Attachment J-9 Volume 2 Facility Survey

View the file

Other files for this federal contract opportunity

Other files attached to Pinellas County JCC RFP, newest first.
File Type Posted
Sol_DOL-ETA-16-R-00053_Amd_000007.pdf PDF
Sol_DOL-ETA-16-R-00053_Amd_000006.pdf PDF
Sol_DOL-ETA-16-R-00053_Amd_000005.pdf PDF
Amendment_5_attachment.pdf PDF
Pinellas_Staff_Compensation_Report.pdf PDF
Sol_DOL-ETA-16-R-00053_Amd_000004.pdf PDF
Attachment_2_-_Revised_Attachment_J-1_to_Pinellas_RFP.pdf PDF
Sol_DOL-ETA-16-R-00053_Amd_000003.pdf PDF
Attachment_1_-_Pinellas_JCC_Questions _Answers.pdf PDF
Pinellas_County_JCC_Vehicle_List.pdf PDF
Attachment_3_-_Clause_L6_Revised_-_Pinellas_JCC.pdf PDF
DOL-ETA-16-R-00053_amendment_0001.pdf PDF
Attachment_J-12_Revised_Utilities_and_Fuel_Usage.pdf PDF
Attachment_J-13_National_Staff_Comp_Data_Report.xlsx XLSX spreadsheet
Attachment_J-5_List_of_Career_Technical_Skills_Training_(CTST)_Slots.pdf PDF
Attachment_J-16_MPO35 _MSO20 _CTT10.pdf PDF
Attachment_J-11_Revised_Inventory_Estimate.pdf PDF
Attachment_J-10_Property_Management_Listing.pdf PDF
Amendment_01.pdf PDF
Attachment_J.2.pdf PDF
Attachment_J.4.pdf PDF
Attachment_J.11_Pinellas_JCC_Inventory_of_Estimate_of_Expendables.docx DOCX document
Attachment_J.6.pdf PDF
Attachment_J.7_Past_Performance_Questionnaire.pdf PDF
Attachment_J-8.pdf PDF
Attachment_J.3.pdf PDF
Attachment_J.9_Pinellas_2012_Final_Vol1_Part1.pdf PDF
Attachment_J-1.pdf PDF
Attachment_J.12_Pinellas_Center_Utilities.pdf PDF
Sol_DOL-ETA-16-R-00053_Final.pdf PDF
Show all 30

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pinellas County

Job Corps Center St. Petersburg, FL

Facility Planning Report Volume II

Supporting Data

Final May 2013

Department of Labor/ Office of Job Corps

22Pinellas County Job Corps Center

Pinellas County

Job Corps Center St. Petersburg, FL

Facility Planning Report Volume II

Supporting Data

Final May 2013

Gymnasium and Recreation Building 8

33 Pinellas County Job Corps Center

CONTENTS

PINELLAS JOB CORPS CENTER

FACILITY PLANNING REPORT

VOLUME I - Planning Strategy

• Existing Site Plan

• Center Statistics

INTRODUCTION

• Purpose

• Report Contents

EXECUTIVE SUMMARY

A. EXISTING CONDITIONS

• Background

• General Site Conditions

• General Building Conditions

• Preventive Maintenance

• Ownership

• Facility Assessment by Function

• Energy Issues

• Environmental Issues

• Sustainability

• Accessibility Standards

• Completed and Current Projects Since the Last Survey

• Health and Life Safety Issues

• Summary of Defi ciencies

B. RECOMMENDATIONS

• Status of the Previous (PY09) Plan

• Signifi cant Issues

• PY 12 Plan Overview

• Summary of Proposed Projects

• Proposed Site Plan

C. PLANNING ANALYSIS

• Purpose

• Planning Objectives and Assumptions

• Space Utilization Analysis

• Federal Real Property Asset Management

• Mission Dependency Site Plan

• Defi ciency Analysis

• Facility Condition Summary Report

• Building Condition by Function

• Building Condition Site Plan

VOLUME II - Supporting Data

• Vicinity Map

• Location Map

• Existing Site Plan

D. DESCRIPTIONS

• Building and Structures

• Space Utilization By Function

• NSF by Building

• Energy Report

• Environmental Management

Radon Report

• Site Descriptions

• Building Descriptions

E. DEFICIENCIES

F. CORRESPONDENCE AND REPORTS

• Center Review Meeting Minutes

• Survey Brief

• Life Safety Defi ciencies Transmittal and List

• O & M Defi ciency List

• Active Warranty Report

• FRPC Performance Measures Matrix

44Pinellas County Job Corps Center

55 Pinellas County Job Corps Center

Pinellas C ounty Job C orps C enter

77 Pinellas County Job Corps Center

D Descriptions

BUILDINGS AND STRUCTURES

00428 PINELLAS COUNTY 05/29/2013

1Page: of Date:

0001 - ADMINISTRATION

0002 - STUDENT SERVICES

0003 - EDUCATION

0004 - HARD VOCATIONAL

0005 - CAFETERIA

0006 - DORMITORY

0007 - DORMITORY

0008 - GYMNASIUM & RECREATION

0009 - MAINTENANCE & OPERATIONS

0021 - PAVILION

0022 - GAZEBO

0023 - GAZEBO

0024 - GAZEBO

0025 - GAZEBO

0026 - GAZEBO

Name GSF

13,261 11,574 19,406 16,000 16,000 31,974 31,974 20,935 7,021

Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active

StatusType

Building Building Building Building Building Building Building Building Building Structure Structure Structure Structure Structure Structure

Use Group Built Flrs Const

Business Business Business Business Assembly Residential Residential Assembly Storage Assembly Assembly Assembly Assembly Assembly Assembly

Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good

ConditionAsset Number

0042800004 0042800005 0042800006 0042800007 0042800009 0042800008 0042800010 0042800011 0042800012 0042800018 0042800019 0042800020 0042800021 0042800022 0042800023

9 168,145

6 545

15 168,690

Buildings

Structures

Total

GSF

GSF

GSF

Summary

05/29/2013

Space Utilization By Function 00428 Pinellas County Page: 1 of Date:

HOUSING

EDUCATION

FOOD SERVICE

SUGGESTED

NSF/

ENROLLEE

SUGGESTED

TOTAL

NSF

ACTUAL

TOTAL

NSF

TYPE OF SPACE

SUB TOTAL

SUB TOTAL

SUB TOTAL

Resident Men Resident Women Total Residents

Residents 272 Non Residents 28

300Total Students

(272)

(300)

(300)

DIFFERENCE

27,200

14,660

5,400

39,992

35,278

8,110

Lounge Other Shower/Toilet Sleeping excl. SPD( rooms; beds) Storage

Academic (300) Non-Academic

20 -- ACT (Off-Ctr) 12 -- Carpentry + 40 -- Cert. Nursing Asst.

12 -- Electrical + 20 -- Facilities Maint. and Const. + 30 -- HVAC (Off-Ctr) 40 -- Medical Assistant 20 -- Medical Office Specialist 20 -- Pharmacy Tech + 12 -- Plumbing +

Vocational Theory (76)

Dining (2 Servings) Food Preparation Food Storage

7,000 3,848 5,616

22,908

7,020 7,935

3,850 2,900 3,000 3,850

1,150 3,000

4,180 2,800 1,130

2,720

3,264 19,584

1,632

1,600

1,500

1,200

2,400 1,800 1,200

4,280

2,352 3,324 -1,012

4,020 4,935

2,950 1,300 2,400 2,350

-326

2,400

1,780 1,000

-70

Vocations

12,792

20,618

2,710

05/29/2013

Space Utilization By Function 00428 Pinellas County Page: 2 of Date:

RECREATION

MEDICAL/DENTAL

ADMINISTRATION

STORAGE/SUPPORT

SUGGESTED

NSF/

ENROLLEE

SUGGESTED

TOTAL

NSF

ACTUAL

TOTAL

NSF

TYPE OF SPACE

SUB TOTAL

SUB TOTAL

SUB TOTAL

SUB TOTAL

TOTAL 251.17 75,350 115,028

(300)

(300)

(300)

(300)

DIFFERENCE

168,145

0.68

TOTAL GSF

NET TO GROSS RATIO

14,020

2,070

6,000

6,000

16,355

3,153

6,130

6,010

Aerobics/Exercise Arts & Crafts Canteen Gymnasium Learning Resource Center/Library Meeting Room Recreation Hall Recreation Office Theater Weight Room

Medical/Dental

Administration

Operations & Maintenance Warehouse

6.9

2,300 8,160

2,040

3,153

6,130

2,640 3,370

2,070

6,000

2,400 3,600

1,083

-230

RESIDENT

NON-RESIDENT

(272)

(28) 15

50 13,600

2,335

1,083

39,678

Net Square Footage By Building Date: 05/29/2013 Page: 1

Center: PINELLAS COUNTY (00428) of 4

HOUSING

Sleeping excl. SPD

Lounge

Storage

Shower/Toilet

Other

Function Suggested

NSF

11,454 11,454

3,500 3,500

2,808 2,808

1,924 1,924

0006 - DORMITORY

0007 - DORMITORY

0007 - DORMITORY

0006 - DORMITORY

0006 - DORMITORY

0007 - DORMITORY

0007 - DORMITORY

0006 - DORMITORY

0006 - DORMITORY

0007 - DORMITORY

Bldg Name Actual NSF Difference

22,908

7,000

5,616

3,848

Sub Total: 39,992

19,584

2,720

1,632

3,264

27,200

3,324

4,280

-1,012

2,352

3,848

( 272

12,792 rooms; beds rooms; beds

Page: 2

Center: PINELLAS COUNTY (00428) of 4

EDUCATION

Academic

Vocational Theory (76)

Carpentry

Electrical

Plumbing

Facilities Maint. and Const.

Medical Assistant

Non-Academic

Pharmacy Tech

Medical Office Specialist

Cert. Nursing Asst.

Function Suggested

NSF

1,200

1,800

3,850

3,000

3,000

3,850

6,000

1,175

1,150

2,900

0003 - EDUCATION

0003 - EDUCATION

0003 - EDUCATION

0002 - STUDENT SERVICES

0003 - EDUCATION

0002 - STUDENT SERVICES

0003 - EDUCATION

0002 - STUDENT SERVICES

0002 - STUDENT SERVICES

0003 - EDUCATION

0004 - HARD VOCATIONAL

0004 - HARD VOCATIONAL

0004 - HARD VOCATIONAL

0004 - HARD VOCATIONAL

0003 - EDUCATION

0002 - STUDENT SERVICES

0008 - GYMNASIUM & RECREATION

0003 - EDUCATION

0003 - EDUCATION

0003 - EDUCATION

0003 - EDUCATION

Bldg Name Actual NSF Difference

7,020

3,850

3,000

3,000

3,850

7,935

1,150

2,900

Sub Total: 35,278

3,000

1,500

1,200

3,000

1,600

14,660

4,020

2,950

2,400

2,400

2,350

-326

4,935

1,300

( 300

20,618

Page: 3

Center: PINELLAS COUNTY (00428) of 4

FOOD SERVICE

RECREATION

MEDICAL/DENTAL

ADMINISTRATION

Dining (2 Servings)

Food Preparation

Food Storage

Recreation Hall

Arts & Crafts

Gymnasium

Weight Room

Theater

Canteen

Aerobics/Exercise

Meeting Room

Learning Resource Center/Libr

Recreation Office

Medical/Dental

Administration

Function Suggested

NSF

4,180

2,800

1,130

2,040

8,160

2,300

3,153

6,130

0005 - CAFETERIA

0005 - CAFETERIA

0005 - CAFETERIA

0008 - GYMNASIUM & RECREATION

0008 - GYMNASIUM & RECREATION

0008 - GYMNASIUM & RECREATION

0008 - GYMNASIUM & RECREATION

0008 - GYMNASIUM & RECREATION

0005 - CAFETERIA

0008 - GYMNASIUM & RECREATION

0005 - CAFETERIA

0008 - GYMNASIUM & RECREATION

0008 - GYMNASIUM & RECREATION

0001 - ADMINISTRATION

0001 - ADMINISTRATION

Bldg Name Actual NSF Difference

4,180

2,800

1,130

2,040

8,160

2,300

3,153

6,130

Sub Total:

Sub Total:

Sub Total:

Sub Total:

8,110

16,355

3,153

6,130

2,400

1,800

1,200

2,070

6,000

5,400

14,020

2,070

6,000

1,780

1,000

-70

1,083

2,710

2,335

1,083

Page: 4

Center: PINELLAS COUNTY (00428) of 4

STORAGE/SUPPORT

Warehouse

Operations & Maintenance

Function Suggested

NSF

3,370

2,640

0009 - MAINTENANCE & OPERATIONS

0009 - MAINTENANCE & OPERATIONS

Bldg Name Actual NSF Difference

3,370

2,640

Sub Total: 6,010

3,600

2,400

6,000

-230

( 300

Energy Management Report Center: PINELLAS COUNTY (00428)

Page: 1 Date: 05/29/2013 of 3

CENTER ENERGY DATA

Deferred (new center)

ENERGY CONSUMPTION ASSESSMENT

0% 48,948

57,135 48,948

ENERGY USE BY FUEL TYPE

Energy Audit :

Date of Audit :

Electric Company :

Percent Change since Baseline Year :

Natural Gas Company :

Property Status :

Progress Energy Florida Peoples Gas

Federally Owned (DOL)

2,023,311 6,904=

Total 8,231

MBtu

MBtu

Total $256,854 MBtu/ $31.206

BTU/GSF

BTU/GSF

BTU/GSF

Electricity

Natural Gas kWh

1,287 MCF = 1,327 MBtu

$242,317 $0.120= kWhElectricity

Natural Gas $14,537 = $11.295 MCF

ENERGY COST BY FUEL TYPE

WATER CONSUMPTION ASSESSMENT

Percent Reduction Since Baseline Year:

1,000 Gallons

1,000 Gallons

FY 2012 Energy Goal:

Further Reduction in Energy Usage is needed to meet Energy Reduction Goals.

FY 2012 Energy Consumption:

Note: The Federal Government has set a goal of 3% Energy Consumption Reduction per year in EO 13423.

2,260 2,034 3,060

- 35%

Further Reduction in Water Usage is needed to meet Water Reduction Goals.

Note: The Federal Government has set a goal of 2% Water Consumption Reduction per year in EO 13423.

FY 2012 Goal:

FY 2012 Water Consumption:

1,000 Gallons

FY 2012 Energy Baseline:

FY 2011 Baseline:

Page: 2 of 3

Implementing some of the below recommendations can save you 10% to 25% off your annual energy bill without negatively impacting comfort or productivity.

1. Your staff and students are the key to savings. Educate the students and staff on the why of energy saving - costs and environmental impacts. Encouraging them to actively participate in energy reduction is also important. Post reminders at exit doors and bulletin boards about energy conservation. Simple tips include:

a. Turn it down (lights, heating & cooling),

b. Turn it off (lights, computers, other equipment),

c. Keep it tight (close doors and windows, use window blinds)

2. Operations and Maintenance: Educate the O&M staff on the why of energy saving -costs and environmental impacts. Simple tips include:

a. Make sure that the Operations and Maintenance staff is properly trained for the equipment they operate.

b. Tune and clean HVAC: Perform seasonal cleanups on air conditioners, boilers and furnaces, and regularly clean cooling coils and drain pans. Get rooftop or outdoor condenser coils cleaned and maintain an appropriate filter changing schedule.

c. Check (or ask your HVAC contractor to check) your outside air dampers or economizers to verify proper ventilation. Make sure economizer controls function properly. Make sure automatic dampers close during unoccupied periods.

d. Restore automatic control: When troubleshooting a system, take time to figure out and repair the automatic controls. Today's quick fix is tomorrow's bad idea.

e. Reasonable set points: Try 68°F in the heating season and 75°F in the cooling season.

f. Schedule HVAC equipment and lighting: (weekdays, weekends, holidays, off-season). Make sure equipment runs only when it is needed and the buildings are occupied. When buildings are vacant (i.e. dormitories during the day with students in class), make sure all the lights in the building are off.

g. Seasonal (resets, schedules, and shutoffs): As the seasons change, adjust set points and schedules to match the system's response to the weather.

h. Lighting: Invest in an inexpensive light level meter to measure the foot-candles in spaces to determine whether or not they are over lit and lamps can be safely removed. Where four-lamp fixtures are in use, two lamps can usually be removed from every fixture or every other fixture. After lamps are removed, disconnect ballasts. Contact the Energy team at PBDewberry for suggested light levels for individual space types. Cleaning fixtures regularly increases light levels.

i. Utilize power management features for all computers and monitors to shut them off when idle for more than 15 minutes.

Page: 3 of 3

j. Have your vending machine suppliers turn off or remove light tubes from the advertising lighting in the machine. This will save about $50 per year per vending machine.

k. Save water with low flow sink aerators (0.5gpm) and low flow shower heads (1.5gpm - 2.0gpm). This will also reduce water heating energy consumption.

l. Set your water heater to 120°F. Verify by measuring at the tap. Never go below 115°F.

m. For water heaters installed in unconditioned spaces, add insulation blankets making sure that access covers, electric connection areas, and pressure relief valves are left uncovered.

n. Caulk and fill cracks around doors and windows to reduce costly air leaks.

o. When replacing broken glass, use high transmittance, low heat gain windows.

p. Make sure automatic door closers are functioning properly to avoid drafts.

3. Buy energy efficient, buy EnergyStar (www.energystar.gov).

a. Buy EnergyStar appliances and equipment.

b. Replace burned out lightbulbs with EnergyStar labeled compact fluorescent lightbulbs (CFLs).

c. Replace broken thermostats with EnergyStar labeled programmable products.

d. Replace broken exit signs with EnergyStar LED exit signs.

Environmental Management Report

Page: 1 Date: 05/29/2013 of 1

SOLID & HAZARDOUS WASTE MANAGEMENT (RCRA)

Municipal Waste Service

HAZARDOUS MATERIALS STORAGE (EPCRA)

N/A

No

PETROLEUM UNDERGROUND STORAGE TANKS (RCRA)

Compliance0

PETROLEUM ABOVEGROUND STORAGE TANKS (CWA)

ASBESTOS AND PCB MANAGEMENT (TSCA)

AIR POLLUTION CONTROL (CAA)

None

Non-Attainment

Solid Waste Disposal :

Hazardous Waste Generator :

Hazardous Waste ID :

Generator Classification :

Hazadous Materials Storage :

Hazardous Materials ID :

HazMat Storage Area :

HazMat Spill Response Plan :

Number of Regulated USTs :

Number of Un-regulated USTs :

Local Hazardous Use Permit :

LEPC Notification :

EPA Generator ID Number :

Hazardous Waste Disposal :

RCRA Compliance

ID LocationFuel Type Capacity

Number of ASTs :

Asbestos Survey Date :

Asbestos Type :

Asbestos Coordinator :

Coordinator Training Date:

Custodial/Maintenance Training :

AHERA Regulated :

Management Plan Approval :

PCB Transformer Testing :

PCB Transformers :

PCB-Contaminated Transformers :

Transformers Labelled :

Regional Air Quality :

Permitted Air Pollution Source :

Source Description :

City of Saint Petersburg No

N/A

N/A N/A

Overfill Leak Corrosion

SPCC Plan Required : SPCC Plan Completed :

No N/A

No Survey Required due to Age of Buildings None

N/A N/A

No

No

Lead

ID Fuel Type Capacity Location Overfill

Prevention Secondary ContainmentTank Status

Tank Status Prevention/Detection

Radon

Date: 05/29/2013Center : Pinellas County (00428) Page: 1 of 1

0001 - ADMINISTRATION

0002 - STUDENT SERVICES

0003 - EDUCATION

0004 - HARD VOCATIONAL

0005 - CAFETERIA

0006 - DORMITORY

0007 - DORMITORY

0008 - GYMNASIUM & RECREATION

0009 - MAINTENANCE & OPERATIONS

Bldg Name Test Date

No

No

No

No

No

No

No

No

No

Radon Testing

Test Result

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Mitigation Mitigation Date

RADON EXPLANATORY NOTES

The US Environmental Protection Agency (EPA) has established a radon action level of 4.0 picoCuries per liter (pCi/L). Occupied buildings with radon concentrations less than 4.0 pCi/L do not require radon mitigation; un-occupied buildings, or those buildings which are occupied only infrequently for brief periods of time, also do not require radon mitigation. Occupied buildings with radon concentrations greater than

4.0 pCi/L require radon mitigation and verification of radon reductions as soon as possible, with priority given to dormitories and student recreation buildings. Occupied buildings with radon concentrations greater than 20.0 pCi/L should be considered significant radon exposure hazards, and priority for mitigation should be given to buildings with these highly elevated radon concentrations.

Radon mitigation techniques include: (1) adjustment of the building HVAC system to create a positive pressure within the building; (2) sealing of foundation wall cracks, penetrations, or other openings;

(3) sealing crawlspace openings and sump pits; (4) installing an active subslab depressurization (ASD) system.

Site Description

PINELLAS COUNTY

View of Central Plaza from Dormitory Building 7 roof

Page: 1 Date: 05/29/2013 of 4

Paving Type for Roads & Parking Paving Type for Sidewalks

Asphalt Concrete

Comments:

Topography Buildings and Structures

Center is not fully enclosed by fencing. The campus is effectively planned to create a protected inner zone.

Buildings form part of the periphery. Wrought iron fencing is provided between buildings to enclose the central plaza. The area behind the cafeteria and the ball field is enclosed by chain link fencing.

ROADS, PARKING & SIDEWALKS

Water Source Water Authority Service Meter On-Site Treatment Plant

1. Water System

Treatment Type Storage Type Storage Capacity(Gallons)

NoMasterCity of St. PetersburgCity of St. Petersburg

None 0None

There is a domestic water booster pump package in Building 9 (three 5HP pumps to maintain 65 PSI).Comments:

Fire Hydrants On-Site Water Supply Storage Capacity

(Gallons) Pressure Source FD Response Time (Minutes)

Yes 0 4None Municipal

Sewage Treatment Flow

City of St. Petersburg

City of St Petersburg

City of St. Petersburg

Gravity

Maintenance ResponsibilityOwnership

Number of Deficiencies = 1SITE FEATURES

UTILITIES

3. Sanitary Sewer System/ Sewage Treatment Plant

2. Fire Protection System

Buildings Structures9 6Flat

Surrounding

Outdoor Recreation

Light Industrial

Field

Behind Cafeteria and Ballfield

Between Buildings

Chain Link

Wrought Iron

Location Type

Maintenance Responsibility System Capacity Adequate System Condition

Center Center Yes Good

Separate Loop

Yes

Ownership Maintenance Responsibility System Capacity Adequate System Condition

Center Center Yes Good

System Capacity Adequate System Condition

Yes Good

Ownership

Roads & Parking Adequate Roads & Parking Condition Sidewalks Adequate Sidewalk Condition Yes Good Yes Good

Number of Deficiencies = 1

Fencing

Other Features

Page: 2 Date: 05/29/2013 of 4

Peoples Gas

Comments:

Electric Company PCB Trans.

Transformer Mounting Transformer Ownership

Systems Ownership Maintenance Responsibility

Progress Energy Florida

The overhead service is delivered to the center from a power pole located along 20th street , where it dips underground and loops around the exterior perimeter of the center providing power to six pad-mounted, utility owned step down transformers located near and serving individual Buildings 1, 5, 7 and groups of buildings:

Buildings 2 and 3, 6 and 8, and 4 and 9. All buildings have individual secondary, solid state, utility meters. Building 5 is provided with an automatic transfer switch (ATS) with a CAM Lock for generator connection. One distribution panel of the north wing of Dormitory Building 6 is provided with an ATS, which through the safety switch with a CAM Lock, could be connected to a generator. Three pressure pumps in Maintenance/Operation Building 9 providing pressure for the water systems are also provided with an ATS. Progress Energy Florida owns and maintains all primary utilities, transformers and metering.

Pad Utility

Utility Utility

No

12470Y/7200, 3-phase, 4wire

208/120, 3-phase, 4wireUnderground

UndergroundPrimary Service

Secondary Service

Distribution Characteristics

5. Fuel Distribution System

Number of Deficiencies = 2

4. Storm Water System

Drain Type On-Site Storm Water Management

Surface Runoff Detention Pond

Ownership Maintenance Responsibility System Capacity Adequate System Condition

Center Yes GoodCenter

Gas Company Metering

Master

Ownership Maintenance Responsibility System Capacity Adequate System Condition

Center Center Yes Good

7. Electrical (Service)

Transformer Maint Resp

Utility

System Capacity Adequate System Condition

Yes Good

Generator

None

ATS MTS

Yes No

6. Central Plant: None

Metering Individual

Page: 3 Date: 05/29/2013 of 4

ACCESSIBILITY

Yes

UnknownUnknownUnknownNo

Nationally Registered Site

Site Eligible for National Register

Located in Historic District

Archaeological Significance

Comments:

Telephone Company

On-site Line Owner

The local telephone network is provided by Verizon. The long distance (VoIP) and data networks are provided by Job Corps Data Center. Four T1 lines entering the main center phone and data closet MC located in the data room in Administration Building 1. Two UPS batteries buffer power surges and drops in the line voltage and maintains the power requirement of the system for 15 to 30 minutes. Buildings are connected to the MC by fiber optic cable.

Connection in the buildings from the switches to the outlets is by CAT 5. There are eight land lines provided by Verizon. There are 10 digital Fax lines and 100 phone lines provided through the VoIP. A central fire alarm control/annunciator panel located in the security office in Building 1 monitors all fire alarm and security panels at the center. The last fire alarm inspection report was done 8/14/2012 by ACSI Alarm and Communication System Inc. ((813) 873-1851). There are magnetic door alarms at the wing exits in Dormitory Buildings 6 and 7. There is direct TV in Dormitory Buildings 6 and 7, and Buildings 1, 2 and 8.

Verizon

Maint. Responsibility

Center Center

Door alarms

Earthquake Risk

Low Medium LowHigh MediumIBC High

LightningEarthquake Def. Authority Flooding Tornado Hurricane Forest

Fire

Number of Deficiencies = 1

Accessible Parking: Accessible Slope:

Yes

Curb Cuts:

Yes

Ramps:

N/AYes

Site Accessible Route:

HISTORIC PRESERVATION

9. Electrical (Communication/Alarm/Security)

NATURAL HAZARDS

Yes

Central

VOIP

System Capacity Adequate System Condition

GoodYes

8. Electrical (Site Lighting)

Roadways Parking Walkways Building Outdoor Sports

Mounting

Control

Pole Pole Pole Building None

Photocell Photocell, Time Clock Photocell, Time Clock Photocell, Time Clock None

System Ownership Maintenance Responsibility System Capacity Adequate System Condition

Center Center Yes Good

Comments: Wall-mounted and pole-mounted lighting within the center property lines belongs to and is maintained by the center and is served from the respective buildings. All lights are divided into two groups: the security lighting controlled by the roof-mounted photocells through the security lighting contactors and the energy saving lighting controlled by the time clocks through the energy saving lighting contactors. Pole-mounted street lighting along 5th Street and 22 Street belongs to and is maintained by the utility.

Number of Deficiencies = 2

STORAGE TANKS: None

Fire Alarm Security

Page: 4 Date: 05/29/2013 of 4

GENERAL SITE CONDITION

Rating X Good Fair Poor

The site condition is not impacting the functional use of the facilities.

The site condition IS impacting the functional use of the facilities.

The site condition IS SIGNIFICANTLY impacting the functional use of the facilities.

Building Descriptions and Utilities

BUILDING 1 - ADMINISTRATION

Building Descriptions

Page: 1 of 50

Building: 0001 - ADMINISTRATION

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Structural Steel, Concrete Steel

Brick Masonry Curtain Wall Stucco

Comments: There are aluminum sunshades along the building exterior walls.

Wall Roof Rigid Rigid

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Business 13,261 9,283 1 Owned 2009 Not Evaluated

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

N/A

Yes

Yes

N/A

Yes

Yes

N/A

N/A

Yes

N/A

N/A

ACCESSIBILITY

Structural Systems1.

Exterior Walls2.

Insulation4.

Material Drainage Year Life

Remaining Type Area Served

Metal

Built-up Roofing

Gutters and Downspouts

Interior Roof Drains

Arched

Flat

Vestibule

Offices

Number of Deficiencies = 13. Roof

Entire Building

Area Served

Page: 2 of 50

Building: 0001 - ADMINISTRATION

Comments: Awning windows have mosquito screens

INTERIOR FINISH

Carpet Concrete Epoxy Quarry Tile Resilient Vinyl Tile

CMU Ceramic Tile Drywall

Metal Unit - Metal Frame Wood Unit - Metal Frame

VERTICAL CIRCULATION

None

Metal Unit - Metal Frame Storefront - Storefront Frame

Awning Units - Aluminum Frame; Double Glazing; Fixed - Aluminum Frame; Double Glazing;

Acoustical Tile Exposed Structure Gypsum Board Metal Finish Panel Plaster

Exterior Doors5.

Windows6.

Floors1.

Interior Walls2.

3.

Interior Doors4.

Ceilings

Page: 3 of 50

Building: 0001 - ADMINISTRATION

Mechanical

Mechanical

Restroom

Janitor's Closet

Ventilation Area ServedExhaust Ventilation

Heat Source

Heat Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Building 1 is comprised of three distinct functions (security, medical/dental and administration) each with its own space. The security space is served by one system, air handler AHU-1A with electric heat (Carrier #FX4CNF042, 11.3 kW heater, mfd. 8/2008).

The medical/dental space is served by three systems, air handlers AHU-1B, C and D with electric heat (two Carrier #FX4CNF030, mfd. 12/2008; one #FX4CNF036, mfd. 8/2008).

The administration space is served by four systems. Two systems, air handlers AHU-1F and H with electric heat, are constant volume (Carrier #FX4CNF024, mfd. 10/2007; one #FX4CNF060, mfd.

11/2008, respectively). AHU-1H serves the communication hub and does not heat nor provide outdoor air.

The administration space is served by four systems. Two systems, air handlers AHU-1E and G with electric heat, are VVT systems (Carrier #40RM007, 9 kW, mfd. 8/2008; one #40MR008, 22 kW, mfd.

10/2008, respectively). AHU-1E supplies five zone dampers and has one bypass damper; AHU-1G supplies seven zone dampers and has two bypass dampers.

Comments:

Comments:

Comments:

Comments:

HVAC

Heat1.

Electric Resistance

Electric Resistance

Electric Resistance

Electric Resistance

Single Duct

Single Duct

Single Duct

Multi- Zone/Single

AHU

None

None

None

None

Electronic

Electronic

Electronic

Electronic

Mechanical

Mechanical

Mechanical

Mechanical

None

None

None

None

Offices

Medical/Dental

Offices

Offices

Ventilation2. Number of Deficiencies = 1

Page: 4 of 50

Building: 0001 - ADMINISTRATION

Cast Iron/PVC None Cast Iron

Electric Water Cooler Hose Bibb Lavatory Mop Sink Multi-Compartment Sink Shower Sink Water Closet (Flush Valve) Waterless Urinal

None

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Direct Expansion (Air

Source)

Split Direct Expansion (Air

Source)

Split Direct Expansion (Air

Source)

Split Direct Expansion (Air

Source)

Single Duct

Single Duct

Single Duct

Multi- Zone/Single

AHU

Refrigerant

Refrigerant

Refrigerant

Refrigerant

Electronic

Electronic

Electronic

Electronic

Mechanical

Mechanical

Mechanical

Mechanical

None

None

None

None

Offices

Medical/Dental

Offices

Offices

PLUMBING

The security space is served by one system, air handler AHU-1A with electric heat (Carrier #FX4CNF042, mfd. 8/2008).

The medical/dental space is served by three systems, air handlers AHU-1B, C and D with electric heat (two Carrier #FX4CNF030, mfd. 12/2008; one #FX4CNF036, mfd. 8/2008).

The administration space is served by four systems. Two systems, air handlers AHU-1F and H with electric heat, are constant volume (Carrier #FX4CNF024, mfd. 10/2007; one #FX4CNF060, mfd.

11/2008, respectively) and are provided cooling by two condensing units (Carrier #23ACA324, 2 ton, mfd. 9/2007; #24ACB360, 5 ton, 8/2008, respectively). AHU-1H serves the communication hub and does not provide outdoor air.

The administration space is served by four systems. Two systems, air handlers AHU-1E and G with electric heat, are VVT systems (Carrier #40RM007, mfd. 8/2008; one #40MR008, mfd. 10/2008, respectively) and are provided cooling by two condensing units (Carrier #38ARZ007, 6 ton, mfd.

8/2008; #38ARZ008, 7-1/2 ton, 9/2008, respectively). AHU-1E supplies five zone dampers and has one bypass damper; AHU-1G supplies seven zone dampers and has two bypass dampers.

Comments:

Comments:

Comments:

Comments:

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

3. Air Conditioning

Page: 5 of 50

Building: 0001 - ADMINISTRATION

None None ABC Type Fire Extinguisher

Comments: Underground service is provided from a 150 kVA utility-owned, pad-mounted transformer located east of the NE building corner to a 600A MCB distribution panel (GE APNB, Spectra series, 42 kA) located in the medical/dental wing electrical room. The 600A panel serves one 400A MCB distribution panel (from a 400A CB) in the administration wing, two 150A MCB panels (from two 150A CB) in the medical/dental wing, one 100A MCB panel (from a 100A CB) in the Security Building and a TVSS system (from a 60A CB). The 400A distribution panel in the administration wing serves one 250A MCB panel (from a 250A CB) and two 100A MCB secondary panels (from two 100A CB), all located in the same wing. Both distribution panels are provided witha surge protection systems (LEA International, SP200). The utility meter is mounted on the NE building corner.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Comments: Recorded footcandle levels include natural light contribution. Recessed direct/indirect T5 light fixtures are utilized throughout the building, with the exception of the utility rooms provided by wall/ceiling-mounted strip lighting. Lighting in the offices, conference room, and storages is controlled by passive infra-red, ultrasonic wall-mounted sensors. Lighting in the corridors, wards and the reception areas is controlled by dual technology passive infra-red and ultrasonic ceiling-mounted occupancy sensors. Incandescent light fixtures controlled by the dimmer are utilized in the main conference room.

Compact Fluorescent High Intensity Discharge (HID)

Comments: Strategically located exterior light fixtures are controlled by the roof-mounted photocell through the security lighting contactor. The rest of the exterior lighting is controlled by the time clock through the energy saving lighting contactor. Both lighting contactors are located in the main electrical room.

Inc and T5 - Fluorescent

T5 - Fluorescent

T5 - Fluorescent

T5 - Fluorescent

T5 - Fluorescent

T5 - Fluorescent

CFL + T5 - Fluorescent

T5 - Fluorescent

T8 - Fluorescent

Conference Rooms

Offices

Medical/Dental

Wards (Patient)

Reception

Corridors & Stairs

Toilets

Storage Rooms

Equipment Rooms (Elec/Mech)

Area Recommended Level

Recorded Level Light Type

Battery Backup Battery Backup

Main Distribution Panel 120/208V, 3-Phase, 4 Wire Panelboards Receptacles, GFCI, Switches

Sprinkler System Stand Pipe System Fire Suppression

Emergency Exit

FIRE PROTECTION

ELECTRICAL SERVICES Number of Deficiencies = 1

Exterior Lighting1.

Interior Lighting2. Number of Deficiencies = 1

Emergency /Exit Lighting3. Number of Deficiencies = 1

LIGHTING

Page: 6 of 50

Building: 0001 - ADMINISTRATION

FIRE ALARM

Comments: Two analog addressable fire alarm panels, a Faraday MCP-7000 and a Faraday MCP-6000 are located in the security area of the Security Building. The control/annunciator panel (Faraday MCP-6000) monitors duct smoke detectors in Buildings 1, 2, and 3 and exterior wall-mounted audio/visual devices in Buildings 2 and 3. The central control/annunciator panel (Faraday MCP-7000) monitors fire alarm panels in Cafeteria/Culinary Arts Building 5, Dormitory Buildings 6 and 7, Gymnasium Building 8 and control/annunciator panel (Faraday MCP-6000) in this building. The remote annunciator panel is mounted at the counter at the security area. The AHU units serving the building are provided with duct smoke detectors interconnected by relay for HVAC shut down. One smoke detector is provided above the fire alarm panels in the security area and one above the power extender panel (RSE-300) in the Security Building mechanical room.

Comments: This building is utilized as the main communication service entrance point for the center telephone and data systems. The DMARK for the telephone distribution/entrance is set in the data closet in the administration department. The center has (4) T1 lines which are provided by JCDC and managed by Verizon Communications for local and long distance calls. The room is cooled to protect the sensitive equipment. The equipment in this room has surge protection (Surge-Gap). The center utilizes a VoIP system installed and maintained by the JCDC. The equipment is manufactured by Cisco. The MC houses three Cisco 3800 series routers, a Catalyst 6500 switch, providing a platform for data, WAN, an Ethernet network, and a Blue Coat unit for transfer of an analog signal for digital fax lines. The system provides local and long distance calling, Voicemail and FAX service. The equipment is connected to two UPS back-up units (APC 10000W) providing backup power for up to 15 minutes.

Control/Annunciator Panel Duct Smoke Detector Remote Annunciator Panel Smoke Detector

Connected to Main System None None Satellite Dish

Telephone Security Public Address Television

GENERAL BUILDING CONDITION

Rating X Good

Fair Poor

COMMUNICATION

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Electric Water Gas No N/AYes

BUILDING UTILITY METERING

Structure: Good Exterior: Good Interior: Good Mechanical: Good Electrical: Good

BUILDING 2 - STUDENT SERVICES

Page: 7 of 50

Building: 0002 - STUDENT SERVICES

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Structural Steel, Concrete Steel

Brick Masonry Curtain Wall Stucco

Comments: There are aluminum sunshades along the building exterior walls.

Wall Roof Rigid Batt

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Business 11,574 7,984 1 Owned 2009 Not Evaluated

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

N/A

Yes

Yes

N/A

Yes

Yes

N/A

N/A

Yes

N/A

N/A

ACCESSIBILITY

Structural Systems1.

Exterior Walls2.

Insulation4.

Material Drainage Year Life

Remaining Type Area Served

Metal

Built-up Roofing

Gutters and Downspouts

Interior Roof Drains

Arched

Flat

Lobbies

Classrooms & Offices

3. Roof

Page: 8 of 50

Building: 0002 - STUDENT SERVICES

Comments: Awning windows have mosquito screens

INTERIOR FINISH

Carpet Concrete Epoxy Vinyl Tile

CMU Ceramic Tile Drywall

Metal Unit - Metal Frame Wood Unit - Metal Frame

Mechanical

Mechanical

Restroom

Janitor's Closet

Ventilation Area Served

VERTICAL CIRCULATION

None

Metal Unit - Metal Frame Storefront - Storefront Frame

Awning Units - Aluminum Frame; Double Glazing; Fixed - Aluminum Frame; Double Glazing;

Acoustical Tile Gypsum Board Metal Plaster

Exhaust Ventilation

Exterior Doors5.

Windows6.

Floors1.

Interior Walls2.

3. Number of Deficiencies = 1

Interior Doors4.

Heat Source

Heat Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Air handling unit AHU-2 (Carrier #39M21, mfd. 9/2008) provides supply air (VFD controlled) to 13 fan-powered VAV units, each equipped with an electric heater.

Comments:

HVAC

Heat1.

Electric Resistance

Variable Air Volume

None Electronic Mechanical None Entire Building

Ventilation2.

Page: 9 of 50

Building: 0002 - STUDENT SERVICES

The water heater (Lochinvar, 12 gallon, 2 kW) is located in the janitor's closet.Comments:

Cast Iron None Cast Iron

Electric Water Cooler Hose Bibb Lavatory Mop Sink Water Closet (Flush Valve) Waterless Urinal

None

None None ABC Type Fire Extinguisher

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Direct Expansion (Air

Source)

Variable Air Volume

Refrigerant Electronic Mechanical None Entire Building

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Two condensing units, CU-2-1 & 2 (Carrier #38AKS024, 20 ton and #38AKS016, 15 ton, both mfd.

9/2008) provide cooling to an air handling unit AHU-2 (Carrier #39MASTM04K1KC, mfd. 9/2008). AHU- 2 provides supply air (VFD controlled) to 13 fan-powered VAV units.

Comments:

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

3. Number of Deficiencies = 1Air Conditioning

Page: 10 of 50

Building: 0002 - STUDENT SERVICES

Comments: Underground service is provided from a 300A KVA utility-owned, pad-mounted transformer located east of the building's corner to a 600A distribution panel with a 500A MCB located in the electrical room. The distribution panel serves one two-section 400A MCB panel (from a 400A CB) and two 100A MCB panels (from two 100A CB) located in the main electrical room, one 100A MCB panel (from a 100A CB) located in the communication room , and two outdoor condensing units (from a 200A CB). The distribution panel is provided with a surge protection system (LEA International SP200). The utility meter is provided on the east exterior wall. Projectors are provided in the classrooms. Building 3 is served from the same utility transformer as this building.

FIRE ALARM

Comments: Duct smoke detectors and an exterior wall-mounted audio/visual device are controlled and monitored by the control/annunciator panel (MCP-6000) located in the security office in Building 1. The AHU unit serving the building is provided with a duct smoke detector for HVAC shut down.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Duct Smoke Detector Exterior Audible Alarm Exterior Visual Alarm

Comments: Recorded footcandle levels include natural light contribution. Recessed direct/indirect T5 light fixtures are utilized throughout the building, with the exception of the utility rooms which have wall/ceiling-mounted strip lighting. Lighting in the offices and storage rooms is controlled by wall-mounted, passive infra-red/ultrasonic sensors. Lighting in the corridors, lobby and the reception area is controlled by ceiling-mounted, dual technology, passive infra-red/ultrasonic occupancy sensors. Lighting in the classrooms is controlled by dual switching.

Compact Fluorescent High Intensity Discharge (HID)

Comments: Building-mounted exterior lighting consists of wall-mounted HID wall-packs and canopy-mounted recessed light fixtures with compact fluorescent lamps. Strategically located exterior light fixtures are controlled by the roof-mounted photocell through the security lighting contactor. The rest of the exterior lighting is controlled by the time clock through the energy saving lighting contactor. Both lighting contactors are located in the main electrical room.

T5 - Fluorescent

T5 - Fluorescent

T5 - Fluorescent

T5 - Fluorescent

T5 - Fluorescent

T5 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Offices

Classrooms

Conference Rooms

Lounges

Corridors & Stairs

Toilets

Storage Rooms

Equipment Rooms (Elec/Mech)

Area Recommended Level

Recorded Level Light Type

Battery Backup Battery Backup

Main Distribution Panel 120/208V, 3-Phase, 4 Wire Panelboards Receptacles, GFCI, Switches

Emergency Exit

ELECTRICAL SERVICES

Exterior Lighting1.

Interior Lighting2. Number of Deficiencies = 1

Page: 11 of 50

Building: 0002 - STUDENT SERVICES

Comments: This building is connected to the center's LAN system.

Connected to Main System None None Satellite Dish

Telephone Security Public Address Television

GENERAL BUILDING CONDITION

Rating X Good

Fair Poor

COMMUNICATION

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Electric Water Gas No N/AYes

BUILDING 3 - EDUCATION

Page: 12 of 50

Building: 0003 - EDUCATION

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Structural Steel, Concrete Steel

Brick Masonry Curtain Wall Stucco

Comments: There are aluminum sunshades along the building exterior walls.

Wall Roof Rigid Rigid

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Business 19,406 12,834 1 Owned 2009 Not Evaluated

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

N/A

Yes

Yes

N/A

Yes

Yes

N/A

N/A

Yes

N/A

N/A

ACCESSIBILITY

Structural Systems1.

Exterior Walls2.

Insulation4.

Material Drainage Year Life

Remaining Type Area Served

Built-up Roofing

Metal

Interior Roof Drains

Gutters and Downspouts

Flat

Arched

Classrooms

Lobbies

3. Roof

Page: 13 of 50

Building: 0003 - EDUCATION

Comments: Awning windows have mosquito screens

INTERIOR FINISH

Concrete Epoxy Vinyl Tile

CMU Ceramic Tile Drywall Exposed Structure

Metal Unit - Metal Frame Wood Unit - Metal Frame

Mechanical

Mechanical

Restroom

Janitor's Closet

Ventilation Area Served

VERTICAL CIRCULATION

None

Metal Unit - Metal Frame Storefront - Storefront Frame

Awning Units - Metal Frame; Double Glazing; Fixed - Aluminum Frame; Double Glazing;

Acoustical Tile Gypsum Board Metal Plaster

Exhaust Ventilation

Number of Deficiencies = 1

Exterior Doors5.

Windows6.

Floors1.

Interior Walls2.

3.

Interior Doors4.

Heat Source

Heat Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Air handling unit AHU-3 (Carrier #39M36, mfd. 9/2008) provides supply air (VFD controlled) to 17 fan-powered VAV units, each equipped with an electric heater.

Comments:

HVAC

Heat1.

Electric Resistance

Variable Air Volume

None Electronic Mechanical None Entire Building

Ventilation2.

Page: 14 of 50

Building: 0003 - EDUCATION

The water heater (Lochinvar, 12 gallon, 2 kW) is located in the janitor's closet.Comments:

Cast Iron/PVC None Cast Iron

Electric Water Cooler Hose Bibb Lavatory Mop Sink Water Closet (Flush Valve) Waterless Urinal

None

None None ABC Type Fire Extinguisher

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Direct Expansion (Air

Source)

Variable Air Volume

Refrigerant Electronic Mechanical None Entire Building

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Two condensing units, CU-3-1 & 2 (Carrier #38AKS028, 25 ton, both mfd. 9/2008) provide cooling to an air handling unit, AHU-3 (Carrier #39M36, mfd. 9/2008). AHU-3 provides supply air (VFD controlled) to 17 fan-powered VAV units.

Comments:

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

Page: 15 of 50

Building: 0003 - EDUCATION

Comments: Underground service is provided from a 300 kVA utility-owned, pad-mounted transformer located west of the NW building's corner to an 800A MCB distribution panel (GE APNB, Spectra series, 42 kA) located in the electrical room. The 800A panel serves one 600A/500A MCB panel (from a 500A CB) and three 100A MCB panels (from three 100A CB), all located in the main electrical room, and two condensing units (from a 200A CB). The distribution panel is provided with a surge protection system (LEA International, SP200).

The utility meter is provided on the west exterior wall. Projectors are provided in the classrooms. Building 2 is served from the same utility transformer as this building.

FIRE ALARM

Comments: Duct smoke detectors and an exterior wall-mounted audio/visual device are controlled and monitored by the control/annunciator panel (MCP-6000) located in the security office in Building 1. The AHU unit serving the building is provided with a duct smoke detector for HVAC shut down.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Duct Smoke Detector Exterior Audible Alarm Exterior Visual Alarm

Comments: Recorded footcandle levels include natural light contribution. Recessed direct/indirect T5 light fixtures are utilized throughout the building, with the exception of the utility rooms provided by the wall/ceiling-mounted strip lighting. Lighting in the offices and storage rooms is controlled by wall-mounted, passive infra-red/ultrasonic switches. Lighting in the corridors, lobby and the reception area is controlled by ceiling-mounted, dual technology, passive infra-red/ultrasonic occupancy sensors. Lighting in the classrooms is controlled by dual switching.

Compact Fluorescent High Intensity Discharge (HID)

Comments: Building-mounted exterior lighting consists of wall-mounted HID wall-packs and canopy-mounted recessed light fixtures with compact fluorescent lamps. Strategically located exterior light fixtures are controlled by the roof-mounted photocell through the security lighting contactor. The rest of the exterior lighting is controlled by the time clock through the energy saving lighting contactor. Both lighting contactors are located in the main electrical room.

T5 - Fluorescent

T5 - Fluorescent

T5 - Fluorescent

T5 - Fluorescent

CFL and T5 - Fluorescent

T8 - Fluorescent

Classrooms

Offices

Corridors & Stairs

Storage Rooms

Toilets

Equipment Rooms (Elec/Mech)

Area Recommended Level

Recorded Level Light Type

Battery Backup Battery Backup

Main Distribution Panel 120/208V, 3-Phase, 4 Wire Panelboards Receptacles, GFCI, Switches

Emergency Exit

ELECTRICAL SERVICES Number of Deficiencies = 1

Exterior Lighting1. Number of Deficiencies = 1

Interior Lighting2.

Page: 16 of 50

Building: 0003 - EDUCATION

Comments: This building is connected to the center's LAN system. The data room is provided with four Catalyst 3560-E series PoE-24 switches and a VG204 switch for digital data transfer to an analog format for the fax machine.

Connected to Main System None None TV with VCR

Telephone Security Public Address Television

GENERAL BUILDING CONDITION

Rating X Good

Fair Poor

COMMUNICATION

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Electric Water Gas No N/AYes

BUILDING 4 - HARD VOCATIONAL

Page: 17 of 50

Building: 0004 - HARD VOCATIONAL

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Structural Steel, Concrete Steel

Brick Masonry Stucco

Comments: There are aluminum sunshades along the building exterior walls.

Wall Roof Rigid Rigid

Metal Overhead - Steel Frame Metal Unit - Metal Frame

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Business 16,000 13,700 1 Owned 2009 Not Evaluated

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

N/A

Yes

Yes

N/A

Yes

Yes

Yes

N/A

Yes

N/A

N/A

ACCESSIBILITY

Structural Systems1.

Exterior Walls2.

Insulation4.

Exterior Doors5.

Material Drainage Year Life

Remaining Type Area Served

Built-up Roofing

Metal

Interior Roof Drains

Gutters and Downspouts

Flat

Arched

Classrooms

Shop Area

3. Roof

Page: 18 of 50

Building: 0004 - HARD VOCATIONAL

Comments: Awning windows and escape windows have mosquito screens

INTERIOR FINISH

Concrete Epoxy Open Grid Steel Vinyl Tile

Comments: Open grid steel flooring is at the mezzanine.

CMU Ceramic Tile Drywall

Metal Unit - Metal Frame Wood Unit - Metal Frame

VERTICAL CIRCULATION

Metal Stairs

Comments: Each shop has a metal stair to the loft storage area.

Awning Units - Aluminum Frame; Double Glazing; Escape Window - Aluminum Frame; Double Glazing;

Fixed - Aluminum Frame; Double Glazing;

Acoustical Tile Exposed Structure

Number of Deficiencies = 1

Windows6.

Floors1.

Interior Walls2.

3.

Interior Doors4.

Heat Source

Heat Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Each of the four vocational shop modules has a classroom and instructor's office served by an air handler with an electric heater (Carrier #FX4CNF042, 11.3 kW, mfd. 8/2008).

Comments:

HVAC

Heat1.

Electric Resistance

Single Duct None Electronic Mechanical None Classrooms and Offices

Page: 19 of 50

Building: 0004 - HARD VOCATIONAL

Mechanical

Dust Collection

Welding Fume Exhaust

Mechanical

Shop Area

Shop Area

Shop Area

Restroom

Comments:

Comments:

Comments:

Each of the four shops has an exhaust fan mounted high on the exterior wall and an intake louver at the other end of the shop.

The carpentry shop is equipped with a dust collection system (Aget #30SN90D1).

The facility maintenance shop is equipped with a welding exhaust system.

Cast Iron/PVC None PVC

Electric Water Cooler Fixed Emergency Eyewash Hose Bibb Lavatory Water Closet (Flush Valve)

None

None None ABC Type Fire Extinguisher

Ventilation Area Served

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Direct Expansion (Air

Source)

Single Duct Refrigerant Electronic Mechanical None Classrooms and Offices

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Exhaust Ventilation

Each of the four vocational shop modules has a classroom and an instructor's office served by an air handler (Carrier #FX4CNF042, mfd. 8/2008) provided cooling by a condensing unit (Carrier #24ACB342, 3-1/2 ton, mfd. 10/2008).

Comments:

Ventilation2.

System Type

Number of Deficiencies = 1

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

Number of Deficiencies = 1FIRE PROTECTION

Page: 20 of 50

Building: 0004 - HARD VOCATIONAL

Comments: Underground service is provided from a 300 kVA utility-owned, pad-mounted transformer located east of the building to a 1200A MCB distribution panel located in the main electrical room in the electrical shop.

The 1200A panel has (4) 200A and (4) 150A circuit breakers. The 1200A panel serves four 200A MCB and four 150A MCB panels (AQF3422CBX) providing for the shop loads. The 150A panels serve lighting and HVAC loads in the shops and the 200A panels with main shunt trip circuit breakers are controlled, each by three emergency shut off switches located at the shop entrances and in the instructor office. The main building distribution panel is provided with a surge protection system (LEA International, SP200).

The utility meter is provided on the east exterior wall. The cord real receptacles are ceiling-mounted in the middle of the shops. Projectors are installed in the classrooms. Building 9 is served from the same utility transformer.

FIRE ALARM

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

None

Comments: Recorded footcandle levels include natural light contribution. Recessed direct/indirect T5 light fixtures are utilized throughout in the classrooms and instructor's offices. The shops are provided with 250W HID industrial high bay light fixtures. The storage areas and utility rooms are provided by wall/ceiling-mounted strip lighting. Lighting in the offices is controlled by passive infra-red, ultrasonic wall-mounted switches.

Lighting in the shops is controlled by on/off switches. Lighting in the classrooms is controlled by both ceiling-mounted and wall-mounted infra-red and ultrasonic occupancy sensors.

Compact Fluorescent High Intensity Discharge (HID)

Comments: Building-mounted exterior lighting consists of wall-mounted HID wall-packs and canopy-mounted recessed light fixtures with compact fluorescent lamps.