This is a specification document from the Department of Transportation (RFP Dept. 591, No. 220000001069) detailing requirements for a Trailer Mounted Attenuator with a collapsible frame type and arrow board sign. The specification requires contractors to furnish new, latest-model equipment that meets NCHRP 350 TL3 safety standards. The attenuator system must include an impact frame equipped with Torflex heavy-duty axles, wheels, tires, safety chains, and a 3-inch pintle hitch rated for crash performance. The unit requires LED lighting compliant with FMVSS 108 standards, including brake, tail, ICC bar, and turn signals, along with two synchronized flush-mount amber/green LED strobe lights. The specification mandates an integrated arrow sign board measuring 48 inches high by 96 inches wide with aluminum welded construction, featuring 15 replaceable Par 46 LED arrow lamps and a solid-state controller with LED display. Physical specifications include a maximum height of 45 inches, width of 7 feet 9 inches, length of 23 feet 2 inches, and weight of 1,300 pounds, with a galvanized finish and welding performed by certified welders.

The specification requires the attenuator to pass all NCHRP 350 TL3 performance tests (TL3-50 through TL3-54) and an accelerated endurance test simulating actual use conditions. The arrow board must operate at approximately 146 inches in height and collapse to approximately 88 inches for transport, with power supplied from the towing vehicle supplemented by a 55-watt solar panel with 4-amp regulator connected to a 12-volt marine battery. All electrical connections must be soldered and enclosed in heat shrink or watertight junction blocks, with wiring routed in protective jacketed cables and secured at 18-inch intervals. The specification mandates conspicuity tape and reflectors compliant with NHTSA and SAE standards, a hand-crank jack with 600-pound minimum capacity, and all metalwork to be made in America. Contractors must respond with "YES" to each specification section or provide detailed explanations and available options for any deviations.

View the file

Other files

File Type Posted
C68-0001AM.22 Truck Mounted Attenuator A6.xlsx XLSX spreadsheet
Schedule A.docx DOCX document
Standard Contract Terms.docx DOCX document
C68-0501.22 Trailer Mounted Attenuator A3.xlsx XLSX spreadsheet
C68-0001A.22 Truck Mounted Attenuator A2.xlsx XLSX spreadsheet
C68-0001M.22 Truck Mounted Attenuator A5.xlsx XLSX spreadsheet
Schedule B Pricing.xlsx XLSX spreadsheet
RFP Instructions.docx DOCX document
C68-0001.22 Truck Mounted Attenuator A1.xlsx XLSX spreadsheet
C68-0501M.22 Trailer Mounted Attenuator A7.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

RFP Dept. 591, No. 220000001069
Specification # C68-0501A.22 Trailer Mounted Attenuator, Collapsible Frame Type with Arrow Board Sign Meeting NCHRP 350 TL3 Standards

All items specified and furnished by the Contractor shall be new of the latest model in current production and shall include all standard features normally offered with these models CONTRACTOR must respond to each section with YES. (or additional information as requested)

If NO is indicated provide explanation and available option.

Contract to identify proposed make and model
Brands or trade names are for identification purposes only and do not limit the Contractor to such brandsMake and Model
1.0Basic Requirements:
1.1All wires passing through holes in metal or non-metal wearing surfaces, which could cause wear of the insulation, shall be adequately protected by rubber or plastic grommets, and/or non-metal conduit. Ends of all wires shall be adequately anchored to prevent loosening. All wiring shall be properly secured to the unit by proper wiring hangers.
1.2Ends of all wires shall be adequately anchored to prevent loosening
1.3All electrical connections shall be soldered and enclosed in heat shrink or in water tight junction blocks
1.4Scotch locks and wire nuts are not acceptable
1.5Unit number will be provided and shall be welded to the unit in 2 inch high numbers or welded or stamped to a plate and bolted to the unit
1.6Trailer mounted attenuator system can be used with any weight over 9,920 pounds
1.7The attenuator frame shall be capable of collapsing when impacted by an errant vehicle
1.8No portion of the attenuator shall protrude forward under the truck damaging its vital elements during an impact
1.9Attenuator shall not impede the line-of-sight of an arrow board or message board mounted on the truck installed per MUTCD (Manual on Uniform Traffic Control Devices) guide lines at a height of 7 feet to the bottom of the board
2.0Following a design impact under NCHRP TL-3 conditions, the attenuator shall remain less than 12 feet wide and retain its structure to permit short distance transport off of the road after impact
2.1Trailer mounted attenuator shall consist of the following components:
aImpact frame
bShall be equipped Torflex heavy duty, axle, wheels, tires
cShall be equipped with safety chains and a 3 inch pintle hitch rated to meet the crash rating of the unit
2.2Attenuator shall have a standard trailer lighting system compliant with FMVSS 108 standards, wired for turn signals independent of stop lights
2.3Lighting system shall include brake, tail, ICC bar, and turn signals that are LED type
2.4Wiring for the rear lights shall be routed in a protective jacketed cable
2.5Wiring cable shall be routed and secured to the frame at 18 inch interval maximum
2.6Molded electrical connectors shall be used where individual wires would other wise be exposed to the elements
2.7Light connector shall be round 7 pin Berg type
2.8Light connector wired to MDOT specifications
2.9Two (2) flush mount strobe lights which are synchronized shall be provided in the rear strike plate, lights shall be an amber/green LED combination light. Flash pattern is to be set to the following pattern, Amber - Quad fast flash, Green - Single slow flash. 4" round Whelen # 2EP00ZCRMDOT, Oval # 50AG2ZCRMDOT or equivalent
3.0Conspicuity tape and reflectors shall be installed in compliance with all applicable NHTSA, FMVSS and SAE Standards
3.1One (1) hand crank jack with swivel caster having a rated load capacity of 600 pounds minimum shall be provided
3.2Rear strike facing surface of the frame assembly shall display a black on yellow inverted "V" chevron pattern with a 4" wide color bands when in the horizontal position
3.3All welding shall be done by, or under the direction of a certified welder
3.4Metal work shall be made in America
3.5Unit shall properly cleaned and prepped and have a galvanized finish
3.6Maximum height from ground shall be 45 inches
3.7Maximum width of impact face shall be 7 feet 9 inches
3.8Weight shall be 1300 pounds
3.9Length shall be 23 feet 2 inches
4.0Hitch extension adaptor kit
4.1Attenuator shall have the following performance criteria:
4.2Attenuator shall have passed all tests required under NCHRP 350 TL 3-50
4.3Attenuator shall have passed all tests required under NCHRP 350 TL 3-51
4.4Attenuator shall have passed all tests required under NCHRP 350 TL 3-52
4.5Attenuator shall have passed all tests required under NCHRP 350 TL 3-53
4.6Attenuator shall have passed all tests required under NCHRP 350 TL 3-54
4.7The Attenuator shall be capable of passing an accelerated endurance test, which duplicates anticipated shock loading the system may encounter in actual use.
4.8ARROW SIGN BOARD
4.9Sign board shall be aluminum construction, welded frame 48 inch's high x 96 inches wide with flat black finish.
5.0Arrow board shall be a manual tilt design with a worm gear and crank assembly to raise and lower the board
5.115 replaceable lamps shall be Par 46 LED arrow lamps
5.2Controller shall be solid state design, capable of simultaneous or sequential arrow with caution modes
5.3Controller shall have LED display illustrating exact message mode arrow board will display
5.4Controller shall be fully enclosed, sealed, hinged lid, lockable with padlock and mounted on the curb side of trailer
5.5All connections shall be quick connect weatherproof design
5.6Operating height of sign shall be approximately 146 inches
5.7Travel height shall be approximately 88 inches
5.8Power for the arrow shall be from the towing vehicle
5.9Arrow board shall be equipped with a 55 watt solar panel equipped with a 4 amp regulator, wired to connect to a 12 volt marine application battery
6.0Unit shall be equipped with a marine battery box and steel enclosure, lockable with a padlock
END OF SPECIFICATION