Attachment E - DLA Energy Quality Provisions C . E QAPS.pdf
PDF 19 MB Posted
- Solicitation number
- SPE60525R0213
- Issued by
-
Defense Logistics Agency Energy
About this file
The provided document is an Adobe PDF portfolio splash screen instructing users to open the file in Acrobat X or Adobe Reader X or later versions. The image displays the Adobe PDF logo on a stylized document with red and white coloring, along with a button to "Get Adobe Reader Now!" This appears to be a standard initial page for a PDF portfolio and does not contain substantive contract-related information.
The actual contract file details are provided in the accompanying metadata, which describes a Defense Logistics Agency (DLA) Energy solicitation (SPE60525R0213) for Direct Delivery Fuels. This is a total small business set-aside for fuel product supply covering Idaho, Montana, Oregon, and Washington from October 2025 through September 2030. The solicitation requires proposals by 2 June 2025 at 4:30pm EST, submitted via the Offer Entry Tool. Contracts will be awarded on an All-or-None basis per cluster, meaning bidders must propose on all items within a selected cluster. The NAICS code is 324110, and the government intends to award without discussions, emphasizing the need for complete and competitive initial proposals.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SF 30_SPE60525R0213_Amd 0004_.pdf | ||
| SF 30_SPE60525R0213_Amd 0003.docx | DOCX document | |
| SF 30_SPE60525R0213_Amd 0003.docx | DOCX document | |
| SF 30_SPE60525R0213_Amd 0002 Final.pdf | ||
| SPE60525R0213_V.1.pdf | ||
| SF 30_SPE60525R0213_Amd 0001.pdf | ||
| COG 8 Line Items_V.1.xlsx | XLSX spreadsheet | |
| Attachment D - PCS OET Vendor Guide.pdf | ||
| Attachment G - Safety Data Sheet.pdf | ||
| Attachment B - AMPS Role Guide.pdf | ||
| Attachment C - Requesting the OET Vendor Role in AMPS Guide.pdf | ||
| SPE60525R0213 Final.pdf | ||
| Attachment F - Additional Text Instructions.pdf | ||
| Attachment A - Schedule.pdf | ||
| COG 8 Line Items.xlsx | XLSX spreadsheet | |
| Attachment H - COG 8 Line Items.pdf |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For the best experience, open this PDF portfolio in
Acrobat X or Adobe Reader X, or later.
Get Adobe Reader Now!
http://www.adobe.com/go/reader
PAGE 1 OF 3DLA FORM 1889, JUL 2023
Prescribed by: eSOP 4155.05-001 Sponsor: J3
SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)
PREVIOUS EDITION IS OBSOLETE Add Continuation Page
Print Form Email Form Clear
REV DESCRIPTION DATE APPROVED
ENERGY QAP C1.02 03/11/2025
REVISIONS
C1.02 GENERALIZED TECHNICAL GUIDANCE (MAR 2025)
(a) Geographic Requirements
a. Supplies delivered under this contract shall conform to all federal, state, and local environmental requirements applicable to the geographic location of the receiving activity on the date of delivery. This includes delivery of fuel and documentation in a manner consistent with existing or future Title V (Clean Air Act) Permits. In the event that a federal, state, or local environmental requirement is more stringent than a similar requirement in a fuel specification contained in this contract, the Contractor shall deliver product that complies with the more stringent requirement. Product that fails to meet the more stringent environmental requirement will be considered nonconforming supply.
b. All supplies furnished under this contract shall fully meet the requirements of the applicable specification(s) as cited in the C QAPs included in this contract.
(b) Certificates of Analysis
a. The term “certificate of analysis” may also be referred to as “certificate of quality”, “quality report”, “COA”, “COQ”, “test report” or any laboratory report used to confirm QAP, specification or test method conformance.
b. Certificate(s) of analysis (COAs) submitted under this solicitation, shall not be older than 90 days from the issue date of this solicitation.
i. COAs older than 90 days may be requested for informational purposes.
c. COA(s) shall contain, at a minimum, the following information:
i. Sample test date
ii. Test result(s)
iii. Test method(s) for each test
iv. Signature or stamp by a laboratory or QC manager
DISTRIBUTION
STATEMENT - A
APPROVED FOR
PUBLIC RELEASE
DISTRIBUTION IS
"UNLIMITED"
DATE
03/13/2025
APPROVED BY
03/11/2025
REVIEWED BY
03/11/2025
PREPARED BY
DRAWING NUMBERSCALE
1:1
CODE ID NO.
52838
SIZE
A
NSN
ITEM
ENERGY QAP C1.02
DLA Land & Maritime DLA Troop Support DLA Aviation clear
DEFENSE LOGISTICS AGENCY, ENERGY
8725 JOHN J. KINGMAN RD
FORT BELVOIR, VIRGINIA 22060-6222
DLA Energy
PAGE 2 OF 3DLA FORM 1889, JUL 2023
d. Direct Delivery Fuels Purchase program only
i. Domestic locations and US territories: “Typicals” or ”specification sheets” are acceptable for the products listed below --
1. Aviation Fuel
2. Gasoline (including E85)
3. Diesel (including BDI/B20)
4. Heating oil
ii. Overseas locations: COAs are required for all overseas locations for all products.
iii. Marine Gasoil (MGO): A COA is required for all domestic and overseas MGO solicitations.
(c) ASSIST
a. Unless otherwise specified, current versions of defense or federal specifications, standards, military handbooks, commercial item descriptions, qualified product lists, and other related technical documents cited in this solicitation/contract can be accessed from the Department of Defense (DoD) Acquisition Streamlining and Standardization Information System (ASSIST) database at https://assist.dla.mil under or via ASSIST Quick Search at http://quicksearch.dla.mil. ASSIST is the official source for all Defense Standardization Program documents and contains the most current information on documents prepared by the DoD, as well as information on how to acquire referenced non-Government standards that have been adopted for DoD use.
i. Note that commercial or foreign specifications are not located on ASSIST and must be obtained from the relevant sponsoring organization (e.g. ASTM, SAE, API, ISO, etc.).
ii. Registered ASSIST account holders may establish profiles to receive automatic E-mail alerts when changes are planned or made to documents of interest by selecting criteria on the [Alert Portal Profile Maintenance] screens accessed from the [User Profile] menu. Users may also view or download a bi-monthly summary of changes to the ASSIST database under the [ASSIST Update] menu.
DISTRIBUTION STATEMENT - A
APPROVED FOR PUBLIC RELEASE
DISTRIBUTION IS "UNLIMITED"
SUPPLEMENTAL QUALITY ASSURANCE PROVISION
(SQAP)
PAGE 3 OF 3DLA FORM 1889, JUL 2023
b. ASSIST Quick Search Instructions
i. Go to http://quicksearch.dla.mil
ii. Type in the numeric portion of the specification or Qualified Product List (QPL) into the “Document ID:” fillable area and click on the Search button.
iii. Look through the search results to find the desired document and click on the “Document ID”.
1. For specifications: click on the .pdf link under “Media”.
2. For QPL information: click on the “QPL-XXXXX” link located under the Document ID section.
a. On the next screen; within the “Revision History”, click on the “View QPD Data” which will take you to the Qualified Product Database.
b. Once you are in the Qualified Product Database, Click on the link in the “Govt Designation” Column to view qualified products.
c. To view qualified source plants, click on the Source Plants link under the Related Links column.
PAGE OF
DLA FORM 1889, JUL 2023
D L A FORM 0 0 1 3, AUGUST 20 22
Prescribed by: eSOP 4155.05-001 Sponsor: J3
SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)
DLA NOT FOR PRODUCTION
PREVIOUS EDITION IS OBSOLETE
REV
DESCRIPTION
DATE
APPROVED
REVISIONS
SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)
DISTRIBUTION STATEMENT - A
APPROVED FOR PUBLIC RELEASE
DISTRIBUTION IS "UNLIMITED"
REV
DESCRIPTION
DATE
APPROVED
REVISIONS
DISTRIBUTION STATEMENT - A
APPROVED FOR PUBLIC RELEASE
DISTRIBUTION IS "UNLIMITED"
SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)
9.0.0.2.20100902.2.720808
Form ID - Form Title
Form ID - Form Title
Randy Davis
DLA DT
DLA DT
Current Page Number:
Total Number of Pages:
Click this button to Print this form.:
Click this button to Email form.:
btnClear:
Button1:
rev:
description: ENERGY QAP C1.02 revdate: 2025-03-11 revapproved:
revcomments:
apprdate: 2025-03-13 apprBy:
reviewdate: 2025-03-11 revBy:
prepdateA: 2025-03-11 prepbyA:
drawingNum:
scale: 1:1 codeIDNo: 52838 size: A nsn:
itemdesc: ENERGY QAP C1.02 btnDSCC:
btnDSCP:
btnDSCR:
line1: DEFENSE LOGISTICS AGENCY, ENERGY line2: 8725 JOHN J. KINGMAN RD line3: FORT BELVOIR, VIRGINIA 22060-6222 revcomments2:
totInstances: 2.00000000
DLA ENERGY QAP E22 9 Feb 2022 9 Feb 2022
ENERGY QAP E22 LIST OF INSPECTION OFFICES FOR DLA ENERGY CONTRACTS (DLA ENERGY) (FEB 2022)
The following lists shall be used to identify the Government inspection office assigned inspection and/or acceptance responsibility for DLA Energy contracts in a particular geographic area. These contracts include, but are not limited to, those for bulk petroleum products and additives, into-plane refueling, petroleum storage and laboratory services, coal, aerospace energy (including compressed gases), and posts, camps, and stations. The area of inspection responsibility and corresponding office code are assigned in paragraphs (a) and (b). The address and phone number of each inspection office, by office code, is provided in paragraph (c). Unless a particular inspection office is identified in another part of the contract, the assignments in this QAP shall apply.
(a) AREAS OF RESPONSIBILITY AND OFFICE CODES WITHIN THE CONTINENTAL UNITED STATES
(CONUS):
Alabama 110 Maine 110 Oklahoma 110 Arizona 120 Maryland 110 Oregon 120 Arkansas 110 Massachusetts 110 Pennsylvania 110 California 120 Michigan 110 Rhode Island 110 Colorado 120 Minnesota 110 South Carolina 110 Connecticut 110 Mississippi 110 South Dakota 110 Delaware 110 Missouri 110 Tennessee 110 District of Columbia 110 Montana 120 Texas 110 I Florida 110 Nebraska 110 Utah 120 Georgia 110 Nevada 120 Vermont 110 Idaho 120 New Hampshire 110 Virginia 110 Illinois 110 New Jersey 110 Washington 120 Indiana 110 New Mexico 120 West Virginia 110 Iowa 110 New York 110 Wisconsin 110 Kansas 110 North Carolina 110 Wyoming 120 2
Kentucky 110 North Dakota 110 Louisiana 110 Ohio 110
EXCEPTIONS:
1 The El Paso, Texas, area is assigned to Code 120 (DLA Energy Americas West).
2 The Newcastle, Wyoming, area is assigned to Code 110 (DLA Energy Americas East).
DEFENSE LOGISTICS AGENCY ENERGY
8725 JOHN J. KINGMAN ROAD
DISTRIBUTION PREPARED BY DATE ITEM
STATEMENT -A DLA ENERGY QAP E22
APPROVED FOR REVIEWED BY DATE NSN CODE IDNO.
PUBLIC RELEASE MULTIPLE 52838
DISTRIBUTION IS APPROVED BY DATE SIZE SCALE DRAWING NUMBER
DLA FORM 1889, OCT 2011 PREVIOUS EDITION IS USABLE Add Continuation Page SHEET 1 OF 4 PDF(DLA)
(b) AREAS OF RESPONSIBILITY AND OFFICE CODES OUTSIDE THE CONTINENTAL UNITED STATES (OCONUS) (INCLUDING ALASKA AND HAWAIi):
Afghanistan 400 Cyprus 200 Malaysia 300 Singapore 300 Africa 200 3 Egypt 400 3 Maldives 300 South America 110 Alaska 130 Europe (Continental) 200 Malta 200 South Korea 300 Antarctica 300 Georgia 200 Mauritius 200 Sri Lanka 300 Armenia 200 Greenland 200 Mexico 110 Syria 400 Ascension Island 110 Hawaiian Islands 300 Midway Island 300 Taiwan 300 Australia 300 Hong Kong 300 Mongolia 300 Tajikistan 400 Azerbaijan 200 Iceland 200 Myanmar 300 Thailand 300 Azores 200 India 300 Nepal 300 Turkey 200 Bahrain 400 Indonesia 300 New Zealand 300 Turkmenistan 400 Bangladesh 300 Ireland 200 North Korea 300 United Arab Bermuda 110 Iran 400 Oman 400 Emirates 400 Bhutan 300 Iraq 400 Pacific Islands United Kingdom 200 Brunei 300 Israel 200 (Central & South) 300 Uzbekistan 400 Cambodia 300 Japan 300 Pakistan 400 Vietnam 300 Canada 1104 Jordan 400 Papua New Guinea 300 Wake Island 300 Canary Island 200 Kazakhstan 400 Philippines 300 Yemen 400 Caribbean Islands 110 Kuwait 400 Qatar 400 Central America 110 Kyrgyzstan 400 Russia 200 Chagos Archipelago 300 Laos 300 Ryukus Islands, Japan 300 China 300 Lebanon 400 Saudi Arabia 400 Comoros 200 Madagascar 200 Seychelles Is. 200
EXCEPTIONS:
3 Except for Egypt, which is assigned to DLA Energy Middle East (Code 400), all other countries in Africa fall under DLA Energy Europe (Code 200).
4 For Canada locations, contact DLA Energy Americas East (Code 110) to confirm coverage.
(c) INSPECTION OFFICES AND CODES.
110. DLA Energy Americas East ATTN: Quality Manager 5
Federal Building, Suite 1005 2320 LaBranch Street Houston, TX 77004-1091 Phone: (713) 332-4113
FAX: (713) 718-3891
(SOAP)
DISTRIBUTION STATEMENT -A
SIZE SCALE CODE IDNO.
DRAWING NUMBER
DLA FORM 1889, OCT 2011 PREVIOUS EDITION IS USABLE Add Continuation Page SHEET 2 OF 4 PDF(DLA)
120. DLA Energy Americas West
S , CA 90
Phone: (424) 347-3101/3102
FAX: (424) 347-3120
130. DLA Energy Americas North
1480 Sijan Street, Suite 300 Joint Base Elmendorf-Richardson, AK 99505 Phone: (907) 384-7180
FAX: (907) 384-1086
200. DLA Energy Europe and Africa
Military Mailing Address:
DLA Energy Petroleum Lab
CMR422
APO AE 09067-0422
Phone: 49-63 l-3406-2285/2286 6
FAX: 49-631-3406-2289 6
Commercial Shipping Address:
DLA Energy Petroleum Lab ATTN: Quality Manager Bldg. 320, Rhine Ordinance Barracks Am Opelkreisel 67663 Kaiserslautern, Germany
300. DLA Energy lndo-Pacific
Bldg. 17000, Room 21
APO AP 96543
Phone: (671) 366-7762
FAX: (671) 366-7767
[Location: Guam]
DLA FORM 1889, OCT 2011 PREVIOUS EDITION IS USABLE Add Continuation Page SHEET 3 OF 4 PDF(DLA)
400. DLA Energy Middle East
PSC 851, Box 180
FPO AP 09834-2800
Phone: 973-1785-6493 6
FAX: 973-1785-4650 6
[Location: Bahrain]
5 Designated location of the DLA Energy Regional Quality Manager/Pre-Award Survey Monitor.
6 Dial 011 before these numbers when calling from the U.S. When calling these numbers from outside the U.S., use the appropriate international long distance prefix for the country where the call originates.
DLA FORM 1889, OCT 2011 PREVIOUS EDITION IS USABLE Add Continuation Page SHEET 40F 4 PDF(DLA)
2022-02-09T15:07:40-0500
MILLS.KEITH.1050183110
2022-02-09T15:07:59-0500
MILLS.KEITH.1050183110
2022-02-14T08:44:39-0500
KNAPP.RICHARD.BRUCE.1027134021
Date1_af_date: 2/9/22
Date2_af_date: 2/9/22
Date3_af_date: 2/14/22
DEFENSE LOGISTICS AGENCY ENERGY Page 1 of 1
C16.23-2 COMMERCIAL MARINE GAS OIL MINIMUM REQUIREMENTS (DLA ENERGY SEPT 2024)
Product Classification
NATIONAL STOCK NUMBER PRODUCT NOMENCLATURE DLA ENERGY PRODUCT CODE UNIT OF ISSUE
9140-01-313-7776 Marine Gas Oil MGO Gallons 9140-01-417-6843 Marine Gas Oil MGT Metric Tons
Supplies delivered under this contract, the Contractor shall conform to all Federal, State, and local environmental requirements applicable to the geographic location of the receiving activity on the date of delivery. The Contractor shall also comply with all applicable International Agreements, Treaties, Conventions, and the like to which the United States is a party or with whose terms the receiving activity has otherwise agreed to comply, including but not limited to, the requirements of MARPOL 73/78 Annex VI Regulations 14 & 18. The Contractor shall be responsible for determining the existence of all such requirements prior to the time deliveries are made. This includes delivery of fuel and documentation in a manner consistent with any existing or after-imposed Title V (Clean Air Act) Permits.
The list of such requirements contained in this contract is not intended to be a complete list, and the Contractor shall be responsible for determining the existence of all such requirements. Selected regional environmental requirements are highlighted in the SPECIFICATIONS (CONT’D) clause. In the event that an International, Federal, State, and /or local environmental requirement, as identified above, is more stringent than a requirement contained in this contract, the Contractor shall deliver product(s) that complies with the more stringent requirement. Product(s) that fails to meet the more stringent requirement will be considered nonconforming supply. Product(s) to be supplied shall fully meet the requirements of the applicable specification(s). In the event that compliance with the more stringent requirement causes the contractor to incur additional costs, the contractor may request an equitable adjustment.
Product shall conform to the requirements of the latest revision of ISO 8217, Category ISO-F-DMA. In Accordance with Annex A of ISO 8217, the de minimis value of FAME shall be 0.5 volume %. Offeror/Supplier shall ensure product offered meets ISO 8217 de minimis FAME requirement. The following are additional requirements or approved modifications to specifications.
(a) SPECIFICATION MODIFICATIONS
(1) TESTING
(i) Hydrogen sulfide testing is not required
(ii) In addition to ISO 8217 approved sulfur tests, the following test methods are approved for Sulfur testing: ASTM D5453, D1266, D1552, D2622, D3120, D7039, or ISO16591. See section 6.3 of ISO 8217 for referee test method. For a total sulfur content of less than 0.05 mass % (500 ppm), the latest revision of ASTM D5453 is the recommended ASTM method.
(iii) The following test methods are approved for FAME testing per ISO 8217: IP 579 or ASTM D 7963. Test method EN 14078 is an equivalent test method for IP 579 and approved for FAME testing. See section 6.9 ISO 8217 for referee test method.
(iv) ASTM International Test Methods equivalent to ISO test methods referenced in ISO 8217, DMA testing, are approved for use.
(2) Environmental
(i) As of 01 JAN 2020, under the requirements listed in MARPOL 73/78 Annex VI Regulation 14, MGO-DMA (MGO & MGT) purchased under DLA Energy programs shall not exceed a revised maximum sulfur weight percent of 0.5 (% m/m). This requirement does not supersede more stringent federal, state, and local environmental requirements.
(ii) Per MARPOL 73/78 Annex VI Regulation 14, for ships operating in the most current emission control areas, the sulfur content of marine gas oil shall not exceed 0.10% mass (1000 ppm).
(iii) Per 40 CFR Section 80.510, the Marine Gas Oil sulfur requirement for all refineries and deliveries to ports within Continuous United States (CONUS) shall not exceed 0.0015 mass % (15 ppm) sulfur.
(b) ADDITIVES: Marine Gas Oil shall contain no black dye.
(c) OTHER REQUIREMENTS: Unless otherwise indicated by the Contractor in writing, prior to award, and in accordance with the
EVALUATION (SHIP’S BUNKERS) provision, the product offered shall fully meet the applicable specification. The supplier shall provide to the receiving vessel a “Statutory Sample” of at least 500 mL in volume, taken from the receiving vessel’s inlet bunker manifold, together with a Bunker Delivery Note (BDN). This sample will be sealed and carry a sample tag that provides the documentation required per MARPOL 73/78 Annex VI Regulation 18.
Signature
Prepared by:
Quality / Technical Support Office Approval:
Contracting Approval:
DISTRIBUTION STATEMENT – A: APPROVED FOR PUBLIC RELEASE. DISTRIBUTION IS UNLIMITED
C16.23-2 COMMERCIAL MARINE GAS OIL MINIMUM REQUIREMENTS (DLA ENERGY SEPTAPR 20241)
(a) SPECIFICATION MODIFICATIONS
SignaturePrepared by:
SignatureQuality Technical Support Office Approval:
SignatureContracting Approval:
2024-09-13T13:19:25-0400
MACLANE.SKYLLAR.BRYANNA.1252141827
2024-09-17T12:27:09-0600
BANISZEWSKI.DANIEL.J.1287388698
2024-09-23T08:24:46-0400
ROSE.JAMAAL.R.1050293366
PDF (DLA)DLA FORM 1889, OCT 2011
SHEET 1 OF 2PREVIOUS EDITION IS USABLE Add Continuation Page
Print Form Email Form Clear Export Data Import Data About Check for Newer Version Contact Us
ENERGY QAP E35 December 2011
E35 NONCONFORMING SUPPLIES AND SERVICES
(a) DEFINITION: As used in this contract provision:
Deviation is defined as a written authorization granted after contract award and prior to manufacture of an item, to depart from a particular performance or design requirement of a contract, specification, or referenced document, for a specific number of units or specific period of time, normally the duration of the contract.
Extraordinary situation means the matter cannot await resolution until the next DLA Energy business day (0800 to 1630 hours EST, Monday through Friday, Federal Holidays excluded).
Waiver is defined as a written authorization granted after contract award to accept a configuration item or other designated item which, during production or after having been submitted for inspection, is found to depart from specified requirements, but nevertheless is considered suitable for use “as is” or after repair by an approved method. Approval is on a case-by-case basis and is normally for a set period of time.
(b) The Government may, at its discretion, accept nonconforming supplies or services. In such cases, the Contractor must obtain a deviation or waiver from the Contracting Officer prior to acceptance.
(c) The following procedures shall be used to request a deviation or waiver.
(1) Requests for deviations and waivers shall be submitted by the Contractor to the Contracting Officer with a copy to the appropriate Inspection Office referenced in the LIST OF INSPECTION OFFICES FOR DLA ENERGY CONTRACTS or QUALITY REPRESENTATIVE contract provision of this contract. Each request shall provide the following information: Contractor name; name and contact information of the contractor's authorized negotiator; contract number; contract line item number and product nomenclature, clause or contract provision number, paragraph and subparagraph, as appropriate; the nature of the request; the reason for the request; the corrective action being taken by the Contractor to correct and prevent recurrence of the condition(s) causing the nonconformance; and an agreement to pay an equitable price reduction, estimated and proposed by DLA Energy, over and above the administrative fee, contingent on the impact of the specific circumstances on DLA Energy relative to approval of the deviation or waiver.
(2) In extraordinary situations, the Contractor may initially submit a verbal request for a waiver, but not a deviation, to the Contracting Officer.
Written requests shall be submitted to the Contracting Officer by the next DLA Energy business day (0800 to 1630 hours EST, Monday through Friday, Federal Holidays excluded). If the Contracting Officer cannot be reached, the Duty Officer shall be contacted to provide the necessary information to the proper individuals as soon as possible. The Duty Officer's telephone number is (800) 286-7633 or (703) 767-8420.
(3) If a deviation or waiver is granted, the contract will be modified to accept the nonconforming supplies or services and to require the Contractor to provide an equitable price reduction or other adequate consideration commensurate with the deviation or waiver being granted. If the situation warrants, a deviation or waiver may be granted without prior agreement on price reduction or other consideration, subject to agreement by the Contractor, or its representative, to subsequent negotiation. Such an agreement, in addition to a brief description of the terms of the deviation or waiver, shall be documented on the shipping document or other appropriate correspondence. After negotiations, failure to agree on adequate consideration shall be a dispute concerning a question of fact within the meaning of the Disputes paragraph of the CONTRACT TERMS AND CONDITIONS - COMMERCIAL ITEMS contract provision of this contract.
(4) If a deviation or waiver is granted and the nonconforming supplies are accepted, then in no event will consideration be less than $500, which covers administrative costs, plus any additional cost of Government reinspection or retest, if necessary.
5) If a deviation or waiver is granted modifying this contract, but the supplies accepted are subsequently determined to be in conformity with contract specifications, the Contractor shall still be obligated to pay the consideration originally agreed upon in support of the deviation or waiver.
If, however, this consideration exceeds $1000, a second contract modification shall be issued reducing the Contractor's obligation to $1000 (the administrative cost of issuing the two required modifications), plus, if appropriate, any cost of Government reinspection or retest performed as a result of the deviation or waiver being granted.
04/18/2014
DATEREVIEWED BY
04/14/2014
MULTIPLE
ENERGY QAP E35
SHEET 2 OF 2PREVIOUS EDITION IS USABLE Add Continuation Page
ENERGY QAP E35 December 2011
(d) When notification of nonconforming supplies is received after the supplies have been accepted, and the Government determines not to exercise its right to reject or to require correction under the INSPECTION OF SUPPLIES - FIXED-PRICE, INSPECTION OF SERVICES - FIXED PRICE, or CONTRACT TERMS AND CONDITIONS - COMMERCIAL ITEMS contract provision, then in no event will consideration be less than $500 to cover administrative costs. This $500 fee is in addition to --
(1) Consideration commensurate with the extent of nonconforming supplies; and
(2) Cost of Government reinspection or retest, if necessary.
The administrative fee will apply to each claim letter issued for off-specification product delivered to an activity.
(e) Contractors shall be held responsible for payment of any fines or penalties imposed on a receiving activity by an environmental enforcement agency, resulting from the delivery of nonconforming supplies under a DLA Energy contract.
(f) Repeated tender of nonconforming supplies or services, including those with only minor defects, will be discouraged by appropriate actions, including, but not limited to, rejecting the supplies or services whenever feasible and documenting the Contractor's performance records.
DRAWING NUMBERSCALE CODE ID NO.
PDF (DLA)
DLA FORM 1889, OCT 2011
SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)
SHEET OF
PREVIOUS EDITION IS USABLE
REV
DESCRIPTION
DATE
APPROVED
REVISIONS
REV
DESCRIPTION
DATE
APPROVED
REVISIONS
DISTRIBUTION STATEMENT - A
APPROVED FOR PUBLIC RELEASE
DISTRIBUTION IS "UNLIMITED"
SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)
Supplemental Quality Assurance Provision (SQAP)
DSCC Form 2291, Feb 2004 online none standard
Quality Assurance
DLA
1 +
No
Tech Qual Deskbook n/a
No
Supplemental Quality Assurance Provision (SQAP) interactive
October 2011 (added Energy; updated supply center names)
CurrentPage:
PageCount:
btnPrint:
btnEmail:
btnClear:
btnExport:
btnImport:
btnAbout:
btnChkVersion:
btnContactUs:
Button1:
rev:
description: ENERGY QAP E35 revdate: December 2011 revapproved:
revcomments:
apprdate: 04/18/2014 apprBy:
reviewdate:
revBy:
prepdateA: 2014-04-14 prepbyA:
drawingNum:
scale:
codeIDNo: 52838 size:
nsn: MULTIPLE itemdesc: ENERGY QAP E35 btnDSCC:
btnDSCP:
btnDSCR:
line1: DEFENSE LOGISTICS AGENCY ENERGY line2: 8725 JOHN J. KINGMAN RD line3: FORT BELVOIR, VIRGINIA 22060-6222 revcomments2:
totInstances: 1.00000000
Quality/Technical Support Office Approval
C16.69-1 GASOLINE AUTOMOTIVE, UNLEADED, REGULAR (PC&S) (DLA ENERGY JUN 2017)
NATIONAL STOCK NUMBER PRODUCT NOMENCLATURE DLA ENERGY PRODUCT CODE
9130-00-148-7103 Gasoline, Regular Unleaded MUR
Supplies delivered under this contract shall conform to all Federal, State, and local environmental requirements applicable to the geographic location of the receiving activity on the date of delivery. This includes delivery of fuel and documentation in a manner consistent with existing or future Title V (Clean Air Act) Permits. In the event that a Federal, State, or local environmental requirement is more stringent than a similar requirement in a fuel specification contained in this contract, the Contractor shall deliver product that complies with the more stringent requirement. Product that fails to meet the more stringent environmental requirement will be considered to be a nonconforming supply. All supplies furnished under this contract shall fully meet the requirements of the applicable specification(s) as cited below. In the event that compliance with the more stringent requirement causes the contractor to incur additional costs, the contractor may request an equitable adjustment.
NOTE: Gasoline Reid Vapor Pressure (RVP) specification requirements are seasonal and vary geographically. Therefore, Contractors are expected to know the In-country, State, or Federal RVP requirements of areas being supplied and comply with those requirements.
GASOLINE AUTOMOTIVE, UNLEADED, REGULAR. Gasoline shall conform to each country specification as listed below:
COUNTRY SPECIFICATION NATIONAL STOCK NUMBER
AUSTRALIA FUEL STANDARD (PETROL) 2001
CANADA CAN/CGSB-3.5-2001
JAPAN JIS K 2202
PHILIPINES PNS/DOE QS 008:2012 9130-00-148-7103
MIDDLE EAST EN 228
ALL OTHER REGIONS ASTM D4814
LOCAL SPECIFICATIONS: In-country specifications not meeting the specification requirements in the chart above, but meet local requirements may also be submitted for review and approval.
(a) OCTANE REQUIREMENTS
(1) Unleaded regular automotive gasoline shall meet the Motor Octane Number (MON), Research Octane Number (RON) and/or
Anti-Knock Index (AKI) limits described in the specification listed for each country or the in-country requirements when applicable.
(2) Reductions for altitude and seasonal variations are allowed for all AKI values in accordance with specification listed for each country requirements when applicable.
(b) OXYGENATE REQUIREMENTS.
(1) In order to achieve minimum/maximum oxygen content limits specified per Federal, State, and local environmental requirements, supplies shall only include oxygenates that are permitted by environmental regulations applicable to the time and place of delivery.
(2) Blending of oxygenates into gasoline to meet oxygenated fuel requirements shall be accomplished by mechanical mixing or agitation in a tank, or by in-line blending, prior to loading the product into transport equipment, and the resultant product must meet contract requirements.
2017-06-07T13:33:14-0400
MEREDITH.MICHAEL.E.1290973453
2017-06-07T14:14:28-0400
BANISZEWSKI.DANIEL.J.1287388698
2017-08-24T07:15:59-0400
PETERSON.DAVID.W.1074069483
ENERGY QAP E37 December 2011
E37 SOURCE RESTRICTION AND SOURCE INSPECTION (PC&S)
(a) SOURCE RESTRICTION.
(1) If the Contractor delivers any product that is determined to be off-specification, the Contracting Officer (CO) shall thereafter have the right, upon giving written notice, to require the Contractor to designate a single source of supply for each destination set forth in the contract. Upon receiving such notice, the Contractor shall have 10 days to respond, in writing, after which time the source restriction will become effective.
(2) In addition to the name of a single source of supply, the Contractor must provide the address of the terminal or loading point to be used in drawing the requirements for each item in the contract.
(3) The Contractor may change suppliers only after requesting and receiving the express written approval of the CO.
(b) SOURCE INSPECTION.
(1) If serious quality problems arise or if a quality problem recurs, for which the Contractor was supposed to have taken corrective action, the CO shall, in addition to source restriction, have the right to change the inspection point from destination to origin (source) by advising the Contractor in writing. Source inspection will become effective 10 days after written notice has been received by the Contractor.
(2) At the time the change becomes effective --
(i) All appropriate contract provisions relating to origin inspection shall be incorporated into the contract for the item(s) involved;
(ii) Source restriction, if not already in force, will be invoked for all items involved, in accordance with (a) above; and
(iii) The cognizant DLA Energy field office, upon receiving written notification by the CO, will become the office responsible for inspection at the origin loading or filling point for providing necessary field assistance.
(c) Failure to provide the information requested or to take prompt corrective action may result in the item(s) and/or contract being terminated for default.
04/18/2014
DATEREVIEWED BY
04/14/2014
MULTIPLE
ENERGY QAP E37
SHEET 2 OF 2PREVIOUS EDITION IS USABLE Add Continuation Page
ENERGY QAP E37 December 2011
THIS PAGE WAS INTENTIONALLY LEFT BLANK.
DRAWING NUMBERSCALE CODE ID NO.
SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)
SHEET OF
PREVIOUS EDITION IS USABLE
REV
DESCRIPTION
DATE
APPROVED
REVISIONS
DESCRIPTION
DATE
APPROVED
REVISIONS
DISTRIBUTION STATEMENT - A
APPROVED FOR PUBLIC RELEASE
DISTRIBUTION IS "UNLIMITED"
SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)
Supplemental Quality Assurance Provision (SQAP)
DSCC Form 2291, Feb 2004 online none standard
Quality Assurance
DLA
1 +
No
Tech Qual Deskbook n/a
No
Supplemental Quality Assurance Provision (SQAP) interactive
October 2011 (added Energy; updated supply center names)
CurrentPage:
PageCount:
btnPrint:
btnEmail:
btnClear:
btnExport:
btnImport:
btnAbout:
btnChkVersion:
btnContactUs:
Button1:
rev:
description: ENERGY QAP E37 revdate: December 2011 revapproved:
revcomments:
apprdate: 04/18/2014 apprBy:
reviewdate:
revBy:
prepdateA: 2014-04-14 prepbyA:
drawingNum:
scale:
codeIDNo: 52838 size:
nsn: MULTIPLE itemdesc: ENERGY QAP E37 btnDSCC:
btnDSCP:
btnDSCR:
line1: DEFENSE LOGISTICS AGENCY ENERGY line2: 8725 JOHN J. KINGMAN RD line3: FORT BELVOIR, VIRGINIA 22060-6222 revcomments2:
totInstances: 1.00000000
C16.69-10 DIESEL FUEL SPECIFICATION (PC&S) (DLA ENERGY DEC 2016)
9140-01-524-5174 Grade Number 1-D S15 (ULSD) DS1
Supplies delivered under this contract shall conform to all Federal, State, and local environmental requirements applicable to the geographic location of the receiving activity on the date of delivery. This includes delivery of fuel and documentation in a manner consistent with any existing or after-imposed Title V (Clean Air Act) Permits. The list of such requirements contained in this contract is not intended to be a complete list, and the Contractor shall be responsible for determining the existence of all such requirements. Selected regional environmental requirements are highlighted in the SPECIFICATIONS (CONT’D) clause. In the event that a Federal, State, or local environmental requirement is more stringent than a fuel specification contained in this contract, the Contractor shall deliver product that complies with the more stringent fuel specification. Product that fails to meet the more stringent fuel specification will be considered to be a nonconforming supply. Product(s) to be supplied shall fully meet the requirements of the applicable specification(s) as cited below. In the event that compliance with the more stringent fuel specification causes the contractor to incur additional costs, the contractor may request an equitable adjustment.
Product shall conform to commercial specification ASTM D 975, Grade Number 1-D S15. In accordance with this specification, product shall be visually free of undissolved water, sediment, and suspended matter. Product classification is shown above.
(a) ADDITIVES.
(1) A fuel stabilizer additive conforming to MIL-S-53021, latest revision, may be blended into the fuel to improve the suitability of fuel for long term storage. Permissible additive concentrations are specified in the latest revision of QPL-53021.
(2) A corrosion inhibitor/lubricity improver additive may be blended into the fuel to inhibit corrosion and improve fuel lubricity.
Permissible additive concentration limits are specified in the latest revision of QPL 25017.
(3) A fuel system icing inhibitor may be blended into the fuel to purge small quantities of water from the fuel and prevent the formulation of ice crystals. The additive concentration shall not exceed 0.15 volume percent when tested in accordance with ASTM D 5006.
(b) BLENDING. Blending one grade of diesel fuel with another grade, or other compatible components, to produce a different grade or a variation within a grade is permitted. However, such blending shall be accomplished by mechanical mixing or agitation in a tank, or in-line blending, prior to loading the product into transport equipment, and the resultant product must meet all the requirements of the desired fuel.
(c) LOW TEMPERATURE OPERABILITY / CLOUD POINT REQUIRMENTS. The low temperature performance of diesel fuel shall be defined by the following property. Unless a more restrictive cloud point limit is specified in the contract schedule, the cloud point shall be equal to or lower than the tenth percentile minimum ambient temperature specified in Appendix X5 of ASTM D 975.
Within Alaska for activities where fuel support is limited to April-September, for example "JUN/JUL", "MAY 15 - JUN 15", "DURING SUMMER MONTHS", etc, and fuel will be used year-round in support of continuing operations, the cloud point shall be equal to or lower than the tenth percentile minimum temperature specified in Appendix X5 of ASTM D 975 for the month of January.
MEREDITH.MICHAEL.E.1290973453 Digitally signed by MEREDITH.MICHAEL.E.1290973453 Date: 2016.12.22 15:09:22 -05'00'
BANISZEWSKI.DANIEL.J.1287388698 Digitally signed by BANISZEWSKI.DANIEL.J.1287388698 Date: 2016.12.28 09:10:15 -05'00'
PETERSON.DAVID.W.1074069483 Digitally signed by PETERSON.DAVID.W.1074069483 Date: 2017.01.06 16:49:52 -05'00'
C16.69-11 DIESEL FUEL SPECIFICATION (PC&S) (DLA ENERGY DEC 2016)
9140-01-524-0139 Grade Number 2-D S15 (ULSD) DS2
Supplies delivered under this contract shall conform to all Federal, State, and local environmental requirements applicable to the geographic location of the receiving activity on the date of delivery. This includes delivery of fuel and documentation in a manner consistent with any existing or after-imposed Title V (Clean Air Act) Permits. The list of such requirements contained in this contract is not intended to be a complete list, and the Contractor shall be responsible for determining the existence of all such requirements. Selected regional environmental requirements are highlighted in the SPECIFICATIONS (CONT’D) clause. In the event that a Federal, State, or local environmental requirement is more stringent than a fuel specification contained in this contract, the Contractor shall deliver product that complies with the more stringent fuel specification. Product that fails to meet the more stringent fuel specification will be considered to be a nonconforming supply. Product(s) to be supplied shall fully meet the requirements of the applicable specification(s) as cited above. In the event that compliance with the more stringent fuel specification causes the contractor to incur additional costs, the contractor may
Product shall conform to commercial specification ASTM D 975. In accordance with this specification, product shall be visually free of undissolved water, sediment, and suspended matter. Product classification is shown above. Maximum sulfur content shall be 0.0015 wt%.
(1) A fuel stabilizer additive conforming to MIL-S-53021, latest revision, may be blended into the fuel to improve the suitability of fuel for long term storage. Permissible additive concentrations are specified in the latest revision of QPL-53021.
(2) A corrosion inhibitor/lubricity improver additive may be blended into the fuel to inhibit corrosion and improve fuel lubricity.
(3) A fuel system icing inhibitor may be blended into the fuel to purge small quantities of water from the fuel and prevent the formulation of ice crystals. The additive concentration shall not exceed 0.15 volume percent when tested in accordance with ASTM
(b) BLENDING. Blending one grade of diesel fuel with another grade, or other compatible components, to produce a different grade or a variation within a grade is permitted. However, such blending shall be accomplished by mechanical mixing or agitation in a tank, or in-line blending, prior to loading the product into transport equipment, and the resultant product must meet all the requirements of the
(c) LOW TEMPERATURE OPERABILITY. The low temperature performance of diesel fuel shall be defined by the following property:
CLOUD POINT. Unless a more restrictive cloud point limit is specified in the contract schedule, the cloud point shall be equal to or lower than the tenth percentile minimum ambient temperature specified in Appendix X5 of ASTM D 975. Within Alaska for activities where fuel support is limited to April-September, for example "JUN/JUL", "MAY 15 - JUN 15", "DURING SUMMER MONTHS", etc, and fuel will be used year-round in support of continuing operations, the cloud point shall be equal to or lower than the tenth percentile minimum temperature specified in Appendix X5 of ASTM D 975 for the month of January.
Date: 2016.12.22 15:09:43 -05'00'
Date: 2016.12.28 09:07:05 -05'00'
Date: 2017.01.06 16:51:05 -05'00'
C16.69-12 DIESEL FUEL SPECIFICATION (PC&S) (DLA ENERGY DEC 2016)
9140-01-541-6760 Grade Number 2-D S15 (ULSD) DSS
Supplies delivered under this contract shall conform to all Federal, State, and local environmental requirements applicable to the geographic location of the receiving activity on the date of delivery. This includes delivery of fuel and documentation in a manner consistent with any existing or after-imposed Title V (Clean Air Act) Permits. The list of such requirements contained in this contract is not intended to be a complete list, and the Contractor shall be responsible for determining the existence of all such requirements. Selected regional environmental requirements are highlighted in the SPECIFICATIONS (CONT’D) clause. In the event that a Federal, State, or local environmental requirement is more stringent than a fuel specification contained in this contract, the Contractor shall deliver product that complies with the more stringent fuel specification. Product that fails to meet the more stringent fuel specification will be considered to be a nonconforming supply. Product(s) to be supplied shall fully meet the requirements of the applicable specification(s) as cited below. In the event that compliance with the more stringent fuel specification causes the contractor to incur additional costs, the contractor may
Product shall conform to commercial specification ASTM D 975, Grade Number 2-D S15. In accordance with this specification, product shall be visually free of undissolved water, sediment, and suspended matter. Product classification is shown above
(1) A fuel system icing inhibitor may be blended into the fuel to purge small quantities of water from the fuel and prevent the formulation of ice crystals. The additive concentration shall not exceed 0.15 volume percent when tested in accordance with ASTM D 5006.
(2) A corrosion inhibitor/lubricity improver additive may be blended into the fuel to inhibit corrosion and improve fuel lubricity.
(3) A fuel stabilizer additive conforming to MIL-S-53021, latest revision, may be blended into the fuel to improve the suitability of fuel for long term storage. Permissible additive concentrations are specified in the latest revision of QPL-53021.
(b) BLENDING. Blending one grade of diesel fuel with another grade, or other compatible components, to produce a different grade or a variation within a grade is permitted. However, such blending shall be accomplished by mechanical mixing or agitation in a tank, or in-line blending, prior to loading the product into transport equipment, and the resultant product must meet all the requirements of the
(c) LOW TEMPERATURE OPERABILITY. The low temperature performance of diesel fuel shall be defined by the following
CLOUD POINT. Unless a more restrictive cloud point limit is specified in the contract schedule, the cloud point shall be equal to or lower than the tenth percentile minimum ambient temperature specified in Appendix X5 of ASTM D 975. Within Alaska for activities where fuel support is limited to April-September, for example "JUN/JUL", "MAY 15 - JUN 15", "DURING SUMMER MONTHS", etc, and fuel will be used year-round in support of continuing operations, the cloud point shall be equal to or lower than the tenth percentile minimum temperature specified in Appendix X5 of ASTM D 975 for the month of January.
(d) DYE REQUIREMENT. Product shall have addition of red dye. As a means of identification, the Internal Revenue Service (IRS) requires that a red dye, identified as Solvent Red 164 (alky derivatives of azo benzene azo naphthol), must be added to all nontaxable diesel and all nontaxable kerosene used for purposes other than military jet fuel. The definitions of diesel and kerosene are provided in 26 CFR Section 48.4081-1. The minimum concentration is provided in 40 CFR Part 80.
Date: 2016.12.22 15:10:02 -05'00'
Date: 2016.12.28 09:07:38 -05'00'
Date: 2017.01.06 16:52:23 -05'00'
C16.69-13 DIESEL FUEL SPECIFICATION (PC&S) (DLA ENERGY DEC 2016)
9140-01-541-6767 Grade Number 1-D S15 (ULSD) DSW
Supplies delivered under this contract shall conform to all Federal, State, and local environmental requirements applicable to the geographic location of the receiving activity on the date of delivery. This includes delivery of fuel and documentation in a manner consistent with any existing or after-imposed Title V (Clean Air Act) Permits. The list of such requirements contained in this contract is not intended to be a complete list, and the Contractor shall be responsible for determining the existence of all such requirements. Selected regional environmental requirements are highlighted in the SPECIFICATIONS (CONT’D) clause. In the event that a Federal, State, or local environmental requirement is more stringent than a fuel specification contained in this contract, the Contractor shall deliver product that complies with the more stringent fuel specification. Product that fails to meet the more stringent fuel specification will be considered to be a nonconforming supply. Product(s) to be supplied shall fully meet the requirements of the applicable specification(s) as cited below. In the event that compliance with the more stringent fuel specification causes the contractor to incur additional costs, the contractor may
Product shall conform to commercial specification ASTM D 975, Grade Number 1-D S15. In accordance with this specification, product shall be visually free of undissolved water, sediment, and suspended matter. Product classification is shown above. Maximum sulfur content shall be 0.0015 wt%. Product shall have addition of red dye
(1) A fuel system icing inhibitor may be blended into the fuel to purge small quantities of water from the fuel and prevent the formulation of ice crystals. The additive concentration shall not exceed 0.15 volume percent when tested in accordance with ASTM
(2) A corrosion inhibitor/lubricity improver additive may be blended into the fuel to inhibit corrosion and improve fuel lubricity.
(3) A fuel stabilizer additive conforming to MIL-S-53021, latest revision, may be blended into the fuel to improve the suitability of fuel for long term storage. Permissible additive concentrations are specified in the latest revision of QPL-53021.
(b) BLENDING. Blending one grade of diesel fuel with another grade, or other compatible components, to produce a different grade or a variation within a grade is permitted. However, such blending shall be accomplished by mechanical mixing or agitation in a tank, or in-line blending, prior to loading the product into transport equipment, and the resultant product must meet all the requirements of the
(c) LOW TEMPERATURE OPERABILITY. The low temperature performance of diesel fuel shall be defined by the following
CLOUD POINT. Unless a more restrictive cloud point limit is specified in the contract schedule, the cloud point shall be equal to or lower than the tenth percentile minimum ambient temperature specified in Appendix X5 of ASTM D 975. Within Alaska for activities where fuel support is limited to April-September, for example "JUN/JUL", "MAY 15 - JUN 15", "DURING SUMMER MONTHS", etc, and fuel will be used year-round in support of continuing operations, the cloud point shall be equal to or lower than the tenth percentile minimum temperature specified in Appendix X5 of ASTM D 975 for the month of January.
(d) DYE. As a means of identification, the Internal Revenue Service (IRS) requires that a red dye, identified as Solvent Red 164 (alky derivatives of azo benzene azo naphthol), must be added to all nontaxable diesel and all nontaxable kerosene used for purposes other than military jet fuel. The definitions of diesel and kerosene are provided in 26 CFR Section 48.4081-1. The minimum concentration is provided in 40 CFR Part 80.
Date: 2016.12.22 15:10:43 -05'00'
Date: 2016.12.28 09:07:56 -05'00'
Date: 2017.01.06 16:53:42 -05'00'
Office Approval:
C16.69-17 FUEL OIL, BURNER SPECIFICATION (PC&S) (FL2) (DLA ENERGY DEC 2016)
9140-01-546-1786 Fuel Oil, Burner No. 2 S500 FL2
Supplies delivered under this contract shall conform to all Federal, State, and local environmental requirements applicable to the geographic location of the receiving activity on the date of delivery. This includes delivery of fuel and documentation in a manner consistent with any existing or after-imposed Title V (Clean Air Act) Permits. The list of such requirements contained in this contract is not intended to be a complete list, and the Contractor shall be responsible for determining the existence of all such requirements. Selected regional environmental requirements are highlighted below. In the event that a Federal, State, or local environmental requirement is more stringent than a fuel specification contained in this contract, the Contractor shall deliver product that complies with the more stringent fuel specification. Product that fails to meet the more stringent fuel specification will be considered to be a nonconforming supply. Product(s) to be supplied shall fully meet the requirements of the applicable specification(s) as cited below. In the event that compliance with the more stringent fuel specification causes the contractor to incur additional costs, the contractor may request an equitable adjustment.
Product shall conform to the latest revision of commercial specification ASTM D 396, as modified by the requirement (a).
Product classification is shown in the table above.
(a) ADDITIONAL REQUIREMENT: Under this provision, PRODUCT CONTAINING USED OIL SHALL NOT BE SUPPLIED.
(b) HIGHLIGHT OF SPECIFICATION REQUIREMENTS:
(1) SULFUR REQUIREMENT: As per D396, No. 2 S500, the maximum allowable sulfur content for Burner Oil, Grade No. 2 S500 shall be 0.05 weight percent.
(2) DYE REQUIREMENT: Under United States regulations, Grade No. 2 S500 is required by 40 CFR Part 80 to contain a sufficient amount of the dye Solvent Red 164 so its presence is visually apparent. At or beyond terminal storage tanks, they are required by CFR Part 48 to contain the dye Solvent Red 164 at a concentration spectrally equivalent to 3.9 pounds per thousand barrels of the solid dye standard Solvent Red 26. As a means of identification, the Internal Revenue Service (IRS) requires that a red dye, must be added to all nontaxable diesel and all nontaxable kerosene used for purposes other than military jet fuel.
(c) BLENDING REQUIRMENT: Blending of various compatible grades of burner oil to produce an intermediate grade is permitted, however, such blending shall be accomplished by mechanical mixing or agitation in a tank, or by in-line blending, prior to loading the product into transport equipment, and the resultant product must meet all the requirements of the grade produced (Fuel Oil, Burner No. 2 S500).
Date: 2016.12.22 15:12:20 -05'00'
Date: 2016.12.28 09:09:17 -05'00'
Date: 2017.01.06 16:54:55 -05'00'
DEFENSE LOGISTICS AGENCY ENERGY Page 1 of 2
C16.69-2 GASOLINE AUTOMOTIVE, UNLEADED, MIDGRADE (MUM) (DLA ENERGY SEPTEMBER 2023)
9130-01-272-0983 Gasoline, Midgrade Unleaded MUM
Supplies delivered under this contract shall conform to all Federal, State, and local environmental requirements applicable to the geographic location of the receiving activity on the date of delivery. This includes delivery of fuel and documentation in a manner consistent with existing or future Title V (Clean Air Act) Permits. In the event that a Federal, State, or local environmental requirement is more stringent than a similar requirement in a fuel specification contained in this contract, the Contractor shall deliver product that complies with the more stringent requirement. Product that fails to meet the more stringent environmental requirement will be considered to be a nonconforming supply. All supplies furnished under this contract shall fully meet the requirements of the applicable specification(s) as cited below.