ATTACHMENT J11 Cathodic Protection.docx

DOCX document 666 KB Posted

Attached to
Operation and Maintenance of Pearl Harbor Inactive Vessels
Solicitation number
N00024-21-R-4204
Issued by

About this file

This document contains four inspection guidelines forms for cathodic protection systems on inactive vessels. The forms provide guidance on periodic inspections of anodes, hull potentials, power supply outputs, reference cells, bonding cables, and other cathodic protection components. Inspections are to be conducted quarterly and any discrepancies recorded. The related federal contract opportunity is solicitation number N00024-21-R-4204 for operation and maintenance of Pearl Harbor inactive vessels. Proposals are due by April 7, 2022 for this contract with the Department of the Navy Naval Sea Systems Command.

View the file

Other files

File Type Posted
Attachment J-1 Pre-Proposal Information Form 4.21.22.pdf PDF
Exhbt C - Past Performance Questionnaire Rev 1.docx DOCX document
Attachment J-1 Rev 1 19Apr22.pdf PDF
ATTACHMENT J-4 - Tank Soundings Template.xls XLS spreadsheet
N00024-21-R-4204 Amendment 4.pdf PDF
N00024-21-R-4204 RFP Amendment 3.pdf PDF
ATTACHMENT J15 Arrival Inspection.docx DOCX document
Pearl_RFP_3.4.2022_Solicitation_Amendment_1.pdf PDF
ATTACHMENT J14 Integrity Inspection (1).docx DOCX document
Pearl_RFP_3.7.2022_Solicitation_Amendment_2.pdf PDF
Exhbt C - Past Performance Questionnaire.docx DOCX document
Attachment J-1 Pre-Proposal Information Form.xlsx XLSX spreadsheet
ATTACHMENT J20 QUALITY ASSURANCE PLAN.pdf PDF
Attachment J-2 Cost Element Summary Spreadsheets Pearl Harbor.xlsx XLSX spreadsheet
CDRL53-54 Pearl Harbor.pdf PDF
ATTACHMENT J21 DD254 (PEARL HARBOR).pdf PDF
CDRL05_08.pdf PDF
Pearl_Harbor_RFP_3.4.2022_Base_Solicitation.pdf PDF
CDRL37_40 Pearl Harbor.pdf PDF
ATTACHMENT J17 Fire Extinguisher Log.docx DOCX document
ATTACHMENT 12 Dehumidification.docx DOCX document
ATTACHMENT J9 VEHICLES.xls.xlsx XLSX spreadsheet
CDRL13-16 Pearl Harbor.pdf PDF
CDRL25-28 Pearl Harbor.pdf PDF
ATTACHMENT J16 Security Report.doc DOC document
ATTACHMENT J4 SAFE STOWAGE CHECK OFF LISTS.doc DOC document
ATTACHMENT 10 Tools and Materials Pearl Harbor (1).xlsx XLSX spreadsheet
ATTACHMENT J8 GFE from Navy ERP.xls.xlsx XLSX spreadsheet
CDRL09_12 Pearl Harbor.pdf PDF
CDRL41_44 Pearl Harbor.pdf PDF
ATTACHMENT J6 History Folder Index (1).docx DOCX document
CDRL45-48 Pearl Harbor.pdf PDF
ATTACHMENT J7 Janitorial Task and Frequency Chart.xlsx.xlsx XLSX spreadsheet
ATTACHMENT J22 INACTSHIPMAINTO Pearl Harbor Organizational Chart.docx DOCX document
CDRL33_36 Pearl Harbor.pdf PDF
CDRL01_04 Pearl Harbor.pdf PDF
ATTACHMENT J5 RRWO.docx DOCX document
CDRL21-24 Pearl Harbor.pdf PDF
CDRL49-52 Pearl Harbor.pdf PDF
ATTACHMENT J19 PCB Inventory.doc DOC document
Exhbt B - Past Performance Data.docx DOCX document
ATTACHMENT J3 VESSELS.xls.xls XLS spreadsheet
CDRL29-32 Pearl Harbor.pdf PDF
ATTACHMENT J18 Mooring_Security.xlsx XLSX spreadsheet
CDRL17-20 Pearl Harbor.pdf PDF
ATTACHMENT J13 FIRE FLOOD INS.docx DOCX document
ATTACHMENT J-23 List of Key Personnel.docx DOCX document
Show all 47

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Periodicity:

Spec Code:

Berthed At:

Quarter:

NSTM 50 INSPECTION GUIDELINES

CP1

Insp Date:

TDL

Remarks N/A

NO

YES

Description Item Power supply readings have been taken and recorded and are satisfactory.

System has been checked for shorts and opens and none were found.

Have all other discrepancies been reported? If not report them here.

C/P Rectifier

1. Annode Type Installed:

2. Number of Annodes:

3. System Arrangements:

4. Time:

5. Tide:

6. Hull Potential (high):

6a. Hull Potential (low):

7. Power Supply Output (volts):

7a. Power Supply Output (amps):

8. Ag/AgCI Reference Cell Potential: MV:

9. Ships and Floats Moored together have at least 2 Bonding Straps Each:

10. Wetted Area:

FWD Draft:

AFT Draft:

List:

Comments:

Inspector Inspector Inspection Manager

Attachment 10 NSTM 50 INSPECTION GUIDELINES - Descrepancy Listing Spec Code:

Line Item # Location Discrepancy Discovery Dt Correction Dt

Berthed At:

Quarter:

NSTM 50 INSPECTION GUIDELINES

CP2

Insp Date:

TDL

Remarks N/A

NO

YES

Description Item Take and record hull potential readings every 50 feet and record. All readings fall within the range of 0.8 to 1.2 volt range.

Current readings to each anode have been checked and are normal? Record readings.

Are support cords for anodes taking strain off cable?

Reference cell has been checked against shop standard cell and is satisfactory.

Potentiometer-voltmeter has been checked against a standard Weston cell or a battery with a known voltage and is within specifications or adjustments have been made to bring within specs.

Have all other discrepancies been reported? If not report them here.

C/P Potential

1. Annode Type Installed:

2. Number of Annodes:

3. System Arrangements:

4. Time:

5. Tide:

6. Hull Potential (high):

6a. Hull Potential (low):

7. Power Supply Output (volts):

7a. Power Supply Output (amps):

8. Ag/AgCI Reference Cell Potential: MV:

9. Ships and Floats Moored together have at least 2 Bonding Straps Each:

10. Wetted Area:

FWD Draft:

AFT Draft:

List:

Comments:

Inspector Inspector Inspection Manager Cathodic Protection Anode Results Number Cathodic Protection Hull Potential Results Output Number Output Number Output Number Output Number Hull Reading Number Number Number Hull Reading Hull Reading

Line Item # Location Discrepancy

Berthed At:

Quarter:

NSTM 50 INSPECTION GUIDELINES

CP3

Insp Date:

TDL

Remarks N/A

NO

YES

Description Item Check power supply ammeters and voltmeters against a suitable calibrated meter. Were results within specifications ?

Remove dust and debris from power supply enclosures. Is the general condition satisfactory ?

(Automatic hull potential control only) Check reference electrode on the unit against a standard cell. Is the error 0.05 volts or less compared to standard silver-silver chloride reference cell?

Clean all exposed terminal connection, ship bonds, rectifier connections, ground return connections by sandpapering. Have all listed connections been sandpapered and in good condition?

All ships in nest have CP installed.

Are there 2 bonding cables installed, one fwd and one aft between ships. (Ships over 400 foot long require a third bonding cable in the middle) Have all other discrepancies been reported? If not report them here.

C/P System Check

1. Annode Type Installed:

2. Number of Annodes:

3. System Arrangements:

4. Time:

5. Tide:

6. Hull Potential (high):

6a. Hull Potential (low):

7. Power Supply Output (volts):

7a. Power Supply Output (amps):

8. Ag/AgCI Reference Cell Potential: MV:

9. Ships and Floats Moored together have at least 2 Bonding Straps Each:

10. Wetted Area:

FWD Draft:

AFT Draft:

List:

Comments:

Inspector Inspector Inspection Manager

Line Item # Location Discrepancy

Berthed At:

Quarter:

NSTM 50 INSPECTION GUIDELINES

CP4

Insp Date:

TDL

Remarks N/A

NO

YES

Description Item (Automatic hull pontential control only) Record the date the reference electrode was installed. Does the reference electrode require replacement ? (must be replaced every 5 years) Have all other discrepancies been reported? If not report them here.

C/P Electrode (Auto Systems)

1. Annode Type Installed:

2. Number of Annodes:

3. System Arrangements:

4. Time:

5. Tide:

6. Hull Potential (high):

6a. Hull Potential (low):

7. Power Supply Output (volts):

7a. Power Supply Output (amps):

8. Ag/AgCI Reference Cell Potential: MV:

9. Ships and Floats Moored together have at least 2 Bonding Straps Each:

10. Wetted Area:

FWD Draft:

AFT Draft:

List:

Comments:

Inspector Inspector Inspection Manager Cathodic Protection Anode Results Number Cathodic Protection Hull Potential Results Output Number Output Number Output Number Output Number Hull Reading Number Number Number Hull Reading

Line Item # Location Discrepancy