ATTACHMENT V - 2021 BUILD 1 LIFE SAFETY DRAWINGS.pdf
PDF 24 MB Posted
- Attached to
- Z1DA--Upgrade Fire Alarm System 583-26-221 Federal contract opportunity
- Solicitation number
- 36C25025B0039
About this file
This PDF contains Statement of Conditions (SOC) architectural drawings for Building 1 at the Richard L. Roudebush VA Medical Center in Indianapolis, Indiana. The comprehensive set of floor plans details fire protection, life safety, and occupancy zone configurations across 11 floors (basement through eleventh floor), with each floor displaying a detailed color-coded partition legend indicating fire barrier types, exit routes, and occupancy zones.
The drawings systematically document wall descriptions, fire barrier classifications, smoke zone barriers, and compartmentalization strategies, referencing the 2018 edition of NFPA 101 Life Safety Code. Each floor plan includes specific zone designations, highlighting areas of mixed occupancy types such as business, healthcare, industrial, and ambulatory care. The drawings are part of a fire alarm system upgrade project, showing precise architectural details about how different building zones are constructed and separated to ensure life safety and comply with federal fire protection standards.
View the file
Other files for this federal contract opportunity
Show all 26
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WALL:
DUCTS:
PENETRATIONS:
DOORS*:
WALL:
DUCTS:
DOORS:
WALL:
DUCTS:
PENETRATIONS:
DOORS:
WALL:
DUCTS:
DOORS:
2-HOUR FIRE BARRIER
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND STAIRWELLS OF
4 OR MORE STORIES.
2-HOUR FIRE AND SMOKE ZONE BARRIER
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND
STAIRWELLS OF 4 OR MORE STORIES. THIS COMBINATION WALL IS WHERE A PORTION
OF THE 2-HOUR RATED WALL IS ALSO PART OF THE SMOKE WALL.
1-HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
THIS APPLIES TO 1-HOUR FIRE RATED OCCUPANCY SEPERATIONS, HAZARDOUS ROOM
ENCLOSURES AND STAIRWELLS 3 STORIES OR LESS.
SMOKE ZONE BARRIER
SUBSTANTIAL WALLS AND DOORS TO DIVIDE EACH FLOOR INTO COMPARTMENTS FOR
DEFEND IN PLACE EMERGENCY OPERATIONS. IF THE SMOKE ZONE BARRIER WALL IS
OF MASONRY, GYPSUM BOARD, OR METAL LATH AND PLASTER CONSTRUCTION, AND
THE BARRIER WAS CONSTRUCTED POST 1948, THE SMOKE ZONE BARRIER WALLS ARE
REQUIRED TO BE OF 1 HOUR FIRE RESISTANCE RATING. (NFPA 101, 18.3.2.7.5) SMOKE
ZONE BARRIER WALLS OF WOOD LATH AND PLASTER CONSTRUCTION ARE PERMITTED
TO BE OF A 12 HOUR FIRE RESISTANCE RATING (NFPA 101, 19.3.7.3)
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
NOTE: ALL CODE REFERENCES ARE PER THE 2018 EDITION OF NFPA 101 LIFE SAFETY CODE AND THE OTHER APPLICABLE CODES. FEDERAL FACILITIES FOLLOW 2018 LIFE SAFETY CODE.
DOORS: DOORS THAT ARE NOT PART OF A RATED WALL:
1. NON-LABELED FRAME (NFPA 101 18.3.6.3.1, 19.3.6.3 & 19.3.6.3.3)
2. NON-RATED DOORS PERMITTED IF SPRINKLERED (NFPA 101
18.3.6.3.1, 19.3.6.3.2(2))
3. 20-MINUTE OR SOLID WOOD CORE DOOR IF NOT SPRINKLERED (NFPA 101 19.3.6.3.1) 1 3 4" THICK.
4. POSITIVE LATCHING EXCEPT TOILETS, SHOWER AND SINK
CLOSETS (NFPA 101 18.3.6.3.6 & 19.3.6.3.6)
5. SELF-CLOSING NOT REQUIRED (NFPA 101 19.3.6.3.11)
6. NO MAXIMUM GAP (NFPA 101 18.3.6.3.1 & 19.3.6.3.3)
7. MAXIMUM 1" UNDERCUT (NFPA 101 18.3.6.3.1 & 19.3.6.3.4)
8. UNLIMITED HEIGHT PROTECTIVE PLATE (NFPA 101 18/19.3.6.3.12)
9. TRANSFER GRILLS NOT PERMITTED EXCEPT TOILETS,
SHOWER AND SINK CLOSETS (NFPA 101 18/19.3.6.4)
10. SWING IN ANY DIRECTION
11. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105 5.2.1.1)
NON-RATED SMOKE ZONE PARTITION
FORMER DECOMMISSIONED SMOKE BARRIER RETAINED AS FIRE ALARM/SPRINKLER
ZONE. BUILDING OCCUPANTS PERMITTED TO DEFEND IN PLACE UNTIL DIRECTED BY
THE FIRE DEPARTMENT PER SECTION 16.7.4.3 OF NFPA 99-2018 EDITION AND PRIVATE
MODE AUDIBLE REQUIREMENTS OF SECTION 16.7.4.3 OF NFPA 72-2019 EDITION.
WALL:
DUCTS:
PENETRATIONS:
DOORS:
HEALTH CARE OCCUPANCY CORRIDORS
IF THE SMOKE COMPARTMENT IS SPRINKLERED, THE WALL SHALL FORM A BARRIER TO LIMIT THE TRANSFER OF SMOKE. THE WALL HAS NO REQUIRED FIRE RESISTANCE RATING AND MAY TERMINATE AT A CEILING CONSTRUCTED
TO LIMIT TRANSFER OF SMOKE.
IF THE SMOKE COMPARTMENT IS NOT SPRINKLERED, THE WALL SHALL BE CONTINUOUS FROM THE FLOOR TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK ABOVE. CORRIDOR WALL SHALL HAVE A MINIMUM 1/2 HOUR FIRE RESISTANCE RATING. DOORS ARE MANUALLY CLOSED IN AN EMERGENCY NFPA 101 19.3.6.2 AND 18.3.6.2
PENETRATIONS:
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
ALL DUCT PENETRATIONS ARE PROTECTED BY FIRE DAMPERS.
ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP
MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL
PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE
WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON
THE TOP OF THE FLOOR.
ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 TABLE 4.4.5)-LIMITED TO
MAX AREA LISTED.
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)
10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).
11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT
LEAST ANNUALLY (NFPA 80 5.2.4.1)
* 2 HOUR DOOR REQUIRED FOR STAIRWELLS 4 OR MORE STORIES
(NFPA 101 7.1.3.2.1)(3).
WALL:
DUCTS:
PENETRATIONS:
DOORS:
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
ALL DUCT PENETRATIONS ARE PROTECTED BY COMBINATION FIRE AND
SMOKE DAMPERS. SMOKE DAMPERS ARE NOT REQUIRED WHERE
ADJACENT SMOKE COMPARTMENTS ARE PROTECTED BY QUICK
RESPONSE SPRINKLERS THROUGHOUT EACH COMPARTMENT.
ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP
MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL
PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE
WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON
THE TOP OF THE FLOOR.
ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)
10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).
11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT
LEAST ANNUALLY (NFPA 80 5.2.4.1)
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
STEEL DUCT PENETRATIONS NOT REQUIRED TO BE PROTECTED BY FIRE
DAMPERS.
ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 1-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED
TO BE FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY
REQUIRED TO BE FILLED ON THE TOP OF THE FLOOR.
ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 3/4 OR 1-HOUR DOOR (NFPA 80 4.3.1)*
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 TABLE 4.4.5)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)
10.SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).
11.PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT LEAST
ANNUALLY (NFPA 80 5.2.4.1)
* 1-HOUR DOORS ARE REQUIRED IN STAIRWELLS THAT ARE 3 STORIES OR
LESS. (NFPA101 7.1.3.2.1)(1)
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
ALL DUCT PENETRATIONS ARE PROTECTED BY SMOKE DAMPERS. SMOKE
DAMPERS ARE NOT REQUIRED WHERE ADJACENT SMOKE COMPARTMENTS ARE
PROTECTED BY QUICK RESPONSE SPRINKLERS THROUGHOUT EACH
COMPARTMENT.
ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 1-HOUR FIRE AND SMOKE WALL ASSEMBLIES. PENETRATIONS ARE
TO BE FILLED ON BOTH SIDES OF THE WALL.
ALL DOORS FOR SMOKE BARRIERS REQUIRE THE FOLLOWING:
1. NON-LABELED FRAME (NFPA 101 18.3.7.6)
2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 18.3.7.6) 1 3 4" THICK.
3. MAXIMUM SIZE LISTED WINDOW (NFPA 80 TABLES 4.4.5)
4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 18.3.7.8)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 18.3.7.8)
6. MAXIMUM 1/8" GAP (NFPA 101 18.3.7.6.)
7. MAXIMUM 3/4" UNDERCUT (NFPA 101 8.5.4)
8. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1
9. SWING IN DIRECTION OPPOSITE OF EACH OTHER (NFPA 101 18.3.7.6)
10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105
5.2.1.1)
IF THE HAZARDOUS ROOM HAS A SUSPENDED CEILING CONSTRUCTED TO LIMIT
TRANSFER OF SMOKE, THE WALL HAS NO FIRE RESISTANCE RATING AND MAY
TERMINATE AT THE CEILING. IF THE ROOM DOES NOT HAVE A SUSPENDED
CEILING, THE WALL HAS NO FIRE RESISTANCE RATING AND SHALL EXTEND TO
THE DECK ABOVE.
STEEL DUCT PENETRATIONS ARE NOT REQUIRED TO BE PROTECTED BY FIRE
DAMPERS OR SMOKE DAMPERS.
SEALED WITH NON-FIRE-RATED MATERIALS TO BE RESISTIVE. USE OF LISTED
FIRESTOP MATERIALS IS NOT REQUIRED.
EXISTING HAZARDOUS ROOMS:
1. NON-LABELED FRAME (NFPA 101 19.3.7.9)
2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 19.3.7.6) 1 3 4" THICK.
3. MAXIMUM 1296 SQ. IN. WINDOW (NFPA 101 19.3.6.3.17)
4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 19.3.6.3.5)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 19.3.2.1.3)
6. MAXIMUM 1/8" GAP (NFPA 101 19.3.6.3.1)
7. MAXIMUM 1" UNDERCUT (NFPA 101 19.3.6.3.4)
8. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 19.3.2.1.2)
9. SWING IN ANY DIRECTION
10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA
105 5.2.1.1)
PENETRATIONS:
WALL EXTENDS FROM FLOOR TO SUSPENDED CEILING OR DECK ABOVE.
NO MINIMUM REQUIREMENTS.
NO MINIMUM REQUIREMENTS FOR WALL PENETRATIONS ABOVE A SUSPENDED
CEILING. PENETRATIONS BELOW A SUSPENDED CEILING OR DECK SEALED
WITH NON-FIRE-RATED MATERIALS TO BE SMOKE RESISTIVE.
NON-FIRE-RATED DOORS AND FRAMES SELF CLOSING OR AUTOMATIC CLOSING
IN AN EMERGENCY.
EW
FAAP
FACP
F
AED
SH
EVC
FHV
SYMBOLS LIST
SUITE DESIGNATION
HEALTHCARE AREA OPEN TO CORRIDOR WITH 24
7 SUPERVISION - NO SMOKE
DETECTION REQUIRED.
HEALTHCARE AREA OPEN TO CORRIDOR - SMOKE DETECTION PROVIDED.
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
DATEREVISIONS: NUMBER
DRAFT SOC
FP&C Project Number Project NumberProject Title
Location
Issue Date Checked by Drawn by
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS, LLC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE
FVO KW Dwg. of
1557.31
INDIANAPOLIS, IN
UPDATE STATEMENT OF
CONDITIONS
RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC
1481 W. 10th Street Indianapolis, IN 46202
VA PLANNING AND ENGINEERING X-1
583-19-506
1/15/2021 6/1/20
STATEMENT OF CONDITIONS
WALL DESCRIPTIONS
COVER PAGE
FINAL SOC 9/16/20
DRAFT OUTER BUILDINGS 10/05/20
DRAFT OUTER BUILDINGS 2 12/18/20
1/15/21 UPDATED FINAL SOC
APPLICABLE CODES AND STANDARDS:
1. THE ORIGINAL BUILDING WAS BUILT IN 1982 AND DESIGNED TO THE UNIFORM BUILDING CODE 1979
EDITION.
2. THE JOINT COMMISION HAS ADOPTED THE NATIONAL FIRE CODES PUBLISHED BY THE NATIONAL FIRE
PROTECTION ASSOCIATION. LIFE SAFETY REQUIREMENTS ARE SPECIFICALLY ADDRESSED IN THE 2012
EDITION OF NFPA 101, LIFE SAFETY CODE.
3. ALL NEW CONSTRUCTION OR BUILDING RENOVATIONS ARE REQUIRED TO COMPLY WITH THE 2012 EDITION OF NFPA 101 OR IT'S REFERENCED STANDARDS. EXISTING BUILDING CONDITIONS ARE REQUIRED TO COMPLY WITH THE APPLICABLE CODES OR STANDARDS AT THE TIME OF BUILDING DESIGN AND THE APPLICABLE PROVISIONS FOR EXISTING BUILDINGS IN CURRENT EDITIONS OF APPLICABLE
CODES AND STANDARDS.
4. OTHER NFPA CODES AND STANDARDS:
A. NFPA 10 - PORTABLE FIRE EXTINGUISHERS, 2010 EDITION.
B. NFPA 13 - SPRINKLER SYSTEMS, 2010 EDITION.
C. NFPA 14 - STANDPIPE SYSTEMS, 2010 EDITION.
D. NFPA 20 - FIRE PUMPS, 2019 EDITION
E. NFPA 70 - NATIONAL ELECTRIC CODE, 2011 EDITION.
F. NFPA 72 - NATIONAL FIRE ALARM CODE, 2010 EDITION.
G. NFPA 75 - ELECTRONIC COMPUTER EQUIPMENT, 2017 EDITION.
H. NFPA 80 - FIRE DOORS, 2010 EDITION.
I. NFPA 90A&B - HEATING AND AIR CONDITIONING SYSTEMS, 2012 EDITION.
J. NFPA 96 - COMMERCIAL COOKING EQUIPMENT, 2011 EDITION.
K. NFPA 99 - HEALTH CARE FACILITIES CODE, 2012 EDITION.
L. NFPA 105 - SMOKE DOORS, 2010 EDITION.
M. NFPA 110 - EMERGENCY POWER SYSTEMS, 2010 EDITION.
N. NFPA 241 - CONSTITUTION AND DEMOLITION, 2009 EDITION.
FIRE SPRINKLER SYSTEM:
1. THE COMBINATION STANDPIPE AND FIRE SPRINKLER SYSTEM WAS DESIGNED TO NFPA 13 AND NFPA 14.
2. QUICK RESPONSE TYPE SPRINKLERS ARE INSTALLED THROUGHOUT MOST OF THE BUILDING. STANDARD RESPONSE TYPE SPRINKLERS ARE INSTALLED IN THE ELEVATOR MACHINE ROOMS (NFPA 13- 3.6.4.8).
3. SPRINKLERS WERE INSTALLED IN LIGHT HAZARD AREAS INCLUDING; CORRIDORS, OFFICES, PATIENT CARE AND PATIENT SLEEPING ROOMS AT LIGHT HAZARD 0.10 GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION
AREA OF 225 SQ. FT. (NFPA 13- TABLE 11.2.3.1.2).
4. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP I AREAS INCLUDING; LABORATORIES (WITHOUT FLAMMABLE LIQUIDS), MECHANICAL EQUIPMENT ROOMS, ELECTRICAL SWITCH GEAR ROOMS, REPAIR
SHOPS AND STORAGE ROOMS UNDER 250 SQ. FT. AT A 0.15 GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION AREA OF 150 SQ. FT. (NFPA 13- TABLE 11.2.3.1.2).
5. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP II AREAS INCLUDING GENERAL STORAGE ROOMS OVER 250 SQ. FT. AND LABORATORIES (WITH THE USE OF FLAMMABLE LIQUIDS) AT A 0.20 GPM/1500 SQ.
FT. DENSITY.
6. MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY SPRINKLERS SHALL NOT EXCEED 7'-6" (NFPA 13-8.6.3.2.1). MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY
SPRINKLERS IN SMALL ROOMS (800 SQ. FT. MAXIMUM) SHALL NOT EXCEED 9' FROM ANY SINGLE WALL (NFPA 13-8.6.3.2.4).
7. SPRINKLERS SHALL BE INSTALLED UNDER FIXED OBSTRUCTIONS (I.E. DUCTWORK) OVER 4' WIDE (NFPA 13- 8.10.6.3.2). THE WIDTH OF DUCT INSULATION NOT A FACTOR FOR SPRINKLERS INSTALLED PRIOR TO THE
2013 EDITION ON NFPA 13. SPRINKLERS NOT REQUIRED UNDER NON COMBUSTIBLE OBSTRUCTIONS OVER 4' WIDE WHERE THE BOTTOM OF THE OBSTRUCTION IS A MAXIMUM 24" ABOVE THE FLOOR (NFPA 13- 8.5.5.3.1).
8. SPRINKLERS SHALL BE INSTALLED A MAXIMUM 12" BELOW A CEILING OR FLOOR/ROOF DECK (NFPA 13- 8.6.4.1.1.1) OR A MAXIMUM 22" BELOW A FLOOR/ROOF DECK WITH STRUCTURAL MEMBER OBSTRUCTIONS (NFPA 13- 8.6.4.1.2).
9. SHELVING ON A WALL OR SHELVING AGAINST A WALL INCLUDING STORAGE THEREON SHALL BE PERMITTED TO EXTEND WITHIN THE 18" SPRINKLERS CLEARANCE BELOW CEILING SPRINKLER DEFLECTORS (NFPA 13- 8.5.6.1).
10. WHERE THE 18" CLEARANCE BETWEEN SPRINKLERS AND SHELVING STORAGE CANNOT BE MAINTAINED, SPRINKLERS SHALL BE INSTALLED IN EVERY AISLE (NFPA 13- 8.15.9(2)).
11. CEILING MOUNTED OBSTRUCTIONS (I.E. PATIENT LIFT TRACKS) WITHIN THE 18" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 TABLE 8.6.5.1.2 AND FIGURE 8.6.5.1.2(a).
12. FLOOR MOUNTED OBSTRUCTIONS (I.E. ROOM DIVIDERS OR SHELVING) WITHIN THE 18" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 TABLE 8.6.5.2.2 AND FIGURE 8.6.5.2.2.
SUITES:
1. SUITES ARE UTILIZED TO ILLUSTRATE AREAS WITH THE SAME FUNCTION, USE OF HALLWAYS OR
AISLES AND TO DEFINE THE END OF PUBLIC EXIT CORRIDORS. NO EXIT SIGNS OUTSIDE OF THE
SUITE MAY DIRECT OCCUPANTS INTO A SUITE TO REACH AN EXIT.
2. HEALTH CARE OCCUPANCY SUITES ARE REGULATED BY FUNCTION AND SIZE.
3. HEALTH CARE OCCUPANCY PATIENT SLEEPING SUITES:
A. SINGLE EXIT SUITE - 1,000 SQ. FT. (NFPA 101 -19.2.5.7.2.2)
B. MULTI EXIT SUITE - 5,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.A)
C. MULTI EXIT SUITE WITH STANDARD RESPONSE SPRINKLERS OR COMPLETE SMOKE DETECTION
- 7,500 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.B)
D. MULTI EXIT SUITE WITH DIRECT VISUAL SUPERVISION, QUICK RESPONSE SPRINKLERS AND
COMPLETE SMOKE DETECTION - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.C)
4. PATIENT CARE NON - SLEEPING SUITES:
A. SINGLE EXIT SUITE - 2,500 SQ. FT. (NFPA 101 - 19.2.5.7.3.1.B)
B. MULTI EXIT SUITE - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.3.3)
5. HEALTH CARE OCCUPANCY NON - PATIENT - CARE SUITES FOLLOW THE TRAVEL DISTANCE
REQUIREMENTS AS LISTED IN TABLE A.7.6 OF NFPA 101.
6. SUITES IN OTHER OCCUPANCIES ARE NOT REGULATED IN SIZE BUT STILL FOLLOW THE TRAVEL
DISTANCE REQUIREMENTS AS LISTED IN TABLE A.7.6 OF NFPA 101.
FIRE ALARM SYSTEM:
1. THE FIRE ALARM SYSTEM WAS DESIGNED TO OLDER EDITION OF NFPA 72,
NATIONAL FIRE ALARM CODE.
2. PRIVATE MODE BUILDING OCCUPANT NOTIFICATION IS INSTALLED PER
SECTIONS 19.3.4.3.1 AND 9.6.3.6.3 OF NFPA 101-2012 EDITION.
3. PRIVATE MODE AUDIBLE DEVICES (SPEAKERS) ARE INSTALLED IN
CORRIDORS AND LARGER ROOMS OR SUITES PER SECTION 18.4.4.1 OF
NFPA 72- 2010 EDITION.
4. PRIVATE MODE VISIBLE DEVICES (STROBES) ARE INSTALLED AT
REDUCED QUANTITY AND SPACING PER SECTION 18.6 OF THE NFPA 72-
2010 EDITION.
5. STROBE CIRCUITS ARE REQUIRED TO BE SYNCHRONIZED IN
ACCORDANCE WITH SECTION 18.5.4.3.2(3) OF NFPA 72-2010 EDITION.
6. TYPICAL SMOKE DETECTORS HAVE A 21 FT. RADIUS OF COVERAGE AREA
(NFPA 72- 17.7.3.2.3.1)
7. SMOKE DETECTORS THAT ARE CONNECTED TO THE BUILDING FIRE
ALARM SYSTEM AND LOCATED ON BOTH SIDES OF SMOKE/FIRE DOORS
MAY BE SPACED AT MAXIMUM 21' RADIUS FOR DOOR RELEASE SERVICE
(NFPA 72- 17.7.5.6.1) SMOKE DETECTORS NOT CONNECTED TO THE
BUILDING FIRE ALARM SYSTEM AND USED EXCLUSIVELY FOR SMOKE/FIRE
DOOR RELEASE SHALL BE LOCATED AND SPACED PER NFPA 72- 17.7.5.6.
8. CEILINGS WITH BEAM DEPTHS OF LESS THAN 10% OF CEILING HEIGHT
SHALL BE CONSIDERED A SMOOTH CEILING FOR SMOKE DETECTOR
COVERAGE. CEILINGS WITH BEAM DEPTHS GREATER THAN 10% OF
CEILING HEIGHT SHALL HAVE REDUCED SMOKE DETECTOR SPACING
COVERAGE (NFPA 72- 17.7.3.2.4.2).
9. SMOKE DETECTORS SHALL BE LOCATED ON THE CEILINGS THE BOTTOM
OF BEAMS OR MAXIMUM 12" DOWN FROM THE CEILING TO TOP OF THE
DETECTOR (NFPA 72- 17.7.3.2.1).
10. SMOKE DETECTORS SHALL NOT BE LOCATED DIRECTLY IN THE AIR
STREAM OF SUPPLY AIR REGISTERS (NFPA 72- 17.7.6.3.2).
OCCUPANCY TABLE
THE VA HAS ELECTIVE ACCREDITATION WITH THE JOINT COMMISSION (TJC) FOR HEALTH CARE FACILITIES. SEE THE MEMORANDUM OF UNDERSTANDING (EFFECTIVE 4 SEPTEMBER, 2017) BETWEEN THE VA AND TJC FOR
IMPLEMENTATION OF TJC ENVIRONMENT OF CARE (EC) AND LIFE SAFETY (LS) STANDARDS.
THE VA HAS ELECTIVE ACCREDITATION WITH THE LONG-TERM CARE INSTITUTE, INC. (LTCI) FOR COMMUNITY LIVING CENTERS (CLC). SEE THE CLARIFICATION MEMORANDUM (EFFECTIVE MARCH 29, BETWEEN THE VA AND THE
LTCI FOR IMPLEMENTATION OF LIFE SAFETY REQUIREMENTS.
THE FOLLOWING NATIONWIDE VA EQUIVALENCIES HAVE BEEN REVIEWED AND APPROVED BY THE JOINT
COMMISSION AND APPLY TO ALL BUILDINGS:
1. OVERSIZED PROTECTIVE PLATES PERMITTED ON FIRE RATED DOORS
2. BUSINESS OCCUPANCY DEAD END CORRIDORS PERMITTED TO EXCEED 50 FEET
EQUIVALENCIES
Building No. Floor Health Care Ambulatory Health
Care Business Industrial Dormitory Total 1 11 0 0 0 1,250 0 1,250
1 10 0 0 0 4,660 0 4,660
1 9 0 0 15,118 2,113 0 17,231
1 8 62,672 0 0 855 0 63,527
1 7 40,538 10,553 29,778 0 0 80,869
1 6 69,617 0 10,329 0 0 79,946
1 5 31,976 0 10,272 45,750 0 87,998
1 4 88,186 0 22,514 0 0 110,700
1 3 0 0 75,322 30,661 0 105,983
1 2 0 40,848 78,482 0 0 119,330
1 1 0 53,379 58,737 0 0 112,116
1 Basement 0 11,378 153,089 10,495 0 174,962
1 Sub-Basement 0 0 0 15,481 0 15,481
TOTAL 292,989 116,158 453,641 111,265 0 974,053
1. EXITS (STAIRWAYS, HORIZONTAL EXITS AND DIRECT EXTERIOR EXIT DOORS), OTHER THAN EXTERIOR EXIT DOORS THAT ARE OBVIOUSLY AND CLEARLY IDENTIFIABLE AS EXITS. (GLASS DOORS, VISION PANELS OR ADJACENT WINDOWS) SHALL BE MARKED WITH EXIT SIGNAGE. (SECTION 7.10.1.2.1 OF NFPA 101-2018 EDITION)
2. DIRECTIONAL SIGNS REQUIRED WHERE DIRECTION OF TRAVEL IS NOT APPARENT IN AN EXIT ACCESS
CORRIDOR. (SECTION 7.10.2.1 OF NFPA 101-2018 EDITION)
3. DIRECTIONAL SIGNAGE (EXIT PLACARDS) REQUIRED WITHIN HORIZONTAL COMPONENTS OF EXIT STAIR ENCLOSURES WHERE EGRESS PATH IS NOT OBVIOUS (SECTIONS 7.10.2.2 AND 7.10.1.2.2 OF NFPA 101-2018
EDITION)
4. MAXIMUM VIEWING DISTANCE TO AN EXIT SIGN IN AN EXIT ACCESS CORRIDOR IS 100 FT. (SECTION 7.10.1.5.2 OF
NFPA 101-2018 EDITION)
5. EXIT SIGNS SHALL BE INSPECTED MONTHLY. (SECTION 7.10.9.1 IF NFPA 101-2018 EDITION)
6. DIRECTIONAL SIGNAGE (EXIT PLACARDS OR EXIT SIGNS) WITH OR WITHOUT DIRECTIONAL ARROWS SHOULD BE
PROVIDED IN SUITES USED BY THE GENERAL PUBLIC (LESS THAN 50 TOTAL OCCUPANTS) TO DIRECT THE GENERAL PUBLIC BACK TO THE WAITING AREA. (SECTION 7.10.2.1 OF NFPA 101-2018 EDITION)
7. ROOMS OR SUITES OF ROOMS USED FOR 50 OCCUPANTS OR MORE SHALL BE PROVIDED WITH EXIT SIGNAGE.
(SECTIONS 13.2.10.1 AND 3.3.196.2 OF NFPA 101-2018 EDITION)
EXIT SIGN REQUIREMENTS
DATEREVISIONS: NUMBER
DRAFT SOC
FP&C Project Number Project NumberProject Title
Location
Issue Date Checked by Drawn by
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS, LLC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE
FVO KW Dwg. of
1557.31
INDIANAPOLIS, IN
UPDATE STATEMENT OF
CONDITIONS
RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC
1481 W. 10th Street Indianapolis, IN 46202
VA PLANNING AND ENGINEERING X-2
583-19-506
1/15/2021 6/1/20
STATEMENT OF CONDITIONS
WALL DESCRIPTIONS
COVER PAGE
FINAL SOC 9/16/20
DRAFT OUTER BUILDINGS 10/05/20
DRAFT OUTER BUILDINGS 2 12/18/20
P
IP
E B
A S
E M
E N
T
CHASE
C-SB4
SIGNAL
VAULT
ELECTRICAL
VAULT
SUB-BASEMENT
C-SB1
R O
O M
C -S
B
UP
PIPE BASEMENT
UP
UP
STEAM VAULT
TUNNEL
MECHANICAL
UTILITY CRAWL
SPACE
DIETARY
ELEV. PIT
ELEV. PIT
MECHANICAL STORAGE
SUB-BASEMENT
CHASE
CHASE
STAIR #12-SB
STAIR #7-SB
SPACE
UTILITY CRAWL
UTILITY CRAWL
SPACE SPACE
SPACE
UTILITY CRAWL
CRAWL
UTILITY
SPACE SPACE SPACE
SPACE
UTILITY CRAWL
SPACE
SPACE
UTILITY CRAWL SPACE
SPACE
SPACE
UTILITY CRAWL
SPACE
UTILITY CRAWL
UTILITY CRAWL
UTILITY
CRAWL
UTILITY
SPACE
UTILITY CRAWL
SPACE
SPACE
UTILITY CRAWL
CRAWL
UTILITY
SPACE
CRAWL
SPACE
SPACE
UTILITY CRAWL
SPACE
UTILITY CRAWL
SERVICE ROOM
SPACE
CHASE
C-SB3
M E
C H
A N
IC
A
L
DUMBWAITER PIT
DUMBWAITER PIT
ELEV. PIT
ELEV. PIT
ELEV.
PIT
MECH. ROOM FLOOR
VERTICAL
LIFT
MEDICAL RECORD FILES
UP
STAIR #1-SB
& RADIOLOGY
UTILITY CRAWL
UNEXCAVATED
SUB-BASEMENT
ELEVATOR PIT
CHASE
CHASE
CHASE
ELEVATOR PIT
C H
A S
E
STAIR
STAIR #14-SB
STAIR #8-SB
STAIR #9
STAIR
THIS AREA SHOWN FOR REFERENCE ONLY
SEE BASEMENT FLOOR PLAN
SPACE
UTILITY CRAWL
SPACE
UTILITY CRAWL
UTILITY CRAWL
SPACE
UTILITY CRAWL
CRAWL
UTILITY
CRAWL
UTILITY
UTILITY CRAWL UTILITY CRAWL
UTILITY CRAWL
UTILITY CRAWL
SPACE
SPACE
UTILITY CRAWL
SPACE
UTILITY CRAWL
SPACE
UTILITY CRAWL
SPACESPACE
UTILITY CRAWL
CRAWL
SPACE SPACE
CRAWL
UTILITY
SPACE
SPACE
UTILITY CRAWL
UTILITY CRAWL
SPACE
UTILITY CRAWL
UTILITY CRAWL
SPACE
UTILITY
UTILITY CRAWL
SPACE
INDUSTRIAL OCCUPANCY
ZONE 1ISB-01
AREA B
AREA C
AR
EA
A
AR
EA
C
AREA B
AREA A
1190 SQ FT
INDUSTRIAL OCCUPANCY
ZONE 1ISB-02
1138 SQ FT
INDUSTRIAL OCCUPANCY
ZONE 1ISB-03
2757 SQ FT
INDUSTRIAL OCCUPANCY
ZONE 1ISB-04
10217 SQ FT
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SYMBOLS LIST
HORIZONTAL EXIT PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
DATEREVISIONS: NUMBER
DRAFT SOC
FP&C Project Number Project NumberProject Title
Location
Issue Date Checked by Drawn by
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS, LLC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE
FVO KW 36Dwg. of
1557.31
EP
LC
TC
EX
HE
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
SUITE DESIGNATION
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
INDIANAPOLIS, IN
UPDATE STATEMENT OF
CONDITIONS
RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC
1481 W. 10th Street Indianapolis, IN 46202
SPRINKLER / FIRE SMOKE ZONE
VA PLANNING AND ENGINEERING
SUB BASEMENT FLOOR
BUILDING 1
STATEMENT OF CONDITIONS
1SOC-SB
583-19-506
NON-RATED SMOKE PARTITION
1/15/2021 6/1/20
APPROVED EQUIVALENCIES
1. MINI-ATRIUM EQUIVALENCY DATED 12-14-10
2. NON-LISTED URETHANE FOAM IN WALLS THAT ARE NOT FIRE OR SMOKE
BARRIER WALLS EQUIVALENCY DATED 8-26-09
3. BUILDING 7, CSR SINGLE MEANS OF EGRESS EQUIVALENCY DATED 13-7-07
4. NON-SPRINKLERED ELEVATOR MACHINE ROOM EQUIVALENCY DATED
12-27-04
5. NO VENTING OF LINEN CHUTES EQUIVALENCY DATED 5-29-96
6. NON-COMPLIANT PROTECTIVE PLATES EQUIVALENCY DATED 4-21-95
7. PASS-THROUGH CABINETS EQUIVALENCY DATED 3-15-94
8. TRAVEL DISTANCE AND COMMON PATH OF TRAVEL DISTANCES ARE
EXCEEDED.
-BASEMENT ZONE 11B-06 EQUIVALENCY DATED 9-6-12
FINAL SOC 9/16/20
DRAFT OUTER BUILDINGS 10/05/20
DRAFT OUTER BUILDINGS 2 12/18/20
1/15/21 UPDATED FINAL SOC
COMPOSITE
FULLY SPRINKLERED
INDUSTRIAL OCCUPANCY
N
BUILDING 1 SUB BASEMENT
P
IP
E B
A S
E M
E N
T
CHASE
C-SB4
SIGNAL
VAULT
ELECTRICAL
VAULT
SUB-BASEMENT
C-SB1
R O
O M
C -S
B
UP
UP
STEAM VAULT
TUNNEL
MECHANICAL
UTILITY CRAWL
SPACE
DIETARY
SUB-BASEMENT
STAIR #12-SB
SPACE
SPACE
UTILITY CRAWL
SPACE
UTILITY CRAWL
SPACE
SPACE
UTILITY CRAWL
CRAWL
UTILITY
SPACE
CRAWL
SPACE
SPACE
UTILITY CRAWL
SPACE
UTILITY CRAWL
SERVICE ROOM
CHASE
C-SB3
M E
C H
A N
IC
A
L
DUMBWAITER PIT
DUMBWAITER PIT
ELEV. PIT
ELEV. PIT
ELEV.
PIT
MECH. ROOM FLOOR
VERTICAL
LIFT
UNEXCAVATED
CHASE
CHASE
CHASE
ELEVATOR PIT
C H
A S
E
STAIR
STAIR #14-SB
STAIR #9
STAIR
UTILITY CRAWL
SPACE
UTILITY CRAWL
UTILITY CRAWL
SPACE
UTILITY CRAWL
UTILITY CRAWL
SPACE
UTILITY
UTILITY CRAWL
SPACE
AR
EA
A
AR
EA
C
AREA B
AREA A
INDUSTRIAL OCCUPANCY
ZONE 1ISB-02
1138 SQ FT
INDUSTRIAL OCCUPANCY
ZONE 1ISB-03
2757 SQ FT
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SYMBOLS LIST
HORIZONTAL EXIT PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
DATEREVISIONS: NUMBER
DRAFT SOC
FP&C Project Number Project NumberProject Title
Location
Issue Date Checked by Drawn by
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS, LLC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE
FVO KW 36Dwg. of
1557.31
EP
LC
TC
EX
HE
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
SUITE DESIGNATION
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
INDIANAPOLIS, IN
UPDATE STATEMENT OF
CONDITIONS
RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC
1481 W. 10th Street Indianapolis, IN 46202
SPRINKLER / FIRE SMOKE ZONE
VA PLANNING AND ENGINEERING
SUB BASEMENT FLOOR
BUILDING 1
STATEMENT OF CONDITIONS
1-SOCSBA
583-19-506
NON-RATED SMOKE PARTITION
1/15/2021 6/1/20
APPROVED EQUIVALENCIES
1. MINI-ATRIUM EQUIVALENCY DATED 12-14-10
2. NON-LISTED URETHANE FOAM IN WALLS THAT ARE NOT FIRE OR SMOKE
BARRIER WALLS EQUIVALENCY DATED 8-26-09
3. BUILDING 7, CSR SINGLE MEANS OF EGRESS EQUIVALENCY DATED 13-7-07
4. NON-SPRINKLERED ELEVATOR MACHINE ROOM EQUIVALENCY DATED
12-27-04
5. NO VENTING OF LINEN CHUTES EQUIVALENCY DATED 5-29-96
6. NON-COMPLIANT PROTECTIVE PLATES EQUIVALENCY DATED 4-21-95
7. PASS-THROUGH CABINETS EQUIVALENCY DATED 3-15-94
8. TRAVEL DISTANCE AND COMMON PATH OF TRAVEL DISTANCES ARE
EXCEEDED.
-BASEMENT ZONE 11B-06 EQUIVALENCY DATED 9-6-12
FINAL SOC 9/16/20
DRAFT OUTER BUILDINGS 10/05/20
DRAFT OUTER BUILDINGS 2 12/18/20
1/15/21 UPDATED FINAL SOC
AREA - A
FULLY SPRINKLERED
INDUSTRIAL OCCUPANCY
N
ELEV. PIT
ELEV. PIT
MECHANICAL STORAGE
STAIR #7-SB
UTILITY
CRAWL
UTILITY
UP
SUB-BASEMENT
STAIR #8-SB
CRAWL CRAWL
UTILITY
AREA B
AREA C
INDUSTRIAL OCCUPANCY
ZONE 1ISB-04
10217 SQ FT
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SYMBOLS LIST
HORIZONTAL EXIT PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
DATEREVISIONS: NUMBER
DRAFT SOC
FP&C Project Number Project NumberProject Title
Location
Issue Date Checked by Drawn by
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS, LLC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE
FVO KW 36Dwg. of
1557.31
EP
LC
TC
EX
HE
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
SUITE DESIGNATION
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
INDIANAPOLIS, IN
UPDATE STATEMENT OF
CONDITIONS
RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC
1481 W. 10th Street Indianapolis, IN 46202
SPRINKLER / FIRE SMOKE ZONE
VA PLANNING AND ENGINEERING
SUB BASEMENT FLOOR
BUILDING 1
STATEMENT OF CONDITIONS
1SOC-SBB
583-19-506
NON-RATED SMOKE PARTITION
1/15/2021 6/1/20
APPROVED EQUIVALENCIES
1. MINI-ATRIUM EQUIVALENCY DATED 12-14-10
2. NON-LISTED URETHANE FOAM IN WALLS THAT ARE NOT FIRE OR SMOKE
BARRIER WALLS EQUIVALENCY DATED 8-26-09
3. BUILDING 7, CSR SINGLE MEANS OF EGRESS EQUIVALENCY DATED 13-7-07
4. NON-SPRINKLERED ELEVATOR MACHINE ROOM EQUIVALENCY DATED
12-27-04
5. NO VENTING OF LINEN CHUTES EQUIVALENCY DATED 5-29-96
6. NON-COMPLIANT PROTECTIVE PLATES EQUIVALENCY DATED 4-21-95
7. PASS-THROUGH CABINETS EQUIVALENCY DATED 3-15-94
8. TRAVEL DISTANCE AND COMMON PATH OF TRAVEL DISTANCES ARE
EXCEEDED.
-BASEMENT ZONE 11B-06 EQUIVALENCY DATED 9-6-12
FINAL SOC 9/16/20
DRAFT OUTER BUILDINGS 10/05/20
DRAFT OUTER BUILDINGS 2 12/18/20
1/15/21 UPDATED FINAL SOC
AREA - B
FULLY SPRINKLERED
INDUSTRIAL OCCUPANCY
N
C-SB4
SIGNAL
VAULT
ELECTRICAL
VAULT
SUB-BASEMENT
C-SB1
R O
O M
C -S
B
PIPE BASEMENT
UP
DIETARY
CHASE
CHASE
SPACE
UTILITY CRAWL
UTILITY CRAWL
SPACE SPACE
SPACE
UTILITY CRAWL
CRAWL
UTILITY
SPACE SPACE SPACE
SPACE
UTILITY CRAWL
SPACE
SPACE
UTILITY CRAWL SPACE
SPACE
SPACE
UTILITY CRAWL
SPACE
UTILITY CRAWL
UTILITY CRAWL
UTILITY
CRAWL
UTILITY
SERVICE ROOM
SPACE
C-SB3
M E
C H
A N
IC
A
L
VERTICAL
LIFT
MEDICAL RECORD FILES
STAIR #1-SB
& RADIOLOGY
UTILITY CRAWL
UNEXCAVATED
ELEVATOR PIT
STAIR #14-SB
STAIR #8-SB
THIS AREA SHOWN FOR REFERENCE ONLY
SEE BASEMENT FLOOR PLAN
SPACE
UTILITY CRAWL
SPACE
UTILITY CRAWL
UTILITY CRAWL
SPACE
UTILITY CRAWL
CRAWL
UTILITY
CRAWL
UTILITY
UTILITY CRAWL UTILITY CRAWL
UTILITY CRAWL
UTILITY CRAWL
SPACE
SPACE
UTILITY CRAWL
SPACE
UTILITY CRAWL
SPACE
UTILITY CRAWL
SPACESPACE
UTILITY CRAWL
CRAWL
SPACE SPACE
CRAWL
UTILITY
SPACE
INDUSTRIAL OCCUPANCY
ZONE 1ISB-01
AREA B
AREA C
1190 SQ FT
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SYMBOLS LIST
HORIZONTAL EXIT PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
DATEREVISIONS: NUMBER
DRAFT SOC
FP&C Project Number Project NumberProject Title
Location
Issue Date Checked by Drawn by
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS, LLC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE
FVO KW 36Dwg. of
1557.31
EP
LC
TC
EX
HE
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
SUITE DESIGNATION
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
INDIANAPOLIS, IN
UPDATE STATEMENT OF
CONDITIONS
RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC
1481 W. 10th Street Indianapolis, IN 46202
SPRINKLER / FIRE SMOKE ZONE
VA PLANNING AND ENGINEERING
SUB BASEMENT FLOOR
BUILDING 1
STATEMENT OF CONDITIONS
1SOC-SBC
583-19-506
NON-RATED SMOKE PARTITION
1/15/2021 6/1/20
APPROVED EQUIVALENCIES
1. MINI-ATRIUM EQUIVALENCY DATED 12-14-10
2. NON-LISTED URETHANE FOAM IN WALLS THAT ARE NOT FIRE OR SMOKE
BARRIER WALLS EQUIVALENCY DATED 8-26-09
3. BUILDING 7, CSR SINGLE MEANS OF EGRESS EQUIVALENCY DATED 13-7-07
4. NON-SPRINKLERED ELEVATOR MACHINE ROOM EQUIVALENCY DATED
12-27-04
5. NO VENTING OF LINEN CHUTES EQUIVALENCY DATED 5-29-96
6. NON-COMPLIANT PROTECTIVE PLATES EQUIVALENCY DATED 4-21-95
7. PASS-THROUGH CABINETS EQUIVALENCY DATED 3-15-94
8. TRAVEL DISTANCE AND COMMON PATH OF TRAVEL DISTANCES ARE
EXCEEDED.
-BASEMENT ZONE 11B-06 EQUIVALENCY DATED 9-6-12
FINAL SOC 9/16/20
DRAFT OUTER BUILDINGS 10/05/20
DRAFT OUTER BUILDINGS 2 12/18/20
1/15/21 UPDATED FINAL SOC
AREA - C
FULLY SPRINKLERED
INDUSTRIAL OCCUPANCY
N
EX
G-1
ELEV. CHASE
DN
UP
UP
UP
UP
WATER SOFTENER
A-B110
WASH
A-B109A
REPAIR
LOBBY
A-B114
SHOP
A-B115
CB-3
CARPENTER
SHOP
A-B121
A-B116 A-B120
A-B108A
A-B117
SUPER-
A-B118 A-B119
OFFICE
A-B040
A-B043
A-B021
TRAINING
C O
R R
ID
O
R
SEC./
A- B0
OFFICE
A-B136
REPAIR ENG.
A-B142 A-B143
A-B148
ROOM
B-B033 B-B045
ROOM
RECEPT.
OFFICE
ROOM
UTILITY
B-B041
OFFICE
B-B036
C O
N
TR
O L
R O
O M
B-B038 ROOM
B-B015
A-B137
C-B067
ROOM
C-B129
STORAGE
C B-
C-B030
MACHINE SHOP
C-B033
C-B075
C-B118 C-B120
C-B091
TOILET
C -B
C-B113A
C-B117A C-B102
WOMEN
C-B103 C-B109
C-B098 C-B095 C-B094
C O
N
TR
O L
C -B
C O
R R
ID
O
R
C O
R R
ID
O
R
C-B092
STOR.
EL
EC
TR
O
N
IC
S
MANUAL
SHIPPING
CB-52
CORRIDOR
CB-55
CORRIDOR C-B063
FIRE EQUIP.
STOR.
MAINT.
ROOM
STAIR #3-B
MECH.
RECEIVING
EQUIP.
AUTOPSY
C-B123
SUITE
C O
R R
ID
O
R
C B-
C
O R
R
ID
O R
R.O. EQUIPMENT
CHIEF
COOLER #1
WALK-IN
C-B145CANTEEN
FREEZER 4
ELEV.
A-B154
R
AM
P U
P
UP
#1-B
S-5
TELE. ROOM
P-4 S-6
P-10
LOBBY
D-B009
#7-B
FIRE PUMP
MECHANICAL
ROOM
C -B
C O
R R
ID
O
R
LOBBY
EXERCISE
C B-
MEN
LOCKERS
C-B006
CHUTE
C-B004
LINEN
MECH.
C -B
LOBBY
C-B027
RADIATION
OFFICE
MECH. ROOM
SUPER-
ELECTRIC
SHOP
A-B145
VISOR
C-B150
C-B153
CB-46
C-B156
CLEAN EQUIP.
SEAMSTRESS
EFFECTS
GOODWILL
FO
R
M
AN
EM
S
G
EN
C H
U
TE
LI
N
EN
STORAGE
C-B191
UP
A-B045
PARTS
STORAGE
C-B032
STORAGE
FLAMMABLE
C -B
LOBBY
VIEWING ROOM
C-B119
BIOMEDICAL
CORRIDOR
C-B071
SVCS.
ENG.
ELEV.
S-11
S-12
ELEV.
P-15
DOCK
LOADING
STAIR #6-B
C-B115
CORRIDOR
C-B019
MEN
STORAGE
UP
UP
STORAGE
A-B138
ELECTRICAL
C-B157
DN
CORRIDOR
FIRE
EL
EV
AT
O
R
CHASE
ELEV.
ELEV.ELEV. ELEV. ELEV.
AR
EA
AREA
AREA
AREA
FREIGHT
GENERATOR
SUBSTATION
ST
O
R
AG
E
SWITCH GEAR
MAINTEN-
ANCE
MAINTEN-
VISOR
SUPER-
FUTURE
ENVIRO.
ROOM
ELEC.
AR
EA
W
AY
S
CHASE
ROOM
C O
O R
ID
O
R
CHUTE
LIFT
SH
AF
T
SHAFT
SH
AF
T
SH
AF
T
"E
"F
"H
SHAFT
M
EC
H
CB-38
RAMP UP
STAIR
A-B123
E-B004
UP
B- B0
B-B043
OFFICE
WAITING
OF QM
255 SQ.FT.
C-1
TOILET
BREAKOUT
A-B081
SHOP
MASONRY
A-B102
CLOSET
CLOSET
A-B104
CLOSET
A-B105
AC SHOP
A-B106
STORAGE
CLERKS
CORRIDOR
CB-7
LOUNGE
A-B071
A-B072
LIFT
CORRIDOR
CB-30
LI
FT LIFT
ELEC.
A-B075
AREA
SUPPLY STORAGE
PLUMBING
ASST.
CHIEF
A-B087
TOILET
WOMEN
A-B084
A-B078
SHOP
SPS STORAGE
STORAGE
A-B080
DECON
A-B067
PREPARATION/
ROOM
A-B062
SCOPE
ETO
ASST. LOG
A-B048
ENVIRONMENTAL
TOILET
FOR QCIS
C-B188
P-1
DN
O
FF
IC
E
C-B062
C-B055
HELP
UP
DN
UP
D-B010
ROOM
GENERATOR
UP
FOREMAN
EMS
C-B192
SERVICES
C-B185
RECEIVING
DN
R
AM
P
IMS
QCIS/QM
A-B033B
SECTION
CODING
ICRA
A-B018b
QM
A-B017b
SC
AN
N
IN
G
HIMS
O
FF
IC
E
ENVIRONMENTAL
UP
UP
A-B113 OUTDOOR
STORAGE
A-B112
AND WASHDOWN
MAINTENANCE
A-B110
WHEELCHAIR
CB-5
PAINT
A-B125
COLLECT.
DUST
LOBBY
ELECTRICAL
PRINTS
BLUE
MACHINE AND
WELDING SHOP
ANCE
MAINTEN-
VISOR
A-B044
R01
A-B043b
CHIEF
LOG SERVICE
A-B030
P&H COPY
A-B135
BED
A-B141
LOCKSMITH
SERVICE
C O
R R
ID
O
R C
B-
ELECTRICAL
SWITCHGEAR
A-B139
MECHANICAL
ELEC.
A-B147
ST
AI
R
-B
C O
R R
ID
O
R C
B-
TELE.
ROOM
B-B051
CORRIDOR
CB-20
EQUIP RM
TE
LE
R
O O
M
CORRIDOR
B- B0
B-B046
CONTROL
B-B034 B-B044
B-B035
MRI
SOILED
B-B042
SCAN ROOM
B- B0
B-B014
ROOM
TREATMENT
CORRIDOR
CB-11
TREATMENT
AREA WELL
B-B022 B-B023
M&O
OFFICE
C-B065
H.A.C.
C-B040
CHUTE
LINEN
C-B039
C-B037
C O
R R
ID
O
R
C -B
4A
SE
C
C-B030A
ENGINEER
BIOMEDICAL
C-B028
C-B035
C -B
C-B127
C -B
C-B034
C-B144
C-B146 C-B149
FREEZER 2
C-B069
GENERATOR
EMERGENCY
C-B115A
C-B118A
C-B112A
C-B110A
C-B114A
C-B097
C-B110
C-B108
C-B107
C-B093C-B096
MISC.
CORRIDOR
EL
EC
TR
O
N
IC
S
SUPPORT
CLERICAL
C O
R R
ID
O
R
C-B170
C-B064
R O
O M
CANTEEN STORAGE
EQUIP.
FIRE
C-B100
SHAFT
C B-
SWITCHGEAR ROOM
C-B074
SERVICE
CANTEEN
C-B072
SERVICE
CANTEEN
C-B073
ELEC.
ROOM
C-B066
OFFICE
STORAGE STORAGE
EMS
A-B151
TE
LE
. R M
C-B031
REPAIR & DEVELOPMENT
C-B077
RECEIVING
C-B076
CLOSET
C-B151
CHASE 1B
A-B150
MECHANICAL ROOM
TE
LE
. R M
TOILET
ELEV.
P-14
P-13
ELEV.
A- B1
TE
LE
PH
O
N E
R O
O M
MEN
P-16
A-B153
ROOM
ELEC.
ELIGIBILITY
ACCOUNTS &
PATIENTS
A-B155
TOILET
R
AM
P U
P
P-3P-2
D-B008
ROOM
GENERATOR
D-B011
D-B001
D-B006
D-B004
STAIR
ROOM
TO
IL
ET
LO
C
KE
R
R O
O M
LOCKERS
C-B010
C B-
A
#2-B
EMPLOYEE
ROOM
C-B008
CORRIDORC
O
R R
ID
O
R
IMS
C-B003
ROOM
C-B203
C-B017
UPS ROOM
OFFICE
C-B016
PI
PE
C H
AS
E
R
AM
P
C-B179
ONCOLOGY
RECEPT.
B-B029 C-B021
SUPER-
ELECTRIC
SHOP
A-B145
VISOR
ELECTRICAL
SWITCHGEAR
A-B140
COMMUNICATIONS ROOM
STAIR
FREEZER 3
C-B152
CONTROL
INGREDIENT
C-B154
OFFICE
C-B155
CORRIDOR CORRIDOR
DISHWASH./
C-B201
C-B200
CLEAN LINEN
C-B196C -B
C -B
4C
LO
SE
T C
-B
OFFICE
C-B187
EQUIP
FIRE
MANAGEMENT
ST
AI
R
-B
MECH.
ROOM
C -B
CLOSET
C-B018
MATERIALS
SUPER-
VISOR
MAINTE-
NANCE
ADMIN.
SUPV.
VO
C
R
EH
AB
C O
M
PU
TE
R
L
AB
FIRE
EQUIP.
C-B012
CB-31
C-B121
VESTIBULE
C-B122
COLD ROOM
ENV. SERV.
C-B124
STORAGE
ENG.
SUPERVISOR
C-B038
CB-2
STORAGE
EQUIP.
ELEV.
SUPPLIES/EQUIPMENT
STORAGE/
A-B001
A-B126
STAIR
ELEV.
ROOM
MECH.
SWITCH GEAR
TOILET
C-B007
DN
DN
ELECTRICAL
SHOP
A-B144
A-B146
CHUTE
LINEN
TOILET
CB-21
CORRIDOR WASH
C-B180
OPEN
D -B
EQUIP.
M
AC
H
IN
E
EQ
U
IP
M
EN
T
CHASE
DN
D-B003
ELECTRICAL
ROOM
P-9 P-8
ELEV.
ELEV.
ELEV.
ELEV.
AR
EA
AREA
AR
EA
AR
EA
ELEVATOR
LOBBY
EMERGENCY
TRAINING
EMS
SUBSTATION
C-B104 C-B105 C-B106
C-B099
ANCE
VISOR
SUPER-
S-13
ELEV.
S-7
C H
AS
E
C H
AS
E
AR
EA
W
AY
S
C-B178
SERVICE
CHASE
C H
AS
E
CHASE
C H
AS
E
CORRIDOR
CB-36
C H
AS
E
TOILET
ROOM
WOMEN
W O
M
EN
B-B028
SHAFT
SH
AF
T
SHAFT
SHAFT
SH
AF
T
SHAFT
"A" "B" "C"
"D
"G
"K" "J"
TO
IL
ET
C H
AS
E
PASSAGE
C O
R R
ID
O
R C
O R
R
ID
O R
C B-
STAIRCASE
STAIRCASE
ROOM
CONFERENCE
SUPV
STAIR
#4-B
ENGINEERING
C-B056
C-B111A
#14-B
STAIR
D R
ES
S.
R M
B- B0
D
R
ES
S.
R
M
BREAK
ROOM
B-B047
PACS & MRI
DCS
A-B034
WAREHOUSE
EB-028
SUPERVISOR
OFFICE
EB-029
C-2
C O
R R
ID
O
R C
B-
MEN
A-B103
CLEAN EQUIP.
A-B082
SPD
A-B085
SUPPLY
A-B074
CORRIDOR
CB-7
WOMEN
TOILETA-B073
TOILET
MEN
A-B070
EQUIPMENT
SUPER-
VISOR
A-B088
EQ
P.
A- B0
A-B089
STORAGE
ROOM
A-B090
STERILE SUPPLY
A-B079
SERVICE
ENVIRO.
WASH
A-B068
LIFT
SHOP
A-B107
CHIEF
CLERK
PLUMBING
A-B108
A-B109
A-B083
RECEPTION
BULK/
CASE CART
EQUIPMENT
STORAGE
EQUIPMENT
A-B069 LO
U
N G
E A-
B0
A-B061
DECONTAMINATION
STERILIZATION
A-B066
ASSEMBLY/
STERILIZATION
A-B065
CART WASH
A-B077
MEN
TOILET
SPD
DECONTAMINATION
A-B063
C H
AS
E
CHIEF, LOG
A-B042
A-B
A-B
WORK
ROOM
SERVICE
CB-9
CORRIDOR
OFFICE
CLERK
A-B156 A-B157
WOMEN
A-B042
A-B041
TEAM
ROOM
ACOS
ELEV.
UP
LO
G
IS
TI
C S
C -B
C-B
C-B058
C-B055
STAIR
DN
DN
C -B
CONF RM
RAMP
A-B050
OFFICE
FOODSERVICE
PROSTHETICS
A-B033d
CODERS
O
FF
IC
E
O
FF
IC
E
A- B0
IMS CLO
E-B002
PE
T
SC
AN
N
ER
CORRIDOR
A-B016
A-B032
ROOM
C O
R R
ID
O
R
A-B023
QM
R01
A- B0 d
A- B0 c
HIMS
CB-17
ELEC. ROOM
A- B0
C
ELECTRICAL
A-B031
WAITING
TR
AN
SC
R
IP
TI
O N
G-2
DW-1
CLOSET
CHASE
STAIR
#12-B
A-B033A
C B-
12 LEAD
O
FF
IC
E
FISCAL
A-B036
FISCAL
A-B038
FISCAL
A-B039
EQUIPMENTA-
B0 a
Q M
A-B017c A-B017a
ST
O
R
ASST CH
HIMS
CHIEF
CONTROL
A-B011B
R
EA
D
IN
G A-
B0
A
C
LE
AN
A-
B0
U
PT
AK
E
A- B0
U
PT
AK
E
A- B0
U
PT
AK
E
A- B0
U
PT
AK
E
A- B0
U
PT
AK
E
A- B0
SOILED
UTILITY CORRIDOR
CB-00A-B004
PET/CT
A-B011C
A-B011D
TOILET
A-B014C
O R
R
ID
O R
C B-
WAITING
A-B002
TOILET
A-B013
R
EC
P.
A-
B0
A
ROOM
A-B003B
WORK
STAFF
TREATMENT
PLANNING
B-B009
B-B010
OFFICE
B-B011
ONCOLOGY
RADIATION
CHIEF
B-B008
CHIEF
PHYSICIST
TOILET
WOMEN
B-B031 B-B030
TOILET
MEN
MANAGER
B-B007
NURSES
B-B005 B-B004
EXAM3 EXAM2
B-B003
EXAM1
B-B002
WAITING ROOM
B-B001
B-B020
TOILET
B-B021
BREAK ROOM
B-B017
HEALTH TECH
B-B016 MECH.
ROOM
B-B018
B-B019
CLOSET
JANITOR
B-B026
B-B012
OFFICE
RESIDENTS'
UTILITY
TOILET
HANDICAP
SH
AF
T
C-B059
OFFICE
NEW CONF.
ROOM
B-B006
B-B024
C O
R R
ID
O
R
CB-3 C
O
R R
ID
O
R
B-B013
ROOM
KLYSTRON
ENG. LOCKSMITH
ENG.
SERVICE
C-B193
GOODWILL
C -B
3A
C-B003BEL
EC
T.
R
O O
M MECH.
ROOM
AUDITORIUM
A-B065A
IMS
C-B001
IMS
C-B002
IMS
OI&T FIBER
OI&T APP DEVP/SUPPORT
CB-25
COMMON
OI&T PC STOR./DEVP.
C-B014
OI&T CS
C-B013
OI&T IS/
C-B202
IMS
OI&T CSU
IMS
WAREHOUSE
IMS
OI&T SUPV
IMS
C-B029
OI&T MGR
C-B030
OI&T ASSIST.
IMS
C -B
OI&T RECP.&
PRINT AREA
C-B025
IMS
OI&T FCIO
C-B026
OI&T SYSTEMS
C-B022
TELECOM
LO
C
KE
R
C-B130
CORRIDOR
C -B
TO
IL
ET
C-B126
C-B174
WOMEN
TOILET
C-B175
CORRIDOR
NON/
FOOD&/
SUPPLY
STOR.
C-B162
C-B164
COOLER
C-B173 C O
R R
ID
O
R
CLOSET
CLEANING
C -B
LIFT
C-3
LOCKER
TO
IL
ET
ST
AF
F
C H
AS
E
HELP DESK
COMPUTER C
-B
C-B158
ROOM
WAITING ROOM
C-B136 C-B137
DIETICIAN
C-B138
MOVE
C-B135
DIETICIAN
C-B176
CAFETERIA
PA
PE
R S
TO
R
AG
E
C-B134C-B133
C-B132 C-B131
C-B163
OFFICE OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
ROOM
IMS
FOOD
SERVICE
FOREMEN
C-B142
SUPPLY
C-B143 H.A.C.
C-B141
C B-
CB-26
CORRIDOR
A-B064
STERILIZATION
ETO
SEC
C-B024
O I&
T
OI&T
A-B043
CHIEF
111 SEATS
UP
PR
O
ST
H
ET
IC
S
PROSTHETIC
S
C-B117
D -B
C -B
7A
OFFICE
EDU SVC.OFFICE
EDU SVC.
OFFICE
EDU SVC.OFFICE
EDU SVC.
OFFICE
EDU SVC.
OFFICE
EDU SVC.
STORAGE
OFFICE
EDU SVC.
OFFICE
EDU SVC.
OFFICE
EDU SVC.
OFFICE
EDU SVC.
OFFICE
EDU SVC.
OFFICE
EDU SVC.
OFFICE
EDU SVC.
EDU SVC.
EDU SVC.
SAFETY
MGR.
ADMIN
SAFETY
RADIATION
S.O.
E.M.S.
INDUSTRIAL
HYGIENIST
STORAGE
CANTEEN
DISTRIBUTION
C -B
3A
BREAK ROOM
EB030
C -B
8A
O
FF
IC
E
PR
O
ST
H
ET
IC
S
OFFICE
EB-029A
GIP
COMMMECH
ROOM
A-B025 A-B024
A-B037
OFFICE
A-B101A-B100
A- B1
A-B159
CB-22
LOBBY
CORRIDOR
C B-
C B-
C -3
ROOM
C-1
SPD
C O
R R
ID
O
R C
B-
CB-10
LOBBY
CB-11
LOBBY
CB-41
C-B014A
OI&T TURN-IN
C-B148
C-B159
C-B125
D-B001
OF SRD
QM
CT ROOM
OFFICE
CONTROL RM.
SHAFT
SOILED
EXAM 5
B-B024
EXAM 4
EB-C02
EB-026
EB-028
EB-027
B- B0
A
D R
ES
S.
R M
DR. B-B027
FCIO
DIETITIAN
WAN TEAM
ELEC. EQUIP.
ROOM
COOR
W O
M
EN
CART
OI&T IT STOR
#8-B
#5-B
STAIR
#14-B
MAIN WAREHOUSE
LOGISTICS
LOGISTICS
LOGISTICS
LO
GISTIC
S
LO
GISTIC
S
TRAINING
BLOCK
ROOM
LEAD
WALLS
B-B025
SIMULATOR
BUSINESS AND OTHER USES
10893 SQ FT
BUSINESS AND OTHER USES
ZONE 1IB-02
16267 SQ FT
BUSINESS AND OTHER USES
ZONE 1IB-11
14126 SQ FT
STORAGE OCCUPANCY
ZONE 1IB-01
5996 SQ FT
BUSINESS AND OTHER USES
ZONE 1IB-12
5341 SQ FT
BUSINESS AND OTHER USES
ZONE 1IB-03
13214 SQ FT
AMBULATORY HEALTH CARE
ZONE 1IB-07
5950 SQ FT
BUSINESS AND OTHER USES
ZONE 1IB-08
10541 SQ FT
INDUSTRIAL OCCUPANCY
ZONE 1IB-05
22021 SQ FT
BUSINESS AND OTHER USES
ZONE 1IB-04
22013 SQ FT
BUSINESS AND OTHER USES
ZONE 1IB-03
18009 SQ FT
ZONE 1IB-06
15781 SQ FT
BUSINESS AND OTHER USES
ZONE 1IB-09
18200 SQ FT
BUSINESS AND OTHER USES
ZONE 1IB-10
AR
EA B
AR
EA A
AREA B
AREA A
EP
UNDER
RENOVATION
LC
LC
LC
LC
TC
EX
STAIR #9-B
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
FACP
TOILET
A-B012
FACP
U N
D
ER
C O
N
STR
U C
TIO
N
FHV
STORAGE
OCCUPANCY
BUSINESS
OCCUPANCY
SUITE DESCRIPTIONS
SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SYMBOLS LIST
HORIZONTAL EXIT PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
DATEREVISIONS: NUMBER
DRAFT SOC
FP&C Project Number Project NumberProject Title
Location
Issue Date Checked by Drawn by
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS, LLC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE
FVO KW 36Dwg. of
1557.31
EP
LC
TC
EX
HE
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
SUITE DESIGNATION
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
INDIANAPOLIS, IN
UPDATE STATEMENT OF
CONDITIONS
RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC
1481 W. 10th Street Indianapolis, IN 46202
SPRINKLER / FIRE SMOKE ZONE
VA PLANNING AND ENGINEERING
BASEMENT FLOOR
BUILDING 1
STATEMENT OF CONDITIONS
1SOC-B
583-19-506
NON-RATED SMOKE PARTITION
1/15/2021 6/1/20
APPROVED EQUIVALENCIES
1. MINI-ATRIUM EQUIVALENCY DATED 12-14-10
2. NON-LISTED URETHANE FOAM IN WALLS THAT ARE NOT FIRE OR SMOKE
BARRIER WALLS EQUIVALENCY DATED 8-26-09
3. BUILDING 7, CSR SINGLE MEANS OF EGRESS EQUIVALENCY DATED 13-7-07
4. NON-SPRINKLERED ELEVATOR MACHINE ROOM EQUIVALENCY DATED
12-27-04
5. NO VENTING OF LINEN CHUTES EQUIVALENCY DATED 5-29-96
6. NON-COMPLIANT PROTECTIVE PLATES EQUIVALENCY DATED 4-21-95
7. PASS-THROUGH CABINETS EQUIVALENCY DATED 3-15-94
8. TRAVEL DISTANCE AND COMMON PATH OF TRAVEL DISTANCES ARE
EXCEEDED.
-BASEMENT ZONE 11B-06 EQUIVALENCY DATED 9-6-12
FINAL SOC 9/16/20
DRAFT OUTER BUILDINGS 10/05/20
DRAFT OUTER BUILDINGS 2 12/18/20
1/15/21 UPDATED FINAL SOC
COMPOSITE
FULLY SPRINKLERED
MIXED OCCUPANCY
N
BUILDING 1 BASEMENT
KEY NOTES:
G-1
ELEV. CHASE
DN
UP
UP
UP
UP
WATER SOFTENER
A-B110
WASH
A-B109A
REPAIR
LOBBY
A-B114
SHOP
A-B115
CB-3
CARPENTER
SHOP
A-B121
A-B116 A-B120
A-B108A
A-B117
SUPER-
A-B118 A-B119
OFFICE
A-B040
A-B043
A-B021
TRAINING
C O
R R
ID
O
R
SEC./
A- B0
OFFICE
A-B136
REPAIR ENG.
A-B142 A-B143
A-B148
ROOM
B-B033 B-B045
ROOM
RECEPT.
OFFICE
ROOM
UTILITY
B-B041
OFFICE
B-B036
C O
N
TR
O L
R O
O M
B-B038 ROOM
B-B015
A-B137
C-B067
ROOM
C-B129
STORAGE
C B-
C-B030
MACHINE SHOP
C-B033
C-B075
C-B118 C-B120
C-B091
TOILET
C -B
C-B113A
C-B117A C-B102
WOMEN
C-B103 C-B109
C-B098 C-B095 C-B094
C O
N
TR
O L
C -B
C O
R R
ID
O
R
C O
R R
ID
O
R
C-B092
STOR.
EL
EC
TR
O
N
IC
S
MANUAL
SHIPPING
CB-52
CORRIDOR
CB-55
CORRIDOR C-B063
FIRE EQUIP.
STOR.
MAINT.
ROOM
STAIR #3-B
MECH.
RECEIVING
EQUIP.
AUTOPSY
C-B123
SUITE
C O
R R
ID
O
R
C B-
C
O R
R
ID
O R
R.O. EQUIPMENT
CHIEF
COOLER #1
WALK-IN
C-B145CANTEEN
FREEZER 4
ELEV.
A-B154
R
AM
P U
P
UP
C-B027
RADIATION
OFFICE
SUPER-
ELECTRIC
SHOP
A-B145
VISOR
C-B150
C-B153
A-B045
PARTS
STORAGE
C-B032
STORAGE
FLAMMABLE
LOBBY
VIEWING ROOM
C-B119
BIOMEDICAL
CORRIDOR
C-B071
SVCS.
ENG.
ELEV.
S-11
S-12
ELEV.
P-15
DOCK
LOADING
STAIR #6-B
C-B115
CORRIDOR
STORAGE
A-B138
ELECTRICAL
DN
FIRE
MAINTEN-
ANCE
MAINTEN-
VISOR
SUPER-
FUTURE
CHASE
ROOM
SHAFT
M
EC
H
RAMP UP
A-B123
B- B0
B-B043
OFFICE
WAITING
OF QM
C-1
TOILET
BREAKOUT
A-B081
SHOP
MASONRY
A-B102
CLOSET
CLOSET
A-B104
CLOSET
A-B105
AC SHOP
A-B106
STORAGE
CLERKS
CORRIDOR
CB-7
LOUNGE
A-B071
A-B072
LIFT
CORRIDOR
CB-30
LI
FT LIFT
ELEC.
A-B075
AREA
SUPPLY STORAGE
PLUMBING
ASST.
CHIEF
A-B087
TOILET
WOMEN
A-B084
A-B078
SHOP
SPS STORAGE
STORAGE
A-B080
DECON
A-B067
PREPARATION/
ROOM
A-B062
SCOPE
ETO
ASST. LOG
A-B048
ENVIRONMENTAL
TOILET
FOR QCIS
P-1
DN
O
FF
IC
E
C-B062
C-B055
HELP
UP
DN
DN
R
AM
P
IMS
QCIS/QM
A-B033B
SECTION
CODING
ICRA
A-B018b
QM
A-B017b
SC
AN
N
IN
G
HIMS
O
FF
IC
E
UP
UP
A-B113 OUTDOOR
STORAGE
A-B112
AND WASHDOWN
MAINTENANCE
A-B110
WHEELCHAIR
CB-5
PAINT
A-B125
COLLECT.
DUST
LOBBY
ELECTRICAL
PRINTS
BLUE
MACHINE AND
WELDING SHOP
ANCE
MAINTEN-
VISOR
A-B044
R01
A-B043b
CHIEF
LOG SERVICE
A-B030
P&H COPY
A-B135
BED
A-B141
LOCKSMITH
SERVICE
C O
R R
ID
O
R C
B-
ELECTRICAL
SWITCHGEAR
A-B139
MECHANICAL
ELEC.
A-B147
ST
AI
R
-B
C O
R R
ID
O
R C
B-
TELE.
ROOM
B-B051
CORRIDOR
CB-20
EQUIP RM
TE
LE
R
O O
M
CORRIDOR
B- B0
B-B046
CONTROL
B-B034 B-B044
B-B035
MRI
SOILED
B-B042
SCAN ROOM
B- B0
B-B014
ROOM
TREATMENT
CORRIDOR
CB-11
TREATMENT
AREA WELL
B-B022 B-B023
M&O
OFFICE
C-B065
H.A.C.
C-B040
CHUTE
LINEN
C-B039
C-B037
C O
R R
ID
O
R
C -B
4A
SE
C
C-B030A
ENGINEER
BIOMEDICAL
C-B028
C-B035
C -B
C-B127
C -B
C-B034
C-B144
C-B146 C-B149
FREEZER 2
C-B069
GENERATOR
EMERGENCY
C-B115A
C-B118A
C-B112A
C-B110A
C-B114A
C-B097
C-B110
C-B108
C-B107
C-B093C-B096
MISC.
CORRIDOR
EL
EC
TR
O
N
IC
S
SUPPORT
CLERICAL
C O
R R
ID
O
R
C-B170
C-B064
R O
O M
CANTEEN STORAGE
EQUIP.
FIRE
C-B100
SHAFT
C B-
SWITCHGEAR ROOM
C-B074
SERVICE
CANTEEN
C-B072
SERVICE
CANTEEN
C-B073
ELEC.
ROOM
C-B066
OFFICE
STORAGE STORAGE
EMS
A-B151
TE
LE
. R M
C-B031
REPAIR & DEVELOPMENT
C-B077
RECEIVING
C-B076
CLOSET
C-B151
CHASE 1B
A-B150
MECHANICAL ROOM
TE
LE
. R M
TOILET
ELEV.
P-14
P-13
ELEV.
A- B1
TE
LE
PH
O
N E
R O
O M
MEN
P-16
A-B153
ROOM
ELEC.
ELIGIBILITY
ACCOUNTS &
PATIENTS
A-B155
TOILET
R
AM
P U
P
ONCOLOGY
RECEPT.
B-B029
SUPER-
ELECTRIC
SHOP
A-B145
VISOR
ELECTRICAL
SWITCHGEAR
A-B140
FREEZER 3
C-B152
CONTROL
INGREDIENT
C-B155
CORRIDOR
MANAGEMENT
ST
AI
R
-B
MATERIALS
SUPER-
VISOR
MAINTE-
NANCE
ADMIN.
SUPV.
CB-31
C-B121
VESTIBULE
C-B122
COLD ROOM
ENV. SERV.
C-B124
STORAGE
ENG.
SUPERVISOR
C-B038
CB-2
STORAGE
EQUIP.
ELEV.
SUPPLIES/EQUIPMENT
STORAGE/
A-B001
A-B126
STAIR
ELEV.
ROOM
MECH.
ELECTRICAL
SHOP
A-B144
A-B146
CHUTE
LINEN
TOILET
CB-21
CORRIDOR
EQUIP.
ELEV.C-B104 C-B105 C-B106
C-B099
ANCE
VISOR
SUPER-
S-13
CHASE
C H
AS
E
CHASE
C H
AS
E
C H
AS
E
TOILET
ROOM
B-B028
TO
IL
ET
C O
R R
ID
O
R C
O R
R
ID
O R
C B-
STAIRCASE
ROOM
CONFERENCE
#4-B
ENGINEERING
C-B056
C-B111A
D R
ES
S.
R M
B- B0
D
R
ES
S.
R
M
BREAK
ROOM
B-B047
PACS & MRI
DCS
A-B034
C-2
C O
R R
ID
O
R C
B-
MEN
A-B103
CLEAN EQUIP.
A-B082
SPD
A-B085
SUPPLY
A-B074
CORRIDOR
CB-7
WOMEN
TOILETA-B073
TOILET
MEN
A-B070
EQUIPMENT
SUPER-
VISOR
A-B088
EQ
P.
A- B0
A-B089
STORAGE
ROOM
A-B090
STERILE SUPPLY
A-B079
SERVICE
ENVIRO.
WASH
A-B068
LIFT
SHOP
A-B107
CHIEF
CLERK
PLUMBING
A-B108
A-B109
A-B083
RECEPTION
BULK/
CASE CART
EQUIPMENT
STORAGE
EQUIPMENT
A-B069 LO
U
N G
E A-
B0
A-B061
DECONTAMINATION
STERILIZATION
A-B066
ASSEMBLY/
STERILIZATION
A-B065
CART WASH
A-B077
MEN
TOILET
SPD
DECONTAMINATION
A-B063
C H
AS
E
CHIEF, LOG
A-B042
A-B
A-B
WORK
ROOM
SERVICE
CB-9
CORRIDOR
OFFICE
CLERK
A-B156 A-B157
WOMEN
A-B042
A-B041
TEAM
ROOM
ACOS
ELEV.
UP
LO
G
IS
TI
C S
C -B
C-B
C-B058
C-B055
C -B
CONF RM
RAMP
A-B050
OFFICE
FOODSERVICE
PROSTHETICS
A-B033d
CODERS
O
FF
IC
E
O
FF
IC
E
A- B0
PE
T
SC
AN
N
ER
CORRIDOR
A-B016
A-B032
ROOM
C O
R R
ID
O
R
A-B023
QM
R01
A- B0 d
A- B0 c
HIMS
CB-17
ELEC. ROOM
A- B0
C
ELECTRICAL
A-B031
WAITING
TR
AN
SC
R
IP
TI
O N
G-2
DW-1
CLOSET
CHASE
STAIR
#12-B
A-B033A
C B-
12 LEAD
O
FF
IC
E
FISCAL
A-B036
FISCAL
A-B038
FISCAL
A-B039
EQUIPMENTA-
B0 a
Q M
A-B017c A-B017a
ST
O
R
ASST CH
HIMS
CHIEF
CONTROL
A-B011B
R
EA
D
IN
G A-
B0
A
C
LE
AN
A-
B0
U
PT
AK
E
A- B0
U
PT
AK
E
A- B0
U
PT
AK
E
A- B0
U
PT
AK
E
A- B0
U
PT
AK
E
A- B0
SOILED
UTILITY CORRIDOR
CB-00A-B004
PET/CT
A-B011C
A-B011D
TOILET
A-B014C
O R
R
ID
O R
C B-
WAITING
A-B002
TOILET
A-B013
R
EC
P.
A-
B0
A
ROOM
A-B003B
WORK
STAFF
TREATMENT
PLANNING
B-B009
B-B010
OFFICE
B-B011
ONCOLOGY
RADIATION
CHIEF
B-B008
CHIEF
PHYSICIST
TOILET
WOMEN
B-B031 B-B030
TOILET
MEN
MANAGER
B-B007
NURSES
B-B005 B-B004
EXAM3 EXAM2
B-B003
EXAM1
B-B002
WAITING ROOM
B-B001
B-B020
TOILET
B-B021
BREAK ROOM
B-B017
HEALTH TECH
B-B016 MECH.
ROOM
B-B018
B-B019
CLOSET
JANITOR
B-B026
B-B012
OFFICE
RESIDENTS'
UTILITY
TOILET
HANDICAP
SH
AF
T
C-B059
OFFICE
NEW CONF.
ROOM
B-B006
B-B024
C O
R R
ID
O
R
CB-3 C
O
R R
ID
O
R
B-B013
ROOM
KLYSTRON
ENG. LOCKSMITH
ENG.
SERVICE
AUDITORIUM
A-B065A
CB-25
COMMON
OI&T PC STOR./DEVP.
IMS
OI&T SUPV
IMS
C-B029
OI&T MGR
C-B030
OI&T ASSIST.
IMS
C -B
OI&T RECP.&
PRINT AREA
C-B025
IMS
OI&T FCIO
C-B026
OI&T SYSTEMS
C-B022
TELECOM
LO
C
KE
R
C-B130
CORRIDOR
C -B
TO
IL
ET
C-B126
C-B174
WOMEN
TOILET
C-B175
CORRIDOR
NON/
FOOD&/
SUPPLY
STOR.
C-B162
C-B164
COOLER
C-B173 C O
R R
ID
O
R
CLOSET
CLEANING
C -B
LOCKER
TO
IL
ET
ST
AF
F
C H
AS
E
HELP DESK
COMPUTER C
-B
C-B158
ROOM
WAITING ROOM
C-B136 C-B137
DIETICIAN
C-B138
MOVE
C-B135
DIETICIAN
C-B176
CAFETERIA
PA
PE
R S
TO
R
AG
E
C-B134C-B133
C-B132 C-B131
C-B163
OFFICE OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
ROOM
IMS
FOOD
SERVICE
FOREMEN
C-B142
SUPPLY
C-B143 H.A.C.
C-B141
C B-
CB-26
CORRIDOR
A-B064
STERILIZATION
ETO
SEC
C-B024
O I&
T
OI&T
A-B043
CHIEF
111 SEATS
UP
PR
O
ST
H
ET
IC
S
PROSTHETIC
S
C-B117
C -B
7A
OFFICE
EDU SVC.OFFICE
EDU SVC.
OFFICE
EDU SVC.OFFICE
EDU SVC.
OFFICE
EDU SVC.
OFFICE
EDU SVC.
STORAGE
OFFICE
EDU SVC.
OFFICE
EDU SVC.
OFFICE
EDU SVC.
OFFICE
EDU SVC.
OFFICE
EDU SVC.
OFFICE
EDU SVC.
OFFICE
EDU SVC.
EDU SVC.
EDU SVC.
SAFETY
MGR.
ADMIN
SAFETY
RADIATION
S.O.
E.M.S.
INDUSTRIAL
HYGIENIST
STORAGE
CANTEEN
C -B
8A
O
FF
IC
E
PR
O
ST
H
ET
IC
S
COMMMECH
ROOM
A-B025 A-B024
A-B037
OFFICE
A-B101A-B100
A- B1
A-B159
CB-22
LOBBY
CORRIDOR
C B-
C B-
C -3
ROOM
C-1
SPD
C O
R R
ID
O
R C
B-
CB-10
LOBBY
CB-11
LOBBY
C-B148
C-B125
OF SRD
QM
CT ROOM
OFFICE
CONTROL RM.
SHAFT
SOILED
EXAM 5
B-B024
EXAM 4
B- B0
A
D R
ES
S.
R M
DR. B-B027
FCIO
DIETITIAN
ELEC. EQUIP.
ROOM
COOR
W O
STAIR
#14-B
LOGISTICS
LOGISTICS
LOGISTICS
LO
GISTIC
S
LO
GISTIC
S
TRAINING
BLOCK
ROOM
LEAD
WALLS
B-B025
SIMULATOR
BUSINESS AND OTHER USES
5996 SQ FT
BUSINESS AND OTHER USES
ZONE 1IB-12
5341 SQ FT
BUSINESS AND OTHER USES
ZONE 1IB-03
13214 SQ FT
AMBULATORY HEALTH CARE
ZONE 1IB-07
5950 SQ FT
BUSINESS AND OTHER USES
ZONE 1IB-08
10541 SQ FT
INDUSTRIAL OCCUPANCY
ZONE 1IB-05
22021 SQ FT
BUSINESS AND OTHER USES
ZONE 1IB-04
22013 SQ FT
BUSINESS AND OTHER USES
ZONE 1IB-03
18009 SQ FT
ZONE 1IB-06
AR
EA B
AR
EA A
AREA B
AREA A
EP
UNDER
RENOVATION
LC
LC
EX
STAIR #9-B
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
FACP
TOILET
A-B012
FHV
SUITE DESCRIPTIONS
SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SYMBOLS LIST
HORIZONTAL EXIT PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
DATEREVISIONS: NUMBER
DRAFT SOC
FP&C Project Number Project NumberProject Title
Location
Issue Date Checked by Drawn by
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS, LLC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE
FVO KW 36Dwg. of
1557.31
EP
LC
TC
EX
HE
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
SUITE DESIGNATION
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
INDIANAPOLIS, IN
UPDATE STATEMENT OF
CONDITIONS
RICHARD L. ROUDEBUSH VAMCRichard L. Roudebush VAMC
1481 W. 10th Street Indianapolis, IN 46202
SPRINKLER / FIRE SMOKE ZONE
VA PLANNING AND ENGINEERING
BASEMENT FLOOR
BUILDING 1
STATEMENT OF CONDITIONS
1SOC-BA
583-19-506
NON-RATED SMOKE PARTITION
1/15/2021 6/1/20
APPROVED EQUIVALENCIES
1. MINI-ATRIUM EQUIVALENCY DATED 12-14-10
2. NON-LISTED URETHANE FOAM IN WALLS THAT ARE NOT FIRE OR SMOKE
BARRIER WALLS EQUIVALENCY DATED 8-26-09
3. BUILDING 7, CSR SINGLE MEANS OF EGRESS EQUIVALENCY DATED 13-7-07
4. NON-SPRINKLERED ELEVATOR MACHINE ROOM EQUIVALENCY DATED
12-27-04
5. NO VENTING OF LINEN CHUTES EQUIVALENCY DATED 5-29-96
6. NON-COMPLIANT PROTECTIVE PLATES EQUIVALENCY DATED 4-21-95
7. PASS-THROUGH CABINETS EQUIVALENCY DATED 3-15-94
8. TRAVEL DISTANCE AND COMMON PATH OF TRAVEL DISTANCES ARE
EXCEEDED.
-BASEMENT ZONE 11B-06 EQUIVALENCY DATED 9-6-12
FINAL SOC 9/16/20
DRAFT OUTER BUILDINGS 10/05/20
DRAFT OUTER BUILDINGS 2 12/18/20
1/15/21 UPDATED FINAL SOC
AREA - A
FULLY SPRINKLERED
MIXED OCCUPANCY
N
BUILDING 1 BASEMENT
A-B021
TRAINING
C O
R R
ID
O
R
SEC./
A- B0
C-B067
ROOM
C-B129
STORAGE
C B-
C-B030
MACHINE SHOP
C-B033
C-B075
C-B118 C-B120
C-B091
TOILET
C-B109
C-B098 C-B095 C-B094
C O
N
TR
O L
C -B
C O
R R
ID
O
R
C-B092
STOR.
EL
EC
TR
O
N
IC
S
MANUAL
SHIPPING
CB-52
CORRIDOR
CB-55
CORRIDOR C-B063
FIRE EQUIP.
STOR.
MAINT.
ROOM
STAIR #3-B
MECH.
RECEIVING
AUTOPSY
C-B123
SUITE
C O
R R
ID
O
R
C B-
C
O R
R
ID
O R
CHIEF
COOLER #1
WALK-IN
C-B145CANTEEN
FREEZER 4
ELEV.
A-B154
R
AM
P U
P
#1-B
S-5
TELE. ROOM
P-4 S-6
P-10
LOBBY
D-B009
#7-B
FIRE PUMP
MECHANICAL
ROOM
C -B
C O
R R
ID
O
R
LOBBY
EXERCISE
C B-
MEN
LOCKERS
C-B006
CHUTE
C-B004
LINEN
MECH.
C -B
LOBBY
C-B027
MECH. ROOM
C-B150
C-B153
CB-46
C-B156
CLEAN EQUIP.
SEAMSTRESS
EFFECTS
GOODWILL
FO
R
M
AN
EM
S
G
EN
C H
U
TE
LI
N
EN
STORAGE
C-B19…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .