B08_Attach_17_MEVE_-_31750_Morefield_Plan_C30_No_Arc.pdf
PDF 1 MB Posted
- Solicitation number
- 140P2026R0020
About this file
The document is a water line plan for a project located in Mesa Verde National Park, specifically covering station 114+00 to station 126+00 in Morefield Canyon. The plan details a new water line alignment with multiple technical specifications, including horizontal directional drilling (HDD) locations, installation of an isolation valve, connection points to existing pipes, and provisions for protecting sensitive resource areas with rare plants. Key elements include a horizontal directional drilling setup area, construction fence installation to protect vegetation, existing utility locates for cathode test stations, and soil test pit locations. The plan includes a detailed map with construction limits, potential staging areas, and specific infrastructure components like valves, hydrant plugs, and tees, with a scale of 1" = 40' and using geographic control points along the proposed route.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W
WEWL EWL EWL EWL
EWL
EWL EWL EWL EWL EWL
EWL EWL
INSTALL ISOLATION
VALVE
STA 123+81.80
V
BEGIN HORIZONTAL
DIRECTIONAL DRILLING
STA 123+81.80
W W W
M
AT
C H
LI
N
E
ST
A
4+
M
AT
C H
LI
N
E
ST
A
6+
INSTALL NEW 6" COMPOSITE
WATER LINE
SOIL TEST PIT
LE-HDD-09
EX. WATER - UTILITY LOCATE CATHODE
TEST STATION (BLUE PIPE)
EX. WATER - UTILITY LOCATE CATHODE
TEST STATION (BLUE PIPE)
TO BE REMOVED
SOIL TEST PIT
LE-HDD-08
EXISTING 6" PIPE
TO REMAIN - 630 LF
CONNECT TO EXISTING
STAINLESS STEEL PIPE
END HORIZONTAL DIRECTIONAL DRILLING
STA 118+50.36
CONNECT TO
EXISTING PIPE
INSTALL CONSTRUCTION FENCE
OFFSET NO MORE THAN 20'
OF PROPOSED WATERLINE TO
PROTECT SENSITIVE VEGETATION
IF SOIL DISTURBING ACTIVITIES
WILL BE OCCURRING IN HDD AREAS
HORIZONTAL DIRECTIONAL
DRILLING SETUP AREA
L-79 L-80
L-81 L-82 L-83 L-84 L-85
C-268 C-269 C-281C-259C-260
C-264 C-265
114+00 115+00 116+00 117+00 118+00
119+00 120+00 121+00 122+00 123+00 124+00
125+00 126+00
WATER LINE
PLAN
STA 114+00 TO STA 126+00
MOREFIELD CANYON
C30
SCALE OF FEET
8040040 1" = 40'
SENSITIVE RESOURCE AREA (RARE PLANT)
LEGEND
MEVE PARK BOUNDARY
NEW WATER LINE ALIGNMENT
POTENTIAL CONSTRUCTION STAGING AREA
H
P
T
HYDRANT
PLUG
TEE
CONTROL POINT
W
LIMIT OF WORK FENCING
V VALVE
R REDUCER
CONSTRUCTION LIMITS
| Sheets and Views |
| C30 |
File details come from the government source that posted it. Updated .