This is a clarifying questions response document from Clackamas County Water Environment Services regarding BID #2025-83 for the Kellogg Creek Water Resource Recovery Facility (WRRF) Administration Building Remodel project. The document addresses a technical question submitted by interested bidders regarding corrupted PDF files in the solicitation plans, specifically sheets P000 and M000. The Owner and Architect confirmed that corrected copies of these sheets were attached to the clarifying questions response and are identical to those in the current bid set. The rendering issues with sheets P000 and M000 appear to stem from software compatibility problems, as the documents display correctly in Bluebeam (the primary software used by the Owner and Architect) but may not render properly in Adobe Acrobat. The clarifying questions response was issued on January 12, 2026, providing bidders with access to the necessary plan documents ahead of the sealed bid deadline.
The document is primarily composed of the general notes, symbols, and specification details from the mechanical and plumbing drawing sheets (M000 and P000). These sheets contain comprehensive abbreviations, symbols, demolition notes, and general installation requirements for HVAC and plumbing systems, including coordination requirements with all trades, penetration and firestopping standards, and field verification protocols. The mechanical section outlines a complete list of plumbing and HVAC drawing sheets organized by location and system type, while both sections emphasize contractor responsibility for coordinating work, verifying existing conditions, complying with state and local codes, and ensuring proper installation per manufacturer recommendations. No pricing information, funding sources, or award details are contained within this clarifying questions response document.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INVITATION TO BID #2025-83
Kellogg Creek WRRF Administration Building Remodel (“BID”)
RESPONSE TO CLARIFYING QUESTIONS
January 12, 2026
Note that these are questions submitted by interested firms to the above referenced solicitation.
The below answers are for clarification purposes only and in no way alter or amend the BID as published.
1. We have downloaded the Plans and specifications, however there are two pages in the solicitation plans that seem to be corrupted and cannot be printed. Could you please send over plan pages POOO (72) and MOOO (87)?
Answer: Copies of sheets P000 and M000 are attached to this Clarifying Questions #2.
These sheets are identical to those in the current bid set. The issues reported may be due to software compatibility. While PDF is a standard format, different programs can render files differently. The Owner and Architect primarily use Bluebeam and have not encountered issues. However, we have confirmed that these specific sheets may not display correctly when using Adobe Acrobat.
End of Clarifying Questions
CONTACT 811 BEFORE YOU DIG:
UNDERGROUND FACILITIES, STRUCTURES, AND UTILITIES HAVE BEEN SHOWN BASED UPON INFORMATION OBTAINED FROM FIELD LOCATIONS BY UTILITY COMPANIES, AVAILABLE SURVEYS AND RECORDS. THEIR LOCATIONS MUST BE CONSIDERED APPROXIMATE ONLY. IT IS ALSO POSSIBLE THAT THERE MAY BE OTHER UNDERGROUND FACILITIES, STRUCTURES, AND UTILITIES IN EXISTENCE THAT ARE NOT SHOWN. IT IS THE RESPONSIBILITY OF EACH INDIVIDUAL PARTY REFERENCING THIS PLAN TO DETERMINE THE EXACT LOCATION AND TYPE OF UNDERGROUND FACILITIES ON THE SITE. HAND EXCAVATE AT CRITICAL POINTS AS NECESSARY TO VERIFY LOCATIONS, SIZES, ELEVATIONS, FLOW LINES, ETC. IF A PROBLEM OR INTERFERENCE EXISTS, NOTIFY ARCHITECT/ENGINEER BEFORE PROCEEDING.
HVAC ABBREVIATIONS
ABSORP ABSORPTION FPS FEET PER SECOND
ACU AIR CONDITIONING UNIT FSEC FOOD SERVICE EQUIP. CONSULT.
AD ACCESS DOOR OR AREA DRAIN FT FINTUBE
AFF ABOVE FINISHED FLOOR FTG FOOTING
AFG ABOVE FINISHED GRADE GA GAGE
AHU AIR HANDLING UNIT GAL GALLON
AV AIR VENT GALV GALVANAIZED
BOP BOTTOM OF PIPE GC GENERAL CONTRACTOR
BOT BOTTOM GPH GALLONS PER HOUR
BTU BRITISH THERMAL UNIT GPM GALLONS PER MINUTE
BTUH BUT PER HOUR HR HOUR
BV BALL VALVE HTG HEATING
CA COMPRESSED AIR ISP INTERNAL STATIC PRESSURE
CENT CENTRIFUGAL JR JANITOR RECEPTOR
CFM CUBIC FEET PER MINUTE LDBT LEAVING DRY BULB TEMP.
CL CENTER LINE LWBT LEAVING WET BULB TEMP.
CONC CONCRETE LWT LEAVING WATER TEMPERATURE
COND CONDENSATE MBH 1000 BTUH
CONTR CONTRACTOR MC MECHANICAL CONTRACTOR
CP CONDENSATE PUMP MECH MECHANICAL
CU COPPER MH MANHOLE
CUH CABINET UNIT HEATER NTS NOT TO SCALE
DDC DIRECT DIGITAL CONTROLS OA OUTSIDE AIR
DN DOWN PC PLUMBING CONTRACTOR
EA EXHAUST AIR PRV PRESSURE REDUCING VALVE
EAT EXHAUST AIR TEMPERATURE PRV POWER ROOF VENTILATOR
EC ELECTRICAL CONTRACTOR PSI POUNDS PER SQUARE INCH
EDBT ENTERING DRY BULB TEMP. PV PRESSURE VENT
EF EXHAUST FAN PVC POLYVINYL CHLORIDE
EJ EXPANSION JOINT RA RETURN AIR
EQUIP EQUIPMENT RH RELATIVE HUMIDITY
EST EXTERNAL STATIC PRESSURE RTU ROOF TOP UNIT
EWBT ENTERING WET BULB TEMP. RV RELIEF VALVE
EWT ENTERING WATER TEMPERATURE RVT ROOF VENT TERMINATION
EX EXISTING SA SUPPLY AIR
EXH EXHAUST
TCC TEMP. CONTROL CONTRACTOREXP EXPANSION
TYP TYPICALFAI FRESH AIR INTAKE
UH UNIT HEATERFCU FAN COIL UNIT
UV UNIT VENTILATORFDC FIRE DEPRARTMENT CONNECTION
VA VENTILATION AIRFLEX FLEXIBLE
WB WALL BOX - CONDENSATEFPM FEET PER MINUTE
ELEMENT PHASE ABBREVIATIONS
(E) EXISTING ITEM TO REMAIN
(ER) NEW LOCATION OF EXISTING ITEM
(N) NEW ITEM IN EXISTING LOCATION
(R) EXISTING ITEM TO BE REMOVED, PATCH AND/OR COVER
(RN) REPLACE EXISTING ITEM WITH NEW
(RR) EXISTING ITEM TO BE REMOVED AND RELOCATED
TA TRANSFER AIR
HVAC DEMOLITION NOTES:
1. MECHANICAL DEMOLITION DRAWINGS SHOWING EXISTING CONDITIONS HAVE BEEN PREPARED BASED ON NON- DESTRUCTIVE SITE OBSERVATIONS AND AS-BUILT DOCUMENTS PROVIDED BY THE OWNER. CONTRACTOR TO FIELD VERIFY EXISTING SYSTEMS PRIOR TO BEGINNING WORK. NOTIFY ARCHITECT/ENGINEER IF EXISTING CONDITIONS
ARE MATERIALLY DIFFERENT THAN THOSE SHOWN ON THE DRAWINGS.
2. BE FAMILIAR WITH EXISTING MECHANICAL SYSTEMS THAT WILL BE AFFECTED BY THE DEMOLITION WORK. OBTAIN PERMISSION FROM THE OWNER'S REPRESENTATIVE TO SHUT OFF SERVICES OR SYSTEMS THAT AFFECT AREAS BEYOND THE LIMITS OF THE IMMEDIATE DEMOLITION AREA. INFORM THE OWNER'S REPRESENTATIVE OF THE REASON FOR AND DURATION OF THE SHUTDOWN. MINIMIZE IMPACT TO OTHER AREAS. PROCEED WITH THE
SHUTDOWN AFTER PERMISSION FROM THE OWNER IS GRANTED.
3. REMOVE DUCTWORK, PIPING, HANGERS, GRILLES, REGISTERS, DIFFUSERS, ETC. THAT ARE INDICATED TO BE REMOVED. PERFORM WORK IN A TIMELY MANNER AND IN ACCORDANCE WITH THE GENERAL DEMOLITION
SPECIFICATIONS. COORDINATE WITH THE OWNER AND OTHER CONTRACTORS.
4. UNLESS EQUIPMENT NOTED AS OWNER'S SALVAGE, DISPOSE OF REMOVED EQUIPMENT AND MATERIALS PROMPTLY.
5. REMOVE ALL ABONDONED PIPING AND DUCTWORK THAT IS EXPOSED OR ACCESSIBLE WITHOUT WALL OR CEILING
DEMOLITION. REFER TO ARCHITECTURAL PLANS FOR CEILINGS TO BE REMOVED.
HVAC GENERAL NOTES:
1. COORDINATE HVAC WORK WITH ALL OTHER TRADES. BEGIN INSTALLATION AND ROUGH-IN AFTER COORDINATION WITH ALL TRADES ASSOCIATED WITH PROJECT SCOPE. COORDINATE HVAC SYSTEMS INSTALLATION WITH BUILDING STRUCTURE, ARCHITECTURAL ASSEMBLIES, SHEET METAL, PIPING SYSTEMS, LIGHTING FIXTURES, CONDUITS, CABLE TRAYS, ETC. REFER TO ALL GENERAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT. CONTRACTOR IS RESPONSIBLE FOR REWORK ASSOCIATED WITH FAILURE TO COORDINATE.
2. PROVIDE A COMPLETE HVAC SYSTEM INCLUDING SUPPLY, RETURN, EXHAUST, AND VENTILATION DUCTWORK;
MECHANICAL EQUIPMENT, SUPPORTS, HANGERS, DIFFUSERS, GRILLES, REGISTERS AND ALL APPURTENANCES.
INSTALL ALL EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. SIZING AND INSTALLATION OF HVAC
SYSTEMS TO MEET ALL STATE AND LOCAL CODES AND PROJECT REQUIREMENTS.
3. DRAWING PLANS, SCHEMATICS AND DIAGRAMS INDICATE GENERAL LOCATION AND ARRANGEMENT OF DUCT SYSTEM. INDICATED DUCT LOCATIONS, CONFIGURATIONS AND ARRANGEMENTS WERE USED FOR DUCT SIZING, CALCULATING FRICTION LOSS AND FOR OTHER DESIGN CONSIDERATIONS. INSTALL DUCT SYSTEMS AS INDICATED
UNLESS DEVIATIONS TO LAYOUT ARE APPROVED BY ARCHITECT/ENGINEER.
4. INCORPORATE MECHANICAL DRAWINGS, SPECIFICATIONS, STATE AND LOCAL CODES, AND PROJECT STANDARDS
INTO WORK.
5. ALL DUCT DIMENSIONS INDICATED ARE INTERIOR FREE AREA DUCT DIMENSIONS AND DO NOT INCLUDE INSULATION
REQUIREMENTS.
6. CONTRACTOR IS RESPONSIBLE FOR MAKING PENETRATIONS WHERE REQUIRED IN EXISTING WALLS, FLOORS, CEILINGS AND ROOFS. MAKE PENETRATIONS NEAT. PATCH, CONCEAL OR CAULK ALL OVERCUT TO PREVENT NOISE TRANSFER BETWEEN SPACES. COVER EXPOSED WALL PENETRATIONS WITH ESCUTCHEONS OR SHEET METAL AS
APPROPRIATE. SEAL ALL WALL AND FLOOR DUCT PENETRATIONS.
7. REFER TO ARCHITECTURAL SPECIFICATIONS FOR THROUGH-PENETRATION FIRESTOPPING AND TO ARCHITECTURAL CODE PLAN FOR FIRE RATED WALLS, FLOORS AND CEILINGS. CONTRACTOR IS RESPONSIBLE TO FIRESTOP PENETRATIONS THROUGH RATED ASSEMBLIES. PROVIDE FIRE CAULKING FOR PENETRATIONS OF FIRE RATED
ASSEMBLIES.
8. CONTINUE DUCT AND PIPE INSULATION UNBROKEN THROUGH WALLS, FLOORS AND CEILING PENETRATIONS, EXCEPT WHERE FIRE OR FIRE/SMOKE DAMPERS ARE INSTALLED IN DUCTWORK. SEAL AROUND DUCT INSULATION
AT WALL PENETRATIONS.
9. CREATE OPENINGS IN BUILDING AS REQUIRED TO REMOVE EXISTING BUILDING COMPONENTS AND BRING IN NEW EQUIPMENT. PATCH ALL OPENINGS CREATED. PATCH FINISH TO MATCH EXISTING CONDITIONS. INCLUDE THIS
WORK IN BID.
XXX
GENERAL SYMBOLS
EQUIPMENT IDENTIFICATION
KEYNOTE
POINT OF DISCONNECT
NEW POINT OF CONNECTION
DEMOLITION LINEWORK TO BE SHOWN AS BOLD DASHED AND BLACK
NEW LINEWORK TO BE SHOWN AS BOLD AND BLACK
EXISTING LINEWORK TO BE SHOWN AS "HALFTONE"
HIDDEN LINEWORK TO BE SHOWN AS THIN DASHED AND BLACK
HVAC SYMBOLS
RECT. RND. OVAL
10x6 SA
10ø SA
10/6 SA
RECTANGULAR DUCT
ROUND DUCT
OVAL DUCT
FLEX DUCT
SUPPLY DIFFUSER
RETURN GRILLE
EXHAUST GRILLE
LINEAR SLOT DIFFUSER
EXHAUST DUCT (UP/DOWN/SECTION)
RETURN DUCT (UP/DOWN/SECTION)
SUPPLY DUCT (UP/DOWN/SECTION)
SIDEWALL GRILLE
ROUND DIFFUSER
EXTERIOR LOUVER
VOLUME DAMPER
FIRE DAMPER
SMOKE DAMPER
FIRE/SMOKE DAMPER
M MOTORIZED ACTUATOR
THERMOSTAT
CARBON MONOXIDE SENSOR
HUMIDISTAT
OPPOSED BLADE DAMPER
PARALLEL BLADE DAMPER
T
H
CO
R E
G I S T E R E D P R O F E S S
I O N
A L
E
NG I NE E
R
87183PE
OREGONM
A Y 1 1 , 2 0 2
EXPIRES: JUN. 30, 2026
G U
S
T A V O V E L A M O R
E N
O
Scale
Date
Sheet No.
935 SE Alder Street : Portland Oregon 97214 tel 503 239 1987
312 NW 10th Ave, Suite 100
Portland, OR 97209 503-212-4612
As Noted
M000
GENERAL NOTES &
SYMBOLS
ADMIN BUILDING REMODEL
10/1/2025
WES KELLOGG WRRF
11525 SE MCLOUGHLIN BLVD
MILWAUKIE, OR 97222
PERMIT 10/1/2025
MECHANICAL SHEET LIST
M000 GENERAL NOTES & SYMBOLS
M011 DEMOLITION PLAN - LEVEL 1 - EAST
M012 DEMOLITION PLAN - LEVEL 1 - WEST
M013 DEMOLITION ROOF PLAN
M101 FLOOR PLAN - LEVEL 1 - EAST
M102 FLOOR PLAN - LEVEL 1 - WEST
M103 ROOF PLAN
M401 DETAILS
M501 SCHEDULES
M502 SCHEDULES
M601 CONTROLS
MP102 FLOOR PLAN - LEVEL 1 - WEST MECH PIPING
Issue Revision Date
CONTACT 811 BEFORE YOU DIG:
UNDERGROUND FACILITIES, STRUCTURES, AND UTILITIES HAVE BEEN SHOWN BASED UPON INFORMATION OBTAINED FROM FIELD LOCATIONS BY UTILITY COMPANIES, AVAILABLE SURVEYS AND RECORDS. THEIR LOCATIONS MUST BE CONSIDERED APPROXIMATE ONLY. IT IS ALSO POSSIBLE THAT THERE MAY BE OTHER UNDERGROUND FACILITIES, STRUCTURES, AND UTILITIES IN EXISTENCE THAT ARE NOT SHOWN. IT IS THE RESPONSIBILITY OF EACH INDIVIDUAL PARTY REFERENCING THIS PLAN TO DETERMINE THE EXACT LOCATION AND TYPE OF UNDERGROUND FACILITIES ON THE SITE. HAND EXCAVATE AT CRITICAL POINTS AS NECESSARY TO VERIFY LOCATIONS, SIZES, ELEVATIONS, FLOW LINES, ETC. IF A PROBLEM OR INTERFERENCE EXISTS, NOTIFY ARCHITECT/ENGINEER BEFORE PROCEEDING.
PLUMBING PIPING LEGEND
DCW
DHW
DHWR
SAN
V
G
ST
SO
DOMESTIC COLD WATER
DOMESTIC HOT WATER
DOMESTIC HOT WATER RETURN
SANITARY
VENT
NATURAL GAS
STORM DRAIN
STORM OVERFLOW
PLUMBING ABBREVIATIONS
AD ACCESS DOOR OR AREA DRAIN GAL GALLON
AFF ABOVE FINISHED FLOOR GALV GALVANAIZED
AFG ABOVE FINISHED GRADE GC GENERAL CONTRACTOR
BOP BOTTOM OF PIPE GPH GALLONS PER HOUR
BOT BOTTOM GPM GALLONS PER MINUTE
BV BALL VALVE GW GREASE WASTE
CB CATCH BASIN
HB HOSE BIBB
CI CAST IRON
HR HOUR
CL CENTER LINE
IMB ICE MAKER BOX
CO CLEAN OUT
JR JANITOR RECEPTOR
CONC CONCRETE
L LAVATORY
COND CONDENSATE MB MOP BASIN
CONTR CONTRACTOR MC MECHANICAL CONTRACTOR
CP CIRCULATION PUMP MECH MECHANICAL
CT COW'S TONQUE MH MANHOLE
CWP CIRCULATING WATER PUMP NTS NOT TO SCALE
DN DOWN OD OVERFLOW DRAIN
DR DRAIN PC PLUMBING CONTRACTOR
DS DOWNSPOUT PRV PRESSURE REDUCING VALVE
DWV DRAIN, WASTE & VENT PSI POUNDS PER SQUARE INCH
EC ELECTRICAL CONTRACTOR PVC POLYVINYL CHLORIDE
EEW EMERGENCY EYE WASH RD ROOF DRAIN
ESH EMERGENCY SHOWER RV RELIEF VALVE
EQUIP EQUIPMENT S SINK
ESE EMERGENCY SHOWER/EYEWASH ST STORM
EWC ELECTRIC WATER COOLER SH SHOWER
EWT ENTERING WATER TEMPERATURE SO STORM OVERFLOW
EX EXISTING TCC TEMP. CONTROL CONTRACTOR
EXP EXPANSION TP TRAP PRIMER
FCO FLOOR CLEAN OUT TYP TYPICAL
FD FLOOR DRAIN UR URINAL
FLEX FLEXIBLE
VTR VENT THROUGH ROOFFLR FLOOR DRAIN
WB WALL BOX - CONDENSATEFPM FEET PER MINUTE
WC WATER CLOSETFPS FEET PER SECOND
WCO WALL CLEANOUTFS FLOOR SINK
WH WATER HEATERFSEC FOOD SERVICE EQUIP. CONSULT.
WHA WATER HAMMER ARRESTORFTG FOOTING
WMF WASHING MACHINE FIXTUREGA GAGE
ELEMENT PHASE ABBREVIATIONS
(E) EXISTING ITEM TO REMAIN
(ER) NEW LOCATION OF EXISTING ITEM
(N) NEW ITEM IN EXISTING LOCATION
(R) EXISTING ITEM TO BE REMOVED, PATCH AND/OR COVER
(RN) REPLACE EXISTING ITEM WITH NEW
(RR) EXISTING ITEM TO BE REMOVED AND RELOCATED
VAC VACUUM
CA COMPRESSED AIR
LF LABRATORY FIXTURE
PLUMBING AND PIPING SYMBOLS
SINGLE LINE DOUBLE LINE
90° ELBOW
90° ELBOW - SHORT SWEEP
90° ELBOW - LONG SWEEP
90° ELBOW - OUTLET DOWN
90° ELBOW - OUTLET UP
45° ELBOW
22° ELBOW
TEE
TEE - OUTLET DOWN
TEE - OUTLET UP
WYE
COMBINATION WYE & 1/8 BEND
DOUBLE COMBO
COUPLING
CAP
REDUCER
BALL VALVE
TEE - SANITARY
P-TRAP - PLAN VIEW
P-TRAP - SECTION
REDUCED PRESSURE BACKFLOW PREVENTER
PLUMBING GENERAL NOTES:
1. COORDINATE PLUMBING WORK WITH ALL OTHER TRADES. BEGIN INSTALLATION AND ROUGH-IN AFTER COORDINATION WITH ALL TRADES ASSOCIATED WITH PROJECT SCOPE. COORDINATE PLUMBING SYSTEMS INSTALLATION WITH BUILDING STRUCTURE, ARCHITECTURAL ASSEMBLIES, SHEET METAL, DUCTWORK, LIGHTING FIXTURES, CONDUITS, CABLE TRAYS, ETC. REFER TO ALL GENERAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT. CONTRACTOR IS RESPONSIBLE FOR REWORK ASSOCIATED WITH FAILURE TO
COORDINATE.
2. PROVIDE A COMPLETE PLUMBING SYSTEM INCLUDING PIPE, INSULATION, HANGERS, SUPPORTS, EQUIPMENT, WATER HEATERS, FIXTURES, MIXING VALVES, VALVES, ACCESSORIES AND SPECIALTIES. INSTALL ALL EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. SIZING AND INSTALLATION OF PLUMBING SYSTEMS TO COMPLY WITH ALL
STATE AND LOCAL CODES AND PROJECT REQUIRMENTS.
3. DRAWING PLANS, SCHEMATICS AND DIAGRAMS INDICATE GENERAL LOCATION AND ARRANGEMENT OF PLUMBING
SYSTEM.
4. INCORPORATE PLUMBING DRAWINGS, SPECIFICATIONS, STATE AND LOCAL CODES, AND PROJECT STANDARDS INTO
WORK.
5. EXISTING PLUMBING PIPING AND EQUIPMENT SHOWN ARE BASED ON NON-DESTRUCTIVE SITE OBSERVATION AND AS-BUILT DOCUMENTS PROVIDED BY THE OWNER. FIELD VERIFY ALL EXISTING CONDITIONS INCLUDING LOCATION
OF ALL PIPING CONCEALED IN BUILDING ASSEMBLIES WHERE WORK IS REQUIRED.
6. CONTRACTOR IS RESPONSIBLE FOR MAKING PENETRATIONS WHERE REQUIRED IN EXISTING WALLS, FLOORS, CEILINGS AND ROOFS. MAKE PENETRATIONS NEAT. PATCH, CONCEAL OR CAULK ALL OVERCUT TO PREVENT NOISE TRANSFER BETWEEN SPACES. COVER EXPOSED WALL PENETRATIONS WITH ESCUTCHEONS OR SHEET METAL AS
APPROPRIATE.
7. REFER TO ARCHITECTURAL SPECIFICATIONS FOR THROUGH-PENETRATION FIRESTOPPING AND TO ARCHITECTURAL CODE PLAN FOR FIRE RATED WALLS, FLOORS AND CEILINGS. CONTRACTOR IS RESPONSIBLE TO FIRESTOP PENETRATIONS THROUGH RATED ASSEMBLIES. PROVIDE FIRE CAULKING FOR PENETRATIONS OF FIRE RATED
ASSEMBLIES.
8. CONTINUE PIPE INSULATION UNBROKEN THROUGH WALL, FLOOR AND CEILING PENETRATIONS. SEAL AROUND PIPE
INSULATION AT PENETRATIONS.
9. CREATE OPENINGS IN BUILDING AS REQUIRED TO REMOVE EXISTING BUILDING COMPONENTS AND BRING IN NEW EQUIPMENT. PATCH ALL OPENINGS CREATED. PATCH FINISH TO MATCH EXISTING CONDITIONS. INCLUDE THIS
WORK IN BID.
10. VERIFY WITH ENGINEER ANY FIXTURES NOT TAGGED OR PIPED PRIOR TO ANY WORK. UNLESS SPECIFICALLY NOTED AS EXCLUDED FROM SCOPE CONTRACTOR IS RESPONSIBLE FOR ALL PLUMBING FIXTURES SHOWN ON
ARCHITECTURAL DRAWINGS; TAGGED OR NOT TAGGED ON PLUMBING DRAWINGS.
XXX
GENERAL SYMBOLS
EQUIPMENT IDENTIFICATION
KEYNOTE
POINT OF DISCONNECT
NEW POINT OF CONNECTION
DEMOLITION LINEWORK TO BE SHOWN AS BOLD DASHED AND BLACK
NEW LINEWORK TO BE SHOWN AS BOLD AND BLACK
EXISTING LINEWORK TO BE SHOWN AS "HALFTONE"
HIDDEN LINEWORK TO BE SHOWN AS THIN DASHED AND BLACK
PLUMBING DEMOLITION NOTES:
1. PLUMBING DEMOLITION DRAWINGS SHOWING EXISTING CONDITIONS HAVE BEEN PREPARED BASED ON NON- DESTRUCTIVE SITE OBSERVATIONS AND AS-BUILT DOCUMENTS PROVIDED BY THE OWNER. CONTRACTOR TO FIELD VERIFY EXISTING SYSTEMS PRIOR TO BEGINNING WORK. NOTIFY ARCHITECT/ENGINEER IF EXISTING CONDITIONS
ARE MATERIALLY DIFFERENT THAN THOSE SHOWN ON THE DRAWINGS.
2. BE FAMILIAR WITH EXISTING PLUMBING SYSTEMS THAT WILL BE AFFECTED BY THE DEMOLITION WORK. OBTAIN PERMISSION FROM THE OWNER'S REPRESENTATIVE TO SHUT OFF SERVICES OR SYSTEMS THAT AFFECT AREAS BEYOND THE LIMITS OF THE IMMEDIATE DEMOLITION AREA. INFORM THE OWNER'S REPRESENTATIVE OF THE REASON FOR AND DURATION OF THE SHUTDOWN. MINIMIZE IMPACT TO OTHER AREAS. PROCEED WITH THE
SHUTDOWN AFTER PERMISSION FROM THE OWNER IS GRANTED.
3. REMOVE PIPING, HANGERS, FIXTURES, EQUIPMENT, APPURTENANCES, ETC. THAT ARE INDICATED TO BE REMOVED.
PERFORM WORK IN A TIMELY MANNER AND IN ACCORDANCE WITH THE GENERAL DEMOLITION SPECIFICATIONS.
COORDINATE WITH THE OWNER AND OTHER CONTRACTORS.
4. UNLESS NOTED AS OWNER'S SALVAGE, DISPOSE OF REMOVED EQUIPMENT AND MATERIALS PROMPTLY.
5. REMOVE ALL ABANDONED PIPING, HANGERS, FIXTURES, EQUIPMENT AND APPURTENANCES THAT ARE EXPOSED OR ACCESSIBLE WITHOUT WALL OR CEILING DEMOLITION. REFER TO ARCHITECTURAL PLANS FOR CEILINGS TO BE
REMOVED.
R E
G I S T E R E D P R O F E S S
I O N
A L
E
NG I NE E
R
87183PE
OREGONM
A Y 1 1 , 2 0 2
EXPIRES: JUN. 30, 2026
G U
S
T A V O V E L A M O R
E N
O
Scale
Date
Sheet No.
935 SE Alder Street : Portland Oregon 97214 tel 503 239 1987
312 NW 10th Ave, Suite 100
Portland, OR 97209 503-212-4612
As Noted
P000
GENERAL NOTES &
SYMBOLS
ADMIN BUILDING REMODEL
10/1/2025
WES KELLOGG WRRF
11525 SE MCLOUGHLIN BLVD
MILWAUKIE, OR 97222
PERMIT 10/1/2025
PLUMBING SHEET LIST
P000 GENERAL NOTES & SYMBOLS
P001 DEMOLITION PLAN - FOUNDATION - EAST
P002 DEMOLITION PLAN - FOUNDATION - WEST
P011 DEMOLITION PLAN - LEVEL 1 - EAST
P012 DEMOLITION PLAN - LEVEL 1 - WEST
P013 DEMOLITION ROOF PLAN
P101 FLOOR PLAN - FOUNDATION - EAST
P102 FLOOR PLAN - FOUNDATION - WEST
P111 FLOOR PLAN - LEVEL 1 - EAST
P112 FLOOR PLAN - LEVEL 1 - WEST
P121 ROOF PLAN
P401 DETAILS
P402 DETAILS
P501 SCHEDULES
P502 SCHEDULES
Issue Revision Date