B08_Attachment_4_-_LOWE_335201_-_Drawings.pdf
PDF 3 MB Posted
- Solicitation number
- 140P4326R0009
About this file
Construction Documents Summary
These are 100% draft construction documents for the "Construct Security and Egress Doors at CH Mezzanine + Boott Mill #6 / Floors 3 and 5" project at Lowell National Historical Park in Lowell, Massachusetts. The project is being executed by the United States Department of the Interior, National Park Service, Denver Service Center. The contract number is 140P2021D003 with task order 140P8223F0021. The documents include architectural drawings showing site location plans, floor plans for the third and fifth floors of Boott Mill, interior elevations, and a location plan within the wider Lowell National Historical Park area. The primary architect is GWWO West (Hartford, CT) with VHB serving as prime/architect (Williamsburg, VA). Mechanical and electrical design are provided by AEI (Madison, WI).
The construction documents specify installation of security and egress doors with associated hardware, electrified locking mechanisms, access control systems, door position switches, and an integrated security infrastructure including closed-circuit television cameras, access control panels, and networking requirements. Key construction notes detail requirements for door types (single, double, and dual swing configurations), hardware specifications (panic devices, electrified strikes, electro-magnetic locking hardware), and coordination requirements with existing building systems. The documents include electrical symbols and abbreviations for security devices, cabling routing through existing IT infrastructure, and specific mounting heights and locations for access control readers, cameras, and alarm systems. The project requires coordination with National Park Services representatives for field-of-view verification and IT infrastructure integration prior to installation.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ACP
NVR
PS
DM
K
L
P
WS
D
E
M
L
D
P
E
M
S
I
I
M
V
DR
R
P
ABBREVIATIONS
REFERENCE SYMBOLS
KEYNOTE NUMBER REVISION NUMBER
CONSTRUCTION BULLETIN NUMBER
ETHERNET/FAST ETHERNET
GIGABIT ETHERNET (SHORT WAVELENGTH)
GIGABIT ETHERNET (LONG WAVELENGTH)
ABOVE CEILING/ALTERNATING CURRENT
ACCESS CONTROL PANEL
ACOUSTICAL CEILING TILE
AUTOMATIC DOOR OPENER
ABOVE FINISHED FLOOR
AUTHORITY HAVING JURISDICTION
ALTERNATE
ALARM PANEL
APPLICATION PROGRAMMING INTERFACE
ARCHITECTURAL
ABOVE SUSPENDED CEILING
ACCESS CONTROL MANAGEMENT SYSTEM
AUTOMATIC
AMERICAN WIRE GAUGE
BUILDING AUTOMATION SYSTEM
BUILDING CONTROL SYSTEM
BUILDING ENTRANCE FACILITY
BELOW FINISH CEILING
BELOW FLOOR LEVEL
BUILDING
BUILDING MANAGEMENT SYSTEM
BREAKER
CONDUIT
CIRCUIT
CIRCUIT BREAKER
CEILING
CONTRACTOR
CORRIDOR
CONSOLIDATION POINT
CABLE TRAY
DIRECT BURIAL
DIRECT CURRENT
DEDICATED
DETAIL
DIAMETER
DOWN
DISCONNECT SWITCH
DIGITAL VIDEO RECORDER
EMPTY CONDUIT/ELECTRICAL CONTRACTOR
ELECTRIC DUCT BANK
ENTRANCE FACILITY
EQUIPMENT GROUND
ENGINE GENERATOR SET
EQUIPMENT INTERMEDIATE DISTRIBUTION FACILITY
EXPANSION JOINT
ELECTRIC/ELECTRICAL
EMERGENCY
ELECTROMAGNETIC INTERFERENCE
ELECTRICAL METALLIC TUBING
END-OF-LINE RESISTOR
EQUIPMENT
EQUIPMENT ROOM
EXISTING TO REMAIN
FLUSH WITH FINISHED CEILING
FLUSH WITH FINISHED FLOOR
FLUSH WITH FINISHED WALL
FIRE ALARM
FIRE ALARM CONTROL PANEL
AT FLOOR LINE
FLEXIBLE
FLOOR
FLOW SWITCH
FUSED SAFETY SWITCH
FLAME SAFEGUARD CONTROL PANEL
FULL VOLTAGE NON-REVERSING
FOREIGN EXCHANGE OFFICE
GLOBAL AREA NETWORK
GIGABIT INTERFACE CONVERTER
GENERAL CONTRACTOR
GROUND FAULT CIRCUIT INTERRUPTER
GROUND
GENERATOR
GALVANIZED RIGID CONDUIT
GRAPHICAL USER INTERFACE
HANDHOLE
HEIGHT/HEAT TRACE
HIGH VOLTAGE
INTERMEDIATE DISTRIBUTION FACILITY
INTERMEDIATE METAL CONDUIT
INTERNET PROTOCOL
JUNCTION BOX
KNOCK-OUT
KILOVOLT
10/100BaseTX 1000BaseSX 1000BaseLX
AC
ACP
ACT
ADO
AFF
AHJ
ALT
AP
API
ARCH
ASC
ACMS
AUTO
AWG
BAS
BCS
BEF
BFC
BFL
BLDG
BMS
BRKR
C
CCT
CCT BKR
CLG
CONTR
CORR
CP
CT
DB
DC
DED
DET
DIA
DN
DS
DVR
EC
EDB
EF
EG
EGS
EIDF
EJ
ELEC
EMER
EMI
EMT
EOL
EQUIP
ER
ETR
F/FC
F/FF
F/FW
FA
FACP
FL
FLEX
FLR
FS
FSS
FSCP
FVNR
FXO
GAN
GBIC
GC
GFCI
GND
GEN
GRC
GUI
HH
HT
HV
IDF
IMC
IP
JB
KO
KV
KILOVOLT-AMPERES
KILOWATTS
KILOWATT HOURS
LOCAL AREA NETWORK
LOW VOLTAGE
MASTER ANTENNA TELEVISION
MECHANICAL CONTRACTOR
MAIN DISTRIBUTION FACILITY
MAIN EQUIPMENT ROOM
MAINTENANCE HOLE
MULTIMODE
MEGA-PIXEL
MOUNTED
MOUNTING
MOUNTING HEIGHT
NOT APPLICABLE
NEW CONNECTION/NORMALLY CLOSED
NOT IN CONTRACT
NORMALLY OPEN
NOT TO SCALE
NETWORK VIDEO RECORDER
ON CENTER
OWNER FURNISHED CONTRACTOR INSTALLED
OWNER FURNISHED OWNER INSTALLED
OPERATING SYSTEM
PULL BOX/PUSH-BUTTON
PRIVATE BRANCH EXCHANGE
PLUMBING CONTRACTOR / PHOTOCELL /
PERSONAL COMPUTER
POWER DISTRIBUTION UNIT
POWER FACTOR
PHASE
PLUMBING
PANEL
POWER
REFLECTED CEILING PLAN
RECESSED
RECEPTACLE
RELOCATE
REQUIRED
RADIO FREQUENCY
ROUGH-IN: TO BE PROVIDED WITH CAP /
COVER AND PAINTED TO MATCH SURFACE
REMOTE MODULES
RACK UNIT
SOFTWARE DEVELOPMENT KIT
SHEET
SIGNAL
SIMILAR
STANDARD INFORMATION OUTLET
SESSION INITIATION PROTOCOL
SINGLEMODE
SECURITY MANAGEMENT SYSTEM
SPECIFICATION
SAFETY SWITCH
STATION
SWITCH
TERMINAL BOX
TRANSPORT CONTROL PROTOCOL
TELEPHONE
TO FLOOR ABOVE
TO FLOOR BELOW
TELECOMMUNICATIONS OUTLET
TELECOM ROOM
TAMPER SWITCH/TIME SWITCH
TELEVISION
TRANSIENT VOLTAGE SURGE SUPPRESSION
TYPICAL
UNDER COUNTER
UNDERGROUND
UNLESS OTHERWISE NOTED
UNINTERRUPTIBLE POWER SUPPLY
UNIVERSAL SERIAL BUS
VOLTAGE
VOICE COMMUNICATION SYSTEM
VIDEO MANAGEMENT SYSTEM
VOICE OVER INTERNET PROTOCOL
WIRE
WITH
WIDE AREA NETWORK
WIRELESS LOCAL AREA NETWORK
WEATHERPROOF
WALL SURFACE
WATER TIGHT
EXIST
TRANSFORMER
EXPLOSION PROOF
KVA
KW
KWH
LAN
LV
MATV
MC
MDF
MER
MH
MM
MP
MTD
MTG
MTG HGT
NA
NC
NIC
NO
NTS
NVR
OC
OFCI
OFOI
OS
PB
PBX
PC
PDU
PF
PH
PLBG
PNL
PWR
RCP
REC
RECEP
REL
REQD
RF
R/I
RM
RU
SDK
SHT
SIG
SIM
SIO
SIP
SM
SMS
SPEC
SS
STA
SW
TB
TCP
TEL
TFA
TFB
TO
TR
TS
TV
TVSS
TYP
UC
UG
UON
UPS
USB
V
VCS
VMS
VoIP
W W/
WAN
WLAN
WP
WS
WT
X
XFMR
XP
EMERGENCY REQUEST TO EXIT DEVICE (NIC)
MOUNTING LOCATION: WALL
MOUNTING HEIGHT: AS NOTED
PANIC/DURESS BUTTON
MOUNTING LOCATION: UNDER DESKTOP
MOUNTING HEIGHT: REFER TO DETAIL
KNOX BOX (NIC)
MOUNTING LOCATION: WALL
*PROVIDE TAMPER/DRY-CONTACT CLOSURES TO ALL
RAPID-ENTRY BOXES. RAPID ENTRY ALARMS SHALL BE UNIQUELY
IDENTIFIED ON THE ACMS.
ACCESS CONTROL PANEL
CONTRACTOR TO PROVIDE CAT 6A DATA CONNECTION
NETWORK VIDEO RECORDER (NVR)
CONTRACTOR TO PROVIDE CAT 6A DATA CONNECTION
POWER SUPPLY
#DOOR TAGXXXX
ELECTRICAL SYMBOLS AND ABBREVIATIONS
POLE MOUNTED
#-## = FLOOR-SEQUENTIAL NUMBER
MULTI-IMAGER MEGA PIXEL CAMERA
TYPE:180 DEGREE
CONTRACTOR TO PROVIDE CAT 68 DATA CONNECTION.#-##
INTERCOM SUBSTATION
MOUNTING LOCATION: AS NOTED
MOUNTING HEIGHT: AS NOTED
CONTRACTOR TO PROVIDE CAT 6A DATA CONNECTION
ACCESS CONTROL READER
MOUNTING LOCATION: WALL
MOUNTING HEIGHT: REFER TO DETAIL
ELECTRIFIED LOCKING HARDWARE
MOUNTING LOCATION: DOOR
MOUNTING HEIGHT: REFER TO DETAIL SHEET
ELECTRIFIED PANIC HARDWARE
MOUNTING LOCATION: DOOR
MOUNTING HEIGHT: REFER TO DETAIL SHEET
DOOR POSITION SWITCH
MOUNTING LOCATION: REFER TO DRAWINGS/DETAIL
MOUNTING HEIGHT: REFER TO DETAIL SHEET
SECURITY WORKSTATION
MOUNTING LOCATION: DESK (UNLESS OTHERWISE NOTED)
MOUNTING HEIGHT: AS NOTED
CONTRACTOR TO PROVIDE CAT 6A DATA CONNECTION
LCD MONITOR
MOUNTING LOCATION: DESK (UNLESS OTHERWISE NOTED)
MOUNTING HEIGHT: AS NOTED
MULTI-IMAGER MEGA PIXEL CAMERA
TYPE:360 DEGREE
CONTRACTOR TO PROVIDE CAT 68 DATA CONNECTION.#-##
MOUNTING HEIGHT: REFER TO DETAIL SHEET
HIGH-SECURITY DOOR POSITION SWITCH
MOUNTING LOCATION: REFER TO DRAWINGS/DETAIL
MOUNTING HEIGHT: REFER TO DETAIL SHEET
ROLL-UP SHUTTER DOOR POSITION SWITCH
MOUNTING LOCATION: REFER TO DRAWINGS/DETAIL
MOUNTING HEIGHT: AS NOTED
CONTRACTOR TO PROVIDE CAT 6A DATA CONNECTION
MOUNTING LOCATION: REFER TO DRAWINGS/DETAIL
VIDEO INTERCOM SUBSTATION
LOCAL ALARM (NIC)
MOUNTING LOCATION: REFER TO DETAILS
MOUNTING HEIGHT: AS NOTED
DEVICE MOUNTS
DETAIL REFERENCE
TOP DESIGNATES DETAIL NUMBER
BOTTOM DESIGNATES SHEET NUMBER
DET #
SHT #
MOUNTING LOCATION: DESK
BADGE PRINTER
CAMERAS
PEDESTAL/GOOSENECK MOUNTED
MOUNTING HEIGHT: AS NOTED
CONTRACTOR TO PROVIDE CAT 6A DATA CONNECTION
MOUNTING LOCATION: CONTROLLED THROUGH ACMS
INTERCOM MASTER STATION
MOUNTING LOCATION: DESK
MOUNTING HEIGHT: REFER TO DETAIL SHEET
DOOR RELEASE BUTTON
REDIRECTOR/DEMARCATION PANEL
CONTRACTOR TO PROVIDE CAT 6A DATA CONNECTION
PARAPET MOUNTED (J-BOX)
SURFACE MOUNTED (J-BOX)
RECESS MOUNTED (J-BOX)
WIRELESS PANIC/DURESS BUTTON
MOUNTING LOCATION: UNDER DESKTOP
MOUNTING HEIGHT: REFER TO DETAIL
OTHER
HEAD-END EQUIPMENT
ACCESS CONTROL
INTRUSION SYSTEM
DOOR MONITORING
CALL INITIATION DEVICES
EMERGENCY BREAK GLASS (NIC)
MOUNTING LOCATION: WALL
MOUNTING HEIGHT: AS NOTED
MOUNTING HEIGHT: REFER TO DETAIL SHEET
ELECTRO-MAGNETIC LOCKING HARDWARE
MOUNTING LOCATION: DOOR
SIZE: REFER TO DRAWINGS
FIXED IP CAMERA
MOUNTING LOCATION: WALL
CONTRACTOR TO PROVIDE CAT 68 DATA CONNECTION.
MOUNTING HEIGHT: REFER TO DETAIL SHEET
ELECTRIFIED STRIKE
MOUNTING LOCATION: DOOR
DOOR HARDWARE
SERVER RACK (NIC)
MOUNTING LOCATION: REFER TO DETAILS
MOUNTING HEIGHT: AS NOTED
CONTRACTOR TO PROVIDE CAT 6A DATA CONNECTION
1. REFER TO DRAWINGS AND DETAIL SHEET(S) FOR MOUNTING LOCATION AND HEIGHT INFORMATION.
2. TYPICAL SYMBOLS INDICATED. ALL SYMBOLS MAY NOT BE REFLECTED ON PLAN DRAWINGS OR USED.
A
ACCESS CONTROL READER: FUTURE/TENANT DEVICE
MOUNTING: CONTRACTOR TO PROVIDE ONLY ROUGH-IN
AND CABLING TO THE LOCATION INDICATED ON SECURITY
DRAWING(S)
A F
VISITOR BADGE PRINTER
MOUNTING LOCATION: DESK
D
MOUNTING HEIGHT: REFER TO DETAIL SHEET
DELAYED EGRESS
MOUNTING LOCATION: DOOR
ENCLOSED CAMERA INDICATES
CEILING/RECESSED MOUNT TYPE
MOUNTING LOCATION: REFER TO DRAWINGS
DRY CONTACT RELAY CLOSURE
ACCESS CONTROL READER: MULLION MOUNT
MOUNTING LOCATION: DOOR FRAME
A M
MOUNTING HEIGHT: REFER TO DETAIL
T TEMPERATURE, HUMIDITY, AND WATER LEAK ENVIRONMENTAL
CONTROLLER
REQUEST-TO-EXIT PASSIVE INFRARED (PIR) MOTION SENSOR.
MOUNTING LOCATION: CEILING
360-DEGREE PANORAMIC CAMERA
TYPE: FISH-EYE
CONTRACTOR TO PROVIDE CAT 68 DATA CONNECTION.
100% DRAFT CONSTRUCTION DOCUMENTS
CONTRACT #: 140P2021D003 | TASK ORDER #: 140P8223F0021
MECHANICAL:
AEI
MADISON, WI
ELECTRICAL:
AEI
MADISON, WI
STRUCTURAL:
N/A
CIVIL:
N/A
PRIME/ARCH:
VHB
WILLIAMSBURG, VA
ARCHITECT:
GWWO WEST
HARTFORD, CT
ELECTRICAL SYMBOLS AND
ABBREVIATIONS
UTILITY
SINK
347348
363362
330329
361360
MEN
WOMEN
OFFICES
CORRIDOR
LOUVER LOUVER
MECHANICAL ROOM
MECHANICAL
GENERATORSUPPLIES
JAN CLO
I.T. CHASE
SUMMER CAMP CLOSET
HISTORY STUDIO WORKSHOP
WORKERS ON
THE LINE
WORKSHOP
STUDIO
SUPPLIES
EXHIBIT
WEAVE ROOM
WORKSHOP
WORK SINK
WORKSHOP SUPPLY CLOSET
LARGE LOOM
CREELS
TEACHERS
LOCKER
ROOM
EDUC. CENTER
DIRECTOR'S
OFFICEPARK
RANGER
SUPERVISOR
SHEILA
KIRSCHBAUM
ELLEN
ANSTEY
COPY
ROOM
CAROL
LIASSON
CAROL
MEEHAN
SETH
COOPER
MIKE
CURRAN
FRANK
CLARK
REBECCA
LOFGREN
PARK
RANGER
UML
CONTRACTORTABLES
EAST STAIR
TOWER
LOBBY
EXHIBIT/ORIENTATION
MAINTENANCE SHOP
POWER TO
PRODUCTION
WORKSHOP
RESOURCE ROOM
INVENTORS'
CORNER
WORKSHOP
EL. 50.30'
338 A F
F F
ACP
PS
D F
D F
C-03-03
C-03-04
C-03-05
100% DRAFT CONSTRUCTION DOCUMENTS
CONTRACT #: 140P2021D003 | TASK ORDER #: 140P8223F0021
MECHANICAL:
AEI
MADISON, WI
ELECTRICAL:
AEI
MADISON, WI
STRUCTURAL:
N/A
CIVIL:
N/A
PRIME/ARCH:
VHB
WILLIAMSBURG, VA
ARCHITECT:
GWWO WEST
HARTFORD, CT
BOOTT MILL - ELECTRICAL THIRD
FLOOR PLAN - AREA 2
SHEET KEYNOTES #
GENERAL NOTES
1. PENDANT DROP MOUNTED 360-DEGREE
MULTI-IMAGE CAMERA.
2. PENDANT DROP MOUNTED FISH-EYE TYPE
CAMERA.
3. CONTRACTOR TO PROVIDE INFRASTRUCTURE
ONLY FOR FUTURE CARD READER AND DOOR
POSITION SWITCHES.
4. SPARE 110v 20 AMP CIRCUIT TO BE PROVIDED
BY EXISTING ELECTRICAL PANEL.
5. ROUTE TELECOMMUNICATION CABLING FOR
SECURITY EQUIPMENT TO EXISTING I.T.
CHASE.
6. MECHANICAL REQUEST-TO-EXIT FUNCTION
TO BE PROVIDED.
7. RENOVATION PLANNED FOR EGRESS DOOR:
LOWE PROJECT REFERENCE - 335201.
1. ACCESS CONTROL PANELS TO
ACCOMMODATE AN ADDITIONAL 20%
CAPACITY FOR FUTURE DEVICES.
2. SECURITY DEDICATED NETWORK
SWITCHES TO ACCOMMODATE AN
ADDITIONAL 20% PORT CAPACITY
3. CONTRACTOR TO COORDINATE EXACT
FIELD-OF-VIEW WITH NATIONAL PARK
SERVICES REPRESENTATIVE PRIOR TO
INSTALLATION.
4. CONTRACTOR TO COORDINATE CABLING
ROUTING WITH NATIONAL PARK
SERVICES I.T. REPRESENTATIVE PRIOR
TO INSTALLATION.
551 552550549
EL. 77.03'
WOMEN
MEN
GEN/BOILER
STACKS
583A583
556555
MECH'L
FOLK FEST
SUPPLIES
JAN CLO
I.T. CHASE
WOMEN'S
LOCKERS
SUPPLIES
ELECT'L
I.T. STORAGE
I.T. SERVER
CONNIE
BOSOLD
MEN'S
LOCKERS
ELLEN
FROST
EMILY
LEVINE
MARY
PRICE
LOCKERS
COPIER
MECH'L
UNIFORMS
INTERP.
STORAGE
INTERP.
STORAGE
COSTUME CLOSET
PARK
RANGER
DAVID
BYERS
JONATHAN
PARKER
SEASONAL
FAX/PRINTER
INTERP
RANGER
INTERP
RANGER
RADIOS
MAIL/KEYS
I & E
ADMIN.KITCHEN
EAST STAIR
TOWER
LOBBYCONFERENCE ROOM B
I.T. WORK ROOM
CATHY
NEVEUX
GREG
JONES
KERRY
OLSON
(8) SEASONAL
INTERP. PARK
RANGERS
CONFERENCE ROOM A
ENVIRONMENT
LABS
(5 DOUBLE-BACK
WORK STATIONS)
EXHIBITS
AMY
GLOWACKI
CHANGE IN THE MAKING CLASSROOM
OPEN
MAP
CLASSROOM
CLOSED
MAP
CLASSROOM
CHANGE IN THE MAKING CLASSROOM
CLOSET
EL. 77.03'
P P
A
P P
A
ACP
PS
C-05-01
100% DRAFT CONSTRUCTION DOCUMENTS
CONTRACT #: 140P2021D003 | TASK ORDER #: 140P8223F0021
MECHANICAL:
AEI
MADISON, WI
ELECTRICAL:
AEI
MADISON, WI
STRUCTURAL:
N/A
CIVIL:
N/A
PRIME/ARCH:
VHB
WILLIAMSBURG, VA
ARCHITECT:
GWWO WEST
HARTFORD, CT
BOOTT MILL - ELECTRICAL FIFTH
FLOOR PLAN - AREA 2
SHEET KEYNOTES #
GENERAL NOTES
1. PENDANT DROP MOUNTED 360-DEGREE
MULTI-IMAGE CAMERA.
2. SPARE 110V 20 AMP CIRCUIT TO BE PROVIDED
BY EXISTING ELECTRICAL PANEL.
3. ROUTE TELECOMMUNICATION CABLING FOR
SECURITY EQUIPMENT TO EXISTING I.T.
CHASE.
4. RENOVATION PLANNED FOR EGRESS DOOR:
LOWE PROJECT REFERENCE NUMBER -
335201.
1. ACCESS CONTROL PANELS TO
ACCOMMODATE AN ADDITIONAL 20%
CAPACITY FOR FUTURE DEVICES.
2. SECURITY DEDICATED NETWORK
SWITCHES TO ACCOMMODATE AN
ADDITIONAL 20% PORT CAPACITY
3. CONTRACTOR TO COORDINATE EXACT
FIELD-OF-VIEW WITH NATIONAL PARK
SERVICES REPRESENTATIVE PRIOR TO
INSTALLATION.
4. CONTRACTOR TO COORDINATE CABLING
ROUTING WITH NATIONAL PARK
SERVICES I.T. REPRESENTATIVE PRIOR
TO INSTALLATION.
ACCESS HATCH AS REQUIRED FOR HARD CEILINGS. REFER
TO REFLECTED CEILING PLAN (RCP) FOR REQUIREMENTS.
CABLING BACK TO NEAREST SECURITY/TELECOM CLOSET.
REFER TO SPECIFICATIONS FOR ADDITIONAL DATA.
ACCESS HATCH AS REQUIRED FOR HARD CEILINGS. REFER
TO REFLECTED CEILING PLAN (RCP) FOR REQUIREMENTS.
CABLING BACK TO NEAREST SECURITY/TELECOM CLOSET.
REFER TO SPECIFICATIONS FOR ADDITIONAL DATA.
MIN 4"
UNSECURED SIDE
SECURED SIDE
38" AFF ℄ MAX 12"
44" AFF ℄
70" AFF ℄
MAX 4"
MIN 4"
UNSECURED SIDE
SECURED SIDE
38" AFF ℄ MAX 12"
44" AFF ℄
70" AFF ℄
MAX 4"
MIN 4"
UNSECURED SIDE
SECURED SIDE
38" AFF℄ MAX 12"
44" AFF℄
70" AFF℄
MAX 4"
100% DRAFT CONSTRUCTION DOCUMENTS
CONTRACT #: 140P2021D003 | TASK ORDER #: 140P8223F0021
MECHANICAL:
AEI
MADISON, WI
ELECTRICAL:
AEI
MADISON, WI
STRUCTURAL:
N/A
CIVIL:
N/A
PRIME/ARCH:
VHB
WILLIAMSBURG, VA
ARCHITECT:
GWWO WEST
HARTFORD, CT
SECURITY DETAILS
| LOWE 335201 100% DRAWINGS_REV 1 for Coord_2024_07_02 |
| LOWE 335201 DWG 1 OF 4 |
| LOWE 335201 DWG 2 OF 4 |
| LOWE 335201 DWG 3 OF 4 |
| LOWE 335201 DWG 4 OF 4_REVISED 2024)07_02 |
| LOWE 335201 100% DRAWINGS_REV 1 for Coord_2024_07_02 |
| 1. LOWE 314055 - 100% DRAFT CD DRAWINGS |
File details come from the government source that posted it. Updated .