Attachment #6 Government Furnished Equipment Available Dated: 6 Aug 13
1. Task 1 - Space Chemistry Laboratory 1
0. Universal Guided Ion Beam Instrument (GIB) with:
0. Wien filter for monoenergetic ion or neutral beam production(1-500eV)
0. Mass Spectrometric detection
0. Electrospray source
0. Double Mass Spectrometer for optical luminescence and surface ionization studies with:
1. Optical spectrometer
1. Quadrupole mass spectrometer
0. Colloid Thruster quadrupole mass spectrometer apparatus with:
2. Rotatable electrospray stage
2. Quartz crystal microbalance
2. Faraday cup
2. Retarding potential analyser (RPA)
2. Quadrupole Mass Spectrometer
0. Reflectron Time-of-Flight mass spectrometer (TOF) with:
3. Electrospray source
3. Electron impact source
1. Task 2 - Space Chemistry Laboratory 2
1. Lasers:
0. Newport/SpectraPhysics PRO-230 YAG laser, seeded, with 2nd and 3rd harmonic generation
0. Newport/SpectraPhysics PRO-230 YAG laser, unseeded, with 2nd and 3rd harmonic generation
0. LambdaPhysik ScanMate II dye laser with frequency doubling
0. LambdaPhysik FL3002 II dye laser with frequency doubling (qty 2)
0. LaserVision Infrared OPO/OPA system
1. Instruments:
1. supersonic jet time-of-flight mass spectrometer with positive and negative ion detection capabilities
1. multistage mass spectrometer incorporating electrospray ionization, quadrupole mass selection, ion trapping at room temperature and 4K, and detection of positive or negative ions
1. Bruker Step-Scan FTIR spectrometer
1. Task 3 – HYPREP
2. US3D Navier-Stokes continuum flow solver code
2. Native DSMC code
2. Quad core Linux Xeon based stand-alone PCs
2. TecPlot visualization software
2. Gridgen grid generating software
1. Task 4 - Plasma chemistry Laboratory
3. Selected Ion Flow Tube (SIFT) with:
0. Electrospray inlet
0. Chemical Ionization
0. Laser vaporization
0. Quadrupole mass spectrometer detection
0. Metered gas flows
0. Variable temperature – 100-700K
3. Flowing Afterglow Langmuir Probe (FALP) apparatus
1. Variable temperature – 300-600K
1. Quadrupole mass spectrometer detection
1. Metered gas flows
3. High Temperature Flowing Afterglow Langmuir Probe (HTFLAP) apparatus
2. Variable temperature – 300-1800K
2. Quadrupole mass spectrometer detection
2. Metered gas flows