This document is an Attachment 'F' from Detroit Metropolitan Wayne County Airport (DTW) for Request for Proposal (RFP) #240757, specifically detailing concession locations within the McNamara Terminal. The attachment provides detailed floor plans and utility information for three separate commercial spaces: Space 3-1A/3-1B (2,680 S.F.), Space 8-2A (762 S.F.), and Space L-15 (3,620 S.F.), all located in Concourse A. These spaces are part of a Phase 4 Food & Beverage (F&B) opportunity, with each location including specific details about available utilities such as electricity, water, sanitary systems, and telecommunications.

The spaces are configured with various existing infrastructure elements like water heaters, sinks, drains, and electrical panels. Each location has unique electrical configurations, with power sources ranging from 100-125 AMP panels and varying voltage specifications. The documents emphasize that all information is for reference only, and potential tenants must field verify all conditions prior to construction. The spaces are positioned near gate holdrooms and the concourse, with proximity to moving walkways and other terminal infrastructure. The RFP indicates these are tenant improvement opportunities with spaces to be developed according to the winning bidder's specific requirements.

View the file

Other files

File Type Posted
Attachment B - Phase 4 F_B Concepts _ DTW Concessions Maps 9.25.pdf PDF
Attachment K-2 - ACDBE Vendor Information Forms.pdf PDF
Attachment C - McNamara Passenger Flow Zones Final.pdf PDF
Attachment K-4 - ACDBE Commitment Form - Package 2.pdf PDF
Attachment H I J - Pkg 1.xlsx XLSX spreadsheet
Attachment K-4 - ACDBE Commitment Form - Package 1.pdf PDF
Attachment L-3 Sample Excel Prevailing Wage for all RFB.xlsx XLSX spreadsheet
Attachment N - Bar Loung Summary of Specs.pdf PDF
Attachment L-2 - Prevailing Wage Instructions 2024.docx DOCX document
Attachment L-4 No Work Confirmation Form.pdf PDF
Attachment K-3 - ACDBE Vendor Summary Form.pdf PDF
Attachment E - DTW Enplanements 2019 - Present.xlsx XLSX spreadsheet
Attachment O - DTW Concessions Manual.pdf PDF
Attachment A - Airport Diagram.pdf PDF
Attachment L-5 wh347.pdf PDF
Attachment L-1 General Decision for RFP Solicitation Number 240757.pdf PDF
Attachment K-6 - Sample ACDBE Monthly Participation Report.pdf PDF
Attachment Q1 - Form of Agreement Pkg 1.docx DOCX document
Attachment H I J - Pkg 2.xlsx XLSX spreadsheet
Attachment M - DTW McNamara Historical Fees F_B 2019 - 2024.xlsx XLSX spreadsheet
Attachment G - Current Photos of Spaces.pdf PDF
Attachment P - Temporary Gate Pass Form for site tour.pdf PDF
Attachment D - DTW McNamara F_B Sales 2019 - Present.xlsx XLSX spreadsheet
Attachment K-5 - ACDBE FAA Joint-Venture-Guidance.pdf PDF
Attachment K-1 - ACDBE Program Overview.docx DOCX document
Attachment Q2 - Form of Agreement Pkg 2.docx DOCX document
RFP #240757- Food Beverage Phase 4.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T

EP-A

EP-B

NOT TO SCALE

Area of work

Space 3-1A / 3-1B - Concourse A 2,680 S.F.

Concourse

Space 3-1A Gate A20 Holdroom

Exterior windows

McNamara Terminal - Key Plan

AVAILABLE UTILITIES (B)

ELECTRICITY

PANEL EP-B:

400 AMP DOWNSIZED

TO 300 AMP / 84

BREAKER SPACES

3-PHASE

VOLTAGE

120/ 208V

(112.5 KVA

TRANSFORMER /

200A / 480V)

WATER AVAILABLE BELOW

GAS N/A

SANITARY AVAILABLE BELOW

CFM BUILDING AIR

TELECOM/DATA AVAILABLE

GENERAL NOTES:

1. ALL INFORMATION SHOWN IS FOR REFERENCE

ONLY. ALL CONDITIONS MUST BE FIELD

VERIFIED BY TENANT PRIOR TO

COMMENCEMENT AND ISSUANCE OF

CONSTRUCTION DRAWINGS.

2. ALL CONSTRUCTION AND FINISHES FOR ANY

ASSIGNED SPACE TO BE PROVIDED BY TENANT.

KEY:

TBD = TO BE DETERMINED / LOCATED BY TENANT

N/A = NOT AVAILABLE FOR THIS SPACE

Concession Locations McNamara Terminal

ATTACHMENT 'F'

Space 3-1B

N

AVAILABLE UTILITIES (A)

ELECTRICITY

PANEL EP-A:

100 AMP / 42

BREAKER SPACES

3-PHASE

VOLTAGE 120/208V

WATER AVAILABLE BELOW

GAS N/A

SANITARY AVAILABLE BELOW

CFM BUILDING AIR

TELECOM/DATA AVAILABLE

EXISTING

WATER HEATER

PRIOR ELEC.

WASHER/DRYER

EXISTING SINK

WITH DRAIN

EXISTING COMMON

DRAINS / FOOTSINK

(WATER)

EXISTING

WATER METER

EXISTING

WATER METER

EXISTING SINK &

FLOOR DRAINS

DIMENSIONS SHOWN ARE FOR

GENERAL PURPOSES ONLY.

DIMENSIONS MUST BE

CONFIRMED BY ENTITY

ENGAGING IN OPPORTUNITY

PLANNING AND DEVELOPMENT.

Package 1

Attachment F - LODs DTW Phase 4 F&B - RFP #240757

AutoCAD SHX Text

TERMINAL BUILDING

AutoCAD SHX Text

CONCOURSE A

AutoCAD SHX Text

WEST CONCOURSE

AutoCAD SHX Text

CONCOURSE B

AutoCAD SHX Text

CONCOURSE C

AutoCAD SHX Text

EAST CONCOURSE

EP

EP

TRAN.

NOT TO SCALE

Area of work

Space 8-2A - Concourse A 762 S.F.

Gate A61 Holdroom

Concourse

McNamara Terminal - Key Plan

Concession Locations McNamara Terminal

ATTACHMENT 'F'

Space 8-2A

N

AVAILABLE UTILITIES

ELECTRICITY

400 AMP DOWNSIZED

TO 300 AMP / 84

BREAKER SPACES

3-PHASE

VOLTAGE

120/208V

(112.5 KVA

TRANSFORMER 480V

/ 200 AMP)

WATER AVAILABLE ABOVE

GAS N/A

SANITARY AVAILABLE BELOW

CFM BUILDING AIR

TELECOM/DATA AVAILABLE

GENERAL NOTES:

1. ALL INFORMATION SHOWN IS FOR REFERENCE

ONLY. ALL CONDITIONS MUST BE FIELD

VERIFIED BY TENANT PRIOR TO

COMMENCEMENT AND ISSUANCE OF

CONSTRUCTION DRAWINGS.

2. ALL CONSTRUCTION AND FINISHES FOR ANY

ASSIGNED SPACE TO BE PROVIDED BY TENANT.

KEY:

TBD = TO BE DETERMINED / LOCATED BY TENANT

N/A = NOT AVAILABLE FOR THIS SPACE

EXISTING

WATER HEATER

EXISTING WATER

& DRAIN

EXISTING

JAN. SINK

DIMENSIONS SHOWN ARE FOR

GENERAL PURPOSES ONLY.

DIMENSIONS MUST BE

CONFIRMED BY ENTITY

ENGAGING IN OPPORTUNITY

PLANNING AND DEVELOPMENT.

Package 1

Attachment F - LODs DTW Phase 4 F&B - RFP #240757

AutoCAD SHX Text

TERMINAL BUILDING

AutoCAD SHX Text

CONCOURSE A

AutoCAD SHX Text

WEST CONCOURSE

AutoCAD SHX Text

CONCOURSE B

AutoCAD SHX Text

CONCOURSE C

AutoCAD SHX Text

EAST CONCOURSE

A3-479

A3-483BA3-483A A3-483C

A3-479FREE

Area of work

Space L-15 - Concourse A

3,620 S.F. NNOT TO SCALE

Concourse

Gate A43 Holdroom Space L-16

McNamara Terminal - Keyed Plan

AVAILABLE UTILITIES

ELECTRICITY (3 SOURCES)

POWER (1)

125A PANEL,

100A MAIN BREAKER

208-120 VOLTS

POWER (2)

250A PANEL,

100A MAIN BREAKER

208-120 VOLTS

POWER (3) 250A PANEL

208-120 VOLTS

WATER AVAILABLE

GAS N/A

SANITARY AVAILABLE

CFM SEE RFP

GENERAL NOTES:

1. ALL INFORMATION IS FOR

REFERENCE ONLY. ALL CONDITIONS

MUST BE FIELD VERIFIED BY TENANT

PRIOR TO ISSUANCE OF

CONSTRUCTION DRAWINGS.

2. ALL FINISHES FOR ASSIGNED

SPACE TO BE PROVIDED BY TENANT.

N/A= NOT AVAILABLE

TBD= TO BE DETERMINED

Concession Locations McNamara Terminal

ATTACHMENT 'F'

Moving Walkway

TELECOM/DATA AVAILABLE

POWER (2)

POWER (1)

POWER (3)

CFM SEE RFP

Package 2

Attachment F - LODs

DTW Phase 4 F&B - RFP #240757

File details come from the government source that posted it. Updated .