BID 2025-83 Clarifying Questions-2.pdf

PDF 10 MB Posted

Attached to
BID #2025-83 Kellogg Creek WRRF Administration Building Remodel
Solicitation number
S-C01010-00015482
Issued by
Clackamas County, Oregon

About this file

Clarifying Questions and Submittal Review for BID #2025-83 Kellogg Creek WRRF Administration Building Remodel

This document comprises clarifying questions and responses, along with a lighting submittal review, for Bid #2025-83 issued by Clackamas County Water Environment Services for the Kellogg Creek Water Resource Recovery Facility Administration Building Remodel project. The file addresses technical specifications and product substitutions related to the project's lighting systems and related building components. Key clarifications address storefront door specifications (replacing incorrect "360 Insulclad" reference with Kawneer Insulpour 500T), storefront system glazing (replacing with Kawneer Trifab 451T), frame type schedules (to be clarified in Addendum 3), door schedule revisions for D4 door type 115A, removal of extended warranty requirements for spontaneous glass breakage (paragraph 08 80 00-1.12, 3 to be deleted in Addendum 3), and a frame type schedule note to be added to sheets A501 and A502. The non-mandatory pre-bid conference was scheduled for December 16, 2025, at 11:00 AM, with sealed bids due January 8, 2026 (later extended to January 15, 2026 per the contract opportunity summary), at 2:00 PM Pacific Time. Substantial completion is required within 274 calendar days, with final completion within 304 calendar days.

The lighting submittal review, completed December 29, 2025, by Austin Tanzer on behalf of Deca Architecture, evaluated a comprehensive lighting package submitted by Solus Lighting & Controls. The review approved most fixture substitutions with notes (including A1E with 90-minute battery confirmation, D2 with waterproof verification, and F2 with power supply confirmation), but rejected six lighting substitutions: L2, L4, L5, P1, P2, and S1, citing architectural rejection or mismatched finish and quality specifications. The contractor is responsible for confirming all fixture options with manufacturers and coordinating with other trades. Submittal documentation includes detailed specifications for LED troffers (2'×2' and 2'×4' sizes), downlights (6-inch and 8-inch apertures), emergency lighting, strip lighting, linear fixtures, and task lighting, all with varying lumen outputs, correlated color temperatures, dimming capabilities, and control options. These products must comply with design specifications and coordinate with the building's mixed B and A-3 occupancy requirements and seismic design standards.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INVITATION TO BID #2025-83

Kellogg Creek WRRF Administration Building Remodel (“BID”)

RESPONSE TO CLARIFYING QUESTIONS

January 12, 2026

Note that these are questions submitted by interested firms to the above referenced solicitation.

The below answers are for clarification purposes only and in no way alter or amend the BID as published.

1. Storefront doors specified 360 Insulclad are not available in the U.S. market per

Kawneer, can the design team provide an alternate?

Answer: The “360 Insulclad” doors noted in paragraph 08 40 00-2.6, C is incorrect.

Replace with Kawneer Insulpour 500T.

2. Storefront system only indicates center glazed, is there a certain product you want to use?

Answer: The “Insulpour 500T” system noted in paragraph 08 40 00-2.5, C, 1 is incorrect. Replace with Kawneer Trifab 451T.

3. Is there a HSF frame type schedule?

Answer: A frame type schedule is not included with the document set, however a note clarifying sidelite dimensions will be added to sheets A501 & A502 with

Addendum 3.

4. There appears to be some D4 type of doors on the interior elevations but none indicated on the doors schedule, can the door schedule be revised to show these?

Answer: There is one type D4 door, 115A. The door schedule will be revised to correct the door type for 115A.

5. Please confirm specification requirement 088000-1.12-3 extended warranties for spontaneous glass breakage – this requires tempered glazing to be heat soaked and warranty may still not be available from the manufacturer.

Answer: No extended warranty for spontaneous breakage is required. Paragraph 08

80 00-1.12, 3 will be removed with Addendum 3.

6. Substitution requests:

a. 10 65 00 Operable partition – not accepted

b. 26 00 00 Lighting – reviewed with comments

End of Clarifying Questions #2

SUBMITTAL REVIEW

Section No: Lighting Reviewed By: Austin Tanzer

Section Name: - Date Reviewed: 1/8/2026

General Comments:

This review is only for general conformance with the design concept of the project and general compliance with the information given in the Contract Documents. Corrections or comments made on the submittals during this review do not relieve the contractor from compliance with the requirements of the plans and specifications. Approval of a specific item shall not include approval of assembly of which the item is a component. Contractor is responsible for: dimensions to be confirmed and correlated at the jobsite; information that pertains solely to the fabrication processes or to the means, methods, techniques, sequences, and procedures of construction; coordination of their work with that of all other trades;

and for performing all work in a safe and satisfactory manner.

☐Reviewed ☒Reviewed with Comments ☐Revise and Resubmit ☐Rejected

Item Description Review Status Comments

General Comment Fixtures not noted are approved with no exceptions.

Contractor to confirm all options specified on basis of design fixtures shall be made available. All fixture options specified on BOD shall be provided with the substitutions. Finishes shall be as specified or as otherwise directed by the Architect.

A1E Substitution approved with notes.

Confirm selected battery will last 90 minutes with manufacturer.

D2 Substitution approved with notes.

Confirm selection is water tight with manufacturer.

F2 Substitution approved with notes.

Confirm power supply and any additional accessory requirements with manufacturer.

L2 Substitution Rejected Rejected by arch.

L4 Substitution Rejected Rejected by arch.

L5 Substitution Rejected Rejected by arch.

P1 Substitution Rejected Rejected by arch.

P2 Substitution Rejected Rejected by arch.

S1 Substitution Rejected Finish and quality not matching BOD.

Date: Dec 29, 2025

Solus Lighting & Controls 1820 E Burnside St Portland OR 97214 Phone: (503) 768-9999

Job Name Kellogg Creek WRRF Admin Bldg Remodel

SOLUS25-224731

Milwaukie OR

Bid Date Jan 15, 2026

Submittal Date Dec 22, 2025

Architect:

Deca Architecture

935 SE Alder Street Portland OR 97214

Engineer:

KCL Engineering - Portland 312 NW 10th Ave Suite 100

Portland OR 97209

Date: Dec 29, 2025 Page 1/2

Transmittal Solus Lighting & Controls 1820 E Burnside St Portland OR 97214 Phone: (503) 768-9999 From: Rochelle Montgomery

FF00009 Page 1/2www.solus.com

Project Kellogg Creek WRRF Admin Bldg Remodel Quote# SOLUS25-224731 Location Milwaukie OR

Contact:

ATTACHED WE ARE SENDING YOU 1 COPY OF THE FOLLOWING ITEM:

Drawings Specifications Other:

Prints Information Plans Submittals

THESE ARE TRANSMITTED FOR:

X Prior Approval Resubmittal for Approval Record

Approval Corrections Bids due on:

Approval as Submitted Your Use Other:

Approval as Noted Review and Comment

Type MFG Part

MISC SUBSTITUTION REQUEST FORM

A1 Metalux 22CZ2-20-UNV-L835-CD1-U

MISC SUBSTITUTION REQUEST FORM

A1E Metalux 22CZ2-20-UNV-XX-L835-CD1-U

MISC SUBSTITUTION REQUEST FORM

A2 Metalux 24CZ2-30-UNV-L835-CD1-U

MISC SUBSTITUTION REQUEST FORM

D1 Halo HC605D010-HM50525835-61XH

MISC SUBSTITUTION REQUEST FORM

D2 Halo HC820D010-HM80520835-81PSXXW

MISC SUBSTITUTION REQUEST FORM

E1 Sure-Lites APELH2BK

MISC SUBSTITUTION REQUEST FORM

F1 Metalux 4SLSTPSLC-UNV

MISC SUBSTITUTION REQUEST FORM

F2 Jesco Lighting Group Llc S700-XX-3590

MISC SUBSTITUTION REQUEST FORM

L1 Pinnacle Arch. Lighting Inc. EX2D-A-N-XX-5-S-1-FSD-1-0-S

MISC SUBSTITUTION REQUEST FORM

L2 Scott Architectural Lighting S3A41-L16-35K-XX

MISC SUBSTITUTION REQUEST FORM

L3 Pinnacle Arch. Lighting Inc. EV3-WET-835-2-IND-FL-U-FSD-1-0-BL

MISC SUBSTITUTION REQUEST FORM

L4-3' Prudential Lighting MIC-PRO-LED35-SO-3'-SC-UNV-DM01

MISC SUBSTITUTION REQUEST FORM

L5-6' Prudential Lighting MIC-PRO-LED35-SO-6'-SC-UNV-DM01

MISC SUBSTITUTION REQUEST FORM

P1-8' Pinnacle Arch. Lighting Inc. EX2DI-XX-BW-XX-35-8-XX-U-FSD-1-0-S

MISC SUBSTITUTION REQUEST FORM

P2-4' Pinnacle Arch. Lighting Inc. EX2DI-XX-BW-XX-35-4-XX-U-FSD-1-0-S

MISC SUBSTITUTION REQUEST FORM

P3 Halo HCC4S15D010MW-HM40525835-

41XXH

Date: Dec 29, 2025 Page 2/2

Transmittal Solus Lighting & Controls 1820 E Burnside St Portland OR 97214 Phone: (503) 768-9999 From: Rochelle Montgomery

FF00009 Page 2/2www.solus.com

Type MFG Part

MISC SUBSTITUTION REQUEST FORM

S1 McGraw-Edison GKO-PB1C-830-U-T3-XX

MISC SUBSTITUTION REQUEST FORM

S2 Pinnacle Arch. Lighting Inc. EX3-WET-N-CL835750-8-IND-WA-U-

FSD-1-0-BL

MISC SUBSTITUTION REQUEST FORM

W1 Halo VT0840L

MISC SUBSTITUTION REQUEST FORM

X1 Sure-Lites APX7RG

MISC SUBSTITUTION REQUEST FORM

X2 Sure-Lites APX7RG

MISC SUBSTITUTION REQUEST FORM

X3 Sure-Lites APX7RG

SUBSTITUTION

CSI Form 1.5C REQUEST

(During the Bid Period)

Substitution Request Number: Project:

From:

Date: To:

A/E Project Number:

Contract For: Re:

© Copyright 2007, Construction Specifications Institute, 110 South Union Street, Suite 100, Alexandria, VA 22314

Page 1 Form Version: June 2004 CSI Form 1.5C

This is not an official CSI Construction Contract Administration (CCA) Form. Please use CSI's official CCA Forms if required by your project needs.

Specification Title: Description:

Section: Page: Article/Paragraph:

Proposed Substitution:

Manufacturer: Address: Phone:

Trade Name: Model No.:

Attached data includes product description, specifications, drawings, photographs, and performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified.

Attached data also includes a description of changes to the Contract Documents that the proposed substitution will require for its proper installation.

The Undersigned certifies:

• Proposed substitution has been fully investigated and determined to be equal or superior in all respects to specified product.

• Same warranty will be furnished for proposed substitution as for specified product.

• Same maintenance service and source of replacement parts, as applicable, is available.

• Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule.

• Proposed substitution does not affect dimensions and functional clearances.

• Payment will be made for changes to building design, including A/E design, detailing, and construction costs caused by the substitution.

Submitted by:

Signed by:

Firm:

Address:

Telephone:

A/E’s REVIEW AND ACTION

Substitution approved - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures.

Substitution approved as noted - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures.

Substitution rejected - Use specified materials.

Substitution Request received too late - Use specified materials.

Signed by: Date:

Supporting Data Attached: Drawings Product Data Samples Tests Reports

Kellogg Creek WRRF Administrative Building Remodel 1

Deca Architecture Inc 12/22/2025

KCL Engineering

Lighting Substitution

Lighiting

All

Rochelle Montgomery

Rochelle Montgomery

26 00 00

Lighting All

Solus Lighting & Controls

1820 E Burnside St

Portland, OR 97214

503-768-9999

Submitted by Solus Lighting & Controls

Job Name:

Kellogg Creek WRRF Admin Bldg Remodel Architect: Deca Architecture (Portland) Engineer: KCL Engineering - Portland (Portland)

Catalog Number:

SUBSTITUTION REQUEST FORM

Notes:

Type:

MISC

SOLUS25-224731

Index Page1/1Submitted On: Dec 22, 2025

PS519305EN page 1 December 9, 2025 3:01 PM

Project Catalog # Type

Prepared by Notes Date

Top Product Features

•Latch-less design provides clean architectural look
•BioUp melanopic lighting options for 30% circadian boost and earn WELL Building Standard points
•VividTune CCT tuning options from 3000K-5000K or 2700K-6500K
•Designers delight - ribbed, smooth and round perforated lens options
•High performance efficacy up to 151 lm/W
•Integrated sensor systems - occupancy, daylight and IoT connectivity
•Options to meet Build America, Buy America, Buy American and other domestic preference requirements

Dimensional and Mounting Details

Cruze ST 22CZ2

2' x 2' LED Specification Grade Troffer

Typical Applications

Office • Education • Healthcare • Hospitality • Retail

Ceiling Trim Type Type Exposed Grid Standard Concealed T Standard Slot Grid Standard Flange *

G Grid/Lay-in Standard

G Concealed T

G Slot Grid

*See Drywall Frame Kit Accessory in Ordering Information Section

Ceiling Compatibility

Interactive Menu

• Order Information page 2

• Photometric Data page 3

• Control Solutions page 5

• VividTuneTM Color Tuning Solutions page 6

• BioUp - Melanopic Lighting page 7

• Product Warranty

3-1/4" [83mm]

23-3/4" [603mm]

7" [179mm]

23-3/4" [603mm]

15-3/4" [401mm] 23-3/4" [603mm]

5-1/2" [142mm]

Shielding

HRP - High-Efficiency Round Perf Inlay

See ordering information for more shielding options.

SQR - Square Ribbed Frosted Acrylic Lens

AVAIL ABL E

CO

MPLIANT OPTIONS

BABA

BUILD AMERICA

BUY AMERICA

Product Certification

Product Features

Designed to provide safe and convenient means of disconnecting power

LITE

WaveLinx

PRO

WaveLinx BioUp

Melanopic Lighting

Submitted by Solus Lighting & Controls

Job Name:

Kellogg Creek WRRF Admin Bldg Remodel Architect: Deca Architecture (Portland) Engineer: KCL Engineering - Portland (Portland)

Catalog Number:

22CZ2-20-UNV-L835-CD1-U

Notes:

Type:

A1

Index Page1/8Submitted On: Dec 22, 2025

22CZ2 LED

PS519305EN page 2 December 9, 2025 3:01 PM

Order Information

SAMPLE ORDER NUMBER: 22CZ2-34HE-UNV-L835-CD1-U

Domestic Preferences (1) Rating Series Air Lumen Level / Efficacy Option

[Blank]=Standard BAA=Buy American Act TAA=Trade Agreements Act BABA=Build America Buy America Act

[Blank]=Standard

ATW-SW4=

Chicago Rated

22CZ2=2x2 Cruze ST

[Blank]=Standard A=Air (Vented) (2)

Standard [Blank] 20=2000 Lumens (4)

24=2400 Lumens (4)

32=3200 Lumens (3)

39=3900 Lumens (3)

44=4400 Lumens (3)

High Efficacy [HE] (4), (5)

20HE=2000 Lumens 24HE=2400 Lumens 29HE=2900 Lumens 34HE=3400 Lumens 39HE=3900 Lumens 44HE=4400 Lumens

Very High Efficacy [VHE] 20VHE=2000 Lumens 24VHE=2400 Lumens 29VHE=2900 Lumens 34VHE=3400 Lumens 39VHE=3900 Lumens 44VHE=4400 Lumens 50VHE=5000 Lumens 55VHE=5500 Lumens

60VHE=6000 Lumens (5)

65VHE=6500 Lumens (5)

70VHE=7000 Lumens (3), (6)

75VHE=7500 Lumens (3), (6)

80VHE=8000 Lumens (3), (6)

85VHE=8500 Lumens (3), (6)

90VHE=9000 Lumens (3), (6)

95VHE=9500 Lumens (3), (6)

100VHE=10000 Lumens (3), (6)

110VHE=11000 Lumens (3), (6)

Notes Notes Notes

(1) Only product configurations with these prefixes are built to be compliant with the Buy American Act of 1933 (BAA), Trade Agreements Act of 1979 (TAA), or the Build America Buy America Act (BABA). BABA is the minimum Government compliance requirement for the Build America Buy America standards which is part of the Infrastructure and Investment Jobs Act (IIJA). Individual Government Agencies may have more stringent compliance standards. Please refer to DOMESTIC PREFERENCES website or consult the CLS Domestic Preferences team for more information. Components shipped separately may be separately analyzed under domestic preference requirements.

(2) Air version is intended for air return through plenum. See air return data table for air flow volumes.Air option not available with ATW-SW4. Air requires “PAF” option.

(3) VividTune white tuning and BioUp static and dynamic options are not available with these lumen/efficacy selections. (4) BioUp lumen option. (5) Vividtune lumen option. (6) Available with CD and HCD drivers only.

Shielding Voltage (5) Options Emergency Options

[Blank]=Ribbed Frosted Acrylic Lens (standard) S=Smooth Frosted Acrylic Lens HRP=High-Efficiency Round Perf Inlay SQR=Square Ribbed Frosted Acrylic Lens

UNV=Universal Voltage 120-277 347V=347 Volt

GL=Single Element Fuse GM=Double Element Fuse PAF=Painted After Fabrication

[Blank]=No emergency EL7W=7-watt 120V-277V emergency battery pack (6)

EL10W=10-watt 120V-277V emergency battery pack (6)

EL14W=14-watt 120V-277V emergency battery pack (6)

EL10WSD=10W emergency battery pack with self-diagnostic installed (6), (8)

EL14WSD=14W emergency battery pack with self-diagnostic installed (6), (8)

ETRD=Emergency Transfer Relay with dimming control (7)

RRU=LVS Controls Emergency Transfer Relay with dimming control (7)

UEL7W=UL924 Listed luminaire, 7-watt, 120V-277V emergency battery pack (6), (10)

UEL14W=UL924 Listed luminaire, 14-watt 120V-277V emergency battery pack (6), (10)

UEL10WSD=Bodine 10W emergency battery pack with self diagnostic installed (6), (9), (10)

UETRD=UL924 Listed luminaire, Emergency Transfer Relay with dimming control (7), (10)

URRU=UL924 Listed luminaire, LVS Controls Emergency Transfer Relay with dimming control (7), (10)

WNPS=WaveLinx wireless Normal Power Sensing (NPS) capable device (23)

Notes Notes

(5) Products also available in non-US voltages and frequencies for international markets.

(6) Factory installed with integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available. Battery option increases total height by 1 inch. (7) Used to bypass local control during outage. Must be used in conjunction with UL 1008 device (provided by others). Devices are universal voltage (UNV). 347 not available. (8) EL10WSD and EL14WSD not available with 347V. (9) UEL10WSD not available with 347V. (10) Cannot be used with BioUP options. (23) Must be ordered with WLS or WPS sensor. WNPS cannot be ordered with emergency or relay options such as ETRD, GTR2, ELxxx or GTDU.

CRI/CCT Flex

L830=80CRI, 3000K

L835=80CRI, 3500K

L840=80CRI, 4000K

L850=80CRI, 5000K

L930=90CRI, 3000K

L935=90CRI, 3500K

L940=90CRI, 4000K

L950=90CRI, 5000K

L83050=80CRI 3000K-5000K White Tuning (12)

L93050=90CRI 3000K-5000K White Tuning (12)

L82765=80CRI 2700K-6500K White Tuning (12)

L92765=90CRI 2700K-6500K White Tuning (12)

B35=BioUp Static 3500K (13)

B40=BioUp Static 4000K (13)

B50=BioUp Static 5000K (13)

B2750=BioUp Tunable 2700K-5000K (14)

[Blank]=No Flex A3/8-4/18GDIM=3/8" Flex with 0-10V Dimming Leads A3/8-2/18G=3/8" Flex with line and common A3/8-5/18GDIM=Flex with 0-10V Dimming leads and Blue for alternate wiring. See below for details.

Notes

(12) VividTune provides correlated color temperatures (CCT) between 3000K (warm) to 5000K (cool) or 2700K (warm) to 6500K (cool). Must be used in conjunction with W2A driver only. Must be used with two (2) 10V dimming control channels, 1 cct, 1 intensity. May be combined with Wavelinx sensor control systems. (13) BioUp Static to be used with HCD driver. (14) BioUp Tunable provides correlated color temperatures (CCT) between 2700K (warm) to 5000K (cool). Must be used with W2A (for two channel 0-10V Control) or W2D (for 2 channel Dali Control) driver. See BioUp page for more information.

Flexible Metal Conduit Options

Flex options available for 0-10V dimming control, DALI dimming control, emergency and night light functions. 72-inch factory-installed and pre-wired to driver, fitted to luminaire housing access plate with 90° enclosed FMC connector. Not all options may be combined and installation ratings vary by type.

See online configurator for all flex options.

A3/8-4/18GDIM series notes: Factory installed dimming option 3/8” flexible metal conduit with 2-#18 power and ground wires and 2-#18 UL-listed jacketed 0-10V +/- control wires. Meets UL 66, 83, 1479, 1569, 1581, 2556. NEC® 250.118, 300.22(C), 392, 396, 330, 501, 502, 503, 530, 504, 505, 518, 520, 530, 645, 72; Federal Specification A-A-59544 (formerly J-C-30B); all applicable OSHA and HUD Requirements. UL Classified 1-, 2-, and 3-hour through penetration with applicable fire stop product (not included). May be surface mounted, fished and/or embedded in plaster. Cable tray and approved raceway rated, install per NEC®; Environmental Air-Handling Space Installation per NEC® 300.22(C).

continued next page

Submitted by Solus Lighting & Controls

Job Name:

Kellogg Creek WRRF Admin Bldg Remodel Architect: Deca Architecture (Portland) Engineer: KCL Engineering - Portland (Portland)

Catalog Number:

22CZ2-20-UNV-L835-CD1-U

Notes:

Type:

A1

Index Page2/8Submitted On: Dec 22, 2025

PS519305EN page 3 December 9, 2025 3:01 PM

Driver Type No. of Drivers Integrated Sensing Systems (17) Packaging Accessories (order separately) (21)

CD=0-10V Driver (10%-100% Dimming) (22)

CDW=NonProgrammable Driver, Limited Lumen Packages, 0-10V Dimming (10%-100%) HCD=0-10V Driver (1%-100% Dimming) (22)

5LTD=DALI Driver (5%-100% Dimming) 5LTHD=DALI Driver (1%-100% Dimming) SD=Step Dimming Driver (50%-100% Dimming) LH=Lutron HiLume 1% EcoSystems (LDE1) (F)

W2A=White Tuning, 2 ch, Analog 0-10V (1%-100% Dimming) (15), (22)

W2D=White Tuning, DALI Type 8 (1%-100% Dimming) (16)

1=1 Driver [Blank]=No Sensor WLS (formerly WAB)=WaveLinx LITE Wireless Sensor, Occupancy w/ photocell, Independent & Networked (19), (B)

WPS (formerly WAA)=WaveLinx PRO Wireless Sensor, Occupancy w/ photocell, Networked (18), (A)

WLN=WaveLinx LITE Wireless Control Node, without sensor (19), (B)

WPN=WaveLinx PRO Wireless Control Node, without sensor (18), (A)

U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton

CZ2-EQCLIP-U PK=“CZ2” Earthquake Clip Kit (4 clips per bag kit) (20) DF-22W-U=2' x 2' Drywall Frame Kit SMK-22-W=4" Tall Surface Mount Kit, 2' x 2'

Notes Notes Notes

(15) W2A used with two (2) 10V dimming control channels - CCT and intensity. (16) W2D for use with BioUp options only. White tuning CCT between 2700K and 5000K. Must be used with DALI controls; one address to control two channels - intensity and CCT. May not be used with sensing systems. For Emergency options ONLY EL10WSD can be used.

(22) When selecting 0-10V driver with Integrated Sensing System a 0-10V driver might be susbstituted with another type.

Integrated options must be used in conjunction with the associated system and may not be compatible with other options or accessories. Please refer to the following: (F) Consult Marketplace Options - Lutron system pages for additional details and compatibility.

Compatible only with driver series shown, and may require two or more drivers. Requires field commissioning to operate or dim. Contact Lutron at www.lutron.com.

(17) Matching width lens band on other side of sensor band may be supplied for symmetrical appearance. Required for use with sensor and emergency combination. Add “D” to sensor ordering as shown - WPSD, WLSD. (18) WPS sensor and WPN node to be used with CD, HCD or W2A driver. (19) WLS sensor and WLN node to be used with CD or HCD driver.

Integrated options must be used in conjunction with the associated system and may not be compatible with other options or accessories. Please refer to the following: (A) Consult WaveLinx PRO system pages for additional details and compatibility. (B) Consult WaveLinx LITE system pages for additional details and compatibility.

(20) An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture.

(21) Accessories sold separately will be separately analyzed under domestic preference requirements. Consult factory for further information.

Order Information

CONTINUED

Submitted by Solus Lighting & Controls

Job Name:

Kellogg Creek WRRF Admin Bldg Remodel Architect: Deca Architecture (Portland) Engineer: KCL Engineering - Portland (Portland)

Catalog Number:

22CZ2-20-UNV-L835-CD1-U

Notes:

Type:

A1

Index Page3/8Submitted On: Dec 22, 2025

PS519305EN page 4 December 9, 2025 3:01 PM

Photometric Data

22CZ2-24-UNV-L830-CD1-U

Dimming Driver Linear LED 3000K Spacing criterion: (II) 1.2 x mounting height, (⊥)

1.28 x mounting height Lumens: 2437 Input Watts: 21.9W Efficacy: 111.3 LPW Test Report: 22CZ2-24-UNVL830-CD1-U.IES

22CZ2-24HE-UNV-L830-CD1-U

Dimming Driver Linear LED 3000K Spacing criterion: (II) 1.19 x mounting height, (⊥)

1.27 x mounting height Lumens: 2402 Input Watts: 19.2W Efficacy: 125.1 LPW Test Report: 14CZ2-29-UNV-L830-CD1-U.IES

0˚ 30˚

40˚

50˚

70˚

90˚

20˚

80˚

60˚

10˚

0˚ 30˚

40˚

50˚

70˚

90˚

20˚

80˚

60˚

10˚

Product Specifications Construction

• Die formed of code gauge prime cold rolled steel with full length die-formed stiffeners

• Unibody endplates attached with interlocking tabs and screws

•Hemmed side flanges
•Four auxiliary fixture end suspension points
•Integral Grid-lock feature for endplates for added

safety

• Optional earthquake clips available

Integrated Controls

• Standard with 0-10V dimming driver (10% standard, 1% optional)

• Integrated WaveLinx options provide wireless individual fixture control and enable code compliance, increased energy savings, grouping of fixtures, and connection to WaveLinx control systems

• DALI 2.0, Lutron, and step-dimming available

LED and Light Engine

• LED’s available in 3000K, 3500K, 4000K, or 5000K at

80 CRI minimum and 90 CRI minimum

•Color accuracy ≤3-Step MacAdam ellipse (SDCM)
•TM21 life at 60,000 hours up to L90 and calculated

L70 exceeds 203,000 hrs.

•Drivers available in 120-277V and 347V
•Tunable white options available with Cooper

Lighting Solutions’ VividTune

• BioUp melanopic lighting options available in static or tunable white

Emergency Options

• 120V-277V integral emergency battery pack comes in 7-watts, 10-watt, or 14-watts

• Self-diagnostic emergency battery available in 10 or

14-watts (NFPA 101® Life Safety Code®)

• Constant power to the LED system for controlled, predictable discharge

• Integrated test switch/indicator light visible from floor

•Min. 90-minute backup period for code compliance
•Integral emergency transfer relay available for

generator equipped power systems

• WNPS enables Normal Power Sensing (NPS) functionality, allowing detection of normal power availability as part of a WaveLinx EM solution

• NPS must be ordered with Wavelinx LITE or PRO sensor to enable wireless sensing EM solution

• Order standard product with compatible emergency control device (ESP-P) when pairing NPS enabled luminaires in any space

• NPS luminaires meet requirements

Shielding

•Ribbed acrylic frosted lens standard
•Optional smooth acrylic frosted lens (S)
•Optional square ribbed frosted acrylic lens (SQR)
•Optional High-Efficiency Round Perf Inlay (HRP)
•Replacement lenses available, contact factory
•Lens is acrylic with features on the face and

sides to optimize the direct and indirect lighting contributions for improved glare and efficacy

Compliance

•IC rated for insulation contact
•cULus listed for damp locations
•RoHS compliant
•Tested to IESNA LM-79 and LM-80
•Stated life tested to TM21 standards
•Can be used for State of California Title 24 high

efficacy luminaire

BABA Domestic Preference Compliance

• This Cooper product is manufactured in the US and meets the BABA cost of components rule. To verify a configured product with specific accessories and options meets BABA Domestic Preference Requirements; submit this catalog number to Cooper Lighting Quotation team for validation by our Engineering and Manufacturing teams. Our BABA designation is based on the minimum compliance requirement for BABA. Individual Government Agencies may have more stringent compliance standards. Please refer to the DOMESTIC PREFERENCES website or consult the CLS Domestic Preferences team for more information.

Components shipped separately may be separately analyzed under domestic preference requirements.

Warranty

• Five-year limited warranty standard. Optional ten year limited warranty available.

Finish

•Multistage, iron phosphate pretreatment
•90% reflective, matte white enamel finish
•Full fixture housing pre-painted matte white (choose

PAF option for “Paint after Fabrication”)

View IES files

Submitted by Solus Lighting & Controls

Job Name:

Kellogg Creek WRRF Admin Bldg Remodel Architect: Deca Architecture (Portland) Engineer: KCL Engineering - Portland (Portland)

Catalog Number:

22CZ2-20-UNV-L835-CD1-U

Notes:

Type:

A1

Index Page4/8Submitted On: Dec 22, 2025

PS519305EN page 5 December 9, 2025 3:01 PM

High Efficacy Versions – Two Rows of LEDs

Catalog Number Lumens Watts lm/W

22CZ2-20HE-UNV-L835-CD1-U 2030 15.0 135

22CZ2-24HE-UNV-L835-CD1-U 2474 18.1 137

22CZ2-29HE-UNV-L835-CD1-U 2982 20.9 143

22CZ2-34HE-UNV-L835-CD1-U 3426 24.3 141

22CZ2-39HE-UNV-L835-CD1-U 3997 28.5 140

22CZ2-44HE-UNV-L835-CD1-U 4567 32.8 139

Energy and Performance Data

Lumen Maintenance

Version TM-21 Lumen Maintenance

(60,000 hours) (2)

Theoretical L70 (Hours) (3)

Standard > 85% > 151,000

High Efficiency > 90% > 203,000

Very High Efficiency > 90% > 203,000

Notes: (2) Supported by IES TM-21 standards. (3) Theoretical values represent estimations commonly used; however, refer to the IES position on LED Product Lifetime Prediction, IES PS-10-18, that explains proper use of IES TM-21 and LM-80.

Shipping Data

Catalog No. Wt.

Pallet

49"L x 52"W x 55"H

2' x 2' 12.5 lbs. 48

Load Data (Stock Product)

Thd 6%

Power Factor 0.99

Weight (lbs.) 10.6

Low Temp. Start -20ºC

Very High Efficacy Versions – Three Rows of LEDs

Catalog Number Lumens Watts lm/W

22CZ2-20VHE-UNV-L835-CD1-U 2008 14.2 141

22CZ2-24VHE-UNV-L835-CD1-U 2501 17.5 143

22CZ2-29VHE-UNV-L835-CD1-U 3114 21.7 144

22CZ2-34VHE-UNV-L835-CD1-U 3598 25.1 143

22CZ2-39VHE-UNV-L835-CD1-U 4078 28.6 143

22CZ2-44VHE-UNV-L835-CD1-U 4620 32.6 142

22CZ2-50VHE-UNV-L835-CD1-U 5095 36.2 141

22CZ2-55VHE-UNV-L835-CD1-U 5530 39.4 140

22CZ2-60VHE-UNV-L835-CD1-U 6110 44.1 139

22CZ2-65VHE-UNV-L835-CD1-U 6559 47.9 137

22CZ2-70VHE-UNV-L835-CD1-U 7017 50.3 140

22CZ2-75VHE-UNV-L835-CD1-U 7557 54.7 138

22CZ2-80VHE-UNV-L835-CD1-U 8092 59.1 137

22CZ2-85VHE-UNV-L835-CD1-U 8615 63.6 136

22CZ2-90VHE-UNV-L835-CD1-U 9125 68.2 134

22CZ2-95VHE-UNV-L835-CD1-U 9610 72.7 132

22CZ2-100VHE-UNV-L835-CD1-U 10108 77.7 130

22CZ2-110VHE-UNV-L835-CD1-U 11065 87.7 126

Shielding

Lumen Adjustment Factors

S HRP SQR

1.05 0.80 0.96

Air Return Volume

Negative Static Pressure (Inches H2O)

Return Air Volume (CFM)

0.05 79

0.1 112

0.2 161

0.25 177

0.3 198

0.45 239

Lumen Calculator

CCT

Multiplier 80 CRI 90 CRI (1) BioUp Static

3000K 0.965 0.827 -

3500K 1.000 0.847 0.912

4000K 1.019 0.856 0.899

5000K 1.019 0.909 0.879

Notes: (1) Input wattages for 90 CRI versions may vary. Refer to published IES-format photometry or LM-79 reports for more details.

Example of Lumen Adjustment Calculation 22CZ2-32-UNV-L935-CD1-U at 90CRI at 3500K

Lumen Adjustment Factor = 0.845 Total Light Output =

3,280 lm x 0.845 = 2,772 lm Efficacy = = 103.8 lm/W2,772 lm

26.7W

Standard Efficacy Versions – Single Row of LEDs Default CCT/Lumen Setting: 3500K/Med

Catalog Number Lumens Watts lm/W

22CZ2-20-UNV-L835-CD1-U 2142 16.2 132

22CZ2-24-UNV-L835-CD1-U 2454 18.5 133

22CZ2-32-UNV-L835-CD1-U 3272 24.2 135

22CZ2-39-UNV-L835-CD1-U 3953 31 128

22CZ2-44-UNV-L835-CD1-U 4462 33 134

Submitted by Solus Lighting & Controls

Job Name:

Kellogg Creek WRRF Admin Bldg Remodel Architect: Deca Architecture (Portland) Engineer: KCL Engineering - Portland (Portland)

Catalog Number:

22CZ2-20-UNV-L835-CD1-U

Notes:

Type:

A1

Index Page5/8Submitted On: Dec 22, 2025

PS519305EN page 6 December 9, 2025 3:01 PM

The Cruze ST with WaveLinx offers no-hassle lighting control with multiple luminaire level control solutions.

WaveLinx PRO is a wireless lighting control solution, for connected spaces, that significantly reduces a building’s energy consumption. From a single floor to an entire campus, WaveLinx PRO connects more than lighting assets; it shares aggregated sensor data with the WaveLinx CORE platform and other building systems, so building owners can improve operations, spaces environment, and tenants' experience. WaveLinx PRO offers a rich portfolio of wireless devices, WaveLinx PRO-enabled luminaires, and an intuitive WaveLinx mobile app for office, education, warehouse, and parking garage applications.

WaveLinx LITE is a cost effective, wireless digital lighting control solution, with out-of-the-box functionality, that saves energy and meets code. It’s designed for applications that require occupancy-based, daylighting, or manual light control.

Customize installations for office, education, warehouse and parking garages using the secure, simple mobile app.

Systems comparison chart Cooper Lighting Solutions provides many lighting system solutions designed to satisfy code requirements and meet the unique needs of any project.

Note: Installation of integrated sensors within 3-ft (1m) of HVAC air vents is not recommended. The pattern shown is intended solely as a general guide and is not to scale.

Integrated Sensor Coverage Pattern

Control Solutions

•WaveLinx LITE wireless
•WaveLinx PRO wireless
•WaveLinx CAT wired
•WaveLinx Wired

With Integrated WaveLinx Sensor

With Integrated WaveLinx Node

Luminaire with Standalone Standalone Networked Enterprise standalone Spaces Spaces Spaces WaveLinx sensor WaveLinx LITE WaveLinx CAT WaveLinx PRO CORE

Occupancy Yes Yes Yes Yes Yes

Daylighting Yes Yes Yes Yes Yes

Wallstations – Yes Yes Yes Yes

Gateways – – – 1 WAC 300 WACs

Devices (MAX) – 40 per Area (1120 per space) 40 per Area 200 per WAC2 32,500 per CORE Enterprise

Software – WaveLinx LITE Mobile App WaveLinx CAT Mobile App WaveLinx Mobile App CORE

Areas – 28 per Space Unlimited 50 per WAC2 up to 3,000

Zones – 16 per Area 16 per Area 16 per Area up to 9,000

Scheduling – – – Local Global

VividTune™ – – – Yes Yes

Plug-Load Control – Yes Yes Yes Yes

Low-Voltage Power – – Yes Yes Yes

Integration – – – – BACnet, API

Dashboards – – – – Energy, Occupancy

Configuration – Installer Installer Technician Technician / IT

SCALABILITY

WaveLinx expands from a single standalone device up to Enterprise with 32,500 devices devices areas floors buildings

2.4m (8ft)

0m (0ft)

4.5m (15ft)

4.5m

(15FT)

0m (0ft)

CL

4.5m

(15FT)

4.5m

(15FT)

0m (0ft)

CL

2.25m

(7.5FT)

2.25m (7.5ft)

3.0m (10ft)

4.5m

(15FT)

TOP VIEW:

SIDE VIEW:

Note: The "beam" pattern obtained depends strongly on the detector used with this array. The pattern shown is intended solely as a general guide and is not to scale.

2.4m (8ft)

0m (0ft)

4.5m (15ft)

4.5m

(15FT)

0m (0ft)

CL

4.5m

(15FT)

4.5m

(15FT)

0m (0ft)

CL

2.25m

(7.5FT)

2.25m (7.5ft)

3.0m (10ft)

4.5m

(15FT)

TOP VIEW:

SIDE VIEW:

Note: The "beam" pattern obtained depends strongly on the detector used with this array. The pattern shown is intended solely as a general guide and is not to scale.

Allows to:

•Keeps luminaire aesthetics
•Connect fixtures without the
realestate to include sensor
option such as downlights
•Connect sealed fixtures
without a standard sensor
option such as products for
clinical space.

LITE

WaveLinx

PRO

WaveLinx

Add a hidden WaveLinx sensor node (WPN, WLN) to your space lighting design!

Integrated Controls Options

Option Out of the Box Functionality

Luminaire Level Lighting Control

(LLLC)

Automatic Dimming Photocell

Occupancy Sensing

CCT

Control*

WLS X X X X

WLN X

WPS X X X X

WPN X X

Note: *WaveLinx utilizes scenes to allow users to change an area’s fixtures Correlated Color Temperature (CCT) and intensity using a commissioned wireless wallstation scene controller. To enable CCT adjustments through WaveLinx, include WPS or WPN devices in addition to VividTune or BioUp technologies for integrated fixture control. WPS with CCT controls the intensity of the fixture;

an additional, externally mounted control device is needed to control the CCT. See RSP-P-010-347 The WNPS option is available with WLS or WPS sensors. Must be specified when ordered. Also note that WLS and WPS are also compatible with ESP-L-010-347 and ESP-P-010-347, respectively. Learn more about WaveLinx EM here.

Submitted by Solus Lighting & Controls

Job Name:

Kellogg Creek WRRF Admin Bldg Remodel Architect: Deca Architecture (Portland) Engineer: KCL Engineering - Portland (Portland)

Catalog Number:

22CZ2-20-UNV-L835-CD1-U

Notes:

Type:

A1

Index Page6/8Submitted On: Dec 22, 2025

PS519305EN page 7 December 9, 2025 3:01 PM

22 Cruze ST LED with VividTune Tunable White VividTune tunable white luminaires from Cooper Lighting Solutions deliver high-quality light in a broad range of continuously variable color temperatures and intensities. Create a dynamic environment by adjusting the ambient light warmer or cooler to influence mood, support the task at hand, or create a dramatic ambience. The ability to control correlated color temperature and intensity separately using simple controls is the next evolution of LED lighting for the commercial, educational, healthcare and hospitality space. The unparalleled flexibility and number of available lighting environments enable users to find the right light with tunable white.

Example of Lumen Adjustment Calculation

22CZ2-34HE-UNV-L83050-W2A1-U

at 80 CRI tuned to 3500K

Adjusted Lumen = published lm x adjusted lm factor

Adjusted Lumen = 3386 x 0.946

Adjusted Lumen = 3202 lm

* Lumen adjustment factors are for reference and may be different for each product selected.

Refer to IES files for actual performance data on each.

Tunable White - Lumen Adjustment Factors

CCT

VividTune 3000K-5000K

VividTune 2700K-6500K

BioUp Tunable White 2700K-5000K

80 CRI 90 CRI 80 CRI 90 CRI CRI Lumen Adjustment

2700K - - 0.903 0.771 95 0.938

3000K 0.929 0.765 0.928 0.801 94 0.929

3500K 0.983 0.836 0.961 0.842 90 0.912

4000K 1.033 0.903 0.981 0.868 87 0.899

4500K 1.042 0.918 0.999 0.891 85 0.890

5000K 1.042 0.918 1.013 0.909 84 0.879

6500K - - 1.028 0.933 - -

2' x 2' Cruze ST LED - Example of Approximate Lumen Calculation

Standard Catalog #

VividTune 80 CRI Catalog #

VividTune 90 CRI Catalog #

BioUp Tunable White

CCT

Setting

22CZ2-34HE-UNV-

L835-CD1-U

22CZ2-34HE-UNV-

L83050-W2A1-U

22CZ2-34HE-UNV-

L93050-W2A1-U

22CZ2-34HE-UNV-

B2750-W2A1-U

2700K - 3058 2611 3176

3000K - 3026 2491 3146

3500K 3386 3202 2722 3088

4000K - 3362 2940 3044

4500K - 3394 2991 3014

5000K - 3394 2991 2976

6500K - 3481 3159 -

Controlling VividTune and BioUp Tunable White From wall dimmers to wireless controls, tunable white luminaires are compatible with industry standard 0-10V and DALI controls. One channel to control intensity (brightness) and a second channel to adjust CCT.

warm 2700K cool 6500KCCT 0-10V warm 2700K cool 5000KCCT warm 3000K cool 5000KCCT 0-10V

10% 100%Intensity 0-10V

Energy and Performance Data

Submitted by Solus Lighting & Controls

Job Name:

Kellogg Creek WRRF Admin Bldg Remodel Architect: Deca Architecture (Portland) Engineer: KCL Engineering - Portland (Portland)

Catalog Number:

22CZ2-20-UNV-L835-CD1-U

Notes:

Type:

A1

Index Page7/8Submitted On: Dec 22, 2025

Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com

© 2025 Cooper Lighting Solutions All Rights Reserved.

Specifications and dimensions subject to change without notice.

PS519305EN page 8 December 9, 2025 3:01 PM

BioUp enhances the LED spectrum with cyan light at 475nm increasing the biological impact of the light to enhance our circadian rhythm which regulates our sleep/ wake cycle, daytime engagement, and mood – all without distorting visual color impression.

Standard 4000K LED

MDER = .62

380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720

Lamp Data Melanopic Visual 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720

Lamp Data Melanopic Visual

BioUp 4000K LED

MDER = .82

› Control with Wavelinx, 2ch 0-10V, or DALI 0% 100%Intensity warm 2700K cool 5000KCCT

0% 100%Intensity warm 2700K cool 5000KCCT

› no CCT control needed

Dimming Control 0% 100%Intensity warm 2700K cool 5000KCCT

Dimming Control

CCT

Control

See better Feel better Function better

ANSI/IES RP-46-23

/ TM18 published March 2024 based on over 40 years of research.

“…circadian clock synchronization is paramount to the body’s efficient and appropriate functioning.” – TM18

Use BioUp to achieve Equivalent Melanopic Lux (EML) thresholds for circadian design and earn nearly 20% of WELL building lighting points.

48"

150 EML

136 Melanopic-EDI

48"

275 EML

250 Lux M-EDI

48"

180 EML

163 M-EDI

30% boost Biological impact compared to traditional LED sources

MDER, M-EDI and EML are key metrics used to quantify non-visual performance of indoor lighting systems.

MDER - Melanopic Daylight Efficacy Ratio (MDER) measures the amount of light stimulating to the melanopsin receptors.

www.ies.org

RECOMMENDED PRACTICE:

SUPPORTING THE PHYSIOLOGICAL

AND BEHAVIORAL EFFECTS

OF LIGHTING IN INTERIOR

DAYTIME ENVIRONMENTS

AN AMERICAN NATIONAL STANDARD

ANSI/IES RP-46-23

Accessed by account: Signify | User: Kelly Seeger | Date: Thu Mar 07 15:35:34 UTC 2024 | IP address: 136.226.74.169

ANSI/IES RP-46-23

Static BioUp is used when simple Melanopic Lighting is desired at all times.

Dynamic BioUp is used when Melanopic Lighting is desired to adjust during the day.

Proven Research. Industry Recognized.

Cyan light component always present

3500K 4000K 5000Kor or

380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720

Lamp Data Melanopic Visual 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720

Lamp Data Melanopic Visual 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720

Lamp Data Melanopic Visual

MDER = 0.71

Dynamic - (Tunable)Static (non-tunable)

380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720

Lamp Data Melanopic Visual 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720

Lamp Data Melanopic Visual

CCT

LED MDER

~83 CRI

BioUp Static BioUp Dynamic

MDER CRI MDER CRI

2700K 0.44 – – 0.43 95

3000K 0.49 – – 0.54 94

3500K 0.56 0.71 90 0.71 90

4000K 0.64 0.84 87 0.82 87

5000K 0.77 0.98 84 0.98 84

2700K – 5000K

Warmer CCT Without Cyan content

MDER = 0.84 MDER = 0.98 MDER = 0.43 MDER = 0.98

Evening

Cooler Light With Cyan content

Daytime

BioUp Melanopic Lighting

Darker Nights

Brighter Days

See BioUp brochure for more details

BioUp solutions maximize WELL points for Circadian Lighting Design (L03):

Arrow in graph shows BioUp spectrum boost is at 475nm where non-visual biological response is enhanced.

The power of healthy daytime lighting in indoor settings Melanopic lighting advances and office applications

See BioUp white paper for more details

BioUp Melanopic Lighting

Submitted by Solus Lighting & Controls

Job Name:

Kellogg Creek WRRF Admin Bldg Remodel Architect: Deca Architecture (Portland) Engineer: KCL Engineering - Portland (Portland)

Catalog Number:

22CZ2-20-UNV-L835-CD1-U

Notes:

Type:

A1

Index Page8/8Submitted On: Dec 22, 2025

Date: To:

A/E Project Number:

Contract For: Re:

© Copyright 2007, Construction Specifications Institute, 110 South Union Street, Suite 100, Alexandria, VA 22314

This is not an official CSI Construction Contract Administration (CCA) Form. Please use CSI's official CCA Forms if required by your project needs.

Trade Name: Model No.:

Attached data includes product description, specifications, drawings, photographs, and performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified.

Attached data also includes a description of changes to the Contract Documents that the proposed substitution will require for its proper

• Proposed substitution has been fully investigated and determined to be equal or superior in all respects to specified product.

• Same warranty will be furnished for proposed substitution as for specified product.

• Same maintenance service and source of replacement parts, as applicable, is available.

• Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule.

• Proposed substitution does not affect dimensions and functional clearances.

• Payment will be made for changes to building design, including A/E design, detailing, and construction costs caused by the

Substitution approved - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures.

Substitution approved as noted - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures.

Supporting Data Attached: Drawings Product Data Samples Tests Reports

Deca Architecture Inc 12/22/2025

KCL Engineering

Lighting Substitution

Lighiting

All

Rochelle Montgomery

Rochelle Montgomery

26 00 00

Lighting All

Solus Lighting & Controls

1820 E Burnside St

Portland, OR 97214

503-768-9999

Submitted by Solus Lighting & Controls

Job Name:

Kellogg Creek WRRF Admin Bldg Remodel Architect: Deca Architecture (Portland) Engineer: KCL Engineering - Portland (Portland)

Catalog Number:

SUBSTITUTION REQUEST FORM

Notes:

Type:

MISC

PS519305EN page 1 December 9, 2025 3:01 PM

Project Catalog # Type

Prepared by Notes Date

Top Product Features

•Latch-less design provides clean architectural look
•BioUp melanopic lighting options for 30% circadian boost and earn WELL Building Standard points
•VividTune CCT tuning options from 3000K-5000K or 2700K-6500K
•Designers delight - ribbed, smooth and round perforated lens options
•High performance efficacy up to 151 lm/W
•Integrated sensor systems - occupancy, daylight and IoT connectivity
•Options to meet Build America, Buy America, Buy American and other domestic preference requirements

Dimensional and Mounting Details

Cruze ST 22CZ2

2' x 2' LED Specification Grade Troffer

Typical Applications

Office • Education • Healthcare • Hospitality • Retail

Ceiling Trim Type Type Exposed Grid Standard Concealed T Standard Slot Grid Standard Flange *

G Grid/Lay-in Standard

G Concealed T

G Slot Grid

*See Drywall Frame Kit Accessory in Ordering Information Section

Ceiling Compatibility

Interactive Menu

• Order Information page 2

• Photometric Data page 3

• Control Solutions page 5

• VividTuneTM Color Tuning Solutions page 6

• BioUp - Melanopic Lighting page 7

• Product Warranty

3-1/4" [83mm]

23-3/4" [603mm]

7" [179mm]

23-3/4" [603mm]

15-3/4" [401mm] 23-3/4" [603mm]

5-1/2" [142mm]

Shielding

HRP - High-Efficiency Round Perf Inlay

See ordering information for more shielding options.

SQR - Square Ribbed Frosted Acrylic Lens

AVAIL ABL E

CO

MPLIANT OPTIONS

BABA

BUILD AMERICA

BUY AMERICA

Product Certification

Product Features

Designed to provide safe and convenient means of disconnecting power

LITE

WaveLinx

PRO

WaveLinx BioUp

Melanopic Lighting

Submitted by Solus Lighting & Controls

Job Name:

Kellogg Creek WRRF Admin Bldg Remodel Architect: Deca Architecture (Portland) Engineer: KCL Engineering - Portland (Portland)

Catalog Number:

22CZ2-20-UNV-XX-L835-CD1-U

Notes:

Type:

A1E

PS519305EN page 2 December 9, 2025 3:01 PM

Order Information

SAMPLE ORDER NUMBER: 22CZ2-34HE-UNV-L835-CD1-U

Domestic Preferences (1) Rating Series Air Lumen Level / Efficacy Option

[Blank]=Standard BAA=Buy American Act TAA=Trade Agreements Act BABA=Build America Buy America Act

[Blank]=Standard

ATW-SW4=

Chicago Rated

22CZ2=2x2 Cruze ST

[Blank]=Standard A=Air (Vented) (2)

Standard [Blank] 20=2000 Lumens (4)

24=2400 Lumens (4)

32=3200 Lumens (3)

39=3900 Lumens (3)

44=4400 Lumens (3)

High Efficacy [HE] (4), (5)

20HE=2000 Lumens 24HE=2400 Lumens 29HE=2900 Lumens 34HE=3400 Lumens 39HE=3900 Lumens 44HE=4400 Lumens

Very High Efficacy [VHE] 20VHE=2000 Lumens 24VHE=2400 Lumens 29VHE=2900 Lumens 34VHE=3400 Lumens 39VHE=3900 Lumens 44VHE=4400 Lumens 50VHE=5000 Lumens 55VHE=5500 Lumens

60VHE=6000 Lumens (5)

65VHE=6500 Lumens (5)

70VHE=7000 Lumens (3), (6)

75VHE=7500 Lumens (3), (6)

80VHE=8000 Lumens (3), (6)

85VHE=8500 Lumens (3), (6)

90VHE=9000 Lumens (3), (6)

95VHE=9500 Lumens (3), (6)

100VHE=10000 Lumens (3), (6)

110VHE=11000 Lumens (3), (6)

Notes Notes Notes

(1) Only product configurations with these prefixes are built to be compliant with the Buy American Act of 1933 (BAA), Trade Agreements Act of 1979 (TAA), or the Build America Buy America Act (BABA). BABA is the minimum Government compliance requirement for the Build America Buy America standards which is part of the Infrastructure and Investment Jobs Act (IIJA). Individual Government Agencies may have more stringent compliance standards. Please refer to DOMESTIC PREFERENCES website or consult the CLS Domestic Preferences team for more information. Components shipped separately may be separately analyzed under domestic preference requirements.

(2) Air version is intended for air return through plenum. See air return data table for air flow volumes.Air option not available with ATW-SW4. Air requires “PAF” option.

(3) VividTune white tuning and BioUp static and dynamic options are not available with these lumen/efficacy selections. (4) BioUp lumen option. (5) Vividtune lumen option. (6) Available with CD and HCD drivers only.

Shielding Voltage (5) Options Emergency Options

[Blank]=Ribbed Frosted Acrylic Lens (standard) S=Smooth Frosted Acrylic Lens HRP=High-Efficiency Round Perf Inlay SQR=Square Ribbed Frosted Acrylic Lens

UNV=Universal Voltage 120-277 347V=347 Volt

GL=Single Element Fuse GM=Double Element Fuse PAF=Painted After Fabrication

[Blank]=No emergency EL7W=7-watt 120V-277V emergency battery pack (6)

EL10W=10-watt 120V-277V emergency battery pack (6)

EL14W=14-watt 120V-277V emergency battery pack (6)

EL10WSD=10W emergency battery pack with self-diagnostic installed (6), (8)

EL14WSD=14W emergency battery pack with self-diagnostic installed (6), (8)

ETRD=Emergency Transfer Relay with dimming control (7)

RRU=LVS Controls Emergency Transfer Relay with dimming control (7)

UEL7W=UL924 Listed luminaire, 7-watt, 120V-277V emergency battery pack (6), (10)

UEL14W=UL924 Listed luminaire, 14-watt 120V-277V emergency battery pack (6), (10)

UEL10WSD=Bodine 10W emergency battery pack with self diagnostic installed (6), (9), (10)

UETRD=UL924 Listed luminaire, Emergency Transfer Relay with dimming control (7), (10)

URRU=UL924 Listed luminaire, LVS Controls Emergency Transfer Relay with dimming control (7), (10)

WNPS=WaveLinx wireless Normal Power Sensing (NPS) capable device (23)

Notes Notes

(5) Products also available in non-US voltages and frequencies for international markets.

(6) Factory installed with integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available. Battery option increases total height by 1 inch. (7) Used to bypass local control during outage. Must be used in conjunction with UL 1008 device (provided by others). Devices are universal voltage (UNV). 347 not available. (8) EL10WSD and EL14WSD not available with 347V. (9) UEL10WSD not available with 347V. (10) Cannot be used with BioUP options. (23) Must be ordered with WLS or WPS sensor. WNPS cannot be ordered with emergency or relay options such as ETRD, GTR2, ELxxx or GTDU.

CRI/CCT Flex

L830=80CRI, 3000K

L835=80CRI, 3500K

L840=80CRI, 4000K

L850=80CRI, 5000K

L930=90CRI, 3000K

L935=90CRI, 3500K

L940=90CRI, 4000K

L950=90CRI, 5000K

L83050=80CRI 3000K-5000K White Tuning (12)

L93050=90CRI 3000K-5000K White Tuning (12)

L82765=80CRI 2700K-6500K White Tuning (12)

L92765=90CRI 2700K-6500K White Tuning (12)

B35=BioUp Static 3500K (13)

B40=BioUp Static 4000K (13)

B50=BioUp Static 5000K (13)

B2750=BioUp Tunable 2700K-5000K (14)

[Blank]=No Flex A3/8-4/18GDIM=3/8" Flex with 0-10V Dimming Leads A3/8-2/18G=3/8" Flex with line and common A3/8-5/18GDIM=Flex with 0-10V Dimming leads and Blue for alternate wiring. See below for details.

Notes

(12) VividTune provides correlated color temperatures (CCT) between 3000K (warm) to 5000K (cool) or 2700K (warm) to 6500K (cool). Must be used in conjunction with W2A driver only. Must be used with two (2) 10V dimming control channels, 1 cct, 1 intensity. May be combined with Wavelinx sensor control systems. (13) BioUp Static to be used with HCD driver. (14) BioUp Tunable provides correlated color temperatures (CCT) between 2700K (warm) to 5000K (cool). Must be used with W2A (for two channel 0-10V Control) or W2D (for 2 channel Dali Control) driver. See BioUp page for more information.

Flexible Metal Conduit Options

Flex options available for 0-10V dimming control, DALI dimming control, emergency and night light functions. 72-inch factory-installed and pre-wired to driver, fitted to luminaire housing access plate with 90° enclosed FMC connector. Not all options may be combined and installation ratings vary by type.

See online configurator for all flex options.

A3/8-4/18GDIM series notes: Factory installed dimming option 3/8” flexible metal conduit with 2-#18 power and ground wires and 2-#18 UL-listed jacketed 0-10V +/- control wires. Meets UL 66, 83, 1479, 1569, 1581, 2556. NEC® 250.118, 300.22(C), 392, 396, 330, 501, 502, 503, 530, 504, 505, 518, 520, 530, 645, 72; Federal Specification A-A-59544 (formerly J-C-30B); all applicable OSHA and HUD Requirements. UL Classified 1-, 2-, and 3-hour through penetration with applicable fire stop product (not included). May be surface mounted, fished and/or embedded in plaster. Cable tray and approved raceway rated, install per NEC®; Environmental Air-Handling Space Installation per NEC® 300.22(C).

continued next page

Submitted by Solus Lighting & Controls

Job Name:

Kellogg Creek WRRF Admin Bldg Remodel Architect: Deca Architecture (Portland) Engineer: KCL Engineering - Portland (Portland)

Catalog Number:

22CZ2-20-UNV-XX-L835-CD1-U

Notes:

Type:

A1E

SOLUS25-224731

CONFIRM

PS519305…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .