Drawings for new ECP.pdf

PDF 964 KB Posted

Attached to
PANG Alert Guard Shack Construction
Solicitation number
S-24800-00013509
Issued by
Multnomah County, Oregon

About this file

These detailed architectural and engineering drawings by B.I.G. Enterprises document a custom-manufactured deluxe guard booth for the Portland Air National Guard (PANG), located at 6801 NE Cornfoot Rd. in Portland, Oregon. The guard booth is an 8'-0" x 17'-0" x 9'-8" single-story prefabricated structure with 136 square feet of interior space, engineered to meet Underwriters Laboratories UL752 Level 3 bullet-resistant standards. Key design specifications include a bullet-resistant exterior with half-glazed walls, R-22.6 insulation value, a 12-gauge galvanized steel floor, a 16-gauge galvanized steel roof sloped 1/4" per 12", and comprehensive features such as a sliding door, HVAC system, electrical infrastructure, and a fully equipped restroom.

The drawings provide comprehensive technical details for a turnkey installation, specifying structural, mechanical, electrical, and plumbing requirements. The guard booth includes advanced features like a Mitsubishi ductless ceiling cassette split system, LED lighting, GFCI receptacles, an exhaust fan, and a restroom with standard fixtures to be installed on-site. The structure is designed for maximum durability and functionality, with weather-proofing that includes a three-step elastomeric roof membrane, polyurethane primer and finish coats, and a white heat-reflective coating meeting Energy Star requirements. The design anticipates on-site foundation work, electrical connections, and plumbing installation by others, with specific requirements for anchor points, concrete slab preparation, and compliance with local building codes.

View the file

Other files

File Type Posted
ITB update Guard Shack - bid extension2.pdf PDF
PANG Guard Shack Bid Sheet001.pdf PDF
ATTACHMENT 7 Responsibility Inquiry~1.pdf PDF
PANG GUARD SHACK PREBID SIGN IN001~1.pdf PDF
Notice of Intent to Award guard shack-signed.pdf PDF
Notice To Proceed essex.pdf PDF
PANG Base G-11 Composite Utility Plan.pdf PDF
RFI Responses - Alert Shack Demo FINAL.pdf PDF
PANG Guard Shack ECP Project C-25-003 SIGNED.pdf PDF
G-11 Composite Utility Map.pdf PDF
RFI Responses - Alert Shack Demo - 5-19.pdf PDF
G-11 Composite Map D-size.pdf PDF
18-E1 - Electrical Site Plan.pdf PDF
ITB update Guard Shack - bid extension.pdf PDF
BLDG 215_FP01.pdf PDF
RFI Responses - Alert Shack Demo - updated.pdf PDF
Existing Guard Shack As-Builts.pdf PDF
RFI Responses - Alert Shack Demo FINAL.pdf PDF
Existing Guard Shack As-Builts.pdf PDF
BLDG 215_FP01.pdf PDF
G-11 Composite Map D-size.pdf PDF
ITB update Guard Shack - bid extension.pdf PDF
PANG Base G-11 Composite Utility Plan.pdf PDF
ITB update Guard Shack.pdf PDF
18-E1 - Electrical Site Plan.pdf PDF
RFI Responses - Alert Shack Demo - updated.pdf PDF
G-11 Composite Utility Map.pdf PDF
PANG GUARD SHACK PREBID SIGN IN001~1.pdf PDF
ITB update Guard Shack~1.pdf PDF
Drawings for new ECP.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PO

R

TL

A N D

A

IR

N A

TI

O N A L

G U A R D

G U A R D

B O

O

TH

JO

B

N o:

BY

: R G

D

AT

E:

-1 3-

SC

AL

E:

A S

N O

TE

D

SH

EE

T 1 O F

12DELUXE GUARD BOOTH STYLE

MANUFACTURED FOR :

PORTLAND AIR NATIONAL GUARD

GUARD BOOTH

142nd CIVIL ENGINEERING

6801 NE CORNFOOT RD.

PORTLAND, OR 97218

BY: B.I.G. ENTERPRISES

9702 E. RUSH ST

SOUTH EL MONTE CA 91733

SUBMITTAL DRAWINGS FOR APPROVAL

APPROVED DRAWINGS MUST BE RETURNED

APPROVED AS IS

APPROVED AS NOTED

REVISE AND RESUBMIT

BEFORE PRODUCTION CAN BEGIN

SIGNATURE DATE

SIGNATURE

SIGNATURE DATE

DATE

GENERAL INFO

8'-0" x 17'-0" x 9'-8" TALL

SINGLE STORY

136.00 SQ. FT.

ONE (1) UNIT

B.

I.G

. E N

TE

R

PR

IS

ES

, I

N C

E

. R U

SH

S

TR

EE

T

SO

U

TH

E L

M O

N

TE

, C A

3-

(6

) 4

-1

B.I.G. ENTERPRISES ™

THESE PLANS, DRAWINGS, AND/OR CADD FILES ARE THE COPYRIGHTED WORK OF B.I.G.

ENTERPRISES AND IS A TRADEMARK OF B.I.G. ENTERPRISES. COPYING OR UNAUTHORIZED

USE OF THESE DESIGNS OR ITS LIKENESS WILL BE PROSECUTED TO THE MAXIMUM EXTENT

PERMITTED UNDER APPLICABLE STATE AND FEDERAL LAW. ©

B.I.G. ENTERPRISES 1988 ALL RIGHTS RESERVED

FOUNDATION

THE FOUNDATION WORK IS TO BE DESIGNED AND INSTALLED BY

OTHERS IN ACCORDANCE WITH LOCAL CODES AND SOIL

CONDITIONS.

Sheet Index Description Sheet

Number

COVER PAGE 1

E1 ELEVATION 2

E2 & E4 ELEVATIONS 3

E3 ELEVATION 4

FLOOR PLAN 5

STUB UP AREA & ANCHOR PLAN 6

ELECTRICAL NOTES 7

ELECTRICAL PLAN 8

INTERIOR ELEVATION 9

RESTROOM ELEVATION 10

PLUMBING INFORMATION 11

GENERAL NOTES 12

BASIC DESIGN CRITERIA

OCCUPANCY GROUP: B

CONSTRUCTION CLASSIFICATION: V-B

RISK CATEGORY: II

WIND LOAD: Vult = 115 MPH

Vasd = 90 MPH Exposure C

FLOOR LOAD: 60 PSF

ROOF LIVE LOAD: 25 PSF

ROOF DEAD LOAD: 5 PSF

GROUND SNOW LOAD: 11 PSF

3" 22" 2"

45" 2"

3"

SLOPED 1/4" PER 12"

21"

41"

40"

3"

7" 6"

REAR

8"17

8"

2"

9'-8" [116"] O.A.

SHIPPING

HEIGHT

18'-13 4" [2173

4"] O.A. SHIPPING LENGTH

17'-0" [204"] NOMINAL SIZE - TYP

17'-33 4" [2073

4"] INCLUDES 1/4" ARMOR PLATE & 1 58" CONT. INSULATION PANELS - TYP

3" 38"

2" 39"45"

ALL

STEEL

WALL

REMOVABLE LIFTING EYE

(QTY: 6)

2"

OVERLAP

TYP

7'-6" [90"]

CEILING

HEIGHT

A.F.G.

EXHAUST FAN HOOD

Ø3" ROOF JACK VENT

3" x 3" x .120"

LIFTING EYE TUBE - TYP

ALL

STEEL

WALL

PO

R

TL

A N D

A

IR

N A

TI

O N A L

G U A R D

G U A R D

B O

O

TH

JO

B

N o:

BY

: R G

D

AT

E:

-1 3-

SC

AL

E:

A S

N O

TE

D

B.

I.G

. E N

TE

R

PR

IS

ES

, I

N C

E

. R U

SH

S

TR

EE

T

SO

U

TH

E L

M O

N

TE

, C A

3-

(6

) 4

-1

B.I.G. ENTERPRISES ™

THESE PLANS, DRAWINGS, AND/OR CADD FILES ARE THE COPYRIGHTED WORK OF B.I.G.

ENTERPRISES AND IS A TRADEMARK OF B.I.G. ENTERPRISES. COPYING OR UNAUTHORIZED

USE OF THESE DESIGNS OR ITS LIKENESS WILL BE PROSECUTED TO THE MAXIMUM EXTENT

PERMITTED UNDER APPLICABLE STATE AND FEDERAL LAW. ©

B.I.G. ENTERPRISES 1988 ALL RIGHTS RESERVED

SH

EE

T 2 O F

E1 LEFT ELEVATION

SCALE: 1/2" = 1'-0"

2"3" 3"

8"

3" 6"361 2"6"

OVERFLOW SCUPPER

(QTY: 2)

2"

9'-13 8" [1093

8"] O.A. ASSEMBLY WIDTH

8'-93 4" [1053

4"] SHIPPING WIDTH

8'-0" [96"]

8'-33 4" [993

4"]

8"

3"

LIFTING RINGS ~ 7'-9" [93"] C.C.63

8" 63

8"

8" 8'-0" [96"]

8'-33 4" [993

4"]

8"

ALL

STEEL

WALL

FABRIC ROLL DOWN SHADES

15"

47"

2"

3" O.H. TYP

3"

34"

2"

OVERLAP

TYP

9'-8" [116"] O.A.

SHIPPING

HEIGHT

2"

DISCONNECT SWITCH

6" W x 9 12" H x 3" D

16 GA HVAC CHASEWAY

GFCI RECEPTACLE

w/ IN-USE COVER

EXTERIOR A/C UNIT TO

SHIP LOOSE FOR ON SITE

INSTALLATION BY OTHERS.

(SHOWN FOR REFERENCE)

DOWNSPOUT

(QTY: 2)

PO

R

TL

A N D

A

IR

N A

TI

O N A L

G U A R D

G U A R D

B O

O

TH

JO

B

N o:

BY

: R G

D

AT

E:

-1 3-

SC

AL

E:

A S

N O

TE

D

B.

I.G

. E N

TE

R

PR

IS

ES

, I

N C

E

. R U

SH

S

TR

EE

T

SO

U

TH

E L

M O

N

TE

, C A

3-

(6

) 4

-1

B.I.G. ENTERPRISES ™

THESE PLANS, DRAWINGS, AND/OR CADD FILES ARE THE COPYRIGHTED WORK OF B.I.G.

ENTERPRISES AND IS A TRADEMARK OF B.I.G. ENTERPRISES. COPYING OR UNAUTHORIZED

USE OF THESE DESIGNS OR ITS LIKENESS WILL BE PROSECUTED TO THE MAXIMUM EXTENT

PERMITTED UNDER APPLICABLE STATE AND FEDERAL LAW. ©

B.I.G. ENTERPRISES 1988 ALL RIGHTS RESERVED

SH

EE

T 3 O F

E2 FRONT ELEVATION

SCALE: 1/2" = 1'-0" E4 REAR ELEVATION

SCALE: 1/2" = 1'-0"

LED WALL PACK

(SHIPS LOOSE)

3"22" 2"3"

38" 2"

39"3" 20"

LIFTING RINGS ~ 8'-11

2" [971

2"] C.C.93

8" LIFTING RINGS ~ 8'-71

2" [1031 2"] C.C. 63

8"

36" 2"

32"

8"17

8" 17'-0" [204"] NOMINAL SIZE - TYP

6'-8" [80]

2"

6"

REAR

17'-33 4" [2073

4"] INCLUDES 1/4" ARMOR PLATE & 1 58" CONT. INSULATION PANELS - TYP

7'-6" [90"]

CEILING

HEIGHT

A.F.G.

ALL

STEEL

WALL

ALL

STEEL

WALL

9'-8" [116"] O.A.

SHIPPING

HEIGHT

SLOPED 1/4" PER 12"

2"

OVERLAP

TYP

DOWNSPOUT

(QTY: 2)

SEAMLINE - TYP

PO

R

TL

A N D

A

IR

N A

TI

O N A L

G U A R D

G U A R D

B O

O

TH

JO

B

N o:

BY

: R G

D

AT

E:

-1 3-

SC

AL

E:

A S

N O

TE

D

B.

I.G

. E N

TE

R

PR

IS

ES

, I

N C

E

. R U

SH

S

TR

EE

T

SO

U

TH

E L

M O

N

TE

, C A

3-

(6

) 4

-1

B.I.G. ENTERPRISES ™

THESE PLANS, DRAWINGS, AND/OR CADD FILES ARE THE COPYRIGHTED WORK OF B.I.G.

ENTERPRISES AND IS A TRADEMARK OF B.I.G. ENTERPRISES. COPYING OR UNAUTHORIZED

USE OF THESE DESIGNS OR ITS LIKENESS WILL BE PROSECUTED TO THE MAXIMUM EXTENT

PERMITTED UNDER APPLICABLE STATE AND FEDERAL LAW. ©

B.I.G. ENTERPRISES 1988 ALL RIGHTS RESERVED

SH

EE

T 4 O F

E3 RIGHT ELEVATION

SCALE: 1/2" = 1'-0"

AutoCAD SHX Text 8'-1 " [97 "] C.C.

AutoCAD SHX Text 8'-7 " [103 "] C.C.

ALL RESTROOM EQUIPMENT TO BE SHIPPED LOOSE FOR

INSTALLATION ON SITE BY OTHERS. B.I.G. TO PROVIDE

BRACING HARD POINTS FOR SINK AND ANY REQUESTED

GRAB BARS. ANY OTHER BRACING POINTS OR CUTOUTS

REQUIRED MUST BE SPECIFIED PRIOR TO B.I. G.

PRODUCTION RELEASE.

NOTE:

OS

GUARD AREA

RESTROOM

J

GFCI

(WP)

SINK AREA

PONY WALL FOR SINK

PLUMBING AREA

w/ WINDOW SILL

26"

CLEAR

W GFCIOSD

J

USB

USB

SHELF

34" A.F.F.

SHELF 36" A.F.F.

GFCI GFCI

GFCI

GFCI

16 15 17

SHELF

36" A.F.F.

2 4

PO

R

TL

A N D

A

IR

N A

TI

O N A L

G U A R D

G U A R D

B O

O

TH

JO

B

N o:

BY

: R G

D

AT

E:

-1 3-

SC

AL

E:

A S

N O

TE

D

FLOOR PLAN LEGEND:

36" x 80" SLIDING DOOR - GENERAL NOTE D1

22" DEEP SHELF - GENERAL NOTE A1

Ø3" CORD ACCESS HOLE

36" x 80" RR SLIDING DOOR - GENERAL NOTE RR1

EXHAUST FAN - GENERAL NOTE M2

Ø3" ROOF VENT (TOILET) - GENERAL NOTE RR1

DOWNSPOUT - GENERAL NOTE R1

OVERHANG - GENERAL NOTE R1

ANCHOR CLIP - GENERAL NOTE S5

20" DEEP "L" SHAPED SHELF - GENERAL NOTE A1(a)

ARMOR PLATE - GENERAL NOTE S1

CONT. INSULATION - GENERAL NOTE S3

HVAC CONDENSER UNIT - MECHANICAL NOTE M1

HVAC CASSETTE UNIT - MECHANICAL NOTE M1

HVAC CHASE WAY - MECHANICAL NOTE M1(a)

LOAD CENTER - ELECTRICAL NOTE E1

ELECTRICAL CABINET - ELECTRICAL NOTE E1

HVAC 12" x 12" SUPPLY GRILLE - MECHANICAL NOTE M1(a)

Ø1 12" ROOF VENT (SINK) - GENERAL NOTE RR1

TOILET - GENERAL NOTE RR3

SINK S.S. (5" DEEP BASIN) - GENERAL NOTE RR3

22 ROLL DOWN SHADES - GENERAL NOTE W1(a)

ELECTRICAL NOTES & PLAN ON SHEET 7 & 8

B.

I.G

. E N

TE

R

PR

IS

ES

, I

N C

E

. R U

SH

S

TR

EE

T

SO

U

TH

E L

M O

N

TE

, C A

3-

(6

) 4

-1

B.I.G. ENTERPRISES ™

THESE PLANS, DRAWINGS, AND/OR CADD FILES ARE THE COPYRIGHTED WORK OF B.I.G.

ENTERPRISES AND IS A TRADEMARK OF B.I.G. ENTERPRISES. COPYING OR UNAUTHORIZED

USE OF THESE DESIGNS OR ITS LIKENESS WILL BE PROSECUTED TO THE MAXIMUM EXTENT

PERMITTED UNDER APPLICABLE STATE AND FEDERAL LAW. ©

B.I.G. ENTERPRISES 1988 ALL RIGHTS RESERVED

SH

EE

T 5 O F

FLOOR PLAN

SCALE: 1/2" = 1'-0"

E1

E2

E4

E3

E9

E810

E5 9

E710

E6

TL

A N D

A

IR

N A

TI

O N A L

G U A R D

G U A R D

B O

O

TH

JO

B

N o:

BY

: R G

D

AT

E:

-1 3-

SC

AL

E:

A S

N O

TE

D

74"116"

8"

8"

88"

8"

5"

4" TYP

3"

12"

12"

17'-33 4" [2073

4"] INCLUDES 1/4" ARMOR PLATE, 1 58" CONT. INSULATION PANELS - TYP

17'-0" [204"] NOMINAL SIZE - TYP

8"

GUARD AREA

RESTROOM

1" TYP

6"

8'-0" [96"]

8'-33 4"

[993 4"]

SINK AREA

2"

3"

2"

8"

8"

194"

8"

FULL HEIGHT PLUMBING WALL

STUB UP AREA

WASTE STUB UP AREA

℄ OF ANCHORS - TYP

2" x 3" x 1/4" ANCHOR CLIP.

TYP AT EACH CORNER. COVER

PLATES PROVIDED IN THE FLOOR

DECK FOR ACCESS DURING

INSTALLATION

ELECTRICAL STUB UP AREA

PONY WALL FOR PLUMBING STUB UP

SINK AREA w/ WINDOW SILL ABOVE

8"

8"

8"

3" TYP

21"

8"

8"

21"47 8"

8"

Ø 34" HOLE - TYP

B.

I.G

. E N

TE

R

PR

IS

ES

, I

N C

E

. R U

SH

S

TR

EE

T

SO

U

TH

E L

M O

N

TE

, C A

3-

(6

) 4

-1

B.I.G. ENTERPRISES ™

THESE PLANS, DRAWINGS, AND/OR CADD FILES ARE THE COPYRIGHTED WORK OF B.I.G.

ENTERPRISES AND IS A TRADEMARK OF B.I.G. ENTERPRISES. COPYING OR UNAUTHORIZED

USE OF THESE DESIGNS OR ITS LIKENESS WILL BE PROSECUTED TO THE MAXIMUM EXTENT

PERMITTED UNDER APPLICABLE STATE AND FEDERAL LAW. ©

B.I.G. ENTERPRISES 1988 ALL RIGHTS RESERVED

SH

EE

T 6 O F

INDICATES STUB AREA

STUB UP AREA / ANCHOR PLAN

SCALE: 1/2" = 1'-0"

E1

E2

E4

E3

JO

B

N o:

BY

: R G

D

AT

E:

-1 3-

SC

AL

E:

A S

N O

TE

D

PO

R

TL

A N D

A

IR

N A

TI

O N A L

G U A R D

G U A R D

B O

O

TH

B.

I.G

. E N

TE

R

PR

IS

ES

, I

N C

E

. R U

SH

S

TR

EE

T

SO

U

TH

E L

M O

N

TE

, C A

3-

(6

) 4

-1

B.I.G. ENTERPRISES ™

THESE PLANS, DRAWINGS, AND/OR CADD FILES ARE THE COPYRIGHTED WORK OF B.I.G.

ENTERPRISES AND IS A TRADEMARK OF B.I.G. ENTERPRISES. COPYING OR UNAUTHORIZED

USE OF THESE DESIGNS OR ITS LIKENESS WILL BE PROSECUTED TO THE MAXIMUM EXTENT

PERMITTED UNDER APPLICABLE STATE AND FEDERAL LAW. ©

B.I.G. ENTERPRISES 1988 ALL RIGHTS RESERVED

SH

EE

T 7 O F

ELECTRICAL NOTES:

E1. UNIT TO HAVE ONE 3 WIRE SINGLE PHASE, 12 POLE, 125 AMP RATED, 120/240 VOLT LOAD CENTER (SUBJECT TO

AVAILABILITY) FLUSH MOUNTED IN AN ELECTRICAL CABINET ON THE FRONT WALL OVER TO THE RIGHT.

E2. ALL ELECTRICAL EQUIPMENT TO BE U.L. LISTED AND ALL WIRING TO BE PER CURRENT PUBLISHED NEC STANDARDS. ALL CONDUCTORS TO BE COPPER, WITH A MINIMUM SIZE OF THHN #12 SOLID COPPER. EXPOSED WIRING TO BE IN SURFACE MOUNTED EMT CONDUIT. CONCEALED WIRING TO BE IN FLEXIBLE ALUMINUM CONDUIT. FINAL POWER CONNECTION AND GROUNDING TO BE DONE ON SITE BY OTHERS. ALL WORK TO BE DONE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE

WITH ALL APPLICABLE LOCAL CODES.

A. ALL CIRCUITS TO BE GROUNDED.

B. ALL STEEL EQUIPMENT AND EXPOSED STRUCTURAL STEEL TO BE BONDED TO ELECTRICAL SYSTEM.

E3. UNIT TO HAVE (2) DUPLEX RECEPTACLES w/ USB CHARGER AND (1) DUPLEX RECEPTACLE UNDER THE FRONT SHELF.

E4. UNIT TO HAVE (4) GFCI DUPLEX RCPT UNDER THE "L" SHAPED SHELF, TWO UNDER EACH SECTION AS SHOWN.

A. UNIT TO HAVE (1) GFCI DUPLEX RCPT IN THE SINK AREA ON THE RIGHT WALL.

E5. UNIT TO HAVE (2) DOUBLE GANG J-BOXES UNDER THE FRONT SHELF, EACH w/Ø3/4" CONDUIT RUN TO THE STUB UP AREA.

A. UNIT TO HAVE (1) JUNCTION BOX MOUNTED IN THE SINK AREA ON THE RIGHT WALL. J-BOX IS TO BE WIRED FOR 240V, AND IS PROVIDED FOR THE ELECTRICAL CONNECTION OF THE WATER HEATER. THE WATER HEATER IS SHIPPED LOOSE

AND IS TO BE INSTALLED AS PART OF THE OVERALL PLUMBING INSTALLATION, BY OTHERS.

E6. ALL EMPTY JUNCTION BOXES TO HAVE PULL STRINGS UNLESS NOTED OTHERWISE.

E7. ITEMS OF A SIMILAR NATURE SHALL BE OF THE SAME TYPE AND MANUFACTURE.

E8. ALL HEIGHT CALLOUTS TO BE MEASURED TO TOP OF RECEPTACLE/JUNCTION BOXES, UNLESS NOTED OTHERWISE.

E9. ALL DETAILS, SECTIONS, AND NOTES SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO SIMILAR SITUATIONS ELSEWHERE, UNLESS NOTED OTHERWISE. NOTES AND DETAILS ON THE DRAWINGS TAKE

PRECEDENCE OVER THE GENERAL NOTES AND TYPICAL DETAILS.

MECHANICAL NOTES:

M1. THE GUARD AREA IS TO BE SERVICED BY A DUCTLESS CEILING CASSETTE SPLIT SYSTEM. HVAC UNIT TO BE A

MITSUBISHI MODEL PUZ-A24NHA7 (CONDENSER UNIT) AND PLA-A24EA7 (CEILING CASSETTE UNIT) (OR EQUAL).

B. HVAC INTERIOR CASSETTE UNIT, Ø4" INSULATED BRANCH DUCT TO A 12" x 12" SUPPLY GRILLE TO THE RESTROOM, REFRIGERANT LINES, AND ELECTRICAL TO SHIP FULLY INSTALLED IN A CHASE OUT THE REAR. CHASE TO BE 16 GA

GALVANIZED STEEL PAINTED TO MATCH THE GUARDHOUSE EXTERIOR.

C. CONDENSATE DRAIN LINE TO TERMINATE IN THE PLUMBING WALL.

D. HVAC EXTERIOR CONDENSER UNIT WILL SHIP LOOSE. FINAL INSTALLATION OF THE HVAC SYSTEM INCLUDING:

CONNECTION OF REFRIGERANT LINES TO THE INTERIOR AND EXTERIOR UNITS, EVACUATING & CHARGING, THE INSTALLATION, CONNECTION, & PROGRAMMING THE THERMOSTAT, AND DIAGNOSTICS TEST MUST BE DONE ON SITE.

INSTALLATION AND MAINTENANCE OF THE ENTIRE SYSTEM MUST BE PERFORMED BY A CERTIFIED HVAC CONTRACTOR

IN ORDER TO MAINTAIN WARRANTY COVERAGE.

E. D. HVAC EXTERIOR UNIT WILL INCLUDE A NON-FUSED 60A DISCONNECT SWITCH & (1) EXTERIOR GFCI RECEPTACLE w/ IN-USE COVER FOR SERVICING.

M2. UNIT TO INCLUDE A BROAN BRO-A80 (80 CFM) EXHAUST FAN w/ BROAN 636 ROOF CAP (OR EQUAL) IN THE RESTROOM.

PANEL SCHEDULE

PANEL NAME: VOLTS: 120 / 240V MAIN TYPE: MAIN LUG

MOUNTING: FLUSH WIRES: THREE BUS RATING: 125A

ENCLOSURE: NEMA 1 PHASE: SINGLE MAIN BREAKER RATING: N/A

CKT DESCRIPTION C.B.

AMPS

C.B.

POLES A B C.B.

POLES

C.B.

AMPS DESCRIPTION CKT

HVAC UNIT 25A 2

1200 86 1 20A (1) INT LIGHT, (1) CAN, (1) WALL PK 2

3 1200 540 1 20A (2) DUPLEX RCPT w/USB, (1) DUPLEX 4

WATER HEATER 20A 2

1750 360 1 20A (2) GFCI DUPLEX RCPT 6

7 1750 360 1 20A (2) GFCI DUPLEX RCPT 8

9 360 1 20A (1) GFCI RCPT, (1) GFCI EXT. SERVICE 10

11 12

TOTAL A LEG 3756 3850 TOTAL B LEG

TOTAL WATTS 7606

TOTAL x 125% 9507.5

WATTS / 240V 39.6 AMPS

OS

GUARD AREA

RESTROOM4

J

(WP)

GFCI

P

SINK AREA

W GFCIOSD

J

USB

USB

GFCI GFCI

GFCI

GFCI

Ø 34" TO

STUB UP

AREA

TO

CEILING

CASSETTE

1 & 3

5 & 7

LOAD CENTER

w/ELEC. CAB.

JO

B

N o:

BY

: R G

D

AT

E:

-1 3-

SC

AL

E:

A S

N O

TE

D

PO

R

TL

A N D

A

IR

N A

TI

O N A L

G U A R D

G U A R D

B O

O

TH

B.

I.G

. E N

TE

R

PR

IS

ES

, I

N C

E

. R U

SH

S

TR

EE

T

SO

U

TH

E L

M O

N

TE

, C A

3-

(6

) 4

-1

B.I.G. ENTERPRISES ™

THESE PLANS, DRAWINGS, AND/OR CADD FILES ARE THE COPYRIGHTED WORK OF B.I.G.

ENTERPRISES AND IS A TRADEMARK OF B.I.G. ENTERPRISES. COPYING OR UNAUTHORIZED

USE OF THESE DESIGNS OR ITS LIKENESS WILL BE PROSECUTED TO THE MAXIMUM EXTENT

PERMITTED UNDER APPLICABLE STATE AND FEDERAL LAW. ©

B.I.G. ENTERPRISES 1988 ALL RIGHTS RESERVED

SH

EE

T 8 O F

ELECTRICAL PLAN

SCALE: 1/2" = 1'-0"

E1

NOTE:

1. ALL WIRING TO BE A MINIMUM OF THHN #12 SOLID

COPPER.

2. ALL CIRCUITS TO BE GROUNDED.

3. ALL STEEL EQUIPMENT AND EXPOSED STRUCTURAL

STEEL TO BE BONDED TO ELECTRICAL SYSTEM.

OSOS

GFCIGFCI

125V GFCI DUPLEX OUTLET

WATER HEATER J-BOX

THERMOSTAT

OCCUPANCY SENSOR SWITCH

(MANUAL ON / AUTO OFF)

GFCI

(WP)(WP)

GFCI 125V GFCI DUPLEX RCPT.

w/ WEATHERPROOF IN-USE COVER

60A DISCONNECT SWITCH, UN-FUSED

SWITCH LEG

LOAD CENTER

CONDUIT HOMERUN TO PANEL;

CIRCUIT NUMBER;#

NUMBER DENOTES BOX HEIGHT. ALL TO BE

20" A.F.F. UNLESS OTHERWISE NOTED

POWER CONDUIT, ALL TO BE MIN. Ø1

2"

UNLESS NOTED OTHERWISE

DATA CONDUITS, ALL TO BE MIN. Ø 12"

UNLESS NOTED OTHERWISE

Ø 34"

WW

LIGHTING SCHEDULE

MODEL NO.MANUFACTURERDESCRIPTION NOTESTYPE QTYITEM

MAXLITE MLFP14G420WCS 20 W 3 OCCUPANCY SENSOR / DIMMERLED LIGHT FIXTURE1

MODEL NO.MANUFACTURER CEER / HSPF

RATING

21.4 /11.0

BTU/h

COOL

24,000

HEAT

26,000

MECHANICAL EQUIPMENT SCHEDULE

PUZ-A24NHA7MITSUBISHI

NOTES

CONDENSER

DESCRIPTIONITEM

PLA-A24EA7MITSUBISHICEILING CASSETTE

BROA80BROANEXHAUST FAN 80 CFM / RESTROOM

A

B

C

HALO HLB6099FS1EMWR 14 W 1LED CAN LIGHT

GUARD AREA

ELECTRICAL LEGEND

OSDOSD OCCUPANCY SENSOR /DIMMER SWITCH

(MANUAL ON / AUTO OFF)

EXTERIOR

OCCUPANCY SENSOR

BUILT-IN PHOTOCELL / SINGLE SWITCH3 LUMARK XTOR1B-PC1 LED 120V 12 W 1LED WALL PACK

USBUSB

125V DUPLEX RCPT. w/USB CHARGER

A

B

C

TL

A N D

A

IR

N A

TI

O N A L

G U A R D

G U A R D

B O

O

TH

JO

B

N o:

BY

: R G

D

AT

E:

-1 3-

SC

AL

E:

A S

N O

TE

D

22"

3" 3"16"

LOAD

CENTER

~4" DEEP

22"

21" STUB

UP AREA

ELECTRICAL CABINET

w/ LOAD CENTER

SHELF

34"

A.F.F.

S.S. SHELF

24"

DUPLEX RCPT

w/USB CHARGER

(QTY: 2)

7'-6" [90"]

COVE MODING

12 POLE LOAD CENTERDOUBLE GANG J-BOX - TYPS.S. SHELFCEILING

HEIGHT

7'-6" [90"] A.F.F.

DUPLEX RCPT

SHELF SUPPORT

B.

I.G

. E N

TE

R

PR

IS

ES

, I

N C

E

. R U

SH

S

TR

EE

T

SO

U

TH

E L

M O

N

TE

, C A

3-

(6

) 4

-1

B.I.G. ENTERPRISES ™

THESE PLANS, DRAWINGS, AND/OR CADD FILES ARE THE COPYRIGHTED WORK OF B.I.G.

ENTERPRISES AND IS A TRADEMARK OF B.I.G. ENTERPRISES. COPYING OR UNAUTHORIZED

USE OF THESE DESIGNS OR ITS LIKENESS WILL BE PROSECUTED TO THE MAXIMUM EXTENT

PERMITTED UNDER APPLICABLE STATE AND FEDERAL LAW. ©

B.I.G. ENTERPRISES 1988 ALL RIGHTS RESERVED

SH

EE

T 9 O F

E5 INT. FRONT WALL ELEVATION

SCALE: 1/2" = 1'-0" AA SECTION

SCALE: 1/2" = 1'-0"

AA

1 4

3 6

5 8

ALL RESTROOM EQUIPMENT TO BE SHIPPED LOOSE FOR

INSTALLATION ON SITE BY OTHERS. B.I.G. TO PROVIDE

BRACING HARD POINTS FOR SINK AND ANY REQUESTED

GRAB BARS. ANY OTHER BRACING POINTS OR CUTOUTS

REQUIRED MUST BE SPECIFIED PRIOR TO B.I. G.

PRODUCTION RELEASE.

NOTE:

MODELNUMBERTRADENAMEPRODUCTMATERIAL

32" A.F.F.

~151 8"

3'-61 2" [421

2"]

32" A.F.F.

42" A.F.F.

18"

6'-2" [74"]

C

WATER SUPPLY AND DRAIN PIPES SHALL BE

INSULATED OR OTHERWISE CONFIGURED

TO PROTECT AGAINST CONTACT.

WORK TO BE PERFORMED ON SITE WHEN

PLUMBING SYSTEM IS CONNECTED.

18" x 24" MIRROR

PAPER TOWEL DISPENSER

TOILET PAPER HOLDER

WATER HEATERS.S. SINK w/5" DEEP BASIN

GFCI RECEPTACLE

WATER HEATER JUNCTION BOX

L

CEILING

HEIGHT

7'-6" [90"] A.F.F.

4"

FABRIC ROLL

DOWN SHADES

2"

3"

GFCI RECEPTACLE

CL

4'-11 2" [491

2"]

9 COAT HOOK

~27" A.F.F.

FULL HEIGHT PLUMBING

WALL FOR RESTROOM

PONY WALL

FOR SINK

PLUMBING

AREA

4" DEEP WINDOW

SILL ABOVE

PLUMBING WALL

4" DEEP PLUMBING

WALL - TYP

PONY WALL w/

REMOVABLE PANELS

SILL

47"

A.F.F.

MATERIAL

FULL HEIGHT PLUMBING WALL

w/ REMOVABLE PANELS

1" 4" PLUMBING

WALL

1"

MODELNUMBERTRADENAMEPRODUCTMATERIAL

3" 3" PO

R

TL

A N D

A

IR

N A

TI

O N A L

G U A R D

G U A R D

B O

O

TH

JO

B

N o:

BY

: R G

D

AT

E:

-1 3-

SC

AL

E:

A S

N O

TE

D

B.

I.G

. E N

TE

R

PR

IS

ES

, I

N C

E

. R U

SH

S

TR

EE

T

SO

U

TH

E L

M O

N

TE

, C A

3-

(6

) 4

-1

B.I.G. ENTERPRISES ™

THESE PLANS, DRAWINGS, AND/OR CADD FILES ARE THE COPYRIGHTED WORK OF B.I.G.

ENTERPRISES AND IS A TRADEMARK OF B.I.G. ENTERPRISES. COPYING OR UNAUTHORIZED

USE OF THESE DESIGNS OR ITS LIKENESS WILL BE PROSECUTED TO THE MAXIMUM EXTENT

PERMITTED UNDER APPLICABLE STATE AND FEDERAL LAW. ©

B.I.G. ENTERPRISES 1988 ALL RIGHTS RESERVED

SH

EE

T 10 O

F

E6 ELEVATION

SCALE: 1/2" = 1' - 0" E8 ELEVATION

SCALE: 1/2" = 1' - 0" BB LAV CLEARANCES

SCALE: 1/2" = 1' - 0"E7 ELEVATION

SCALE: 1/2" = 1' - 0"

BB

E9 ELEVATION

SCALE: 1/2" = 1' - 0"

TL

A N D

A

IR

N A

TI

O N A L

G U A R D

G U A R D

B O

O

TH

JO

B

N o:

BY

: R G

D

AT

E:

-1 3-

SC

AL

E:

A S

N O

TE

D

SEE APPROVED SHOP DRAWINGS

FOR STUB UP LOCATIONS

DWV PIPING MUST BE INSTALLED IN SLAB

NO BELOW FLOOR ACCESS

TYPICAL DWV & SUPPLY

PIPING ARE STUBBED UP BEHIND

REMOVABLE WALL PANELS

NOTE:

THIS DRAWING IS MEANT TO SHOW THE TYPE OF

PLUMBING WORK REQUIRED TO CONNECT THE GUARD HOUSE.

ACTUALL PLANS, PERMITS AND INSTALLATION ARE BY

OTHERS.

REMOVABLE WALL PANELS

(SHOWN FOR REFERENCE)

NON-REMOVABLE

FIXTURE MOUNTING

POINT

TYPICAL DWV & SUPPLY

PIPING SUPPLIED AND

INSTALLED BY OTHERS

TYP WET VENT

MATERIALPRODUCTTRADENAMEMODELNUMBER

28"

10"

ALL FIXTURES SHIP LOOSE

FOR INSTALLATION ON SITE BY OTHERS

REMOVABLE

WALL PANEL

FULL HEIGHT

PLUMBING

WALL

CONCRETE SLAB TO ACT AS THE RESTROOM FLOOR.

CONCRETE TO BE SMOOTH, HARD AND NONABSORBENT.

RESTROOM WALLS ARE PAINTED GALVANIZED

STEEL THAT IS SMOOTH, HARD AND

NONABSORBENT FROM THE FLOOR TO CEILING.

MODELNUMBERTRADENAMEPRODUCTMATERIALMODELNUMBERTRADENAMEPRODUCTMATERIALMODELNUMBERTRADENAMEPRODUCTMATERIALMATERIALPRODUCTTRADENAMEMODELNUMBER

RESTROOM WALL TYP

HARD POINTS

TYP BRANCH VENT

PONY WALL FOR SINK AREA

GLAZING ABOVE SINK AREA NOTE:

REMOVABLE WALL PANELS SHOWN ARE

BASED ON TYPICAL INSTALLATION AND

ARE SHOWN FOR REFERENCE ONLY.

(FINAL SIZES AND LOCATION MAY VARY)

TYP VENT STACK

HVAC - Ø1" CONSENSATE DRAIN LINE

STACK VENT

3" VENT STACK

3"x3"x 1-1/2" SAN-T

SINK

3"x3"x3" SAN-T

SANITARY STACK DIAGRAM

(BY OTHERS ON SITE)

CLEANOUT

18"

3"

42" Max

1-1/2"

ALL MATERIAL

PVC DWV TYP

W.C.

1" Ø CONDENSATE

LINE ( IF REQ.)

WATER

HEATER

WATER RISER DIAGRAM

(BY OTHERS ON SITE)

LAV

1/2"

12" 3/4" x 3/4" x 1/2" T

3/4" INLET

W.C.

65"

3/4"

B.

I.G

. E N

TE

R

PR

IS

ES

, I

N C

E

. R U

SH

S

TR

EE

T

SO

U

TH

E L

M O

N

TE

, C A

3-

(6

) 4

-1

B.I.G. ENTERPRISES ™

THESE PLANS, DRAWINGS, AND/OR CADD FILES ARE THE COPYRIGHTED WORK OF B.I.G.

ENTERPRISES AND IS A TRADEMARK OF B.I.G. ENTERPRISES. COPYING OR UNAUTHORIZED

USE OF THESE DESIGNS OR ITS LIKENESS WILL BE PROSECUTED TO THE MAXIMUM EXTENT

PERMITTED UNDER APPLICABLE STATE AND FEDERAL LAW. ©

B.I.G. ENTERPRISES 1988 ALL RIGHTS RESERVED

SH

EE

T 11 O

F

TYPICAL PLUMBING INSTALLATION

SCALE: 1/2" = 1' - 0"

WATER CLOSET

LAVATORY

FIXTURE FLOW RATE

1.6 GPM

2.0 GPM

TOTAL FLOW RATE 3.6 GPM

INLET SIZES

QTY EXTENDED

1.6 GPM

2.0 GPM

EXTENDEDQTY

PLUMBING FIXTURE COUNT

6TOTAL DRAIN UNITS

DRAIN UNITSFIXTURE

LAVATORY

WATER CLOSET

1.5 1.0

2.5

WATER SUPPLY FIXTURE UNITS

WSFU MIN. BRANCH

PIPE SIZE

1/2" 1/2"

3/4"

1WATER CLOSET

LAVATORY 1

FIXTURE QTY

TOTAL

System will require a minimum pressure range of 40 to 49 psi with a maximum development length of 400 ft with a 34" dia. supply.

STRUCTURAL:

S1. Unit to meet Underwriters Laboratories UL752; Standard for Bullet-Resisting equipment, level 3 as defined in paragraph 4.5, revised 9/9/05. Protection against hand guns of super power, such as the .44 Magnum, and the like, with muzzle energy of 971-1175 foot-pounds. The bullet resistant protection does not include the floor frame, fascia, ceiling, or roof. Protection is based upon using .44 magnum lead semi-wadcutter gas checked ammunition, with 240 grain, and a velocity of 1,350-1,485 fps.

S2. Frame work to be 2" x 3" x .083", 3" x 3" x .083", 2" x 3" x .120" and 3" x 3" x .120" steel tube.

S3. Walls to have half glazed bullet resistant exterior and & 16 ga. interior liners. Walls to have R-13 insulation value plus a layer of continuous R-9.6 insulation encapsulated in an exterior 16 ga galvanized steel wall. Overall insulation value is R-22.6.

A. Walls to meet the threat level listed in note S1.

S4. Unit to have a 12 ga A653 galvanized steel floor covered with 1/4" thick x 20" square, black commercial polyvinyl chloride interlocking tiles with a 4" high black perimeter cove molding. Floor to be mounted on a 2" tall galvanized steel tube frame. Continuous insulation panels to overlap floor frame by 12".

A. Floor to have R-10 insulation.

CAUTION: Please contact your sales representative for additional information when planning on recessing the booth into the slab.

S5. Unit to have four interior anchor clips. Four 5/8" Hilti KH-EZ anchor screws (ICC-ESR-3027) with a 4" minimum embedment in 2500 psi concrete (or equal) are required for placement of booth (Anchor screws are not included). Concrete to be level.

If sloped, slope towards drain opening(s) on booth. Concrete and booth installation shall be by others. For a 4" embedment the foundation/slab design must be a minimum of 6" thick and be sized to allow for a minimum distance of 4" from the edge of the slab to the center line of the anchors for maximum strength.

ROOF:

R1. Unit to have a 21" Parapet fascia with 3" overhang on three sides and 6" overhang on the rear. Roof to have a16 ga galvanized steel roof sloped 14" per 12" to the rear, drained through two Ø1 12" PVC downspouts with overflow scuppers.

R2. Roof to have a R-19 insulation value.

R3. Unit to have (6) removable lifting eyes (Ø3/4" shank, eye is 1-1/2" I.D.) mounted on the roof. Lifting eyes are designed for a STRAIGHT VERTICAL LIFT ONLY. Spreader bars must be used when lifting booth to ensure this vertical lift. All warranties will be void if not lifted in this manner.

DOORS & WINDOWS:

D1. Unit to have one 36" x 80" bullet resistant steel framed slide door mounted on the right wall. Door to be top hung, in a steel track, on a minimum of eight 3" steel ball bearing rollers with stainless steel lower guide, mortise hook type lock and complete weather stripping.

A. Door to meet the threat level listed in note #1.

W1. Unit to have Clear bullet resistant glass clad polycarbonate glazing throughout.

A. Unit to have one window on the rear wall above the sink area with Insoroll manual roll down shade. Window to have a sill height of 47" above finished floor (A.F.F.)

B. Glazing to meet the threat level listed in note S1.

W2. Customer to specify the color of tint prior to B.I.G. production release.

Standard tint colors are Bronze or Gray.

A. If customer does not provide a tint selection, B.I.G. will choose a standard tint color that best complements the paint color selected.

ACCESSORIES:

A1. Unit to have a 22" deep shelf on the front wall with Ø3" electric access grommet inserts and mounted at 34" above finished floor (A.F.F.)

A. Unit to have a 20" deep "L" shaped shelf on the restroom partition wall with

Ø3" electric access grommet inserts and mounted at 36" above finished floor (A.F.F.)

B. Shelves to be 304 stainless steel with a #4 finish. The shelves to be rated for a 250 lb. load.

WEATHER PROOFING & FINISH:

F1. All exposed steel surfaces except roof deck to be coated with two component high solids polyurethane rust inhibitive primer, and two component high solids polyurethane finish coat.

F2. Unit to be painted one color inside and out.

A. Customer to provide color selection prior to manufacturing.

F3. Roof to be fully weather sealed with a three step elastomeric membrane as follows:

A. All seams are sealed with a gun applied one part polyurethane sealant.

B. The entire roof deck is then coated with a Class A rated liquid applied one-part polyurethane coating forming a tough waterproof, weather-resistant elastomeric coating.

C. The entire deck surface finished with a Class A rated white heat reflective polyurethane coating. The coating meets Energy Star reflectance and emissivity performance requirements, has an SRI of 95, and is approved by the Cool Roof Rating Council (CRRC).

RR1. Unit to have a restroom area with partition walls and open sink area, all steel 36" x 80" slide door with privacy lock, exhaust fixture (min 80 cfm, Broan BROA80 or equal) and one installed Ø3" roof jacks with Ø3" PVC tube vent stubbed 6" below ceiling. Verification of vent sizing, and vent installation to be by others in coordination with the local applicable codes.

RR2. All piping is to be supplied and installed on site by others.

RR3. The water closet shall not exceed 1.28 GPF. The lavatory flow rate shall not exceed 0.5 gpm at 60 psi. Total flow shall not exceed 0.25 gallons per activation.

RR3. The following equipment (or equals) will be shipped loose for on site installation by others:

· Lavatory: Gridmann GR13-SERV1 (NSF)

· Faucet set: Gridmann faucet GR13-SERV1

· Toilet: Kohler K-31621

· Toilet seat: PROFLO-PFTS20000WH

· TP holder: Bobrick S.S. B-6857

· Paper towel holder: Bobrick S.S. B-262

· Coat hook, double: Bobrick S.S. B-6727

· Soap dispenser: Bobrick S.S. B-2111

· Mirror: 18" x 24" Bobrick B1651 1824

· Water Heater: 240v 3.5KW EEMAX SPEX35

RESTROOM:

PO

R

TL

A N D

A

IR

N A

TI

O N A L

G U A R D

G U A R D

B O

O

TH

JO

B

N o:

BY

: R G

D

AT

E:

-1 3-

SC

AL

E:

A S

N O

TE

D

GENERAL NOTES:

B.

I.G

. E N

TE

R

PR

IS

ES

, I

N C

E

. R U

SH

S

TR

EE

T

SO

U

TH

E L

M O

N

TE

, C A

3-

(6

) 4

-1

B.I.G. ENTERPRISES ™

THESE PLANS, DRAWINGS, AND/OR CADD FILES ARE THE COPYRIGHTED WORK OF B.I.G.

ENTERPRISES AND IS A TRADEMARK OF B.I.G. ENTERPRISES. COPYING OR UNAUTHORIZED

USE OF THESE DESIGNS OR ITS LIKENESS WILL BE PROSECUTED TO THE MAXIMUM EXTENT

PERMITTED UNDER APPLICABLE STATE AND FEDERAL LAW. ©

B.I.G. ENTERPRISES 1988 ALL RIGHTS RESERVED

SH

EE

T 12 O

F

Sheets and Views
11647-1- CS
11647-2-ELEV
11647-3-ELEV
11647-4-ELEV
11647-5-FP
11647-6-STUB
11647-7-ELECT NOTES
11647-8-ELECT PLAN
11647-9-INT ELEV
11647-10-RR ELEV
11647-11-PLUMB
11647-12-GN

File details come from the government source that posted it. Updated .