"DS"
DS DS
DS DS
/8
/8
'-0
56'-0"
A1A2
A2 A1
A5
A6
A4
TYP. TYP.
TYP.
TYP.
TYP.
TYP.TYP.
A3
TYP.
A15
TYP.
GUTTER HANGER @ 2'-0" O.C.
w/ (3) FASTENERS
GUTTER, EXISTING TO BE
REUSED
FASTENERS @ 12" O.C.
ROOF INSULATION
LOW EAVE FLASHING w/ FASTENERS @ 1'-0" O.C.
(2" LAP WITH POLYURETHANE CAULK)
1/2" TAPE MASTIC
EAVE MEMBER
WALL INSULATION
WALL PANEL
INSIDE PANEL CLOSURE WITH 3/4" TAPE
MASTIC TOP AND BOTTOM
METAL PANEL ROOF
3/4" TAPE MASTIC, CONTINUOUS
3/4" TAPE MASTIC (6" PIECE) DIRECTLY
BELOW FASTENERS
P A
N E
L T
O E
A V
E
T
O P
O F
5 1/4"
R-PANEL
CLEAR OPENING1 1/2"
INSULATION
SUPPORT FRAMING
WATER DIVERTER
SUPPORT FRAMING
ROOF CURB
1 1/2"
BATT INSULATION
CURB
2 1/2" TAPE MASTIC (SUPPLIED
WITH
CURB)
RIB COVER, FASTEN WITH (9) #12 X
1/4" FASTENERS. (SUPPLIED WITH
CURB)
FASTEN PERIMETER OF
CURB FLANGE WITH #12 X
1/4" FASTENERS, 3" O.C.
(SUPPLIED WITH CURB)
1/2"1/2"
10" 3 1/2"
(LAP)
3"
END OF PANEL
EDGE OF CURB
(MIN. @ JOISTS)
3 1/2"
10"
END OF PANEL
EDGE OF CURB
(LAP)
JOIST
(MIN. @ PURLINS)
1 3/4"
PURLIN
JOIST
PURLIN
5 1/4" 3"
(MIN. @ JOISTS)
(MIN. @ PURLINS)
BACKER CHANNEL
(SUPPLIED WITH
CURB)
RIDGE CAP
AT EACH RIDGE CAP SIDELAP
INSTALL 1/2" TAPE MASTIC WITH (6)
FASTENERS EQUALLY SPACED
ROOF INSULATION
C L
5 1/4" 5 1/4"
1'-4"
FASTENER, REFER
TO MANUFACTURER
FOR SPACING
3"
3/4" TAPE MASTIC
PIPE MATERIAL (EXISTING). FIELD
CUT THE PIPE BOOT TO FIT SNUG.
ROOF PANEL
PIPE BOOT. PLACE A FASTENER AT EACH
HOLE. THE FASTENERS MUST PENETRATE
THE TAPE MASTIC TO CREATE AN EFFECTIVE
SEAL. (PIPE BOOT BASE MAY BE SQUARE, AS
SHOWN, OR ROUND)
PLACE 3/4" TAPE MASTIC UNDER THE
FULL PERIMETER OF THE PIPE BOOT.
CAULK AROUND THE PERIMETER WITH
TUBE CAULK TO CREATE A
WEATHERTIGHT SEAL.
IF IT FITS BETWEEN THE MAJOR RIBS,
IT IS RECOMMENDED TO ROTATE THE
PIPE BOOT 45° FROM WHAT IS SHOWN
Checked By:
Drawn By:
PA
PM
Project Information:
Consultant:
Sheet Information:
Consultants:
STRUCTURAL ENGINEER:
ROSS BRYAN ASSOCIATES, INC.
227 FRENCH LANDING DRIVE, ste 500
NASHVILLE, TN 37228
t 615.329.1300
Copyright © 2024 McCarty Holsaple McCarty
# ISSUED BY: DATE
PIC
Issue Date:
2055 ALCOA HWY
ALCOA TN. 37701
McCarty Holsaple McCarty 550 W. Main St., Suite 300 Knoxville, TN 37902 t 865.544.2000 www.mhminc.com
010203040506070809101112131415161718192021222324
010203040506070809101112131415161718192021222324
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
/3 /2
:0
:1
P M
A-102
BID ITEM 02
MAINTENANCE
HANGER ROOF PLAN
M. MCNABB
PROJECT STATUS
A. BUCHANAN
C. MYERS
C. MYERS
25004
MKAA DKX
HANGER REROOF
METRO KNOXVILLE
AIRPORT AUTHORITY
2701 SPENCE PL. KNOXVILLE, TN
37920
N. HONEYCUTT
FEBRUARY 04, 2025
Seal:
A15 1/8" = 1'-0" | A-102
BID ITEM 02 - MAINTENANCE HANGER ROOF PLAN
A1 DEMO AND SALVAGE ALL GUTTERS AND DOWNSPOUTS FOR
REUSE. NOTIFY ARCHITECT OF ANY DAMAGE.
A2 PAINTED FASCIA TO REMAIN.
A3 CAP OR REPAIR (4) UN-USED GAS VENT PENETRATIONS.
A4 REMOVE AND RESEAL (8) SKYLIGHTS, REWORK CURB AND
FLASHING AS NEEDED.
A5 NEW METAL ROOF, COLOR TO MATCH EXISTING, REFER TO
SPECIFICATIONS.
A6 REMOVE/REPLACE ALL ROOF INSULATION, TYP.
A15 REPAIR/REPLACE ALL INSULATION IN EXTERIOR HANGER WALLS
UP 10' (FEET) FROM FFE.
A24 1 1/2" = 1'-0" | A-102
LOW EAVE GUTTER DETAIL
H24 1 1/2" = 1'-0" | A-102
CURB FLASHING DETAIL
P24 3" = 1'-0" | A-102
RIDGE CAP DETAIL
Q10 3" = 1'-0" | A-102
PIPE BOOT DETAIL
| Sheets |
| A-101 - BID ITEM 01 MUSEUM HANGER ROOF PLAN |
| A-102 - BID ITEM 02 MAINTENANCE HANGER ROOF PLAN |
| G-001 - SHEET INDEX |
File details come from the government source that posted it. Updated .