This is a Geotechnical Report prepared by Amec Foster Wheeler Environment & Infrastructure Inc. for Brevard County and Taylor Engineering regarding sediment characterization in the Indian River Lagoon Area 1A near Melbourne, Florida. The report documents a comprehensive geotechnical investigation of approximately 152 acres adjacent to the Eau Gallie Causeway to support muck removal evaluation for environmental improvement of the Indian River Lagoon and enhanced navigability of the Intracoastal Waterway. The investigation included piston tube sampling at 54 locations with successful sample recovery at 18 locations, bathymetric probing on a 100-foot grid pattern, and extensive laboratory testing to characterize sediment properties. The field work was conducted between June 20-27, 2017, with sampling performed from a 19-foot pontoon boat at depths ranging from approximately 3 to 15 feet throughout the project area. The report identifies two distinct layers of soft muck sediments overlying sandy hard bottom, with muck thickness predominantly ranging from 0.25 to 2.5 feet across most of the area, though deeper deposits of 5 to 11 feet were identified along the southern boundary near the Eau Gallie Causeway.
Laboratory testing revealed sediment solids content ranging from 26 to 73 percent with corresponding fines content (material passing No. 200 sieve) ranging from 16 to 99 percent, indicating variable composition consistent with natural layering of sandy river sediments and organic muck. Organic content in muck samples ranged from approximately 3 to 12 percent. The two primary sediment classifications identified were dark grey organic silt with sand (USCS Classification ML/MH) and dark grey and brown silty sand with organics and shell fragments (USCS Classification SM). Column settling tests conducted on representative samples from seven boring locations demonstrated that when mixed to a 5 percent solids slurry, the materials achieved highly active settling within 24 hours, with solids content increasing to 48 to 64 percent within three days and water clarity improving from initial turbidity readings of 140 to 260 Nephelometric Turbidity Units (NTUs) to less than 3 NTUs. This data supports project planning for muck removal utilizing hydraulic and mechanical dredging methods, with the findings intended to delineate dredging limits and evaluate disposal alternatives for the proposed removal project.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Amec Foster Wheeler Environment & Infrastructure Inc.
1101 Channelside Drive, Suite 200 Tampa, Florida
USA 33602
Tel (813) 289-0750 Fax (813) 289-5474 www.amecfw.com
November 8, 2017
Mr. Jonathan Armbruster Vice President Waterfront Group Taylor Engineering, Inc.
10151 Deerwood Park Boulevard Building 300, Suite 300 Jacksonville, Florida 32256
Re: Indian River Lagoon Area 1A Muck Characterization Report
Indian River Lagoon Dredging Evaluation Melbourne, Brevard County, Florida Amec Foster Wheeler Project No. 300903.6
Dear Mr. Armbruster:
Amec Foster Wheeler Environment & Infrastructure, Inc. is pleased to present our Muck Characterization Report for the Indian River Lagoon Area 1A adjacent to the Eau Gallie Causeway.
The Indian River Lagoon Area 1A extends east of the Intracoastal Waterway covering approximately 152 acres. The project site is located in Melbourne, Brevard County, Florida.
The purpose of the investigation was to collect sediment samples from the Indian River Lagoon Area 1A, characterize the physical properties of the sediment, and identify the extents, depth, and thickness of the muck sediments to support the Brevard County’s Indian River Lagoon Dredging Evaluation.
We appreciate the opportunity to be of assistance with this project. If you have any questions regarding this report, please contact us.
Sincerely, Nickolas Depin, P.E.
Geotechnical Project Engineer
Michael P. Kelley, P.E.
Branch Manager Geotechnical and Mining Services
Attachment
For Bidding Purposes Only
Indian River Lagoon Area 1A Muck Characterization Report – Indian River Lagoon Dredging Evaluation
Melbourne, Brevard County, Florida Project Number: 300903.6
To: Mr. Jonathan Armbruster Taylor Engineering, Inc.
Date November 2017
From: Michael P. Kelley, P.E.
Amec Foster Wheeler Environment & Infrastructure, Inc.
TABLE OF CONTENTS
1.0 INTRODUCTION
1.1 Project Summary
1.2 Investigation Program
2.0 PROJECT SITE CHARACTERISTICS
2.1 Project Limits and Site Description
2.2 Brevard County Soil Survey
2.3 Previous Investigations
2.4 Geology
3.0 SAMPLING PROGRAM AND TESTING
3.1 Sampling Locations
3.2 Piston Tube Sampling
3.3 Bathymetric Probing
4.0 SEDIMENT LOCATION AND THICKNESS
5.0 SEDIMENT CLASSIFICATION TESTS
5.1 Column Settling Tests
6.0 SEDIMENT CHARACTERIZATION
7.0 CLOSING AND LIMITATIONS
8.0 REFERENCES
LIST OF TABLES
TABLE 1 Generalized Stratigraphic Units at Eau Gallie River
TABLE 2 Laboratory Summary Table
TABLE 3 4000 ml Column Settling Test Data Summary
LIST OF FIGURES
FIGURE 1 Site Location Map – Area 1A
FIGURE 2 Transects & Sample Locations – Area 1A
FIGURE 3 Bathymetric Survey Location Plan – Area 1A
FIGURE 4 Muck Thickness Cross Sections (1 of 3) – Area 1A
FIGURE 5 Muck Thickness Cross Sections (2 of 3) – Area 1A
FIGURE 6 Muck Thickness Cross Sections (3 of 3) – Area 1A
FIGURE 7 Muck Thickness Map – Area 1A
LIST OF APPENDICES
APPENDIX A Site Geology – Area 1A
APPENDIX B Piston Tube Sampling Logs
APPENDIX C Atterberg Limits and Mechanical Gradation Test Results
APPENDIX D Column Settling Test Results
Taylor Engineering, Inc. Amec Foster Wheeler Project No. 300903.6 Brevard County IRL Area 1A November 2017 Muck Characterization Report Page 3
1.0 INTRODUCTION
1.1 Project Summary
Brevard County is considering muck sediment removal options to improve the quality of the Indian River Lagoon (IRL). The muck removal is required to improve environmental aspects of the IRL. Additional secondary benefits of muck removal include improved navigability within the Intracoastal Waterway (ICWW) and IRL. Brevard County identified 4 areas extending north of the Eau Gallie Causeway and south of the Eau Gallie River (EGR). The designated dredge evaluation areas are denoted as Area 1, Area 1A, Area 2 and Area 4. The areas extend from approximately 1500 feet south and approximately 4000 feet north of the of the EGR mouth.
Area 3 was previously surveyed by the St. Johns River Water Management Department as part of the ongoing Eau Gallie River dredging project. The IRL Area 1A is located adjacent to the Eau Gallie Causeway and east of the ICWW, covering approximately 152 acres in Melbourne, Brevard County, Florida as shown on Figure 1.
As part of the IRL Dredging Evaluation, Amec Foster Wheeler Environment & Infrastructure, Inc.
(Amec Foster Wheeler) performed a geotechnical investigation throughout Area 1A, as shown on Figure 2. This work was performed under the direction of Taylor Engineering, Inc. (Taylor).
The geotechnical investigation was performed to determine the extents and thickness of the fine-grained organic sediment (muck) layer(s); and to characterize the physical properties of the muck and underlying sandy layers. It is anticipated that muck removal will be accomplished using hydraulic and mechanical dredging methods. The purpose of this geotechnical investigation was to develop data to support the delineation of the project dredging limits and evaluation of muck disposal alternatives.
1.2 Investigation Program
Amec Foster Wheeler’s field and laboratory investigation program included the following:
• Developed a sediment sampling plan based on Florida Department of Environmental Protection (FDEP) guidance documents for muck removal.
• Attempted piston tube samples and completed probing at 54 locations.
• Collected piston tube samples within the muck layers at 18 locations.
• Logged and classified recovered sediment samples in general accordance with visual manual classification method (ASTM D 2488) and the Unified Soil Classification System
(USCS) (ASTM D 2487).
• Conducted laboratory testing to determine the physical properties of the sediments and to evaluate performance and characteristics of the sediment during dredging and disposal.
Transects with sediment sampling locations are shown on Figures 2.
Muck Characterization Report Page 4
2.0 PROJECT SITE CHARACTERISTICS
2.1 Project Limits and Site Description
The project limits of Area 1A, as designated by Brevard County, extend 2,500 feet north of the Eau Gallie causeway at the southern project boundary and approximately 3,200 feet across the Indian River Lagoon east of the ICWW. The area along the southern boundary of the IRL Area 1A is bounded by the Eau Gallie causeway shoreline. The water depth throughout the project area varied from approximately 3 feet to 15 feet.
2.2 Brevard County Soil Survey
The data from the Soil Survey of Brevard County, (USDA-NRCS, 2013) was reviewed as part of the investigation. The soils in the submerged IRL areas are not mapped. The mapped soil units around the perimeter of site are shown in Appendix A. A brief description of the soil units identified along the western perimeter of the IRL project area is as follows:
• The predominant soil unit is identified as “Canaveral-Urban land complex” (map unit symbol 10). This unit consists of excessively drained soils with gradual slopes of less than 2%. The unit has a seasonal high groundwater table (SHGWT) at 30 inches (2.5 feet) and typically consists of fine sands. Permeability is very high and ranges from
19.98 to 50.02 in/hr.
• It is likely that similar soils to those mapped in the soils survey were eroded away with the formation of the lagoon area and may be present beneath the water surface, comprising a portion of the IRL and Intracoastal Waterway floor. It is also likely that areas immediately behind the seawalls have been backfilled to achieve the current grades around the perimeter of the lagoon.
2.3 Previous Investigations
In 2015, Amec Foster Wheel conducted a geotechnical site investigation that included the EGR harbor area and upper reaches of the river. The investigation identified a substantial thickness (up to 15 feet) of organic muck sediments throughout the harbor and reach areas overlying clayey and sandy river bottom.
In May 2017, Amec Foster Wheeler conducted a geotechnical site investigation that included the EGR channel area to the ICWW channel (Area 3 on Figure 1). The investigation identified a typical thickness of muck, between 1 and 2 feet, throughout the sampling area, with localized areas of muck up to 5 feet in thickness along the EGR channel.
2.4 Geology
Published geologic data indicate these sands or fluvial deposits represent a portion of the Holocene to Pleistocene sediments that extend to depths of 50 to 75 feet below mean sea level (msl) at the subject site. The first recognizable lithostratigraphic unit occurring below the sediments at the project site is the Anastasia formation of the Late Pleistocene age, which is represented as Qa in Appendix A. The Anastasia Formation is variably thick, though typically more than 60 feet thick along the Atlantic Coast Ridge and thins eastward.
Muck Characterization Report Page 5
The Anastasia Formation is comprised of variable amounts of quartz sand, shell and poorly to well-cemented coquinoid limestone. Underlying the Anastasia, is the Miocene Aged Hawthorn Group containing a mixture of various sediments including quartz sand, silt, clay, carbonates and phosphates. The thickness of the Hawthorn group can exceed 100 feet in this area of Brevard County. The Hawthorn sediments act as confinement for the underlying limestones of Eocene Age (Ocala Limestone and Avon Park Formation) which comprise the upper boundary of the Floridian Aquifer system. The near-surface geology in the general vicinity of Eau Gallie Channel is presented in Table 1.
TABLE 1 Generalized Stratigraphic Units at Eau Gallie River
Geologic Age
Stratigraphic Unit
Approximate Thickness
(ft)
General Lithologic Character
Holocene (Recent)
Undifferentiated deposits
50 - 75 Fine sand, clayey and silty sand, muck, and peat
Pleistocene Anastasia Formation 30 - 100
Fine sand, coquina shell, sandy and shelly limestone
Pliocene
Undifferentiated deposits
10 - 50 Fine sand, shell and marl
Hawthorn Group 100 - 200 Clay, clayey sand, silty sands, fine sand, phosphate, thin beds of carbonates
Miocene
Eocene
Ocala Limestone 100 Porous, marine limestone, soft, granular to chalky, highly fossiliferous
Avon Park Formation 1000+ Soft, dense, chalky limestone local zones altered to light brown, hard, crystalline dolostone
Muck Characterization Report Page 6
3.0 SAMPLING PROGRAM AND TESTING
3.1 Sampling Locations
Sample locations in IRL Area 1A were defined and prescribed in a similar fashion to the recommendations set forth in the Florida Department of Environmental Protection’s (FDEP) “Indian River Lagoon Basin Management Action Plans (BMAPs), Muck Removal Project Credit Guidance” (September 2012). Since the IRL dredging evaluation areas are adjacent to the Eau Gallie River study area, it was treated as a single discrete study area with unique watershed contributing area, physical infrastructure, and geomorphic characteristics. Consistent with the guidance, the IRL Area 1A study area included 6 transects at an approximate 500-foot spacing.
Each transect included approximately 10 sample locations at approximately 250-foot centers.
The study area boundary, transects and sediment sampling locations are shown as Figure 2.
3.2 Piston Tube Sampling
Piston tube sampling was attempted at 54 locations throughout Area 1A as shown on Figure 2.
The piston tube sampling was performed between June 21, 2017 and June 26, 2017 by an Amec Foster Wheeler field crew. The piston tube samples were collected from a 19-foot Pontoon boat.
The piston tube sampler is comprised of a stainless steel thin-walled, 2-inch diameter by 18-inch long sampling tube with 5-foot long threaded rod extensions. The sampler is advanced by hand and typically cannot penetrate a relatively stiff muck or medium dense sand layer given the diameter and length of the sampling tube. In general, piston tube sampler recovery is limited to soft/loose sediments. Prior to sampling, all piston tube locations were hand probed with a steel rod to determine the approximate top of sediment and thickness of the soft/loose muck layer.
The piston sampling was performed over discreet depth intervals, typically 2 to 4-foot thick zones within the muck layer. Samples collected from discreet depth intervals were collected in sealed jars, and composite samples of the entire muck column were collected in buckets. All samples were labeled with sample identification numbers and depths for subsequent logging and testing.
Piston tube sampling was attempted at each of the points designated on Figure 2. Given the sandy nature of the sediments throughout the IRL Area 1A, the piston tube sampler was unable to be advanced through relatively dense zones or the sediment sample was unable to be recovered at several locations. Where piston sampling did not recover sample, a hand probe with steel rod was completed to prove the depth to hard bottom. The probes typically indicated interbedded layers of sand and muck overlying a hard sandy bottom. The sampling and probing locations are distinguished by green and red markers, respectively, on Figure 2.
The elevation of the sediment surface at each sampling location was recorded by measuring the depth of the sampler from the water surface to the top of sample extraction zone. Amec Foster Wheeler surveyed the location and elevation of each piston tube sample using a handheld Garmin GPS 72 model with a horizontal accuracy of +/- 5 feet. The location data was collected in Graphic Coordinate System (GCS) WGS 1984. The water elevation during sampling was referenced to a staff gauge located at the Eau Gallie Causeway Bridge and ICWW Channel markers. The water elevation varied between -1.0 feet and -0.5 feet mean sea level (MSL)
Muck Characterization Report Page 7 during sampling. For the purposes of logging the piston tube sample depths, an average water elevation of -0.60 feet was used as the baseline elevation for all sample points, consistent with the previous Eau Gallie River investigation.
Piston tube samples were transferred to Amec Foster Wheeler’s Tampa, Florida materials testing laboratory for logging and laboratory testing. Amec Foster Wheeler’s engineers and geologists familiar with the field procedures and soil classification logged the cores in the laboratory in general accordance with ASTM D 2488 (Visual-Manual Description of Soils). The piston tube sampling logs are shown in Appendix B.
3.3 Bathymetric Probing
A bathymetric survey using hand soundings was conducted throughout the project area on an approximate 100-foot grid pattern as shown on Figure 3. The hand soundings were accomplished utilizing a 1-inch diameter rod with a 1-inch flat foot. The relatively small foot (as compared to typical bathymetric surveys over sandy marine sediments) was utilized for the soundings operation in order to acquire a higher degree of data accuracy and consistency for estimation of quantity of soft sediment in the project area. Mounted atop the rod was a GNSS receiver to accommodate real-time data collection using RTK base-rover survey methodology.
At each grid point, the rod was lowered carefully until it struck bottom to locate the top of sediment. The rod was then pushed to refusal to identify sediment thickness at that particular location. The difference between the top and bottom of sediment is assumed to be the soft sediment or muck thickness. This data is presented as transects shown on Figures 4 through 6.
4.0 SEDIMENT LOCATION AND THICKNESS
A soft sediment thickness map of the project area is shown on Figure 7 as defined by the bathymetric probing and muck sampling. The muck thickness throughout the IRL Area 1A predominantly ranged from approximately 0.25 to 2.5 feet. Deeper muck sediments, ranging between 5 and 11 feet in thickness, were identified along the southern boundary of the sampling area.
5.0 SEDIMENT CLASSIFICATION TESTS
Selected sediment samples collected from the piston tube sampling were tested for index parameters to determine sediment composition and assist with soil classification. The tests included the following:
• Natural moisture content (ASTM D 2216)
• Mechanical gradation (ASTM D 422)
• Percent passing a No. 200 sieve by wet wash method (ASTM D 1140)
• Atterberg Limit Tests (ASTM D 4318)
• Organic Content (ASTM D 2974)
Test results are summarized on the piston tube logs in Appendix B. Mechanical gradation results and atterberg limit test results are provided in Appendix C. Table 2 shows a summary of laboratory test data.
Muck Characterization Report Page 8
TABLE 2 Laboratory Summary Table
Boring No.
Depth Range)(1)
(bgs
Solids Content
Moisture Content(2)
% Finer #200 Sieve
Atterberg Limit Organic Content
(%) LL PL PI
A1A-07 0-6" 72.7 37.5 16.0 - - - -
A1A-08 0-20" 43.0 132.4 47.3 - - - -
A1A-08 20-42" 44.2 126.0 43.9 - - - -
A1A-08 42-66" 39.0 156.5 88.2 - - - -
A1A-12 0-6" 59.5 68.2 39.5 - - - -
A1A-14 0-12" 63.3 58.0 32.2 - NP NP -
A1A-17 0-48" 51.3 94.8 42.0 - - - 5.4
A1A-17 48-96" 49.4 102.6 57.5 - - - -
A1A-17 96-132" 50.8 96.7 82.6 53 40 13 -
A1A-18 0-78" 42.2 137.2 60.4 - - - -
A1A-23 0-12" 56.8 76.0 37.2 - - - 4.1
A1A-25 0-6" 52.4 90.8 32.1 - - - 5.1
A1A-27 30-60" 28.7 248.0 98.9 51 31 20 12.4
A1A-27 60-102" 40.8 145.2 94.1 - - - -
A1A-28 0-30" 70.4 42.1 15.7 - - - -
A1A-33 0-6" 62.7 59.6 25.4 - - - 4.8
A1A-35 0-12" 66.8 49.7 17.6 - - - -
A1A-36 0-48" 29.0 245.4 92.1 - - - -
A1A-36 48-96" 26.4 278.1 96.4 - - - -
A1A-36 96-114" 39.7 152.1 89.4 - - - 10.1
A1A-37 0-30" 32.8 204.5 25.0 - - - 10.2
A1A-37 30-60" 40.7 146.0 89.7 48 28 20 -
A1A-37 60-90" 55.9 79.0 45.3 - - - -
A1A-45 0-24" 30.0 232.8 84.4 53 29 24 -
A1A-45 24-48" 36.6 172.9 95.4 - - - -
A1A-45 48-78" 57.0 75.4 58.7 - - - -
A1A-46 0-3" 60.4 65.7 37.9 - - - -
A1A-53 0-36" 52.8 89.4 32.1 - - - 3.3
A1A-53 36-72" 36.5 174.1 90.1 54 30 24 -
A1A-53 72-84" 55.0 81.9 49.6 - - - 3.5
A1A-54 0-6" 68.0 47.1 19.7 - - - -
Note (1): Depth below top of sediment Note (2): Moisture Content is a ratio of Mass of Water over Mass Dry Sample per ASTM D 2216
Muck Characterization Report Page 9
5.1 Column Settling Tests
Column settling tests are typically performed on marine sediments to be dredged in an effort to predict settling behavior subsequent to deposition in a containment area. The Department of the Army, U. S. Army Corps of Engineers (USACE), Engineer Manual (EM) No. 1110-2-5027, provides test procedures for conducting settling tests for evaluation of dredged material settling performance and development of dredged material containment area design criteria. The USACE procedures include use of an 8-inch diameter by 6-foot tall settling column or a smaller cylinder (minimum 4000 ml) for pilot scale studies.
As the dredge sediment disposal and muck treatment methods have not been specified at this stage of the project, pilot scale settling tests using a 4000 ml graduated glass cylinder were conducted to determine the settling characteristics of the muck. Water from Eau Gallie River and muck from multiple locations throughout the proposed dredge areas were mixed to an approximately 5% solids content slurry as the expected lower limit for dredged material discharged to a disposal area. The water clarity of the IRL prior to mixing with slurry was measured at 2 to 3 NTUs. No chemical additives (flocculants) were used during these settling tests to enhance the rates of settling and water clarification. The slurry was thoroughly mixed and then allowed to settle for a minimum time period of 15 days or until no further settlement or water clarity changes were observed. The height of solids and water clarity recorded in Nephelometric Turbidity Units (NTU) was measured at regular time intervals throughout the test.
The settling test results are summarized in Table 3 including initial and final solids content along with corresponding supernatant NTUs and specific gravity. Settling test measurements were recorded at periodic intervals during the test, as shown on the data tables in Appendix D.
These settling tests were terminated after a 15-day period corresponding to no changes in settlement or water clarity.
TABLE 3 4000 ml Column Settling Test Data Summary
Boring No.
Assumed Specific Gravity
Initial Solid Content (%)
Fines Content
Initial Turbidity
(NTU)
15-Day Turbidity
(NTU)
15-Day Solids
Content (%)
A1A-08 2.4 5.0 59.8 185 1.9 52.02
A1A-17 2.4 5.0 60.7 260 1.9 48.15
A1A-18 2.4 5.0 60.4 140 2.0 56.81
A1A-27 2.4 5.0 96.4 160 2.0 53.25
A1A-36 2.4 5.0 92.6 210 1.6 54.47
A1A-45 2.4 5.0 79.5 260 1.6 53.25
A1A-53 2.4 5.0 57.3 250 2.0 63.71
The 4000 ml settling test samples were selected from representative muck samples in each section of the project area as shown on Figure 2. The settling results are shown as a plot of total (composite) solids content versus time shown in Appendix D. In general, the test results show a highly active settling (discreet & flocculated) period over the initial 24 hours. Composite solids content typically increased from the initial 5% slurry to the final solids of 48% to 64% within 3 days. During settling, the coarse (sands and shell fragments) and fine (silt/clay and
Muck Characterization Report Page 10 organics) fractions segregated. The coarse fraction falls out of suspension rapidly while the fine fraction remains in suspension for a longer period of time. The solids content of the segregated fine fraction was estimated at 10% to 20% solids content with the coarse fraction estimated at 60% to 80% solids content, generally varying with the variations in fines content. The supernatant water clarity typically decreased from greater than 140 NTUs to less than 3 NTUs within 3 days.
6.0 SEDIMENT CHARACTERIZATION
Recovered soft sediment samples showed in-situ solids content values ranging from approximately 26% to 73% with corresponding % passing #200 sieve ranging from approximately 16% to 99%. The lower solids and higher fines content are indicative of higher muck (organic fines) contents. Organic contents on muck samples ranged between approximately 3% and 12%. Muck samples were tested for plasticity, a majority of the samples indicated a high plastic silt while some yielding non-plastic (NP) characteristics. The sediment test data shows a wide range of classification characteristics consistent with layering and mixing of natural sandy river sediments and organic muck throughout the IRL area.
In general, two layers of soft muck sediments were identified overlying sandy hard bottom. The layers were identified as dark grey organic silt with sand (USCS Classification ML/MH) and dark grey and brown silty sand with organics and shell fragments (USCS Classification SM). The sediment stratification is shown on the muck thickness cross sections in Figures 4 through 6.
7.0 CLOSING AND LIMITATIONS
The piston tube sampler logs and survey point data represent the subsurface conditions at the specific location at the time of the exploration. The subsurface conditions at other locations may differ, and no warranty as to the subsurface conditions elsewhere is either expressed or implied by the data presented herein. Furthermore, the depths of the piston tube samplers, designating the interface between the various soils, are only approximate boundaries where the transition is gradual or could not be detected by the sampling geologist. In addition, the water and sediment elevation is only indicative of the conditions at the time of the investigation as water and sediment levels may fluctuate significantly because of various factors.
Muck Characterization Report Page 11
8.0 REFERENCES
AMEC Environment & Infrastructure, Inc., "Revised Report of Preliminary Geotechnical Exploration Washington Park DMMA”, March 2015.
Amec Foster Wheeler Environment & Infrastructure, Inc., “Eau Gallie River and Elbow Creek Dredging Project,” August 2015
Amec Foster Wheeler Environment & Infrastructure, Inc., “Eau Gallie River Channel Area Geotechnical Data Report,” May 2017
Brown, D. et.al. Water Resources of Brevard County, Florida – Report of Investigations No. 28 - Florida Geological Survey (FGS), 1962 (p. 15 Table 2).
Florida Department of Environmental Protection-Florida Geological Survey lithologic database and USGS Paper 517 - Artesian Water in Tertiary Limestone in the Southeastern States (1966) V.T. Springfield.
Paulic, M., Steward, J., Busby, T., and Policastro, M., “Indian River Lagoon Basin Management Action Plans (BMAPS) Muck removal Project Credit Guidance”, Florida Department of Environmental Protection”, September 2012.
Steward, J. et al., “Indian River Lagoon (IRL) Basin Management Action Plans (BMAPS) Muck Project Survey Guidance-Draft”, September 2012.
Taylor Engineering, “Phase I Physical Survey and Muck Dredging Feasibility Study - Eau Gallie River and Elbow Creek” September 2013.
United States Department of Agriculture-National Resource Conservation Service (USDA- NRCS), Soil Survey of Brevard County, 2013.
FIGURE 1 Site Location Map – Area 1A
FIGURE 2 Transects & Sample Locations – Area 1A
FIGURE 3 Bathymetric Survey Location Plan – Area 1A
FIGURE 4 Muck Thickness Cross Sections (1 of 3) – Area 1A
FIGURE 5 Muck Thickness Cross Sections (2 of 3) – Area 1A
FIGURE 6 Muck Thickness Cross Sections (3 of 3) – Area 1A
FIGURE 7 Muck Thickness Map – Area 1A
Figures
AREA 3
146 ACRES
SAMPLED APRIL 2017
AREA 2
125 ACRES
AREA 1
174 ACRES
AREA 4
114 ACRES
EAU GALLIE
RIVER
AREA 1A
152 ACRES
SOURCE: USGS EARTHSTART GEOGRAPHICS (2017-MICROSOFT CORP)
1101 Channelside Dr., Ste #200 Tampa, FL 33602
Phone: 1.813.289.0750 Fax: 1.813.289.5474 www.amecfw.com CA-5392
Amec Foster Wheeler
Environment & Infrastructure, Inc.
P R
O J E
C T
N
U M
B E
R
X
C
I T
Y
T
A M
P A
Z G e o t e c h
P r o j e c t s X
T a y l o r B r e v a r d
E a u
G a l l i e
R i v e r D r a w i n g s C
A D
A r e a A x E
A U
G a l l i e A r e a A
T r a n s e c t s C
P d w g
L A
Y O
U T
F
I G
U R
E
S
V
E D
M
P
O
T S
T Y
L E
T A
B L E
C
I V
I L M
A S
T E
R C
B
O
T T
E D
D
R A
W
Y
V
I V
E S
M
A R
T I N
REVISED BY:DATE: DRAWN BY: PROJECT NO.:7/25/2017 SCALE:
AS_SHOWN
FIGURE 1
BREVARD COUNTY
SITE LOCATION MAP - AREA 1A
INDIAN RIVER LAGOON DREDING EVALUATION
MELBOURNE, FLORIDA
N.DEPIN
N
W E
S
SCALE IN FEET
0 1200'
LEGEND
SURVEY EXTENT
ICWW CHANNEL
300903X6M.VIVES
A1A-30
A1A-05
A1A-03
A1A-04
A1A-02
A1A-01
A1A-06
A1A-09
A1A-10
A1A-11
A1A-13
A1A-14
A1A-15
A1A-16
A1A-17
A1A-19
A1A-20
A1A-21
A1A-23
A1A-24
A1A-25
A1A-27
A1A-32
A1A-33
A1A-34
A1A-35
A1A-36
A1A-37
A1A-38
A1A-39
A1A-41
A1A-42
A1A-43
A1A-44
A1A-45
A1A-46
A1A-47
A1A-49
A1A-50
A1A-51
A1A-52
A1A-53
A1A-54
A1A-12 A1A-22
A1A-31 A1A-40
A1A-48
A1A-06
A1A-09
A1A-10
A1A-11
A1A-13
A1A-15
A1A-16
A1A-19
A1A-20
A1A-21
A1A-22
A1A-24
A1A-31
A1A-32
A1A-34
A1A-38
A1A-39
A1A-40
A1A-41
A1A-42
A1A-43
A1A-44
A1A-47
A1A-48
A1A-49
A1A-50
A1A-51
A1A-52
A1A-01
A1A-05
A1A-02
A1A-03
A1A-04
A1A-26
A1A-29
A1A-26
A1A-29
A1A-30
A1A-28
A1A-07
A1A-08
A1A-18A1A-18
1101 Channelside Drive, Suite 200, Tampa, FL 33602
Phone: 1.813.289.0750 Fax: 1.813.289.5474 www.amecfw.com CA-5392
Amec Foster Wheeler
Environment & Infrastructure, Inc.
SCALE:
DATE:DRAWN BY:
CHECKED BY:
APPROVED BY:
PROJECT NO.
DESIGNED BY:
REVISIONSDATE
BREVARD COUNTY
TRANSECTS & SAMPLE LOCATIONS - AREA 1A
INDIAN RIVER LAGOON DREDING EVALUATION
MELBOURNE, FLORIDA
N. DEPIN
M. VIVES
N. DEPIN
M. KELLEY
AS SHOWN
300903X6
FIGURE 211/7/2017
PR
O
JE
CT
N U
M
BE
R:
3X
C
IT
Y:
T
AM
PA
Z:
\G eo te ch (3
0) \P ro je ct s\
X0
Ta yl or
-B re va rd
E au
G al lie R iv er
\D ra w in gs \C
AD
\A re a-
1A \3
3x 6_
EA
U
-G al lie _A re a-
1A _T ra ns ec ts
_C P.
dw g
L
AY
O U
T:
F
IG
U
RE
SA
VE
D:
1/
8/
0:
LO
TS
TY
LE
TA
BL
E:
C
IV
IL
-M
AS
TE
R.
CT
B
P
LO
TT
ED
: 1 1/
8/
0:
DR
AW
N
B Y:
V
IV
ES
, M
AR
TI
N
N
W E
S
SCALE IN FEET
0 400'
SOURCE: USGS EARTHSTART GEOGRAPHICS (2017-MICROSOFT CORP)
LEGEND
APPROXIMATE PROJECT AREA EXTENTS
ICWW CHANNEL (ESTIMATED BASED ON CHANNEL MARKERS)
APPROXIMATE LOCATION OF PISTON TUBES SAMPLES WITH SAMPLE RECOVERY
APPROXIMATE LOCATION OF PISTON TUBES SAMPLES WITH NO SAMPLE RECOVERY
SAMPLING TRANSECTS
AREA
1A
AREA 1A
EAST-WEST BASELINE
AREA 1A
NORTH-SOUTH BASELINE
1101 Channelside Drive, Suite 200, Tampa, FL 33602
Phone: 1.813.289.0750 Fax: 1.813.289.5474 www.amecfw.com CA-5392
Amec Foster Wheeler
Environment & Infrastructure, Inc.
SCALE:
DATE:DRAWN BY:
CHECKED BY:
APPROVED BY:
PROJECT NO.
DESIGNED BY:
REVISIONSDATE
BREVARD COUNTY
BATHYMETRIC SURVEY LOCATION PLAN - AREA 1A
INDIAN RIVER LAGOON DREDING EVALUATION
MELBOURNE, FLORIDA
N. DEPIN
M. VIVES
N. DEPIN
M. KELLEY
AS SHOWN
300903X6
FIGURE 39/29/2017
PR
O
JE
CT
N U
M
BE
R:
3X
C
IT
Y:
T
AM
PA
Z:
\G eo te ch (3
0) \P ro je ct s\
X0
Ta yl or
-B re va rd
E au
G al lie R iv er
\D ra w in gs \C
AD
\A re a-
1A \3
3x
EA
U
-G al lie _A re a
1A _B at hy m et ric .d w g
L
AY
O U
T:
F
IG
U
D:
/2
9/
2:
TS
TY
LE
TA
BL
E:
C
IV
IL
-M
AS
TE
R.
CT
B
P
LO
TT
ED
: 1 1/
7/
:1
PM
N B
Y:
V
IV
ES
, M
AR
TI
N
N
W E
S
SCALE IN FEET
0 400'
SOURCE: USGS EARTHSTART GEOGRAPHICS (2017-MICROSOFT CORP)
LEGEND
BATHYMETRIC SURVEY POINT
AREA 1A
E V
A T
I O
N
N
A V
D f t
E
A S
T W
E S
T
B
A S
E L I N
E
E L
E V
A T
I O
N
N
A V
G f t
TRANSECT 3
-25
-20
-15
-10
-5
-25
-20
-15
-10
-5
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 11000-50-100-150-200-250-300-350-400-450-500-550-600-650-700-750-800-850-900-950-1000-1050-1100
E L E
V A
T I O
N
N
A V
D f t
E
A S
T W
E S
T
B
A S
E L I N
E
E L E
V A
T I O
N
N
A V
G f t
TRANSECT 1
-25
-20
-15
-10
-5
-25
-20
-15
-10
-5
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 11500-50-100-150-200-250-300-350-400-450-500-550-600-650-700-750-800-850-900-950-1000-1050-1100-1150
E L
E V
A T
I O
N
N
A V
D f t
E
A S
T W
E S
T
B
A S
E L I N
E
E L E
V A
T I O
N
N
A V
G f t
TRANSECT 2
-25
-20
-15
-10
-5
-25
-20
-15
-10
-5
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 11500-50-100-150-200-250-300-350-400-450-500-550-600-650-700-750-800-850-900-950-1000-1050-1100-1150-1200
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
1101 Channelside Drive, Suite 200, Tampa, FL 33602
Phone: 1.813.289.0750 Fax: 1.813.289.5474 www.amecfw.com CA-5392
Amec Foster Wheeler
Environment & Infrastructure, Inc.
SCALE:
DATE:DRAWN BY:
CHECKED BY:
APPROVED BY:
PROJECT NO.
DESIGNED BY:REVISIONSDATE
BREVARD COUNTY
MUCK THICKNESS CROSS SECTIONS (1 OF 3) - AREA 1A
INDIAN RIVER LAGOON DREDING EVALUATION
MELBOURNE, FLORIDA
N. DEPIN
M. VIVES
N. DEPIN
M. KELLEY
AS SHOWN
300903X6
FIGURE 411/7/2017
PR
O
JE
CT
N U
M
BE
R:
3X
C
IT
Y:
T
AM
PA
Z:
\G eo te ch (3
0) \P ro je ct s\
X0
Ta yl or
-B re va rd
E au
G al lie R iv er
\D ra w in gs \C
AD
\A re a-
1A \3
3x 6_
EA
U
-G al lie _A re a-
1A _T ra ns ec ts
.d w g L
AY
O
U T:
F
IG
U
D:
1/ 8/
2:
TS
TY
LE
TA
BL
E:
C
IV
IL
-M
AS
TE
R.
CT
B P
LO
TT
ED
: 1
1/ 8/
2:
N B
Y:
V
IV
ES
, M
AR
TI
N
LEGEND
SEDIMENT THICKNESS
SURVEYED TOP OF SEDIMENT
SURVEYED BOTTOM SOFT OF SEDIMENT
DARK GREY ORGANIC SILT WITH SAND (ML, MH)
TOP
BOTTOM
TOP PROBE LOCATION
BOTTOM PROBE LOCATION
DARK GREY AND BROWN SILTY SAND WITH
ORGANICS (SM) WITH OCCASIONAL
" TO
SHELL FRAGMENTS
SOUTH BOUNDARYNORTH BOUNDARY
NORTH BOUNDARY
NORTH BOUNDARY
SOUTH BOUNDARY
SOUTH BOUNDARY
E V
A T
I O
N
N
A V
D f t
E
A S
T W
E S
T
B
A S
E L
I N
E
E L
E V
A T
I O
N
N
A V
G f t
TRANSECT 4
-25
-20
-15
-10
-5
-25
-20
-15
-10
-5
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 11000-50-100-150-200-250-300-350-400-450-500-550-600-650-700-750-800-850-900-950
E L
E V
A T
I O
N
N
A V
D f t
E
A S
T W
E S
T
B
A S
E L
I N
E
E L
E V
A T
I O
N
N
A V
G f t
TRANSECT 5
-25
-20
-15
-10
-5
-25
-20
-15
-10
-5
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 11000-50-100-150-200-250-300-350-400-450-500-550-600-650-700-750-800
E L
E V
A T
I O
N
N
A V
D f t
E
A S
T W
E S
T
B
A S
E L
I N
E
E L
E V
A T
I O
N
N
A V
G f t
TRANSECT 6
-25
-20
-15
-10
-5
-25
-20
-15
-10
-5
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 11000-50-100-150-200-250-300-350-400-450-500-550-600-650-700
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
1101 Channelside Drive, Suite 200, Tampa, FL 33602
Phone: 1.813.289.0750 Fax: 1.813.289.5474 www.amecfw.com CA-5392
Amec Foster Wheeler
Environment & Infrastructure, Inc.
SCALE:
DATE:DRAWN BY:
CHECKED BY:
APPROVED BY:
PROJECT NO.
DESIGNED BY:REVISIONSDATE
BREVARD COUNTY
MUCK THICKNESS CROSS SECTIONS (2 OF 3) - AREA 1A
INDIAN RIVER LAGOON DREDING EVALUATION
MELBOURNE, FLORIDA
N. DEPIN
M. VIVES
N. DEPIN
M. KELLEY
AS SHOWN
300903X6
FIGURE 511/7/2017
PR
O
JE
CT
N U
M
BE
R:
3X
C
IT
Y:
T
AM
PA
Z:
\G eo te ch (3
0) \P ro je ct s\
X0
Ta yl or
-B re va rd
E au
G al lie R iv er
\D ra w in gs \C
AD
\A re a-
1A \3
3x 6_
EA
U
-G al lie _A re a-
1A _T ra ns ec ts
.d w g L
AY
O
U T:
F
IG
U
D:
1/ 8/
2:
TS
TY
LE
TA
BL
E:
C
IV
IL
-M
AS
TE
R.
CT
B P
LO
TT
ED
: 1
1/ 8/
2:
N B
Y:
V
IV
ES
, M
AR
TI
N
2 2
LEGEND
SEDIMENT THICKNESS
SURVEYED TOP OF SEDIMENT
SURVEYED BOTTOM SOFT OF SEDIMENT
DARK GREY ORGANIC SILT WITH SAND (ML, MH)
TOP
BOTTOM
TOP PROBE LOCATION
BOTTOM PROBE LOCATION
DARK GREY AND BROWN SILTY SAND WITH
ORGANICS (SM) WITH OCCASIONAL
" TO
SHELL FRAGMENTS
NORTH BOUNDARY
NORTH BOUNDARY
NORTH BOUNDARY SOUTH BOUNDARY
SOUTH BOUNDARY
SOUTH BOUNDARY
E
V A
T I O
N
N
A V
D f t
E
A S
T W
E S
T
B
A S
E L I N
E
E L E
V A
T I O
N
N
A V
G f t
TRANSECT 9
-25
-20
-15
-10
-5
-25
-20
-15
-10
-5
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250 1300 1350 14000-50-100-150-200-250-300-350-400-450-500-550-600-650-700-750-800-850-900-950-1000-1050-1100-1150-1200-1250-1300-1350-1400-1450-1500
E L E
V A
T I O
N
N
A V
D f t
E
A S
T W
E S
T
B
A S
E L I N
E
E L E
V A
T I O
N
N
A V
G f t
TRANSECT 7
-25
-20
-15
-10
-5
-25
-20
-15
-10
-5
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250 1300 1350 14000-50-100-150-200-250-300-350-400-450-500-550-600-650-700-750-800-850-900-950-1000-1050-1100-1150-1200-1250-1300-1350-1400-1450-1500
E L E
V A
T I O
N
N
A V
D f t
E
A S
T W
E S
T
B
A S
E L I N
E
E L E
V A
T I O
N
N
A V
G f t
TRANSECT 8
-25
-20
-15
-10
-5
-25
-20
-15
-10
-5
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250 1300 1350 14000-50-100-150-200-250-300-350-400-450-500-550-600-650-700-750-800-850-900-950-1000-1050-1100-1150-1200-1250-1300-1350-1400-1450-1500
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
1101 Channelside Drive, Suite 200, Tampa, FL 33602
Phone: 1.813.289.0750 Fax: 1.813.289.5474 www.amecfw.com CA-5392
Amec Foster Wheeler
Environment & Infrastructure, Inc.
SCALE:
DATE:DRAWN BY:
CHECKED BY:
APPROVED BY:
PROJECT NO.
DESIGNED BY:REVISIONSDATE
BREVARD COUNTY
MUCK THICKNESS CROSS SECTIONS (3 OF 3) - AREA 1A
INDIAN RIVER LAGOON DREDING EVALUATION
MELBOURNE, FLORIDA
N. DEPIN
M. VIVES
N. DEPIN
M. KELLEY
AS SHOWN
300903X6
FIGURE 611/7/2017
PR
O
JE
CT
N U
M
BE
R:
3X
C
IT
Y:
T
AM
PA
Z:
\G eo te ch (3
0) \P ro je ct s\
X0
Ta yl or
-B re va rd
E au
G al lie R iv er
\D ra w in gs \C
AD
\A re a-
1A \3
3x 6_
EA
U
-G al lie _A re a-
1A _T ra ns ec ts
.d w g L
AY
O
U T:
F
IG
U
D:
1/ 8/
2:
TS
TY
LE
TA
BL
E:
C
IV
IL
-M
AS
TE
R.
CT
B P
LO
TT
ED
: 1
1/ 8/
2:
N B
Y:
V
IV
ES
, M
AR
TI
N
1 1
LEGEND
SEDIMENT THICKNESS
SURVEYED TOP OF SEDIMENT
SURVEYED BOTTOM SOFT OF SEDIMENT
DARK GREY ORGANIC SILT WITH SAND (ML, MH)
TOP
BOTTOM
TOP PROBE LOCATION
BOTTOM PROBE LOCATION
DARK GREY AND BROWN SILTY SAND WITH
ORGANICS (SM) WITH OCCASIONAL
" TO
SHELL FRAGMENTS
N
O R
T H
S
O U
H
S
E L I N
E
O R
T H
S
O U
S
E L I N
E
N
O R
T H
S
O U
S
E L I N
E
WEST BOUNDARY
WEST BOUNDARY
WEST BOUNDARYEAST BOUNDARY
EAST BOUNDARY
EAST BOUNDARY
1101 Channelside Drive, Suite 200, Tampa, FL 33602
Phone: 1.813.289.0750 Fax: 1.813.289.5474 www.amecfw.com CA-5392
Amec Foster Wheeler
Environment & Infrastructure, Inc.
SCALE:
DATE:DRAWN BY:
CHECKED BY:
APPROVED BY:
PROJECT NO.
DESIGNED BY:
REVISIONSDATE
BREVARD COUNTY
MUCK THICKNESS MAP - AREA 1A
INDIAN RIVER LAGOON DREDING EVALUATION
MELBOURNE, FLORIDA
N. DEPIN
M. VIVES
N. DEPIN
M. KELLEY
AS SHOWN
300903X6
FIGURE 711/7/2017
PR
O
JE
CT
N U
M
BE
R:
3X
C
IT
Y:
T
AM
PA
Z:
\G eo te ch (3
0) \P ro je ct s\
X0
Ta yl or
-B re va rd
E au
G al lie R iv er
\D ra w in gs \C
AD
\A re a-
1A \3
3x
EA
U
-G al lie _A re a
1A _S ou nd in g
Su rf ac es
.d w g L
AY
O
U T:
F
IG
U
D:
1/ 7/
:3
TS
TY
LE
TA
BL
E:
C
IV
IL
-M
AS
TE
R.
CT
B
P
LO
TT
ED
: 1 1/
7/
:4
N B
Y:
V
IV
ES
, M
AR
TI
N
N
W E
S
SCALE IN FEET
0 400'
SOURCE: USGS EARTHSTART GEOGRAPHICS (2017-MICROSOFT CORP)
LEGEND
0.0' ~ 0.5'
0.5' ~ 1.0'
MUCK THICKNESSMUCK THICKNESS
1.0' ~ 1.5'
1.5' ~ 2.0'
2.0' ~ 2.5'
2.5' ~ 3.0'
3.0' ~ 3.5'
3.5' ~ 4.0'
4.0' ~ 4.5'
4.5' ~ 5.0'
6.5' ~ 7.0'
5.0' ~ 5.5'
5.5' ~ 6.0'
6.0' ~ 6.5'
7.0' ~ 7.5'
7.5' ~ 8.0'
8.0' ~ 8.5'
8.5' ~ 8.0'
9.0' ~ 9.5'
9.5' ~ 10.0'
10.0' +
APPENDIX A
Site Geology – Area 1A
Appendix A
APPENDIX8/23/2017
PR
O
JE
CT
N U
M
BE
R:
C
IT
Y:
T
AM
PA
Z:
\G eo te ch
(3
0)
\P ro je ct s\
X0
Ta yl or -B re va rd E au G al lie
R iv er \D ra w in gs
\C
AD
\A re a- 1A
\3
3x
6_
EA
U -G al lie
_A re a- 1A
_T ra ns ec ts _C
P.
dw g L
AY
O
U T:
A
PP
EN
DI
X S
AV
ED
: 8 /2
3/
1:
TS
TY
LE
TA
BL
E:
C
IV
IL
-M
AS
TE
R.
CT
B
P
LO
TT
ED
: 9 /2
8/
0:
N
B Y:
V
IV
ES
, M
AR
TI
N
1101 Channelside Drive, Suite 200, Tampa, FL 33602
Phone: 1.813.289.0750 Fax: 1.813.289.5474 www.amecfw.com CA-5392
Amec Foster Wheeler
Environment & Infrastructure, Inc.
SCALE:
DATE:DRAWN BY:
CHECKED BY:
APPROVED BY:
PROJECT NO.
DESIGNED BY:REVISIONSDATE
BREVARD COUNTY
SITE GEOLOGY - AREA 1A
INDIAN RIVER LAGOON DREDING EVALUATION
MELBOURNE, FLORIDA
N. DEPIN
M. VIVES
N. DEPIN
M. KELLEY
AS SHOWN
300903X6
APPENDIX B
Piston Tube Sampling Logs
Appendix B
BK
-14.6
-15.1SM
14.0 14.5 average water level (elev. -0.6ft) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
sampler refusal
Bottom of borehole at 14.5 feet.
MC = 38%
#200 = 18%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/22/17 COMPLETED 6/22/17
NOTES
LOCATION N1382121.651 , E779724.9517
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-07
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
MATERIAL DESCRIPTIONTESTS
BK
BK
-15.6
-21.1
SM
15.0
20.5 average water level (elev. -0.6ft) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
sampler refusal Bottom of borehole at 20.5 feet.
MC = 132%
#200 = 47%
MC = 126%
#200 = 45%
MC = 157%
#200 = 48%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/22/17 COMPLETED 6/22/17
NOTES
LOCATION N1381886.569 , E779810.0191
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-08
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
-11.6
-12.1SM
11.0 11.5 average water level (elev. -0.6ft) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
sampler refusal
Bottom of borehole at 11.5 feet.
MC = 68%
#200 = 40%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/26/17 COMPLETED 6/26/17
NOTES
LOCATION N1383467.195 , E779769.7783
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-12
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
-12.6
-13.6SM
12.0
13.0 average water level (elev. -0.6ft) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
sampler refusal
Bottom of borehole at 13.0 feet.
MC = 58%
#200 = 32%
LL = NP
PL = NP
PI = NP
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/26/17 COMPLETED 6/26/17
NOTES
LOCATION N1382997.401 , E779940.9357
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-14
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
BK
BK
-12.6
-16.6
-23.6
SM
MH
12.0
16.0
23.0 average water level (elev. -0.6ft) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
very dark gray, organic, SILT with sand. (Munsell 10YR3/1) sampler refusal Bottom of borehole at 23.0 feet.
MC = 95%
#200 = 41%
OC = 5%
MC = 103%
#200 = 58%
MC = 97%
#200 = 83%
LL = 53
PL = 40
PI = 13
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/22/17 COMPLETED 6/22/17
NOTES
LOCATION N1382291.967 , E780195.6167
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-17
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
-13.6
-21.1
ML
13.0
20.5 average water level (elev. -0.6ft) very dark gray, organic, SILT with sand. (Munsell 10YR3/1) sampler refusal Bottom of borehole at 20.5 feet.
MC = 137%
#200 = 60%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/22/17 COMPLETED 6/22/17
NOTES
LOCATION N1382056.885 , E780280.6842
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-18
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
-11.6
-12.6SM
11.0
12.0 average water level (elev. -0.6ft) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
sampler refusal
Bottom of borehole at 12.0 feet.
MC = 76%
#200 = 37%
OC = 4%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/27/17 COMPLETED 6/27/17
NOTES
LOCATION N1383167.166 , E780410.0771
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-23
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
-12.6
-13.1SM
12.0 12.5 average water level (elev. -0.6ft) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
sampler refusal
Bottom of borehole at 12.5 feet.
MC = 91%
#200 = 32%
OC = 5%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/26/17 COMPLETED 6/26/17
NOTES
LOCATION N1382697.002 , E780580.212
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-25
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
BK
BK
-13.1
-21.6
MH
12.5
21.0 average water level (elev. -0.6ft) very dark gray, organic, SILT with sand. (Munsell 10YR3/1) sampler refusal Bottom of borehole at 21.0 feet.
MC = 248%
#200 = 99%
LL = 51
PL = 31
PI = 20
OC = 12%
MC = 145%
#200 = 94%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/20/17 COMPLETED 6/20/17
NOTES
LOCATION N1382226.839 , E780750.347
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-27
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
-12.6
-15.1
SM
12.0
14.5 average water level (elev. -0.6ft) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
sampler refusal Bottom of borehole at 14.5 feet.
MC = 42%
#200 = 17%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/20/17 COMPLETED 6/20/17
NOTES
LOCATION N1381991.757 , E780835.4144
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-28
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
-11.6
-12.1SM
11.0 11.5 average water level (elev. -0.6ft) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
sampler refusal
Bottom of borehole at 11.5 feet.
MC = 60%
#200 = 25%
OC = 5%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/27/17 COMPLETED 6/27/17
NOTES
LOCATION N1383102.219 , E780965.3085
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-33
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
-11.6
-12.6SM
11.0
12.0 average water level (elev. -0.6ft) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
sampler refusal
Bottom of borehole at 12.0 feet.
MC = 50%
#200 = 18%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/27/17 COMPLETED 6/27/17
NOTES
LOCATION N1382632.055 , E781135.4434
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-35
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
BK
BK
-13.1
-22.6
ML
12.5
22.0 average water level (elev. -0.6ft) very dark gray, organic, SILT with sand. (Munsell 10YR3/1) sampler refusal Bottom of borehole at 22.0 feet.
MC = 245%
#200 = 92%
MC = 278%
#200 = 96%
MC = 152%
#200 = 89%
OC = 10%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/21/17 COMPLETED 6/21/17
NOTES
LOCATION N1382396.973 , E781220.5109
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-36
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
BK
BK
-13.1
-15.6
-18.1
-20.6
SM
MH
SM
12.5
15.0
17.5
20.0 average water level (elev. -0.6ft) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
very dark gray, organic, SILT with sand. (Munsell 10YR3/1) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
sampler refusal Bottom of borehole at 20.0 feet.
MC = 205%
#200 = 25%
OC = 10%
MC = 146%
#200 = 90%
LL = 48
PL = 28
PI = 20
MC = 79%
#200 = 45%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/20/17 COMPLETED 6/20/17
NOTES
LOCATION N1382162.017 , E781305.9243
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-37
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
BK
BK
-13.1
-19.6
MH
12.5
19.0 average water level (elev. -0.6ft) very dark gray, organic, SILT with sand. (Munsell 10YR3/1) sampler refusal Bottom of borehole at 19.0 feet.
MC = 233%
#200 = 84%
LL = 53
PL = 29
PI = 24
MC = 173%
#200 = 95%
MC = 75%
#200 = 59%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/20/17 COMPLETED 6/20/17
NOTES
LOCATION N1382332.026 , E781775.7423
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-45
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
-4.1
-4.4SM
3.5 3.8 average water level (elev. -0.6ft) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
sampler refusal
Bottom of borehole at 3.8 feet.
MC = 66%
#200 = 38%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/20/17 COMPLETED 6/20/17
NOTES
LOCATION N1382147.939 , E781842.3567
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-46
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
BK
BK
-13.1
-16.1
-19.1
-20.1
SM
MH
SM
12.5
15.5
18.5
19.5 average water level (elev. -0.6ft) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
very dark gray, organic, SILT with sand. (Munsell 10YR3/1) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
sampler refusal
Bottom of borehole at 19.5 feet.
MC = 89%
#200 = 32%
OC = 3%
MC = 174%
#200 = 90%
LL = 54
PL = 30
PI = 24
MC = 82%
#200 = 50%
OC = 4%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED BY ND
DATE STARTED 6/20/17 COMPLETED 6/20/17
NOTES
LOCATION N1382502.161 , E782245.9062
GROUND WATER LEVEL AT TIME OF DRILLING 0.00 ft / Elev -0.60 ft
HOLE COMPLETION
GROUND ELEVATION -0.6 ft HOLE SIZE 2 inches
D E
P T
H (f t)
S A
M P
LE
T
Y P
E N
U M
B E
R
BORING NUMBER A1A-53
PROJECT LOCATION Melbourne, Brevard County, Florida
PROJECT NAME Indian River Lagoon Dredge Evaluation
PROJECT NUMBER 300903x6
CLIENT Brevard County/ Taylor Engineering Inc.
U .S
.C .S
G R
A P
H
IC
LO
G
-4.4
-4.9SM
3.8 4.3 average water level (elev. -0.6ft) dark gray to brown, organic, SILTY SAND with 1/4 to 1/2 inch clam shells (Munsell
10YR3/1)
sampler refusal
Bottom of borehole at 4.3 feet.
MC = 47%
#200 = 20%
LOGGED BY DR
DRILLING METHOD Piston Tube Sampling
DRILLING CONTRACTOR Amec Foster Wheeler
CHECKED…