This document package includes mechanical drawings and specifications for a federal contract opportunity to rehabilitate the Antietam Visitor Center. Key details include ductwork, piping, and HVAC equipment for new construction and demolition work at the facility. Schematics show layouts for dedicated outdoor air units, fan coil units, unit ventilators, cabinet unit heaters, electric unit heaters, and associated ductwork, piping, controls, and accessories. Specifications include equipment schedules for dedicated outdoor air handling units and condensing units, diffusers and grilles, and electric cabinet heaters and unit heaters. The project involves the National Park Service to rehabilitate the visitor center at Antietam National Battlefield.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES
1. ALL STRUCTURAL WORK SHALL BE COORDINATED WITH ARCHITECTURAL AND
MECHANICAL DRAWINGS AND SHALL CONFORM TO THE PROJECT SPECIFICATIONS,
INCLUDING THE IBC 2018 BUILDING CODE. ALL GOVERNING STANDARDS LISTED IN
THESE NOTES SHALL BE THE EDITION REFERENCED IN THIS GOVERNING CODE.
2. CONTRACTOR SHALL PROVIDE TEMPORARY SHORING, BRACING, AND SHEETING AND
MAKE SAFE ALL FLOORS, ROOFS, WALLS, AND ADJACENT PROPERTY AS PROJECT
CONDITIONS REQUIRE. SHORING AND SHEETING SHALL BE DESIGNED BY A
REGISTERED PROFESSIONAL ENGINEER LICENSED IN THE PROJECT JURISDICTION,
HIRED BY THE CONTRACTOR WHO SHALL SUBMIT SHOP DRAWINGS AND
CALCULATIONS FOR THE OWNER'S REVIEW.
3. DIMENSIONS AND ELEVATIONS OF EXISTING CONSTRUCTION GIVEN IN STRUCTURAL
DRAWINGS ARE BASED ON INFORMATION CONTAINED IN VARIOUS ORIGINAL DESIGN
AND CONSTRUCTION DOCUMENTS PROVIDED BY THE OWNER, AND LIMITED FIELD
OBSERVATIONS AND MEASUREMENTS. THE CONTRACTOR SHALL VERIFY ALL
INFORMATION PERTAINING TO EXISTING CONDITIONS BY ACTUAL MEASUREMENT AND
OBSERVATION AT THE SITE. ALL DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND
THOSE SHOWN IN THE CONTRACT DOCUMENTS SHALL BE REPORTED TO THE CO.
FOR EVALUATION BEFORE THE AFFECTED CONSTRUCTION IS PUT IN PLACE.
4. THE CONTRACT DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY. THESE NOTES
HIGHLIGHT RATHER THAN REPLACE THE SPECIFICATIONS CONTAINED IN THE
PROJECT MANUAL.
FOUNDATIONS
1. BUILDING FOUNDATIONS SHALL BEAR ON UNDISTURBED SOIL HAVING MINIMUM
BEARING CAPACITY OF 1500 PSF (IBC LOWER-BOUND ASSUMED VALUE). ADEQUACY
OF BEARING STRATUM SHALL BE VERIFIED IN FIELD PRIOR TO PLACING CONCRETE
BY A GEOTECHNICAL CONSULTANT. ALL NECESSARY ADJUSTMENTS TO THE BOTTOM
OF FOOTINGS TO BE REVIEWED AND APPROVED BY THE STRUCTURAL ENGINEER OF
RECORD.
2. DO NOT PLACE BACKFILL AGAINST BASEMENT WALLS UNTIL ALL FLOORS BRACING
THESE ARE IN PLACE AND HAVE ATTAINED THEIR 28 DAY STRENGTH.
3. ALL EXTERIOR FOOTINGS SHALL BE PLACED A MINIMUM OF 2'-6" BELOW FINAL
GRADE.
4. CONCRETE SHALL BE POURED IN DRY EXCAVATIONS.
CONCRETE
1. ALL CONCRETE WORK SHALL CONFORM TO THE ACI FOLLOWING GOVERNING
STANDARDS.
A. AMERICAN CONCRETE INSTITUTE (ACI) "BUILDING CODE REQUIREMENTS
FOR CONCRETE" (ACI 318).
B. ACI "MANUAL OF CONCRETE PRACTICE", LATEST EDITION.
C. CONCRETE REINFORCING STEEL INSTITUTE (CRSI) "MANUAL OF
STANDARD PRACTICE", LATEST EDITION.
2. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE WITH A MINIMUM
COMPRESSIVE STRENGTH OF 4,000 PSI AT 28 DAYS, UNLESS OTHERWISE NOTED.
3. REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615,
GRADE 60. REINFORCING STEEL SHALL BE DETAILED ACCORDING TO THE ACI
"DETAILS AND DETAILING OF REINFORCEMENT" (ACI 315).
4. WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A1064, WITH A MINIMUM
YIELD STRENGTH OF 65,000 PSI.
5. COORDINATE SIZE AND LOCATION OF ALL OPENINGS AND PIPE SLEEVES WITH ALL
OTHER DISCIPLINES DRAWINGS. MINIMUM CONCRETE BETWEEN SLEEVES SHALL BE
6".
6. ALL GROUT SHALL BE NO SHRINK WITH A MINIMUM COMPRESSIVE STRENGTH OF
5000 PSI.
7. PROVIDE CLEARANCE FROM FACE OF CONCRETE TO REINFORCEMENT AS FOLLOWS:
A. SLABS: 3/4"
B. FOOTINGS: 3"
C. WALLS: 2" FOR #6 OR LARGER, 1-1/2" FOR #5 OR SMALLER
8. SHOP DRAWINGS SHALL BE SUBMITTED TO THE CO. FOR REVIEW AND APPROVAL.
NO CONCRETE WORK SHALL COMMENCE WITHOUT APPROVED SHOP DRAWINGS.
9. CLEAN AND ROUGHEN TO 1/4" AMPLITUDE ALL EXISTING CONCRETE SURFACES TO
RECEIVE NEW CONCRETE PRIOR TO PLACEMENT.
10. SEE OTHER DRAWINGS IN THIS PROJECT FOR SIZE AND LOCATIONS OF EQUIPMENT
PADS, INSERT AND EMBED ITEMS.
11. REINFORCING DOWELS, WATER STOPS, AND OTHER EMBED ITEMS SHALL BE
INSTALLED AND SECURED PRIOR TO CONCRETE PLACEMENT. "WET-SETTING" OF
EMBEDDED ITEMS IS NOT PERMITTED.
CONCRETE BLOCK
1. ALL CONCRETE BLOCK WORK SHALL CONFORM TO THE "NATIONAL CONCRETE
MASONRY ASSOCIATION TEK MANUAL FOR THE DESIGN AND CONSTRUCTION OF
CONCRETE MASONRY", LATEST EDITION AND "ACI 530-BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES".
2. CONCRETE BLOCK SHALL BE OF LIGHTWEIGHT AGGREGATE AND CONFORM TO THE
FOLLOWING STANDARDS: SOLID/HOLLOW BLOCK: ASTM C90.
3. ALL MORTAR SHALL BE ASTM C270, TYPE S.
4. ALL GROUT FOR FILLING CELLS SHALL BE ASTM C 476 WITH MINIMUM
COMPRESSIVE STRENGTH OF 2000 PSI BUT NOT LESS THAN THE COMPRESSIVE
STRENGTH OF THE MASONRY ASSEMBLY, F'm. WHERE GROUT CELLS DO NOT
EXCEED 4" IN DIAMETER FINE GROUT SHALL BE USED.
5. ALL BLOCK DIMENSIONS INDICATED ON STRUCTURAL PLANS ARE NOMINAL
DIMENSIONS.
6. ALL CONCRETE BLOCK BELOW GRADE SHALL BE FILLED SOLID WITH GROUT.
7. CONCRETE BLOCK BELOW BEAM OR TRUSS BEARING POINTS SHALL BE FILLED
SOLID FOR A MINIMUM OF TWO COURSES IN DEPTH AND A MINIMUM OF 32" IN
WIDTH, UNLESS NOTED OTHERWISE.
8. INSTALL STANDARD WEIGHT LADDER JOINT REINFORCEMENT AT 16" ON CENTER
(SPACED VERTICALLY).
9. UNLESS NOTED OTHERWISE ALL MASONRY WALLS SHALL BE REINFORCED WITH #4@
48" ON CENTER VERTICAL. GROUT ALL REINFORCED CELLS SOLID. PROVIDE
DOWELS TO MATCH VERTICAL REINFORCING AT FOUNDATION.
NET AREA COMPRESSIVE STRENGTH OF
CONCRETE MASONRY UNIT (PSI)
NET AREA COMPRESSIVE STRENGTH OF MASONRY
ASSEMBLY, F'm (PSI) USING TYPE S MORTAR
1900 1500
STRUCTURAL STEEL
1. ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE FOLLOWING GOVERNING
STANDARDS:
A. AISC 360 "SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS".
B. AISC 303 "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND
BRIDGES".
C. AMERICAN WELDING SOCIETY (AWS D1.1) "STRUCTURAL WELDING
CODE - STEEL".
D. RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS (RCSC)
“SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH-STRENGTH
BOLTS”.
2. ALL STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING ASTM SPECIFICATIONS:
A. WIDE FLANGE SECTIONS: ASTM A992.
B. HOLLOW STRUCTURAL SECTIONS: ASTM A500, GRADE C.
C. CHANNELS, ANGLES, AND PLATES: ASTM A36.
D. BOLTED CONNECTIONS SHALL BE PER ASTM F3125. GRADES A325,
F1852, A490 OR F2280 BOLTS.
E. ANCHOR RODS: ASTM F1554, GRADE 36.
3. STEEL CONNECTION SHALL BE STANDARD AISC FRAMED BEAM CONNECTIONS, AND
SHALL BE SELECTED OR COMPLETED BY AN EXPERIENCED STEEL DETAILER UTILIZING
ASD OR LRFD LOADS AND PROCEDURES.
A. UNLESS OTHERWISE NOTED ON PLAN, PROVIDE CONNECTIONS BASED ON
MINIMUM SHEAR CAPACITY REQUIREMENTS IN THE FOLLOWING TABLE.
4. LINTELS SHALL BE INSTALLED OVER ALL OPENINGS IN MASONRY WALLS AS FOLLOWS:
POST-INSTALLED ADHESIVE AND MECHANICAL ANCHORS
1. POST INSTALLED ANCHORAGE SHALL BE INSTALLED BY QUALIFIED PERSONNEL PER
THE MANUFACTURER’S PRINTED INSTALLATION INSTRUCTIONS (MPII), AS INCLUDED
IN THE ANCHOR PACKAGING, TO INTACT BASE MATERIAL. INSTALLATION OF
ANCHORS SHALL BE CARRIED OUT BY AN INSTALLER TRAINED TO INSTALL THE
SPECIFIED ANCHORS. NOTIFY ENGINEER OF RECORD PRIOR TO INSTALLATION IF
BASE MATERIAL CONDITION DEVIATES FROM STRUCTURAL DRAWINGS OR
ASSUMPTIONS AND CONDITIONS OF THE MPII. ALL HOLES SHALL BE DRY AND
HAMMER DRILLED UNLESS OTHERWISE NOTED, AND ALL CONCRETE BASE MATERIAL
TO RECEIVE ADHESIVE ANCHORS SHALL HAVE A MINIMUM AGE OF 21 DAYS.
2. INSTALLATION OF ADHESIVE ANCHORS IN A HORIZONTAL OR UPWARDLY INCLINED
ORIENTATION AND SUPPORTING A SUSTAINED TENSION LOAD SHALL BE PERFORMED
BY A CERTIFIED ADHESIVE ANCHOR INSTALLER. CERTIFICATION SHALL INCLUDE
WRITTEN AND PERFORMANCE TESTS IN ACCORDANCE WITH THE ACI/CRSI ADHESIVE
ANCHOR INSTALLER CERTIFICATION PROGRAM OR APPROVED EQUAL. PRIOR TO THE
COMMENCEMENT OF INSTALLING ANCHORS PROVIDE OWNER AND ENGINEER OF
RECORD WITH DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR’S
PERSONNEL WHO INSTALL HORIZONTAL OR UPWARDLY INCLINED ADHESIVE ANCHORS
SUPPORTING SUSTAINED TENSION LOADS ARE TRAINED AND CERTIFIED.
A. OVERHEAD ADHESIVE ANCHORS MUST BE INSTALLED USING THE
PISTON PLUG SYSTEM SPECIFIED BY THE MPII AND PRODUCED BY
THE CORRESPONDING MANUFACTURER FOR THE ANCHOR SYSTEM
BEING INSTALLED.
3. EXISTING REINFORCING BARS IN THE STRUCTURE MAY CONFLICT WITH SPECIFIC
ANCHOR LOCATIONS. REINFORCING BARS SHALL NOT BE CUT WITHOUT THE
WRITTEN APPROVAL OF THE ENGINEER OF RECORD. UNLESS NOTED ON THE
DRAWINGS THAT THE EXISTING REBARS CAN BE CUT, THE CONTRACTOR SHALL
REVIEW THE EXISTING STRUCTURAL DRAWINGS AND SHALL UNDERTAKE TO LOCATE
THE POSITION OF THE REINFORCING BARS BY A MEANS APPROVED BY THE
ENGINEER OF RECORD.
4. ANCHOR CAPACITY IS DEPENDENT UPON SPACING BETWEEN ADJACENT ANCHORS,
PROXIMITY OF ANCHORS TO EDGE OF CONCRETE, AND EMBEDMENT DEPTH INTO
THE SUBSTRATE. INSTALL ANCHORS IN ACCORDANCE WITH SPACING, EDGE
CLEARANCES, AND EMBEDMENT DEPTHS INDICATED ON THE DRAWINGS.
FRAMING LUMBER
1. ALL FRAMING LUMBER WORK SHALL CONFORM TO THE FOLLOWING GOVERNING STANDARDS:
A. AMERICAN WOOD COUNCIL "WOOD FRAME CONSTRUCTION MANUAL FOR ONE-
AND TWO-FAMILY DWELLINGS"
B. AMERICAN WOOD COUNCIL "NATIONAL DESIGN SPECIFICATION FOR WOOD
CONSTRUCTION","NDS SUPPLEMENT: DESIGN VALUES FOR WOOD
CONSTRUCTION", AND "SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC".
2. FRAMING LUMBER SHALL HAVE EACH PIECE GRADE STAMPED, SHALL BE SURFACED DRY
(EXCEPT STUDS, WHICH SHALL BE KILN DRIED) AND SHALL CONFORM TO THE FOLLOWING
SPECIES AND GRADE:
A. RAFTERS: DOUGLAS FIR-LARCH #2, SPRUCE PINE FIR #2, OR HEM FIR #2
B. BEAMS AND HEADERS: DOUGLAS FIR-LARCH #1, SPRUCE PINE FIR #1, OR
HEM FIR #1
C. STUDS AND PLATES: DOUGLAS FIR-LARCH STUD GRADE, SPRUCE PINE FIR
STUD GRADE, OR HEM FIR STUD GRADE.
3. PRESERVATIVE-TREATED WOOD: PROVIDE TREATED LUMBER COMPLYING WITH ACQ-D
(CARBONATE). COPPER AZOLE (CA-B), OR SODIUM BORATE (SBX (DOT) WITH NaS10/2)
AT ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY, OR AS OTHERWISE INDICATED
ON ARCHITECTURAL OR STRUCTURAL DRAWINGS. ACZA TREATMENT IS NOT PERMITTED.
TREATED LUMBER AND/OR PLYWOOD SHALL BEAR THE LABEL OF AN ACCREDITED AGENCY
SHOWING 0.40 PCF RETENTION. WHERE LUMBER AND/OR PLYWOOD IS CUT OR DRILLED
AFTER TREATMENT, THE TREATED SURFACE SHALL BE FIELD-TREATED WITH COPPER
NAPTHENATE (THE CONCENTRATION OF WHICH SHALL CONTAIN A MINIMUM OF 2% COPPER
METAL) BY REPEATED BRUSHING, DIPPING, OR SOAKING UNTIL THE WOOD ABSORBS NO
MORE PRESERVATIVE. REFER TO NOTES 2 AND 3 FOR SPECIES AND GRADE OF TIMBER,
UNLESS OTHERWISE NOTED ON PLAN.
4. ALL WOOD FRAMING INCLUDING DETAILS FOR BRIDGING, BLOCKING, FIRE STOPPING, ETC., SHALL CONFORM TO THE "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION"
AND ITS SUPPLEMENTS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE NFPA
"MANUAL FOR HOUSE FRAMING" OR THE GOVERNING LOCAL/STATE BUILDING CODE.
5. FASTENING SHALL BE IN ACCORDANCE WITH THE MOST RESTRICTIVE OF: THE GOVERNING
LOCAL/STATE BUILDING CODE, OR THE MANUFACTURER'S RECOMMENDED FASTENING
SCHEDULES.
6. ALL FLUSH FRAMED CONNECTIONS SHALL BE MADE WITH APPROVED GALVANIZED STEEL
JOIST OR BEAM HANGERS, MINIMUM 18 GAUGE, INSTALLED ACCORDING TO
MANUFACTURER'S RECOMMENDATIONS.
7. WHERE FRAMING LUMBER IS FLUSH FRAMED TO STEEL, SET THESE GIRDERS 1/2" CLEAR
(MIN.) BELOW TOP OF FRAMING LUMBER, TO ALLOW FOR SHRINKAGE.
8. STUD BEARING WALLS ARE TO BE 2x4 @ 16" ON CENTER AT THE INTERIOR AND 2x6 @
16" ON CENTER AT THE EXTERIOR, UNLESS NOTED OTHERWISE ON PLAN.
9. ALL RAFTERS AND JOISTS SHALL ALIGN DIRECTLY WITH STUDS BELOW. WHERE REQUIRED,
INSTALL ADDITIONAL STUDS.
10. LAP ALL PLATES AT CORNERS AND AT INTERSECTION OF PARTITIONS.
11. STAGGER ALL TOP AND BOTTOM PLATE SPLICES A MINIMUM OF 32 INCHES.
12. USE DOUBLE STUDS @ ENDS OF WALL AND ENDS OF WALL OPENINGS.
13. AT THE ENDS OF ALL BEAMS AND HEADERS PROVIDE A BUILT UP OR SOLID POST WHOSE
WIDTH IS AT LEAST EQUAL TO THE WIDTH OF THE MEMBER IT IS SUPPORTING AND WHOSE
DEPTH IS 4" (NOMINAL) AT INTERIOR WALLS AND 6" (NOMINAL) AT EXTERIOR WALLS,
UNLESS OTHERWISE NOTED.
14. PROVIDE CROSS BRIDGING AT A MAXIMUM OF 8'-0" ON CENTER.
15. BUILT UP BEAMS LESS THAN 8" DEEP SHALL BE SPIKED TOGETHER WITH (2) 16d NAILS
@16" ON CENTER. BUILT UP BEAMS GREATER THAN 8" DEEP SHALL BE SPIKED TOGETHER
WITH (3) 16d NAILS @16" ON CENTER.
16. NO NEW OR EXISTING JOISTS SHALL BE CUT OR NOTCHED WITHOUT APPROVAL.
17. ALL LIGHT-GAUGE HANGERS SUPPORTING PRESERVATIVE TREATED WOOD SHALL MEET OR
EXCEED G185 (1.85 OZ OF ZINC PER SQUARE FOOT). ALTERNATIVELY, STAINLESS STEEL
CONNECTIONS MAY BE USED. FASTENERS SHALL MATCH THE HANGER FINISH AND
MATERIAL.
18. WHERE JOIST ORIENTATION IS PARALLEL TO EXTERIOR STUD OR FOUNDATION WALLS,
PROVIDE FULL-SECTION BLOCKING FOR 3 BAYS @ 4'-0" ON CENTER MAXIMUM WHERE
SHEATHING IS NOT CONTINUOUSLY FASTENED TO TOP OR BOTTOM OF JOIST. PROVIDE 18
GA x 1-1/2" x 1'-0" (MINIMUM) FLAT TENSION STRAP BETWEEN ALIGNED BLOCKING
MEMBERS.
19. ALL SILL PLATES SHALL BE PRESSURE TREATED AND ANCHORED TO FOUNDATION WALLS
WITH 1/2" DIAMETER HEADED ANCHOR BOLTS (ASTM F1554) @ 4'-0" ON CENTER AND
WITHIN 12" OF ALL SILL PLATES SPLICES. (MINIMUM 7" EMBED.)
MINIMUM SHEAR CAPACITY REQUIREMENTS
BEAM
DEPTH
(NOMINAL)
8", 10"
12", 14"
5. MINIMUM WELD SIZE IS 1/4" FILLET UNLESS NOTED OTHERWISE.
6. ALL BEAMS EXCEPT CANTILEVER BEAMS SHALL BE FABRICATED AND INSTALLED WITH
NATURAL CAMBER UP. CANTILEVER BEAMS SHALL BE FABRICATED AND INSTALLED
SO THAT NATURAL CAMBER RAISES CANTILEVER END.
7. FIELD CUTTING OR BURNING OF STEEL IS PROHIBITED EXCEPT WITH THE EXPRESS
WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER OF RECORD. (IN WHICH CASE
ALL BURNING OF STEEL MUST CONFORM TO THE THERMAL CUTTING REQUIREMENTS
OF AISC AND AWS)
8. WELDING SHALL BE PERFORMED BY CERTIFIED, AWS-QUALIFIED WELDERS. WELDING
ELECTRODES FOR CARBON STEEL SHALL BE AWS 5.1, CLASS E70XX.
9. SHOP PAINT INTERIOR STEEL MEMBERS, STEEL MEMBERS NOT SPRAY FIREPROOFED
WITH TNEMEC #10-99 "OR APPROVED EQUAL EXCEPT FOR MEMBERS TO BE HOT
DIPPED GALVANIZED.
10. ALL EXTERIOR MEMBERS TO BE HOT-DIPPED GALVANIZED.
11. SHOP AND ERECTION DRAWINGS SHALL BE SUBMITTED TO THE CO. FOR REVIEW
AND APPROVAL. NO FABRICATION OF STEEL SHALL COMMENCE WITHOUT APPROVED
SHOP DRAWINGS.
12. PROVIDE MECHANICALLY GALVANIZED BOLTS FOR EXTERIOR APPLICATIONS.
MIN. SHEAR
CAPACITY ASD
(Kips)
MIN. SHEAR
CAPACITY LRFD
(Kips)
16 24
28 42
UNDERPINNING NOTES:
1. THE UNDERPINNING DETAILS SHOWN HEREWITH ARE A GENERAL
GUIDELINE FOR THE CONTRACTOR. THE CONTRACTOR SHALL RETAIN A
LICENSED PROFESSIONAL ENGINEER TO DESIGN AND DETAIL THE
REQUIRED UNDERPINNING, SHEETING AND SHORING SPECIFIC TO THE
EXISTING FIELD CONDITIONS. THE CONTRACTOR IS RESPONSIBLE TO
SUBMIT SIGNED AND SEALED DRAWINGS AND CALCULATIONS TO THE
CO. FOR REVIEW. THE DRAWINGS SHALL INCORPORATE ALL FIELD DATA,
DIMENSIONS, MATERIALS, CONSTRUCTION SEQUENCING AND MEANS AND
METHODS TO BE USED SPECIFIC TO THE EXISTING CONDITIONS.
2. ALL FOUNDATIONS AND EARTHWORK OPERATIONS SHALL BE PERFORMED
IN ACCORDANCE WITH THE REQUIREMENTS OF THE IBC BUILDING
CODE.
3. ALL UNDERPINNING OPERATIONS ARE SUBJECT TO CONTROLLED
INSPECTION.
4. THE CONTRACTOR AND/OR SUB-CONTRACTOR(S) SHALL HAVE
COMPLETED NO LESS THAN FIVE (5) UNDERPINNING PROJECTS OF A
COMPARABLE SIZE AND TYPE TO THIS PROJECT, AND MUST HAVE AT
LEAST FIVE (5) YEARS EXPERIENCE IN THE WORK AND/OR APPLICABLE
TRADE. SUBMIT EVIDENCE OF SUCH EXPERIENCE FOR REVIEW.
5. THE UNDERPINNING FOUNDATIONS SHALL BEAR ON SUBGRADE HAVING A
BEARING CAPACITY EQUAL TO OR GREATER THAN THE SUBGRADE OF
THE EXISTING FOUNDATION. THE SUBGRADE AT THE LEVEL OF THE
EXISTING FOUNDATION SHALL BE INSPECTED BY A LICENSED
PROFESSIONAL ENGINEER RETAINED BY THE CONTRACTOR TO VERIFY
THE BEARING CAPACITY.
6. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE WITH A MINIMUM
ULTIMATE COMPRESSIVE STRENGTH OF 4,000 PSI AT 28 DAYS.
7. ALL GROUT SHALL BE NONSHRINK WITH A MINIMUM COMPRESSIVE
STRENGTH OF 5,000 PSI.
8. ALL DRYPACK SHALL BE A MIXTURE OF 1 PART CEMENT AND 2 PARTS
DAMP SAND, WITH 0" SLUMP.
9. ALL UNDERPINNING SHEETING AND BRACING TO REMAIN SHALL BE
PRESSURE TREATED LUMBER AND/OR OTHER APPROVED MATERIAL.
10. EXCAVATION BELOW THE WATER TABLE SHOULD BE AVOIDED, IF
POSSIBLE.
11. IF WATER IS ENCOUNTERED IN THE PIT, PROVIDE A WELL POINT NEAR
THE PIT. THE CONTRACTOR'S LICENSED PROFESSIONAL ENGINEER
SHALL DETERMINE THE LOCATION OF THE WELL POINT AND THE
METHOD OF REMOVING WATER FROM THE PIT.
12. ALL SIDES OR SLOPES OF EXCAVATIONS OR EMBANKMENTS SHALL BE
INSPECTED AFTER RAINSTORMS.
13. THE UNDERPINNING SHALL BE INSTALLED IN A MANNER SUCH THAT THE
EXPOSED FACE OF THE CONCRETE IS VERTICAL (OR AS OTHERWISE
SPECIFIED), CLEAN AND NEAT.
14. THE DEPTH OF THE UNDERPINNING PITS SHALL BE A MAXIMUM OF ONE
LIFT. THE LIFT SHALL BE WITHOUT INTERMEDIATE HORIZONTAL
CONSTRUCTION JOINTS (COLD JOINTS). MULTIPLE (VERTICAL) LEVELS
OF UNDERPINNING SHALL NOT BE PERMITTED.
WOOD STRUCTURAL PANEL SHEATHING
1. PROVIDE STRUCTURAL I PLYWOOD SHEATHING WITH BOND CLASSIFICATIONS
APPROPRIATE TO THE END USE: "EXTERIOR" (PERMANENT EXPOSURE), OR
"EXPOSURE I" (CONSTRUCTION EXPOSURE ONLY)
2. ROOF SHEATHING: NOM. 3/4" THICK T&G PLYWOOD (48/24 SPAN RATING).
3. WALL SHEATHING: NOM. 3/4" THICK PLYWOOD (48/24 SPAN RATING).
4. USE PLY CLIPS OR OTHER EDGE SUPPORT AS REQUIRED FOR PLYWOOD
SHEATHING.
5. LEAVE 1/16" SPACE AT ALL PLYWOOD PANEL END JOINTS AND 1/8"
SPACE AT ALL PANEL EDGE JOINTS.
6. UNLESS NOTED OTHERWISE, WALL SHEATHING SHALL BE FASTENED TO
FRAMING WITH 8d COMMON NAILS @ 4" ON CENTER AT EACH SHEET PERIMETER AND 12" ON CENTER ELSEWHERE. PROVIDE 2x6 BLOCKING AT
ALL FREE EDGES.
7. UNLESS NOTED OTHERWISE, ROOF SHEATHING SHALL BE FASTENED TO
FRAMING WITH 8d COMMON NAILS @ 6" ON CENTER AT EACH SHEET
PERIMETER AND 12" ON CENTER ELSEWHERE.
POST-INSTALLED ADHESIVE AND MECHANICAL ANCHORS (CONT.)
5. UNLESS OTHERWISE INDICATED, POST INSTALLED ANCHORAGE SHALL
BE ADHESIVE TYPE HILTI HIT-HY 200-R INTO CONCRETE OR HILTI
HIT-HY270 INTO BRICK MASONRY, GROUT FILLED CMU OR UNGROUTED
CMU BASE MATERIAL. PROVIDE MESH SCREEN IN UNGROUTED CMU,
UNREINFORCED MASONRY CONSTRUCTION, AND BRICK MASONRY WITH
HOLES OR VOIDS.
6. SUBSTITUTION REQUESTS FOR ALTERNATE ANCHORAGE PRODUCTS
SHALL BE SUBMITTED TO ENGINEER OF RECORD FOR REVIEW AND
APPROVAL PRIOR TO USE. THIS SHALL INCLUDE MANUFACTURER
PRODUCT DATA AND CALCULATIONS DEMONSTRATING THAT THE
PROPOSED SUBSTITUTE CAN ACHIEVE THE PERFORMANCE VALUES OF
THE SPECIFIED PRODUCT. ANCHOR CAPACITY USED IN DESIGN SHALL
BE BASED ON THE TECHNICAL DATA PUBLISHED BY THE
MANUFACTURER OR SUCH OTHER METHOD AS APPROVED BY THE
ENGINEER OF RECORD. SUBSTITUTIONS WILL BE EVALUATED BY THEIR
HAVING AN ICC-ES EVALUATION REPORT SHOWING COMPLIANCE WITH
THE RELEVANT BUILDING CODE, SEISMIC USE, LOAD RESISTANCE,
INSTALLATION CATEGORY, AND AVAILABILITY OF MPII. ADHESIVE ANCHOR
EVALUATION WILL ALSO CONSIDER CREEP, IN-SERVICE TEMPERATURE
AND INSTALLATION TEMPERATURE AND MUST PROVIDE INFORMATION ON
THESE ITEMS. SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS
MUST BE APPROVED IN WRITING BY THE ENGINEER OF RECORD PRIOR
TO USE.
MASONRY LINTELS LINTEL
4'-0" OR LESS L4x3-1/2x5/16 LLV
4'-1" to 7'-0" L6x3-1/2x5/16 LLV
A. 3-1/2" LEGS ARE HORIZONTAL.
B. PROVIDE ONE ANGLE FOR EACH 4" OF WALL THICKNESS.
C. PROVIDE L5x5x5/16 ANGLES FOR 6" THICK WALLS AND PARTITIONS WITH
OPENINGS UP TO 6'-0".
D. PROVIDE MINIMUM 6" BEARING AT EACH END.
E. LINTELS OVER 6'-4", PER IBC 2012 AND LATER, SHALL BE FIREPROOFED.
STRUCTURAL STEEL JOIST
1. ALL STEEL JOISTS SHALL BE DESIGNED, FABRICATED, AND ERECTED IN ACCORDANCE WITH
THE REQUIREMENTS OF THE OF STEEL JOIST INSTITUTE (SJI) STANDARD SPECIFICATIONS,
LOAD TABLES, AND WEIGHT TABLES FOR STEEL JOISTS AND JOIST GIRDERS.
2. THE STEEL JOIST MANUFACTURER SHALL BE A MEMBER OF SJI OR PROVIDE CERTIFICATION
THAT THE DESIGN OF ALL JOIST AND COMPONENTS CONFORM TO SJI STANDARDS.
3. MAINTAIN UNIFORM JOIST DEPTH IN AREAS WHERE JOISTS ARE EXPOSED TO VIEW.
4. CONTRACTOR'S ENGINEER IS RESPONSIBLE FOR THE DESIGN OF JOIST THAT ARE NOT
LISTED IN THE SJI STANDARD LOAD-SPAN TABLES (STANDARD JOIST), INCLUDING SPECIAL
JOIST. SUBMIT CALCULATIONS BEARING THE SEAL AND SIGNATURE OF AN ENGINEER
LICENSED IN THE PROJECT’S JURISDICTION FOR NON-STANDARD JOISTS AND COMPONENTS
REQUIRING DESIGN.
5. VERIFY THE SIZE AND LOCATION OF FLOOR OPENINGS PRIOR TO DETAILING OF JOIST AND
COMPONENTS.
6. VERIFY THE SIZE AND LOCATION OF FLOOR OPENINGS AND MEP DUCTS/PIPING PRIOR TO
DETAILING OF JOISTS AND COMPONENTS.
7. CONCENTRATED LOADS APPLIED TO JOISTS SHALL ADHERE TO THE FOLLOWING
REQUIREMENTS:
A. WHERE POSSIBLE, SUPPORT CONCENTRATED LOADS AT PANEL POINTS.
B. AT ALL CONCENTRATED LOADS NOT AT PANEL POINTS, EXCEPT AS NOTED
BELOW, EITHER PROVIDE A "STRUT" TO TRANSFER LOAD TO A PANEL POINT
ON OPPOSITE CHORD OR DESIGN CHORD SPECIFICALLY FOR LOADS.
C. "STRUTS" SHALL NOT BE REQUIRED IF THE SUM OF THE CONCENTRATED
LOADS WITHIN A CHORD PANEL DOES NOT EXCEED 100 LBS AND THE
ATTACHMENTS ARE CONCENTRIC TO THE CHORD.
8. JOIST BRIDGING SHALL BE FURNISHED AND INSTALLED TO MEET THE DESIGN AND SPACING
REQUIREMENTS OF THE SJI STANDARDS SPECIFICATIONS FOR JOIST AND JOIST GIRDERS.
COORDINATE BRIDGING WITH ARCHITECTURAL LAYOUT. WELD OR BOLT BRIDGING AND
ANCHOR AT STRUCTURAL WALLS OR BEAMS PRIOR TO THE APPLICATION OF ADDED LOADS
OTHER THAN ROOF DECK.
9. SHOP PAINT ALL STEEL JOISTS NOT SPRAY FIREPROOFED WITH TNEMEC #10-99 OR
APPROVED EQUAL (EXCEPT FOR MEMBERS TO BE HOT-DIP GALVANIZED).
10. HOT-DIP GALVANIZING SHALL CONFORM TO ASTM A123. REPAIR SCRATCHES OR ABRADED
GALVANIZED SURFACE WITH ZINC RICH PAINT. ALL EXTERIOR EXPOSED STEEL AND STEEL
SUPPORTING EXTERIOR SHALL BE HOT-DIP GALVANIZED.
11. WELD OR BOLT ALL JOISTS TO SUPPORTING STRUCTURAL STEEL MEMBERS AS SHOWN ON
DRAWINGS BUT NO LESS THAN SJI AND AWS D1.1 MINIMUMS.
12. END BEARING SEAT DEPTH SHALL BE (U.N.O.): K-SERIES: 2 1/2" DEEP.
SUB SHEET NO. TITLE OF SHEET
OF
DATE:
TECH. REVIEW:
DESIGNED: DRAWING NO.
PMIS/PKG NO.
SHEET
142608
REHABILITATE ANTIETAM VISITOR CENTER
ANTIETAM NATIONAL BATTLEFIELD, MARYLAND
ANTI 225963
05/22/2020 195
GENERAL STRUCTURAL
NOTES
S1
GM
AN
NH
STANDARD ABBREVIATIONS
ACT. ACTUAL
ADD'L ADDITIONAL
ADJ. ADJACENT
A/E DESIGN TEAM OF RECORD
ALT. ALTERNATE
ANCH. ANCHOR
APPROX. APPROXIMATE/APPROXIMATELY
ARCH. ARCHITECT/ARCHITECTURAL
BLDG. BUILDING
BM. BEAM
B.O. BOTTOM OF
BOT. BOTTOM
BRG. BEARING
BSMT. BASEMENT
CANT. CANTILEVER
C.I.P. CAST IN PLACE
C.J. CONTRACTION JOINT
CLG. CEILING
CLR. CLEAR
CMU CONCRETE MASONRY UNIT
COL. COLUMN
COMP. COMPOSITE
CONC. CONCRETE
CONST. CONSTRUCTION
CONT. CONTINUOUS
COORD. COORDINATE/COORDINATION
CONTR. CONTRACTOR
COTR. CONTRACT OFFICER'S
TECHNICAL REPRESENTATIVE
CTR. CENTER
DBL. DOUBLE
DEMO DEMOLITION/DEMOLISH
DIA. DIAMETER
DIAG. DIAGONAL
DIM. DIMENSION
D.L. DEAD LOAD
DN. DOWN
DTL. DETAIL
DWG(S) DRAWING(S)
DWL. DOWEL
(E) EXISTING MEMBER OR
DIMENSION
EA. EACH
E.F. EACH FACE
E.J. EXPANSION JOINT
EL. ELEVATION
ELEC. ELECTRICAL
ELEV. ELEVATOR
EMBED. EMBEDMENT
E.O. EDGE OF
ENGR. ENGINEER
E.O.R. ENGINEER OF RECORD
EQ. EQUAL
E.S. EACH SIDE
E.W. EACH WAY
EXIST. EXISTING
EXP. EXPANSION
EXT. EXTERIOR
FDN. FOUNDATION
FIN. FINISH
FLR. FLOOR
FRMG. FRAMING
F.S. FAR SIDE
FT. FEET
FTG. FOOTING
GA. GAGE
GALV. GALVANIZED
HDR. HEADER
HGR. HANGER
HORIZ. HORIZONTAL
H.P. HIGH POINT
HT. HEIGHT
HVAC HEATING, VENTILATION, &
AIR CONDITIONING
I.D. INSIDE DIAMETER
I.F. INSIDE FACE
I.J. ISOLATION JOINT
INFO INFORMATION
INT. INTERIOR
JT. JOINT
K KIP
LB. POUND
L.L. LIVE LOAD
LLBB LONG LEGS BACK-TO-BACK
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
L.P. LOW POINT
L.W. LIGHTWEIGHT
L.W. LONG WAY
MAX. MAXIMUM
MECH. MECHANICAL
MEP MECH., ELECT., PLUMBING, & FIRE PROTECTION
MFR. MANUFACTURER
MIN. MINIMUM
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
N.F. NEAR FACE
N.I.C. NOT IN CONTRACT
NO. NUMBER
NOM. NOMINAL
N.S. NEAR SIDE
N.T.S. NOT TO SCALE
N.W. NORMAL WEIGHT
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.F. OUTSIDE FACE
OPNG. OPENING
OPP. OPPOSITE
PC. PIECE
PERP. PERPENDICULAR
PL. PLATE
PLF POUNDS PER LINEAR FOOT
PREFAB. PREFABRICATED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
P.T. PRESERVATIVE TREATED
REINF. REINFORCE(D)/REINFORCEMENT
REQ'D REQUIRED
REV. REVISION
SCHED. SCHEDULE
SECT. SECTION
SIM. SIMILAR
S.O.G. SLAB ON GRADE
SPEC. SPECIFICATION
SQ. SQUARE
S.S. STAINLESS STEEL
STD. STANDARD
STIFF. STIFFENER
STL. STEEL
S.W. SHORT WAY
SYM. SYMMETRIC
T & B TOP & BOTTOM.
T&G TONGUE & GROOVE
TEMP. TEMPORARY/TEMPERATURE
THK. THICK(NESS)
T.O. TOP OF
TYP. TYPICAL
U-P UNDERPINNING
U.N.O. UNLESS NOTED OTHERWISE
VERT. VERTICAL
V.I.F. VERIFY IN FIELD
W/ WITH
W.P WORK POINT
W.W.R. WELDED WIRE REINFORCEMENT
# NUMBER/SIZE
Ø DIAMETER
SPECIAL INSPECTIONS (IBC)
1. INSPECTIONS SHALL BE PERFORMED BY A TESTING AGENCY PROVIDED BY
THE CONTRACTOR FOR THE ITEMS LISTED IN THE NPS SSTSI.
2. STRUCTURAL OBSERVATIONS REQUIRED BY IBC 1704.5 SHALL BE
PERFORMED BY A REGISTERED DESIGN PROFESSIONAL PROVIDED BY THE
CONTRACTOR. STRUCTURAL OBSERVATIONS SHALL BE THE VISUAL
OBSERVATION OF THE STRUCTURAL SYSTEM FOR GENERAL CONFORMANCE TO
THE APPROVED CONSTRUCTION DOCUMENTS.
CONCRETE FOOTING, GRADE
BEAM OR PILE CAP
LEGEND
WP
CONCRETE MASONRY (CMU)
CONCRETE WALL
STEEL BEAM
LEDGER ANGLE (SEE DETAIL)
SHEAR CONNECTION
WALL PLATE CONNECTION
(SEE TYP. DETAIL)
BP BEAM POCKET IN MASONRY
(SEE SEE TYP. DETAIL)
BOTTOM OF FOOTING ELEVATION
RELATIVE TO DATUM
TOP OF FRAMING ELEVATION
RELATIVE TO DATUM
COLUMN LINE
EXISTING CONCRETE FOOTING
UNDERPINNING
EXISTING WALL
WOOD BEARING WALL
W_X_
EXISTING STEEL BEAM
(E)W_X_
# REVISION
CMU OR STEEL LINTEL (SEE TYP. DETAILS)
L
TOP OF SLAB ELEVATION+#'-#"
_x_ @ _"
WOOD JOIST
INDICATES STEP DOWN
WALL OR CONCRETE
BEAM BELOW
METAL DECK (SEE SCHEDULE), OPEN
ARROW INDICATES SPAN DIRECTION
SLAB ON GRADE (SEE TYP. DETAIL)
R-#
S.O.G.
METAL GRATING FLOOR (SEE SCHEDULE),
OPEN ARROW INDICATES SPAN DIRECTION
G-#
STEEL COLUMN
EXISTING STEEL COLUMN
UP/DOWN
COLUMN ABOVE / BELOW
X WOOD CONNECTOR (SEE TYP. DETAILS
AND WOOD CONNECTOR SCHEDULE)
SUB SHEET NO. TITLE OF SHEET
OF
DATE:
TECH. REVIEW:
DESIGNED: DRAWING NO.
PMIS/PKG NO.
SHEET
142608
REHABILITATE ANTIETAM VISITOR CENTER
ANTIETAM NATIONAL BATTLEFIELD, MARYLAND
ANTI 225963
05/22/2020 195
LEGENDS AND
ABBREVIATIONS
S2
GM
AN
NH
B SEISMIC DESIGN CATEGORY
0.068 S(d1) 5-% DAMPED SPECTRAL RESPONSE COEFFICIENT AT 1-SECOND PERIODS
0.133 S(ds) 5-% DAMPED SPECTRAL RESPONSE COEFFICIENT AT SHORT PERIODS
D SITE CLASS
0.042 S1 1-SECOND PERIOD SPECTRAL RESPONSE ACCELERATION
0.125 Ss SHORT PERIOD SPECTRAL RESPONSE ACCELERATION
1 I SEISMIC IMPORTANCE FACTOR
SEISMIC DESIGN:
-0.18 GCPi INTERNAL PRESSURE COEFFICIENT
C WIND EXPOSURE CATEGORY
1 I WIND IMPORTANCE FACTOR
115 MPH BASIC WIND SPEED
WIND LOAD:
1 Ct THERMAL FACTOR 1 Is SNOW LOAD IMPORTANCE FACTOR 1 Ce SNOW EXPOSURE FACTOR 30 Pg GROUND SNOW LOAD
SNOW LOAD:
RISK CATEGORY: II
2018 INTERNATIONAL EXISTING BUILDING CODE
GOVERNING CODE: 2018 INTERNATIONAL BUILDING CODE
DESIGN PARAMETER TABLE
CONCRETE WALL SCHEDULE
MARK WIDTH
REINFORCEMENT
REMARKSVERTICAL HORIZONTAL
W1 18" #6@10" EF #6@12" EF
CONCRETE WALL FOOTING SCHEDULE
MARK
SIZE REINFORCEMENT
REMARKSWIDTH DEPTH
BOTTOM TOP
LONG WAY SHORT WAY LONG WAY SHORT WAY
WF1 10' - 0" 1' - 6" #6@12" #6@12" #6@12" #6@12" -
WF2 3' - 0" 1' - 6" #4@12" #4@12" #4@12" #4@12" -
SLAB/DECK SCHEDULE
MARK
TOTAL
DEPTH COMPOSITION/REINFORCEMENT
G1 1 1/2" 11-W-4 1-1/2"x 3/16" GALV. METAL GRATING BAND ALL EDGES
R1 1 1/2" 20 GA. GALV. TYPE 1.5C ROOF DECK
S.O.G. 5" 5" NW CONCRETE SLAB ON GRADE. SEE TYPICAL DETAIL
FOOTING SCHEDULE
MARK
SIZE REINFORCEMENT
REMARKSLENGTH WIDTH THICKNESS
BOTTOM BARS TOP BARS
LONG WAY SHORT WAY LONG WAY SHORT WAY
F1 3' - 6" 3' - 6" 1' - 6" 4-#6 4-#6 - - -
MASONRY WALL SCHEDULE
MARK
NOMINAL
THICKNESS
VERTICAL
REINFORCEMENT REMARKS
MW1 8" #4 @ 16" FULLY GROUTED. DOWELS SHOULD BE THE SAME AS THE VERTICAL BARS.
INSTALL LADDER REINFORCING PER GENERAL NOTES
WOOD CONNECTOR SCHEDULE
MARK JOIST SIZE CONNECTOR INFO
1 2x12 SIMPSON STRONG-TIE FACE-MOUNTED HANGER LU210 OR APPROVED EQUAL
2 2x8 SIMPSON STRONG-TIE FACE-MOUNTED HANGER LU26 OR APPROVED EQUAL
3 2x8 SIMPSON STRONG-TIE TOP FLANGE HANGER WP OR APPROVED EQUAL
(A) (B)
(C)
FURTHER INVESTIGATION NEEDED OF
(E) FOOTING; ONLY UNDERPIN IF
PIT IS WITHIN ZONE OF INFLUENCE
OF NEW ELEVATION CONTRACTOR
TO DIG TEST PIT TO DETERMINE IF
UNDERPINNING IS REQUIRED.
(A)
UNDERPIN
(E)WALL FOOTING
ELEVATOR PIT, SEE
TYPICAL DETAIL
DEMO EXISTING PORTION
OF FOOTING CONFLICTING
WITH PIT AND DOWEL
INTO PIT SLAB
UNDERPIN (E) SPREAD
FTG. AND TIE
TOGETHER
4' - 0"
CONC. RETAINING
WALL FOOTING
S.O.G.
S .O .G
S.O.G.
CONCRETE FOUNDATION
WALL, SEE SCHEDULE
NEW CONCRETE
STAIR ON GRADE,
SEE ARCH
SLAB ON GRADE,
SEE TYP. DETAILS
SLAB ON GRADE,
SEE TYP. DETAILS
CONCRETE SLAB ON
GRADE, SEE TYP.
DETAIL
SLAB TURNDOWN,
SEE TYP. DETAIL
NEW FOOTING BELOW CMU
WALL, SEE TYP. DETAIL
SLAB TURNDOWN,
SEE TYP. DETAIL
(E) COLUMN TO
BE REMOVED.
PROVIDE TEMP.
SHORING AS
REQ'D. LOCALLY
REPAIR S.O.G.
PER TYP. DETAIL
S12
0' - 0"
DOWEL NEW CONC.
WALL AND FTG INTO
EXIST.
WF1
[-7' - 3"]
W F
UP
-4' - 9"
DN
L1
L1
F1 [-2' - 6"]
W1
W
W1
0' - 0"
S12
WF2
[-7' - 3"]
NEW TO EXIST.
S.O.G., SEE TYP.
DETAIL
NEW TO EXIST.
S.O.G., SEE TYP.
DETAIL
NEW TO EXIST.
S.O.G., SEE TYP.
DETAIL
-8' - 0"
SUMP PIT, SEE
TYP. DETAIL
(E) S.O.G.
(E) S.O.G.
(E) B.O.F.
[-6'-0"]
(E) B.O.F.
[-4'-0"] REFERENCE TYPICAL STEEL LINTEL AT
OPENINGS IN EXISTING CONCRETE WALL
FOR MEP OPENINGS IN FALLOUT SHELTER
CONCRETE WALLS. COORDINATE OPENING
LOCATIONS WITH ARCH AND MEP
3' - 0"
OPENING IN (E) S.O.G. FOR SUMP
PUMP. COORDINATE LOCATION AND SIZE
WITH MEP. LOCATE SUMP SO THAT IT
DOES NOT CROSS ZONE OF INFLUENCE
OF EXISTING WALL FOOTINGS.
CONTRACTOR TO CONFIRM ZONE OF
INFLUENCE GEOMETRY WITH A GEOTECH.
(A)
(E) B.O.F.
[-6'-0"]
(A)
(E) B.O.F.
[-6'-0"]
F1 [-2' - 6"]
UNDERPIN (E)
WALL FTG
UNDERPIN (E) WALL FTG
3' - 6"
6' - 6"
GA
LV
H
SS
3X 3X 1/
GA
LV
H
SS
4X 2X 1/
"]M W
M W
MW1 MW1
M W
MW1
M W
MW1
7' - 10"
DUNNAGE FOR MEP UNIT, SEE MEP
DRAWINGS. COORD. LOCATION WITH MEP
2' - 6"
ALL DUNNAGE POSTS GALV. HSS3X3X1/4.
SEE TYP. DUNNAGE DETAIL FOR POST
BASE CONNECTION AT NEW S.O.G.
DUNNAGE FOR MEP UNIT, SEE MEP
DRAWINGS. COORD. LOCATION WITH MEP
EXIST. CONC. COL. V.I.F.
ALL DUNNAGE BEAMS GALV.
C5X9. SEE TYP. DUNNAGE DETAIL
DOWEL NEW CONC.
WALL AND FTG INTO
EXIST.
S12
5 4 3 12
B
C
D
E
9' - 0" 9' - 0" 9' - 0" 9' - 0"
0' - 5"
A
1' - 11"
4' - 2"
SHEET NOTES:
1. EXISTING FRAMING AND STRUCTURE NOTED ON PLAN IS BASED ON INFORMATION CONTAINED IN VARIOUS ORIGINAL DESIGN AND CONSTRUCTION DOCUMENTS PROVIDED BY THE OWNER, AS WELL AS LIMITED FIELD OBSERVATIONS AND MEASUREMENTS. CONTRACTOR TO NOTIFY DESIGN TEAM IF EXISTING CONDITIONS DO NOT MATCH AS-SHOWN ASSUMPTIONS. CONTRACTOR TO PROVIDE TEMPORARY BRACING AND SHORING, AS REQUIRED. CONTRACTOR IS RESPONSIBLE FOR STABILITY OF THE STRUCTURE UNTIL CONSTRUCTION REACHES ITS FINAL CONDITION.
2. SEE FOUNDATION TYPICAL DETAILS ON SHEETS S6-S8 AND SUPERSTRUCTURE TYPICAL DETAILS ON S9-S11.
3. SEE SCHEDULES AND LEGEND ON S2.
SUB SHEET NO. TITLE OF SHEET
OF
DATE:
TECH. REVIEW:
DESIGNED: DRAWING NO.
PMIS/PKG NO.
SHEET
142608
REHABILITATE ANTIETAM VISITOR CENTER
ANTIETAM NATIONAL BATTLEFIELD, MARYLAND
ANTI 225963
05/22/2020 195
FOUNDATION PLAN
S3
GM
AN
NH
1/8" = 1'-0"S3
1 FOUNDATION PLAN 1/8" = 1'-0"
8 0 8 16
SCALE OF FEET
(E) 2x12 @16" TO BE SHORED
DURING CONSTRUCTION
S12
CMU WALL,
SEE GENERAL NOTES
L1
RESUPPORT EXIST.
JOISTS ON MASONRY
WALL, SEE TYP. DETAILS
L
10K1 STEEL JOISTS @ 3'-0" O.C.
2x8 JOISTS @ 16"
2x8 JOISTS @ 16"
EXIST. STEEL JOISTS
OPEN
TIE CMU TO
EXISTING, SEE
TYP. DETAIL
NEW STAIR, INCL. TOP
LANDING, (BY OTHERS) @
EXISTING OPENING2
S12
BP-1 BP-1
BP-1
BP-1BP-1
BP-34x12 LEDGER, SEE TYP. DETAIL
G 1 6' - 0 3/4"
DN.
WP GALV. W10x12
< 5' - 11 1/4" >
GALV. W10x12
< 5' - 11 1/4" >
T.O. WALL= 7' - 9"
T.O. WALL= 7' - 9"
T.O. WALL= 7' - 9"
W8x21
< 11' - 2 1/2" >
W12x72
< 11' - 2 1/2" >
< 11' - 2 1/2" >
W12x40 < 11' - 2 1/2" >
S12
E Q
E Q
E Q
CONFIRM LINTEL SIZE
DURING DEMO TO
DETERMINE IF NEW
LINTEL IS REQUIRED
HSS6X4X1/4
2x8 JOISTS @ 16"
OUTLINE OF ROOF ABOVE
AT ENTRANCE, SEE ARCH
OUTLINE OF TRELLIS ABOVE AT
ENTRANCE. TRELLIS BY OTHERS.
SEE ARCH FOR LAYOUT, AND
MANUFACTURER TO PROVIDE
LOADS IMPARTED FOR REVIEW
W12x96
R1
BP-2
BP-2< 11' - 2 1/2" >
W12x58
W x
BP-3
STONE VENEER ON BOTH
SIDES OF WALL, SEE ARCH.
WP WP
WP
STONE VENEER ON
CMU, SEE ARCH
L2
L
NEW STEEL ANGLE LINTELS TO
SUPPORT MASONRY WALLS OF
CHIMNEY ABOVE, SEE TYP. DETAIL
HSS TO BEAR MIN. 6"
ON CMU WALL
ASSUMED EXIST. LINTEL SPANNING
ABOVE CONC. COL. BELOW. W/
NEW OPENINGS AND SHAFT WALL,
EXIST. LINTEL SHOULD NOT BE
AFFECTED. NOTIFY EOR IF EXIST.
CONDITION VARIES
EXIST. CONC. COL. BELOW. V.I.F.
EXIS. STEEL BEAM TO BE RE-
SUPPORTED ON NEW CMU SHAFT
WALL, SEE TYP. DETAIL. STEEL
BEAM TO BE V.I.F.
BP-3
BEAM CENTERED ON COLUMN,
SEE TYP. BEAM TO COLUMN
CONNECTION DETAIL
SEE TYP. JOIST BEARING ON
EXIST. MASONRY WALL DETAIL
5 4 3 12
B
C
D
E
9' - 0" 9' - 0" 9' - 0" 9' - 0"
0' - 5"
A
V .I . F
0' - 1 5/8"
EXIST. STEEL JOISTS
6" CMU WALL ABOVE ROOF W/
SAME REINFORCEMENT AS 8" CMU
WALL, SEE ARCH FOR DETAIL
RESUPPORT EXIST.
JOISTS ON CMU,
SEE TYP. DETAIL
R
W8x10 < 20' - 8" >
ROOF
TRELLIS BY OTHERS. SEE
ARCH FOR LAYOUT, AND
MANUFACTURER TO PROVIDE
LOADS IMPARTED FOR
REVIEW
BP-3
BP-3
SHEET NOTES:
1. EXISTING FRAMING AND STRUCTURE NOTED ON PLAN IS BASED ON INFORMATION CONTAINED IN VARIOUS ORIGINAL DESIGN AND CONSTRUCTION DOCUMENTS PROVIDED BY THE OWNER, AS WELL AS LIMITED FIELD OBSERVATIONS AND MEASUREMENTS. CONTRACTOR TO NOTIFY DESIGN TEAM IF EXISTING CONDITIONS DO NOT MATCH AS-SHOWN ASSUMPTIONS. CONTRACTOR TO PROVIDE TEMPORARY BRACING AND SHORING, AS REQUIRED. CONTRACTOR IS RESPONSIBLE FOR STABILITY OF THE STRUCTURE UNTIL CONSTRUCTION REACHES ITS FINAL CONDITION.
2. SEE FOUNDATION TYPICAL DETAILS ON SHEETS S6-S8 AND SUPERSTRUCTURE TYPICAL DETAILS ON S9-S11.
3. SEE SCHEDULES AND LEGEND ON S2.
SUB SHEET NO. TITLE OF SHEET
OF
DATE:
TECH. REVIEW:
DESIGNED: DRAWING NO.
PMIS/PKG NO.
SHEET
142608
REHABILITATE ANTIETAM VISITOR CENTER
ANTIETAM NATIONAL BATTLEFIELD, MARYLAND
ANTI 225963
05/22/2020 195
SECOND FLOOR AND
ROOF FRAMING PLAN
S4
GM
AN
NH
1/8" = 1'-0"S4
1 LEVEL 02 FRAMING PLAN
1/8" = 1'-0"S4
2 ROOF FRAMING PLAN
1/8" = 1'-0" 8 0 8 16
SCALE OF FEET
EXIST. 2x12 WOOD JOISTS @ 16"
O.C. ROOF FRAMING. V.I.F. SEE
TYPICAL PV PANEL SUPPORT POST
AT WOOD JOIST DETAIL
AREA OF NEW PV PANELS,
SEE ARCH
EXIST. 16" DEEP OPEN-WEB STEEL JOISTS @ 4'-0" O.C. ROOF FRAMING. V.I.F. SEE TYPICAL
PV PANEL SUPPORT POST AT OPEN WEB JOIST DETAIL. STEEL JOISTS WILL NEED TO BE
MEASURED AND EVALUATED ONCE THE ROOFING IS REMOVED AND THE LOADS IMPARTED ARE
PROVIDED BY THE PV PANEL MANUFACTURER. FOR PRICING PURPOSES, BID SHALL BE BASED
ON STEEL REINFORCEMENT TONNAGE OF 2 PSF OVER ROOF AREAS SUPPORTING PROPOSED
PANELS. ASSUMED FIELD WELDED LOCAL REINFORCEMENT OF WEB AND CHORD MEMBERS AND
NEW SECONDARY FRAMING OR WEB MEMBERS AT POINT OF SUPPORT. CONTRACTOR TO
PROVIDE PRICING FOR REINFORCEMENT AS A UNIT COST. ALL FIELD CONDITIONS TO BE
VERIFIED AND FINAL REINFORCEMENT DESIGN TO BE PERFORMED UNDER A DELEGATED DESIGN
ARRANGEMENT BY A QUALIFIED STRUCTURAL ENGINEER HIRED BY THE CONTRACTOR SUBMITTED
TO THE S.E.O.R. FOR CONFIRMATION AND APPROVAL.
AREA OF NEW
PV PANELS,
SEE ARCH
EXIST. 16" DEEP OPEN-WEB STEEL JOISTS @ 2'-0" O.C. ROOF FRAMING. V.I.F. SEE
TYPICAL PV PANEL SUPPORT POST AT OPEN WEB JOIST DETAIL. STEEL JOISTS WILL NEED
TO BE MEASURED AND EVALUATED ONCE THE ROOFING IS REMOVED AND THE LOADS
IMPARTED ARE PROVIDED BY THE PV PANEL MANUFACTURER. FOR PRICING PURPOSES,
BID SHALL BE BASED ON STEEL REINFORCEMENT TONNAGE OF 2 PSF OVER ROOF AREAS
SUPPORTING PROPOSED PANELS. ASSUMED FIELD WELDED LOCAL REINFORCEMENT OF WEB
AND CHORD MEMBERS AND NEW SECONDARY FRAMING OR WEB MEMBERS AT POINT OF
SUPPORT. CONTRACTOR TO PROVIDE PRICING FOR REINFORCEMENT AS A UNIT COST. ALL
FIELD CONDITIONS TO BE VERIFIED AND FINAL REINFORCEMENT DESIGN TO BE
PERFORMED UNDER A DELEGATED DESIGN ARRANGEMENT BY A QUALIFIED STRUCTURAL
ENGINEER HIRED BY THE CONTRACTOR SUBMITTED TO THE S.E.O.R. FOR CONFIRMATION
AND APPROVAL.
SHEET NOTES:
1. EXISTING FRAMING AND STRUCTURE NOTED ON PLAN IS BASED ON INFORMATION CONTAINED IN VARIOUS ORIGINAL DESIGN AND CONSTRUCTION DOCUMENTS PROVIDED BY THE OWNER, AS WELL AS LIMITED FIELD OBSERVATIONS AND MEASUREMENTS. CONTRACTOR TO NOTIFY DESIGN TEAM IF EXISTING CONDITIONS DO NOT MATCH AS-SHOWN ASSUMPTIONS. CONTRACTOR TO PROVIDE TEMPORARY BRACING AND SHORING, AS REQUIRED. CONTRACTOR IS RESPONSIBLE FOR STABILITY OF THE STRUCTURE UNTIL CONSTRUCTION REACHES ITS FINAL CONDITION.
2. SEE FOUNDATION TYPICAL DETAILS ON SHEETS S6-S8 AND SUPERSTRUCTURE TYPICAL DETAILS ON S9-S11.
3. SEE SCHEDULES AND LEGEND ON S2.
SUB SHEET NO. TITLE OF SHEET
OF
DATE:
TECH. REVIEW:
DESIGNED: DRAWING NO.
PMIS/PKG NO.
SHEET
142608
REHABILITATE ANTIETAM VISITOR CENTER
ANTIETAM NATIONAL BATTLEFIELD, MARYLAND
ANTI 225963
05/22/2020 195
PHOTOVOLTAIC PANELS
ROOF PLAN
S5
GM
AN
NH
1/8" = 1'-0"S5
1 LOW ROOF PLAN
1/8" = 1'-0"S5
2 HIGH ROOF PLAN
"L
IF
T
M A X
IM
U M
U N B R A C E D
L
IF
T
H E
IG
H T
F O R
D E E P
L
IF
T S
P R O V
ID
E
T E M P O R A
Y
B
A C E
F O
X
IS
T
IN
G
W A L L
A N
N
W
U N D E R P
IN
N
IN
G
(TYPICAL)
4' - 0" (MAX.)
(TYPICAL)
12' - 0" (MIN.)
FOR RUBBLE WALLS
3'-0" (MAX.) NEW CONCRETE UNDERPINNING
SEGMENTS SAME WIDTH AS
EXISTING FOOTING.
TAPERED STEEL SHIMS
AT 2'-0" O.C. (MAX.)
WITH 2" OF DRY PACK
ALL AROUND SHIMS
1. STARTING WITH SEGMENTS (A) ONLY, DIG PITS 4'-0" WIDE, MAXIMUM, SIMULTANEOUSLY PLACING REQUIRED SHEETING AND BRACING. ALL PITS TO BE SHEETED ON ALL FOUR SIDES. PACK VOIDS BETWEEN SHEETING AND SOIL WITH SOIL CEMENT.
(LEAVE A MINIMUM OF 12'-0" OF EXISTING SOIL BETWEEN PITS).
2. CLEAN BOTTOM OF EXISTING FOOTING AND RECOMPACT DISTURBED SOIL AT BOTTOM OF PIT WITH MECHANICAL PAN TAMPERS.
COMPACT TO 95% OF THE MAXIMUM DENSITY OF THE SOIL. LOSS OF GROUND SHOULD BE KEPT TO A MINIMUM BY BACKFILLING BEHIND THE BOARDS WHERE AND WHEN POSSIBLE WITH GROUT PUMPED INTO THE VOIDS.
3. THE CONTRACTOR SHALL INSTALL ADEQUATE LATERAL-BRACING SYSTEM(S) TO PREVENT MOVEMENT IN THE EXISTING
STRUCTURE(S) AND IN THE NEW UNDERPINNING.
4. POUR NEW CONCRETE UNDERPINNING FOR SEGMENTS (A) . AFTER CONCRETE ATTAINS 50% OF THE DESIGN STRENGTH, OR 96 HOURS, PLACE 2"x 4" TAPERED STEEL WEDGES AT 2'-0" O.C. MAX. THEN PACK SOLID WITH DRYPACK INTO SPACE BETWEEN TOP OF UNDERPINNING AND BOTTOM OF EXISTING FOOTING, TO TRANSFER LOAD. ENSURE THE BACK OF VOID IS
FORMED SO THAT DRYPACK IS NOT LOST WHEN RAMMED INTO THE GAPS.
5. FOR SEGMENTS (B) DIG PITS 4'-0", MAXIMUM, WIDE WITH REQUIRED SHEETING & BRACING.
6. FOR SEGMENTS (B) REPEAT CONCRETING, CLEANING, COMPACTION, STEEL WEDGES AND DRYPACKING AS DESCRIBED IN NOTES
2, 3 AND 4.
7. FOR SEGMENTS (C) DIG PITS 4'-0", MAXIMUM, WIDE WITH REQUIRED SHEETING & BRACING.
8. FOR SEGMENTS (C) REPEAT CONCRETING, CLEANING, COMPACTION, STEEL WEDGES AND DRYPACKING AS DESCRIBED IN NOTES
2, 3 AND 4.
9. FOR SEGMENTS (D), DIG OUT SOIL BETWEEN COMPLETED SEGMENTS (C) AND (A) PROVIDE SHEETING AND BRACING AS
REQUIRED.
10. FOR SEGMENTS (D) REPEAT CONCRETING, CLEANING, COMPACTION, STEEL WEDGES AND DRYPACKING AS DESCRIBED IN NOTES
2, 3 AND 4.
11. WHERE BOTTOM OF ADJACENT UNDERPINNING PITS ARE AT DIFFERENT ELEVATIONS, THE DEEPER PIT SHALL BE INSTALLED FIRST.
12. UNDERPINNING PITS CLOSER THAN 12' APART SHALL NOT BE EXCAVATED AT THE SAME TIME.
EXISTING WALL UNDERPINNING SEQUENCE:
NOTE: ALL SHEETING, CLEATS AND BRACING SHALL BE PRESSURE
TREATED LUMBER, SIZED IN ACCORDANCE WITH TABLE 19-1 OF
THE NEW YORK CITY BUILDING CODE.
SECTION OF WOOD SHEETING/BRACING - 1
MAXIMUM UNBRACED
LIFT HEIGHT =
4'-0"FOR DEEP
LIFTS PROVIDE
TEMPORARY BRACE
FOR EXISTING WALL
AND NEW
UNDERPINNING
TIMBER BRACES
(TYP.)
TIMBER SHEATHING
EXISTING STONE
OR CONC.
FOUNDATION TO
REMAIN
EXISTING STONE -
RUBBLE. CONC.
OR MASONRY
WALL TO REMAIN
UNDERSIDE OF
EXIST.
FOUNDATIONS TO
BE STIFF
BRUSHED AND
CLEANED TO
REMOVE ALL
LOOSE MATERIAL
PRIOR TO SHIMS
AND DRY PACK
(A) (B) (C) (D) (B)(A)(D)
SECTION OF CONCRETE UNDERPINNING - 2
TIMBER BRACES (TO REMAIN)
TIMBER SHEETING (TO REMAIN)
DRY PACK SHALL BE FORMED
AT REAR OF PIT AND SIDES OF PIT
EXISTING STONE -
RUBBLE. CONC.OR
MASONRY WALL TO REMAIN
TAPERED STEEL
SHIMS AT 2'-0"
O.C. (MAX.) WITH
2" OF DRY PACK
ALL AROUND SHIMS
TIMBER
CLEATS
EXPOSED FACE OF
CONC. SHALL BE
CLEAN & NEAT
NEW CONCRETE
UNDERPINNING WALL
TIMBER CLEATS (TO REMAIN)
EXISTING STONE OR CONC.
FOUNDATION TO REMAIN
ORIGINAL GRADE
LOWERED GRADE LOWERED GRADE
ORIGINAL GRADE
NEW CELLAR
ELEVATION
ELEVATOR PIT
(S E E
P L A N
P
IT
D E P T H
C L R
#5@12" O.C. TYP.
2"x4" KEYWAY
CONT. TOP & BOT.
TYP.
1' - 0"
BENTONITE WATER STOP (TYP.)
#4@12" O.C. TYP.
#5 NOSING BAR ALL
AROUND
1' - 4"
CLR.
0' - 3"
3" CONCRETE MUD SLAB
(ALL AROUND)
3' - 0"
WATERPROOFING ALL
AROUND PROVIDE
PROTECTION BOARD
(SEE ARCH'L DWGS.)
3" CONCRETE MUD LINE
#4@12" O.C. TYP.
#5@12" O.C. TYP.
NOTE: COORD. SLAB LEVELS ON ALL SIDES OF PIT W/ ARCH.
SLAB LEVELS VARY ON SIDES OF PIT.
#5 TOP AND
BOTTOM EACH WAY
WATERSTOP
#4 @ 12" O.C. VERTICAL
AND HORIZONTAL
#5 @ 12" O.C.1
S E E
P L A N
1' - 0" PIT MAT
SEE PLAN
1' - 0" CONC. WALL
1' - 0"
LAP SPLICE
TENSION
STANDARD HOOK
STANDARD HOOK
TEE-INTERSECTIONCORNER
NOTE: FOR TENSION LAP SPLICE LENGTH AND DEVELOPMENT
LENGTH SEE TABLE.
A P
S P L
IC
E
T E N S
IO
N
L A P
S P L
IC
E
T E N S
IO
N
UNDERPINNING
INDIVIDUAL UNDERPINNING SEGMENTSA B
C D
REINFORCEMENT COUPLER OR
SPLICE REINFORCEMENT BETWEEN
SEGMENTS
REINFORCEMENT
NOTE: THIS IS A CONCEPTUAL DETAIL FOR PROVIDING
REINFORCEMENT BETWEEN INDIVIDUAL UNDERPINNING
SEGMENTS TO TIE THE SEGMENTS TOGETHER.
UNDERPINNING AND REINFORCEMENT DESIGNED BY
OTHERS.
SUB SHEET NO. TITLE OF SHEET
OF
DATE:
TECH. REVIEW:
DESIGNED: DRAWING NO.
PMIS/PKG NO.
SHEET
142608
REHABILITATE ANTIETAM VISITOR CENTER
ANTIETAM NATIONAL BATTLEFIELD, MARYLAND
ANTI 225963
05/22/2020 195
FOUNDATION TYPICAL
DETAILS
S6
GM
AN
NH
1/4" = 1'-0"S6
1 TYPICAL UNDERPINNING
1/2" = 1'-0"S6
2 TYPICAL ELEVATOR PIT (EXTERIOR WATERPROOFING)
1/2" = 1'-0"S6
3 TYPICAL ELEVATOR SUMP PIT
3/4" = 1'-0"S6
TYPICAL HORIZONTAL REINFORCEMENT
AT CONCRETE WALL CORNERS
1/2" = 1'-0"S6
4 TYPICAL UNDERPINNING FOR SPREAD FOOTING DETAIL
W.W.R.
2"x3"
CONT. KEY
T H
IC
K N E S S
"t
A B
O N
G R A
T H
IC
K N E S S
"t
P T H
O F
T H
IC
K E N
A B
.5 x
S L A B
SAWED CONTRACTION JOINT
NOTE: MAXIMUM DISTANCE BETWEEN
CONTRACTION JOINTS IN INCHES
IS 36 TIMES SLAB THICKNESS
CONSTRUCTION JOINT
M
IN
0'
JOINTS
CONCRETE PIER
OR STEEL
COLUMN
(SEE PLAN)
SLAB ON GRADE
ISOLATION JOINT AT COLUMN
SLAB REINF.
(MESH REBAR)
ADDITIONAL REINFORCEMENT
AT ALL RE- ENTRANT CORNERS
SLAB
EDGE
2-#4 @ 3"x4'-0" LONG
ADDITIONAL AT ALL
RE-ENTRANT CORNERS
CONCRETE
SLAB
6"x6" W2.1 x W2.1 W.W.R.
10 MIL
POLYETHYLENE
VAPOR BARRIER
NOTES:
1. SLAB ON GRADE SHALL BE PLACED IN ALTERNATING STRIPS
WHERE EACH SINGLE STRIP DOES NO EXCEED 36 TIMES
SLAB THICKNESS WIDTH IN INCHES. ALTERNATIVELY, LARGE
BLOCK PLACEMENTS WITH INTERIOR CONTRACTION JOINTS
ARE ACCEPTABLE IF THE CONTRACTION JOINTS ARE MADE IN
BOTH DIRECTIONS AT SPECIFIED INTERVALS IN A TIMELY
MANNER.
2. SAWED CONTRACTION JOINTS SHALL BE LOCATED AT A
MAXIMUM SPACING IN INCHES OF 36 TIMES THE SLAB
THICKNESS. JOINTS SHALL BE SAWED NO LATER THAN 24
HOURS AFTER CONCRETE IS PLACED.
3. GRAVEL OR CRUSHED STONE BASE SHALL BE COMPACTED
TO 95% OF MAXIMUM DENSITY AT OPTIMUM MOISTURE
CONTENT.
C L R
6" GRAVEL OR
STONE
UNDISTURBED
SOIL OR FILL
SLAB ON GRADE
WATERSTOP
WATERSTOP. 2" COVER
MIN. E.S. (OR AS REQ'D
BY WATERSTOP MFR.)
VAPOR BARRIER
6" GRAVEL OR
CRUSHED STONE
UNDISTURBED SOIL
OR FILL
SLAB-ON-GRADE & WALL INTERFACE
U .N .O
SAW CUT
1-1/2" DEEP
8" SLAB
#4 NOSING BAR
0' - 1 1/2" CLEAR
W.W.F SIZE TO
MATCH S.O.G.
1" CLEAR
0' - 1" KICKBACK
2' - 0"
1 1/2" CLEAR
NOTE: POUR STAIR SLAB IN (2) 4" LIFTS TO
INSTALL SNOWMELT AT CENTER OF SLAB DEPTH
NOTES:
1. FOOTINGS SHALL BEAR ON FIRM UNDISTURBED SOIL WITH A MINIMUM
BEARING CAPACITY AS SPECIFIED IN THE GENERAL NOTES.
2. FOR SIZE, DEPTH AND REINFORCING SEE FOOTING SCHEDULE.
ISOLATION JOINT 1/2"
MIN. SEE TYPICAL
SLAB ON GRADE
DETAIL
GALV. COLUMN, SEE
PLAN AND COLUMN
SCHEDULE
C L R
0' - 3" CLR.
CONCRETE SLAB
ON GRADE
GALV. BASE PLATE,
SEE TYPICAL DETAIL
NON-SHRINK
GROUT, 2" MIN.
GALV. ANCHOR BOLTS,
SEE TYPICAL DETAILB.O. FTG.
EL. SEE PLAN
TYP.
3" MIN.
GALV. COLUMN, SEE PLAN
GALV. BASE PLATE, SEE
PLATE DIMENSIONS AND
ANCHOR LAYOUT BELOW
(4) 3/4" Ø GALV. HEADED
ANCHOR RODS. EMBED. 1'-4"
OR TO WITHIN 3" OF BOTTOM
OF FOOTING
NOTE: LEVELING
PLATES ARE NOT
PERMITTED
F
IN
IS
H
C O L U M N
ANCHOR BOLT
BASE PLATE
COLUMN, SEE PLAN
G R O U T
N O N S H R
IN
K
TOP ELEVATION
OF PLATE
BOTTOM ELEVATION
OF BASE PLATE
1/4
AT LATERAL
FRAME
COLUMNS
0' - 10"
0' - 1 1/2" 0' - 1 1/2"
M
IN
0' - 6"
DEVELOPMENT
LENGTH
#4 HOOKED BAR
@ 12"
#4 @ 12" O.C.
2' - 0" 0' - 6"
SAWCUT
EDGE OF
EXIST. SLAB
EXIST. SLAB
1/2" Ø SMOOTH DOWEL
x 2'-6" @ 18" O.C. (FIT SNUG
INTO DRILLED HOLE W/ EPOXY
OR GROUT AND COAT W/
NON-BONDING AGENT)
NEW SLAB
NOTE: DO NOT UNDERMINE EXIST. SLAB
0' - 4"
MATCH EXIST.
SLAB THICK.
ADDITIONAL #4
BAR @ 12"
#4 @ 48" O.C.
DOWELS AND REINF. (U.N.O.)
NEW LOAD BEARING BLOCK
WALL. SEE PLAN FOR SIZE
2-#5 CONT.
NOTES: FOOTINGS SHALL BEAR ON FIRM UNDISTURBED SOIL WITH A
MINIMUM BEARING CAPACITY AS SPECIFIED IN THE GENERAL NOTES.
2'-0"C L R
#5 @ 12" O.C.
SUB SHEET NO. TITLE OF SHEET
OF
DATE:
TECH. REVIEW:
DESIGNED: DRAWING NO.
PMIS/PKG NO.
SHEET
142608
REHABILITATE ANTIETAM VISITOR CENTER
ANTIETAM NATIONAL BATTLEFIELD, MARYLAND
ANTI 225963
05/22/2020 195
FOUNDATION TYPICAL
DETAILS
S7
GM
AN
NH
3/4" = 1'-0"S7
1 TYPICAL SLAB ON GRADE
1/2" = 1'-0"S7
4 TYPICAL STAIR ON GRADE
1/2" = 1'-0"S7
2 TYPICAL STEEL COLUMN ON CONCRETE FOOTING
1" = 1'-0"S7
3 TYPICAL COLUMN BASE PLATE AT HSS COLUMN
1" = 1'-0"S7
6 TYPICAL TURN-DOWN SLAB
1" = 1'-0"S7
TYPICAL ATTACHMENTS OF NEW SLAB
ON GRADE TO EXISTING
3/4" = 1'-0"S7
TYPICAL WALL FOOTING FOR LOAD BEARING CMU WALL AT
NEW SLAB
DEFORMED BAR TENSION DEVELOPMENT LENGTH (Ld)
FOR NORMAL WEIGHT STONE CONCRETE & UNCOATED BARS
BAR
SIZE
3000 PSI
CONCRETE
4000 PSI
CONCRETE
5000 PSI
CONCRETE
6000 PSI
CONCRETE
CASE 1 CASE 2 CASE 1 CASE 2 CASE 1 CASE 2 CASE 1 CASE 2
#3 17 25 15 22 13 20 12 18
#4 22 33 19 29 17 26 16 24
#5 28 42 24 36 22 32 20 30
#6 33 50 29 43 26 39 24 35
#7 48 72 42 63 38 56 34 51
#8 55 83 48 72 43 64 39 59
#9 62 93 54 81 48 72 44 66
#10 70 105 61 91 54 81 50 74
#11 78 116 67 101 60 90 55 82
DEFORMED TENSION BAR NOTES:
1. FOR HORIZONTAL REINFORCEMENT WITH 12 INCH OR MORE FRESH CONCRETE CAST BELOW IT, TENSION DEVELOPMENT LENGTH/ TENSION LAP SPLICE LENGTH SHALL BE 1.3X THE VALUES GIVEN.
2. FOR EPOXY-COATED BARS:
A. WHERE CONCRETE COVER IS LESS THAN 3X BAR DIAMETER, OR CLEAR SPACING IS LESS THAN 6X BAR
DIAMETER, TENSION DEVELOPMENT LENGTH/ TENSION LAP SPLICE LENGTH SHALL BE 1.5X THE VALUES GIVEN.
B. WHERE CONCRETE COVER IS EQUAL TO OR GREATER THAN 3X BAR DIAMETER AND CLEAR SPACING IS
GREATER THAN 6X BAR DIAMETER, TENSION DEVELOPMENT LENGTH/ TENSION LAP SPLICE LENGTH
SHALL BE 1.2X THE VALUES GIVEN.
CASE 1: CLEAR SPACING OF BARS BEING DEVELOPED OR SPLICED NOT LESS THAN DB, CLEAR COVER NOT LESS THAN DB, AND STIRRUPS OR TIES THROUGHOUT LD NOT LESS THAN THE CODE MINIMUM OR CLEAR SPACING OF BARS BEING DEVELOPED OR SPLICED NOT LESS THAN 2DB AND CLEAR COVER
NOT LESS THAN DB.
CASE 2: OTHER CASES
DEFORMED BAR TENSION LAP SPLICE - CLASS B
FOR NORMAL WEIGHT STONE CONCRETE & UNCOATED BARS
BAR
SIZE
3000 PSI
CONCRETE
4000 PSI
CONCRETE
5000 PSI
CONCRETE
6000 PSI
CONCRETE
CASE 1 CASE 2 CASE 1 CASE 2 CASE 1 CASE 2 CASE 1 CASE 2
#3 22 33 19 28 17 25 16 23
#4 29 43 25 37 23 34 21 31
#5 36 54 31 47 28 42 26 38
#6 43 65 37 56 34 50 31 46
#7 63 94 54 81 49 73 45 67
#8 72 107 62 93 56 83 51 76
#9 81 121 70 105 63 94 57 86
#10 91 136 79 118 71 106 64 96
#11 101 151 87 131 78 117 71 107
DEFORMED BAR COMPRESSION
DEVELOPMENT LENGTH (Ldc)
DEFORMED BAR COMPRESSION
LAP SPLICE
FOR NORMAL WEIGHT STONE CONCRETE &
UNCOATED BARS
FOR NORMAL WEIGHT STONE CONCRETE &
UNCOATED BARS
BAR
SIZE
3000 PSI
CONCRETE
4000 PSI
CONCRETE
5000 PSI
CONCRETE
6000 PSI
CONCRETE
BAR SIZE
3000 PSI
CONCRETE
4000 PSI
CONCRETE
5000 PSI
CONCRETE
6000 PSI
CONCRETE
#3 9 8 8 8 #3 12 12 12 12
#4 11 10 9 9 #4 15 15 15 15
#5 14 12 12 12 #5 19 19 19 19
#6 17 15 14 14 #6 23 23 23 23
#7 20 17 16 16 #7 27 27 27 27
#8 22 19 18 18 #8 30 30 30 30
#9 25 22 21 21 #9 34 34 34 34
#10 28 25 23 23 #10 39 39 39 39
#11 31 27 26 26 #11 43 43 43 43
PROVIDE #6x18" SMOOTH
(UNBOUNDED) DOWEL @
24" O.C.
SOIL SIDE
WATERPROOFING STRIP
SEE WALL SECTIONS
FOR REINF.
V-SHAPED KEY FILLED
WITH SEALANT
S E E
P L A N
SEE WALL SECTIONS
FOR REINF.
EXPOSED SIDE
NOTES:
1. PROVIDE CONTROL JOINTS AT A MAXIMUM OF 20 FEET O.C.
2. SEE TYPICAL WALL DETAIL AND ARCH. FOR WATERPROOFING
AND DRAINAGE REQUIREMENTS.
CUT ALTERNATING
HORIZONTAL REINFORCING
BARS AT CONTROL JOINT
ROUGHEN TO 1/4"
AMPLITUDE OR COAT
CONTACT SURFACE WITH
LATEX BONDING AGENT
HOOKED #3 DOWEL @
18" O.C. W/ MIN.
2-3/4" EMBEDMENT IN
HY-200 ADHESIVE OR
APPROVED EQUAL
SEE BELOW TABLE FOR
TYPICAL REINFORCING
AT SLAB ON GRADE
NOTES:
1. FOR SIZE AND LOCATION SEE ARCHITECTURAL AND MECHANICAL DRAWINGS.
2. CONCRETE FOR PADS SHALL BE NORMAL WEIGHT WITH f'c = 4,000 PSI.
M A X
EQUIPMENT PAD TEMPERATURE AND
SHRINKAGE REINFORCING
REINFORCINGPAD THICKNESS
#3 @ 12" O.C. EACH WAY4"-5"
#4 @ 12" O.C. EACH WAY6"-9"
#5 @ 12" O.C. EACH WAY10"-12"
SUB SHEET NO. TITLE OF SHEET
OF
DATE:
TECH. REVIEW:
DESIGNED: DRAWING NO.
PMIS/PKG NO.
SHEET
142608
REHABILITATE ANTIETAM VISITOR CENTER
ANTIETAM NATIONAL BATTLEFIELD, MARYLAND
ANTI 225963
05/22/2020 195
FOUNDATION TYPICAL
DETAILS
S8
GM
AN
NH
1" = 1'-0"S8
1 TYPICAL CONTROL JOINT IN CONCRETE WALL
3/4" = 1'-0"S8
2 TYPICAL EQUIPMENT PAD
LINTEL BOND BEAM BLOCK
HORIZONTAL
REINFORCING, SEE
SCHEDULE
BEAM THICKNESS
SEE SCHEDULE
BEAM DEPTH
SEE SCHEDULE
CMU BOND BEAM SCHEDULE
LENGTH
BEAM
THICKNESS
BEAM DEPTH
HORIZONTAL
REINF.
SHEAR
REINF.
0'-0" - 6'-0" 8" 8"
(1 COURSE HIGH)
1-#5
NOTES:
1. ALL BOND BEAM BEAMS TO BE GROUTED SOLID FOR FULL LENGTH OF BEAM.
2. ALL CMU BOND BEAM TO HAVE MIN. 6" BEARING ON EACH END.
3. ALL BOND BEAMS (SPANNING) WITH NO MASONRY ABOVE TO BE SINGLE
COURSE WITH 1-#5 HORIZONTAL REINFORCING.
4. ALL OTHER (NON-SPANNING) BOND BEAMS TO BE SINGLE COURSE WITH 2-#4
HORIZONTAL REINFORCING.
5. VERTICAL PLACEMENT OF HORIZONTAL REINFORCEMENT IN ALL BOND BEAMS
SHALL BE 3" FROM THE BOTTOM OF THE BEAM TO CENTER OF BAR, U.N.O.
LINTEL REINFORCEMENT SHALL BE SUPPORTED BY WIRE CHAIRS.
6. HORIZONTAL PLACEMENT BETWEEN PARALLEL BARS SHALL NOT BE LESS THAN
THE NOMINAL DIAMETER OF THE BARS OR 1".
TOP FLANGE OF JOIST BEARS
ON NEW MASONRY WALL.
PROVIDE L2X2X1/2X0'-6"
CLIP ANGLES ON EITHER
SIDE OF FLANGE TO
FACILITATE BEARING ON
MASONRY
NEW ELEVATOR
SHAFT WALL
L3x3X1/4 CONTINUOUS W/ 3/4" Ø
ANCHORS @ 16"O.C. AND 5" MIN EMBED
USING HILTI HY270 ADHESIVE FOR ERECTION
PURPOSES AS NEEDED
EXIST. STEEL JOIST
NOTE: FLOOR SLAB AND WALL REINFORCEMENT NOT SHOWN FOR CLARITY.
1/4
TYP.
1/4
TYP.
ADDITIONAL WEB BAR
TO MATCH EXIST.
1/4
TYP.
PROVIDE CONT. EXPANSIVE
STRIP WATERSTOP
2-#4 CONT.
EXTERIOR FACE
NEW FULLY-GROUTED
CMU WALL
#4 x 24" @ 16" VERT.
IN HILTI HIT HY270 (MIN. 6" EMBED)
EXIST.
MASONRY
WALL
NOTE: FOR CONNECTION OF NEW CONC. TO
CONCRETE WALL, USE HILTI HY200 AND PROVIDE
SIMILAR HOOKED BAR.
PACK SOLID WITH MASONRY
AND/ OR GROUT
DRYPACK
NEW ANGLE LINTELS. PROVIDE ONE FOR
EACH 4" WALL WIDTH. SEE PLAN OR
SCHEDULE FOR SIZE. BEAR LINTELS, 6"
AT EACH END
EXISTING MASONRY WALL
EMBED BRG. PL.
3/8"x8"x6" w/ (2)
3/4" DIA. HEADED
ANCHORS (14" MIN.
EMBED.)
ROOF DECK
L3x3x1/4 CONT.
0' - 6"
TYP.
CMU BRG. WALL, SEE
PLAN FOR THK. &
REINF.
BOTTOM OF STRUCTURE ABOVE
FLOOR
W A L L
S P A N
1 1 1 2 2 2 2
NOT ALLOWED
WALL OPENING
NOTES:
1. S=1.5d MIN., LARGER d GOVERNS.
2. NO BEAM BEARING ABOVE OPENINGS.
3. DIMENSION A IS NOT RESTRICTED FOR CONTINUOUS CONCRETE SLAB BEARING.
A=12" MIN. BELOW UNTOPPED DECK.
4. VERTICAL ALIGNMENTS OF STACKED OPENINGS IS REQUIRED. STACKING OPENINGS
VERTICAL IN LIEU OF WIDE HORIZONTAL ROWS IS PREFERRED.
5. SEE 2/S9 FOR LINTELS WHEN ABOVE LAYOUT CANNOT BE ACHIEVED.
6. MAX. CORE SIZE = 12".
7. * DENOTES NO RESTRICTIONS IN NUMBER IF VERTICALLY ALIGNED
d S d S d S d
S
S
2' - 8" MAX. (SEE NOTE 2)12" MIN.
UNDISTURBED
SECTION E.S.
(S E E
N O T E
A
M
IN
WIDTH
5' - 0" MAX.
H E I G H T
M A X
BOTTOM OF EXIST.
CONCRETE SLAB OR
CONCRETE RIB JOIST
1/2" DIAM. ANCHOR
INSTALLED WITH HILTI HIT-
HY 200 WITH 4 1/2" MIN.
EMBEDMENT AND 3" MIN.
EDGE DISTANCE. INSTALL 2
AT EACH END AND THEN
STAGGER AT 16" O.C.
NOTE:
1. DETAIL APPLIES TO EXISTING CONCRETE WALL WITH ASSUMED THICKNESS
OF 12" BASED ON EXISTING DOCUMENTATION.
2. NOTIFY EOR IF ANY ADJACENT OPENINGS ARE WITHIN 3'-0" OF OPENING.
C10x20
TYP.
0' - 3"
T Y P
TYP.
0' - 6"
EXIST. CONCRETE WALL
COORD. SIZE OF POST
W/ FRAME BY PV…