This document is an Attachment 'F' from Detroit Metropolitan Wayne County Airport (DTW) for Request for Proposal (RFP) #240757, specifically detailing concession locations within the McNamara Terminal. The attachment provides detailed floor plans and utility information for three separate commercial spaces: Space 3-1A/3-1B (2,680 S.F.), Space 8-2A (762 S.F.), and Space L-15 (3,620 S.F.), all located in Concourse A. These spaces are part of a Phase 4 Food & Beverage (F&B) opportunity, with each location including specific details about available utilities such as electricity, water, sanitary systems, and telecommunications.
The spaces are configured with various existing infrastructure elements like water heaters, sinks, drains, and electrical panels. Each location has unique electrical configurations, with power sources ranging from 100-125 AMP panels and varying voltage specifications. The documents emphasize that all information is for reference only, and potential tenants must field verify all conditions prior to construction. The spaces are positioned near gate holdrooms and the concourse, with proximity to moving walkways and other terminal infrastructure. The RFP indicates these are tenant improvement opportunities with spaces to be developed according to the winning bidder's specific requirements.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
EP-A
EP-B
NOT TO SCALE
Area of work
Space 3-1A / 3-1B - Concourse A 2,680 S.F.
Concourse
Space 3-1A Gate A20 Holdroom
Exterior windows
McNamara Terminal - Key Plan
AVAILABLE UTILITIES (B)
ELECTRICITY
PANEL EP-B:
400 AMP DOWNSIZED
TO 300 AMP / 84
BREAKER SPACES
3-PHASE
VOLTAGE
120/ 208V
(112.5 KVA
TRANSFORMER /
200A / 480V)
WATER AVAILABLE BELOW
GAS N/A
SANITARY AVAILABLE BELOW
CFM BUILDING AIR
TELECOM/DATA AVAILABLE
GENERAL NOTES:
1. ALL INFORMATION SHOWN IS FOR REFERENCE
ONLY. ALL CONDITIONS MUST BE FIELD
VERIFIED BY TENANT PRIOR TO
COMMENCEMENT AND ISSUANCE OF
CONSTRUCTION DRAWINGS.
2. ALL CONSTRUCTION AND FINISHES FOR ANY
ASSIGNED SPACE TO BE PROVIDED BY TENANT.
KEY:
TBD = TO BE DETERMINED / LOCATED BY TENANT
N/A = NOT AVAILABLE FOR THIS SPACE
Concession Locations McNamara Terminal
ATTACHMENT 'F'
Space 3-1B
N
AVAILABLE UTILITIES (A)
ELECTRICITY
PANEL EP-A:
100 AMP / 42
BREAKER SPACES
3-PHASE
VOLTAGE 120/208V
WATER AVAILABLE BELOW
GAS N/A
SANITARY AVAILABLE BELOW
CFM BUILDING AIR
TELECOM/DATA AVAILABLE
EXISTING
WATER HEATER
PRIOR ELEC.
WASHER/DRYER
EXISTING SINK
WITH DRAIN
EXISTING COMMON
DRAINS / FOOTSINK
(WATER)
EXISTING
WATER METER
EXISTING
WATER METER
EXISTING SINK &
FLOOR DRAINS
DIMENSIONS SHOWN ARE FOR
GENERAL PURPOSES ONLY.
DIMENSIONS MUST BE
CONFIRMED BY ENTITY
ENGAGING IN OPPORTUNITY
PLANNING AND DEVELOPMENT.
Package 1
Attachment F - LODs DTW Phase 4 F&B - RFP #240757
AutoCAD SHX Text
TERMINAL BUILDING
AutoCAD SHX Text
CONCOURSE A
AutoCAD SHX Text
WEST CONCOURSE
AutoCAD SHX Text
CONCOURSE B
AutoCAD SHX Text
CONCOURSE C
AutoCAD SHX Text
EAST CONCOURSE
EP
EP
TRAN.
NOT TO SCALE
Area of work
Space 8-2A - Concourse A 762 S.F.
Gate A61 Holdroom
Concourse
McNamara Terminal - Key Plan
Concession Locations McNamara Terminal
ATTACHMENT 'F'
Space 8-2A
N
AVAILABLE UTILITIES
ELECTRICITY
400 AMP DOWNSIZED
TO 300 AMP / 84
BREAKER SPACES
3-PHASE
VOLTAGE
120/208V
(112.5 KVA
TRANSFORMER 480V
/ 200 AMP)
WATER AVAILABLE ABOVE
GAS N/A
SANITARY AVAILABLE BELOW
CFM BUILDING AIR
TELECOM/DATA AVAILABLE
GENERAL NOTES:
1. ALL INFORMATION SHOWN IS FOR REFERENCE
ONLY. ALL CONDITIONS MUST BE FIELD
VERIFIED BY TENANT PRIOR TO
COMMENCEMENT AND ISSUANCE OF
CONSTRUCTION DRAWINGS.
2. ALL CONSTRUCTION AND FINISHES FOR ANY
ASSIGNED SPACE TO BE PROVIDED BY TENANT.
KEY:
TBD = TO BE DETERMINED / LOCATED BY TENANT
N/A = NOT AVAILABLE FOR THIS SPACE
EXISTING
WATER HEATER
EXISTING WATER
& DRAIN
EXISTING
JAN. SINK
DIMENSIONS SHOWN ARE FOR
GENERAL PURPOSES ONLY.
DIMENSIONS MUST BE
CONFIRMED BY ENTITY
ENGAGING IN OPPORTUNITY
PLANNING AND DEVELOPMENT.
Package 1
Attachment F - LODs DTW Phase 4 F&B - RFP #240757
AutoCAD SHX Text
TERMINAL BUILDING
AutoCAD SHX Text
CONCOURSE A
AutoCAD SHX Text
WEST CONCOURSE
AutoCAD SHX Text
CONCOURSE B
AutoCAD SHX Text
CONCOURSE C
AutoCAD SHX Text
EAST CONCOURSE
A3-479
A3-483BA3-483A A3-483C
A3-479FREE
Area of work
Space L-15 - Concourse A
3,620 S.F. NNOT TO SCALE
Concourse
Gate A43 Holdroom Space L-16
McNamara Terminal - Keyed Plan
AVAILABLE UTILITIES
ELECTRICITY (3 SOURCES)
POWER (1)
125A PANEL,
100A MAIN BREAKER
208-120 VOLTS
POWER (2)
250A PANEL,
100A MAIN BREAKER
208-120 VOLTS
POWER (3) 250A PANEL
208-120 VOLTS
WATER AVAILABLE
GAS N/A
SANITARY AVAILABLE
CFM SEE RFP
GENERAL NOTES:
1. ALL INFORMATION IS FOR
REFERENCE ONLY. ALL CONDITIONS
MUST BE FIELD VERIFIED BY TENANT
PRIOR TO ISSUANCE OF
CONSTRUCTION DRAWINGS.
2. ALL FINISHES FOR ASSIGNED
SPACE TO BE PROVIDED BY TENANT.
N/A= NOT AVAILABLE
TBD= TO BE DETERMINED
Concession Locations McNamara Terminal
ATTACHMENT 'F'
Moving Walkway
TELECOM/DATA AVAILABLE
POWER (2)
POWER (1)
POWER (3)
CFM SEE RFP
Package 2
Attachment F - LODs
DTW Phase 4 F&B - RFP #240757