CR232410 Backup Exhibit B Interim Facility As Builts by Woodard Curran.pdf
PDF 4 MB Posted
- Solicitation number
- RFP27007069
- Issued by
- Providence County, Rhode Island
About this file
This is a set of as-built structural drawings and design specifications for a metal building serving as an interim PFAS (per- and polyfluoroalkyl substances) water treatment facility at the University of Rhode Island in Kingston, Rhode Island. The submittal, prepared by Woodard & Curran and Hart Engineering Corporation and dated March 25, 2024, documents the structural design and construction details for a VP Buildings metal building system with expandable end frames. The facility encompasses a building approximately 42 feet wide by 32 feet long with a ridge height of approximately 27 feet 9 inches, finished floor elevation at 100 feet 0 inches, and vertical clearances of approximately 23 feet 4 inches to 23 feet 7 inches depending on frame location. The structural system includes four primary frame lines with welded steel members, multiple diagonal bracing configurations, anchor rod details, secondary structural components, roofing and wall cladding systems, insulation specifications, and trim schedules. The design incorporates specific load criteria including wind speed of 138 mph (ultimate), ground snow load of 30 psf, seismic design category C, and rainfall intensity of 6 inches per hour for a Building Risk/Occupancy Category III hazardous/special occupancy classification per the 2018 International Building Code.
The structural design utilizes AISC ASD and AISI ASD code standards with detailed specifications for materials including hot-rolled shapes, cold-formed light-gauge shapes, and welded sections in various ASTM grades. Bolt connections employ A325 high-strength bolts with both snug-tight and pre-tension requirements depending on connection type and application. The roof system consists of 24-gauge SSR (Standing Seam Roof) metal panels in Galvalume finish with integrated insulation packages (9-inch and 6-inch thick ThermaLift fiberglass blankets with unfaced and polypropylene scrim kraft facings). Wall panels and roof liners are specified with complementary finishing systems and detailed trim schedules in Cool Dark Bronze and matching roof colors. The contractor and erector bear full responsibility for accurate workmanship, proper bracing during erection, field coordination with quality assurance agencies as required by the Authority Having Jurisdiction, field welding in accordance with AWS standards, and compliance with all OSHA and site safety requirements. VP Buildings retains proprietary rights to all drawings and specifications, which are provided solely for erection of this specific project and may not be reproduced or modified without written approval.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RFP Exhibit B – Interim facility as-builts by
Woodward & Curran
Hart Engineering Corporation SUBMITTAL:
133419-001
PROJECT: 5128. - Woodard & Curran URI PFAS Interim System Design-Build DATE: 03/25/2024
SUBMITTAL: 133419-001 - Metal Building
REVISION: 0
STATUS: Eng
SPEC #: 133419
TO: FROM:
Eric Axelrod Matthew Michael
WOODARD & CURRAN, INC. Hart Engineering Corporation
800 Scenic View Drive eaxelrod@woodardcurran.com
Cumberland, RI 02864
MMichael@hartcompanies.com
Item Revision Description Status Date Sent Date Returned
133419-001 0 Metal Building Eng 03/25/2024
Notes:
Certification Statement:
By this submittal, I hereby represent that I have determined and verified all field measurements, field construction criteria, materials, dimensions, catalog numbers and similar data, and I have checked and coordinated each item with other applicable approved shop drawings and all Contract requirements.
Additional Notes:
Status Codes
1-APP – No Exceptions Taken
2-ANR – Make Corrections Noted
3-R&R – Revise and Resubmit
4-REJ – Rejected
5-IPO – For Information Purposes Only
6-NRR – Not Required for Review
ENG – Submitted to Engineer
Sincerely, Hart Engineering Corporation
DATE: 03/25/2024
JOB #
LOCATION
CUSTOMER
BUILDER
PROJECT
BUILDERS PO#
FILENAME:
DATE
DRAWN / CHECK
PAGE
VP Buildings 3200 Players Club Circle Memphis TN 38125
VPC VERSION:
Codes and Loads
GRADE BA500HOLLOW STRUCTURAL SECTION (HSS)
Standard Erection Details
Special Drawings
Covering
Secondary Structural
Primary Structural
Anchor Rod Plan
Cover Sheet
PAGESDRAWING TITLE
DRAWING INDEX
DESCRIPTIONDATETYPE
DRAWING RELEASE HISTORY
HIGH STRENGTH BOLT TIGHTENING REQUIREMENTS
MATERIALS
GENERAL NOTES
ASTM DESIGNATION
GRADE 50 OR GRADE 80
GRADE 36 OR 50
GRADE 50
GRADE 60
GRADE 55A529, A572, A1011, A1018
A653, A1011
A572, A510
A36, A529, A572, A588, A992
A653, A792CLADDING
HOT ROLLED MILL SHAPES
BRACE RODS
COLD FORMED LIGHT GAGE SHAPES
3 PLATE WELDED SECTIONS
VARCO PRUDEN
VP BUILDINGS
GRADE 50A529, A572, A588, A992HOT ROLLED ANGLES
VP BUILDINGS
VARCO PRUDEN
a division of BlueScope Buildings North America, Inc.
a division of BlueScope Buildings North America, Inc.
R
REVERSALS ON CONNECTIONS.
IT IS THE RESPONSIBILITY OF THE ERECTOR TO ENSURE PROPER BOLT TIGHTNESS IN ACCORDANCE WITH APPLICABLE
REGULATIONS. SEE RCSC SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BOLTS FOR MORE INFORMATION.
SEE ERECTION GUIDE FOR BOLT TIGHTENING INSTRUCTIONS. THE FOLLOWING CRITERIA MAY BE USED TO DETERMINE
THE BOLT TIGHTNESS (I.E.-SNUG TIGHT OR PRE-TENSION) UNLESS REQUIRED OTHERWISE BY LOCAL JURISDICTION
OR CONTACT.
PRE-TENSION A325 BOLTS IF BUILDING SUPPORTS A CRANE GREATER THAN 5 TON CAPACITY.
PRE-TENSION A325 BOLTS IF BUILDING SUPPORTS MACHINERY THAT CREATES VIBRATION, IMPACT, OR STRESS
PRE-TENSION ANY CONNECTION WITH DESIGNATION A325-SC. SLIP CRITICAL (SC) CONNECTIONS MUST BE FREE OF PAINT, OIL, OR OTHER MATERIALS THAT REDUCE FRICTION AT CONTACT SURFACES. GALVANIZED OR LIGHTLY RUSTED SURFACES
IN CANADA ALL A325 AND A490 BOLTS SHALL BE "PRE-TENSIONED", EXCEPT FOR SECONDARY MEMBERS AND FLANGE
SECONDARY MEMBERS AND FLANGE BRACE CONNECTIONS ARE ALWAYS "SNUG TIGHTENED" UNLESS INDICATED OTHERWISE IN
ALL A490 BOLTS SHALL BE "PRE-TENSIONED". A325 BOLTS IN PRIMARY FRAMING AND BRACING CONNECTIONS MAY BE
" SNUG-TIGHT" EXCEPT AS FOLLOWS;
ARE ACCEPTABLE.
BRACES.
ERECTION DRAWING DETAILS.
PRE-TENSION A325 BOLTS IF LOCATED IN HIGH SEISMIC AREAS. FOR IBC BASED CODES; HIGH SEISMIC IS
DESIGN CATEGORY D, E OR F. SEE CODES AND LOADS SECTION BELOW FOR DETAILS.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS
PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY
OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS
PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY
OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN
THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO
PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS
PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY
OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN
THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO
PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND
DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP
ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF
ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY
DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP.
Planograph Details
Notes
B
INSPECTION AND TESTING
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT IS
PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY
OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN
THIS DRAWING, ALL APPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO
PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VP AND
DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP. THE VP
ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF
ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VP EXCEPT TO ANY
DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY VP.
SPECIAL INSPECTIONS AND TESTING REQUIRED BY AUTHORITY HAVING JURISDICTION (AHJ) DURING CONSTRUCTION AND/OR
STEEL FABRICATION IS THE RESPONSIBILITY OF THE OWNER OR OWNERS AUTHORIZED AGENT. WHEN REQUIRED, THE OWNER SHALL EMPLOY A QUALITY ASSURANCE AGENCY (QAA) APPROVED BY THE AHJ. THE BUILDER IS RESPONSIBLE TO COORDINATE
BETWEEN THE QAA FIRM AND BBNA FABRICATION FACILITIES. THE TYPE AND EXTENT OF SPECIAL INSPECTIONS AND NDT WELD TESTING MUST BE SPECIFICALLY STIPULATED IN CONTRACT DOCUMENTS OR BBNA WILL ASSUME SPECIAL INSPECTIONS
AND/OR NDT TESTING ARE WAIVED AS PERMITTED BY THE BUILDING CODE BASED ON BBNA FACILITIES IAS AC472
ACCREDITATION.
COVER SHEET
Nortech Construction Co
Kingston, Rhode Island
WTP
4/24/2023
WTP Exter RI - Expandable End Frame
24.1.0
12:26:243/21/2024
URI Interim PFAS Treatment Facility
Hart Engineering
APPROVAL SET 3/21/24 NOT FOR CONSTRUCTION
APPROVAL SET 3/21/24 NOT FOR CONSTRUCTION
Shape Snow Buildup
Surface Description X Location Y Location Magnitude WTP Roof: A Unbalanced Snow Load 1, Shifted Left : Roof: A 0.0 ft 14.4 ft 8.0 psf
0.0 ft 0.0 ft 8.0 psf
32.0 ft 0.0 ft 8.0 psf
32.0 ft 14.4 ft 8.0 psf
WTP Roof: B Unbalanced Snow Load 1, Shifted Right : Roof: B 0.0 ft 14.4 ft 8.0 psf
0.0 ft 0.0 ft 8.0 psf
32.0 ft 0.0 ft 8.0 psf
32.0 ft 14.4 ft 8.0 psf
1. The Snow Buildup loading shown is in addition to the flat or sloped roof snow.
2. The X and Y Location dimensions are from the point of origin of each surface.
WHEN MULTIPLE BUILDINGS ARE INVOLVED, SPECIFIC LOAD FACTORS FOR DIFFERING OCCUPANCIES, BUILDING DIMENSIONS, Codes and Loads
HEIGHTS, FRAMING SYSTEMS, ROOF SLOPES, ETC., MAY RESULT IN DIFFERENT LOAD APPLICATION FACTORS THAN INDICATED BELOW. SEE CALCULATIONS FOR FURTHER DETAILS. WIND LOADS ARE APPLIED TO OVERALL BUILDING ENVELOPE.
COMMON WALLS BETWEEN CONNECTED SHAPES ARE NOT SUBJECT TO EXTERNAL WIND LOADS.
City: Kingston County: Washington State: Rhode Island Country: United States
Building Code: 2018 International Building Code Building Code
Structural: 16AISC - ASD Rainfall: I: 6.00 inches per hour Building Risk/Occupancy Category: III (Hazardous / Special Occupancy) Cold Form: 16AISI - ASD f'c: 3000.00 psi Concrete
Collateral Gravity: 5.00 psf Dead and Collateral Loads
Collateral Uplift: 0.00 psf
Wind Load Wind Speed: Vult: 138.00 (Vasd: 106.89) mph The 'All Heights' Method is Used Primaries Wind Exposure: D - Kz: 1.134 Parts Wind Exposure Factor: 1.134 Wind Enclosure: Enclosed Topographic Factor: Kzt: 1.0000 Ground Elevation Factor: Ke: 1.0000
Windborne Debris Region Impact Resistant Covering Base Elevation: 0/0/0 Site Elevation: 0.0 ft Primary Zone Strip Width: 2a: 13/0/0 Parts / Portions Zone Strip Width:
Walls, a: 6/6/0 Roof(s), 0.6h: 15/7/3 Velocity Pressure: qz: 46.98, (C&C) 46.98 psf
Roof Covering + Second. Dead Load: 4.83 psf Material Dead Weight
Frame Weight (assumed for seismic):2.50 psf
Snow Load Ground Snow Load: pg: 30.00 psf Flat Roof Snow: pf: 25.41 psf Design Snow (Sloped): ps: 25.41 psf Rain Surcharge: 0.00 psf Specified Minimum Roof Snow: 25.41 psf (USR) Exposure Factor: 3 Sheltered - Ce: 1.00 Snow Importance: Is: 1.100 Thermal Factor: Kept just above freezing - Ct: 1.10 Ground / Roof Conversion: 0.70 Obstructed or Not Slippery
Roof Live Load: 20.00 psf Not Reducible Roof Live Load
Seismic Load Lateral Force Resisting Systems using Equivalent Force Procedure Mapped MCE Acceleration: Ss: 16.10 %g Mapped MCE Acceleration: S1: 5.80 %g Site Class: Soft soil (E) Seismic Importance: Ie: 1.250 Design Acceleration Parameter: Sds: 0.2576 Design Acceleration Parameter: Sd1: 0.1624 Seismic Design Category:: C Seismic Snow Load: 0.00 psf % Snow Used in Seismic: 0.00 Diaphragm Condition: Flexible Fundamental Period Height Used: 26/10/8
Transverse Direction Parameters System NOT detailed for Seismic Redundancy Factor: Rho: 1.00 Fundamental Period: Ta: 0.3896 R-Factor: 3.00 Overstrength Factor: Omega: 2.50 Deflection Amplification Factor: Cd: 3.00 Base Shear: V: 0.1073 x W
Longitudinal Direction Parameters System NOT detailed for Seismic Redundancy Factor: Rho: 1.00 Fundamental Period: Ta: 0.2361 R-Factor: 3.00 Overstrength Factor: Omega: 2.50 Deflection Amplification Factor: Cd: 3.00 Base Shear: V: 0.1073 x W
Roof: A
WTP
X
Y
Roof: B
WTP X
Y
VPC VERSION:
FILENAME:
JOB #
DATE
DRAWN/CHECK
PAGE
BUILDER
CUSTOMER
LOCATION
PROJECT
BUILDER'S PO#
DATEREV BY DESCRIPTION
VP BUILDINGS
VARCO PRUDEN
VP Buildings
3200 Players Club Circle Memphis TN 38125 a division of BlueScope Buildings North America, Inc.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE
GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS
ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,
INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE
GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS
ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,
INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THE VP ENGINEER'S SEAL APPLIES ONLY
TO THE WORK PRODUCT OF VP AND
DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP. THE
VP ENGINEER'S SEAL DOES NOT APPLY
TO THE PERFORMANCE OR DESIGN OF
ANY OTHER PRODUCT OR COMPONENT
FURNISHED BY VP EXCEPT TO ANY
DESIGN OR PERFORMANCE
REQUIREMENTS SPECIFIED BY VP.
B CODES AND LOADS
Nortech Construction Co
Kingston, Rhode Island
WTP
4/24/2023
WTP Exter RI - Expandable End Frame
24.1.0NTS
12:26:253/21/2024
URI Interim PFAS Treatment Facility
Hart Engineering5 3/21/24 HH APPROVAL SET
John Bull Woodard & Curran, Inc.
John Bull Woodard & Curran, Inc.
BUILDER/CONTRACTOR RESPONSIBILITIES
VP Buildings follows the guidelines as outlined in the AISC and MBMA Codes of Standard Practice.
PANELS
Oil canning is an inherent characteristic of cold formed steel panels. It is the result of several factors that include induced stresses in the raw material delivered to VP, fabrication methods, installation procedures, and post installation thermal forces. Thru fastened panels will exhibit some dimpling when installed, especially when insulation is installed between panels and secondary supports. Dimpling can be minimized by careful installation, taking care not to over drive fasteners.
springing back into place. All panels experience this action to some degree, especially with concealed clip Standing Seam panels. Roof rumble noise may be minimized by providing a layer of blanket insulation between the panels and any hard support surface such as steel secondary members, substrates such as plywood, steel decking, or rigid board insulation. A minimum of
3 inch thick blanket is recommended over steel secondary members, or 2 inch over substrates.
Oil canning, dimpling, and roof rumble do not affect the structural integrity or weather tightness of the panels and is not grounds for rejection of panels.
RAIN WATER RUNOFF
Drainage systems must be designed by the project professional to comply with code requirements.
VP is not responsible for drainage designs, overflow scuppers, down piping, etc. The project professional and contractor are responsible to ensure that primary drains and overflow devices such as scuppers and auxiliary drains are provided as required for the required rain intensity at
Roof rumble is a phenomenon that is caused by wind gusts lifting up on the roof panels and then the building perimeter and at valley conditions to prevent ponding.
However, it is imperative that installed Standing Seam panels be secured to the secondary The Standing Seam joint detail is designed with an interlocking feature for ease of installation.
structural members and properly seamed prior to departure from the job site each day.
SKYLIGHTS
Local building departments may require added fall restraint due to conditions that may affect the skylight structural integrity. It is the responsibility of the builder to determine and provide any added fall restraint under the skylight as may be required by your building department.
STEEL SHOP COAT
The purpose of VP's shop coat is to provide protection for the steel members during transportation, during temporary job site storage and during erection. Standard shop formulation is not designed to perform as a finish coat when exposed to environmental conditions. Members shall be kept free of the ground and properly drained during job site storage. It is the Builder's responsibility to ensure that if a finish coat is being applied over VP shop coat that the painting contractor verifies compatibility between his finish coat and VP's shop coat.
VP Buildings standard product specifications, design, fabrication, quality criteria shall govern all work unless stipulated otherwise in the contract documents. In case of discrepancies between VP Buildings structural plans and plans for other trades, VP Buildings structural plans shall govern.
It is the responsibility of the Builder to obtain approvals and permits from all governing agencies and jurisdictions as required. Approval of VP Buildings drawings constitutes the builders acceptance of VP interpretation of the contract purchase order. Unless specific design criteria concerning interface design and details are furnished as part of the contract, VP Buildings design assumptions shall govern.
CONSTRUCTION & ERECTION RESPONSIBILITY
The Builder is responsible for construction in strict accordance with VP Buildings "FOR CONSTRUCTION" drawings and all applicable product installation guides. VP is not responsible for work done from any other VP drawings that are not marked "FOR CONSTRUCTION", nor any drawings prepared by others.
As erected field assemblies of members shall be as specified in MBMA Code of Standard Practice
(in Canada - CSA S16), which require L/500 tolerance of installed members. Occasional field work including shimming, cutting, coping, and drilling for final fit-up are considered part of erection. Specified field work and field welding conditions indicated on these drawings shall also be included in the erectors scope of work. See Erection Guide for shimming procedure.
For building with top riding bridge cranes see Crane Data drawing for column plumb tolerance.
The building erector shall be properly licensed and experienced in erecting metal building systems.
The Builder is responsible for having knowledge of, and shall comply with, all OSHA requirements and all other governing site safety criteria. The builder is responsible for designing, supplying, locating and installing temporary supports and bracing during erection of the building. VP bracing is designed for code required loads after building completion and shall not be considered as adequate erection bracing. See Erection Guide.
EXISTING STRUCTURES
BRACING
Tension brace rods work in pairs to balance forces caused by initial tensioning. Care must be taken while tightening brace rods so as not to cause accidental or misalignment of components.
All rods must be installed loose and then tightened. Rods should not exhibit excessive sag. For long or heavy rods, or angles it may be necessary to support the rods at mid-bay by suspending them from secondary members.
Bracing for seismic or wind loading of objects or equipment that are not a part of the VP structure must be designed by a qualified professional to deliver lateral loads to primary frames and rod bracing struts. Equipment bracing and suspension connections must not impose torsion or minor axis loads, or cause local distortion in any VP components. VP accepts no responsibility for design or installation of bracing systems not furnished by VP.
FIELD WELDING
All field welding shall be done at the direction of a design professional, and done in accordance with governing requirements (AWS in USA, CWB in Canada) by welders qualified to perform the welding as directed by the applicable welding procedure specification (WPS). A WPS shall be prepared by the contractor for each welding variation specified. The contractor is responsible for any special welding inspection as required by local jurisdiction. Filler metal shall be
70 ksi (480 MPa) tensile strength. For welds in high seismic force resisting system (Seismic Cat D, E or F), minimum Charpy V-Notch toughness shall meet AISC-341 criteria
(20 ft-lbs min @ 0Deg F). Interpass temperatures shall not exceed 550Deg F (300Deg C).
DELIVERIES
It is the responsibility of the builder to have adequate equipment available at the job site to unload trucks in a safe and timely manner. The Builder will be responsible for all retention charges from carriers as a result of job site unloading delays.
Claims for damage or shorts MUST be noted on the Bill-of-Lading or delivery receipt and filed against the carrier by the consignee as per VP's Terms of Sales (F.O.B. Plant) under the Uniform Commercial Code. It is critical that damages or shorts be noted on the
Bill-of-Lading or you have little recourse with the carrier. Immediately upon delivery of material, material quantities are verified by the Builder against quantities billed on the shipping document.
Neither the Manufacturer nor the carrier is responsible for material shortages against quantities billed on the shipping document if such shortages are not noted on the shipping documents upon delivery of material and acknowledged by the carriers agent. For materials concealed in bundles, boxes, or crates, shortages must be reported immediately upon unpacking. Should products get wet, bundled and crated materials must be unpacked and unbundled immediately to provide drainage of trapped moisture. See Erection Guide for proper job site storage procedure.
SEALANTS
Sealants shall be applied in strict accordance with VP details or weather tightness will be compromised.
Sealant must be applied in temperatures and weather conditions consistent with labeling.
INDEPENDENT MEZZANINES
Independent mezzanines must be designed by a professional engineer. The engineer must ensure that proper isolation from the VP building has been provided to avoid structural damage due to differential movements, or inadvertently apply loads to the VP structure. VP accepts no responsibility for the design of the independent mezzanine.
FIRE CODE COMPLIANCE
It is the responsibility of the project design professional and builder to comply with local fire code regulations including consideration of, but not limited to, building use and occupancy, all building construction materials, separation requirements, egress requirements, fire protection systems, etc.
Builder shall advise VP of any special requirements to be furnished by VP.
FIELD MODIFICATIONS
Modifications to this building from details and instructions contained on these drawings must be approved in writing by VP Buildings engineers, or other licensed structural engineer. This includes, but is not limited to, removal of roof or wall cladding, removing or moving any flange braces or rod braces, cutting of openings for doors, windows or RTU's, correction of fabrication errors, etc.
The owner shall not impose loads to this structure beyond what is specified for this building in the contract documents. VP Buildings accepts no responsibility for the consequences of any unauthorized additions, alterations, or added loads to this structure.
If the builder intends to invoice VP Buildings for modifications in excess of $1000, The builder must notify VP Buildings immediately, and obtain a Work Authorization from VP Buildings prior to proceeding. All final claims must be submitted to VP Buildings with all supporting documentation within 30 days of the building completion. Claims submitted without work authorizations, or after
30 days will not be accepted. Correction of minor misfits, shimming and plumbing, moderate amount of reaming, drilling, chipping / cutting and minor welding are considered by Code of Standard Practice to be part of erection are not subject to claim reimbursement.
CONCRETE/MASONRY/CONVENTIONAL STUD WALLS
The engineer responsible for the design of the wall system is responsible for coordinating with, or specifying to VP Buildings, any wall to steel compatibility issues such as drift and deflection compatibility, special base details, and wall to VP steel connections. All fasteners, sealant and counter flashing of wall systems are to be provided by contractor. The engineer responsible for the wall shall design the anchorage to VP supporting elements consistent with Code required forces.
Dade Co. Product Approval (www.miamidade.gov/buildingcode)
Approved Products Listed Under Varco Pruden Buildings, Inc.
Underwriter's Laboratory Approvals (Available only when specified in contract)
SSR Roof-UL#TGKX-113; SSR Composite Roof Class 90-UL#TGKX-113A;
SSR Roof w/Super Block; Class 90-UL#TGKX-328;
Panel Rib Roof UL Class 60-UL#TGKX-60; Panel Rib Roof UL Class 90-UL#TGKX-64;
VP SLR II Roof Class 90-UL#TGKX-90, -180, -435, -435A, -176, -238, -238A, -238B
Factory Mutual Approved Assemblies (Available only when specified in contract)
SSR Roof Systems are approved in various type applications and listed in FM Approval Guide.
24 Ga SSR (0.0227" Nominal), is available in Class 1-60, 1-75, 1-90. 22Ga SSR (0.0277"
Nominal), is available in Class 1-75, 1-90-, 1-120.
ICC Evaluation Reports (www.icc-es.org)
SSR Roof System - #ESR-2527
SLR II Roof Systems are approved in various type applications and listed in FM Approval Guide.
24 Ga SLR II (0.0227" Nominal), is available in Class 1-75 and 1-120.
State of Florida Product Approvals (www.floridabuilding.org)
VP TextureClad - See Transamerican Structuroc, Inc.
VP TextureClad - See Transamerican Structuroc, Inc.
Approved Products Listed Under VP Buildings, Inc.
(www.cwbgroup.org)
Canadian CSA A660 Certifications
Listed under BlueScope Buildings North America, Inc.
IAS AC472 Approvals: (www.iasonline.org/services/metal-building-inspection)
Fabricator Approvals
Engineering Certifications of Authorization
VP BUILDINGS ACCREDITATIONS AND APPROVALS
City of Los Angeles, CA #FB00031; City of Houston, TX 767 & 429;
City of Phoenix, AZ C19-02008; Clark County, NV 43 & 833, San Bernardino County, CA 289
Listed under BlueScope Buildings North America, Inc.
Listed under Varco Pruden Buildings, a Division of BlueScope Buildings North America, Inc.
IAS AC472 Approvals: (www.iasonline.org/services/metal-building-inspection)
Design Approvals
SIGNAGE
The Builder is responsible for furnishing signs as required by Code and the Building Department, including but not limited to, exits, occupancy limits, floor loading limits, and bulk storage limits.
Floor loading signs shall clearly indicate maximum floor live load permitted.
Bulk storage facilities shall have signs clearly posted on all loaded walls indicating the type of commodity stored and the maximum storage height. Signs shall be clearly visible when building is fully loaded to design level. Overloading of floors or walls may result in failure.
State of Utah, City of Richmond, CA.
VP engineers are not Project Engineers or Engineer of Record for the overall project. VP engineering supply sealed engineering design data and drawings for VP supplied material as part of the overall project for use by others to obtain permits, approvals, and coordinate with other trades. All interface and/or compatibility of any materials not furnished by VP are to be considered and coordinated by the builder or A/E firm.
VP must be advised of any structure that is within 20 ft. of VP's building. Load effects from snow drifting, wind effects, and seismic separation must be considered for both the new and existing structures. VP has designed the new VP building for these effects. The owner/builder are responsible for employing a Professional Engineer to review and verify the existing structure for all load effects from the adjacent VP building.
Shimming of steel buildings during erection may be required to accomodate allowable tolerances during fabrication and erection. Special care should be taken by the building erector to shim connections where key dimensions must be maintained for building performance as even small tolerances can have a significant impact on critical dimensions such as height, clearances and plumbness, especially as the size of the member or building increases. Conditions where shimming should be expected can include but are not limited to large door openings, critical clear height requirements, cranes, buildings greater than 45 feet in height, clear spans greater than 125 feet and adjacent frames with different characteristics (like clear span frames adjacent to an endwall or modular frame). Shims are normally provided by the erector, but may be ordered upon request by contacting your Project Manager.
KS#E-29; KY#4490; LA#EF6722; MS#E-0592; MO#E-2010007736; NC#F-0998; ND#1579PE;
USA--AL#CA-5589-E; AZ#22225-0; AR#576; FL#30427; GA#PEF007551; ID#C-2470; IL#184-002649;
CAN--AB#P08900; NB#F0951; NL#D0044; NS#30123; NT#P062; ON#100148796; and YT#PP134
NJ#24GA28318800; NV#20437; OH#05898; OK#CA4170PE; RI#8838; SC#6206; SD#C-1787; TX#F4828;
VA#0411001520; VA#0411001518; WA#4119; WV#C03059-00
VPC VERSION:
FILENAME:
JOB #
DATE
DRAWN/CHECK
PAGE
BUILDER
CUSTOMER
LOCATION
PROJECT
BUILDER'S PO#
DATEREV BY DESCRIPTION
VP BUILDINGS
VARCO PRUDEN
VP Buildings
3200 Players Club Circle Memphis TN 38125 a division of BlueScope Buildings North America, Inc.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE
GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS
ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,
INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE
GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS
ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,
INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THE VP ENGINEER'S SEAL APPLIES ONLY
TO THE WORK PRODUCT OF VP AND
DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP. THE
VP ENGINEER'S SEAL DOES NOT APPLY
TO THE PERFORMANCE OR DESIGN OF
ANY OTHER PRODUCT OR COMPONENT
FURNISHED BY VP EXCEPT TO ANY
DESIGN OR PERFORMANCE
REQUIREMENTS SPECIFIED BY VP.
B ERECTION NOTES
Nortech Construction Co
Kingston, Rhode Island
WTP
4/24/2023
WTP Exter RI - Expandable End Frame
24.1.0NTS
12:26:263/21/2024
URI Interim PFAS Treatment Facility
Hart Engineering5 3/21/24 HH APPROVAL SET
1 1'-0"
Dimension Key
2 3'-4 1/2" J=8.50 3 4'-0"
1 1'-0"
Dimension Key
2 3'-4 1/2" J=8.50 3 4'-0"
'-0
32'-0"
'-0
'-0
7'-0"8'-0" J=8.50
'-0
'-0
'-7
/2
1 15'-0" 15'-0" 1
3 6'-4 1/2" J=8.50
5'-7 1/2"
AR2-1
AR2-1
AR3-1
AR1-1
AR1-1
AR2-1
AR2-1
AR3-1
ANCHOR ROD PLAN
Edge of Slab needs to be adjusted to accommodate th e 2 1/2" eWall Stanchion ledge
See Detail : TYPICAL COLUMN BASE PLATE DETAIL AT 2 1/2" LEDGE
A B L
B C B L
BL
2 3
BL
VPC VERSION:
FILENAME:
JOB #
DATE
DRAWN/CHECK
PAGE
BUILDER
CUSTOMER
LOCATION
PROJECT
BUILDER'S PO#
DATEREV BY DESCRIPTION
VP BUILDINGS
VARCO PRUDEN
VP Buildings
3200 Players Club Circle Memphis TN 38125 a division of BlueScope Buildings North America, Inc.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE
GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS
ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,
INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE
GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS
ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,
INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THE VP ENGINEER'S SEAL APPLIES ONLY
TO THE WORK PRODUCT OF VP AND
DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP. THE
VP ENGINEER'S SEAL DOES NOT APPLY
TO THE PERFORMANCE OR DESIGN OF
ANY OTHER PRODUCT OR COMPONENT
FURNISHED BY VP EXCEPT TO ANY
DESIGN OR PERFORMANCE
REQUIREMENTS SPECIFIED BY VP.
B ANCHOR ROD PLAN
Nortech Construction Co
Kingston, Rhode Island
WTP
4/24/2023
WTP Exter RI - Expandable End Frame
24.1.0NTS
<*> THE BUILDING IS DESIGNED WITH BRACING DIAGONALS IN THE DESIGNATED
BAYS. COLUMN BASE REACTIONS, BASE PLATES AND ANCHOR RODS ARE
AFFECTED BY THIS BRACING AND DIAGONALS MAY NOT BE RELOCATED
WITHOUT CONSULTING THE BUILDING SUPPLIERS ENGINEER.
Finished Floor Elevation = 100'-0" (Unless Noted Otherwise)
12:26:283/21/2024
AR1-1 (4)3/4" Dia.
Max Plate W=8",L=1'-4", Min Thk=3/8" Dim: A=1'-0" Elev.=101'-0"
AR2-1 (4)1" Dia.
Max Plate W=1'-0",L=1'-4", Min Thk=1/2" Dim: A=1'-0" Elev.=101'-0"
AR3-1 (4)3/4" Dia.
Max Plate W=10",L=1'-0", Min Thk=3/8" Dim: A=1'-0" Elev.=101'-0"
VPC VERSION:
FILENAME:
JOB #
DATE
DRAWN/CHECK
PAGE
BUILDER
CUSTOMER
LOCATION
PROJECT
BUILDER'S PO#
DATEREV BY DESCRIPTION
VP BUILDINGS
VARCO PRUDEN
VP Buildings
3200 Players Club Circle Memphis TN 38125 a division of BlueScope Buildings North America, Inc.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE
GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS
ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,
INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE
GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS
ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,
INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THE VP ENGINEER'S SEAL APPLIES ONLY
TO THE WORK PRODUCT OF VP AND
DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP. THE
VP ENGINEER'S SEAL DOES NOT APPLY
TO THE PERFORMANCE OR DESIGN OF
ANY OTHER PRODUCT OR COMPONENT
FURNISHED BY VP EXCEPT TO ANY
DESIGN OR PERFORMANCE
REQUIREMENTS SPECIFIED BY VP.
B ANCHOR ROD PLAN - DETAILS
Nortech Construction Co
Kingston, Rhode Island
WTP
4/24/2023
WTP Exter RI - Expandable End Frame
24.1.0NTS
12:26:293/21/2024
URI Interim PFAS Treatment Facility
Hart Engineering5 3/21/24 HH APPROVAL SET
John Bull Woodard & Curran, Inc.
1 1'-0"
Dimension Key
Part Bracing Part Schedule
Qty Length Detail
04RS2502 4 25'-2" BR01G2
04RS2409 4 24'-9" BR01G2
04RS2502
RS
04RS2409
RS
04RS2502
RS
04RS2409
RS
'-0
32'-0"
'-0
'-0
'-0
'-0
1 15'-0" 15'-0" 1
CX001
R B
X
R B
X
CX002
EPX001
CX003
R B
X
R B
X
CX003
CX004
R B
X
R B
X
CX005
EPX001
A B L
B C B L
BL
2 3
BL
PRIMARY AND ROOF BRACING PLAN
VPC VERSION:
FILENAME:
JOB #
DATE
DRAWN/CHECK
PAGE
BUILDER
CUSTOMER
LOCATION
PROJECT
BUILDER'S PO#
DATEREV BY DESCRIPTION
VP BUILDINGS
VARCO PRUDEN
VP Buildings
3200 Players Club Circle Memphis TN 38125 a division of BlueScope Buildings North America, Inc.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE
GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS
ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,
INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE
GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS
ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,
INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THE VP ENGINEER'S SEAL APPLIES ONLY
TO THE WORK PRODUCT OF VP AND
DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP. THE
VP ENGINEER'S SEAL DOES NOT APPLY
TO THE PERFORMANCE OR DESIGN OF
ANY OTHER PRODUCT OR COMPONENT
FURNISHED BY VP EXCEPT TO ANY
DESIGN OR PERFORMANCE
REQUIREMENTS SPECIFIED BY VP.
B PRIMARY AND ROOF BRACING PLAN
Nortech Construction Co
Kingston, Rhode Island
WTP
4/24/2023
WTP Exter RI - Expandable End Frame
24.1.0NTS
1. USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120)
W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS,
SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS,
UNLESS NOTED OTHERWISE.
2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME
SIDE OF THE WEB AS THE HILLSIDE WASHER.
Shape Name = WTP
12:26:303/21/2024
Part Frame Member Schedule
Mem Width Thick WebThk. Depth1 Depth2 Approx.Lgth Approx.Weight
CX001 1 10.0000 .3750 .1644 1'-3" 2'-6" 24'-6 7/16" 1062#
RBX001 2 6.0000 .5000 .1345 2'-0" 1'-0" 18'-0 1/16" 550#
RBX001 3 6.0000 .5000 .1345 1'-0" 2'-0" 18'-0 1/16" 550#
CX002 4 10.0000 .3750 .1644 1'-3" 2'-6" 24'-6 7/16" 1067#
EPX001 5 9.0000 .3750 .1345 11" 11" 24'-10 5/8" 709#
Id Bolt Connection & Plate Schedule
Qty Grade Bolt Bolt Plate Rows Rows PartNo Dia. Length Thick. Out In
A 16 A325 3/4" 2 1/2" 1/2" 4 4 0097284 B 6 A325 3/4" 2 1/2" 5/8" 1 2 0097284 C 4 A325 1/2" 1 1/2" - - - 49080
1 8 1/2"
Dimension Key
2 1'-0" 3 1'-6 11/16" 4 4 @ 2'-4 1/2" 5 2 @ 2'-7 9/16" 6 3'-6" 7 27'-9" Ridge Ht.
Horiz. Clearance between members 1(CX001) and 4(CX0 02): 35'-6 9/16" Frame Clearances
Vert. Clearance at member 1(CX001): 23'-4 1/8" Vert. Clearance at member 4(CX002): 23'-4 1/8" Finished Floor Elevation = 100'-0" (Unless Noted Ot herwise)
21'-0" 21'-0"
C
BL
A
BL
CL
B
42'-0"
FRAME CROSS SECTION AT FRAME LINE(S) 1
GC171120
GC175120
GC175120
GC175120
GC175120
GC175120
GC175120
GC171120
'-6
'-6
'-0
F F
C
F B
L C
F B
L C
E A
P
G F
B
G F
B
4' - 9"4
F B
L C
F B
L C
E A
P 2G F
B
G F
B
4' - 9" 4
GC175120
GC175120
GC175120
GC175120
GC175120
GC175120
GC175120
GC175120
'-6
'-6
'-0
21' - 0 7/ 8" 1. 0000: 12 21' - 0 7/ 8" 1. 0000: 12
C X
RBX001
RBX001
C X
E P
X
A
B
A
C
101'-0" 101'-0" 101'-0"
VPC VERSION:
FILENAME:
JOB #
DATE
DRAWN/CHECK
PAGE
BUILDER
CUSTOMER
LOCATION
PROJECT
BUILDER'S PO#
DATEREV BY DESCRIPTION
VP BUILDINGS
VARCO PRUDEN
VP Buildings
3200 Players Club Circle Memphis TN 38125 a division of BlueScope Buildings North America, Inc.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE
GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS
ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,
INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE
GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS
ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,
INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THE VP ENGINEER'S SEAL APPLIES ONLY
TO THE WORK PRODUCT OF VP AND
DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP. THE
VP ENGINEER'S SEAL DOES NOT APPLY
TO THE PERFORMANCE OR DESIGN OF
ANY OTHER PRODUCT OR COMPONENT
FURNISHED BY VP EXCEPT TO ANY
DESIGN OR PERFORMANCE
REQUIREMENTS SPECIFIED BY VP.
B FRAME CROSS SECTION AT FRAME LINE(S) 1
Nortech Construction Co
Kingston, Rhode Island
WTP
4/24/2023
WTP Exter RI - Expandable End Frame
24.1.0NTS
1. USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120)
W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS,
SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS,
UNLESS NOTED OTHERWISE.
2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME
SIDE OF THE WEB AS THE HILLSIDE WASHER.
Shape Name = WTP Wall 4, Frame 1
12:26:313/21/2024
Mem Width Thick WebThk. Depth1 Depth2 Approx.Lgth Approx.Weight
CX003 1 5.0000 .1875 .1644 1'-3" 2'-6" 22'-7 3/8" 475#
RBX002 2 5.0000 .2500 .1345 1'-11" 1'-0" 21'-0 5/8" 400#
RBX003 3 5.0000 .2500 .1345 1'-0" 1'-11" 21'-0 5/8" 399#
CX003 4 5.0000 .1875 .1644 1'-3" 2'-6" 22'-7 3/8" 475#
Id Bolt Connection & Plate Schedule
Qty Grade Bolt Bolt Plate Rows Rows PartNo Dia. Length Thick. Out In
A 6 A325 3/4" 2 1/2" 1/2" 1 2 0097284 B 6 A325 3/4" 2 1/2" 3/8" 1 2 0097284
1 8 1/2"
Dimension Key
2 1'-0" 3 1'-6 11/16" 4 4 @ 2'-4 1/2" 5 2 @ 2'-7 9/16" 6 3'-6" 7 27'-9" Ridge Ht.
Horiz. Clearance between members 1(CX003) and 4(CX0 03): 35'-7" Frame Clearances
Vert. Clearance at member 1(CX003): 23'-7 3/8" Vert. Clearance at member 4(CX003): 23'-7 3/8" Finished Floor Elevation = 100'-0" (Unless Noted Ot herwise)
C
BL
A
BL
42'-0"
FRAME CROSS SECTION AT FRAME LINE(S) 2
FBLC2
FBLC2
FBLC2
FBLC2
GFB2054
GFB2067
GFB2104
(2)GFB2104
'-6
'-6
'-0
E A
P
E S
B S
B
F B
L C
F B
L C
F B
L C
(2 )G
F B
G F
B
G F
B
4' - 9"4
E A
P
E S
B S
B
F B
L C
F B
L C
F B
L C
G F
B
G F
B
(2 )G
F B
4' - 9" 4
FBLC2
FBLC2
FBLC2
FBLC2
GFB2054
GFB2067
GFB2104
(2)GFB3097
'-6
'-6
'-0
21' - 0 7/ 8" 1. 0000: 12 21' - 0 7/ 8" 1. 0000: 12
C X
RBX002
RBX003
C X
A
B
A
101'-0" 101'-0"
VPC VERSION:
FILENAME:
JOB #
DATE
DRAWN/CHECK
PAGE
BUILDER
CUSTOMER
LOCATION
PROJECT
BUILDER'S PO#
DATEREV BY DESCRIPTION
VP BUILDINGS
VARCO PRUDEN
VP Buildings
3200 Players Club Circle Memphis TN 38125 a division of BlueScope Buildings North America, Inc.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE
GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS
ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,
INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE
GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS
ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,
INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THE VP ENGINEER'S SEAL APPLIES ONLY
TO THE WORK PRODUCT OF VP AND
DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY VP. THE
VP ENGINEER'S SEAL DOES NOT APPLY
TO THE PERFORMANCE OR DESIGN OF
ANY OTHER PRODUCT OR COMPONENT
FURNISHED BY VP EXCEPT TO ANY
DESIGN OR PERFORMANCE
REQUIREMENTS SPECIFIED BY VP.
B FRAME CROSS SECTION AT FRAME LINE(S) 2
Nortech Construction Co
Kingston, Rhode Island
WTP
4/24/2023
WTP Exter RI - Expandable End Frame
24.1.0NTS
1. USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120)
W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS,
SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS,
UNLESS NOTED OTHERWISE.
2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME
SIDE OF THE WEB AS THE HILLSIDE WASHER.
Shape Name = WTP Wall 4, Frame 2
12:26:333/21/2024
Mem Width Thick WebThk. Depth1 Depth2 Approx.Lgth Approx.Weight
CX004 1 10.0000 .3750 .1644 1'-3" 2'-6" 24'-6 7/16" 1068#
RBX001 2 6.0000 .5000 .1345 2'-0" 1'-0" 18'-0 1/16" 550#
RBX001 3 6.0000 .5000 .1345 1'-0" 2'-0" 18'-0 1/16" 550#
CX005 4 10.0000 .3750 .1644 1'-3" 2'-6" 24'-6 7/16" 1061#
EPX001 5 9.0000 .3750 .1345 11" 11" 24'-10 5/8" 709#
Id Bolt Connection & Plate Schedule
Qty Grade Bolt Bolt Plate Rows Rows PartNo Dia. Length Thick. Out In
A 16 A325 3/4" 2 1/2" 1/2" 4 4 0097284 B 6 A325 3/4" 2 1/2" 5/8" 1 2 0097284 C 4 A325 1/2" 1 1/2" - - - 49080
1 8 1/2"
Dimension Key
2 1'-0" 3 1'-6 11/16" 4 4 @ 2'-4 1/2" 5 2 @ 2'-7 9/16" 6 3'-6" 7 27'-9" Ridge Ht.
Horiz. Clearance between members 1(CX004) and 4(CX0 05): 35'-6 9/16" Frame Clearances
Vert. Clearance at member 1(CX004): 23'-4 1/8" Vert. Clearance at member 4(CX005): 23'-4 1/8" Finished Floor Elevation = 100'-0" (Unless Noted Ot herwise)
21'-0" 21'-0"
C
BL
A
BL
CL
B
42'-0"
FRAME CROSS SECTION AT FRAME LINE(S) 3
GC171120
GC175120
GC175120
GC175120
GC175120
GC175120
GC175120
GC171120
'-6
'-6
'-0
F F
C
F B
L C
F B
L C
E A
P
G F
B
G F
B
4' - 9"4
F B
L C
F B
L C
E A
P 2G F
B
G F
B
4' - 9" 4
GC175120
GC175120
GC175120
GC175120
GC175120
GC175120
GC175120
GC175120
'-6
'-6
'-0
21' - 0 7/ 8" 1. 0000: 12 21' - 0 7/ 8" 1. 0000: 12
C X
RBX001
RBX001
C X
E P
X
A
B
A
C
101'-0" 101'-0" 101'-0"
VPC VERSION:
FILENAME:
JOB #
DATE
DRAWN/CHECK
PAGE
BUILDER
CUSTOMER
LOCATION
PROJECT
BUILDER'S PO#
DATEREV BY DESCRIPTION
VP BUILDINGS
VARCO PRUDEN
VP Buildings
3200 Players Club Circle Memphis TN 38125 a division of BlueScope Buildings North America, Inc.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP BUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED
IN THE APPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT
PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE
GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGS
ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,
INCLUDING THE CORRECT USE OF TEMPORARY BRACING.
THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF
VP…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .