- 80GSFC23R0009FRFP
About this file
This document is an attachment to a solicitation requesting proposed enhancements from offerors for the Wallops Range Contract (WRC). The solicitation is issued by the National Aeronautics and Space Administration Goddard Space Center as number 80GSFC23R0009FRFP.
The attachment instructs offerors to propose enhancements to the contract's performance requirements using precise Performance Work Statement terminology. Offerors must identify the specific section of the contract schedule or attachment that contains the existing performance requirement, then clearly define their proposed enhancement. Examples provided demonstrate how to specify improved response times and increased performance over stated requirements for cleaning, decontaminating, and inspecting a test facility within set timeframes.
View the file
Other files for this federal contract opportunity
Show all 50
Wallops Range Contract (WRC) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT N
CONTRACTOR PROPOSED ENHANCEMENTS
RFP 80GSFC23R0009
CONTRACT TBD
Contract TBD Attachment N
CONTRACTOR PROPOSED ENHANCEMENTS
In accordance with the Section H clause entitled, Contractor Proposal Enhancements, and the Contractor’s proposal submitted in response to Request for Proposal (RFP) 80GSFC23R0009 for the Wallops Range Contract (WRC), the Contractor shall perform the following enhancement(s), which are over and above the requirements specified in the contract terms and conditions, Statement of Work, Specifications, and other contract attachments.
1.
2.
3.
Offeror instructions: Insert your proposed enhancement(s) in Performance Work Statement (PWS) terminology using precise terms and clear/concise wording. Identify the current contract performance requirement specified in contract schedule and/or contract attachment (e.g., Attachment A, Statement of Work, Section 5.2.1 or Attachment B, Specification, Section 6.2, etc.)
and then clearly define the proposed enhancement in PWS terminology.
Examples:
1. Improved Response Time
Contract Requirement – Attachment A, Statement of Work (SOW), Section 5.2.1: The Contractor shall respond to a routine service call within 4 business hours (time to first response), resolve the problem within 3 work days, and notify the user of completion within 4 hours of service call closure.
Contractor Enhancement – The Contractor shall respond to a routine service call within 3 business hours (time to first response), resolve the problem within 2 work days, and notify the user of completion with 2 hours of service call closure.
2. Increased Performance
Contract Requirement – Attachment B, Specification, Section 6.2: The Contractor shall clean, decontaminate, and inspect the test facility within 24 hours of test completion.
Contractor Enhancement – Attachment B, Specification, Section 6.2 – The Contractor shall clean, decontaminate, and inspect the test facility within 18 hours of test completion.