ATTACHMENT V - 2021 BUILD 1 LIFE SAFETY DRAWINGS.pdf

PDF 24 MB Posted

Attached to
Z1DA--Upgrade Fire Alarm System 583-26-221 Federal contract opportunity
Solicitation number
36C25025B0039
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

This PDF contains Statement of Conditions (SOC) architectural drawings for Building 1 at the Richard L. Roudebush VA Medical Center in Indianapolis, Indiana. The comprehensive set of floor plans details fire protection, life safety, and occupancy zone configurations across 11 floors (basement through eleventh floor), with each floor displaying a detailed color-coded partition legend indicating fire barrier types, exit routes, and occupancy zones.

The drawings systematically document wall descriptions, fire barrier classifications, smoke zone barriers, and compartmentalization strategies, referencing the 2018 edition of NFPA 101 Life Safety Code. Each floor plan includes specific zone designations, highlighting areas of mixed occupancy types such as business, healthcare, industrial, and ambulatory care. The drawings are part of a fire alarm system upgrade project, showing precise architectural details about how different building zones are constructed and separated to ensure life safety and comply with federal fire protection standards.

View the file

Other files for this federal contract opportunity

Other files attached to Z1DA--Upgrade Fire Alarm System 583-26-221, newest first.
File Type Posted
36C25025B0039 0006.docx DOCX document
VAAR 852.219-75.docx DOCX document
Clarification.pdf PDF
36C25025B0039 0005.docx DOCX document
36C25025B0039 0004.docx DOCX document
RFI clarification responses.pdf PDF
36C25025B0039 0003.docx DOCX document
VHA ICRA 1.3_Final.pdf PDF
Wage Determination updated.pdf PDF
Sign in sheet.pdf PDF
36C25025B0039 0002.docx DOCX document
36C25025B0039 0001.docx DOCX document
ATTACHMENT XII - LIMITATIONS ON SUBCONTRACTING CERTIFICATE OF COMPLIANCE.pdf PDF
ATTACHMENT VII - Annual CTI 2019 Building 9 - Aadco Alarm BUILDING 9 CSR.pdf PDF
ATTACHMENT III - FA System Equipment Inventory.pdf PDF
ATTACHMENT XIII - SOLE SOURCE SIEMENS PANEL.pdf PDF
ATTACHMENT X - 583-26-221 Upgrade Fire Alarm System - Combined Specifications - Bid Alt.pdf PDF
ATTACHMENT II - FIRE ALARM DEVICE LOCATION LIST.pdf PDF
ATTACHMENT I - Fire-Life Safety System Inspection Testing and Maintenance Certificate_121723.pdf PDF
ATTACHMENT VI - Building 7-CSR - Fire Protection BUILDING 7 CSR.pdf PDF
ATTACHMENT XIV - RFI FORM.docx DOCX document
ATTACHMENT XI - WAGE DETERMINATION.pdf PDF
ATTACHMENT IX - Build 43 Coumadin Clinic -Fire Alarm Layout BUILDING 43 CSR.pdf PDF
ATTACHMENT VIII - Vet House CTI - 2019 - Aadco Alarm BUILDING 42 CSR.pdf PDF
ATTACHMENT IV - VA 583-13-104 FIRE ALARM AS-BUILTS.pdf PDF
36C25025B0039_1.docx DOCX document
Show all 26

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WALL:

DUCTS:

PENETRATIONS:

DOORS*:

WALL:

DUCTS:

DOORS:

WALL:

DUCTS:

PENETRATIONS:

DOORS:

WALL:

DUCTS:

DOORS:

2-HOUR FIRE BARRIER

THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND STAIRWELLS OF

4 OR MORE STORIES.

2-HOUR FIRE AND SMOKE ZONE BARRIER

THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND

STAIRWELLS OF 4 OR MORE STORIES. THIS COMBINATION WALL IS WHERE A PORTION

OF THE 2-HOUR RATED WALL IS ALSO PART OF THE SMOKE WALL.

1-HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

THIS APPLIES TO 1-HOUR FIRE RATED OCCUPANCY SEPERATIONS, HAZARDOUS ROOM

ENCLOSURES AND STAIRWELLS 3 STORIES OR LESS.

SMOKE ZONE BARRIER

SUBSTANTIAL WALLS AND DOORS TO DIVIDE EACH FLOOR INTO COMPARTMENTS FOR

DEFEND IN PLACE EMERGENCY OPERATIONS. IF THE SMOKE ZONE BARRIER WALL IS

OF MASONRY, GYPSUM BOARD, OR METAL LATH AND PLASTER CONSTRUCTION, AND

THE BARRIER WAS CONSTRUCTED POST 1948, THE SMOKE ZONE BARRIER WALLS ARE

REQUIRED TO BE OF 1 HOUR FIRE RESISTANCE RATING. (NFPA 101, 18.3.2.7.5) SMOKE

ZONE BARRIER WALLS OF WOOD LATH AND PLASTER CONSTRUCTION ARE PERMITTED

TO BE OF A 12 HOUR FIRE RESISTANCE RATING (NFPA 101, 19.3.7.3)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

NOTE: ALL CODE REFERENCES ARE PER THE 2018 EDITION OF NFPA 101 LIFE SAFETY CODE AND THE OTHER APPLICABLE CODES. FEDERAL FACILITIES FOLLOW 2018 LIFE SAFETY CODE.

DOORS: DOORS THAT ARE NOT PART OF A RATED WALL:

1. NON-LABELED FRAME (NFPA 101 18.3.6.3.1, 19.3.6.3 & 19.3.6.3.3)

2. NON-RATED DOORS PERMITTED IF SPRINKLERED (NFPA 101

18.3.6.3.1, 19.3.6.3.2(2))

3. 20-MINUTE OR SOLID WOOD CORE DOOR IF NOT SPRINKLERED (NFPA 101 19.3.6.3.1) 1 3 4" THICK.

4. POSITIVE LATCHING EXCEPT TOILETS, SHOWER AND SINK

CLOSETS (NFPA 101 18.3.6.3.6 & 19.3.6.3.6)

5. SELF-CLOSING NOT REQUIRED (NFPA 101 19.3.6.3.11)

6. NO MAXIMUM GAP (NFPA 101 18.3.6.3.1 & 19.3.6.3.3)

7. MAXIMUM 1" UNDERCUT (NFPA 101 18.3.6.3.1 & 19.3.6.3.4)

8. UNLIMITED HEIGHT PROTECTIVE PLATE (NFPA 101 18/19.3.6.3.12)

9. TRANSFER GRILLS NOT PERMITTED EXCEPT TOILETS,

SHOWER AND SINK CLOSETS (NFPA 101 18/19.3.6.4)

10. SWING IN ANY DIRECTION

11. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105 5.2.1.1)

NON-RATED SMOKE ZONE PARTITION

FORMER DECOMMISSIONED SMOKE BARRIER RETAINED AS FIRE ALARM/SPRINKLER

ZONE. BUILDING OCCUPANTS PERMITTED TO DEFEND IN PLACE UNTIL DIRECTED BY

THE FIRE DEPARTMENT PER SECTION 16.7.4.3 OF NFPA 99-2018 EDITION AND PRIVATE

MODE AUDIBLE REQUIREMENTS OF SECTION 16.7.4.3 OF NFPA 72-2019 EDITION.

WALL:

DUCTS:

PENETRATIONS:

DOORS:

HEALTH CARE OCCUPANCY CORRIDORS

IF THE SMOKE COMPARTMENT IS SPRINKLERED, THE WALL SHALL FORM A BARRIER TO LIMIT THE TRANSFER OF SMOKE. THE WALL HAS NO REQUIRED FIRE RESISTANCE RATING AND MAY TERMINATE AT A CEILING CONSTRUCTED

TO LIMIT TRANSFER OF SMOKE.

IF THE SMOKE COMPARTMENT IS NOT SPRINKLERED, THE WALL SHALL BE CONTINUOUS FROM THE FLOOR TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK ABOVE. CORRIDOR WALL SHALL HAVE A MINIMUM 1/2 HOUR FIRE RESISTANCE RATING. DOORS ARE MANUALLY CLOSED IN AN EMERGENCY NFPA 101 19.3.6.2 AND 18.3.6.2

PENETRATIONS:

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

ALL DUCT PENETRATIONS ARE PROTECTED BY FIRE DAMPERS.

ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP

MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL

PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE

WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON

THE TOP OF THE FLOOR.

ALL DOORS REQUIRE THE FOLLOWING:

1. LABELED FRAMES (NFPA 80 4.2.1)

2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)

3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 TABLE 4.4.5)-LIMITED TO

MAX AREA LISTED.

4. POSITIVE LATCHING (NFPA 80 6.4.1.4)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)

6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)

7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)

8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)

9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)

10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).

11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT

LEAST ANNUALLY (NFPA 80 5.2.4.1)

* 2 HOUR DOOR REQUIRED FOR STAIRWELLS 4 OR MORE STORIES

(NFPA 101 7.1.3.2.1)(3).

WALL:

DUCTS:

PENETRATIONS:

DOORS:

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

ALL DUCT PENETRATIONS ARE PROTECTED BY COMBINATION FIRE AND

SMOKE DAMPERS. SMOKE DAMPERS ARE NOT REQUIRED WHERE

ADJACENT SMOKE COMPARTMENTS ARE PROTECTED BY QUICK

RESPONSE SPRINKLERS THROUGHOUT EACH COMPARTMENT.

ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP

MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL

PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE

WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON

THE TOP OF THE FLOOR.

ALL DOORS REQUIRE THE FOLLOWING:

1. LABELED FRAMES (NFPA 80 4.2.1)

2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)

3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)

4. POSITIVE LATCHING (NFPA 80 6.4.1.4)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)

6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)

7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)

8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)

9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)

10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).

11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT

LEAST ANNUALLY (NFPA 80 5.2.4.1)

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

STEEL DUCT PENETRATIONS NOT REQUIRED TO BE PROTECTED BY FIRE

DAMPERS.

ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR

PROTECTING 1-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED

TO BE FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY

REQUIRED TO BE FILLED ON THE TOP OF THE FLOOR.

ALL DOORS REQUIRE THE FOLLOWING:

1. LABELED FRAMES (NFPA 80 4.2.1)

2. LABELED 3/4 OR 1-HOUR DOOR (NFPA 80 4.3.1)*

3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 TABLE 4.4.5)

4. POSITIVE LATCHING (NFPA 80 6.4.1.4)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)

6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)

7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)

8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)

9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)

10.SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).

11.PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT LEAST

ANNUALLY (NFPA 80 5.2.4.1)

* 1-HOUR DOORS ARE REQUIRED IN STAIRWELLS THAT ARE 3 STORIES OR

LESS. (NFPA101 7.1.3.2.1)(1)

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

ALL DUCT PENETRATIONS ARE PROTECTED BY SMOKE DAMPERS. SMOKE

DAMPERS ARE NOT REQUIRED WHERE ADJACENT SMOKE COMPARTMENTS ARE

PROTECTED BY QUICK RESPONSE SPRINKLERS THROUGHOUT EACH

COMPARTMENT.

ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR

PROTECTING 1-HOUR FIRE AND SMOKE WALL ASSEMBLIES. PENETRATIONS ARE

TO BE FILLED ON BOTH SIDES OF THE WALL.

ALL DOORS FOR SMOKE BARRIERS REQUIRE THE FOLLOWING:

1. NON-LABELED FRAME (NFPA 101 18.3.7.6)

2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 18.3.7.6) 1 3 4" THICK.

3. MAXIMUM SIZE LISTED WINDOW (NFPA 80 TABLES 4.4.5)

4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 18.3.7.8)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 18.3.7.8)

6. MAXIMUM 1/8" GAP (NFPA 101 18.3.7.6.)

7. MAXIMUM 3/4" UNDERCUT (NFPA 101 8.5.4)

8. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1

9. SWING IN DIRECTION OPPOSITE OF EACH OTHER (NFPA 101 18.3.7.6)

10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105

5.2.1.1)

IF THE HAZARDOUS ROOM HAS A SUSPENDED CEILING CONSTRUCTED TO LIMIT

TRANSFER OF SMOKE, THE WALL HAS NO FIRE RESISTANCE RATING AND MAY

TERMINATE AT THE CEILING. IF THE ROOM DOES NOT HAVE A SUSPENDED

CEILING, THE WALL HAS NO FIRE RESISTANCE RATING AND SHALL EXTEND TO

THE DECK ABOVE.

STEEL DUCT PENETRATIONS ARE NOT REQUIRED TO BE PROTECTED BY FIRE

DAMPERS OR SMOKE DAMPERS.

SEALED WITH NON-FIRE-RATED MATERIALS TO BE RESISTIVE. USE OF LISTED

FIRESTOP MATERIALS IS NOT REQUIRED.

EXISTING HAZARDOUS ROOMS:

1. NON-LABELED FRAME (NFPA 101 19.3.7.9)

2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 19.3.7.6) 1 3 4" THICK.

3. MAXIMUM 1296 SQ. IN. WINDOW (NFPA 101 19.3.6.3.17)

4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 19.3.6.3.5)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 19.3.2.1.3)

6. MAXIMUM 1/8" GAP (NFPA 101 19.3.6.3.1)

7. MAXIMUM 1" UNDERCUT (NFPA 101 19.3.6.3.4)

8. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 19.3.2.1.2)

9. SWING IN ANY DIRECTION

10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA

105 5.2.1.1)

PENETRATIONS:

WALL EXTENDS FROM FLOOR TO SUSPENDED CEILING OR DECK ABOVE.

NO MINIMUM REQUIREMENTS.

NO MINIMUM REQUIREMENTS FOR WALL PENETRATIONS ABOVE A SUSPENDED

CEILING. PENETRATIONS BELOW A SUSPENDED CEILING OR DECK SEALED

WITH NON-FIRE-RATED MATERIALS TO BE SMOKE RESISTIVE.

NON-FIRE-RATED DOORS AND FRAMES SELF CLOSING OR AUTOMATIC CLOSING

IN AN EMERGENCY.

EW

FAAP

FACP

F

AED

SH

EVC

FHV

SYMBOLS LIST

SUITE DESIGNATION

HEALTHCARE AREA OPEN TO CORRIDOR WITH 24

7 SUPERVISION - NO SMOKE

DETECTION REQUIRED.

HEALTHCARE AREA OPEN TO CORRIDOR - SMOKE DETECTION PROVIDED.

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

DATEREVISIONS: NUMBER

DRAFT SOC

FP&C Project Number Project NumberProject Title

Location

Issue Date Checked by Drawn by

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE

FVO KW Dwg. of

1557.31

INDIANAPOLIS, IN

UPDATE STATEMENT OF

CONDITIONS

RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC

1481 W. 10th Street Indianapolis, IN 46202

VA PLANNING AND ENGINEERING X-1

583-19-506

1/15/2021 6/1/20

STATEMENT OF CONDITIONS

WALL DESCRIPTIONS

COVER PAGE

FINAL SOC 9/16/20

DRAFT OUTER BUILDINGS 10/05/20

DRAFT OUTER BUILDINGS 2 12/18/20

1/15/21 UPDATED FINAL SOC

APPLICABLE CODES AND STANDARDS:

1. THE ORIGINAL BUILDING WAS BUILT IN 1982 AND DESIGNED TO THE UNIFORM BUILDING CODE 1979

EDITION.

2. THE JOINT COMMISION HAS ADOPTED THE NATIONAL FIRE CODES PUBLISHED BY THE NATIONAL FIRE

PROTECTION ASSOCIATION. LIFE SAFETY REQUIREMENTS ARE SPECIFICALLY ADDRESSED IN THE 2012

EDITION OF NFPA 101, LIFE SAFETY CODE.

3. ALL NEW CONSTRUCTION OR BUILDING RENOVATIONS ARE REQUIRED TO COMPLY WITH THE 2012 EDITION OF NFPA 101 OR IT'S REFERENCED STANDARDS. EXISTING BUILDING CONDITIONS ARE REQUIRED TO COMPLY WITH THE APPLICABLE CODES OR STANDARDS AT THE TIME OF BUILDING DESIGN AND THE APPLICABLE PROVISIONS FOR EXISTING BUILDINGS IN CURRENT EDITIONS OF APPLICABLE

CODES AND STANDARDS.

4. OTHER NFPA CODES AND STANDARDS:

A. NFPA 10 - PORTABLE FIRE EXTINGUISHERS, 2010 EDITION.

B. NFPA 13 - SPRINKLER SYSTEMS, 2010 EDITION.

C. NFPA 14 - STANDPIPE SYSTEMS, 2010 EDITION.

D. NFPA 20 - FIRE PUMPS, 2019 EDITION

E. NFPA 70 - NATIONAL ELECTRIC CODE, 2011 EDITION.

F. NFPA 72 - NATIONAL FIRE ALARM CODE, 2010 EDITION.

G. NFPA 75 - ELECTRONIC COMPUTER EQUIPMENT, 2017 EDITION.

H. NFPA 80 - FIRE DOORS, 2010 EDITION.

I. NFPA 90A&B - HEATING AND AIR CONDITIONING SYSTEMS, 2012 EDITION.

J. NFPA 96 - COMMERCIAL COOKING EQUIPMENT, 2011 EDITION.

K. NFPA 99 - HEALTH CARE FACILITIES CODE, 2012 EDITION.

L. NFPA 105 - SMOKE DOORS, 2010 EDITION.

M. NFPA 110 - EMERGENCY POWER SYSTEMS, 2010 EDITION.

N. NFPA 241 - CONSTITUTION AND DEMOLITION, 2009 EDITION.

FIRE SPRINKLER SYSTEM:

1. THE COMBINATION STANDPIPE AND FIRE SPRINKLER SYSTEM WAS DESIGNED TO NFPA 13 AND NFPA 14.

2. QUICK RESPONSE TYPE SPRINKLERS ARE INSTALLED THROUGHOUT MOST OF THE BUILDING. STANDARD RESPONSE TYPE SPRINKLERS ARE INSTALLED IN THE ELEVATOR MACHINE ROOMS (NFPA 13- 3.6.4.8).

3. SPRINKLERS WERE INSTALLED IN LIGHT HAZARD AREAS INCLUDING; CORRIDORS, OFFICES, PATIENT CARE AND PATIENT SLEEPING ROOMS AT LIGHT HAZARD 0.10 GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION

AREA OF 225 SQ. FT. (NFPA 13- TABLE 11.2.3.1.2).

4. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP I AREAS INCLUDING; LABORATORIES (WITHOUT FLAMMABLE LIQUIDS), MECHANICAL EQUIPMENT ROOMS, ELECTRICAL SWITCH GEAR ROOMS, REPAIR

SHOPS AND STORAGE ROOMS UNDER 250 SQ. FT. AT A 0.15 GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION AREA OF 150 SQ. FT. (NFPA 13- TABLE 11.2.3.1.2).

5. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP II AREAS INCLUDING GENERAL STORAGE ROOMS OVER 250 SQ. FT. AND LABORATORIES (WITH THE USE OF FLAMMABLE LIQUIDS) AT A 0.20 GPM/1500 SQ.

FT. DENSITY.

6. MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY SPRINKLERS SHALL NOT EXCEED 7'-6" (NFPA 13-8.6.3.2.1). MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY

SPRINKLERS IN SMALL ROOMS (800 SQ. FT. MAXIMUM) SHALL NOT EXCEED 9' FROM ANY SINGLE WALL (NFPA 13-8.6.3.2.4).

7. SPRINKLERS SHALL BE INSTALLED UNDER FIXED OBSTRUCTIONS (I.E. DUCTWORK) OVER 4' WIDE (NFPA 13- 8.10.6.3.2). THE WIDTH OF DUCT INSULATION NOT A FACTOR FOR SPRINKLERS INSTALLED PRIOR TO THE

2013 EDITION ON NFPA 13. SPRINKLERS NOT REQUIRED UNDER NON COMBUSTIBLE OBSTRUCTIONS OVER 4' WIDE WHERE THE BOTTOM OF THE OBSTRUCTION IS A MAXIMUM 24" ABOVE THE FLOOR (NFPA 13- 8.5.5.3.1).

8. SPRINKLERS SHALL BE INSTALLED A MAXIMUM 12" BELOW A CEILING OR FLOOR/ROOF DECK (NFPA 13- 8.6.4.1.1.1) OR A MAXIMUM 22" BELOW A FLOOR/ROOF DECK WITH STRUCTURAL MEMBER OBSTRUCTIONS (NFPA 13- 8.6.4.1.2).

9. SHELVING ON A WALL OR SHELVING AGAINST A WALL INCLUDING STORAGE THEREON SHALL BE PERMITTED TO EXTEND WITHIN THE 18" SPRINKLERS CLEARANCE BELOW CEILING SPRINKLER DEFLECTORS (NFPA 13- 8.5.6.1).

10. WHERE THE 18" CLEARANCE BETWEEN SPRINKLERS AND SHELVING STORAGE CANNOT BE MAINTAINED, SPRINKLERS SHALL BE INSTALLED IN EVERY AISLE (NFPA 13- 8.15.9(2)).

11. CEILING MOUNTED OBSTRUCTIONS (I.E. PATIENT LIFT TRACKS) WITHIN THE 18" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 TABLE 8.6.5.1.2 AND FIGURE 8.6.5.1.2(a).

12. FLOOR MOUNTED OBSTRUCTIONS (I.E. ROOM DIVIDERS OR SHELVING) WITHIN THE 18" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 TABLE 8.6.5.2.2 AND FIGURE 8.6.5.2.2.

SUITES:

1. SUITES ARE UTILIZED TO ILLUSTRATE AREAS WITH THE SAME FUNCTION, USE OF HALLWAYS OR

AISLES AND TO DEFINE THE END OF PUBLIC EXIT CORRIDORS. NO EXIT SIGNS OUTSIDE OF THE

SUITE MAY DIRECT OCCUPANTS INTO A SUITE TO REACH AN EXIT.

2. HEALTH CARE OCCUPANCY SUITES ARE REGULATED BY FUNCTION AND SIZE.

3. HEALTH CARE OCCUPANCY PATIENT SLEEPING SUITES:

A. SINGLE EXIT SUITE - 1,000 SQ. FT. (NFPA 101 -19.2.5.7.2.2)

B. MULTI EXIT SUITE - 5,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.A)

C. MULTI EXIT SUITE WITH STANDARD RESPONSE SPRINKLERS OR COMPLETE SMOKE DETECTION

- 7,500 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.B)

D. MULTI EXIT SUITE WITH DIRECT VISUAL SUPERVISION, QUICK RESPONSE SPRINKLERS AND

COMPLETE SMOKE DETECTION - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.C)

4. PATIENT CARE NON - SLEEPING SUITES:

A. SINGLE EXIT SUITE - 2,500 SQ. FT. (NFPA 101 - 19.2.5.7.3.1.B)

B. MULTI EXIT SUITE - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.3.3)

5. HEALTH CARE OCCUPANCY NON - PATIENT - CARE SUITES FOLLOW THE TRAVEL DISTANCE

REQUIREMENTS AS LISTED IN TABLE A.7.6 OF NFPA 101.

6. SUITES IN OTHER OCCUPANCIES ARE NOT REGULATED IN SIZE BUT STILL FOLLOW THE TRAVEL

DISTANCE REQUIREMENTS AS LISTED IN TABLE A.7.6 OF NFPA 101.

FIRE ALARM SYSTEM:

1. THE FIRE ALARM SYSTEM WAS DESIGNED TO OLDER EDITION OF NFPA 72,

NATIONAL FIRE ALARM CODE.

2. PRIVATE MODE BUILDING OCCUPANT NOTIFICATION IS INSTALLED PER

SECTIONS 19.3.4.3.1 AND 9.6.3.6.3 OF NFPA 101-2012 EDITION.

3. PRIVATE MODE AUDIBLE DEVICES (SPEAKERS) ARE INSTALLED IN

CORRIDORS AND LARGER ROOMS OR SUITES PER SECTION 18.4.4.1 OF

NFPA 72- 2010 EDITION.

4. PRIVATE MODE VISIBLE DEVICES (STROBES) ARE INSTALLED AT

REDUCED QUANTITY AND SPACING PER SECTION 18.6 OF THE NFPA 72-

2010 EDITION.

5. STROBE CIRCUITS ARE REQUIRED TO BE SYNCHRONIZED IN

ACCORDANCE WITH SECTION 18.5.4.3.2(3) OF NFPA 72-2010 EDITION.

6. TYPICAL SMOKE DETECTORS HAVE A 21 FT. RADIUS OF COVERAGE AREA

(NFPA 72- 17.7.3.2.3.1)

7. SMOKE DETECTORS THAT ARE CONNECTED TO THE BUILDING FIRE

ALARM SYSTEM AND LOCATED ON BOTH SIDES OF SMOKE/FIRE DOORS

MAY BE SPACED AT MAXIMUM 21' RADIUS FOR DOOR RELEASE SERVICE

(NFPA 72- 17.7.5.6.1) SMOKE DETECTORS NOT CONNECTED TO THE

BUILDING FIRE ALARM SYSTEM AND USED EXCLUSIVELY FOR SMOKE/FIRE

DOOR RELEASE SHALL BE LOCATED AND SPACED PER NFPA 72- 17.7.5.6.

8. CEILINGS WITH BEAM DEPTHS OF LESS THAN 10% OF CEILING HEIGHT

SHALL BE CONSIDERED A SMOOTH CEILING FOR SMOKE DETECTOR

COVERAGE. CEILINGS WITH BEAM DEPTHS GREATER THAN 10% OF

CEILING HEIGHT SHALL HAVE REDUCED SMOKE DETECTOR SPACING

COVERAGE (NFPA 72- 17.7.3.2.4.2).

9. SMOKE DETECTORS SHALL BE LOCATED ON THE CEILINGS THE BOTTOM

OF BEAMS OR MAXIMUM 12" DOWN FROM THE CEILING TO TOP OF THE

DETECTOR (NFPA 72- 17.7.3.2.1).

10. SMOKE DETECTORS SHALL NOT BE LOCATED DIRECTLY IN THE AIR

STREAM OF SUPPLY AIR REGISTERS (NFPA 72- 17.7.6.3.2).

OCCUPANCY TABLE

THE VA HAS ELECTIVE ACCREDITATION WITH THE JOINT COMMISSION (TJC) FOR HEALTH CARE FACILITIES. SEE THE MEMORANDUM OF UNDERSTANDING (EFFECTIVE 4 SEPTEMBER, 2017) BETWEEN THE VA AND TJC FOR

IMPLEMENTATION OF TJC ENVIRONMENT OF CARE (EC) AND LIFE SAFETY (LS) STANDARDS.

THE VA HAS ELECTIVE ACCREDITATION WITH THE LONG-TERM CARE INSTITUTE, INC. (LTCI) FOR COMMUNITY LIVING CENTERS (CLC). SEE THE CLARIFICATION MEMORANDUM (EFFECTIVE MARCH 29, BETWEEN THE VA AND THE

LTCI FOR IMPLEMENTATION OF LIFE SAFETY REQUIREMENTS.

THE FOLLOWING NATIONWIDE VA EQUIVALENCIES HAVE BEEN REVIEWED AND APPROVED BY THE JOINT

COMMISSION AND APPLY TO ALL BUILDINGS:

1. OVERSIZED PROTECTIVE PLATES PERMITTED ON FIRE RATED DOORS

2. BUSINESS OCCUPANCY DEAD END CORRIDORS PERMITTED TO EXCEED 50 FEET

EQUIVALENCIES

Building No. Floor Health Care Ambulatory Health

Care Business Industrial Dormitory Total 1 11 0 0 0 1,250 0 1,250

1 10 0 0 0 4,660 0 4,660

1 9 0 0 15,118 2,113 0 17,231

1 8 62,672 0 0 855 0 63,527

1 7 40,538 10,553 29,778 0 0 80,869

1 6 69,617 0 10,329 0 0 79,946

1 5 31,976 0 10,272 45,750 0 87,998

1 4 88,186 0 22,514 0 0 110,700

1 3 0 0 75,322 30,661 0 105,983

1 2 0 40,848 78,482 0 0 119,330

1 1 0 53,379 58,737 0 0 112,116

1 Basement 0 11,378 153,089 10,495 0 174,962

1 Sub-Basement 0 0 0 15,481 0 15,481

TOTAL 292,989 116,158 453,641 111,265 0 974,053

1. EXITS (STAIRWAYS, HORIZONTAL EXITS AND DIRECT EXTERIOR EXIT DOORS), OTHER THAN EXTERIOR EXIT DOORS THAT ARE OBVIOUSLY AND CLEARLY IDENTIFIABLE AS EXITS. (GLASS DOORS, VISION PANELS OR ADJACENT WINDOWS) SHALL BE MARKED WITH EXIT SIGNAGE. (SECTION 7.10.1.2.1 OF NFPA 101-2018 EDITION)

2. DIRECTIONAL SIGNS REQUIRED WHERE DIRECTION OF TRAVEL IS NOT APPARENT IN AN EXIT ACCESS

CORRIDOR. (SECTION 7.10.2.1 OF NFPA 101-2018 EDITION)

3. DIRECTIONAL SIGNAGE (EXIT PLACARDS) REQUIRED WITHIN HORIZONTAL COMPONENTS OF EXIT STAIR ENCLOSURES WHERE EGRESS PATH IS NOT OBVIOUS (SECTIONS 7.10.2.2 AND 7.10.1.2.2 OF NFPA 101-2018

EDITION)

4. MAXIMUM VIEWING DISTANCE TO AN EXIT SIGN IN AN EXIT ACCESS CORRIDOR IS 100 FT. (SECTION 7.10.1.5.2 OF

NFPA 101-2018 EDITION)

5. EXIT SIGNS SHALL BE INSPECTED MONTHLY. (SECTION 7.10.9.1 IF NFPA 101-2018 EDITION)

6. DIRECTIONAL SIGNAGE (EXIT PLACARDS OR EXIT SIGNS) WITH OR WITHOUT DIRECTIONAL ARROWS SHOULD BE

PROVIDED IN SUITES USED BY THE GENERAL PUBLIC (LESS THAN 50 TOTAL OCCUPANTS) TO DIRECT THE GENERAL PUBLIC BACK TO THE WAITING AREA. (SECTION 7.10.2.1 OF NFPA 101-2018 EDITION)

7. ROOMS OR SUITES OF ROOMS USED FOR 50 OCCUPANTS OR MORE SHALL BE PROVIDED WITH EXIT SIGNAGE.

(SECTIONS 13.2.10.1 AND 3.3.196.2 OF NFPA 101-2018 EDITION)

EXIT SIGN REQUIREMENTS

DATEREVISIONS: NUMBER

DRAFT SOC

FP&C Project Number Project NumberProject Title

Location

Issue Date Checked by Drawn by

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE

FVO KW Dwg. of

1557.31

INDIANAPOLIS, IN

UPDATE STATEMENT OF

CONDITIONS

RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC

1481 W. 10th Street Indianapolis, IN 46202

VA PLANNING AND ENGINEERING X-2

583-19-506

1/15/2021 6/1/20

STATEMENT OF CONDITIONS

WALL DESCRIPTIONS

COVER PAGE

FINAL SOC 9/16/20

DRAFT OUTER BUILDINGS 10/05/20

DRAFT OUTER BUILDINGS 2 12/18/20

P

IP

E B

A S

E M

E N

T

CHASE

C-SB4

SIGNAL

VAULT

ELECTRICAL

VAULT

SUB-BASEMENT

C-SB1

R O

O M

C -S

B

UP

PIPE BASEMENT

UP

UP

STEAM VAULT

TUNNEL

MECHANICAL

UTILITY CRAWL

SPACE

DIETARY

ELEV. PIT

ELEV. PIT

MECHANICAL STORAGE

SUB-BASEMENT

CHASE

CHASE

STAIR #12-SB

STAIR #7-SB

SPACE

UTILITY CRAWL

UTILITY CRAWL

SPACE SPACE

SPACE

UTILITY CRAWL

CRAWL

UTILITY

SPACE SPACE SPACE

SPACE

UTILITY CRAWL

SPACE

SPACE

UTILITY CRAWL SPACE

SPACE

SPACE

UTILITY CRAWL

SPACE

UTILITY CRAWL

UTILITY CRAWL

UTILITY

CRAWL

UTILITY

SPACE

UTILITY CRAWL

SPACE

SPACE

UTILITY CRAWL

CRAWL

UTILITY

SPACE

CRAWL

SPACE

SPACE

UTILITY CRAWL

SPACE

UTILITY CRAWL

SERVICE ROOM

SPACE

CHASE

C-SB3

M E

C H

A N

IC

A

L

DUMBWAITER PIT

DUMBWAITER PIT

ELEV. PIT

ELEV. PIT

ELEV.

PIT

MECH. ROOM FLOOR

VERTICAL

LIFT

MEDICAL RECORD FILES

UP

STAIR #1-SB

& RADIOLOGY

UTILITY CRAWL

UNEXCAVATED

SUB-BASEMENT

ELEVATOR PIT

CHASE

CHASE

CHASE

ELEVATOR PIT

C H

A S

E

STAIR

STAIR #14-SB

STAIR #8-SB

STAIR #9

STAIR

THIS AREA SHOWN FOR REFERENCE ONLY

SEE BASEMENT FLOOR PLAN

SPACE

UTILITY CRAWL

SPACE

UTILITY CRAWL

UTILITY CRAWL

SPACE

UTILITY CRAWL

CRAWL

UTILITY

CRAWL

UTILITY

UTILITY CRAWL UTILITY CRAWL

UTILITY CRAWL

UTILITY CRAWL

SPACE

SPACE

UTILITY CRAWL

SPACE

UTILITY CRAWL

SPACE

UTILITY CRAWL

SPACESPACE

UTILITY CRAWL

CRAWL

SPACE SPACE

CRAWL

UTILITY

SPACE

SPACE

UTILITY CRAWL

UTILITY CRAWL

SPACE

UTILITY CRAWL

UTILITY CRAWL

SPACE

UTILITY

UTILITY CRAWL

SPACE

INDUSTRIAL OCCUPANCY

ZONE 1ISB-01

AREA B

AREA C

AR

EA

A

AR

EA

C

AREA B

AREA A

1190 SQ FT

INDUSTRIAL OCCUPANCY

ZONE 1ISB-02

1138 SQ FT

INDUSTRIAL OCCUPANCY

ZONE 1ISB-03

2757 SQ FT

INDUSTRIAL OCCUPANCY

ZONE 1ISB-04

10217 SQ FT

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

DATEREVISIONS: NUMBER

DRAFT SOC

FP&C Project Number Project NumberProject Title

Location

Issue Date Checked by Drawn by

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE

FVO KW 36Dwg. of

1557.31

EP

LC

TC

EX

HE

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

INDIANAPOLIS, IN

UPDATE STATEMENT OF

CONDITIONS

RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC

1481 W. 10th Street Indianapolis, IN 46202

SPRINKLER / FIRE SMOKE ZONE

VA PLANNING AND ENGINEERING

SUB BASEMENT FLOOR

BUILDING 1

STATEMENT OF CONDITIONS

1SOC-SB

583-19-506

NON-RATED SMOKE PARTITION

1/15/2021 6/1/20

APPROVED EQUIVALENCIES

1. MINI-ATRIUM EQUIVALENCY DATED 12-14-10

2. NON-LISTED URETHANE FOAM IN WALLS THAT ARE NOT FIRE OR SMOKE

BARRIER WALLS EQUIVALENCY DATED 8-26-09

3. BUILDING 7, CSR SINGLE MEANS OF EGRESS EQUIVALENCY DATED 13-7-07

4. NON-SPRINKLERED ELEVATOR MACHINE ROOM EQUIVALENCY DATED

12-27-04

5. NO VENTING OF LINEN CHUTES EQUIVALENCY DATED 5-29-96

6. NON-COMPLIANT PROTECTIVE PLATES EQUIVALENCY DATED 4-21-95

7. PASS-THROUGH CABINETS EQUIVALENCY DATED 3-15-94

8. TRAVEL DISTANCE AND COMMON PATH OF TRAVEL DISTANCES ARE

EXCEEDED.

-BASEMENT ZONE 11B-06 EQUIVALENCY DATED 9-6-12

FINAL SOC 9/16/20

DRAFT OUTER BUILDINGS 10/05/20

DRAFT OUTER BUILDINGS 2 12/18/20

1/15/21 UPDATED FINAL SOC

COMPOSITE

FULLY SPRINKLERED

INDUSTRIAL OCCUPANCY

N

BUILDING 1 SUB BASEMENT

P

IP

E B

A S

E M

E N

T

CHASE

C-SB4

SIGNAL

VAULT

ELECTRICAL

VAULT

SUB-BASEMENT

C-SB1

R O

O M

C -S

B

UP

UP

STEAM VAULT

TUNNEL

MECHANICAL

UTILITY CRAWL

SPACE

DIETARY

SUB-BASEMENT

STAIR #12-SB

SPACE

SPACE

UTILITY CRAWL

SPACE

UTILITY CRAWL

SPACE

SPACE

UTILITY CRAWL

CRAWL

UTILITY

SPACE

CRAWL

SPACE

SPACE

UTILITY CRAWL

SPACE

UTILITY CRAWL

SERVICE ROOM

CHASE

C-SB3

M E

C H

A N

IC

A

L

DUMBWAITER PIT

DUMBWAITER PIT

ELEV. PIT

ELEV. PIT

ELEV.

PIT

MECH. ROOM FLOOR

VERTICAL

LIFT

UNEXCAVATED

CHASE

CHASE

CHASE

ELEVATOR PIT

C H

A S

E

STAIR

STAIR #14-SB

STAIR #9

STAIR

UTILITY CRAWL

SPACE

UTILITY CRAWL

UTILITY CRAWL

SPACE

UTILITY CRAWL

UTILITY CRAWL

SPACE

UTILITY

UTILITY CRAWL

SPACE

AR

EA

A

AR

EA

C

AREA B

AREA A

INDUSTRIAL OCCUPANCY

ZONE 1ISB-02

1138 SQ FT

INDUSTRIAL OCCUPANCY

ZONE 1ISB-03

2757 SQ FT

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

DATEREVISIONS: NUMBER

DRAFT SOC

FP&C Project Number Project NumberProject Title

Location

Issue Date Checked by Drawn by

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE

FVO KW 36Dwg. of

1557.31

EP

LC

TC

EX

HE

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

INDIANAPOLIS, IN

UPDATE STATEMENT OF

CONDITIONS

RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC

1481 W. 10th Street Indianapolis, IN 46202

SPRINKLER / FIRE SMOKE ZONE

VA PLANNING AND ENGINEERING

SUB BASEMENT FLOOR

BUILDING 1

STATEMENT OF CONDITIONS

1-SOCSBA

583-19-506

NON-RATED SMOKE PARTITION

1/15/2021 6/1/20

APPROVED EQUIVALENCIES

1. MINI-ATRIUM EQUIVALENCY DATED 12-14-10

2. NON-LISTED URETHANE FOAM IN WALLS THAT ARE NOT FIRE OR SMOKE

BARRIER WALLS EQUIVALENCY DATED 8-26-09

3. BUILDING 7, CSR SINGLE MEANS OF EGRESS EQUIVALENCY DATED 13-7-07

4. NON-SPRINKLERED ELEVATOR MACHINE ROOM EQUIVALENCY DATED

12-27-04

5. NO VENTING OF LINEN CHUTES EQUIVALENCY DATED 5-29-96

6. NON-COMPLIANT PROTECTIVE PLATES EQUIVALENCY DATED 4-21-95

7. PASS-THROUGH CABINETS EQUIVALENCY DATED 3-15-94

8. TRAVEL DISTANCE AND COMMON PATH OF TRAVEL DISTANCES ARE

EXCEEDED.

-BASEMENT ZONE 11B-06 EQUIVALENCY DATED 9-6-12

FINAL SOC 9/16/20

DRAFT OUTER BUILDINGS 10/05/20

DRAFT OUTER BUILDINGS 2 12/18/20

1/15/21 UPDATED FINAL SOC

AREA - A

FULLY SPRINKLERED

INDUSTRIAL OCCUPANCY

N

ELEV. PIT

ELEV. PIT

MECHANICAL STORAGE

STAIR #7-SB

UTILITY

CRAWL

UTILITY

UP

SUB-BASEMENT

STAIR #8-SB

CRAWL CRAWL

UTILITY

AREA B

AREA C

INDUSTRIAL OCCUPANCY

ZONE 1ISB-04

10217 SQ FT

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

DATEREVISIONS: NUMBER

DRAFT SOC

FP&C Project Number Project NumberProject Title

Location

Issue Date Checked by Drawn by

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE

FVO KW 36Dwg. of

1557.31

EP

LC

TC

EX

HE

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

INDIANAPOLIS, IN

UPDATE STATEMENT OF

CONDITIONS

RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC

1481 W. 10th Street Indianapolis, IN 46202

SPRINKLER / FIRE SMOKE ZONE

VA PLANNING AND ENGINEERING

SUB BASEMENT FLOOR

BUILDING 1

STATEMENT OF CONDITIONS

1SOC-SBB

583-19-506

NON-RATED SMOKE PARTITION

1/15/2021 6/1/20

APPROVED EQUIVALENCIES

1. MINI-ATRIUM EQUIVALENCY DATED 12-14-10

2. NON-LISTED URETHANE FOAM IN WALLS THAT ARE NOT FIRE OR SMOKE

BARRIER WALLS EQUIVALENCY DATED 8-26-09

3. BUILDING 7, CSR SINGLE MEANS OF EGRESS EQUIVALENCY DATED 13-7-07

4. NON-SPRINKLERED ELEVATOR MACHINE ROOM EQUIVALENCY DATED

12-27-04

5. NO VENTING OF LINEN CHUTES EQUIVALENCY DATED 5-29-96

6. NON-COMPLIANT PROTECTIVE PLATES EQUIVALENCY DATED 4-21-95

7. PASS-THROUGH CABINETS EQUIVALENCY DATED 3-15-94

8. TRAVEL DISTANCE AND COMMON PATH OF TRAVEL DISTANCES ARE

EXCEEDED.

-BASEMENT ZONE 11B-06 EQUIVALENCY DATED 9-6-12

FINAL SOC 9/16/20

DRAFT OUTER BUILDINGS 10/05/20

DRAFT OUTER BUILDINGS 2 12/18/20

1/15/21 UPDATED FINAL SOC

AREA - B

FULLY SPRINKLERED

INDUSTRIAL OCCUPANCY

N

C-SB4

SIGNAL

VAULT

ELECTRICAL

VAULT

SUB-BASEMENT

C-SB1

R O

O M

C -S

B

PIPE BASEMENT

UP

DIETARY

CHASE

CHASE

SPACE

UTILITY CRAWL

UTILITY CRAWL

SPACE SPACE

SPACE

UTILITY CRAWL

CRAWL

UTILITY

SPACE SPACE SPACE

SPACE

UTILITY CRAWL

SPACE

SPACE

UTILITY CRAWL SPACE

SPACE

SPACE

UTILITY CRAWL

SPACE

UTILITY CRAWL

UTILITY CRAWL

UTILITY

CRAWL

UTILITY

SERVICE ROOM

SPACE

C-SB3

M E

C H

A N

IC

A

L

VERTICAL

LIFT

MEDICAL RECORD FILES

STAIR #1-SB

& RADIOLOGY

UTILITY CRAWL

UNEXCAVATED

ELEVATOR PIT

STAIR #14-SB

STAIR #8-SB

THIS AREA SHOWN FOR REFERENCE ONLY

SEE BASEMENT FLOOR PLAN

SPACE

UTILITY CRAWL

SPACE

UTILITY CRAWL

UTILITY CRAWL

SPACE

UTILITY CRAWL

CRAWL

UTILITY

CRAWL

UTILITY

UTILITY CRAWL UTILITY CRAWL

UTILITY CRAWL

UTILITY CRAWL

SPACE

SPACE

UTILITY CRAWL

SPACE

UTILITY CRAWL

SPACE

UTILITY CRAWL

SPACESPACE

UTILITY CRAWL

CRAWL

SPACE SPACE

CRAWL

UTILITY

SPACE

INDUSTRIAL OCCUPANCY

ZONE 1ISB-01

AREA B

AREA C

1190 SQ FT

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

DATEREVISIONS: NUMBER

DRAFT SOC

FP&C Project Number Project NumberProject Title

Location

Issue Date Checked by Drawn by

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE

FVO KW 36Dwg. of

1557.31

EP

LC

TC

EX

HE

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

INDIANAPOLIS, IN

UPDATE STATEMENT OF

CONDITIONS

RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC

1481 W. 10th Street Indianapolis, IN 46202

SPRINKLER / FIRE SMOKE ZONE

VA PLANNING AND ENGINEERING

SUB BASEMENT FLOOR

BUILDING 1

STATEMENT OF CONDITIONS

1SOC-SBC

583-19-506

NON-RATED SMOKE PARTITION

1/15/2021 6/1/20

APPROVED EQUIVALENCIES

1. MINI-ATRIUM EQUIVALENCY DATED 12-14-10

2. NON-LISTED URETHANE FOAM IN WALLS THAT ARE NOT FIRE OR SMOKE

BARRIER WALLS EQUIVALENCY DATED 8-26-09

3. BUILDING 7, CSR SINGLE MEANS OF EGRESS EQUIVALENCY DATED 13-7-07

4. NON-SPRINKLERED ELEVATOR MACHINE ROOM EQUIVALENCY DATED

12-27-04

5. NO VENTING OF LINEN CHUTES EQUIVALENCY DATED 5-29-96

6. NON-COMPLIANT PROTECTIVE PLATES EQUIVALENCY DATED 4-21-95

7. PASS-THROUGH CABINETS EQUIVALENCY DATED 3-15-94

8. TRAVEL DISTANCE AND COMMON PATH OF TRAVEL DISTANCES ARE

EXCEEDED.

-BASEMENT ZONE 11B-06 EQUIVALENCY DATED 9-6-12

FINAL SOC 9/16/20

DRAFT OUTER BUILDINGS 10/05/20

DRAFT OUTER BUILDINGS 2 12/18/20

1/15/21 UPDATED FINAL SOC

AREA - C

FULLY SPRINKLERED

INDUSTRIAL OCCUPANCY

N

EX

G-1

ELEV. CHASE

DN

UP

UP

UP

UP

WATER SOFTENER

A-B110

WASH

A-B109A

REPAIR

LOBBY

A-B114

SHOP

A-B115

CB-3

CARPENTER

SHOP

A-B121

A-B116 A-B120

A-B108A

A-B117

SUPER-

A-B118 A-B119

OFFICE

A-B040

A-B043

A-B021

TRAINING

C O

R R

ID

O

R

SEC./

A- B0

OFFICE

A-B136

REPAIR ENG.

A-B142 A-B143

A-B148

ROOM

B-B033 B-B045

ROOM

RECEPT.

OFFICE

ROOM

UTILITY

B-B041

OFFICE

B-B036

C O

N

TR

O L

R O

O M

B-B038 ROOM

B-B015

A-B137

C-B067

ROOM

C-B129

STORAGE

C B-

C-B030

MACHINE SHOP

C-B033

C-B075

C-B118 C-B120

C-B091

TOILET

C -B

C-B113A

C-B117A C-B102

WOMEN

C-B103 C-B109

C-B098 C-B095 C-B094

C O

N

TR

O L

C -B

C O

R R

ID

O

R

C O

R R

ID

O

R

C-B092

STOR.

EL

EC

TR

O

N

IC

S

MANUAL

SHIPPING

CB-52

CORRIDOR

CB-55

CORRIDOR C-B063

FIRE EQUIP.

MAIL

STOR.

MAINT.

ROOM

STAIR #3-B

MECH.

RECEIVING

EQUIP.

AUTOPSY

C-B123

SUITE

C O

R R

ID

O

R

C B-

C

O R

R

ID

O R

R.O. EQUIPMENT

CHIEF

COOLER #1

WALK-IN

C-B145CANTEEN

FREEZER 4

ELEV.

A-B154

R

AM

P U

P

UP

#1-B

S-5

TELE. ROOM

P-4 S-6

P-10

LOBBY

D-B009

#7-B

FIRE PUMP

MECHANICAL

ROOM

C -B

C O

R R

ID

O

R

LOBBY

EXERCISE

C B-

MEN

LOCKERS

C-B006

CHUTE

C-B004

LINEN

MECH.

C -B

LOBBY

C-B027

RADIATION

OFFICE

MECH. ROOM

SUPER-

ELECTRIC

SHOP

A-B145

VISOR

C-B150

C-B153

CB-46

C-B156

CLEAN EQUIP.

SEAMSTRESS

EFFECTS

GOODWILL

FO

R

M

AN

EM

S

G

EN

C H

U

TE

LI

N

EN

STORAGE

C-B191

UP

A-B045

PARTS

STORAGE

C-B032

STORAGE

FLAMMABLE

C -B

LOBBY

VIEWING ROOM

C-B119

BIOMEDICAL

CORRIDOR

C-B071

SVCS.

ENG.

ELEV.

S-11

S-12

ELEV.

P-15

DOCK

LOADING

STAIR #6-B

C-B115

CORRIDOR

C-B019

MEN

STORAGE

UP

UP

STORAGE

A-B138

ELECTRICAL

C-B157

DN

CORRIDOR

FIRE

EL

EV

AT

O

R

CHASE

ELEV.

ELEV.ELEV. ELEV. ELEV.

AR

EA

AREA

AREA

AREA

FREIGHT

GENERATOR

SUBSTATION

ST

O

R

AG

E

SWITCH GEAR

MAINTEN-

ANCE

MAINTEN-

VISOR

SUPER-

FUTURE

ENVIRO.

ROOM

ELEC.

AR

EA

W

AY

S

CHASE

ROOM

C O

O R

ID

O

R

CHUTE

LIFT

SH

AF

T

SHAFT

SH

AF

T

SH

AF

T

"E

"F

"H

SHAFT

M

EC

H

CB-38

RAMP UP

STAIR

A-B123

E-B004

UP

B- B0

B-B043

OFFICE

WAITING

OF QM

255 SQ.FT.

C-1

TOILET

BREAKOUT

A-B081

SHOP

MASONRY

A-B102

CLOSET

CLOSET

A-B104

CLOSET

A-B105

AC SHOP

A-B106

STORAGE

CLERKS

CORRIDOR

CB-7

LOUNGE

A-B071

A-B072

LIFT

CORRIDOR

CB-30

LI

FT LIFT

ELEC.

A-B075

AREA

SUPPLY STORAGE

PLUMBING

ASST.

CHIEF

A-B087

TOILET

WOMEN

A-B084

A-B078

SHOP

SPS STORAGE

STORAGE

A-B080

DECON

A-B067

PREPARATION/

ROOM

A-B062

SCOPE

ETO

ASST. LOG

A-B048

ENVIRONMENTAL

TOILET

FOR QCIS

C-B188

P-1

DN

O

FF

IC

E

C-B062

C-B055

HELP

UP

DN

UP

D-B010

ROOM

GENERATOR

UP

FOREMAN

EMS

C-B192

SERVICES

C-B185

RECEIVING

DN

R

AM

P

IMS

QCIS/QM

A-B033B

SECTION

CODING

ICRA

A-B018b

QM

A-B017b

SC

AN

N

IN

G

HIMS

O

FF

IC

E

ENVIRONMENTAL

UP

UP

A-B113 OUTDOOR

STORAGE

A-B112

AND WASHDOWN

MAINTENANCE

A-B110

WHEELCHAIR

CB-5

PAINT

A-B125

COLLECT.

DUST

LOBBY

ELECTRICAL

PRINTS

BLUE

MACHINE AND

WELDING SHOP

ANCE

MAINTEN-

VISOR

A-B044

R01

A-B043b

CHIEF

LOG SERVICE

A-B030

P&H COPY

A-B135

BED

A-B141

LOCKSMITH

SERVICE

C O

R R

ID

O

R C

B-

ELECTRICAL

SWITCHGEAR

A-B139

MECHANICAL

ELEC.

A-B147

ST

AI

R

-B

C O

R R

ID

O

R C

B-

TELE.

ROOM

B-B051

CORRIDOR

CB-20

EQUIP RM

TE

LE

R

O O

M

CORRIDOR

B- B0

B-B046

CONTROL

B-B034 B-B044

B-B035

MRI

SOILED

B-B042

SCAN ROOM

B- B0

B-B014

ROOM

TREATMENT

CORRIDOR

CB-11

TREATMENT

AREA WELL

B-B022 B-B023

M&O

OFFICE

C-B065

H.A.C.

C-B040

CHUTE

LINEN

C-B039

C-B037

C O

R R

ID

O

R

C -B

4A

SE

C

C-B030A

ENGINEER

BIOMEDICAL

C-B028

C-B035

C -B

C-B127

C -B

C-B034

C-B144

C-B146 C-B149

FREEZER 2

C-B069

GENERATOR

EMERGENCY

C-B115A

C-B118A

C-B112A

C-B110A

C-B114A

C-B097

C-B110

C-B108

C-B107

C-B093C-B096

MISC.

CORRIDOR

EL

EC

TR

O

N

IC

S

SUPPORT

CLERICAL

C O

R R

ID

O

R

C-B170

C-B064

R O

O M

CANTEEN STORAGE

EQUIP.

FIRE

C-B100

SHAFT

C B-

SWITCHGEAR ROOM

C-B074

SERVICE

CANTEEN

C-B072

SERVICE

CANTEEN

C-B073

ELEC.

ROOM

C-B066

OFFICE

STORAGE STORAGE

EMS

A-B151

TE

LE

. R M

C-B031

REPAIR & DEVELOPMENT

C-B077

RECEIVING

C-B076

CLOSET

C-B151

CHASE 1B

A-B150

MECHANICAL ROOM

TE

LE

. R M

TOILET

ELEV.

P-14

P-13

ELEV.

A- B1

TE

LE

PH

O

N E

R O

O M

MEN

P-16

A-B153

ROOM

ELEC.

ELIGIBILITY

ACCOUNTS &

PATIENTS

A-B155

TOILET

R

AM

P U

P

P-3P-2

D-B008

ROOM

GENERATOR

D-B011

D-B001

D-B006

D-B004

STAIR

ROOM

TO

IL

ET

LO

C

KE

R

R O

O M

LOCKERS

C-B010

C B-

A

#2-B

EMPLOYEE

ROOM

C-B008

CORRIDORC

O

R R

ID

O

R

IMS

C-B003

ROOM

C-B203

C-B017

UPS ROOM

OFFICE

C-B016

PI

PE

C H

AS

E

R

AM

P

C-B179

ONCOLOGY

RECEPT.

B-B029 C-B021

SUPER-

ELECTRIC

SHOP

A-B145

VISOR

ELECTRICAL

SWITCHGEAR

A-B140

COMMUNICATIONS ROOM

STAIR

FREEZER 3

C-B152

CONTROL

INGREDIENT

C-B154

OFFICE

C-B155

CORRIDOR CORRIDOR

DISHWASH./

C-B201

C-B200

CLEAN LINEN

C-B196C -B

C -B

4C

LO

SE

T C

-B

OFFICE

C-B187

EQUIP

FIRE

MANAGEMENT

ST

AI

R

-B

MECH.

ROOM

C -B

CLOSET

C-B018

MATERIALS

SUPER-

VISOR

MAINTE-

NANCE

ADMIN.

SUPV.

VO

C

R

EH

AB

C O

M

PU

TE

R

L

AB

FIRE

EQUIP.

C-B012

CB-31

C-B121

VESTIBULE

C-B122

COLD ROOM

ENV. SERV.

C-B124

STORAGE

ENG.

SUPERVISOR

C-B038

CB-2

STORAGE

EQUIP.

ELEV.

SUPPLIES/EQUIPMENT

STORAGE/

A-B001

A-B126

STAIR

ELEV.

ROOM

MECH.

SWITCH GEAR

TOILET

C-B007

DN

DN

ELECTRICAL

SHOP

A-B144

A-B146

CHUTE

LINEN

TOILET

CB-21

CORRIDOR WASH

C-B180

OPEN

D -B

EQUIP.

M

AC

H

IN

E

EQ

U

IP

M

EN

T

CHASE

DN

D-B003

ELECTRICAL

ROOM

P-9 P-8

ELEV.

ELEV.

ELEV.

ELEV.

AR

EA

AREA

AR

EA

AR

EA

ELEVATOR

LOBBY

EMERGENCY

TRAINING

EMS

SUBSTATION

C-B104 C-B105 C-B106

C-B099

ANCE

VISOR

SUPER-

S-13

ELEV.

S-7

C H

AS

E

C H

AS

E

AR

EA

W

AY

S

C-B178

SERVICE

CHASE

C H

AS

E

CHASE

C H

AS

E

CORRIDOR

CB-36

C H

AS

E

TOILET

ROOM

WOMEN

W O

M

EN

B-B028

SHAFT

SH

AF

T

SHAFT

SHAFT

SH

AF

T

SHAFT

"A" "B" "C"

"D

"G

"K" "J"

TO

IL

ET

C H

AS

E

PASSAGE

C O

R R

ID

O

R C

O R

R

ID

O R

C B-

STAIRCASE

STAIRCASE

ROOM

CONFERENCE

SUPV

STAIR

#4-B

ENGINEERING

C-B056

C-B111A

#14-B

STAIR

D R

ES

S.

R M

B- B0

D

R

ES

S.

R

M

BREAK

ROOM

B-B047

PACS & MRI

DCS

A-B034

WAREHOUSE

EB-028

SUPERVISOR

OFFICE

EB-029

C-2

C O

R R

ID

O

R C

B-

MEN

A-B103

CLEAN EQUIP.

A-B082

SPD

A-B085

SUPPLY

A-B074

CORRIDOR

CB-7

WOMEN

TOILETA-B073

TOILET

MEN

A-B070

EQUIPMENT

SUPER-

VISOR

A-B088

EQ

P.

A- B0

A-B089

STORAGE

ROOM

A-B090

STERILE SUPPLY

A-B079

SERVICE

ENVIRO.

WASH

A-B068

LIFT

SHOP

A-B107

CHIEF

CLERK

PLUMBING

A-B108

A-B109

A-B083

RECEPTION

BULK/

CASE CART

EQUIPMENT

STORAGE

EQUIPMENT

A-B069 LO

U

N G

E A-

B0

A-B061

DECONTAMINATION

STERILIZATION

A-B066

ASSEMBLY/

STERILIZATION

A-B065

CART WASH

A-B077

MEN

TOILET

SPD

DECONTAMINATION

A-B063

C H

AS

E

CHIEF, LOG

A-B042

A-B

A-B

WORK

ROOM

SERVICE

CB-9

CORRIDOR

OFFICE

CLERK

A-B156 A-B157

WOMEN

A-B042

A-B041

TEAM

ROOM

ACOS

ELEV.

UP

LO

G

IS

TI

C S

C -B

C-B

C-B058

C-B055

STAIR

DN

DN

C -B

CONF RM

RAMP

A-B050

OFFICE

FOODSERVICE

PROSTHETICS

A-B033d

CODERS

O

FF

IC

E

O

FF

IC

E

A- B0

IMS CLO

E-B002

PE

T

SC

AN

N

ER

CORRIDOR

A-B016

A-B032

ROOM

C O

R R

ID

O

R

A-B023

QM

R01

A- B0 d

A- B0 c

HIMS

CB-17

ELEC. ROOM

A- B0

C

ELECTRICAL

A-B031

WAITING

TR

AN

SC

R

IP

TI

O N

G-2

DW-1

CLOSET

CHASE

STAIR

#12-B

A-B033A

C B-

12 LEAD

O

FF

IC

E

FISCAL

A-B036

FISCAL

A-B038

FISCAL

A-B039

EQUIPMENTA-

B0 a

Q M

A-B017c A-B017a

ST

O

R

ASST CH

HIMS

CHIEF

CONTROL

A-B011B

R

EA

D

IN

G A-

B0

A

C

LE

AN

A-

B0

U

PT

AK

E

A- B0

U

PT

AK

E

A- B0

U

PT

AK

E

A- B0

U

PT

AK

E

A- B0

U

PT

AK

E

A- B0

SOILED

UTILITY CORRIDOR

CB-00A-B004

PET/CT

A-B011C

A-B011D

TOILET

A-B014C

O R

R

ID

O R

C B-

WAITING

A-B002

TOILET

A-B013

R

EC

P.

A-

B0

A

ROOM

A-B003B

WORK

STAFF

TREATMENT

PLANNING

B-B009

B-B010

OFFICE

B-B011

ONCOLOGY

RADIATION

CHIEF

B-B008

CHIEF

PHYSICIST

TOILET

WOMEN

B-B031 B-B030

TOILET

MEN

MANAGER

B-B007

NURSES

B-B005 B-B004

EXAM3 EXAM2

B-B003

EXAM1

B-B002

WAITING ROOM

B-B001

B-B020

TOILET

B-B021

BREAK ROOM

B-B017

HEALTH TECH

B-B016 MECH.

ROOM

B-B018

B-B019

CLOSET

JANITOR

B-B026

B-B012

OFFICE

RESIDENTS'

UTILITY

TOILET

HANDICAP

SH

AF

T

C-B059

OFFICE

NEW CONF.

ROOM

B-B006

B-B024

C O

R R

ID

O

R

CB-3 C

O

R R

ID

O

R

B-B013

ROOM

KLYSTRON

ENG. LOCKSMITH

ENG.

SERVICE

C-B193

GOODWILL

C -B

3A

C-B003BEL

EC

T.

R

O O

M MECH.

ROOM

AUDITORIUM

A-B065A

IMS

C-B001

IMS

C-B002

IMS

OI&T FIBER

OI&T APP DEVP/SUPPORT

CB-25

COMMON

OI&T PC STOR./DEVP.

C-B014

OI&T CS

C-B013

OI&T IS/

C-B202

IMS

OI&T CSU

IMS

WAREHOUSE

IMS

OI&T SUPV

IMS

C-B029

OI&T MGR

C-B030

OI&T ASSIST.

IMS

C -B

OI&T RECP.&

PRINT AREA

C-B025

IMS

OI&T FCIO

C-B026

OI&T SYSTEMS

C-B022

TELECOM

LO

C

KE

R

C-B130

CORRIDOR

C -B

TO

IL

ET

C-B126

C-B174

WOMEN

TOILET

C-B175

CORRIDOR

NON/

FOOD&/

SUPPLY

STOR.

C-B162

C-B164

COOLER

C-B173 C O

R R

ID

O

R

CLOSET

CLEANING

C -B

LIFT

C-3

LOCKER

TO

IL

ET

ST

AF

F

C H

AS

E

HELP DESK

COMPUTER C

-B

C-B158

ROOM

WAITING ROOM

C-B136 C-B137

DIETICIAN

C-B138

MOVE

C-B135

DIETICIAN

C-B176

CAFETERIA

PA

PE

R S

TO

R

AG

E

C-B134C-B133

C-B132 C-B131

C-B163

OFFICE OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

ROOM

IMS

FOOD

SERVICE

FOREMEN

C-B142

SUPPLY

C-B143 H.A.C.

C-B141

C B-

CB-26

CORRIDOR

A-B064

STERILIZATION

ETO

SEC

C-B024

O I&

T

OI&T

A-B043

CHIEF

111 SEATS

UP

PR

O

ST

H

ET

IC

S

PROSTHETIC

S

C-B117

D -B

C -B

7A

OFFICE

EDU SVC.OFFICE

EDU SVC.

OFFICE

EDU SVC.OFFICE

EDU SVC.

OFFICE

EDU SVC.

OFFICE

EDU SVC.

STORAGE

OFFICE

EDU SVC.

OFFICE

EDU SVC.

OFFICE

EDU SVC.

OFFICE

EDU SVC.

OFFICE

EDU SVC.

OFFICE

EDU SVC.

OFFICE

EDU SVC.

EDU SVC.

EDU SVC.

SAFETY

MGR.

ADMIN

SAFETY

RADIATION

S.O.

E.M.S.

INDUSTRIAL

HYGIENIST

STORAGE

CANTEEN

DISTRIBUTION

C -B

3A

BREAK ROOM

EB030

C -B

8A

O

FF

IC

E

PR

O

ST

H

ET

IC

S

OFFICE

EB-029A

GIP

COMMMECH

ROOM

A-B025 A-B024

A-B037

OFFICE

A-B101A-B100

A- B1

A-B159

CB-22

LOBBY

CORRIDOR

C B-

C B-

C -3

ROOM

C-1

SPD

C O

R R

ID

O

R C

B-

CB-10

LOBBY

CB-11

LOBBY

CB-41

C-B014A

OI&T TURN-IN

C-B148

C-B159

C-B125

D-B001

OF SRD

QM

CT ROOM

OFFICE

CONTROL RM.

SHAFT

SOILED

EXAM 5

B-B024

EXAM 4

EB-C02

EB-026

EB-028

EB-027

B- B0

A

D R

ES

S.

R M

DR. B-B027

FCIO

DIETITIAN

WAN TEAM

ELEC. EQUIP.

ROOM

COOR

W O

M

EN

CART

OI&T IT STOR

#8-B

#5-B

STAIR

#14-B

MAIN WAREHOUSE

LOGISTICS

LOGISTICS

LOGISTICS

LO

GISTIC

S

LO

GISTIC

S

TRAINING

BLOCK

ROOM

LEAD

WALLS

B-B025

SIMULATOR

BUSINESS AND OTHER USES

10893 SQ FT

BUSINESS AND OTHER USES

ZONE 1IB-02

16267 SQ FT

BUSINESS AND OTHER USES

ZONE 1IB-11

14126 SQ FT

STORAGE OCCUPANCY

ZONE 1IB-01

5996 SQ FT

BUSINESS AND OTHER USES

ZONE 1IB-12

5341 SQ FT

BUSINESS AND OTHER USES

ZONE 1IB-03

13214 SQ FT

AMBULATORY HEALTH CARE

ZONE 1IB-07

5950 SQ FT

BUSINESS AND OTHER USES

ZONE 1IB-08

10541 SQ FT

INDUSTRIAL OCCUPANCY

ZONE 1IB-05

22021 SQ FT

BUSINESS AND OTHER USES

ZONE 1IB-04

22013 SQ FT

BUSINESS AND OTHER USES

ZONE 1IB-03

18009 SQ FT

ZONE 1IB-06

15781 SQ FT

BUSINESS AND OTHER USES

ZONE 1IB-09

18200 SQ FT

BUSINESS AND OTHER USES

ZONE 1IB-10

AR

EA B

AR

EA A

AREA B

AREA A

EP

UNDER

RENOVATION

LC

LC

LC

LC

TC

EX

STAIR #9-B

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

FACP

TOILET

A-B012

FACP

U N

D

ER

C O

N

STR

U C

TIO

N

FHV

STORAGE

OCCUPANCY

BUSINESS

OCCUPANCY

SUITE DESCRIPTIONS

SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

DATEREVISIONS: NUMBER

DRAFT SOC

FP&C Project Number Project NumberProject Title

Location

Issue Date Checked by Drawn by

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE

FVO KW 36Dwg. of

1557.31

EP

LC

TC

EX

HE

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

INDIANAPOLIS, IN

UPDATE STATEMENT OF

CONDITIONS

RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC

1481 W. 10th Street Indianapolis, IN 46202

SPRINKLER / FIRE SMOKE ZONE

VA PLANNING AND ENGINEERING

BASEMENT FLOOR

BUILDING 1

STATEMENT OF CONDITIONS

1SOC-B

583-19-506

NON-RATED SMOKE PARTITION

1/15/2021 6/1/20

APPROVED EQUIVALENCIES

1. MINI-ATRIUM EQUIVALENCY DATED 12-14-10

2. NON-LISTED URETHANE FOAM IN WALLS THAT ARE NOT FIRE OR SMOKE

BARRIER WALLS EQUIVALENCY DATED 8-26-09

3. BUILDING 7, CSR SINGLE MEANS OF EGRESS EQUIVALENCY DATED 13-7-07

4. NON-SPRINKLERED ELEVATOR MACHINE ROOM EQUIVALENCY DATED

12-27-04

5. NO VENTING OF LINEN CHUTES EQUIVALENCY DATED 5-29-96

6. NON-COMPLIANT PROTECTIVE PLATES EQUIVALENCY DATED 4-21-95

7. PASS-THROUGH CABINETS EQUIVALENCY DATED 3-15-94

8. TRAVEL DISTANCE AND COMMON PATH OF TRAVEL DISTANCES ARE

EXCEEDED.

-BASEMENT ZONE 11B-06 EQUIVALENCY DATED 9-6-12

FINAL SOC 9/16/20

DRAFT OUTER BUILDINGS 10/05/20

DRAFT OUTER BUILDINGS 2 12/18/20

1/15/21 UPDATED FINAL SOC

COMPOSITE

FULLY SPRINKLERED

MIXED OCCUPANCY

N

BUILDING 1 BASEMENT

KEY NOTES:

G-1

ELEV. CHASE

DN

UP

UP

UP

UP

WATER SOFTENER

A-B110

WASH

A-B109A

REPAIR

LOBBY

A-B114

SHOP

A-B115

CB-3

CARPENTER

SHOP

A-B121

A-B116 A-B120

A-B108A

A-B117

SUPER-

A-B118 A-B119

OFFICE

A-B040

A-B043

A-B021

TRAINING

C O

R R

ID

O

R

SEC./

A- B0

OFFICE

A-B136

REPAIR ENG.

A-B142 A-B143

A-B148

ROOM

B-B033 B-B045

ROOM

RECEPT.

OFFICE

ROOM

UTILITY

B-B041

OFFICE

B-B036

C O

N

TR

O L

R O

O M

B-B038 ROOM

B-B015

A-B137

C-B067

ROOM

C-B129

STORAGE

C B-

C-B030

MACHINE SHOP

C-B033

C-B075

C-B118 C-B120

C-B091

TOILET

C -B

C-B113A

C-B117A C-B102

WOMEN

C-B103 C-B109

C-B098 C-B095 C-B094

C O

N

TR

O L

C -B

C O

R R

ID

O

R

C O

R R

ID

O

R

C-B092

STOR.

EL

EC

TR

O

N

IC

S

MANUAL

SHIPPING

CB-52

CORRIDOR

CB-55

CORRIDOR C-B063

FIRE EQUIP.

MAIL

STOR.

MAINT.

ROOM

STAIR #3-B

MECH.

RECEIVING

EQUIP.

AUTOPSY

C-B123

SUITE

C O

R R

ID

O

R

C B-

C

O R

R

ID

O R

R.O. EQUIPMENT

CHIEF

COOLER #1

WALK-IN

C-B145CANTEEN

FREEZER 4

ELEV.

A-B154

R

AM

P U

P

UP

C-B027

RADIATION

OFFICE

SUPER-

ELECTRIC

SHOP

A-B145

VISOR

C-B150

C-B153

A-B045

PARTS

STORAGE

C-B032

STORAGE

FLAMMABLE

LOBBY

VIEWING ROOM

C-B119

BIOMEDICAL

CORRIDOR

C-B071

SVCS.

ENG.

ELEV.

S-11

S-12

ELEV.

P-15

DOCK

LOADING

STAIR #6-B

C-B115

CORRIDOR

STORAGE

A-B138

ELECTRICAL

DN

FIRE

MAINTEN-

ANCE

MAINTEN-

VISOR

SUPER-

FUTURE

CHASE

ROOM

SHAFT

M

EC

H

RAMP UP

A-B123

B- B0

B-B043

OFFICE

WAITING

OF QM

C-1

TOILET

BREAKOUT

A-B081

SHOP

MASONRY

A-B102

CLOSET

CLOSET

A-B104

CLOSET

A-B105

AC SHOP

A-B106

STORAGE

CLERKS

CORRIDOR

CB-7

LOUNGE

A-B071

A-B072

LIFT

CORRIDOR

CB-30

LI

FT LIFT

ELEC.

A-B075

AREA

SUPPLY STORAGE

PLUMBING

ASST.

CHIEF

A-B087

TOILET

WOMEN

A-B084

A-B078

SHOP

SPS STORAGE

STORAGE

A-B080

DECON

A-B067

PREPARATION/

ROOM

A-B062

SCOPE

ETO

ASST. LOG

A-B048

ENVIRONMENTAL

TOILET

FOR QCIS

P-1

DN

O

FF

IC

E

C-B062

C-B055

HELP

UP

DN

DN

R

AM

P

IMS

QCIS/QM

A-B033B

SECTION

CODING

ICRA

A-B018b

QM

A-B017b

SC

AN

N

IN

G

HIMS

O

FF

IC

E

UP

UP

A-B113 OUTDOOR

STORAGE

A-B112

AND WASHDOWN

MAINTENANCE

A-B110

WHEELCHAIR

CB-5

PAINT

A-B125

COLLECT.

DUST

LOBBY

ELECTRICAL

PRINTS

BLUE

MACHINE AND

WELDING SHOP

ANCE

MAINTEN-

VISOR

A-B044

R01

A-B043b

CHIEF

LOG SERVICE

A-B030

P&H COPY

A-B135

BED

A-B141

LOCKSMITH

SERVICE

C O

R R

ID

O

R C

B-

ELECTRICAL

SWITCHGEAR

A-B139

MECHANICAL

ELEC.

A-B147

ST

AI

R

-B

C O

R R

ID

O

R C

B-

TELE.

ROOM

B-B051

CORRIDOR

CB-20

EQUIP RM

TE

LE

R

O O

M

CORRIDOR

B- B0

B-B046

CONTROL

B-B034 B-B044

B-B035

MRI

SOILED

B-B042

SCAN ROOM

B- B0

B-B014

ROOM

TREATMENT

CORRIDOR

CB-11

TREATMENT

AREA WELL

B-B022 B-B023

M&O

OFFICE

C-B065

H.A.C.

C-B040

CHUTE

LINEN

C-B039

C-B037

C O

R R

ID

O

R

C -B

4A

SE

C

C-B030A

ENGINEER

BIOMEDICAL

C-B028

C-B035

C -B

C-B127

C -B

C-B034

C-B144

C-B146 C-B149

FREEZER 2

C-B069

GENERATOR

EMERGENCY

C-B115A

C-B118A

C-B112A

C-B110A

C-B114A

C-B097

C-B110

C-B108

C-B107

C-B093C-B096

MISC.

CORRIDOR

EL

EC

TR

O

N

IC

S

SUPPORT

CLERICAL

C O

R R

ID

O

R

C-B170

C-B064

R O

O M

CANTEEN STORAGE

EQUIP.

FIRE

C-B100

SHAFT

C B-

SWITCHGEAR ROOM

C-B074

SERVICE

CANTEEN

C-B072

SERVICE

CANTEEN

C-B073

ELEC.

ROOM

C-B066

OFFICE

STORAGE STORAGE

EMS

A-B151

TE

LE

. R M

C-B031

REPAIR & DEVELOPMENT

C-B077

RECEIVING

C-B076

CLOSET

C-B151

CHASE 1B

A-B150

MECHANICAL ROOM

TE

LE

. R M

TOILET

ELEV.

P-14

P-13

ELEV.

A- B1

TE

LE

PH

O

N E

R O

O M

MEN

P-16

A-B153

ROOM

ELEC.

ELIGIBILITY

ACCOUNTS &

PATIENTS

A-B155

TOILET

R

AM

P U

P

ONCOLOGY

RECEPT.

B-B029

SUPER-

ELECTRIC

SHOP

A-B145

VISOR

ELECTRICAL

SWITCHGEAR

A-B140

FREEZER 3

C-B152

CONTROL

INGREDIENT

C-B155

CORRIDOR

MANAGEMENT

ST

AI

R

-B

MATERIALS

SUPER-

VISOR

MAINTE-

NANCE

ADMIN.

SUPV.

CB-31

C-B121

VESTIBULE

C-B122

COLD ROOM

ENV. SERV.

C-B124

STORAGE

ENG.

SUPERVISOR

C-B038

CB-2

STORAGE

EQUIP.

ELEV.

SUPPLIES/EQUIPMENT

STORAGE/

A-B001

A-B126

STAIR

ELEV.

ROOM

MECH.

ELECTRICAL

SHOP

A-B144

A-B146

CHUTE

LINEN

TOILET

CB-21

CORRIDOR

EQUIP.

ELEV.C-B104 C-B105 C-B106

C-B099

ANCE

VISOR

SUPER-

S-13

CHASE

C H

AS

E

CHASE

C H

AS

E

C H

AS

E

TOILET

ROOM

B-B028

TO

IL

ET

C O

R R

ID

O

R C

O R

R

ID

O R

C B-

STAIRCASE

ROOM

CONFERENCE

#4-B

ENGINEERING

C-B056

C-B111A

D R

ES

S.

R M

B- B0

D

R

ES

S.

R

M

BREAK

ROOM

B-B047

PACS & MRI

DCS

A-B034

C-2

C O

R R

ID

O

R C

B-

MEN

A-B103

CLEAN EQUIP.

A-B082

SPD

A-B085

SUPPLY

A-B074

CORRIDOR

CB-7

WOMEN

TOILETA-B073

TOILET

MEN

A-B070

EQUIPMENT

SUPER-

VISOR

A-B088

EQ

P.

A- B0

A-B089

STORAGE

ROOM

A-B090

STERILE SUPPLY

A-B079

SERVICE

ENVIRO.

WASH

A-B068

LIFT

SHOP

A-B107

CHIEF

CLERK

PLUMBING

A-B108

A-B109

A-B083

RECEPTION

BULK/

CASE CART

EQUIPMENT

STORAGE

EQUIPMENT

A-B069 LO

U

N G

E A-

B0

A-B061

DECONTAMINATION

STERILIZATION

A-B066

ASSEMBLY/

STERILIZATION

A-B065

CART WASH

A-B077

MEN

TOILET

SPD

DECONTAMINATION

A-B063

C H

AS

E

CHIEF, LOG

A-B042

A-B

A-B

WORK

ROOM

SERVICE

CB-9

CORRIDOR

OFFICE

CLERK

A-B156 A-B157

WOMEN

A-B042

A-B041

TEAM

ROOM

ACOS

ELEV.

UP

LO

G

IS

TI

C S

C -B

C-B

C-B058

C-B055

C -B

CONF RM

RAMP

A-B050

OFFICE

FOODSERVICE

PROSTHETICS

A-B033d

CODERS

O

FF

IC

E

O

FF

IC

E

A- B0

PE

T

SC

AN

N

ER

CORRIDOR

A-B016

A-B032

ROOM

C O

R R

ID

O

R

A-B023

QM

R01

A- B0 d

A- B0 c

HIMS

CB-17

ELEC. ROOM

A- B0

C

ELECTRICAL

A-B031

WAITING

TR

AN

SC

R

IP

TI

O N

G-2

DW-1

CLOSET

CHASE

STAIR

#12-B

A-B033A

C B-

12 LEAD

O

FF

IC

E

FISCAL

A-B036

FISCAL

A-B038

FISCAL

A-B039

EQUIPMENTA-

B0 a

Q M

A-B017c A-B017a

ST

O

R

ASST CH

HIMS

CHIEF

CONTROL

A-B011B

R

EA

D

IN

G A-

B0

A

C

LE

AN

A-

B0

U

PT

AK

E

A- B0

U

PT

AK

E

A- B0

U

PT

AK

E

A- B0

U

PT

AK

E

A- B0

U

PT

AK

E

A- B0

SOILED

UTILITY CORRIDOR

CB-00A-B004

PET/CT

A-B011C

A-B011D

TOILET

A-B014C

O R

R

ID

O R

C B-

WAITING

A-B002

TOILET

A-B013

R

EC

P.

A-

B0

A

ROOM

A-B003B

WORK

STAFF

TREATMENT

PLANNING

B-B009

B-B010

OFFICE

B-B011

ONCOLOGY

RADIATION

CHIEF

B-B008

CHIEF

PHYSICIST

TOILET

WOMEN

B-B031 B-B030

TOILET

MEN

MANAGER

B-B007

NURSES

B-B005 B-B004

EXAM3 EXAM2

B-B003

EXAM1

B-B002

WAITING ROOM

B-B001

B-B020

TOILET

B-B021

BREAK ROOM

B-B017

HEALTH TECH

B-B016 MECH.

ROOM

B-B018

B-B019

CLOSET

JANITOR

B-B026

B-B012

OFFICE

RESIDENTS'

UTILITY

TOILET

HANDICAP

SH

AF

T

C-B059

OFFICE

NEW CONF.

ROOM

B-B006

B-B024

C O

R R

ID

O

R

CB-3 C

O

R R

ID

O

R

B-B013

ROOM

KLYSTRON

ENG. LOCKSMITH

ENG.

SERVICE

AUDITORIUM

A-B065A

CB-25

COMMON

OI&T PC STOR./DEVP.

IMS

OI&T SUPV

IMS

C-B029

OI&T MGR

C-B030

OI&T ASSIST.

IMS

C -B

OI&T RECP.&

PRINT AREA

C-B025

IMS

OI&T FCIO

C-B026

OI&T SYSTEMS

C-B022

TELECOM

LO

C

KE

R

C-B130

CORRIDOR

C -B

TO

IL

ET

C-B126

C-B174

WOMEN

TOILET

C-B175

CORRIDOR

NON/

FOOD&/

SUPPLY

STOR.

C-B162

C-B164

COOLER

C-B173 C O

R R

ID

O

R

CLOSET

CLEANING

C -B

LOCKER

TO

IL

ET

ST

AF

F

C H

AS

E

HELP DESK

COMPUTER C

-B

C-B158

ROOM

WAITING ROOM

C-B136 C-B137

DIETICIAN

C-B138

MOVE

C-B135

DIETICIAN

C-B176

CAFETERIA

PA

PE

R S

TO

R

AG

E

C-B134C-B133

C-B132 C-B131

C-B163

OFFICE OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

ROOM

IMS

FOOD

SERVICE

FOREMEN

C-B142

SUPPLY

C-B143 H.A.C.

C-B141

C B-

CB-26

CORRIDOR

A-B064

STERILIZATION

ETO

SEC

C-B024

O I&

T

OI&T

A-B043

CHIEF

111 SEATS

UP

PR

O

ST

H

ET

IC

S

PROSTHETIC

S

C-B117

C -B

7A

OFFICE

EDU SVC.OFFICE

EDU SVC.

OFFICE

EDU SVC.OFFICE

EDU SVC.

OFFICE

EDU SVC.

OFFICE

EDU SVC.

STORAGE

OFFICE

EDU SVC.

OFFICE

EDU SVC.

OFFICE

EDU SVC.

OFFICE

EDU SVC.

OFFICE

EDU SVC.

OFFICE

EDU SVC.

OFFICE

EDU SVC.

EDU SVC.

EDU SVC.

SAFETY

MGR.

ADMIN

SAFETY

RADIATION

S.O.

E.M.S.

INDUSTRIAL

HYGIENIST

STORAGE

CANTEEN

C -B

8A

O

FF

IC

E

PR

O

ST

H

ET

IC

S

COMMMECH

ROOM

A-B025 A-B024

A-B037

OFFICE

A-B101A-B100

A- B1

A-B159

CB-22

LOBBY

CORRIDOR

C B-

C B-

C -3

ROOM

C-1

SPD

C O

R R

ID

O

R C

B-

CB-10

LOBBY

CB-11

LOBBY

C-B148

C-B125

OF SRD

QM

CT ROOM

OFFICE

CONTROL RM.

SHAFT

SOILED

EXAM 5

B-B024

EXAM 4

B- B0

A

D R

ES

S.

R M

DR. B-B027

FCIO

DIETITIAN

ELEC. EQUIP.

ROOM

COOR

W O

STAIR

#14-B

LOGISTICS

LOGISTICS

LOGISTICS

LO

GISTIC

S

LO

GISTIC

S

TRAINING

BLOCK

ROOM

LEAD

WALLS

B-B025

SIMULATOR

BUSINESS AND OTHER USES

5996 SQ FT

BUSINESS AND OTHER USES

ZONE 1IB-12

5341 SQ FT

BUSINESS AND OTHER USES

ZONE 1IB-03

13214 SQ FT

AMBULATORY HEALTH CARE

ZONE 1IB-07

5950 SQ FT

BUSINESS AND OTHER USES

ZONE 1IB-08

10541 SQ FT

INDUSTRIAL OCCUPANCY

ZONE 1IB-05

22021 SQ FT

BUSINESS AND OTHER USES

ZONE 1IB-04

22013 SQ FT

BUSINESS AND OTHER USES

ZONE 1IB-03

18009 SQ FT

ZONE 1IB-06

AR

EA B

AR

EA A

AREA B

AREA A

EP

UNDER

RENOVATION

LC

LC

EX

STAIR #9-B

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

FACP

TOILET

A-B012

FHV

SUITE DESCRIPTIONS

SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

DATEREVISIONS: NUMBER

DRAFT SOC

FP&C Project Number Project NumberProject Title

Location

Issue Date Checked by Drawn by

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE

FVO KW 36Dwg. of

1557.31

EP

LC

TC

EX

HE

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

INDIANAPOLIS, IN

UPDATE STATEMENT OF

CONDITIONS

RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC

1481 W. 10th Street Indianapolis, IN 46202

SPRINKLER / FIRE SMOKE ZONE

VA PLANNING AND ENGINEERING

BASEMENT FLOOR

BUILDING 1

STATEMENT OF CONDITIONS

1SOC-BA

583-19-506

NON-RATED SMOKE PARTITION

1/15/2021 6/1/20

APPROVED EQUIVALENCIES

1. MINI-ATRIUM EQUIVALENCY DATED 12-14-10

2. NON-LISTED URETHANE FOAM IN WALLS THAT ARE NOT FIRE OR SMOKE

BARRIER WALLS EQUIVALENCY DATED 8-26-09

3. BUILDING 7, CSR SINGLE MEANS OF EGRESS EQUIVALENCY DATED 13-7-07

4. NON-SPRINKLERED ELEVATOR MACHINE ROOM EQUIVALENCY DATED

12-27-04

5. NO VENTING OF LINEN CHUTES EQUIVALENCY DATED 5-29-96

6. NON-COMPLIANT PROTECTIVE PLATES EQUIVALENCY DATED 4-21-95

7. PASS-THROUGH CABINETS EQUIVALENCY DATED 3-15-94

8. TRAVEL DISTANCE AND COMMON PATH OF TRAVEL DISTANCES ARE

EXCEEDED.

-BASEMENT ZONE 11B-06 EQUIVALENCY DATED 9-6-12

FINAL SOC 9/16/20

DRAFT OUTER BUILDINGS 10/05/20

DRAFT OUTER BUILDINGS 2 12/18/20

1/15/21 UPDATED FINAL SOC

AREA - A

FULLY SPRINKLERED

MIXED OCCUPANCY

N

BUILDING 1 BASEMENT

A-B021

TRAINING

C O

R R

ID

O

R

SEC./

A- B0

C-B067

ROOM

C-B129

STORAGE

C B-

C-B030

MACHINE SHOP

C-B033

C-B075

C-B118 C-B120

C-B091

TOILET

C-B109

C-B098 C-B095 C-B094

C O

N

TR

O L

C -B

C O

R R

ID

O

R

C-B092

STOR.

EL

EC

TR

O

N

IC

S

MANUAL

SHIPPING

CB-52

CORRIDOR

CB-55

CORRIDOR C-B063

FIRE EQUIP.

MAIL

STOR.

MAINT.

ROOM

STAIR #3-B

MECH.

RECEIVING

AUTOPSY

C-B123

SUITE

C O

R R

ID

O

R

C B-

C

O R

R

ID

O R

CHIEF

COOLER #1

WALK-IN

C-B145CANTEEN

FREEZER 4

ELEV.

A-B154

R

AM

P U

P

#1-B

S-5

TELE. ROOM

P-4 S-6

P-10

LOBBY

D-B009

#7-B

FIRE PUMP

MECHANICAL

ROOM

C -B

C O

R R

ID

O

R

LOBBY

EXERCISE

C B-

MEN

LOCKERS

C-B006

CHUTE

C-B004

LINEN

MECH.

C -B

LOBBY

C-B027

MECH. ROOM

C-B150

C-B153

CB-46

C-B156

CLEAN EQUIP.

SEAMSTRESS

EFFECTS

GOODWILL

FO

R

M

AN

EM

S

G

EN

C H

U

TE

LI

N

EN

STORAGE

C-B19…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .