Drawings - Electrical E1.1.pdf
PDF 2 MB Posted
- Solicitation number
- IFB1 IHKA 2017000258 4
- Issued by
- Garfield County, Colorado
About this file
This is an electrical construction drawing (E1.1) prepared by Boulder Associates, Inc. for the Resident Safety & Accessibility Improvements project at SVCLC at Rifle, located at 851 E. 5th Street, Rifle, Colorado 81650. The document represents 100% construction documents dated February 1, 2017, with revisions through April 25, 2017. The drawing details electrical work for a porte cochere installation, including bollard mounting specifications, branch circuit conduit and wiring, fixture schedules, and a reflective lighting plan. Key requirements include providing individual neutrals per National Electrical Code (NEC) standards, connecting exit and emergency egress luminaires to existing 120-volt emergency egress circuits, protecting fixtures during construction, and identifying junction boxes with panel and circuit numbers. The contractor is required to conduct a site survey prior to construction to verify existing conditions, as actual conditions may vary from documented panel directories and existing plans. The drawing indicates new work in solid bold lines, existing work in light lines, and removals with dashed lines, with circuit designations in parentheses indicating circuits being removed.
The document specifies that all drawings and specifications remain the property of Boulder Associates, Inc., and unauthorized reuse without written permission is prohibited, with the owner agreeing to indemnify the engineer from claims arising from such unauthorized use. The project involves both new electrical installations and the removal of abandoned cabling, conduits, and conductors to source. All conduits, cables, boxes, and luminaires must be supported per NEC 300.11 standards, with lay-in fixtures requiring support from two #12 AWG wires from opposite ends unless otherwise noted. Additionally, the contractor must update panelboard directories where circuits have been deleted or added, and photocell lighting controls are required for automatic dawn shut-off and dusk activation for both porte cochere and walkway lighting systems.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BOLLARD MOUNTING DETAIL
42"
12"
530_01
CONCRETE POLE BASE
FINISHED GRADE
NOT TO SCALE
BRANCH CIRCUIT CONDUIT AND
WIRE. RE: SITE PLAN
TYPICAL ANCHOR BOLT SET
TO BASE TEMPLATE
REFER TO FIXTURE
SCHEDULE FOR
HEIGHT
BOLLARD ANCHORAGE
SYSTEM
36"
P
S
S.4
7.6
7.3
X2
X1
Y1
Y2
S
Y1
Y2
X2
X1
7.6
F
F
G G G
G
G
GG
G
E6
E8
E
E
E7E7
R
9.2
8.7
9.1
Q
S
S.4
8.3
8.1
7.6
7.3
X1
Y1
Y2
Q
R
S
Y1
Y2
X1
7.6
8.1
8.3
8.7
9.2
GE
GE G
G G
G
LR1
E5
EL2-15
LP1A-35
OWNERSHIP OF DOCUMENTS:
ALL DRAWINGS, SPECIFICATIONS AND OTHER WORK PRODUCT OF THE ENGINEER FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE FOR THIS PROJECT ONLY AND SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE PROJECT IS COMPLETED OR NOT. REUSE OF ANY OF THE INSTRUMENTS OF SERVICE OF THE ENGINEER BY THE OWNER OF EXTENSIONS OF THIS PROJECT WITHOUT WRITTEN PERMISSION OF THE ENGINEER SHALL BE AT THE OWNER'S RISK AND THE OWNER AGREES TO DEFEND, INDEMNIFY AND HOLD HARMLESS THE ENGINEER FROM ALL CLAIMS, DAMAGES, AND EXPENSES INCLUDING ATTORNEYS' FEES ARISING OUT OF UNAUTHORIZED REUSE OF THE ENGINEER'S INSTRUMENTS OF SERVICE BY THE OWNER OR BY OTHERS ACTING THROUGH THE OWNER.
PROJECT NUMBER
DRAWN BY
DATE
REVISIONS
SHEET TITLE
SHEET NUMBER
Boulder Associates, Inc.
www.boulderassociates.com
Architecture + Interior Design
1426 Pearl Street, Suite 300
Boulder , Colorado 80302
303.499.7795
PROJECT
REV
T T
L B v .2
T H
IS
L
IN
E
I S
I N
C H
L O
N G
W H
E N
P R
IN
T
E D
T O
F U
L L S
C A
L E
ADDRESS
851 E. 5th STREET
RIFLE, CO 81650
/2
/2
:3 :2
P
M C
U s e rs
\r le d fo rd \D o c u m e n ts
\L o c a l R e v it F ile s \1
S V
N H a t R if le
E le c
R rl e d fo rd .r v t
152732.00
RSL
February 1, 2017
PORTE COCHERE -
ENLARGED PLANS
& DETAILS
E1.1
SVCLC AT RIFLE
RESIDENT
SAFETY &
ACCESSIBILITY
IMPROVEMENTS
100%
CONSTRUCTION
DOCUMENTS
0'2' 4' 10'
E2.2 3/16" = 1'-0"
FLOOR 2 - PORTE COCHERE REFLECTIVE LIGHTING PLAN3
0'2' 4' 10'
E1.0 3/16" = 1'-0"
ELECTRICAL SITE PLAN - PORTE COCHERE1
13. PROVIDE INDIVIDUAL NEUTRALS AS REQUIRED BY NEC ON ALL NEW AND EXISTING
CIRCUITS.
12. CONNECT ALL EXIT AND EMERGENCY EGRESS LUMINAIRES (DENOTED BY SHADING)
TO EXISTING 120-VOLT EMERGENCY EGRESS CIRCUIT SERVING THE AREA.
11. PROTECT FIXTURES THROUGHOUT CONSTRUCTION.
10. IDENTIFY JUNCTION BOXES WITH PANEL AND CIRCUIT NUMBER.
9. DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW EXACT LOCATIONS OF DEVICES
AND EQUIPMENT. REFER TO ARCHITECTURAL DRAWING FOR EXACT LOCATIONS.
8. SUPPORT ALL CONDUITS, CABLES, BOXES AND LUMINAIRES FROM STRUCTURE PER
NEC 300.11. LAY-IN FIXTURES SHALL BE SUPPORTED WITH TWO #12AWG WIRES FROM
OPPOSITE ENDS UNLESS NOTED OTHERWISE.
7. REMOVED ABANDONED CABLING TO SOURCE.
6. REMOVED ADANDONED CONDUITS AND CONDUCTORS TO SOURCE. DO NOT LEAVE
WIRES CONNECT TO SPARE BREAKERS.
5. EXISTING ELECTRICAL OUTLET, DEVICE, EQUIPMENT ITEM, LUMINAIRE, ETC., (SHOWN
AS DASHED) SHALL BE REMOVED TO THE NEAREST REMAINING OUTLET OR BRANCH
CIRCUIT OVER-CURRENT DEVICE. MAKE MODIFICATION TO EXISTING REMAINING...
4. CONTRACTOR TO VISIT THE JOB SITE TO SURVEY EXISTING CONDITIONS PRIOR TO
START OF CONSTRUCTION.
3. PANEL SCHEDULE INFORMATION AND EXISTING CIRCUITRY WAS TAKEN FROM
EXISTING PANEL DIRECTORIES AND PLANS. ACTUAL CONDITIONS MAY VARY. FIELD
VERIFY.
2. CONTRACTOR TO UPDATE PANELBOARD DIRECTORIES WHERE CIRCUITS HAVE BEEN
DELETED OR ADDED.
1. ALL NEW WORK IS SHOWN BY SOLID BOLD LINES; ALL EXISTING WORK IS SHOWN AS
LIGHT LINES. DASHED LINES INDICATES REMOVAL. (CIRCUIT DESIGNATIONS SHOWN
IN PARENTHESIS INDICATE CIRCUITS BEING REMOVED.)
GENERAL NOTES
WORK NOTES
E5 FOR CONTINUATION, SEE FLOOR 2- PORTE COCHERE REFLECTIVE LIGHTING
PLAN, THIS SHEET.
E6 FOR CONTINUATION, SEE FLOOR 2 - WALKWAY REFLECTIVE LIGHTING PLAN, THIS
SHEET.
E7 SEE THE E1.0 - ELECTRICAL SITE PLAN FOR BOLLARD CIRCUITING.
E8 PROVIDE A PHOTOCELL FOR LIGHTING CONTROL TO BOTH THE PORTE COCHERE
AND WALKWAY, WHICH AUTOMATICALLY FUNCTIONS AS A SHUT-OFF AT DAWN
AND TURNS ON AT DUSK.
LR1 REMOVE EXISTING WALL MOUNTED FIXTURE, LAMP, OTHER LIGHTING ABOVE
WALL MOUNTED FIXTURE,AND ALL ASSOCIATED WIRING.
0'2' 4' 10'
E2.2 3/16" = 1'-0"
FLOOR 2 - WALKWAY REFLECTIVE LIGHTING PLAN2
DESCRIPTION DATE
1 C-WEST COMMENTS 03.28.2017
File details come from the government source that posted it. Updated .