This file consists of 100% construction documents for the CNCC Yaeger Building Structural Stabilization and Repairs project, prepared by Rosenfeld Design, LLC for Colorado Northwestern Community College in Rangely, Colorado. The project involves repair of structural and waterproofing failures at the existing Yaeger Building located at 500 Kennedy Drive, Rangely, Colorado 81648, with work including minor site regrading. The construction documents, issued August 19, 2026, comprise architectural drawings (floor plans, exterior elevations, building sections, wall sections, and exterior details), structural drawings with framing details, civil engineering plans showing existing conditions, demolition requirements, and site grading, and a statement of special inspections. The project team includes Rosenfeld Design, LLC (architect), 3 Rocks Engineers (structural engineer), HCL Engineers (civil engineer), and True North Colorado LLC (surveyor). The existing building occupancy, construction type, location on property, floor area, and height remain unchanged. Work must be coordinated with building occupants as the facility remains in use during construction, and the general contractor is responsible for protecting all remaining finishes and equipment from damage.
The project applies 2021 IBC, IECC, and Colorado state code requirements. Special inspections are required in accordance with IBC Section 1704 and 1705, including structural observations, concrete and masonry construction monitoring, and testing as documented in the statement of special inspections included in the construction documents. The contractor must comply with all specifications regarding materials, dimensions, fire stops, shop drawings, and product submittals prior to commencing work. All construction and materials shall meet applicable codes, ordinances, and permit requirements. The contractor is responsible for accurate placement of new construction, complete building systems compliance with manufacturer requirements, proper sequencing and coordination among trades, and maintenance of a clean jobsite with prompt removal of debris. Weather resistive barrier details and products must be coordinated with manufacturers and the architect based on existing conditions, with approved substitutions potentially required.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
81 CRESCENT PLACE
GLENWOOD SPRINGS
COLORADO, 81601
rosenfeld-design.com
JOB NO.
SHEET NO.
TEL: 719.439.3335
ROSENFELD
D E S I G N
R
O S E N
F E
LD
D E S
IG
N
LL
C
C N
C C
Y A
E G
E R
B U
IL
D
IN
G
R A
N G
E
LY
C
O
LO
R A
D O
G100
COVER SHEET
YAEGER BUILDING
COLORADO NORTHWESTERN COMMUNITY COLLEGE
RANGELY, COLORADO
100% CONSTRUCTION DOCUMENTS - 8/19/26
ISSUE: DATE:
100% CDs 8/19/26
LOCATION
DRAWING INDEX
TN
SYMBOLS LEGEND
CAST
COMPACTED FILL
POROUS FILL
UNDISTURBED SOILS
CONCRETE BLOCK
BRICK
STONE
GLASS BLOCK
STEEL
MATERIALS LEGEND
EARTH
ROCK
CONCRETE
MASONRY
METAL
GROUT, LIGHTWEIGHT
CONCRETE
ABBREVIATIONS
AFF
BM
BS.
B.O.
ACCOUS
ADJ
ALT
ALUM
APPD
APPROX
ARCH
ASAP
BRG
BET
BLK
BSMT
BTU
BLDG
CAB
CLG
CER
CLR
ABOVE FINISHED FLOOR
ADJACENT
ALTERNATE
ALUMINUM
APPROXIMATE
APPROVED
BEAM
BEARING
BETWEEN
BLOCK
BASEMENT
BRITISH THERMAL UNIT(S)
BOARDBD
BOTH SIDES
BOTTOM OF
BUILDING
CABINET
CENTER LINE
CEILING
CERAMIC
CLEAR
CJ
CF
DP
DW
DN
DR
EA.
EW
CLO CLOSET
D
W
COL
CONC
CONT
COORD
CTR
DEPT
DTL
DIA,
DIM
DWG
ELECT
CLOTHES DRYER
CLOTHES WASHER
COLUMN
CONCRETE
CONSTRUCTION JOINT
CONTINUOUS
COORDINATE
COUNTER
CUBIC FEET
DAMPROOFING
DEPARTMENT
DETAIL
DIAMETER
DIMENSION
DOWN
DRAIN
DRAWING
EACH
EACH WAY
ELECTRICAL
EL
EQ
F.O.
FP
FD
FT
GA
GC
GL
GRD.
HD
HP
HT
ID
JT
ENGR
EXG
EXP.
EXT.
FIN
FIXT
FTG
FDN
FURN
GAL
GALV
GYP.
GWB
HDW
HVAC
HORIZ
HWH
INCL
INFO
INSUL
ELEVATION
ENGINEER
EQUAL
EXISTING
EXPOSED
EXTERIOR
FACE OF
FINISH
FIREPROOF
FIREPLACEFPL
FIXTURE
FLOOR
FLOOR DRAIN
FOOT, FEET
FOOTING
FOUNDATION
FURNISH
GALLON
GAUGE
GALVINIZED
GENERAL CONTRACTOR
GLASS, GLAZED
GRADE
GYPSUM
GYPSUM WALLBOARD
HARDWARE
HEAD
HORIZONTAL
HORSE POWER
HOT WATER HEATER
HEIGHT
INCLUDE (D) (ING)
INFORMATION
INSIDE DIAMETER
INSULATION
JOINT
INT INTERIOR
HEATING, VENTING, AND
AIR CONDITIONING
LT
MO
NA
OD
d
QT
R
RD
RM
JCT
KWH
LAV
MFR
MATL
MTL
MAX
MECH
MED
JUNCTION
KILOWATT HOUR
LAVATORY
LIGHT
MANUFACTURER
MATERIAL
MASONRY OPENING
METAL
MAXIMUM
MECHANICAL
MEDIC (INE) (AL)
MIN
MISC
NOM
NIC
NTS
OPG
OC
OPP
ORN
PTN
PERF PERFORATE(D)
PENNY (NAILS, ECT.)
MINIMUM
MISCELLANEOUS
NOMINAL
NOT IN CONTRACT
NOT APPLICABLE
NOT TO SCALE
ON CENTER
OPENING
OPPOSITE
ORNAMENTAL
OUTSIDE DIAMETER
PARTITION
PLT.
PLY
QTY
PLATE
PLYWOOD
QUARRY TILE
QUANTITY
RADIUS
ROOF DRAIN
ROOM
RS ROUGH SAWN
RW
R
RO
SQ
SS
TV
TO
T
UG
RCB
REF.
REFR
REINF
REBAR
REQD
SHT
SHLV
SVF
SIM
STC
SPEC
SF
RESILIENT COVE BASE
RETAINING WALL
REFER/REFERENCE
REFRIGERATOR
REINFORCE ( D)
REINFORCING BAR (S)
REQUIRED
RISER
ROUGH OPENING
SHEET
SHEET VINYL FLOORING
SHELV (ES) (ING)
SIMILAR
SOUND-TRANSMISSION CLASS
SPECIFICATION
SQUARE
SQUARE FEET
STD
STRUCT
SUB
SUPPL
S4S
SUSP
TEL
TEMP
T&G
T&B
TYP TYPICAL
STANDARD
STRUCTURAL
SUBSTITUTE
SUPPLEMENT
SURFACED FOUR SIDES
SUSPEND(ED)
TELEPHONE
TELEVISION
TOP AND BOTTOM
TONGUE AND GROOVE
TOP OF
TREAD
V
WH
WC
WP
WT
W/
WD
UNGL
UNFIN
VIF
VERT
VCT
WWF
WDW
W/O
UNGLAZED
UNFINISHED
VERIFY IN FIELD
VERTICAL
VOLT
WATER HEATER
WATER CLOSET
WATERPROOF
WEIGHT
WELDED WIRE FABRIC
WINDOW
WITH
WITHOUT
WOOD
ACOUSTICAL
ARCHITECT (URAL)
BFF BELOW FINISHED FLOOR
CL,
DISHWASHER
LAM LAMINATE (D)
OPH OPPOSITE HAND
STL STEEL
TEMPERED
AS SOON AS POSSIBLE
FLR
STAINLESS STEEL
VINYL COMPOSITION TILE
U.N.O. UNLESS NOTED OTHERWISE
UNDERGROUND
CL
IBC INTERNATIONAL BUILDING CODE
IRC INTERNATIONAL RESIDENTIAL
CODE
SPOT ELEVATION
NEW CONTOUR
EXISTING CONTOUR
CENTER LINE
HIDDEN LINE
SETBACK LINE
BREAK LINE
PROPERTY LINE
TOP OF PLATE
TOP OF FLOOR ELEVATION
EL.= 98.2
EL.=
T.O. PLATE
110'-0"
EL.=
T.O. PLY.
100'-0"
DETAIL NUMBER
SHEET NUMBER
SHEET NUMBER
SHEET NUMBER
BUILDING SECTION
WALL SECTION
ROOM NAME
ROOM NUMBER
REVISIONS
KEYNOTE
SHEET NUMBER
SHEET NUMBER
MATCH LINE
PROJECT NORTH
TRUE NORTH
INTERIOR ELEVATION
WINDOW NUMBER
EXTERIOR ELEVATION
A8.1
2A8.1
A
B
C
NORTH
A
3C
SEE SHEET
1 A2.1
D
KITCHEN
ROOM NUMBER
DOOR LETTER
CONSTRUCTION
ASSEMBLY
SHEET NUMBER
BATT
RIGID
INSULATION
SPRAYED FOAM
FINISH
WD. FRAMING
WD. BLOCKING
GLU-LAM
PLYWOOD
WOOD
BUILDING CLASSIFICATION / CODE INFORMATION
PROJECT DIRECTORY
2021 IBC, IECC AND ANY REQUIREMENTS BY THE STATE OF COLORADO
APPLICABLE CODES:
PROJECT INFORMATION
LOCATION: 500 KENNEDY DRIVE, RANGELY, COLORADO 81648
PROJECT DESCRIPTION: REPAIR STRUCTURAL AND WATERPROOFING FAILURES AT EXISTING
YAEGER BUILDING ON THE CNCC CAMPUS. REPAIR INCLUDES MINOR SITE REGRADING
GENERAL NOTES
ARCHITECT
ROSENFELD DESIGN, LLC
81 CRESCENT PLACE
GLENWOOD SPRINGS, CO 81601
719.439.3335
SURVEYOR
TRUE NORTH COLORADO LLC
PO BOX 614 - 386 MAIN STREET UNIT 3
NEW CASTLE, CO 81647
970.984.0474
STRUCTURAL ENGINEER
CIVIL ENGINEER
3 ROCKS ENGINEERS
430 MAIN STREET
CANON CITY, CO 81212
719.430.5333
HCL ENGINEERS
5975 S. QUEBEC STREET, SUITE 200
CENTENNIAL, CO 80111
303.773.1605
EXISTING OCCUPANCY TO REMAIN UNCHANGED
OCCUPANCY CLASSIFICATION:
EXISTING CONSTRUCTION TYPE TO REMAIN UNCHANGED
TYPE OF CONSTRUCTION:
EXISTING LOCATION TO REMAIN UNCHANGED
LOCATION ON PROPERTY:
EXISTING FLOOR AREA TO REMAIN UNCHANGED
ALLOWABLE FLOOR AREA:
EXISTING HEIGHT AND STORIES TO REMAIN UNCHANGED
HEIGHT AND NUMBER OF STORIES:
ALL CONSTRUCTION AND MATERIALS SHALL BE AS SPECIFIED AND IN ACCORDANCE
WITH ALL APPLICABLE CODES, ORDINANCES, LAWS, PERMITS, AND THE CONTRACT DOCUMENTS.
THE CONTRACTOR SHALL CONFINE HIS/HER OPERATIONS ON THE SITE TO AREAS
PERMITTED BY THE OWNER.
SHOULD A CONFLICT OCCUR IN OR BETWEEN DRAWINGS AND SPECIFICATIONS, THE
SPECIFICATIONS SHALL TAKE PRECEDENCE. UNLESS A WRITTEN DECISION FROM THE
ARCHITECT HAS BEEN OBTAINED WHICH DESCRIBES A CLARIFICATION OR ALTERNATE
METHOD AND/OR MATERIALS.
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE STARTING
WORK. SHOULD A DISCREPANCY APPEAR IN THE CONTRACT DOCUMENTS, OR BETWEEN THE
CONTRACT DOCUMENTS AND EXISTING CONDITIONS, NOTIFY THE ARCHITECT AT ONCE FOR
INSTRUCTION ON HOW TO PROCEED.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF ALL NEW
CONSTRUCTION ON THE SITE. THE CONTRACTOR SHALL PROVIDE COMPLETE BUILDING SYSTEMS
AND COMPONENTS IN COMPLIANCE WITH MANUFACTURERS' REQUIREMENTS AND
RECOMMENDATIONS. ALL SEQUENCING, INTERFACE AND COORDINATION WITH OTHER
BUILDING TRADES SHALL BE AS REQUIRED FOR COMPLETE, PROPERLY INSTALLED AND
OPERATING SYSTEMS AND/OR BUILDING COMPONENTS, AND SHALL MEET OR EXCEED
QUALITY LEVELS OF COMMONLY ACCEPTED CONSTRUCTION PRACTICE AND INDUSTRY
STANDARDS. CONTACT ARCHITECT WITH ANY QUESTIONS PRIOR TO STARTING WORK.
THE JOB SITE SHALL BE MAINTAINED IN A CLEAN, ORDERLY CONDITION, FREE OF DEBRIS
AND LITTER, AND SHALL NOT BE UNREASONABLY ENCUMBERED WITH ANY MATERIALS OR
EQUIPMENT. EACH SUB-CONTRACTOR IMMEDIATELY UPON COMPLETION OF EACH PHASE OF
HIS/HER WORK SHALL REMOVE ALL TRASH AND DEBRIS AS OF RESULT OF HIS/HER
OPERATION.
ALL MATERIALS STORED ON THE SITE SHALL BE PROPERLY STACKED AND PROTECTED
TO PREVENT DAMAGE AND DETERIORATION. FAILURE TO PROTECT MATERIALS MAY BE
CAUSE FOR REJECTION OF WORK.
WHERE LARGER STUDS OR FURRING ARE REQUIRED TO COVER PIPING AND CONDUITS,
THE LARGER STUD SIZE OR FURRING SHALL EXTEND THE FULL SURFACE OF THE WALL
WIDTH AND LENGTH WHERE THE FURRING OCCURS.
PROVIDE ALL ACCESS PANELS AS REQUIRED BY GOVERNING CODES TO ALL CONCEALED
SPACES, VOIDS, ATTICS, ECT. VERIFY TYPE REQUIRED WITH ARCHITECT PRIOR TO INSTALLATION.
THE CONTRACTOR SHALL DO ALL CUTTING, FITTING, OR PATCHING OF HIS/HER WORK THAT MAY
BE REQUIRED TO MAKE ITS SEVERAL PARTS FIT TOGETHER PROPERLY AND SHALL NOT
ENDANGER ANY OTHER WORK BY CUTTING, EXCAVATING, OR OTHERWISE ALTERING THE TOTAL
WORK OR ANY OTHER PART OF IT. ALL PATCHING, REPAIRING AND REPLACING OF MATERIALS
AND SURFACES CUT OR DAMAGED IN EXECUTION OF WORK SHALL BE DONE WITH APPLICABLE
MATERIALS SO THAT SURFACES REPLACED WILL, UPON COMPLETION, MATCH SURROUNDING
SIMILAR SURFACES.
CONTRACTOR TO PROVIDE ALL NECESSARY BLOCKING, BACKING, AND FRAMING
FOR LIGHT FIXTURES, ELECTRICAL UNITS, EQUIPMENT, RECESSED ITEMS, AND ALL
OTHER ITEMS AS REQUIRED.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
DIMENSIONS:
A. ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE OF DRAWINGS.
B. ALL DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE U.N.O.
NO PORTION OF THE WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION SHALL
COMMENCE UNTIL THE SUBMISSION HAS BEEN REVIEWED BY THE ARCHITECT.
ALL SUCH PORTIONS OF THE WORK SHALL BE IN ACCORDANCE WITH REVIEWED SHOP
DRAWINGS AND SAMPLES. SHOP DRAWINGS AND PRODUCT SUBMITTALS ARE REQUIRED FOR
ALL SHOP FABRICATED WORK AS WELL AS SPECIFIED PRODUCTS. THIS WORK INCLUDES,
BUT NOT BE LIMITED TO WINDOW AND DOOR FRAMES AND ALL FINISH MATERIALS.
INSTALL FIRE STOPS AS FOLLOWS:
-IN CONCEALED SPACES OF STUD WALLS INCLUDING FURRED SPACES AT CEILING AND FLOOR LEVELS
AND AT 10' INTERVALS ALONG THE WALL LENGTH.
-IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES AND SIMILAR OPENINGS WHICH
AFFORD PASSAGE OF FIRE BETWEEN FLOOR LEVELS AND FLOOR TO CEILINGS OR ATTICS.
14.
DRAWINGS AND SPECIFICATIONS INDICATE REQUIREMENTS FOR NEW CONSTRUCTION ONLY. ARCHITECT NOT RESPONSIBLE FOR WEATHER TIGHTNESS, STRUCTURAL INTEGRITY, OR AESTHETIC PERFORMANCE OF
EXISTING CONSTRUCTION.
15.
COORDINATE WEATHER RESISTIVE BARRIER DETAILS AND PRODUCTS WITH MANUFACTURER AND ARCHITECT
BASED ON EXISTING CONDITIONS. APPROVED SUBSTITUTIONS MAY BE REQUIRED.
16.
YAEGER
500 KENNEDY DR
RANGELY
COLORADO
81 CRESCENT PLACE
GLENWOOD SPRINGS
COLORADO, 81601
rosenfeld-design.com
JOB NO.
SHEET NO.
TEL: 719.439.3335
ROSENFELD
D E S I G N
R
O S E N
F E
LD
D E S
IG
N
LL
C
C N
C C
Y A
E G
E R
B U
IL
D
IN
G
R A
N G
E
LY
C
O
LO
R A
D O
G101
GENERAL
INFORMATION
GENERAL
G100 COVER SHEET
G101 GENERAL INFORMATION
SURVEY
SHT - 1 SURVEY
CIVIL
C1 EXISTING CONDITIONS AND DEMO PLAN
C2 SITE AND GRADING PLAN
ARCHITECTURE
A100 EXISTING FLOOR PLAN
A200 EXTERIOR ELEVATIONS
A300 BUILDING SECTIONS
A400 ENLARGED WALL SECTIONS
A401 ENLARGED WALL SECTIONS
A500 EXTERIOR DETAILS
A501 EXTERIOR DETAILS
STRUCTURAL
S000 STRUCTURAL COVER SHEET
S001 GENERAL NOTES
S101 LEVEL 1 - FLOOR PLAN
S102 MEZZANINE - FLOOR PLAN
S601 WOOD FRAMING DETAILS
S602 WOOD FRAMING DETAILS
F
WV
S
S
S
G
124.4'
.5
4.2'
9.
2'
4.2'
.5
124.4'
.1
WOOD SHED43.5' X 13'
WOOD SHED
31.9' X 11.8'
CONCRETEPAD
PAVED AIRPLANE
PARKING
CONCRETE WALK
CONCRETE
RETAINING
ST
O
N E
CONCRETE
DRAIN STRUCTURE
GRATE:5457.0
8"PVC:5455.94-INV
ST
EP
S
SH
ED
TRASH
PAD
TWO - STORY
SHOP BUILDING
12'' C
MP
ASS
UMED
D
IR
EC
TIO
N
W
IVB
R
ET
A
IN
IN
G
DECORATIVE STONE
FACE(TYPICAL)
FF
E
SE
C
O N
D S
TO
R
Y .0
FF
E
M A
IN
S
H O
P F
LO
O
R
.3
FF
E
FR
O
N T
D O
O R
E N
TR
Y
.0
GRAVEL AREA
GRAVEL AREA
SITE BENCHMARK
SET MAG NAIL IN ASPHALT
ELEVATION:5456.8
N:1288117.50 E:2079504.25
RID
GE ROAD
PAVED ROADWAY
TRASHPAD
IN
V:5449.88
CONCRETEPAD
FF
E
H A
N G
ER
D
O O
R .2
OS W
WATERLINELOCATIONPERMAINTENANCESTAFF
FFEBAY DOOR5457.33
DRAIN INLET
NON-FUNCTIONAL
(FILL OF SEDIMENT)
(TYPICAL)
SURVEYOR'S STATEMENT
I, RODNEY P. KISER, DO HEREBY STATE THAT THIS EXISTING CONDITIONS MAP WAS PREPARED BY TRUE NORTH COLORADO, LLC. FOR ROSENFELD DESIGN, THAT SAID MAP WAS PREPARED BY ME OR UNDER MY SUPERVISION AND RESPONSIBLE CHARGE AND THAT IT IS TRUE AND CORRECT TO THE BEST OF MY BELIEF AND KNOWLEDGE.
ELECTRICAL OUTLET
WV
WATER VALVE
TELEPHONE PEDESTAL
DY
H
S
FIRE HYDRANT
SANITARY MANHOLE
ELECTRICAL TRANSFORMER
GAS METER
ELECTRICAL METER
G
LE*END
E
NOTES�
4. ELEVATIONS SHOWN HEREON ARE BASED ON GPS OBSERVATIONS UTILIZING THE CONTINUOUS OPERATING REFERENCE STATIONS (CORS) THROUGH THE MESA COUNTY RTVRN NETWORK BROAD CASTING NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88) YIELDING AN ON-SITE BENCHMARK ELEVATION OF 5456.8'.
5. CONTOUR INTERVAL EQUALS 1 FOOT.
YEAGER BUILDING - COLORADO NORTHWEST COMMUNITY COLLEGE
SECTION 1&12, TOWNSHIP 1 NORTH, RANGE 102 WEST OF THE 6TH P.M.
COUNTY OF RIO BLANCO, STATE OF COLORADO
EXISTING CONDITIONS MAP
TRUE NORTH COLORADO LLC.
A LAND SURVEYING AND MAPPING COMPANY
P.O. BOX 614 - 386 MAIN STREET UNIT 3
NEW CASTLE, COLORADO 81647
(970) 984-0474 www.truenorthcolorado.com
PROJECT NO: 2026-143
DATE: June 9, 2026
DRAWN
DJB
SURVEYED
DJB
SHEET
TRUENORTH
A LAND SURVEYING AND MAPPING COMPANY
16' 8' 32'
SCALE: 1" = 16'
NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY
LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE
YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT MAY ANY
ACTION BASED UPON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE
THAN TEN YEARS FROM THE DATE OF CERTIFICATION SHOWN HEREON.
CHAIN-LINK FENCE
CLEAN-OUT
N
ELECTRICAL SERVICE BOX
LIGHT POLE
FIBER VAULTF
STREET SIGN
DRAIN INLET
OSW WATER SPIGOT
G
WV
W
IVB
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
EX TREES (TYP)
EX IRRIGATION VALVE BOX
EX SANITARY SEWER MANHOLE (TYP)
EX LIGHTPOLE (TYP)
EX 12" CMP
EX WATER VALVE
EX WATER SPIGOT
EX FIBER OPTICS VAULT
EX ELECTRICAL TRANSFORMER
EX ELECTRIC METER EX TELEPHONE PEDESTAL
EX DRAIN INLETS TO BE REMOVED
EX CONCRETE STORM DRAIN
EX CONCRETE RETAINING WALL
EX STONE RETAINING WALL TO BE REMOVED
EX STONE FACE
EX TRASH PAD
EX ELECTRIC OUTLET
PROTECT EXISTING
TREES THROUGHOUT
CONSTRUCTION
430 MAIN STREET
CAÑON CITY, CO 81212
719.430.5333 www.3rocksengineering.com p:
\2
6\
.1
- c nc c ya eg er \h
-d w gs \c iv il\ sh ee ts \c nc c ya eg er -e x co nd iti on s a nd d em o pl an
.d w g 7/
/2
8:
:2
PM
N
AT
HA
N C
U
RT
IS
FOR MUNICIPAL USE:
10'
SCALE: 1" = 20'
0 20'
N
CN
CC
Y
AE
GE
R
PROJECT ENG:NRC
QA/QC:----
DRAWN BY:MPH
PRJ # 26.147
DATE: 6/24/2026
C1
EXISTING CONDITIONS
AND DEMO PLAN
KE
N
N
ED
Y
DR
IV
E, RA
N
GL
EY
, C O
/2
ISSUED DATES
V1.0-6/24/2026
LEGEND
X X
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
EXISTING FENCE
EXISTING WATER LINE
EXISTING GRAVEL
EXISTING ASPHALT
EXISTING CONCRETE
Digitally signed by Nathan Curtis Date:
2026.07.15 20:06:38-06'00'
G
WV
W
IVB
STRM
STRM
STRM
STRM
STRM
STRM
-0 .2
-5 .0
-1 2.
2%
-5.1%
-6.5%
-4.8%
5457.29
5456.03
5454.49
5452.68
5456.89
5456.83
5454.74
5456.43
5454.44
BOW: 5458.00
TOW: 5458.31
5457.37
5457.37
5457.37
5457.37
-6 .5
-6 .5
-8
.6
-3.9%
ADJUST UTILITY METERS AND
INFRASTRUCTURE AS NEEDED
WITH THE NEW GRADING
TOW: 5459.03
5456.90
5456.90
5457.55
5457.66
5457.55
5457.37
5457.37
PROP SWALE
PROP FRENCH DRAIN
PROVIDE 6" OF COVER OVER
6" PERFORATED PIPE
BOW: 5458.00
BOW: 5457.55
TOW: 5458.96
5457.45
5457.45 5457.92
6" HDPE @ 0.5% MIN
6" HDPE @ 1% MIN
INV: 5455.94
PROTECT EXISTING TREES
THROUGHOUT CONSTRUCTION
PROTECT EXISTING TREES
THROUGHOUT CONSTRUCTION
PROPOSED BOULDER
RETAINING WALL, USE
BOULDERS ON SITE ROUGHLY
2' IN DIAMETER
5457.37
5457.83
PROP FRENCH DRAIN
PROVIDE 6" OF COVER OVER
6" PERFORATED PIPE
430 MAIN STREET
CAÑON CITY, CO 81212
719.430.5333 www.3rocksengineering.com p:
\2
6\
.1
- c nc c ya eg er \h
-d w gs \c iv il\ sh ee ts \c nc c ya eg er -s ite a nd g ra di ng p la n.
dw g
7/
/2
8:
:2
PM
N
AT
HA
N
C U
RT
IS
FOR MUNICIPAL USE:
10'
SCALE: 1" = 20'
0 20'
N
CN
CC
Y
AE
GE
R
PROJECT ENG:NRC
QA/QC:----
DRAWN BY:MPH
PRJ # 26.147
DATE: 6/24/2026
C2
SITE AND GRADING PLAN
KE
N
N
ED
Y
DR
IV
E, RA
N
GL
EY
, C O
/2
ISSUED DATES
##/##/##-V1.0
Digitally signed by Nathan Curtis Date:
2026.07.15 20:06:43-06'00'
UP
UP
DN
A200
A200
A2002A200 4
V.I.F.
16' - 5 3/4"
V.I.F.
41' - 4"
A300
A300
AA
BB
CC
DD
EE
124' - 0"
A300
A300
20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 24' - 0"
A300
A300
A300
A300
(E) SHOP
CLASSROOM
(E)
CLASSROOM
(E) LOBBY
(E)
CLEANING
(E) LAB
(E)
CLASSROOM
110 (E) OFFICE
(E) OFFICE
(E) OFFICE
(E)
RESTROOM
(E)
RESTROOM
(E)
CUSTODIAN
(E) OFFICE
(E) SHOP
CLASSROOM
(E) SHED
(E) SHED
NEW 2X4 SUSPENDED ACOUSTIC CEILING
TILE AT (E) CLASSROOM 101 AT 10'-0" ABOVE
FINISHED FLOOR. USG DONN BRAND DX/DXL
SQUARE PROFILE SIMILAR TO EXISTING.
REINSTALL EXISTING LIGHTING. REPAIR AND
REPAINT EXISTING WALL FINISH AS
REQUIRED. INSTALL GYP BOARD AT
UNCOVERED WALL CAVITIES, TO MATCH (E)
WALL GYP BOARD THICKNESS AND FINISH
REPAIR OR REPLACE INTERIOR FINISHES AND
FIXTURES DAMAGED BY SHORING
INSTALLATION WITH LIKE MATERIALS, TYP
REPAIR OR REPLACE INTERIOR FINISHES AND
FIXTURES DAMAGED BY SHORING,
INSTALLATION WITH LIKE MATERIALS, TYP
ELIMINATE AND INFILL
DOOR LEAF WITH
FRAMED WALL TO
MATCH EXISTING PER
OWNER REQUEST
NEW BOULDER WALL AND
FRENCH DRAIN PER CIVIL
ENGINEER
PROTECT EXISTING TREES TO
REMAIN
NEW FRENCH DRAIN PER CIVIL
ENGINEER
NEW CONSTRUCTION TO REPLACE
EXISTING
EXISTING TO REMAIN
GRAPHIC LEGEND
1. GENERAL CONTRACTOR TO COORDINATE
CONSTRUCTION SCHEDULING, EXTENTS AND
SAFETY WITH BUILDING OCCUPANTS. FACILITY TO
REMAIN IN USE DURING CONSTRUCTION.
2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE
FOR PROTECTING ALL REMAINING FINISHES AND
EQUIPMENT WITHIN THE FACILITY AS REQUIRED
TO AVOID DAMAGE.
3. STRUCTURAL COMPONENTS (TRUSSES,
COLUMNS, BEAMS) TO REMAIN UNMODIFIED
UNLESS OTHERWISE NOTED.
GENERAL NOTES
81 CRESCENT PLACE
GLENWOOD SPRINGS
COLORADO, 81601
rosenfeld-design.com
JOB NO.
SHEET NO.
TEL: 719.439.3335
ROSENFELD
D E S I G N
R
O S E N
F E
LD
D E S
IG
N
LL
C
C N
C C
Y A
E G
E R
B U
IL
D
IN
G
R A
N G
E
LY
C
O
LO
R A
D O
A100
EXISTING FLOOR
PLAN
NORTH
0 2 8 16
1/8" = 1'-0"
MAIN LEVEL FLOOR PLAN
T.O. FOOTING
99' - 1 1/2"
TOP PLATE
116' - 9"
ENTRY FLOOR
100' - 7 3/4"
T.O. STONE
112' - 9"
A300
1234567
A300
SHOP FLOOR
100' - 0"
T.O. CMU
102' - 4"
MEZZANINE
109' - 8 1/4"
T.O. CURB
100' - 4"
NEW SIDING TO MATCH EXISTING
FINISH AND ORIENTATION. QUALITY
EDGE TRUCEDAR STEEL SIDING 414
IRONSTONE BOARD AND BATTEN
ALTERNATING 6" AND 10" WIDTHS.
INSTALL PER MANUFACTURER'S
REQUIREMENTS
NEW SIDING TO MATCH EXISTING
FINISH AND ORIENTATION. QUALITY
EDGE VESTA STEEL SIDING 486
AMBER CHERRY. INSTALL PER
MANUFACTURER'S REQUIREMENTS
T.O. FOOTING
99' - 1 1/2"
TOP PLATE
116' - 9"
ENTRY FLOOR
100' - 7 3/4"
T.O. STONE
112' - 9"
A B C D E
SHOP FLOOR
100' - 0"
T.O. CMU
102' - 4"
A300
MEZZANINE
109' - 8 1/4"
A300
T.O. CURB
100' - 4"
T.O. FOOTING
99' - 1 1/2"
TOP PLATE
116' - 9"
ENTRY FLOOR
100' - 7 3/4"
T.O. STONE
112' - 9"
A300
1 2 3 4 5 6 7
A300
SHOP FLOOR
100' - 0"
T.O. CMU
102' - 4"
MEZZANINE
109' - 8 1/4"
T.O. CURB
100' - 4"
NEW SIDING TO MATCH EXISTING
FINISH AND ORIENTATION. QUALITY
EDGE TRUCEDAR STEEL SIDING 414
IRONSTONE BOARD AND BATTEN
ALTERNATING 6" AND 10" WIDTHS.
INSTALL PER MANUFACTURER'S
REQUIREMENTS
T.O. FOOTING
99' - 1 1/2"
TOP PLATE
116' - 9"
ENTRY FLOOR
100' - 7 3/4"
T.O. STONE
112' - 9"
ABCDE
SHOP FLOOR
100' - 0"
T.O. CMU
102' - 4"
A300
MEZZANINE
109' - 8 1/4"
A300
T.O. CURB
100' - 4"
1. GENERAL CONTRACTOR TO COORDINATE
CONSTRUCTION SCHEDULING, EXTENTS AND
SAFETY WITH BUILDING OCCUPANTS. FACILITY TO
REMAIN IN USE DURING CONSTRUCTION.
2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE
FOR PROTECTING ALL REMAINING FINISHES AND
EQUIPMENT WITHIN THE FACILITY AS REQUIRED
TO AVOID DAMAGE.
3. STRUCTURAL COMPONENTS (TRUSSES,
COLUMNS, BEAMS) TO REMAIN UNMODIFIED
UNLESS OTHERWISE NOTED.
GENERAL NOTES
NEW CONSTRUCTION TO REPLACE
EXISTING
EXISTING TO REMAIN
ELEVATION / SECTION GRAPHIC LEGEND
81 CRESCENT PLACE
GLENWOOD SPRINGS
COLORADO, 81601
rosenfeld-design.com
JOB NO.
SHEET NO.
TEL: 719.439.3335
ROSENFELD
D E S I G N
R
O S E N
F E
LD
D E S
IG
N
LL
C
C N
C C
Y A
E G
E R
B U
IL
D
IN
G
R A
N G
E
LY
C
O
LO
R A
D O
A200
EXTERIOR
ELEVATIONS
0 2 8 161/8" = 1'-0"
NORTH ELEVATION
1/8" = 1'-0"
EAST ELEVATION
1/8" = 1'-0"
SOUTH ELEVATION
1/8" = 1'-0"
WEST ELEVATION
TOP PLATE
116' - 9"
ENTRY FLOOR
100' - 7 3/4"
T.O. STONE
112' - 9"
A300
1 2 3 4 5 6 7
A300
SHOP FLOOR
100' - 0"
T.O. CMU
102' - 4"
MEZZANINE
109' - 8 1/4"
(E) SHOP
CLASSROOM
(E)
RESTROOM
106(E) LOBBY
A401
T.O. CURB
100' - 4"
T.O. FOOTING
99' - 1 1/2"
TOP PLATE
116' - 9"
ENTRY FLOOR
100' - 7 3/4"
T.O. STONE
112' - 9"
A300
1 2 3 4 5 6 7
A300
SHOP FLOOR
100' - 0"
T.O. CMU
102' - 4"
MEZZANINE
109' - 8 1/4"
(E) SHOP
CLASSROOM
(E)
CLASSROOM
A400
T.O. CURB
100' - 4"
T.O. FOOTING
99' - 1 1/2"
TOP PLATE
116' - 9"
ENTRY FLOOR
100' - 7 3/4"
T.O. STONE
112' - 9"
A B C D E
SHOP FLOOR
100' - 0"
T.O. CMU
102' - 4"
A300
MEZZANINE
109' - 8 1/4"
A300
(E)
CLASSROOM
(E) LOBBY
(E)
CUSTODIAN
A400
A401
T.O. CURB
100' - 4"
T.O. FOOTING
99' - 1 1/2"
TOP PLATE
116' - 9"
ENTRY FLOOR
100' - 7 3/4"
T.O. STONE
112' - 9"
A B C D E
SHOP FLOOR
100' - 0"
T.O. CMU
102' - 4"
A300
MEZZANINE
109' - 8 1/4"
A300
(E) SHOP
CLASSROOM
(E) LAB
(E) SHOP
CLASSROOM
(E) SHED
A400
T.O. CURB
100' - 4"
1. GENERAL CONTRACTOR TO COORDINATE
CONSTRUCTION SCHEDULING, EXTENTS AND
SAFETY WITH BUILDING OCCUPANTS. FACILITY TO
REMAIN IN USE DURING CONSTRUCTION.
2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE
FOR PROTECTING ALL REMAINING FINISHES AND
EQUIPMENT WITHIN THE FACILITY AS REQUIRED
TO AVOID DAMAGE.
3. STRUCTURAL COMPONENTS (TRUSSES,
COLUMNS, BEAMS) TO REMAIN UNMODIFIED
UNLESS OTHERWISE NOTED.
GENERAL NOTES
NEW CONSTRUCTION TO REPLACE
EXISTING
EXISTING TO REMAIN
ELEVATION / SECTION GRAPHIC LEGEND
81 CRESCENT PLACE
GLENWOOD SPRINGS
COLORADO, 81601
rosenfeld-design.com
JOB NO.
SHEET NO.
TEL: 719.439.3335
ROSENFELD
D E S I G N
R
O S E N
F E
LD
D E S
IG
N
LL
C
C N
C C
Y A
E G
E R
B U
IL
D
IN
G
R A
N G
E
LY
C
O
LO
R A
D O
A300
BUILDING SECTIONS
0 2 8 161/8" = 1'-0"
BUILDING SECTION A
1/8" = 1'-0"
BUILDING SECTION B
1/8" = 1'-0"
BUILDING SECTION C
1/8" = 1'-0"
BUILDING SECTION D
TOP PLATE
116' - 9"
T.O. STONE
112' - 9"
E
SHOP FLOOR
100' - 0"
MEZZANINE
109' - 8 1/4"
A500
T.O. CURB
100' - 4"
(E) SHOP
CLASSROOM
TIE IN NEW WEATHER RESISTIVE
BARRIER AND SIDING INTO EXISTING.
NEW SIDING FINISH AND ORIENTATION
TO MATCH EXISTING
REMOVE EXISTING GRADE PER CIVIL
REFERENCE STRUCTURAL FOR REPAIR
TO EXISTING WALL FRAMING. FILL
DISTURBED CAVITIES SOLID WITH BATT
INSULATION. REPAIR, REPLACE AND
REPAINT GYP BOARD TO MATCH
EXISTING AS REQUIRED
NEW GRADE PER CIVIL ENGINEER
CLEAN AND PREP EXISTING
FOUNDATION TO RECEIVE NEW
WATERPROOFING AND FOUNDATION
DRAINAGE MEDIUM
REPAIR / REPLACE ALL CEILINGS AND
WALL FINISHES REMOVED TO INSTALL
TEMPORARY SHORING, TYP. ASSEMBLY
AND FINISH TO MATCH EXISTING
T.O. FOOTING
99' - 1 1/2"
TOP PLATE
116' - 9"
T.O. STONE
112' - 9"
E
SHOP FLOOR
100' - 0"
MEZZANINE
109' - 8 1/4"
A500
T.O. CURB
100' - 4"
(E)
CLASSROOM
TIE IN NEW WEATHER RESISTIVE
BARRIER AND SIDING INTO EXISTING.
NEW SIDING FINISH AND ORIENTATION
TO MATCH EXISTING
REMOVE EXISTING GRADE PER CIVIL
REFERENCE STRUCTURAL FOR REPAIR
TO EXISTING WALL FRAMING. FILL
DISTURBED CAVITIES SOLID WITH BATT
INSULATION. REPAIR, REPLACE AND
REPAINT GYP BOARD TO MATCH
EXISTING AS REQUIRED
NEW GRADE PER CIVIL ENGINEER
CLEAN AND PREP EXISTING
FOUNDATION TO RECEIVE NEW
WATERPROOFING AND FOUNDATION
DRAINAGE MEDIUM
NEW 2X4 SUSPENDED ACOUSTIC
CEILING TILE AT (E) CLASSROOM 101 AT
10'-0" ABOVE FINISHED FLOOR. USG
DONN BRAND DX/DXL SQUARE PROFILE
SIMILAR TO EXISTING. REINSTALL
EXISTING LIGHTING. REPAIR AND
REPAINT EXISTING WALL FINISH AS
REQUIRED. INSTALL GYP BOARD AT
UNCOVERED WALL CAVITIES, TO MATCH
(E) WALL GYP BOARD THICKNESS AND
FINISH
REPAIR / REPLACE ALL CEILINGS AND
WALL FINISHES REMOVED TO INSTALL
TEMPORARY SHORING, TYP. ASSEMBLY
AND FINISH TO MATCH EXISTING
T.O. FOOTING
99' - 1 1/2"
TOP PLATE
116' - 9"
T.O. STONE
112' - 9"
SHOP FLOOR
100' - 0"
MEZZANINE
109' - 8 1/4"
T.O. CURB
100' - 4"
(E)
CLASSROOM
REMOVE EXISTING GRADE PER CIVIL
REFERENCE STRUCTURAL FOR REPAIR
TO EXISTING WALL FRAMING. FILL
DISTURBED CAVITIES SOLID WITH BATT
INSULATION. REPAIR, REPLACE AND
REPAINT GYP BOARD TO MATCH
EXISTING AS REQUIRED
NEW GRADE PER CIVIL ENGINEER
CLEAN AND PREP EXISTING
FOUNDATION TO RECEIVE NEW
WATERPROOFING AND FOUNDATION
DRAINAGE MEDIUM
REPAIR OR REPLACE DAMAGED
EXISTING STONE VENEER AS REQUIRED
NEW 2X4 SUSPENDED ACOUSTIC
CEILING TILE AT (E) CLASSROOM 101 AT
10'-0" ABOVE FINISHED FLOOR. USG
DONN BRAND DX/DXL SQUARE PROFILE
SIMILAR TO EXISTING. REINSTALL
EXISTING LIGHTING. REPAIR AND
REPAINT EXISTING WALL FINISH AS
REQUIRED. INSTALL GYP BOARD AT
UNCOVERED WALL CAVITIES, TO MATCH
(E) WALL GYP BOARD THICKNESS AND
FINISH
A500
REPAIR / REPLACE ALL CEILINGS AND
WALL FINISHES REMOVED TO INSTALL
TEMPORARY SHORING, TYP. ASSEMBLY
AND FINISH TO MATCH EXISTING
1. GENERAL CONTRACTOR TO COORDINATE
CONSTRUCTION SCHEDULING, EXTENTS AND
SAFETY WITH BUILDING OCCUPANTS. FACILITY TO
REMAIN IN USE DURING CONSTRUCTION.
2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE
FOR PROTECTING ALL REMAINING FINISHES AND
EQUIPMENT WITHIN THE FACILITY AS REQUIRED
TO AVOID DAMAGE.
3. STRUCTURAL COMPONENTS (TRUSSES,
COLUMNS, BEAMS) TO REMAIN UNMODIFIED
UNLESS OTHERWISE NOTED.
GENERAL NOTES
NEW CONSTRUCTION TO REPLACE
EXISTING
EXISTING TO REMAIN
ELEVATION / SECTION GRAPHIC LEGEND
81 CRESCENT PLACE
GLENWOOD SPRINGS
COLORADO, 81601
rosenfeld-design.com
JOB NO.
SHEET NO.
TEL: 719.439.3335
ROSENFELD
D E S I G N
R
O S E N
F E
LD
D E S
IG
N
LL
C
C N
C C
Y A
E G
E R
B U
IL
D
IN
G
R A
N G
E
LY
C
O
LO
R A
D O
A400
ENLARGED WALL
SECTIONS
3/4" = 1'-0"
NORTH SECTION AT SHOP
3/4" = 1'-0"
NORTH SECTION AT CLASSROOM
3/4" = 1'-0"
EAST SECTION AT CLASSROOM
TOP PLATE
116' - 9"
T.O. STONE
112' - 9"
SHOP FLOOR
100' - 0"
T.O. CMU
102' - 4"
MEZZANINE
109' - 8 1/4"
T.O. CURB
100' - 4"
(E)
RESTROOM
TIE IN NEW WEATHER RESISTIVE
BARRIER AND SIDING INTO EXISTING.
NEW SIDING FINISH AND ORIENTATION
TO MATCH EXISTING
REMOVE EXISTING GRADE PER CIVIL
REFERENCE STRUCTURAL FOR REPAIR
TO EXISTING WALL FRAMING. FILL
DISTURBED CAVITIES SOLID WITH BATT
INSULATION. REPAIR, REPLACE AND
REPAINT GYP BOARD TO MATCH
EXISTING AS REQUIRED
NEW GRADE PER CIVIL ENGINEER
CLEAN AND PREP EXISTING
FOUNDATION TO RECEIVE NEW
WATERPROOFING AND FOUNDATION
DRAINAGE MEDIUM
REPAIR / REPLACE ALL CEILINGS AND
WALL FINISHES REMOVED TO INSTALL
TEMPORARY SHORING, TYP. ASSEMBLY
AND FINISH TO MATCH EXISTING
A501
T.O. FOOTING
99' - 1 1/2"
TOP PLATE
116' - 9"
T.O. STONE
112' - 9"
A
SHOP FLOOR
100' - 0"
T.O. CMU
102' - 4"
MEZZANINE
109' - 8 1/4"
T.O. CURB
100' - 4"
(E)
CUSTODIAN
TIE IN NEW WEATHER RESISTIVE
BARRIER AND SIDING INTO EXISTING.
NEW SIDING FINISH AND ORIENTATION
TO MATCH EXISTING
REMOVE EXISTING GRADE PER CIVIL
REFERENCE STRUCTURAL FOR REPAIR
TO EXISTING WALL FRAMING. FILL
DISTURBED CAVITIES SOLID WITH BATT
INSULATION. REPAIR, REPLACE AND
REPAINT GYP BOARD TO MATCH
EXISTING AS REQUIRED
NEW GRADE PER CIVIL ENGINEER
CLEAN AND PREP EXISTING
FOUNDATION TO RECEIVE NEW
WATERPROOFING AND FOUNDATION
DRAINAGE MEDIUM
REPAIR / REPLACE ALL CEILINGS AND
WALL FINISHES REMOVED TO INSTALL
TEMPORARY SHORING, TYP. ASSEMBLY
AND FINISH TO MATCH EXISTING
A500
1. GENERAL CONTRACTOR TO COORDINATE
CONSTRUCTION SCHEDULING, EXTENTS AND
SAFETY WITH BUILDING OCCUPANTS. FACILITY TO
REMAIN IN USE DURING CONSTRUCTION.
2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE
FOR PROTECTING ALL REMAINING FINISHES AND
EQUIPMENT WITHIN THE FACILITY AS REQUIRED
TO AVOID DAMAGE.
3. STRUCTURAL COMPONENTS (TRUSSES,
COLUMNS, BEAMS) TO REMAIN UNMODIFIED
UNLESS OTHERWISE NOTED.
GENERAL NOTES
NEW CONSTRUCTION TO REPLACE
EXISTING
EXISTING TO REMAIN
ELEVATION / SECTION GRAPHIC LEGEND
81 CRESCENT PLACE
GLENWOOD SPRINGS
COLORADO, 81601
rosenfeld-design.com
JOB NO.
SHEET NO.
TEL: 719.439.3335
ROSENFELD
D E S I G N
R
O S E N
F E
LD
D E S
IG
N
LL
C
C N
C C
Y A
E G
E R
B U
IL
D
IN
G
R A
N G
E
LY
C
O
LO
R A
D O
A401
ENLARGED WALL
SECTIONS
3/4" = 1'-0"
EAST SECTION AT RESTROOM
3/4" = 1'-0"
SOUTH SECTION AT CUSTODIAN
NEW BITUTHENE FLEXIBLE FLASHING AT
WALL BASE
NEW METAL WALL PANEL TO MATCH
EXISTING TO REMAIN ABOVE. PROVIDE
NEW FURRING TO ALIGN TO EXISTING
AS REQUIRED. INSTALL PER
MANUFACTURER'S REQUIREMENTS
NEW SLOPED PREFINISHED FLASHING
TO MATCH METAL PANEL METAL MIN 4"
ABOVE / BELOW TOP OF CURB
EXISTING SLAB
AND
FOUNDATION TO
REMAIN
LAP NEW WEATHER RESISTIVE BARRIER
OVER FLASHING
MIN R-20 RIGID INSULATION BOARD W/
BEVELED TOP, EXTEND TO TOP OF
FOOTING
NEW CANT BEAD OF CONT LIQUID
SEALANT
NEW METAL WALL VENEER SYSTEM
TRIM WITH WEEP HOLES
CLEAN AND PREP (E) FOUNDATION
AND INSTALL NEW FLUID APPLIED
FOUNDATION WATERPROOFING.
TREMCO TREMPROOF OR APPROVED
EQUAL. INSTALL PER
MANUFACTURER'S REQUIREMENTS
REFERENCE STRUCTURAL FOR REPAIR
TO EXISTING WALL FRAMING AND NEW
SHEATHING. FILL DISTURBED CAVITIES
SOLID WITH BATT INSULATION. REPAIR,
REPLACE AND REPAINT GYP BOARD TO
MATCH EXISTING AS REQUIRED
NEW GRADE PER CIVIL ENGINEER
TIE IN NEW METAL PANEL CLADDING TO
MATCH EXISTING
EXISTING GRADE TO BE REMOVED. RE:
CIVIL ENGINEERING DRAWINGS
LAP EXSTING WRB OVER NEW FULLY
ADHERED WRB MIN 6". REVERSE LAPS
NOT ALLOWED. CLEAN AND PREP
EXISTING SHEATHING TO REMAIN TO
RECEIVE NEW ADHERED WRB. PRIMER
AND VAPROBOND TOOLING PER
MANUFACTURER'S REQUIREMENTS
MAY BE NECESSARY
R-20 RIGID INSULATION TO TOTAL 36" MINIMUM
COMBINED VERTICAL AND HORIZONTAL
EXISTING SLAB
AND
FOUNDATION TO
REMAIN
REFERENCE STRUCTURAL FOR REPAIR
TO EXISTING WALL FRAMING. FILL
DISTURBED CAVITIES SOLID WITH BATT
INSULATION. REPAIR, REPLACE AND
REPAINT GYP BOARD TO MATCH
EXISTING AS REQUIRED
REPAIR OR REPLACE DAMAGED
EXISTING STONE VENEER AS
REQUIRED
NEW DARK BRONZE SLOPED
PREFINISHED FLASHING MIN 4" BELOW
TOP OF CURB. SAW CUT INTO EXISTING
STONE JOINT
MIN R-20 RIGID INSULATION BOARD W/
BEVELED TOP, EXTEND TO TOP OF
FOOTING
CLEAN AND PREP (E) FOUNDATION
AND INSTALL NEW CONTINUOUS
DRAINAGE MEDIUM (ONLY AT
LOCATIONS WITH FRENCH DRAIN
SPECIFIED BY CIVIL ENGINEER) OVER
NEW FLUID APPLIED FOUNDATION
WATERPROOFING. TREMCO
TREMPROOF 250GC AND TREMDRAIN
1000PF OR APPROVED EQUAL.
INSTALL PER MANUFACTURER'S
REQUIREMENTS
R-20 RIGID INSULATION TO TOTAL 36" MINIMUM
COMBINED VERTICAL AND HORIZONTAL
NEW GRADE PER CIVIL ENGINEER
EXISTING GRADE TO BE REMOVED. RE:
CIVIL ENGINEERING DRAWINGS
NEW SLOPED FRENCH DRAIN
PER CIVIL ENGINEER
GRAVEL FILL AND FILTER
FABRIC AT FRENCH DRAIN
LOCATIONS
3/4" CANT OF TREMCO DYMONIC 100
PRIOR TO APPLICATION OF FLUID-
APPLIED WATERPROOFING.
INSTALL PER MANUFACTURER'S
REQUIREMENTS
NEW CONSTRUCTION TO REPLACE
EXISTING
EXISTING TO REMAIN
GRAPHIC LEGEND
1. GENERAL CONTRACTOR TO COORDINATE
CONSTRUCTION SCHEDULING, EXTENTS AND
SAFETY WITH BUILDING OCCUPANTS. FACILITY TO
REMAIN IN USE DURING CONSTRUCTION.
2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE
FOR PROTECTING ALL REMAINING FINISHES AND
EQUIPMENT WITHIN THE FACILITY AS REQUIRED
TO AVOID DAMAGE.
3. STRUCTURAL COMPONENTS (TRUSSES,
COLUMNS, BEAMS) TO REMAIN UNMODIFIED
UNLESS OTHERWISE NOTED.
GENERAL NOTES
81 CRESCENT PLACE
GLENWOOD SPRINGS
COLORADO, 81601
rosenfeld-design.com
JOB NO.
SHEET NO.
TEL: 719.439.3335
ROSENFELD
D E S I G N
R
O S E N
F E
LD
D E S
IG
N
LL
C
C N
C C
Y A
E G
E R
B U
IL
D
IN
G
R A
N G
E
LY
C
O
LO
R A
D O
A500
EXTERIOR DETAILS
3" = 1'-0"
NEW SIDING AT NEW GRADE
3" = 1'-0"
EXISTING STONE AT NEW GRADE
EXISTING SLAB
AND
FOUNDATION TO
REMAIN
REFERENCE STRUCTURAL FOR REPAIR
TO EXISTING WALL FRAMING. FILL
DISTURBED CAVITIES SOLID WITH BATT
INSULATION. REPAIR, REPLACE AND
REPAINT GYP BOARD TO MATCH
EXISTING AS REQUIRED
REPAIR OR REPLACE DAMAGED
EXISTING STONE VENEER AS
REQUIRED
NEW DARK BRONZE SLOPED
PREFINISHED FLASHING MIN 4" BELOW
TOP OF CURB. SAW CUT INTO EXISTING
CMU JOINT
NEW GRADE PER CIVIL ENGINEER
EXISTING GRADE TO BE REMOVED. RE:
CIVIL ENGINEERING DRAWINGS
REPAIR AND CLEAN EXISTING CMU
THOROUGHLY. PREP FOR AND APPLY
CONCRETE WATERPROOF COLOR
COATING PER MANUFACTURER
REQUIREMENTS, SHERWIN WILLIAMS
LOXON XP OR APPROVED EQUAL.
COORDINATE WITH ARCHITECT ON
COLOR AND PROVIDE MOCKUP FOR
OWNER REVIEW
MIN R-20 RIGID INSULATION BOARD W/
BEVELED TOP, EXTEND TO TOP OF
FOOTING
CLEAN AND PREP (E) FOUNDATION
AND INSTALL NEW CONTINUOUS
DRAINAGE MEDIUM (ONLY AT
LOCATIONS WITH FRENCH DRAIN
SPECIFIED BY CIVIL ENGINEER) OVER
NEW FLUID APPLIED FOUNDATION
WATERPROOFING. TREMCO
TREMPROOF 250GC AND TREMDRAIN
1000PF OR APPROVED EQUAL.
INSTALL PER MANUFACTURER'S
REQUIREMENTS
NEW SLOPED FRENCH DRAIN
PER CIVIL ENGINEER
GRAVEL FILL AND FILTER
FABRIC AT FRENCH DRAIN
LOCATIONS
3/4" CANT OF TREMCO DYMONIC 100
PRIOR TO APPLICATION OF FLUID-
APPLIED WATERPROOFING.
INSTALL PER MANUFACTURER'S
REQUIREMENTS
R-20 RIGID INSULATION TO TOTAL 36" MINIMUM
COMBINED VERTICAL AND HORIZONTAL
NEW CONSTRUCTION TO REPLACE
EXISTING
EXISTING TO REMAIN
GRAPHIC LEGEND
1. GENERAL CONTRACTOR TO COORDINATE
CONSTRUCTION SCHEDULING, EXTENTS AND
SAFETY WITH BUILDING OCCUPANTS. FACILITY TO
REMAIN IN USE DURING CONSTRUCTION.
2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE
FOR PROTECTING ALL REMAINING FINISHES AND
EQUIPMENT WITHIN THE FACILITY AS REQUIRED
TO AVOID DAMAGE.
3. STRUCTURAL COMPONENTS (TRUSSES,
COLUMNS, BEAMS) TO REMAIN UNMODIFIED
UNLESS OTHERWISE NOTED.
GENERAL NOTES
81 CRESCENT PLACE
GLENWOOD SPRINGS
COLORADO, 81601
rosenfeld-design.com
JOB NO.
SHEET NO.
TEL: 719.439.3335
ROSENFELD
D E S I G N
R
O S E N
F E
LD
D E S
IG
N
LL
C
C N
C C
Y A
E G
E R
B U
IL
D
IN
G
R A
N G
E
LY
C
O
LO
R A
D O
A501
EXTERIOR DETAILS
3" = 1'-0"
EXISTING CMU AT NEW GRADE
STATEMENT OF SPECIAL INSPECTIONS - 2021 IBC
THIS STATEMENT OF SPECIAL INSPECTIONS IS SUBMITTED IN FULFILLMENT OF THE REQUIREMENTS OF THE 2021
INTERNATIONAL BUILDING CODE (IBC SECTION 1704 AND 1705).
SPECIAL INSPECTIONS AND TESTS APPLICABLE TO THIS PROJECT:
SPECIAL INSPECTORS SHALL REFER TO THE APPROVED PLANS AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. ANY ADDITIONAL TESTS AND INSPECTIONS REQUIRED BY THE APPROVED PLANS AND
SPECIFICATIONS WILL ALSO BE PERFORMED.
SPECIAL INSPECTIONS AND TESTING SHALL BE PERFORMED IN ACCORDANCE WITH THE APPROVED PLANS AND
SPECIFICATIONS, THIS STATEMENT AND IBC CHAPTER 17.
OWNER SHALL EMPLOY ONE OF MORE APPROVED AGENCIES TO PERFORM SPECIAL INSPECTIONS AND TEST AS
REQUIRED IN IBC SECTION 1704.2 AND WITH THE JURISDICTION HAVING AUTHORITY.
A FINAL SPECIAL INSPECTION REPORT SHALL BE SUBMITTED TO OWNER, THE AUTHORITY HAVING JURISDICTION, AND THE STRUCTURAL ENGINEER IN RESPONSIBLE CHARGE IN ACCORDANCE WITH IBC SECTION 1704.2.4.
DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNER, THE AUTHORITY HAVING
JURISDICTION AND THE STRUCTURAL ENGINEER ONCE DISCOVERED.
THIS STATEMENT OF SPECIAL INSPECTIONS HAS BEEN DEVELOPED WITH THE UNDERSTANDING THAT THE
OWNER WILL:
• REVIEW AND APPROVE THE QUALIFICATIONS OF THE SPECIAL INSPECTORS WHO WILL PERFORM THE
INSPECTIONS
• MONITOR SPECIAL INSPECTION ACTIVITIES ON THE JOB SITE TO ASSURE THAT THE SPECIAL INSPECTORS ARE
QUALIFIED AND ARE PERFORMING THEIR DUTIES AS CALLED FOR IN THIS STATEMENT OF SPECIAL INSPECTION
• REVIEW SUBMITTED INSPECTION REPORTS
• PERFORM INSPECTION AS REQUIRED BY IBC CHAPTER 17 AND ANY CITY/COUNTY/STATE STATUTE
REQUIREMENT
REQUIRED
REQUIRED
FREQUENCY & NOTES
PER SEOR
REF: IBC
SPECIAL INSPECTION
STRUCTURAL OBSERVATIONS FOR STRUCTURES
STRUCTURAL STEEL CONSTRUCTION
STAINLESS STEEL
COLD-FORMED STEEL DECKS
OPEN-WEB JOISTS
COLD-FORMED STEEL TRUSSES, SPAN >60 FT
METAL BUILDING SYSTEMS
CONCRETE CONSTRUCTION
WELDING OF REINFORCING BARS
MATERIAL TESTS
MASONRY CONSTRUCTION
EMPIRICAL, GLASS UNIT, VENEER (RISK CAT. IV) . . .
VERTICAL MASONRY FOUNDATION ELEMENTS
WOOD CONSTRUCTION
HIGH-LOAD DIAPHRAGMS
METAL-PLATE-CONNECTED TRUSSES, SPAN>60FT . .
MASS TIMBER CONSTRUCTION
SOILS
DRIVEN DEEP FOUNDATIONS
CAST IN PLACE DEEP FOUNDATIONS
HELICAL PILE FOUNDATIONS
STRUCTURAL INTEGRITY OF DEEP FOUNDATION
ELEMENTS
FABRICATED ITEMS
WIND RESISTANCE
STRUCTURAL WOOD
COLD-FORMED STEEL LIGHT-FRAME CONST
WIND-RESISTING COMPONENTS
SEISMIC RESISTANCE
TESTING FOR SEISMIC RESISTANCE
SEALING OF MASS TIMBER
CODE REFERENCE
(IBC 1704.6.1)
(IBC 1705.2.1)
(IBC 1705.2.2)
(IBC 1705.2.3)
(IBC 1705.2.4)
(IBC 1705.2.5)
(IBC 1705.2.6)
(IBC 1705.3)
(IBC 1705.3.1)
(IBC 1705.3.2)
(IBC 1705.4)
(IBC 1705.4.1)
(IBC 1705.4.2)
(IBC 1705.5)
(IBC 1705.5.1)
(IBC 1705.5.2)
(IBC 1705.5.3)
(IBC 1705.6)
(IBC 1705.7)
(IBC 1705.8)
(IBC 1705.9)
(IBC 1705.10)
(IBC 1705.11)
(IBC 1705.12)
(IBC 1705.12.1)
(IBC 1705.12.2)
(IBC 1705.12.3)
(IBC 1705.13)
(IBC 1705.14)
(IBC 1705.20)
STRUCTURAL DRAWING INDEX
SHEET
NUMBER SHEET NAME 07
/1 7/
IF
C
P A
C K
A G
E
S000 STRUCTURAL COVER SHEET ■
S001 GENERAL NOTES ■
S101 LEVEL 1 - FLOOR PLAN ■
S102 MEZZANINE - FLOOR PLAN ■
S601 WOOD FRAMING DETAILS ■
S602 WOOD FRAMING DETAILS ■
81 CRESCENT PLACE
GLENWOOD SPRINGS
COLORADO, 81601
rosenfeld-design.com
JOB NO.
SHEET NO.
TEL: 719.439.3335
ROSENFELD
D E S I G N
R
O S E N
F E
LD
D E S
IG
N
LL
C
C N
C C
Y
E A
G E R
B U
IL
D
IN
G
R A
N G
E
LY
C
O
LO
R A
D O
S000
STRUCTURAL
COVER SHEET
S000
1 3D RENDERING (FOR REFERENCE ONLY)
STRUCTURAL ABBREVIATIONS
@ AT
AB ANCHOR BOLT
ADDNL ADDITIONAL
AFF ABOVE FINISHED FLOOR
AL ALUMINUM
ALT ALTERNATE
APPROX APPROXIMATE
ARCH ARCHITECT OR ARCHITECTURAL
AVE AVERAGE
B/ OR BO BOTTOM OF
BAL BALANCE
BLDG BUILDING
BLKG BLOCK OR BLOCKING
BM BEAM
BOC BOTTOM OF CONCRETE
BOD BOTTOM OF DECK
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BASE PLATE
BRG BEARING
BTWN BETWEEN
CANT CANTILEVER
CC CENTER TO CENTER
CFMF COLD FORMED METAL FRAMING
CFMS COLD FORMED METAL STUDS
CIP CAST IN PLACE
CJ CONTROL JOINT OR CONSTRUCTION JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECT OR CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CTR(D) CENTER(ED)
DBA DEFORMED BAR ANCHOR
DBL DOUBLE
DFS DEFERRED SUBMITTAL
DIA OR Ø DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DL DEAD LOAD
DN DOWN
DP DEEP
DTL DETAIL
DWG DRAWING
DWL DOWEL
E-W EAST WEST
EA EACH
EE EACH END
EF EACH FACE
EJ EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATION OR ELEVATOR
ENGR ENGINEER
EOR ENGINEER OF RECORD
EQ EQUAL
EQUIV EQUIVALENT
ES EACH SIDE
STRUCTURAL ABBREVIATIONS
EW EACH WAY
EXIST OR (E) EXISTING
EXP EXPANSION
EXT EXTERIOR
FAB FABRICATION
FDN FOUNDATION
FF FAR FACE OR FINISHED FLOOR
FLG FLANGE
FLR FLOOR
FS FAR SIDE
FT FOOT OR FEET
FTG FOOTING
GA GAGE OR GAUGE
GALV GALVANIZED
GB GRADE BEAM
GC GENERAL CONTRACTOR
GLU-LAM GLUE LAMINATED
GR GRADE
H.A.S. HEADED ANCHOR STUD
HORIZ HORIZONTAL
HT HEIGHT
I.F. INSIDE FACE
ID INSIDE DIAMETER
IN INCH OR INCHES
INFO INFORMATION
INT INTERIOR
ISO ISOLATION
JST JOIST
JT JOINT
K KIP = 1000 LBS
LB(S) POUND(S)
LCD COMPRESSION DEVELOPMENT LENGTH
LCS COMPRESSION LAP SPLICE LENGTH
LDH HOOK DEVELOPMENT LENGTH
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LOC LOCATION
LONG. LONGITUDINAL
LSH LONG SIDE HORIZONTAL
LSL LAMINATED STRAND LUMBER
LSV LONG SIDE VERTICAL
LTD TENSION DEVELOPMENT LENGTH/CLASS A
TENSION LAP SPLICE LENGTH
LTS TENSION LAP SPLICE LENGTH (CLASS B)
LVL LAMINATED VENEER LUMBER
LWC LIGHTWEIGHT CONCRETE
MAX MAXIMUM
MECH MECHANICAL
MEP MECH/ELEC/PLUMB
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
MTL METAL
N-S NORTH SOUTH
NF NEAR FACE
NO. OR # NUMBER
NS NEAR SIDE
NTS NOT TO SCALE
NWC NORMAL-WEIGHT CONCRETE
O.F. OUTSIDE FACE
STRUCTURAL ABBREVIATIONS
OC ON CENTER
OD OUTSIDE DIAMETER
OH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OSB ORIENTED STRAND BOARD
OVS OVERSIZED
PAF POWER ACTUATED FASTENER
PC PRECAST
PCF POUNDS PER CUBIC FOOT
PE PRE-ENGINEERED
PERP PERPENDICULAR
PJP PARTIAL JOINT PENETRATION
PL PLATE
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSL PARALLEL STRAND LUMBER
PT PRESSURE TREATED
QTY QUANTITY
RE: OR REF REFER TO (REFERENCE)
REINF REINFORCED OR REINFORCING
REQD REQUIRED
REQT(s) REQUIREMENTS
RO ROUGH OPENING
ROF RANDOM ORIENTED FIBER
SCHED SCHEDULE
SECT SECTION
SIM SIMILAR
SIP STRUCTURALLY INSULATED PANEL
SLRS SEISMIC LOAD RESISTING SYSTEM
SOG SLAB-ON-GRADE
SOV SLAB-ON-VOID
SP(S) SPACE(S)
SPECS SPECIFICATIONS
SQ SQUARE
STD STANDARD
STIFF STIFFENER
STL STEEL
STR STRUCTURE OR STRUCTURAL
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T.O. OR T/ TOP OF
TBR TO BE REMOVED
THK THICK OR THICKNESS
TL TOTAL LOAD
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOPG TOPPING
TOS TOP OF STEEL
TR TRUSS
TYP TYPICAL
ULT ULTIMATE
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
W/ WITH
W/O WITHOUT
WD WOOD
WP WORK POINT
WT WEIGHT
WWF WELDED WIRE FABRIC
WWR WELDED WIRE REINFORCING
ISSUE: DATE:
IFC PACKAGE 07/17/2026
07-17-26
1. GOVERNING DESIGN CODES & STANDARDS:
A. AUTHORITY HAVING JURISDICTION: STATE OF COLORADO
B. GENERAL:
a. 2021 IBC: "INTERNATIONAL BUILDING CODE, 2021"
b. 2021 IEBC: "INTERNATIONAL EXISTING BUILDING CODE, 2021"
C. LOADS:
a. ASCE 7-16: "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES"
D. CONCRETE:
a. ACI 301-10: "SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS"
b. ACI 318-19: "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE"
E. MASONRY:
a. TMS 402-16: "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES"
b. TMS 602-16: "SPECIFICATION FOR MASONRY STRUCTURES"
F. WOOD:
a. NDS 2018: "NATIONAL DESIGN STANDARD FOR WOOD CONSTRUCTION"
01-GENERAL REQUIREMENTS
2. SPECIAL INSPECTION REQUIREMENTS AND QUALITY CONTROL:
A. SEE "STATEMENT OF SPECIAL INSPECTIONS" FOLLOWING GENERAL NOTES FOR INSPECTION REQUIREMENTS.
4. BUILDING CONSTRUCTION INFORMATION:
A. BUILDING CONSTRUCTION TYPE: TYPE V
2. POST-INSTALLED ANCHORS INTO CONCRETE:
A. PROVIDE POST-INSTALLED, CONCRETE ANCHORS AS SHOWN IN THE CONTRACT DOCUMENTS AND IN THE
SPECIFICATIONS.
B. ANCHORS SUPPORTING NON-FIREPROOFED STRUCTURAL FRAMING. ANCHOR INSTALLATION SHALL BE
INSPECTED IN ACCORDANCE WITH THE REQUIREMENTS FOR SPECIAL INSPECTIONS. ANCHORS SHALL BE ONE
OF THE FOLLOWING AS INDICATED ON PLANS AND DETAILS:
a. HILTI HDA UNDERCUT OR KWIK BOLT TZ ANCHORS
b. SIMPSON TORQ-CUT OR STRONG-BOLT 2 ANCHORS
c. DEWALT CCU+ UNDERCUT OR POWER-STUD+ SD1
d. RED HEAD TRUBOLT+ WEDGE ANCHOR BY ITW
C. ANCHORS SUPPORTING MISCELLANEOUS FRAMING SHALL BE AS SHOWN IN THE PLANS AND DETAILS. IF NOT
OTHERWISE SPECIFIED, THE ANCHORS SHALL BE ONE OF THE FOLLOWING:
a. HILTI KWIK BOLT TZ
b. SIMPSON STRONG-BOLT 2
c. DEWALT POWER-STUD+ SD1
d. RED HEAD TRUBOLT+ WEDGE ANCHOR BY ITW
D. ANCHORS SUPPORTING ARCHITECTURAL COMPONENTS, ELECTRICAL AND MECHANICAL EQUIPMENT SHALL BE
ONE OF THE FOLLOWING AS INDICATED ON PLANS AND DETAILS:
a. HILTI HDI
b. SIMPSON DROP-IN
c. DEWALT SNAKE+
d. RED HEAD MULTI-SET II DROP IN.
E. ANCHORS ATTACHING LIGHT-GAGE STEEL FRAMING TO CONCRETE SHALL BE ONE OF THE FOLLOWING AS
INDICATED ON PLANS AND DETAILS:
a. HILTI LOW-VELOCITY X-U UNIVERSAL POWDER DRIVEN TRACK FASTENERS
b. SIMPSON PDPA POWDER DRIVEN FASTENERS
c. DEWALT CSI SPIRAL DRIVE PINS
d. RAMSET TRUE EMBEDMENT (TE) POWER DRIVEN FASTENER
F. PRIOR TO ANCHOR INSTALLATION, LOCATE EXISTING REINFORCING WITHIN CONCRETE SUBSTRATE. DO NOT DAMAGE EXISTING REINFORCING DURING INSTALLATION. CONTACT THE STRUCTURAL ENGINEER IF ANCHOR
LOCATION CONFLICTS WITH EXISTING REINFORCING.
G. PRODUCT SUBSTITUTION: THE CONTRACTOR MAY SUBMIT ALTERNATE ANCHORS FOR REVIEW AND APPROVAL PROVIDED THE ACCOMPANYING PRODUCT DATA IS SATISFACTORY TO THE ENGINEER FOR
COMPARISON TO THE SPECIFIED ANCHORS.
1. COORDINATION:
A. THE STRUCTURAL DRAWINGS ILLUSTRATE AND DESCRIBE THE COMPLETED STRUCTURE WITH ELEMENTS
IN THEIR FINAL POSITIONS, PROPERLY SUPPORTED, CONNECTED, AND/OR BRACED.
B. THE STRUCTURAL DRAWINGS ILLUSTRATE TYPICAL AND REPRESENTATIVE DETAILS TO ASSIST THE
GENERAL CONTRACTOR. DETAILS SHOWN APPLY AT ALL SIMILAR CONDITIONS UNLESS OTHERWISE INDICATED. ALTHOUGH DUE DILIGENCE HAS BEEN APPLIED TO MAKE THE DRAWINGS AS COMPLETE AS POSSIBLE, NOT EVERY DETAIL IS ILLUSTRATED AND NOT EVERY EXCEPTIONAL CONDITION IS ADDRESSED.
C. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL WORK, INCLUDING LAYOUT AND DIMENSION VERIFICATION, MATERIALS COORDINATION, SHOP DRAWING REVIEW, AND THE WORK OF SUBCONTRACTORS. ANY DISCREPANCIES OR OMISSIONS DISCOVERED IN THE COURSE OF THE WORK SHALL BE IMMEDIATELY REPORTED TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR RESOLUTION.
CONTINUATION OF WORK WITHOUT NOTIFICATION OF DISCREPANCIES RELIEVES THE ARCHITECT AND
STRUCTURAL ENGINEER FROM ALL CONSEQUENCES.
D. UNLESS OTHERWISE SPECIFICALLY INDICATED, THE STRUCTURAL DRAWINGS DO NOT DESCRIBE
METHODS OF CONSTRUCTION.
E. CONFLICTS WITHIN THE STRUCTURAL DRAWINGS SHALL BE REPORTED TO THE STRUCTURAL ENGINEER
FOR RESOLUTION BEFORE PROCEEDING WITH MODIFICATIONS OR ADJUSTMENT.
F. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE MECHANICAL AND ELECTRICAL EQUIPMENT PURCHASED WITH INFORMATION SHOWN ON THE STRUCTURAL DRAWINGS INCLUDING, BUT NOT LIMITED
TO, EQUIPMENT LOCATION, SIZE, WEIGHT, OPENINGS AND SUPPORT REQUIREMENTS. REPORT
DIFFERENCES TO THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH THE WORK.
G. EXISTING CONDITIONS: THE STRUCTURAL DRAWINGS HAVE BEEN PREPARED USING AVAILABLE INFORMATION OF EXISTING CONDITIONS. NO ATTEMPT HAS BEEN MADE TO VERIFY EXISTING CONDITIONS AGAINST INFORMATION RECEIVED FROM THE CLIENT OR OTHER SOURCES. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPARE THE EXISTING CONDITIONS TO THE INFORMATION SHOWN ON THE DRAWINGS AND NOTIFY THE ARCHITECT OF ANY DIFFERENCES BEFORE PROCEEDING WITH THE WORK.
2. SUBSTITUTIONS:
A. SUBSTITUTIONS ARE NOT ALLOWED WITHOUT APPROVAL FROM THE ARCHITECT AND STRUCTURAL ENGINEER. REQUEST FOR SUBSTITUTION MUST BE ACCOMPANIED BY PROPER INFORMATION NECESSARY TO EVALUATE THE SUBSTITUTION AND COMPENSATION FROM THE CONTRACTOR MAY BE REQUIRED TO
CONDUCT THE EVALUATION PROCESS.
3. REQUIRED SUBMITTALS:
A. SUBMIT SHOP DRAWINGS, CALCULATIONS, PRODUCT DATA AND OTHER PERTINENT INFORMATION FOR THE
FOLLOWING ITEMS FOR REVIEW BY THE ARCHITECT AND ENGINEER. WORK SHALL NOT PROCEED UNTIL ALL SUBMITTALS RELATED TO THE WORK HAVE BEEN REVIEWED AND ACCEPTED. THE CONTRACTOR SHALL SUBMIT COPIES OF ALL SUBMITTALS TO THE BUILDING DEPARTMENT AFTER REVIEW BY THE ARCHITECT
AND/OR ENGINEER OF RECORD WHEN REQUIRED.
a. PRODUCT DATA
22, 23, 26-MECHANICAL AND ELECTRICAL TRADES
1. PRECEDENCE:
A. STRUCTURAL FRAMING COMPONENTS, INCLUDING BUT NOT LIMITED TO WOOD FRAMING, CONCRETE
FRAMING, REINFORCING AND EMBEDMENTS SHALL TAKE PRECEDENCE OVER MECHANICAL, PLUMBING
AND ELECTRICAL (MEP) ITEMS.
B. STRUCTURAL FRAMING COMPONENTS SHALL NOT BE MOVED, ADJUSTED OR OTHERWISE MODIFIED FROM THE STRUCTURAL DRAWINGS TO ACCOMMODATE OTHER DISCIPLINES WITHOUT APPROVAL FROM THE
STRUCTURAL ENGINEER.
2. COORDINATION:
A. THE GENERAL CONTRACTOR AND MECHANICAL AND ELECTRICAL SUBCONTRACTORS SHALL VERIFY
PURCHASED EQUIPMENT AND REQUIRED OPENINGS THROUGH FLOORS, ROOF AND WALLS ARE IN
AGREEMENT WITH THE DESIGN INFORMATION SHOWN ON THE DRAWINGS.
B. DIFFERENCES OR CONFLICTS BETWEEN THE DRAWINGS AND MECHANICAL AND ELECTRICAL
REQUIREMENTS SHALL BE REPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.
C. PENETRATIONS: THE GENERAL CONTRACTOR SHALL SUBMIT COORDINATED AND DIMENSIONED
DRAWINGS SHOWING ALL MECHANICAL, PLUMBING AND ELECTRICAL PENETRATIONS FOR REVIEW AND
APPROVAL AT LEAST THREE WEEKS PRIOR TO STARTING THE WORK..
3. SUPPORT OF EQUIPMENT:
A. SUPPORT OF MECHANICAL, PLUMBING AND ELECTRICAL ITEMS SUSPENDED FROM WOOD FRAMED FLOOR
AND ROOF, INCLUDING DETERMINATION OF NUMBER AND POSITION OF FASTENERS, IS THE
RESPONSIBILITY OF THE CONTRACTOR.
ZONE
ROOF ZONES
WIND
SUCTION
WIND
PRESSURE
16.0
PSF
NOTES:
1. PRESSURES LISTED ABOVE ARE ULTIMATE IN ACCORDANCE WITH ASCE 7.
2. VALUES ARE CALCULATED IN ACCORDANCE WITH "PART 1" IN CHAPTER 30.2 OF ASCE 7: "LOW-RISE
BUILDINGS WITH H<60FT, FOR ENCLOSED OR PARTIALLY ENCLOSED BUILDINGS".
3. REFER TO ASCE 7, FIGURES 30.3-1 THROUGH 30.3-8 FOR DEFINITION OF ZONES.
4. VALUES ARE FOR EFFECTIVE WIND AREAS OF 10 SQUARE FEET OR LESS. VALUES MAY BE REDUCED FOR
AREAS GREATER THAN 10 SQUARE FEET IN ACCORDANCE WITH PROCEDURES GIVEN IN ASCE 7.
5. VALUES WERE DETERMINED AT A MEAN ROOF HEIGHT OF 118.5 FT. WIND PRESSURE VALUES MAY BE
REDUCED FOR COMPONENTS AT LOWER ELEVATIONS IN ACCORDANCE WITH PROCEDURES GIVEN IN
ASCE 7.
6. DESIGNED FOR BASE PRESSURE, qh = ± 28.4 PSF, 'a' = 8.0 FT.
7. PRESSURE INDICATES LOAD ACTING TOWARDS SURFACES. SUCTION INDICATES LOAD ACTING AWAY
FROM SURFACES.
8. COMPONENTS AND CLADDING SHALL BE DESIGNED FOR MAXIMUM PRESSURE AND SUCTION ACTING
INDEPENDENTLY.
-44.8
PSF
1' 2 2e 2n 2r 3 3e 3r
LOCATION
4 5
WALL ZONES
N/A 16.0
PSF
-70.3
PSF
16.0
PSF
-95.9
PSF
30.6
PSF
-30.6
PSF
30.6
PSF
-56.1
PSF
EXPLANATION OF SECTION DIAGRAM USED (PLAN SHEET)
EXPLANATION OF SECTION DIAGRAM USED (DETAIL SHEET)
SECTION IDENTIFICATION
STRUCTURAL SHEET WHERE
SECTION IS DRAWN
SECTION IDENTIFICATIONSTRUCTURAL SHEET WHERE
SECTION IS FIRST CUT
STRUCTURAL SHEET WHERE
SECTION IS DRAWN
8. PRECAUTIONARY NOTES ON STRUCTURAL BEHAVIOR:
A. INTERIOR ARCHITECTURAL FINISH DETAILING MUST ACCOMMODATE THE RELATIVE DIFFERENTIAL
MOVEMENTS OF SUPPORTING STRUCTURAL ELEMENTS.
B. WHERE THE ROOF FRAMING ELEMENT SPANS ARE LONG, APPLIED LOADING WILL NATURALLY CAUSE
SUBSTANTIAL DEFLECTION. INTERIOR ELEMENTS HUNG FROM THE ROOF STRUCTURE WILL DEFLECT WITH
THE ROOF.
C. THE FLOOR IS A FLOATING CONCRETE SLAB-ON-GRADE AND MAY EXPERIENCE MOVEMENTS INDEPENDENT OF THE STRUCTURAL FOUNDATIONS. INTERIOR ELEMENTS SUPPORTED ON THE SLAB-ON-GRADE FLOOR WILL
MOVE WITH THE FLOOR. INTERIOR ELEMENTS SUPPORTED ON FOUNDATIONS AND COLUMNS WILL NOT
EXPERIENCE SIMILAR OR MEASURABLE MOVEMENTS.
D. EXTERIOR/PERIMETER WALL ASSEMBLIES HUNG FROM THE EDGE OF THE BUILDING STRUCTURE WILL BE
DIRECTLY AFFECTED (TO SOME DEGREE) BY CHANGES IN EXTERNAL TEMPERATURE AND FLOOR DEFLECTION.
E. EXTERIOR/PERIMETER AND INTERIOR ARCHITECTURAL FINISH DETAILS SHOULD ALLOW FOR RELATIVE
MOVEMENTS BETWEEN ELEMENTS WITH DIFFERENT SUPPORT CONDITIONS.
B. DESCRIPTION OF EXISTING LATERAL LOAD-RESISTING SYSTEM:
a. THE LATERAL LOAD-RESISTING ELEMENTS THAT PROVIDE LATERAL STRENGTH AND STABILITY OF THE
COMPLETED STRUCTURE ARE AS FOLLOWS:
• LIGHT-FRAMED (WOOD) SHEAR WALLS SHEATHED WITH WOOD STRUCTURAL PANELS.
b. THE DIAPHRAGM ELEMENTS WITHIN THE LATERAL LOAD-RESISTING SYSTEM ARE AS FOLLOWS:
• WOOD ROOF AND FLOOR SHEATHING, INCLUDING THE CONNECTIONS TO LATERAL LOAD-RESISTING
ELEMENTS.
c. SEE DETAILS FOR SPECIAL ERECTION CONSIDERATIONS AND LATERAL LOAD-RESISTING SYSTEM
COMPONENTS NOT LISTED HERE.
d. TEMPORARY BRACING: DURING BUILDING ERECTION, THE STEEL ERECTOR SHALL DETERMINE, FURNISH AND INSTALL ALL TEMPORARY SUPPORTS AND BRACING NECESSARY FOR LATERAL STABILITY OF THE SUPERSTRUCTURE UNTIL THE LATERAL LOAD-RESISTING ELEMENTS AND DIAPHRAGMS ARE IN
PLACE AND ALL CONNECTIONS ARE COMPLETE.
5. DESIGN LOAD CRITERIA
A. DEAD LOAD (EXISTING ROOF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 PSF (ASSUMED) B. DEAD LOAD (EXISTING MEZZANINE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 PSF (ASSUMED) C. FLOOR LIVE LOADS (EXISTING MEZZANINE) . . . . . . . . . . . . . . . . . . . . . . 125 PSF (NON-REDUCIBLE) D. ROOF LIVE LOADS . . . . . . . . . . . . . . . . . . . . . . . SEE SNOW AND WIND LOADS BELOW (20 PSF MIN) E. RISK CATEGORY (IBC 1604.5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . III - INCREASED RISK
F. SNOW LOADS
a. GROUND SNOW LOAD, Pg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35.5 PSF
b. FLAT ROOF SNOW LOAD, Pf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40.0 PSF
c. SNOW EXPOSURE FACTOR, Ce . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.9
d. SNOW LOAD IMPORTANCE FACTOR, IS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1
e. THERMAL FACTOR, Ct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1
G. SEISMIC LOADS:
a. SEISMIC IMPORTANCE FACTOR, IE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.25
b. SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.308
c. S1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.075
d. SITE CLASS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D (ASSUMED)
e. SDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.319
f. SD1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.12
g. SEISMIC DESIGN CATEGORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B
h. DESIGN SEISMIC FORCE RESISTING SYSTEM (S):
• LIGHT-FRAMED (WOOD) SHEAR WALLS SHEATHED WITH WOOD STRUCTURAL PANELS RATED FOR
SHEAR RESISTANCE. (R=6.5)
i. DESIGN BASE SHEAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.9 KIPS
j. SEISMIC RESPONSE COEFFICIENT, CS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.032
k. RESPONSE MODIFICATION FACTOR, R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5
l. OVERSTRENGTH FACTOR, ΩO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5
m. DEFLECTION AMPLIFICATION FACTOR, Cd
n. ANALYSIS PROCEDURE USED . . . . . . . . . . . . EQUIVALENT LATERAL FORCE ANALYSIS (ASCE-7 12.8)
H. RAIN LOADS:
a. RETURN PERIOD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 YEAR
b. ONE-HOUR RAINFALL INTENSITY, i60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.32 IN/HR
c. 15-MINUTE RAINFALL INTENSITY, i15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.51 IN/HR
d. TOTAL RAIN LOAD, R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27.5 PSF
I. WIND LOADS:
a. BASIC ULTIMATE WIND SPEED, VULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 MPH
b. BASIC NOMINAL WIND SPEED, VASD . . . . . . . . . . . . . . . . . . .