B08_Attach_19_MEVE_-_317500-Morefiled_Pland_C16.pdf
PDF 1 MB Posted
- Solicitation number
- 140P2026R0020
About this file
This document is a water line plan engineering drawing for a project in Mesa Verde National Park, specifically covering stations 30+00 to 42+00 in Morefield Canyon. The plan details a new 6" composite water line installation, which involves multiple infrastructure modifications including installing a new isolation valve and bend in a vault with thrust blocks, installing a drain valve, and navigating around existing utilities such as underground water lines, telephone pedestals, electrical infrastructure, board and barbed wire fences, and a 30' - 12" CMP culvert. The drawing indicates a sensitive resource area with rare plants and shows potential construction staging areas, with construction limits carefully mapped to minimize environmental disruption. The project includes repairing/resetting existing infrastructure like cattleguards and managing the water transmission line to the Morefield 300,000 water storage tank area.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CP
-1
E
W
W
W
ES
ES
UG
T
T
EW
L
EW
L
EW
L
EW
L
EW
L
EW
L
EWL
EWL
EWL
EWL
EWL
EWL
EWL
EWL
EWL
EW
L
EW
L
EW
L
EW
L
EW
L
EW
L
EW
L
EW
L
EW
L
EW
L
EW
L
EW
L
EW
L
EW
L
INSTALL NEW ISOLATION
VALVE AND BEND IN VAULT WITH THRUST BLOCKS
AND RESTRAINED PIPE, SEE DETAIL 1/C49
STA 34+06.39
INSTALL DRAIN VALVE
& OUTLET PIPE
STA 41+03.81
T V
V
W
W
W
W
W
W
W
W
W
W
W
MATCHLINE STA 30+00
M
AT
CH
LI
NE
S
TA
2+
APPROXIMATE PARK BOUNDARY
EX. BOARD FENCE, TYPICAL
EX. BARBED WIRE FENCE, TYPICAL
EX. FINISHED WATER TRANSMISSION LINE
TO MOREFIELD 300,000
WATER STORAGE TANK AREA
INSTALL NEW 6" COMPOSITE
WATER LINE
EX. 30' - 12" CMP CULVERT
IE IN (W) = 6870.81
IE OUT (E) = BURIED BY ROCKS
EX. BOARD FENCE
EX. CATTLEGUARD REPAIR/RESET AS
NEEDED FOR WATER LINE INSTALLATION
SOIL TEST PIT
LE-OC-01
EX. UNDERGROUND TELEPHONE
EX. SEWER LINE, TYPICAL
EX. ELECTRICAL PEDESTAL
EX. UNDERGROUND TELEPHONE PEDESTAL
(DO NOT DISTURB)
EX. UNDERGROUND WATER
UTILITIES VAULT 3' X 3' ,TO BE REMOVED
AFTER NEW LINE IS IN SERVICE
EX. WATER - UTILITY LOCATE
CATHODE TEST STATION (BLUE PIPE)
EX. UNDERGROUND WATER
UTILITIES VAULT 2.5' X 2.5' ,TO BE REMOVED
AFTER NEW LINE IS IN SERVICE
APPROXIMATE PARK BOUNDARY
EX. BARBED WIRE FENCE, TYPICAL
EX. ANODE BED
L-
L-
L-
L- 13 L-14 L-15
L-16
+0
+0
+0
+0
+0
+0
34+00
35+00
36+00
37+00
38+00
39+00
40+00
41+00
42+00
43+00
44+00
WATER LINE
PLAN
STA 30+00 TO STA 42+00
MOREFIELD CANYON
C16
SCALE OF FEET
8040040 1" = 40'
SENSITIVE RESOURCE AREA (RARE PLANT)
LEGEND
MEVE PARK BOUNDARY
NEW WATER LINE ALIGNMENT
POTENTIAL CONSTRUCTION STAGING AREA
H
P
T
HYDRANT
PLUG
TEE
CONTROL POINT
W
LIMIT OF WORK FENCING
V VALVE
R REDUCER
CONSTRUCTION LIMITS
| Sheets and Views |
| C14 |
File details come from the government source that posted it. Updated .