BFMS WEST GEN DRAWINGS.pdf
PDF 1 MB Posted
- Solicitation number
- IFB-120050
- Issued by
- Floyd County, Virginia
About this file
This is a set of general drawings for a Whole Building Generator Installation project at Benjamin Franklin Middle School West in Virginia (Bid No. 06022026-1400). The project involves the installation of a 1,000 KVA diesel generator system with associated infrastructure and components. Key deliverables include the generator unit, protective enclosure, lighting, electrical panelboard, receptacles, belly tank for fuel storage, fuel polisher, automatic control kit, concrete pads, feeder circuits, branch circuits, conduit systems, grounding infrastructure, and interconnection equipment. The contractor is responsible for all equipment assembly and bolting to pads, diesel fuel supply, control equipment installation, wiring for 480V, 277V, and 120V systems, secondary wiring, conduit installation, site grading, trenching, backfill operations, generator-specific lighting and receptacles, panel labeling, system testing, and final setup and commissioning.
The drawings serve as the technical specifications and design reference for bidders to understand the scope of electrical and mechanical work required for the generator installation. The contractor must provide comprehensive labor and materials for all interconnections, equipment mounting, fuel provision, control systems, wiring infrastructure at multiple voltage levels, site preparation including grading and trenching, concrete work, and complete system testing and commissioning. These drawings establish the baseline technical requirements that all bidders must meet in their proposals for this infrastructure upgrade project at the school facility.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| BFMS WEST Gen Addendum 3.pdf | ||
| 005000.2025.0087.pdf | ||
| 010100.2025.0087.pdf | ||
| BFMS W GEN Specs UPDATED.pdf | ||
| ITB.2025.0087.pdf | ||
| BFMS WEST GEN DRAWINGS.pdf | ||
| 006800.2025.0087.pdf | ||
| BFMS WEST GENERATOR ADDENDUM 2.pdf | ||
| BFMS WEST Gen Addendum 1.pdf | ||
| 003000.2025.0087.pdf | ||
| 004100.2025.0087.pdf | ||
| 006200.2025.0087.pdf | ||
| 006100.2025.0087.pdf | ||
| BFMS W GEN Specs UPDATED.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C O M M O N
W E
AL
TH OF
V I
R G I N I A
P
RR
O F
E S S
I ON A L E N
G I
N E E
OVERALL LOCATION
ENGINEER
5228 VALLEYPOINTE PKWY, SUITE 4
ROANOKE, VIRGINIA 24019
(540) 265-4444
STRATUS®
LOCATION MAP
PROJECT SITE
R
RANDALL O. SPENCER
Lic No.029321
Stratus Project No.2025-0087
05/11/2026
FRANKLIN COUNTY PUBLIC SCHOOLS
225 MIDDLE SCHOOL RD
ROCKY MOUNT, VA 24151
BENJAMIN FRANKLIN MS WEST
GENERATOR PROJECT CODE
06022026-1400
ELECTRICAL SHEET INDEX
Sheet Number Sheet Name
T-1 TITLE SHEET
E0.1 ELECTRICAL DETAILS, LEGEND, AND SCHEDULES
E1.1 ELECTRICAL PARTIAL FLOOR PLAN
E2.1 ELECTRICAL PARTIAL POWER RISER
T-1
GENERAL NOTE:
DUE TO DIGGING NEAR UNDERGROUND UTILITIES CONTACT MISS UTILITY AT 811, 1-800-552-7001, OR HTTP://WWW.MISSUTILITYOFVIRGINIA.COM NO LESS THAN 72 HOURS PRIOR TO EXCAVATION
AND DO NOT DISTURB THE SOIL UNTIL DIG TICKET HAS BEEN PROCESSED.
CONTRACTOR SHALL ACQUIRE THE SERVICES OF A PRIVATE UTILITY LOCATION COMPANY TO
LOCATE ALL EXISTING UTILITIES IN THE AREA OF WORK.
PRIMARY CONTACTS:
OWNER - FRANKLIN COUNTY PUBLIC SCHOOLS
PROJECT MANAGER - JOSH TURNER
EMERGENCY MANAGEMENT COORDINATOR FRANKLIN COUNTY FIRE-EMS
1255 FRANKLIN STREET, SUITE 111,
ROCKY MOUNT, VA 24151
PHONE – 540-483-6624
EMAIL - josh.turner@franklincountyva.gov
PROJECT ELECTRICAL DESIGNER - RANDALL SPENCER, ELECTRICAL DESIGN ENGINEER
STRATUS
5228 Valleypointe Pkwy #4
ROANOKE, VA 24019
OFFICE -540-529-5014
EMAIL - randy.spencer@stratusteam.com
CODE REFERENCES:
1. VIRGINIA CONSTRUCTION CODE (VCC) 2021
2. VIRGINIA UNIFORM STATEWIDE BUILDING CODE (VUSBC) 2021
3. NFPA 70, NEC 2020
4. SEE SPECIFICATIONS FOR ADDITIONAL CODES.
STEEL AND CONCRETE BOLLARD DETAIL
0'-6"
MIN
'-6
M
IN
4-#8 w/#3 TIES
@ 12" O.C. MIN
PAVEMENT
BOLLARD - (STEEL TUBE .25" THICK, 6" DIA.)
'-0
CONCRETE FOOTER BASE SHALL
BE SET ON COMPACTED
SUBGRADE. BASE FOOTING
SHALL BE NO LESS THAN
24" ROUND MIN.
NO SCALE
2'-0"
MIN
CONCRETE FOOTER 24" IN DIA.,
36" TALL.
6" TALL CONCETE DOMED TOP
'-6
EMERGENCY GENERATOR PAD DETAIL
EMERGENCY GENERATOR
12"
MIN. EACH
SIDE
1'-6"
TYPICAL
CHAMFER
2"FINISHED GRADE
M
IN
12"
#4 REBAR EACH WAY @ 12"
ON CENTER TOP & BOTTOM
CLASS A-3 CONCRETE SLAB
COMPACTED GRANULAR
FILL VDOT TYPE 1 NO. 21
OR 21A AGGREGATE BASE
COMPACTED SUBGRADE
NO SCALE
GROUND ROD
(MIN 10'-0" BELOW GRADE)
BUILDING GROUNDING ELECTRODE SYSTEM (BGES)
#3/0 IN 3/4" CONDUIT UNLESS INDICATED
OTHERWISE
NOTES:
1. ALL CONNECTIONS IN THE GROUNDING ELECTRODE SYSTEM
SHALL BE EXOTHERMICALLY WELDED (CADWELD, NO
SUBSTITUTE).
2. BOND ALL GROUNDING ELECTRODE METALLIC RACEWAYS
PER NEC 250.64(B).
3. NEC 250.50 ALLOWS THE UNSPLICED GROUNDING
ELECTRODE CONDUCTOR TO BE RUN TO ANY OF THE ABOVE
CONVENIENT GROUNDING ELECTRODES IN THE GROUNDING
ELECTRODE SYSTEM. THEREFORE, ALL THE ABOVE
GROUNDING ELECTRODE CONDUCTORS SHALL BE SIZED PER
NEC 250.66 (TABLE) TO PERMIT THIS APPLICATION, UNLESS
INDICATED OTHERWISE ON POWER RISER DIAGRAM.
SCHEMATIC
GROUNDING RODS: THREE (3) OR FOUR (4) AS REQUIRED PER
SECTION 26 05 26
NEC 250.52(A)(5)
TYPICAL BUILDING GROUNDING
ELECTRODE PER SPECIFIED
SYSTEMS, ETC.
TO THE MAIN SERVICE ENTRANCE
EQUIPMENT (I.E. MAIN PANEL)
SIZE PER NEC 250.66(TABLE) UNLESS
INDICATED OTHERWISE ON POWER RISER
DIAGRAM.
COLD WATER AND SPRINKLER MAINS
BUILDING METAL FRAME NOT
INTENTIONALLY OR INHERENTLY
GROUNDED
NEC 250.104(C)NEC 250.104(B)
"OTHER" METAL PIPING & DUCT
WORK BONDED TO BGES AS
INDICATED
NEC 250.66
NEC 250.52(A)(1)
NEC 250.104(A)
INTERIOR METAL WATER
PIPING BONDED TO BGES
NEC 250.52(A)(2)
BUILDING METAL FRAME
WHERE EFFECTIVELY
GROUNDED
NEC 250.52(A)(3)
BUILDING CONCRETE
ENCASED REINFORCEMENT
STEEL SEE NOTE 3
'-0
" M
IN
10'-0" MIN
10'-0" M
IN
GENERATOR
GROUND ROD
AND ADD WIRING
TO EXISTING BGES
#250
DUCT BANK SECTION
4"
4" -1
/2
7-1/2"
4" PVC
TYPICAL OF 8
NO SCALE
NOTES:
1. MINIMUM COVER ABOVE DUCTBANK OF
COMPACTED BACKFILL SHALL BE 34" FOR
GENERATOR CIRCUITS UNLESS OTHERWISE
INDICATED ON CIVIL PROFILES.
2. PROVIDE #10 CRUSHED STONE, COMPACTED
FOR BEDDING UNDER DUCTBANK.
3. PROVIDE MARKER TAPE CENTERED ABOVE
DUCTBANK. MARKER TAPE SHALL RUN THE
LENGTH OF THE DUCTBANK.
4. PROVIDE ONE (1) #4 REBAR AT EACH CORNER
AND ONE (1) #3 TIES IN TWO PIECES AT 24" ON
CENTER ALONG DUCTBANK.
ELECTRICAL SYMBOLS
DESCRIPTIONSYMBOL
SYSTEM AFF TOP OF
OUTLET
UNLESS
NOTED
E L E
C T
R
IC
A L E
L E
M E
N T
S
EXISTING VARIABLE FREQUENCY DRIVE
EXISTING ELECTRICAL PANEL, SURFACE MOUNT.PNL
EXISTING ELECTRICAL PANEL, FLUSH MOUNT.
EXISTING UNDERGROUND ELECTRICAL PRIMARY
PNL
VFD
EUEP
UGP
EUES
EXISTING DISCONNECT SWITCH
UNDERGROUND GENERATOR POWER
EXISTING UNDERGROUND ELECTRICAL SECONDARY
GROUNDING ELECTRODE
EXISTING DUPLEX RECEPTACLE, WALL
EQUIPMENT BOX AS NOTED ON PLANS
EGS EMERGENCY GENERATOR SHUTDOWN4'-0"
EGS EMERGENCY GENERATOR SHUTDOWN WITH WEATHERPROOF COVER.
WL4'-0"
UE UNDERGROUND ELECTRICAL AUXILIARY GENERATOR POWER
UC UNDERGROUND COMMUNICATIONS FOR GENERATOR
C O M M O N
W E
AL
TH OF
V I
R G I N I A
P
RR
O F
E S S
I ON A L E N
G I
N E E
A
ALL RIGHTS RESERVED. THESE DRAWINGS AND SPECIFICATIONS ARE
INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF
STRATUS®. WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS
EXECUTED OR NOT. THEY ARE NOT TO BE USED IN ANY MANNER ON OTHER
PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY THE AGREEMENT
IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO STRATUS®.
REPRODUCTIONS OF SPECIFICATIONS WITHOUT THE WRITTEN CONSENT
OF STRATUS® IS PROHIBITED.
COPYRIGHT 2025 STRATUS
R
Seal
82 3 4 5 6 7
H
B
C
D
E
F
G
1 82 3 4 5 6 7
RANDALL O. SPENCER
Lic No.029321
5/ 8/
1:
:1
A
M A ut od es k
D oc s:
//2
6-
B en ja m in F ra nk lin M
S G en er at or
/2
6-
M
E P
C en tr al v
.r vt
E0.1
E L
E C
T R
IC
A
L D
E T
A
IL
S L
E G
E N
D A
N D
S C
H E
D U
L E
S
05/11/2026
B E
N J
A M
IN
F
R A
N K
L
IN
M S
W E
S T
G E
N E
R A
T O
R
P R
O J
E C
T C
O D
E
-1
SUBMISSION
2025-0087
M
ID
D
LE
S C
H O
O L
R D
R O
C K
Y M
O U
N T
V
A
F R
A N
K L
IN
C
O U
N T
Y P
U B
L
IC
S C
H O
O L
S
D E
S
IG
N E
R : R
O S
D R
A F
T E
R
S
JH
C H
E C
K E
R : R
O S
V A
LL
E
Y P
O
IN
T E
P K
W Y
, S T
E
R O
A N
O K
E , V
A
R E
V
D A
T E
N
O T
E
PNL-G
BOILER ROOM
BOYS
MECHANICAL
ROOM
GIRLS
JAN
EWH-2
CP-2W
VFD VFD VFD VFD
PNL-CDP
-MB
-DIST 2
480V-3ø-2500 AMPS
EXISTING SWITCHBOARD
EXISTING SWITCHBOARD
208-3ø-2000 AMPS
EXISTING
TRANS
480/208V- 3ø-500
KVA
E
PNL-WHM1
CP-1W
WHM1-29,31,33
EXISTING
MTS
AMPS
NORM
PWR
2500 A
GEN
PWR
2500 A
GEN
CABLE
AREA
EX - CT
CABINET
EXISTING
PWR. CO.
TRANS &
PAD
EXISTING CHILLER, FENCE AND GRAVEL AREA
NEW DIESEL GENERATOR
480V-3ø-1000 KW WITH
3000 GALLON DIESEL BELLY
TANK, FUEL POLISHER AND
CONCRETE PAD. SEE SPECS
FOR ADDITION INFORMATION.
PAD
TANK
GENERATOR
EUEP = EXISTING UNDERGROUND POWER COMPANY PRIMARY
EUES = EXISTING UNDERGROUND POWER COMPANY SECONDARY
UGP = UNDERGROUND GENERATOR POWER
UE = UNDERGROUND ELECTRIC
UC = UNDERGROUND COMMUNICATION FOR GENERATOR
EUEP
UGP
EU
ES
EXISTING ROADWAY
EXISTING WALKWAY
EXISTING GRASS AREA
EXISTING GRASS AREA
FENCE
STONE OR ROCK COVER
DDC
EXISTING PARKING EXISTING PARKING
E
E
E E
EE
E
E
E
EWH-1
EUH-1
E
EEEE
E E
E
E
GF-2
CWP-1W CWP-2W
EGS
EGS
WL
UC
UE
777 2
3 4 5 6 1
AIRFLOW
AND EXHAUST
TYPICAL FOR (14) BOLLARDS - SEE
DETAIL ON SHEET E0.1
C
OM
MO
NW
EA
LTH OF
V I RG
I N I A
P RR
O
F E S S I ON A L E N
G I
N E E
A
ALL RIGHTS RESERVED. THESE DRAWINGS AND SPECIFICATIONS ARE
INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF
STRATUS®. WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS
EXECUTED OR NOT. THEY ARE NOT TO BE USED IN ANY MANNER ON OTHER
PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY THE AGREEMENT
IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO STRATUS®.
REPRODUCTIONS OF SPECIFICATIONS WITHOUT THE WRITTEN CONSENT
OF STRATUS® IS PROHIBITED.
COPYRIGHT 2025 STRATUS
R
Seal
82 3 4 5 6 7
H
B
C
D
E
F
G
1 82 3 4 5 6 7
RANDALL O. SPENCER
Lic No.029321
5/8 /20
:41 :31
P M
Au tod es k D oc s:/
/20
-0
7 B en jam in
Fr an kli n M
S Ge ne ra tor /20
-0
7 M
EP
C en tra l v
.rv t
E1.1
EL
EC
TR
IC
AL
P
AR
TI
AL
F
LO
OR
P
LA
N
05/11/2026
BE
NJ
AM
IN
F
RA
NK
LI
N
MS
W
ES
T
GE
NE
RA
TO
R
PR
OJ
EC
T
CO
DE
-1
SUBMISSION
2025-0087
5 M
ID
DL
E
SC
HO
OL
R D
RO
CK
Y
MO
UN
T, V A
FR
AN
KL
IN
C
OU
NT
Y
PU
BL
IC
S
CH
OO
LS
DE
SI
GN
ER
: R
OS
DR
AF
TE
R:
S
JH
CH
EC
KE
R:
R
OS
SCALE:E1.1 1/4" = 1'-0"
1 FIRST FLOOR - ELECTRICAL PARTIAL POWER PLAN - MAIN ELECTRICAL RM AND YARD
GENERAL NOTES THIS SHEET:
1. ALL UNDERGROUND UTILITIES SHALL BE MARKED BY AN INDEPENDENT
MARKING COMPANY. MS UTILITY WILL NOT MARK ALL UNDERGROUND
UTILITIES.
2. PROVIDE THREE RELAYS IN GENERATOR TO MONITOR
RUN/STOP/FAILURE AND CONNECT RELAY OUTPUTS TO FIRE ALARM
PANEL IN MAIN FRONT OFFICE.
3. PROVIDE GEN STATUS FROM THE GENERATOR TO THE EXISTING DDC
SYSTEM IN THE ROOM NEXT TO THE MAIN ELECTRICAL MECHANICAL
ROOM.
E
NOTES THIS SHEET:
EMERGENCY GENERATOR STOP SWITCH (EGS) FOR GENERATOR
SHUTDOWN. WL INDICATED TO HAVE WEATHERPROOF COVER.
PROVIDE A PANDUIT PANZONE WALL MOUNTED ENCLOSURE WITH
WOODARD DTSC 200A CONTROLLER, 1000 WATT UPS, WITH 24 VDC POWER
SUPPLY TO POWER THE CONVERSION COMPONENTS TO MAKE THE MANUAL
TRANSFER SWITCHGEAR (MTU) AN AUTOMATIC TRANSFER SWITCHGEAR
(ATS). PROVIDE A RECEPTACLE IN THE ENCLOSURE TO POWER THE UPS.
POWER RECEPTACLE FORM EXISTING PANELBOARD CPD IN SAME ROOM.
PROVIDE A 120V-1ø-20 AMP BREAKER OF MATCHING FRAME AND SIZE IN
NEXT SPACE ONLY POSITION IN EXISTING PANELBOARD. THE CONTROLLER
SHALL MONITOR TWO (2) NEW VOLTAGE TRANSFORMERS TO BE INSTALLED
IN THE MTU AT EACH BREAKER (GEN POWER AND NORMAL POWER) TO
SIGNAL LOSS/RETURN OF NORMAL POWER AND GEN POWER
AVAILABLE/NOT AVAILABLE FOR POWER SEQUENCING OF THE TWO (2)
BREAKERS TO AUTOMATICALLY SWITCH FROM NORMAL POWER TO GEN
POWER AND BACK TO NORMAL POWER ON RESTORATION OF NORMAL
POWER. THE CONTROLLER SHALL MONITOR GENERATOR STATUS
(RUN/STOP/FAILURE) VIA RELAYS TO BE ADDED TO THE GENERATOR AND
REPORT SIGNALS TO THE FRONT OFFICE FIRE ALARM PANEL AND DDC
SYSTEM IN THE ROOM NEXT TO THE MAIN MECHANICAL/ELEC ROOM. 24VDC
POWER SUPPLY SHALL BE POWERED OFF OF THE USP AND PROVIDE
CONTROL AND SENSOR POWER TO THE DEVICES ADDED TO MTU TO
CONVERT IT TO AN ATS. THE CONTROLLER SHALL PROVIDE START AND
STOP SIGNALS TO THE GENERATOR. THE CONTROLLER SHALL RESPOND
TO TWO (2) NEW TEST SWITCHES TO BE ADDED IN THE MTU AT EACH
MOTORIZED BREAKER (GEN AND NORMAL POWER) FOR BREAKER
OPERATION TESTING.
PROVIDE TWO (2) TEST SWITCHES IN THE MTU.
PROVIDE TWO (2) VOLTAGE MONITORS (PT) IN THE MTU.
PROVIDE TWO (2) CONTROL POWER TRANSFORMER (CPT) IN THE MTU.
PROVIDE ONE (1) CONTROL POWER TRANSFORMER CONTACT (CPT/TO) IN
THE MTU.
THESE DRAWINGS ARE BASED ON HISTORICAL DRAWINGS OF THE
EXISTING BUILDING. CONTRACTOR SHALL VERIFY ALL CONDITIONS
PRIOR TO FABRICATION OF SYSTEM. MODIFICATIONS SHALL BE
MADE ONLY AFTER APPROVAL BY THE ENGINEER.
V
AL
LE
YP
OI
NT
E
PK
W Y, S
TE
RO
AN
OK
E, V
A
NOTES THIS SHEET:
REMOVE THE KIRK KEY INTERLOCK TO ALLOW THE SYSTEM TO
AUTOMATICALLY TRANSFER POWER SOURCE BASED ON LOSS OF NORMAL
POWER AND RETURN OF NORMAL POWER AND USE OF THE MANUAL TEST
SWITCHES. PROVIDE TWO TEST SWITCHES TO SIMULATE GENERATOR
TRANSFER CONDITIONS UNDER LOAD AND NOT UNDER LOAD. WIRE OPEN
AND CLOSE SIGNALS TO TEST SWITCH FOR CONTROLLER SIMULATION.
THE CABLE INPUT PANEL FOR A MOBILE GENERATOR SHALL STAY AND ADD
CABLING FROM THE CONTROL PANEL FOR A ROLL-UP GENERATOR START
CIRCUIT BE CONNECTED IF A ROLL-UP GENERATOR IS EVER NEEDED DUE
TO THE STATIONARY GENERATOR BEING OUT OF SERVICE.
PROVIDE A 1.5" CONDUIT FROM THE GENERATOR INTO THE CONTROL
CABINET IN THE MAIN MECHANICAL/ELEC ROOM FOR (STOP/START/STATUS),
GEN START, GEN STOP AND REMOTE GENERATOR MONITORING PANEL
CABLING.
PROVIDE A 208V-3ø-80 AMP BREAKER OF MATCHING FRAME IN EXISTING
PANEL CPD IN THE NEXT AVAILABLE SPACE ONLY 3 POLE POSITION. ONE (1)
1.25" CONDUIT FROM EXISTING PANEL CPD TO GENERATOR AND CONNECT
TO GENERATOR AUXILIARY POWER PANEL. CONNECT PANEL BUS TO
BREAKER WITH 4-#3 & 1-#8 EGC CONDUCTORS.
PROVIDE GROUND ROD AT GENERATOR PAD. GROUND / BOND GENERATOR
TO ROD. CONNECT ROD TO EXISTING BUILDING GROUNDING ELECTRODE
SYSTEM WITH #250 WIRE.
PROVIDE SILT TUBES, SOCKS AND RETAINAGE SCREENING FOR SEDIMENT
CONTROL AROUND ALL AREAS OF SOIL DISTURBANCE TO STOP THE
SPREAD FOR DIRT AND RUNOFF.
RESTORE GRADE AND SOIL TYPE TO DISTURBED AREAS.
SEED AND RESTORE GRASS TO ALL AREAS OF DISTURBED SURFACE.
BORE UNDER SIDEWALK FOR ALL CONDUITS.
GRAPHIC SCALE
8'4'02'4'
SCALE: 1/4" = 1'-0"
NOTES THIS SHEET:
CUT OUT PAD INSIDE CABINET TO ALLOW CONDUITS FROM THE
GENERATOR TO TURN UP IN COMPARTMENT TO ALLOW GEN CABLE TO
TERMINATE TO MTU GEN INPUT BUS TO LINE SIDE OF GEN BREAKER.
GENERATOR POWER CABLES 7(4-#500 & 1-#350 EGC IN 4" CONDUIT).
GENERATOR AUXILIARY POWER CIRCUIT 4-#3 & 1-#8 IN 1.25" CONDUIT.
EXISTING POWER COMPANY PRIMARY POWER CONDUCTORS TO
TRANSFORMER.
EXISTING SECONDARY POWER CONDUCTOR FROM TRANSFORMER.
AREA BETWEEN BUILDING AND CHILLER FOR EXISTING CHILLER PIPING.
RE
V:
DA
TE
NO
TE
#12 #10 #8 #6 #4 #4 #3 #2 #1
#1/0 #1/0 #3/0 #4/0 #250 #350 #500 #500 #4/0 #250 #350 #500 #350
#12 #10 #8 #6 #4 #4 #3 #2 #1
#1/0 #1/0 #3/0 #4/0 #250 #350 #500 #500 #4/0 #250 #350 #500 #350
#12 #10 #10 #10 #10 #8 #8 #8 #8 #6 #6 #6 #4 #4 #4 #3 #3 #2 #2 #1
#1/0 #1/0
3/4" 3/4" 3/4" 1"
1-1/4" 1-1/4" 1-1/4" 1-1/2" 1-1/2"
2" 2"
2-1/2" 2-1/2"
3" 3-1/2"
4" 4"
2-1/2" 3"
3-1/2" 4"
3-1/2"
DEVICE
RATING PHASE NEUT. EGC CONDUIT RUNS
BRANCH CIRCUIT
WIRE SIZE TABLE
NOTES:
1. WIRE SIZING IS BASED ON 2020 NEC TABLES 250.66
AND 310.15(B)(16).
2. DEVICE RATING REPRESENTS THE MAXIMUM SIZE
OVERCURRENT PROTECTION DEVICE FOR WHICH
THE ASSOCIATED WIRE MAY BE UTILIZED.
3. ALL FEEDER AND BRANCH CIRCUITS ON THIS
PROJECT SHALL CONTAIN NEUTRAL CONDUCTORS
UNLESS SPECIFICALLY STATED, BY THE
MANUFACTURER OF THE EQUIPMENT BEING SERVED,
THAT ONE IS NOT REQUIRED.
SCHEMATIC
PARTIAL POWER RISER DIAGRAM FOR ADDING GENERATOR
MECHANICAL/ELEC. RM. 021
EXISTING ELECTRIC METER
CABINET SURF. MOUNTED
DIST MB CT
EXISTING
480V-3ø-2500 AMP
SWITCHBOARD
GEN
CON BOX
SECTION
480V-3ø-
2500 AMP
EXISTING TRANSFER SWITCH 480V - 3ø - 2500 AMP
TO BE RETROFITTED TO BE AN ATS
GENERAL POWER NOTES THIS SHEET:
1. ALL CONDUIT AND WIRING UNLESS NOTED
OTHERWISE IS EXISTING TO REMAIN.
2. ALL EQUIPMENT UNLESS NOTED
OTHERWISE IS EXISTING TO REMAIN.
E3E
MANUAL
TRANSFER
SWITCH
SECTION
GEN
BREAKER
SECTION
CT
SECTION
GRADE
POWER RISER NOTE FOR NEW FEEDERS:
3-#12 AND 1-#12 EGC IN 3/4” CONDUIT
4-#3 AND 1-#8 EGC IN 1-1/4” CONDUIT)
7(4-#500 AND 1-#350 EGC IN 4” CONDUIT)
EXISTING POWER PRIMARY CABLING AND 4'
CONDUITS.
CONTROL / COMMUNICATION CONDUIT 1.5"
EXISTING CONDUIT AND WIRE.
E
E
POWER COMPANY
TRANSFORMER
12470/480V - 3ø - 2000 KVA
EXISTING
GRADE
NEW DIESEL GENERATOR
480V-3ø-1000.00 KW WITH
3000 GALLON BASE BELLY
TANK AND ONE (1) 1200 AMP
100% BREAKER WITH LSIG
MAIN
BREAKER
SECTION CHILLER
EXISTING
NEW GEN
CONDUIT
ENTRY
FOR BUXS
CONNECT
TO GEN
BREAKERX
480V-3ø-
2500 AMP
3000 GALLON BASE BELLY TANK
CONCRETE PAD
GEN AUX PANEL
EXISTING
CPD PANEL
CONTROL CABINET
FOR WOODARD
DTSC 200 A
CONTROLLER
E
NOTE THIS SHEET:
NEW GROUND ROD TIED TO BGES. SEE GROUNDING DETAILS.
EXISTING PANEL CDP. ADD ONE (1) 120V-1ø-20 AMP BREAKER AND ONE (1) 208V-3ø-80 AMP OF MATCHING FRAME AND SIZE.
PROVIDE A PANDUIT PANZONE WALL MOUNTED ENCLOSURE WITH WOODARD DTSC 200A CONTROLLER, 1000 WATT UPS, WITH 24 VDC POWER SUPPLY TO POWER THE CONVERSION COMPONENTS TO MAKE THE MANUAL TRANSFER SWITCHGEAR (MTU) AN AUTOMATIC TRANSFER SWITCHGEAR (ATS). PROVIDE A RECEPTACLE IN THE ENCLOSURE TO POWER THE UPS. POWER RECEPTACLE FORM EXISTING PANELBOARD CPD IN SAME ROOM. PROVIDE A 120V-1ø-20 AMP BREAKER OF MATCHING FRAME AND SIZE IN NEXT SPACE ONLY POSITION IN EXISTING PANELBOARD. THE CONTROLLER SHALL MONITOR TWO (2) NEW VOLTAGE TRANSFORMERS TO BE INSTALLED IN THE MTU AT EACH BREAKER (GEN POWER AND NORMAL POWER) TO SIGNAL LOSS/RETURN OF NORMAL POWER AND GEN POWER AVAILABLE/NOT AVAILABLE FOR POWER SEQUENCING OF THE TWO (2) BREAKERS TO AUTOMATICALLY SWITCH FROM NORMAL POWER TO GEN POWER AND BACK TO NORMAL POWER ON RESTORATION OF NORMAL POWER. THE CONTROLLER SHALL MONITOR GENERATOR STATUS (RUN/STOP/FAILURE) VIA RELAYS TO BE ADDED TO THE GENERATOR AND REPORT SIGNALS TO THE FRONT OFFICE FIRE ALARM PANEL AND DDC SYSTEM IN THE ROOM NEXT TO THE MAIN MECHANICAL/ELEC ROOM. 24VDC POWER SUPPLY SHALL BE POWERED OFF OF THE USP AND PROVIDE CONTROL AND SENSOR POWER TO THE DEVICES ADDED TO MTU TO CONVERT IT TO AN ATS. THE CONTROLLER SHALL PROVIDE START AND STOP SIGNALS TO THE GENERATOR. THE CONTROLLER SHALL RESPOND TO TWO
(2) NEW TEST SWITCHES TO BE ADDED IN THE MTU AT EACH MOTORIZED BREAKER (GEN AND NORMAL POWER) FOR BREAKER
OPERATION TESTING.
PROVIDE TWO (2) TEST SWITCHES IN THE MTU.
PROVIDE TWO (2) VOLTAGE MONITORS (PT) IN THE MTU.
PROVIDE TWO (2) CONTROL POWER TRANSFORMER (CPT) IN THE MTU.
PROVIDE ONE (1) CONTROL POWER TRANSFORMER CONTACT (CPT/TO) IN THE MTU.
REMOVE THE KIRK KEY INTERLOCK TO ALLOW THE SYSTEM TO AUTOMATICALLY TRANSFER POWER SOURCE BASED ON LOSS OF NORMAL POWER AND RETURN OF NORMAL POWER AND USE OF THE MANUAL TEST SWITCHES. PROVIDE TWO TEST SWITCHES TO SIMULATE GENERATOR TRANSFER CONDITIONS UNDER LOAD AND NOT UNDER LOAD. WIRE OPEN AND CLOSE
SIGNALS TO TEST SWITCH FOR CONTROLLER SIMULATION.
THE CABLE INPUT PANEL FOR A MOBILE GENERATOR SHALL STAY AND ADD CABLING FROM THE CONTROL PANEL FOR A ROLL- UP GENERATOR START CIRCUIT BE CONNECTED IF A ROLL-UP GENERATOR IS EVER NEEDED DUE TO THE STATIONARY
GENERATOR BEING OUT OF SERVICE.
4 5 6 7 8
ABB TEST SWITCH
ADDED
WOODWARD DTSC
200 A CONTROLLER
ADDED
1000 VA UPS FOR
STEADY STATE POWER
ADDED
24VDC POWER SUPPLY
FOR DEVICE
CONTROL POWER
ABB TEST SWITCH
ADDED
CPT - T/O CONTROL
CONTACTOR FOR CONTROLLING
BREAKER POSITIONING
PT TO MONITOR
VOLTAGE
ADDED
PT TO MONITOR
VOLTAGE
ADDED
1000 VA CPT
CONTROL POWER
TRANSFORMER
GENERATOR
LINE SIDE
UTILITY
LINE SIDE
1000 VA CPT
CONTROL POWER
TRANSFORMER
TO WOODWARD DTSC 200 A
CONTROLLER
1. RUN PARALLEL OPEN/CLOSE
COMMANDS VIA INTERPOSING
RELAYS & TEST SWITCHES.
2. BREAKER STATUS FROM
EXTRA CONTACTS.
GEN START/STOP SIGNAL
GEN STATUS SIGNALS
PARTIAL CONTROL DIAGRAM FOR ATS OPERATION CONVERSION MTU TO ATS
SCHEMATIC
C O M M O N
W E
AL
TH OF
V I
R G I N I A
P
RR
O F
E S S
I ON A L E N
G I
N E E
A
ALL RIGHTS RESERVED. THESE DRAWINGS AND SPECIFICATIONS ARE
INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF
STRATUS®. WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS
EXECUTED OR NOT. THEY ARE NOT TO BE USED IN ANY MANNER ON OTHER
PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY THE AGREEMENT
IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO STRATUS®.
REPRODUCTIONS OF SPECIFICATIONS WITHOUT THE WRITTEN CONSENT
OF STRATUS® IS PROHIBITED.
COPYRIGHT 2025 STRATUS
R
Seal
82 3 4 5 6 7
H
B
C
D
E
F
G
1 82 3 4 5 6 7
RANDALL O. SPENCER
Lic No.029321
5/ 8/
1:
:1
A
M A ut od es k
D oc s:
//2
6-
B en ja m in F ra nk lin M
S G en er at or
/2
6-
M
E P
C en tr al v
.r vt
E2.1
E L
E C
T R
IC
A
L P
A R
T
IA
L P
O W
E R
R
IS
E R
05/11/2026
B E
N J
A M
IN
F
R A
N K
L
IN
M S
W E
S T
G E
N E
R A
T O
R
P R
O J
E C
T C
O D
E
-1
SUBMISSION
2025-0087
M
ID
D
LE
S C
H O
O L
R D
R O
C K
Y M
O U
N T
V
A
F R
A N
K L
IN
C
O U
N T
Y P
U B
L
IC
S C
H O
O L
S
D E
S
IG
N E
R : R
O S
D R
A F
T E
R
S
JH
C H
E C
K E
R : R
O S
V A
LL
E
Y P
O
IN
T E
P K
W Y
, S T
E
R O
A N
O K
E , V
A
R E
V
D A
T E
N
O T
E
/0 5/
A
D D
E N
D U
M
| T-1 - TITLE SHEET |
| Sheets |
| T-1 - TITLE SHEET |
| E0.1 - ELECTRICAL DETAILS, LEGEND, AND SCHEDULES |
| Sheets |
| E0.1 - ELECTRICAL DETAILS, LEGEND, AND SCHEDULES |
| E1.1 - ELECTRICAL PARTIAL FLOOR PLAN |
| Sheets |
| E1.1 - ELECTRICAL PARTIAL FLOOR PLAN |
| E2.1 - ELECTRICAL PARTIAL POWER RISER |
| Sheets |
| E2.1 - ELECTRICAL PARTIAL POWER RISER |
| E1.1 - ELECTRICAL PARTIAL FLOOR PLAN.pdf |
| Sheets |
| E1.1 - ELECTRICAL PARTIAL FLOOR PLAN |