Attachment P - Bldg. 765 Proposed Layout.pdf
PDF 203 KB Posted
- Solicitation number
- W912DY26R1103
About this file
This document is an architectural drawing set for Camp Carroll - Building 765, prepared by the US Army Corps of Engineers. The drawings depict the ground floor plan and roof plan of a facility featuring multiple rooms and spaces including a vestibule, restroom, office, communication room, mechanical room, storage, and utility closet. The ground floor plan indicates dimensions, door specifications (including high-movement doors and frames with 2150 x 2150 and 2750 x 2750 openings), flooring treatments, and interior partitions constructed of painted concrete masonry units. Key features include concrete slabs on grade with sealer-hardener, resilient flooring, one-hour rated fire-barrier protection with fire stops at all penetrations, yellow painted floor stripes, utility fixtures (eyewash and safety shower), an equipment pad, and drainage slope details. The roof plan shows a 2:12 slope configuration, metal gutters and downspouts with gutter expansion joints, plumbing vents with neoprene boot flashing, louver openings, and duct penetrations coordinated with mechanical systems. The room schedule provided indicates various space designations with corresponding areas measured in square feet. Construction materials specified include painted concrete masonry unit interior partitions, stucco rendering over CMU, steel coiling doors (insulated), fire-retardant plywood on two walls, and resilient flooring with STC-45 sound transmission class ratings.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A-201
A-200
A-200
A-201
MECH ROOM
COMM
ROOM
OFFICE
RESTROOM
V E
S T
IB
U
L E
STORAGE
M.O.
14150
101C 4
T
Y P
400 (TYP)
M .O
M .O
M .O
M .O
400 (TYP) 2650
D
101B
101A
M.O.
1000 600
M.O.
2750 3450
M .O
M.O.
M .O
(DOOR: 2750 X 2750)
PAINTED CMU INTERIOR
PARTITIONS (TYP)
CONCRETE APRON 7350 X 1900,
SEE STRUCTURAL PLANS
CONCRETE STOOP
(2150 X 1500)
CONCRETE STOOP
(3650 X 1500)
EQUIPMENT PAD (TYP)
(D O
O R
X
A-300
A-300
A-301
A-301
W1W1
W
W
UTILITY
CLOSET
101A
SPLASH BLOCK
(TYP OF 5)
PAINTED
BOLLARDS
(TYP FOR 4)
PAINTED
BOLLARDS
(TYP FOR 2)
NOTE 1
NOTE 1
NOTE 1
FLOOR ELEV. = 0
LOUVERS
OPENING ABOVE
(NOTE 1)
DUCT
PENETRATION
(NOTE 1)
LOUVER
OPENING ABOVE
(NOTE 1)
CJ
CJ
CJ
CJ
A-602
F.D. CONCRETE EQUIPMENT PAD
CJ
CJ
CJCJ
CJ
EYEWASH/ SAFETY-SHOWER
COORDINATE WITH MECH
FLOOR TRANSITION STRIP
A-501
A-501
SLOPE FLOOR
TO DRAIN
HM DOORS
AND FRAMES
20MM PAINTED FIRE-
RETARDANT PLYWOOD
ON TWO WALLS
UTILITY
SINK
STEEL COILING
DOOR
PAINTED
BOLLARDS
(TYP FOR 2)
500 SQUARE SS
ACCESS PANEL
HM
DOOR
PAINTED
CMU
STC-45
RESILIENT
FLOORING
HM
DOOR
STUCCO
RENDERING
OVER CMU
H M
D
O O
R
PAINTED (YELLOW)
FLOOR STRIPES
STEEL, INSULATED
COILING DOOR
DOOR ACTUATOR
PAINTED
CMU (TYP)
CONCRETE SLAB ON GRADE
WITH SEALER - HARDENER
HM
DOOR
STC-45
1-HR RATED
FIRE-BARRIER.
FIRE STOP ALL
PENETRATIONS
A-400
REFER TO CIVIL
DRAWING FOR
ACTUAL ELEVATION
CJ CJ
CJ
CJ
CJ
FE
FE
2:12 SLOPE2:12 SLOPE
2:12 SLOPE 2:12 SLOPE
GUTTER AND
DOWNSPOUTS (TYP)
STEEL STANDING-SEAM
ROOFING (TYP)
PLUMBING VENT -
FLASH WITH NEOPRENE
BOOT. MATCH PROFILE
OF ROOF PANELS.
ALUM AIR TERMINALS
(SEE ELEC)
GUTTER
EXPANSION JOINT
GUTTER
EXPANSION JOINT
METAL GUTTERS
AND DOWNSPOUTS
STANDING SEAM
METAL ROOF
METAL RIDGE
FLASHING
GUTTER AND DOWNSPOUT
SEE 2/A-500
ONE HOUR FIRE WALL
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
F A
R E
A S
T D
IS
T
R
IC
T U
N
IT
C A
M P
C A
R R
O L L K
O R
E A
F Y
U
M M
C A
P N
B -8
R
E P
L A
C E
M E
N T
W A
R E
H O
U S
E A
N D
O G
A S
C Y
L
IN
D E
R S
S T
O R
A G
E Y
A R
D
US Army Corps of Engineers ®
SHEET ID
1 2 3 4 5
D
C
B
A
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
A P
P R
O V
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
T B
D
6 7 8 9 10
E
F
G
100%, READY TO ADVERTISE
S C
A L E
W U
M D
UNLESS NOTED OTHERWISE,
DIMENSIONS SHOWN ARE IN MILLIMETERS
A-100
B-832
E A
T A
W F
IK
J M
K O
E N
IG
A J H
A Y
N E
S
J U
N E
G R
O U
N D
F L O
O R
A N
D R
O O
F P
L A
N S
C C
H A
M B
E R
L
IN
SCALE = 1 : 501
GROUND FLOOR PLAN N
NOTES:
1. COORDINATE EXACT LOCATIONS OF PIPING AND DUCT
PENETRATIONS WITH MECHANICAL.
2. COORDINATE EXACT SIZES AND LOCATIONS OF LOUVERS WITH
MECHANICAL CONTRACTOR.
3. DIMENSIONS ARE TO FACE OF MASONRY UNITS AND ARE
EXCLUSIVE OF STUCCO AND PLASTER FINISHES.
4. FOR ABBREVIATIONS AND SYMBOLS REFER TO G-003 &G-004.
5. FOR FIRE EXTINGUISHER LOCATION REFER TO DRAWING F-101.
6. FOR CONCRETE SLAB ON GRADE, EXTERIOR CONCRETE DOOR
PADS , FLOOR SLOPES AND INTERIOR EQUIPMENT PAD SIZES AND
DETAILS , REFER TO STRUCTURAL DRAWINGS.
ROOM SCHEDULE (W/ AREAS)
NUMBER NAME
NET AREA
(SQ M)
100 VESTIBULE 5 m²
101 STORAGE 113 m²
101A UTILITY CLOSET 3 m²
102 OFFICE 18 m²
103 RESTROOM 8 m²
104 COMM ROOM 8 m²
105 MECH ROOM 11 m²
GROUND FLOOR TOTAL GROSS AREA : 193 m²
SCALE = 1 : 502
ROOF PLAN N
43211
1:50
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E joseph.e.mandell.civ@army.mil Text Box
CAMP CARROLL - BLDG 765
joseph.e.mandell.civ@army.mil Rectangle joseph.e.mandell.civ@army.mil Rectangle joseph.e.mandell.civ@army.mil Rectangle joseph.e.mandell.civ@army.mil Rectangle joseph.e.mandell.civ@army.mil Rectangle joseph.e.mandell.civ@army.mil Rectangle joseph.e.mandell.civ@army.mil Rectangle joseph.e.mandell.civ@army.mil Text Box M2085M joseph.e.mandell.civ@army.mil Text Box M2085M joseph.e.mandell.civ@army.mil Text Box M2085M joseph.e.mandell.civ@army.mil Text Box M2085M joseph.e.mandell.civ@army.mil Text Box M2085M joseph.e.mandell.civ@army.mil Text Box M2085M joseph.e.mandell.civ@army.mil Text Box M2085M joseph.e.mandell.civ@army.mil Rectangle joseph.e.mandell.civ@army.mil Rectangle joseph.e.mandell.civ@army.mil Text Box M2085M joseph.e.mandell.civ@army.mil Text Box M2085M joseph.e.mandell.civ@army.mil Rectangle joseph.e.mandell.civ@army.mil Text Box
BEN00070
joseph.e.mandell.civ@army.mil Rectangle joseph.e.mandell.civ@army.mil Rectangle joseph.e.mandell.civ@army.mil Text Box E0063
File details come from the government source that posted it. Updated .