Attachment D8_ Drawings 8 of 12.pdf
PDF 19 MB Posted
- Attached to
- Z2DZ--644-20-201 EHRM Phoenix Construction Federal contract opportunity
- Solicitation number
- 36C26221B0007_1
About this file
This document provides details for a federal solicitation seeking construction services. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22 is soliciting bids for Project 644-20-201 "Electronic Health Records Modernization (EHRM) Infrastructure Upgrades" at the VA Phoenix Healthcare System located in Phoenix, Arizona. The project scope includes general construction, alterations, mechanical, electrical work and utility systems with a budget between $10-20 million. All work must be performed according to specifications and drawings and applicable building codes. This project is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses listed on the Vendor Information Pages database. An Invitation for Bid will be issued on June 3, 2021 via sam.gov and a mandatory site visit will be scheduled. Interested parties should contact the named contracting specialist.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C26221B0007 AMENDMENT 0004 7-13-21.pdf | ||
| 36C26221B0007 AMENDMENT 0003 7-07-21.pdf | ||
| AMENDMENT 0003 - ATTACHMENT MI903 - Mechanical and Electrical Schedules.pdf | ||
| 36C26221B0007 AMENDMENT 0002 7-02-21.pdf | ||
| 36C26221B0007 AMENDMENT 0001 6-30-21.pdf | ||
| Attachment A_ Campus Map.pptx | PPTX presentation | |
| Attachment D1_ Drawings 1 of 12.pdf | ||
| Attachment D12_ Drawings 12 of 12.pdf | ||
| 36C26221B0007_1.docx | DOCX document | |
| Attachment D6_ Drawings 6 of 12.pdf | ||
| Attachment D7_ Drawings 7 of 12.pdf | ||
| Attachment C_ Specifications.pdf | ||
| Attachment B_ Wage Determination.pdf | ||
| Attachment D2_ Drawings 2 of 12.pdf | ||
| Attachment D3_ Drawings 3 of 12.pdf | ||
| Attachment D5_ Drawings 5 of 12.pdf | ||
| Attachment D9_ Drawings 9 of 12.pdf | ||
| Attachment D4_ Drawings 4 of 12.pdf | ||
| Attachment D10_ Drawings 10 of 12.pdf | ||
| Attachment D11_ Drawings 11 of 12.pdf |
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans
Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMP
321 4 5 6 7 8 9 10
EHRM INFRASTRUCTURE
UPGRADES
644-20-201
Revisions: Date:
TL 602.606.7432
Phoenix, AZ 85012
3300 N. Central Ave, STE 1520 www.dheengineering.com
Job Number: 00961.00
Concourse Federal Group 123 S. Royal Street Alexander, VA 22314
04.01.2021 JLZG
NATHAN J.
JONES
A
R I Z O N A U
S
A
R eg st e r ed
E
R
IT
I
D a t
S e d
C
A T E N
O e i gn _ _ _ _ _ _ _ _ _
F C
Expires 06-30-2023 i Pr o ession f al Engneer i
(M e hanica c l)
47914
04 01
A
R I Z O N A U
S
A
R eg st e r ed
E
R
IT
I
D a t
S e d
C
A T E N
O e i gn _ _ _ _ _ _ _ _ _
F C
Expires 03-31-2024 i Pr o ession f al Engneer i
ZACHARY
GOLDSWORTHY
(E l c t rica e l)
72942
04 01
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
PVAHCS - Carl T Hayden Medical Center
650 E Indian School Road Phoenix AZ 85012
ELECTRICAL PANEL SCHEDULES
01-EK610
04.28.202105.26.2021 SHEET 195 of 421
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans
Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMP
321 4 5 6 7 8 9 10
EHRM INFRASTRUCTURE
UPGRADES
644-20-201
Revisions: Date:
TL 602.606.7432
Phoenix, AZ 85012
3300 N. Central Ave, STE 1520 www.dheengineering.com
Job Number: 00961.00
Concourse Federal Group 123 S. Royal Street Alexander, VA 22314
04.01.2021 JLZG
A
R I Z O N A U
S
A
R eg st e r ed
E
R
IT
I
D a t
S e d
C
A T E N
O e i gn _ _ _ _ _ _ _ _ _
F C
Expires 03-31-2024 i Pr o ession f al Engneer i
ZACHARY
GOLDSWORTHY
(E l c t rica e l)
72942
04 01
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
PVAHCS - Carl T Hayden Medical Center
650 E Indian School Road Phoenix AZ 85012
ELECTRICAL PANEL SCHEDULES
01-EK611
04.28.202105.26.2021 SHEET 196 of 421
04.28.202105.26.2021 SHEET 197 of 421
04.28.202105.26.2021 SHEET 198 of 421
1 7 11 20 2118.6
SHOP
ELECTRICAL
O120
STORAGE
O119
STORAGE
O504
STOR
O104
ELEV
T-3
SHOP
O121
HKS
O103
Room D209K
Room D209M
Room D209N
MACH RM
CORRIDOR
O117B
ELEV
T-4
ELECTRICAL
O501
COMPRESSOR
STOR
O106A
STUDIO
O106C
OFFICE
O106B
ALL-PURPOSE
O106K
RECEPTION
O106
TOILET
0106D
CORRIDOR
O106F
OFFICE
O106H
STORAGE
O106G
STORAGE
O302
AREA WAY
D209JJ
Room
BK02
STAIR 10
Room KB04 Room
KB05
MECHANICAL
BK01
Room
D209QQ
STAIR
102A
Room
Room
D209TT
SHOP
D08
SHOP
D111
STORAGE
FIRE ALARM
D06
SHOP
C1A
CART WASH
D05
OFFICE
D05A
SHOP
D07
OFFICE
D010
OFFICE
D07A
CENTRAL LINEN
OFFICE
O116A
STAIR
B-6
LOCKER
O112
ELEV
TOILET
D09B
SATALITE
O106I
OFFICE
O106J
STORAGE
STORAGE
HKS STORAGE
ELEV EQUIP
C2B
NORMAL POWER
B001
UTILITY SPACE
C002
ELECTRICAL ROOM
B009
Room D04B
ELEC
ELEC
D01A
STAIR 1
CORRIDOR
ABAN TR
D01B
Room ELEVATORS ELEV EQUIP
ELEC
PROSTHETICS
STORAGE
STAIR
ELECTRICAL
D03
GENERATOR
D02
SWITCHGEAR
D02A
CORRIDOR
Room
BK103
CORRIDOR
TUNNEL TO BLDG 02
LOBBY
ESSENTIAL POWER
B002
Room D04A
PUMP ROOM
CORRIDOR
O117A
MULTI-WORK
O106E
Room
RB06
TR MECH
TRS-000B
DIGITAL RM
O106F
LOCKER
D09A
TOILET
D09B
LOBBY
BK
CORRIDOR
O117C
CORRIDOR
O117D
CORRIDOR
O117
TR ELEC
TRS-000C
TR
TRS-000A
ELEVATOR LOBBY
C615F
01-TN401
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR D01B - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-000A
AVERAGE DISTANCE IS FROM NEW TR
TOTAL CABLES 192
AVERAGE DISTANCE/CABLE 274'
G
L
A
S
R
BLDG 01
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans
Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET OF
BI
M
Ph oe ni x
EH
R M
/6
-2 0-
BL
D
G
1_ A.
rv t
9/ 6/
:3
5:
P M
01-TN100
TELECOMMUNICATIONS PLAN
BASEMENTConcourse Federal Group
11755 Wilshire Blvd., Suite 1250 Los Angeles, CA 90025
EHRM INFRASTRUCTURE
UPGRADES 01
02.05.2021
PVAHCS - Carl T Hayden Medical Center 650 E Indian School Road Phoenix AZ 85012
644-20-201
10 10 20 30 40 50 60 3/64" = 1'-0"
FEETSCALE
10 10 20 30 40 50 60 3/64" = 1'-0"
FEETSCALE
Revisions: Date: CCSTEAM
4365 E. PECOS RD. - GILBERT, AZ. 85295
(602) 619-9710 - VOICE
OLYMPUS CONSTRUCTION MANAGEMENT
04.01.2021
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
KEYED NOTES:
EXISTING TR TO BE ABANDONED. EXISTING ENTRANCE FACILITIES AND
COPPER BACKBONE TO REMAIN. EXISTING FLOOR SERVING CABLING TO BE
RE-ROUTED TO NEW TRS-000A
EXISTING OVERHEAD PATHWAY.
GENERAL NOTES:
DIVISION 27 CONTRACTOR TO COORDINATE ALL CUTOVERS WITH OI&T DEPARTMENT
PRIOR TO DEMOLITION OR INSTALLATION. ALL EXISTING DATA CABLES AND CIRCUITS
MUST REMAIN IN PLACE AND OPERATION UNTIL FINAL CUT-OVER TO ANY NEW OR
REPLACEMENT CABLING.
EXISTING OVERHEAD PATHWAYS (CABLETRAY, CONDUIT, SLEEVING) TO BE USED.
INSTALL FIRE-RATED SLEEVES WHEN PENETRATING FIRE-RATED WALLS.
IT IS THE RESPONSIBILITY OF THE DIVISION 27 CONTRACTOR TO INVESTIGATE AND
LOCATE (TONE AND TEST) ALL EXISTING CATEGORY 5 STATION CABLING; IF APPLICABLE.
DIVISION 27 CONTRACTOR TO REPLACE ALL WIRELESS ACCESS POINTS WITH CATEGORY
6A CABLING. PROVIDE AND INSTALL TWO (2) CAT6A CABLES (ONE PUBLIC, ONE HOSPITAL
NETWORK) WITH A 20' LOOP AT STATION END TO EACH DEVICE. IT IS THE
RESPONSIBILITY OF THE DIVISION 27 CONTRACTOR TO INVESTIGATE AND LOCATE ALL
EXISTING WIRELESS ACCESS POINT STATION CABLING. DIVISION 27 CONTRACTOR TO
PROVIDE HEAT MAPPING SHOWING NEW WIRELESS LOCATIONS AND COVERAGE.
DUE TO DIFFERENCES OF AGE AND CONSTRUCTION OF EXISTING BUILDINGS - DIVISION
27 CONTRACTOR TO BE AWARE OF CHALLENGES SUCH AS HORIZONTAL OBSTRUCTIONS
AND CLEAR WORKING SPACE ABOVE CEILINGS. SURFACE MOUNT NON-METALLIC
RACEWAY MAY BE USED ONLY WHERE IT IS IMPOSSIBLE TO FEED NEW CABLING VIA
FISHED WALLS OR OTHER METHODS AND APPROVED BY OI&T DEPARTMENT.
EXISTING STATION LOCATIONS ARE DIAGRAMMATIC IN NATURE AND REPRESENTATIVE
OF FIELD INVESTIGATION AT AN EYE LEVEL ONLY. ALL STATION QUANTITIES TO BE
VERIFIED PRIOR TO AREA BEING REMODELED AND CONFIRMED WITH OI&T PRIOR TO
INSTALLATION.
1" = 300'-0"
PLAN KEY
TELECOM AND SECURITY PLAN -
BASEMENT
05.26.2021 SHEET 199 of 421
TR RM K132 SERVING AREA
TR
R
M K
SE
RV
IN
G
AR
EA
TR
R
M
1A
S
ER
VI
N
G
AR
EA
TR
R
M
1A
S
ER
VI
N
G
AR
EA
TR
R
M
1A
S
ER
VI
N
G
AR
EA
TR RM C185 SERVING AREA
TR RM E104D SERVING AREA
TR
R
M
SE
RV
IN
G
AR
EA
TR
R
M
9A
S
ER
VI
N
G
AR
EA
TR RM 1151 SERVING AREA
G
L
A
11 17
18.6
S
R
TR
K132
TLT
GYN EXAM 1
Room 2234D
Room 2234E
Room 2234F
STORAGE
D105A
ELEC
D100A
ELEC
D100STAIR 1
-CONF ROOM
Room 2234L
OFFICE
D104A
STOR
ED-12
C164
ED-15
C162
ED-01
C182
MEDS
C150A
Room
2234T ED-02
C180
STAIR 18
Room 2234Z
Room
-STAIR #2
VEST
GROUP THERAPY
D134
HAC
D142
STAF TLT
D136
UTIL
D139 COMM
D141
ELEC
D137
COMM
D139
ABAN TR
D138
KITCHEN
D134CCONF
D134A
TRAINEE OFFICE
D134B
WORK ROOM
D134L
INTERVIEW
D135
CLINICAL PSY
D134F
CORR
GROUP CONFERENCE
D154
WAITING
D157
TLT
D152
TLT
D153
CLERK/MAIL
D156A
OFFICE RN
D154A
OFFICE SG
D154B
OFFICE
D155
TRIAGE
D144
TRIAGE
D147
TRIAGE
D146
TRIAGE
D147
TRIAGE OFF
D148
TRIAGE OFF
D150
TRIAGE OFF
D149 OFFICE SHARE
D151
FEMALE TOILET
D158
COUNCIL OFF
D133
COUNCIL OFF
D132
COUNCIL OFF
D131
CORR
SUB WAIT
D130
COUNCIL OFF
D127
COUNCIL OFF
D128
COUNCIL OFF
D129
COUNCIL OFF
D124
COUNCIL OFF
D125
COUNCIL OFF
D126
COUNCIL OFF
D121
COUNCIL OFF
D112
COUNCIL OFF
D118
COUNCIL OFF
D119
COUNCIL OFF
D120
COUNCIL OFF
D115
COUNCIL OFF
D116
COUNCIL OFF
D117
COUNCIL OFF
D113
COUNCIL OFF
D114
COUNCIL OFF
D123
CORR
COUNCIL OFF
D112
CORR
SUB WAIT
D111
BREAK ROOM
D106R W TLT
D106Q
ARMORY
D106N
SHWR
D106P
M TLT
D106O
COUNSEL OFF
D108
COUNCIL OFF
D109
LOCKERS
D106J HOLD
D106G
HOLD
D106H
OFFICE
D106F
Room
OFFICE
D106A
OFFICE
D106C
OFFICE
D106B
CORR
VIDEO
D106D
LEAD CLERK/MMS
D106E
ISOLATION
C126
ED-22
C127
P TLT
C128
HAC
C124
ABAN TR
C129
TRIAGE
C140
CLEAN
C174
ROOM
C179 CORRIDOR
C100HED-04
C175
ED-03
C177
DECON
C-173
TLT
C166
ED-11
C165
ED-14
C163
ED-16
C161
BREAK ROOM &
LOCKERS
C117
STAFF TLT
C116A
OFFICE
C116
OFFICE
C114A
OFFICE
C114B
OFFICE
C114C
OFFICE
C114D
HAC
C113
OFFICE DERM
C112
OFFICE/DERM
C111
OFFICE/DERM
C109
P TOILET
C110
ED ROOM
C100
EXAM
C101
OFFICE/DERM
C102
OFFICE/DERM
C103
OFFICE/DERM
C104
OFFICE/DERM
C105
DERM TREATMENT
C106
OFFICE/DERM
C107
OFFICE/DERM
C108
ELEC
C135
SOIL UTIL
C135
EQUIP STORAGE
C138
OFFICE/DERM
C118
OFFICE/DERM
C120A
SF TLT
C134A
OFFICE/DERM
C119
ELEC
C132A
CLEAN/MEDS
C131
PHOT THERAPY
C123
OFFICE/DERM
C122
BREAK
C121
STAIR3
Room C1??
ED-10
C167
ED-09
C168
Room C169
TOILET
C170A
ED-07
C170
ED-05
C172
ED-06
C171 ED-18
C186
ED-17
C160
TR
C185
P TOILET
C183
NURSE
C132
ADMISSION
C125
ELEGIBILITY
E101
TOILET
E103
TOILET
E102
TR
TRS-100A
OFFICE
D102
OFFICE
D103
OFFICE
OFFICE
E104A
MEN' TOILET
WOMEN'S TOILET
WALK-THRU REFER
FREEZER
REFER
MAIL ROOM
AREA WAY
BIO-MEDICAL SHOP
1163A
OFFICE
1163B
OFFICE
1163C
OFFICE
OFFICE
UN-NAMED
CLOSET
UN-NAMED
1124B
UN-NAMED
1122A
UN-NAMED
HOME CARE SERV
OFFICE
OUT-PATIENT DINING
REFER
1153A
OFFICE
1153C
TR 105
1151 OFFICE
Room
Room
HKC
1150A
OFFICE
1607D
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
RECEPTION
OFFICE
OFFICE
OFFICE
1607E
OFFICE
1607B
DATA CENTER
KITCHEN
1606B
OFFICE
HKC
Room 1606A
STAIR
ABAN TR
1411 PROCEDURE
E131 OFFICE
E122
OFFICE
E123
POLICE
OFFICE
WATER TREAT
1403B
HKC
1425A
OFFICE
1124A
STERILE STAGING
STERIL AREA
Room
CART
1403D
ELECT
CARTS
OFFICE
DECONTAM
CLOSED STORAGE
FOOD REFER
OFFICE
1153D
OFFICE
1153E
OFFICE
1153FOFFICE
STAIR
OFFICE
STOR
1102A
HKS
1102A
OFFICE
1148C
OFFICE
1148D-1
CABLE ROOM
1148B
OFFICE
1148B
OFFICE
STAIR
PIV WAITING
1148D-2
TELEPHONE ROOM
101-1
OFFICE
PIV OFFICE
PIV
CANTEEN STORAGE
OFFICE
OFFICE
HKC
TOILET
OFFICE
OFFICE
Room
-PRAYER ROOM
VESTIBULE
STORAGE
CHAPEL
HALLWAY
VEST
OFFICE
1706A
OFFICE
FOOD SERVICE
WAREHOUSE
W105
CONFERENCE
C121
VEST
OFFICE
CLOSET
1602A
OFFICE
OFFICE
OFFICE
OFFICE
UN-NAMED
1124C
UN-NAMED
MORGUE
Room
MORGUE
STORAGE
SPD RECIEVING
VEST
TLT
1130A
PHARMACY
RECEIVING
Room
BREAK ROOM
TLT
1130B
VEST
CORRIDOR
FREEZER
SINK AREA
KITCHEN
Room
TLT
TLT
Room
REFER
MAIN KITCHEN
FLAMABLE GAS
FLAMABLE LIQUID
Room
CONTROL ROOM
REFER
REFER
1302 WASH
COOLER
1509A
COOLER
WAREHOUSE
CORRIDOR
WAREHOUSE
W104
OFFICE
W101
Room
Room W102
Room
HRS
STAIR
TR
1321A
LOBBY
K105
LOBBY
K101
HKC
H103
STOR
K120A
TLT
K117A
STORAGE
K120
2 BED
K117
TLT
K113A
TLT
K115A
2 BED
K115
2 BED
K113
CONFERENCE ROOM
K112
OFFICE
K102
CANTEEN STORAGE
K104
VEST
STAIR 10
SEATING
SEATING
TOILET
OFFICE
RECREATION ROOM
L101
RETAIL STORE
OFFICE
L101A
Room L114A
TLT
L118A
TLT
L110A
TLT
L113A
TLT
L112A
TLT
L111A
OFFICE
1148G
LOUNGE
K133
STORAGE
K140
TLT
K135A
1 BED
K135
TLT
K137A
TLT
K139A
1 BED
K137
1 BED
K137
OFFICE
K130
MEDS
K127
TEL
L122
Room L123
1 BED
L124
1 BED
L127
TLT
L124A
TLT
L127A
1 BED
L128 TLT
L128A
STAIR
TLT
L126A
HOSPICE LOUNGE
L125
2 BED
L126
TLT
L121A
OFFICE
L121
2 BED
L120
TLT
L120A
OFFICE
L119
TLT
L117A
2 BED
L117
ELEC
L115
TLT
L116A 2 BED
L116
COMPUTER ROOM
L111
2 BED
L118
2 BED
L114
2 BED
L113
VEST
OFFICE
L103
OFFICE
L104
OFFICE
L107
OFFICE
L109
OFFICE
L108
CORRIDOR
OFFICE
L105A
M TLT
L105
F TLT
L106
SMOKING RM
L102B1
Room L105B
DINING ROOM
L102
OFFICE
K108
STORAGE
K108A
TOILET
K109
ELEC
K110
PATIENT LAUNDRY
K111
OFFICE
K102A
TLT
K114A
Room TLT K116A
2 BED
K116
2 BED
K114
2 BED
K118
TLT
K118A SOILED
K119
4 BED
L110
STAFF
K122CLEAN
K121
TUB ROOM
K123
TLT
K123A
BREAK RM
K134
2 BED
K136
TLT
K136A
TLT
K138A
2 BED
K138 STAIR
TLT
K131A
2 BED
K131
TLT
K129A
2 BED
K129
TLT
K125A
2 BED
K125
2 BED
K124
TLT
K124A
CLEAN SUPPLY
HKC
K128
2 BED
L112
CLEAN EQUIP
1403A
TOILET
TELEPHONE
OPERATORS
E100A
TRAINING ROOM
E120
OFFICE
FAMILY THERAPY
CLOSET
NURSE CASE WOR'R
POLY TRUAMA
OFFICE
OFFICE
CORRIDOR
MP EXAM 6
TLT
SPEC EXAM 2
MP EXAM 2
CORRIDOR
CLN STOR 2
1217A
NURSE STA
MP EXAM 7
SOIL STOR
1217B
GYN EXAM 4
GYN EXAM 3
PROCEDURE ROOM
GYN EXAM 2
GYN EXAM 6
GYN EXAM 5
FAN RM
STAIR
PROJECT MANAGER
PHYS
READING RM 1
MAMO
READING RM 2
TLT
CLN STOR 1
JANITOR
CORRIDOR
ABAN TR
MEN
1219B
WOMENS HEALTH
WOMEN
1229A
PSYCH/PSYCH
ASSISTANT
PHARM
PROG ASSIST
PROG MANAGER
ADVOC/SOCIAL
OFFICE
OFFICE
1148A
TOILET
OFFICE
1147A
OFFICE
OFFICE
OFFICE
OFFICE
BREAK ROOM
PHYS
MP EXAM 2
MP EXAM 1
ELECT
MP EXAM 3
MP EXAM 4
MP EXAM 5
MP EXAM 1
SPEC EXAM 1
VEST
ULTRA
STEREO TABLE
CORRIDOR
WAITING AREA
D105
TREATMENT
C139D
TREATMENT
C139C
Room C189
NURSE STA
C150
CORR
C150B
CORR
C100L
CORR
C100K
CORR
C100J
CORR
C100G
CORR
C100F
ED-XX
C139E
OFFICE
D106I
OFFICE
D106K
OFFICE
D106
SUB WAIT
261A04.04
CORR
D100A
CORRIDOR
CORR
1024A
Room
CORR
CORR
CORR
STOR
E124
PLATFORM
VENDING
POST DEPLOY
MODALITY
E128
OCCUPATIONAL
THERAPY
E1291
ELEC
E140
ELEC
E145
TLT
E133
COPY CTR
E138
S TOILET
E133A
ADL
E132
CONSULT
E137
EXAM
C110
PAT TOILET
C109
RECEPTION
C102
RECEPTION WAITING
C100
CORRIDOR
C101
STAFF LOUNGE
C104
CORRIDOR
C103
CORRIDOR
C108
EXAM
C111
PAT TOILET
C112
NURSE STATION
C107
MULTIPURPOSE
C106
OFFICE
C105
ESCORT STAGING
C117
SOILED UTILITY
C115
TOILET
C114
CLEAN UTILITY
C116
INFO DESK
C118
EXAM
C113
PROCEDURE
E125
CORRIDOR
ALCOVE
1321B
FOOD STOR
Room
PREP AREA
STORAGE
BREAK
GALLERY
E100
CORR
CORRIDOR
CORRIDOR
CORRIDOR
RECEPTION
D156
VRC
SERVICE AREA
1406B
HKC
1403C
BREAK ROOM
E100B
CORRIDOR
TR
1221A
TR MECH
TRS-100B
TR ELEC
TRS-100C
ELEVATOR LOBBY
C615E
HALLWAY
TOILET
Room
NURSE STA
C120
N. TOWER TR
(2-4) ABOVE
01-TN404
01-TN401
01-TN405
01-TN404
01-TN404
01-TN404
01-TN405
EMERGENCY DEPT
JADE OPAL CLINIC
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-100A
AVERAGE DISTANCE IS FROM NEW TR
TOTAL CABLES 192
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR D138 - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-100A
AVERAGE DISTANCE IS FROM NEW TR
TOTAL CABLES 132
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR C129 - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-100A
AVERAGE DISTANCE IS FROM NEW TR
TOTAL CABLES 262 CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR K132 - EXPAND IN PLACE
AVERAGE DISTANCE/CABLE 245'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR 1411 - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR 1609A
AVERAGE DISTANCE IS FROM NEW TR
TOTAL CABLES 456
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR 1151 - REMEDIATE IN PLACE
AVERAGE DISTANCE/CABLE 276'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR 1321A - REMEDIATE IN PLACE
AVERAGE DISTANCE/CABLE 160'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
NEW TR 1221A - RELOCATE FROM 1220
AVERAGE DISTANCE/CABLE 165'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR C185 - REMEDIATE IN PLACE
AVERAGE DISTANCE/CABLE 200'
TR C221A
ABOVE.
FIBER PATH 'B'
TO BUILDING 8
TO NEW FIBER
EQUIPMENT
RACKS
AVERAGE DISTANCE/CABLE 245'
AVERAGE DISTANCE/CABLE 255'
TOTAL CABLES 176
AVERAGE DISTANCE/CABLE 255'
AVERAGE DISTANCE/CABLE 255'
TOTAL CABLES 171
TOTAL CABLES 364
TOTAL CABLES 288
TOTAL CABLES 312
BLDG 01
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans
Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET OF
BI
M
Ph oe ni x
EH
R M
/6
-2 0-
BL
D
G
1_ A.
rv t
9/ 6/
:3
5:
P M
01-TN101
TELECOMMUNICATIONS PLAN
1ST FLOORConcourse Federal Group
11755 Wilshire Blvd., Suite 1250 Los Angeles, CA 90025
EHRM INFRASTRUCTURE
UPGRADES 01
PVAHCS - Carl T Hayden Medical Center 650 E Indian School Road Phoenix AZ 85012
644-20-201
10 10 20 30 40 50 60 3/64" = 1'-0"
FEETSCALE
Revisions: Date: 02.05.2021 CCSTEAM
4365 E. PECOS RD. - GILBERT, AZ. 85295
(602) 619-9710 - VOICE
OLYMPUS CONSTRUCTION MANAGEMENT
04.01.2021
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
KEYED NOTES:
EXISTING TR TO BE ABANDONED. EXISTING ENTRANCE FACILITIES AND
COPPER BACKBONE TO REMAIN. EXISTING FLOOR SERVING CABLING TO BE
RE-ROUTED TO NEW TRS-100A
EXISTING OVERHEAD PATHWAY.
FIBER PATHWAY 'A' TO NORTH TOWER. REF T-601 FOR RISER DIAGRAM
FIBER PATHWAY 'A' TO SOUTH TOWER. REF T-601 FOR RISER DIAGRAM
FIBER PATHWAY 'B' TO N&S TOWERS. REF T-601 FOR RISER DIAGRAM
EXISTING TR TO BE ABANDONED. EXISTING ENTRANCE FACILITIES AND
COPPER BACKBONE TO REMAIN. EXISTING FLOOR SERVING CABLING TO BE
RE-ROUTED TO NEW TR WITHIN DATA CENTER 1609.
NEW TR REPLACING TR 1220. EXISTING ENTRANCE FACILITIES AND COPPER
BACKBONE TO REMAIN AT TR 1220.
FIBER BACKBONE CABLING A & B TO BULDING 8
GENERAL NOTES:
DIVISION 27 CONTRACTOR TO COORDINATE ALL CUTOVERS WITH OI&T DEPARTMENT
PRIOR TO DEMOLITION OR INSTALLATION. ALL EXISTING DATA CABLES AND CIRCUITS
MUST REMAIN IN PLACE AND OPERATION UNTIL FINAL CUT-OVER TO ANY NEW OR
REPLACEMENT CABLING.
EXISTING OVERHEAD PATHWAYS (CABLETRAY, CONDUIT, SLEEVING) TO BE USED.
INSTALL FIRE-RATED SLEEVES WHEN PENETRATING FIRE-RATED WALLS.
IT IS THE RESPONSIBILITY OF THE DIVISION 27 CONTRACTOR TO INVESTIGATE AND
LOCATE (TONE AND TEST) ALL EXISTING CATEGORY 5 STATION CABLING; IF APPLICABLE.
DIVISION 27 CONTRACTOR TO REPLACE ALL WIRELESS ACCESS POINTS WITH CATEGORY
6A CABLING. PROVIDE AND INSTALL TWO (2) CAT6A CABLES (ONE PUBLIC, ONE HOSPITAL
NETWORK) WITH A 20' LOOP AT STATION END TO EACH DEVICE. IT IS THE
RESPONSIBILITY OF THE DIVISION 27 CONTRACTOR TO INVESTIGATE AND LOCATE ALL
EXISTING WIRELESS ACCESS POINT STATION CABLING. DIVISION 27 CONTRACTOR TO
PROVIDE HEAT MAPPING SHOWING NEW WIRELESS LOCATIONS AND COVERAGE.
DUE TO DIFFERENCES OF AGE AND CONSTRUCTION OF EXISTING BUILDINGS - DIVISION
27 CONTRACTOR TO BE AWARE OF CHALLENGES SUCH AS HORIZONTAL OBSTRUCTIONS
AND CLEAR WORKING SPACE ABOVE CEILINGS. SURFACE MOUNT NON-METALLIC
RACEWAY MAY BE USED ONLY WHERE IT IS IMPOSSIBLE TO FEED NEW CABLING VIA
FISHED WALLS OR OTHER METHODS AND APPROVED BY OI&T DEPARTMENT.
EXISTING STATION LOCATIONS ARE DIAGRAMMATIC IN NATURE AND REPRESENTATIVE
OF FIELD INVESTIGATION AT AN EYE LEVEL ONLY. ALL STATION QUANTITIES TO BE
VERIFIED PRIOR TO AREA BEING REMODELED AND CONFIRMED WITH OI&T PRIOR TO
INSTALLATION.
1" = 300'-0"
PLAN KEY
TELECOM AND SECURITY PLAN -
1ST FLOOR
05.26.2021 SHEET 200 of 421
TR
R
M K
SE
RV
IN
G
AR
EA
TR
R
M N
O
RT
H
TO
W
ER
S
ER
VI
N
G
AR
EA
TR
R
M N
O
RT
H
TO
W
ER
S
ER
VI
N
G
AR
EA
TR
R
M
CD
8C
S
ER
VI
N
G
AR
EA
G
L
A
11 17
B.4
18.6
S
H.9
G.8
D.9
C.6
R
ABAN TR
2234A
Room C130
ABAN TR
C221A RESIDENTS
C221
STORAGE
C221
WHIRLPOOL BATH
C224
Room C218 Room C219
OFFICE
C226
MEDS
C209
MED STOR
OFFICE
C228
Room C226A
Room C226
VASCULAR MEDICINE
TOILET
D222B
ULTA SOUND
D222
VASCULAR MEDICINE
VASCULAR MEDICINE
HOT ROOM
D225B
STOR
D227
EQUIP RM
D225C
TREADMILL
D237A
CONTROL RM
D237
CT SCAN
D237C
CHANGE
D238A
TOILET
D238A
STAIR 2
WRK STA 2
D239 CAT SCAN
D241
EXAM
D242A
EXAM
D242B
OFFICE
D242C
Room C250
TOILET
D234C
WAITING
D242D
TECH
D242
X-RAY
D234B
CONTROL ROOM
D243
TOILET
D245A
Room D245B
FLUROSCOPY
D245
HKC
D224
RECPTION &
RECORDS
D210
ABAN TR
D241AEXAM
D236
ELEC
CD6A
Room
CD6B
DUCT SHAFT
D236A
Room C272
ULTRASOUND
D221
OFFICE
D220A
SHAFT
TOILET
D206
STOR
D210A
RADIOLOGY HOLDING
D212
CORRIDOR
2CD-3
VIEWING AREA
D216
HALL
D217
TOILET
D217A
HALL
D211
CONTROL RM
D210A
X-RAY SPECIAL
PROCEDURE
D213
TOILET
C200A
TOILET
C203A
TOILET
C206A
STAIR 3
Room C212
ICE
C213TOILET
C214A
1 BED
C214
TOILET
C218A
TOILET
C217A
COMPUTER RM
C217
4 BED
C215
TOILET
C215A
STORAGE
C216
TOILET
C216A
OFFICE
C315
OFFICE
C205
BREAK ROOM
C230
STORAGE
C202
OFFICE
C203A OFFICE
C234
ELEC
C323
CLEAN UTILITY
D201
STAIR 1
C326
TOILET
D203
UTILITY
D202
ELEC
C330
OFFICE
D247
OFFICE
D248
OFFICE
D204
HALLWAY
C337
X-RAY SPECIAL
PROCEDURE
D209
EQUIP
D209A
1 BED
C203
2 BED
C207
2 BED
C206
1 BED
C203
4 BED
C218
TOILET
C219A
1 BED
C219
1 BED
C220
TOILET
C220A
HKC
C222
STOR
C223
4 BED
C225
TOILET
C225A
TOILET
C227A
2 BED
C227
CHART RM
C229
1 BED
C231
STOR
D2149I
OFFICE
D248B
Room
C374 OFFICE
D248C
OFFICE
D249D
INTERN ED
D249H
BRK RM
D249H
OFFICE
D249G
OFFICE
D249E
OFFICE
D249F
TOILET
C233
PASSAGEWAY
C200
RADIO GRAPHIC
D219
WAITING
OFFICE
D234
STOR
D233
LOCKER
E202
CHEM
E201
FLAMABLE STORAGE
E201A
Room C394
STORAGE
E223
STAIR 5
C397
BREAK RM
E203
LAB IMMUNOLOGY
E204
HISTOLOGY LAB
E205A
OFFICE
E205C
HISTOLOGY LAB
E205
TOILET
E210
OFFICE
E209
OFFICE
E208
OFFICE
E212
CONFERENCE
E211
CORRIDOR
STORAGE
C414
COPIER
E207
ELEC
E213
OFFICE
E214
STAIR 6
C423
HEMATOLOGY LAB
E215
OFFICE
E215B
STOR
E216
Room C430
SHAFT
OFFICE
OFFICE
OFFICE
LAB
Room C438
STOR
STOR
Room 2306A
OFFICE
PROVIDER STATION
Room C445
Room C446
Room C447
PROVIDER ONCALL
2313A
PROVIDER ONCALL
2313B
BREAKROOM
2318 HKC
TOILET
BREAKROOM
2313C
PATIENT
2321 TOILET
OFFICE
OFFICE
LOBBY
STAIR 8
C460
CORRIDOR
TOILET
PATIENT 2-BED
PATIENT 3-BED
PATIENT 3-BED
C465
TOILET
HALL
PHARMACY
PATIENT 3-BED
TOILET
2338A
REFRIG ROOM
DIRTY UTILITY
PATIENT 3-BED
COPIER
Room C481
P TOILET
P TOILET
NURSING STATION
PATIENT
OFFICE
OFFICE
TOILET
Room
TOILET
STAIR 9
TOILET
2341A
CLEAN LINEN
CLEAN STORAGE
2329A
PATIENT 3-BED
PATIENT 2-BED
OFFICE
OFFICE
OFFICE
OFFICE
TOILET
2144A
OFFICE
Room C507 Room C508
OFFICE
OFFICE
OFFICE
EXAM
EXAM
TOILET
BREAK
MINOR PORCEDURE
CORRIDOR
STOR
EXAM
ROOM
HKC
TOILET
WOUNDS
2202A
EXAM
Room C531
SOILDED
Room C533
OFFICE
STAIR 7
EXAM
EXAM
EXAM
EXAM
SUPPLY
CONSULTING
OFFICE
CORRIDOR
WAITING
TOILET
TOILET
2206A
PROCEDURE ROOM
HALLWAY
CLEAN
2204C Room
TOILET
2204E STOR
OFFICE
OFFICE
OFFICE
2131A
REFRIG
E200F
REFRIG
E200G
ELEC
E200D
ELEC
E200C
HKC
ELEC
CE1A
LAB
E200A
LAB
E200B
OFFICE
D254
EXAM SPEECH
D251B
LAB
E200
STOR
E200E
EXAM
2204D2Room
C583
OFFICE
2204D1
OFFICE
2204COFFICE
2204C2 TOILET
2204B
TOILET
2204A
HKC
K203
TOILET
K220A
TOILET
K217A
CONFERENCE
K220
TOILET
C596
TOILET
K215A
SHAFT
CORRIDOR
TOILET
L205A
TOILET
L209A
TOILET
L201A
TOILET
L204A
TOILET
L203A
TOILET
L202A
COMPUTER RM
L202
BREAK RM
K233
LAUNDRY
K240
TOILET
K235A
PATIENT RM
K235
TOILET
K237A
TOILET
K239A
PATIENT RM
K239
PATIENT RM
K237
OFFICE
K230
TEL
L213
E-9 C623
Room C624
PLANNING
L215
PLANNING
L218
TOILET
L215A
TOILET
L218A
PLANNING
L219 TOILET
L219A
STAIR
TOILET
L217A
WAITING
L216
PLANNING
L217
TOILET
L212A
Room L212
Room L211
TOILET
L211A
OFFICE
L210
Room C644
Room L208
ELEC
L206
TOILET
L207A Room
L207A
Room L203
Room L209
Room L205
Room L204
SHAFT
ELEC
K207
OCCUPATIONAL
THERAPY
K210
TOILET
K214A
TOILET
K216A
2-BED
K216
2-BED
K214
2-BED
K218
TOILET
K218A SOILED
K219
Room L201
S TOILET
K222CLEAN
K221
TUB ROOM
K223
TOILET
K223A
TR
K232
CONFERENCE
K234
TOILET
K236A
TOILET
K238A
PATIENT RM
K238 STAIR
TOILET
K231A
TOILET
K229A
TOILET
K225A
TOILET
K224A
CLN SUPPLY
K226
HKC
K228
PHYSICAL THERAPY
K205
LOBBY
K204
LOBBY
K201
STAIR 10
STOR
K210A
STOR
K205A
M LOCKER
K202
M TOILET
K208
STOR
K209
F LOCKER
K212
W TOILET
K211
OFFICE
K206
2-BED
K213
2-BED
K215
2-BED
K217
2 BED
K224
2 BED
K225
PATIENT RM
K229
PATIENT RM
K231
PATIENT RM
K236
MEDS
K227
C723
CORRIDOR
VMAC
L214
OFFICE
E222
TOILET
E221
ABAN TR
E202B
CORRIDOR
LOCKER
E220
LABORATORY
E219
ABAN TR
2CD8A
OFFICE
E215A
WRK STA 1
D240
CHART
2204F
COPIER
LACTATION ROOM
Room E201A
OFFICE
D249A
TOILET
2208A
OFFICE
D226
WAITING
D238B
CORRIDOR
2CD-6
CORRIDOR
2CD-7
CLEAN
C201
CONTROL
D219A
CONTROL
D205
NURSE STA
C208
STOR
E205B
TOILET
E224
NURSE STA
2KC26
F TOILET
K212A
M TOILET
K202A
ABAN TR
2212A
TR ELEC
TRS-200C
TR
TRS-200A
TR ELEC
TRN-200C
TR
TRN-200A
TR MECH
TRS-200B
TR MECH
TRN-200B
CORRIDOR
AC200
ELEVATOR LOBBY
C615D
WAITING
D210
CORRIDOR
CORRIDOR
D220
CORRIDOR
CORRIDOR
PUMP HOUSE 2
01-TN403
01-TN403
01-TN405
UNDER CONSTRUCTION
UNDER CONSTRUCTION
LAB
PA
TI
EN
T
RO
O
M S
- F U
LL
PA
TI
EN
T
RO
O
M S
- F U
LL
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR 2CD8A - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-200A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 285'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR D241 - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-200A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 285'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR C221A - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-200A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 285'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR K232 - EXPAND IN PLACE
AVERAGE DISTANCE/CABLE 210'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR 2212A - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRN-200A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 282'
TOTAL CABLES 312
TOTAL CABLES 176
TOTAL CABLES 192
TOTAL CABLES 193
TOTAL CABLES 184
BLDG 01
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans
Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET OF
BI
M
Ph oe ni x
EH
R M
/6
-2 0-
BL
D
G
1_ A.
rv t
9/ 6/
:3
6:
P M
01-TN102
TELECOMMUNICATIONS PLAN
2ND FLOORConcourse Federal Group
11755 Wilshire Blvd., Suite 1250 Los Angeles, CA 90025
EHRM INFRASTRUCTURE
UPGRADES 01
PVAHCS - Carl T Hayden Medical Center 650 E Indian School Road Phoenix AZ 85012
644-20-201
10 10 20 30 40 50 60 3/64" = 1'-0"
FEETSCALE
Revisions: Date: 02.05.2021 CCSTEAM
4365 E. PECOS RD. - GILBERT, AZ. 85295
(602) 619-9710 - VOICE
OLYMPUS CONSTRUCTION MANAGEMENT
04.01.2021
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
KEYED NOTES:
EXISTING TR TO BE ABANDONED. EXISTING ENTRANCE FACILITIES AND
COPPER BACKBONE TO REMAIN. EXISTING FLOOR SERVING CABLING TO BE
RE-ROUTED TO NEW TRS-200A
EXISTING TR TO BE ABANDONED. EXISTING ENTRANCE FACILITIES AND
COPPER BACKBONE TO REMAIN. EXISTING FLOOR SERVING CABLING TO BE
RE-ROUTED TO NEW TRN-200A
PROVIDE NEW 12" X 4" BASKET TYPE CABLETRAY IN CORRIDOR FROM NEW TR
ROOM AS SHOWN, CONNECT TO EXISTING. FIELD COORDINATE WITH OTHER
TRADES. CABLETRAY TO BE MOUNTED MINIMUM 6" ABOVE FINISHED CEILING
WITH TWO SIDES OF 12" CLEARANCE.
EXISTING OVERHEAD PATHWAY.
GENERAL NOTES:
DIVISION 27 CONTRACTOR TO COORDINATE ALL CUTOVERS WITH OI&T DEPARTMENT
PRIOR TO DEMOLITION OR INSTALLATION. ALL EXISTING DATA CABLES AND CIRCUITS
MUST REMAIN IN PLACE AND OPERATION UNTIL FINAL CUT-OVER TO ANY NEW OR
REPLACEMENT CABLING.
EXISTING OVERHEAD PATHWAYS (CABLETRAY, CONDUIT, SLEEVING) TO BE USED.
INSTALL FIRE-RATED SLEEVES WHEN PENETRATING FIRE-RATED WALLS.
IT IS THE RESPONSIBILITY OF THE DIVISION 27 CONTRACTOR TO INVESTIGATE AND
LOCATE (TONE AND TEST) ALL EXISTING CATEGORY 5 STATION CABLING; IF APPLICABLE.
DIVISION 27 CONTRACTOR TO REPLACE ALL WIRELESS ACCESS POINTS WITH CATEGORY
6A CABLING. PROVIDE AND INSTALL TWO (2) CAT6A CABLES (ONE PUBLIC, ONE HOSPITAL
NETWORK) WITH A 20' LOOP AT STATION END TO EACH DEVICE. IT IS THE
RESPONSIBILITY OF THE DIVISION 27 CONTRACTOR TO INVESTIGATE AND LOCATE ALL
EXISTING WIRELESS ACCESS POINT STATION CABLING. DIVISION 27 CONTRACTOR TO
PROVIDE HEAT MAPPING SHOWING NEW WIRELESS LOCATIONS AND COVERAGE.
DUE TO DIFFERENCES OF AGE AND CONSTRUCTION OF EXISTING BUILDINGS - DIVISION
27 CONTRACTOR TO BE AWARE OF CHALLENGES SUCH AS HORIZONTAL OBSTRUCTIONS
AND CLEAR WORKING SPACE ABOVE CEILINGS. SURFACE MOUNT NON-METALLIC
RACEWAY MAY BE USED ONLY WHERE IT IS IMPOSSIBLE TO FEED NEW CABLING VIA
FISHED WALLS OR OTHER METHODS AND APPROVED BY OI&T DEPARTMENT.
EXISTING STATION LOCATIONS ARE DIAGRAMMATIC IN NATURE AND REPRESENTATIVE
OF FIELD INVESTIGATION AT AN EYE LEVEL ONLY. ALL STATION QUANTITIES TO BE
VERIFIED PRIOR TO AREA BEING REMODELED AND CONFIRMED WITH OI&T PRIOR TO
INSTALLATION.
1" = 300'-0"
PLAN KEY
TELECOM AND SECURITY PLAN -
2ND FLOOR
05.26.2021 SHEET 201 of 421
TR
R
M N
O
RT
H
TO
W
ER
S
ER
VI
N
G
AR
EA
TR
R
M D
0B
S
ER
VI
N
G
AR
EA
G
L
A
11 17
18.6
S
R
Room
1612NURSE STA
Room
ABAN TR
C321
SIGNAL
CC4A
LINEN
C339
HEAD NURSE
C329
HEAD NURSE
C323
Room
ELEC
CC4C
LINEN
C347
CLEAN
C326
DOCTORS RM
C325
MEDS
C328Room
1647CHASE
C329H
EQUIP
C327
Room
STAIR
NO #
OFFICE
C337
STAIR 2
HKC
D313
STAFF LOUNGE
D330A
Room
CLEAN
D301
Room
SOILED
D302
STOR
D330
Room
STAIR
OFFICE
3407Room
OFFICE
Room
OFFICE
OFFICE
LIBRARY
Room
CHEMO IV PREP
3108C
IV PREP
3108B
TECHNICIANS
NO #
Room
Room
STAIR
NO#
Room
PHARMACY
Room
Room
Room
Room
OCCUPATIONAL
HEALTH
Room
ON CALL
ON CALL
Room
ON CALL
ON CALL
LINEN
OFFICE
LOBBY
OFFICE
OFFICE
OFFICE
HALLWAY
OFFICE
OFFICE
OFFICE
Room
Room
Room
ABAN TR
3329A
CONF
SLEEP RM
SLEEP RM
OFFICE
TOILET
3320A
TEL
STAIR
TOILET
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
1 BED
NURSE STATION
BREAK RM
3204D
HKC
TOILET
TOILET
3208B
MEDS
SOILDED
TOILET
TOILET
2 BED
CORRIDOR
NO#
4 BED
3204C CLEAN
STORAGE
3201A
Room
OFFICE
LOUNGE
OFFICE
3126A
Room E300A
VEST
OFFICE
3204OFFICE
3204G
TLT
3204B
TLT
3204E
STAIR
STAIR
ABAN TR
3412A
Room 1795 Room
Room D326A
Room D323B
CLERK
DE26B
Room D330
SHAFT
OR 2
D312
Room
OR 7
D308
EQUIP RM
D323D
REPORT
D323D
EQUIP RM
D311B
EQUIPMENT
D315
STORAGE
D314
SHAFT
CORE
D323
WOMEN'S LOCKER
D325
HKC
D316
Room
CD5B
OR 6
D320
ANTI
CHANGE
D238B
ANESTHEIA
D321
Room
HOLDING AREA
D329A
CLEAN
D324C
PREP
D327
RECOVERY
D324
Room
TOILET
D329B
SAME-DAY SURGURY
D329
TOILET
D338
TOILET
D337Room
D329C
STOR
D336
Room D329D
OR 3
D313
Room
OR 5
D322
OR 4
D314
CORRIDOR
Room
ICU 19
C315
ICU 18
C318
ICU 17
C317
ICU 16
C316
ANTE
C312A
ICU 6
C306
ANTE
C308A
TOILET
Room
TOILET
TRAINING RM
C320
SOILED
C330
ELEC
STAIR
MECH SHAFT
HKC
C331
Room
C335A OFFICE
D249B
Room C335C
LOUNGE
C322
Room
1872 OFFICE
C335
Room
NURSE STA
OFFICE
C334
OFFICE
D304
TOILET
C336
CORRIDOR
OR 1
D311
STOR
STOR
3216A
1 BED
TOILET
3225A
1 BED
1 BED
TOILET
3231A
HKC
3112TOILET
OFFICE
TOILET
CONFERENCE
E301
TOILET
E309
OFFICE/EXAM
E317
OFFICE/EXAM
E316
OFFICE/EXAM
E315
TOILET
E322OFFICE/EXAM
E314
OFFICE/EXAM
E313
OFFICE/EXAM
E312
OFFICE/EXAM
E311
EVS
E305
ELEC
E304
TOILET
E303
BIO-MED
E302
ELECT
E306
BREAK RM
E321
OFFICE/EXAM
E323
PRE-PROCEDURE
WAITING
E310
1 BED
STAIR
1 BED
TOILET
3233A
1 BED
1 BED
TOILET
3223A
1 BED
3 BED
TOILET
3215A
CLEAN
Room
3 BED
3 BED
TOILET
3206A
STOR
STOR
CONFERENCE
Room
HKC
Room
STORAGE
(E) OFFICE
Room
MECH STORAGE
3314 Room
3322A
Room
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
ON CALL
Room
ICU 5
C305
ICU 4
C304
ICU 3
C303
ICU 2
C302
ICU 1
C301
ICU 20
C300
ICU 7
C307
ICU 13
C313
ICU 12 ISOLATION
C312
ICU 11
C311
ICU 10
C310
ICU 9
C309
ICU 8 ISOLATION
C308
ICU 15
C315
MALE LOCKER
D379
RECEIVING
3108G
FAMILY WAITING
E300
Room C324A
NURSE STA
NURSE STA
OMNICELL
3CC5A-1 RESP THERAPY
C337
TELEMENTARY
STATION
NO #
RECEPTION CLERK
NO #
PRE-PROCEDURE
ADMIN
E324
OFFICE
3108E
OFFICE
3108F
ANTEROOM
3108A
VAULT
3108D
TOILET
3140A
OFFICE
Room
CUBICLES
TELE-HEALTH CALL-IN
CUBICLES
TELE-HEALTH CALL-IN
OFFICE
OFFICE
ELEC
D309
ABAN TR
D305B
TR MECH
TRS-300B
ABAN TR
D305D
TR
TRN-300A
TR ELEC
TRS-300C TR ELEC
TRN-300C
TR
TRS-300A
TR MECH
TRN-300B
CORRIDOR
AC301
ELEVATOR LOBBY
C615C
ICU 14
C314
CORRIDOR
CORRIDOR
C319
CORRIDOR
C324
STOR
CORRIDOR
HALL
E307
CORRIDOR
01-TN403
01-TN403
SURGERY
ICU
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR 3329A - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRN-300A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 282'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR D305D - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRN-300A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 282'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR C321 - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-300A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 285'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR D305B - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-300A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 285'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR 3412A - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRN-300A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 220'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-300A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 285'
2 2
TOTAL CABLES 406
TOTAL CABLES 192
TOTAL CABLES 110
TOTAL CABLES 223
TOTAL CABLES 176
TOTAL CABLES 251
BLDG 01
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans
Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET OF
BI
M
Ph oe ni x
EH
R M
/6
-2 0-
BL
D
G
1_ A.
rv t
9/ 6/
:3
6:
P M
01-TN103
TELECOMMUNICATIONS PLAN
3RD FLOORConcourse Federal Group
11755 Wilshire Blvd., Suite 1250 Los Angeles, CA 90025
EHRM INFRASTRUCTURE
UPGRADES 01
PVAHCS - Carl T Hayden Medical Center 650 E Indian School Road Phoenix AZ 85012
644-20-201
10 10 20 30 40 50 60 3/64" = 1'-0"
FEETSCALE
Revisions: Date: 02.05.2021 CCSTEAM
4365 E. PECOS RD. - GILBERT, AZ. 85295
(602) 619-9710 - VOICE
OLYMPUS CONSTRUCTION MANAGEMENT
04.01.2021
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
KEYED NOTES:
EXISTING TR TO BE ABANDONED. EXISTING ENTRANCE FACILITIES AND
COPPER BACKBONE TO REMAIN. EXISTING FLOOR SERVING CABLING TO BE
RE-ROUTED TO NEW TRS-300A
EXISTING TR TO BE ABANDONED. EXISTING ENTRANCE FACILITIES AND
COPPER BACKBONE TO REMAIN. EXISTING FLOOR SERVING CABLING TO BE
RE-ROUTED TO NEW TRN-300A
PROVIDE NEW 12" X 4" BASKET TYPE CABLETRAY IN CORRIDOR FROM NEW TR
ROOM AS SHOWN, CONNECT TO EXISTING. FIELD COORDINATE WITH OTHER
TRADES. CABLETRAY TO BE MOUNTED MINIMUM 6" ABOVE FINISHED CEILING
WITH TWO SIDES OF 12" CLEARANCE.
EXISTING OVERHEAD PATHWAY.
GENERAL NOTES:
DIVISION 27 CONTRACTOR TO COORDINATE ALL CUTOVERS WITH OI&T DEPARTMENT
PRIOR TO DEMOLITION OR INSTALLATION. ALL EXISTING DATA CABLES AND CIRCUITS
MUST REMAIN IN PLACE AND OPERATION UNTIL FINAL CUT-OVER TO ANY NEW OR
REPLACEMENT CABLING.
EXISTING OVERHEAD PATHWAYS (CABLETRAY, CONDUIT, SLEEVING) TO BE USED.
INSTALL FIRE-RATED SLEEVES WHEN PENETRATING FIRE-RATED WALLS.
IT IS THE RESPONSIBILITY OF THE DIVISION 27 CONTRACTOR TO INVESTIGATE AND
LOCATE (TONE AND TEST) ALL EXISTING CATEGORY 5 STATION CABLING; IF APPLICABLE.
DIVISION 27 CONTRACTOR TO REPLACE ALL WIRELESS ACCESS POINTS WITH CATEGORY
6A CABLING. PROVIDE AND INSTALL TWO (2) CAT6A CABLES (ONE PUBLIC, ONE HOSPITAL
NETWORK) WITH A 20' LOOP AT STATION END TO EACH DEVICE. IT IS THE
RESPONSIBILITY OF THE DIVISION 27 CONTRACTOR TO INVESTIGATE AND LOCATE ALL
EXISTING WIRELESS ACCESS POINT STATION CABLING. DIVISION 27 CONTRACTOR TO
PROVIDE HEAT MAPPING SHOWING NEW WIRELESS LOCATIONS AND COVERAGE.
DUE TO DIFFERENCES OF AGE AND CONSTRUCTION OF EXISTING BUILDINGS - DIVISION
27 CONTRACTOR TO BE AWARE OF CHALLENGES SUCH AS HORIZONTAL OBSTRUCTIONS
AND CLEAR WORKING SPACE ABOVE CEILINGS. SURFACE MOUNT NON-METALLIC
RACEWAY MAY BE USED ONLY WHERE IT IS IMPOSSIBLE TO FEED NEW CABLING VIA
FISHED WALLS OR OTHER METHODS AND APPROVED BY OI&T DEPARTMENT.
EXISTING STATION LOCATIONS ARE DIAGRAMMATIC IN NATURE AND REPRESENTATIVE
OF FIELD INVESTIGATION AT AN EYE LEVEL ONLY. ALL STATION QUANTITIES TO BE
VERIFIED PRIOR TO AREA BEING REMODELED AND CONFIRMED WITH OI&T PRIOR TO
INSTALLATION.
1" = 300'-0"
PLAN KEY
TELECOM AND SECURITY PLAN -
3RD FLOOR
05.26.2021 SHEET 202 of 421
TR
R
M N
O
RT
H
TO
W
ER
S
ER
VI
N
G
AR
EA
TR
R
M D
6C
S
ER
VI
N
G
AR
EA
G
L
A
11 17
18.6
S
R
CORRIDOR
STAIR
CLEAN LINEN
D401A
STAIR
OFFICE
D447
STAIR
HKC
4123A
Room
Room 4117A
SHARED OFFICE
OFFICE
4305B
OFFICE
4305A
OFFICE
4315A
OFFICE
4315D
Room
COPIER
CLEAN SUPPLY
HKC
ABAN TR
4317B
OFFICE
4314A
LOCKER
OFFICE
4315B
OFFICE
4315C
OFFICE
4314B
STAIR
Room
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
TLT
Room
OFFICE
OFFICE
4214D
STAIR
LOBBY
ABAN TR
D456
OFFICE
D441
OFFICE
D449
RECEPTION
D458
OFFICE
D453
WAITING ROOM
D455
ELEC
ELEC
CC1ASTAIR
OFFICE
D460 OFFICE
D460A
LAB
D463
ELEVATOR LOBBY
EXAM 2
E420
OFFICE
OFFICE
CONFERENCE
Room
OFFICE
OFFICE
4302 OFFICE
OFFICE
OFFICE
4324C
WATER TREATMENT
4324B
OFFICE
4305C
OFFICE
D444
OFFICE
D442
1 BED
D439
2 BED
D438
2 BED
D434
Room D434A
Room
TOILET
D424A
2 BED
D431
OFFICE
D431A
Room
2 BED
D427
Room D427A
Room D426A
Room D425A
1 BED
D426
1 BED
D425
2 BED
D424
2 BED
D420
TOILET
D422A
1 BED
D422
2 BED
D418
TOILET
D420A
TOILET
D418A
2 BED
D416
OFFICE
D414
TOILET
D416A
COMPUTER
D412
CORRIDOR
STORAGE
D405
OFFICE
D407
OFFICE
D406
TOILET
C402A
TOILET
C403A
OFFICE
D463A
EXAM
D460B
OFFICE
D460C
CONFERENCE
C435
OFFICE
C433
STAFF
D403
SHAFT
EXAM 4
E417
OFFICE
4123E
STAIR
OFFICE
4214B
Room
TREADMILL TESTING
4214G
ECHO LAB
4214A
STORAGE
TOILET
4213A
EXAM
ABAN TR
4215A
OFFICE
TOILET
4217A
OFFICE
TOILET
OFFICE
OFFICE
Room
MECHANICAL
STORAGE
TOILET
OFFICE
OFFICE
OFFICE
EKG
TOILET
4216A
TOILET
4210A
OFFICE
WAITING ROOM
WAITING
Room 4128A
STAIR
TOILET
4214E
Room
Room
ABAN TR
D434B
OFFICE
D419
CLN SUPPLY
D417
MEDS
D437
TUB
D433
STORAGE
D423 OFFICE
D421
Room
DUCT SHAFT
Room xx
ABAN TR
C421A
ELEC
CC4C
MEDS
C421
HKC
4107A
OFFICE
OFFICE
D450
OFFICE
D452
OFFICE
D454
TOILET
D457
Room 4226F
EXAM 3
E419
EXAM 1
E421 P TOILET
E409A
S TOILET
E409B
PAT BAY 1
E416
PAT BAY 2
E415
PAT BAY 3
E414
DOCTOR'S
E411C
STOR
C400
LINEN
D402
TOILET
D466
STAFF
D404
OFFICE
D464
OFFICE
D462
Room
EXAM
4323A
RENAL LAB
4324A
OFFICE
SOILED UTILITY
STOR
4121A
TOILET
4317A
OFFICE
4120A
STORAGE
ELEC
CE1A
MEDS
E408
CLEAN SUPPLY
E407
PAT BAY 4
E413
PAT BAY 5
E412
PAT BAY 6
E411
SOILED WORK RM
E410
CATH LAB
E403
STORAGE
E402
OFFICE
4123B
STOR
4123F
BREAK ROOM
4123D
TOILET
4123C
CONTROL ROOM
E401
ELEC
E404
OFFICE
D448
OFFICE
D446
DINING ROOM
D440
TOILET
D439A
Room D434A
STAFF
NO #
OFFICE
D430
NURSE STATION
D415
OFFICE
D443
OFFICE
D445
OFFICE
D413
BREAK ROOM
D434F
OFFICE
D409 LOCKERS
D465
TOILET
C401A
2 BED
C401
BREAK RM
C417
OFFICE
C434
2 BED
C402
TOILET
C418 OFFICE
C432
REPORT
C419 OFFICE
C428
2 BED
C402K
Room C402L
Room
C402M SPD
C426STOR
C422
2 BED
C414
TOILET
C413A
TOILET
C414A
2 BED
C413
TOILET
C407A
ISOLATION
C407
ISOLATION
C408
ISOLATION
C409
ISOLATION
C410
ISOLATION
C411
HOSPITALIST
C411
TOILET
C411A
TOILET
C410A
TOILET
C412A
TOILET
C416A
TOILET
C415A
2 BED
C415
TOILET
C408A
TOILET
C409A
CHARTING
C424
STOR
C423
NURSE STA
C420
STOR
C427
TOILET
TOILET
TR
TRN-400A
TR ELEC
TRS-400C TR ELEC
TRN-400C
TR
TRS-400A
TR MECH
TRS-400B
TR MECH
TRN-400B
CORRIDOR
AC400
OFFICE
D408
HAC
D410
ELEVATOR LOBBY
D400
STORAGE
D400A
CORRIDOR
CORRIDOR
D228
CORRIDOR
CORRIDOR
2 BED
C403
2 BED
C405
TUB
C425
2 BED
C416
01-TN403
01-TN403
CATH LAB
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR D456 - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-400A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 285'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR D434B - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-400A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 285'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR C421A - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR S-400A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 285'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR 4317B - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRN-400A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 270'CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR 4215A - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRN-400A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 270'
TOTAL CABLES 192
TOTAL CABLES 299
TOTAL CABLES 223
TOTAL CABLES 176
TOTAL CABLES 241
BLDG 01
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans
Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET OF
BI
M
Ph oe ni x
EH
R M
/6
-2 0-
BL
D
G
1_ A.
rv t
9/ 6/
:3
6:
P M
01-TN104
TELECOMMUNICATIONS PLAN
4TH FLOORConcourse Federal Group
11755 Wilshire Blvd., Suite 1250 Los Angeles, CA 90025
EHRM INFRASTRUCTURE
UPGRADES 01
PVAHCS - Carl T Hayden Medical Center 650 E Indian School Road Phoenix AZ 85012
644-20-201
10 10 20 30 40 50 60 3/64" = 1'-0"
FEETSCALE
Revisions: Date: 02.05.2021 CCSTEAM
4365 E. PECOS RD. - GILBERT, AZ. 85295
(602) 619-9710 - VOICE
OLYMPUS CONSTRUCTION MANAGEMENT
04.01.2021
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
KEYED NOTES:
EXISTING TR TO BE ABANDONED. EXISTING ENTRANCE FACILITIES AND
COPPER BACKBONE TO REMAIN. EXISTING FLOOR SERVING CABLING TO BE
RE-ROUTED TO NEW TRS-400A
EXISTING TR TO BE ABANDONED. EXISTING ENTRANCE FACILITIES AND
COPPER BACKBONE TO REMAIN. EXISTING FLOOR SERVING CABLING TO BE
RE-ROUTED TO NEW TRN-400A
PROVIDE NEW 12" X 4" BASKET TYPE CABLETRAY IN CORRIDOR FROM NEW TR
ROOM AS SHOWN, CONNECT TO EXISTING. FIELD COORDINATE WITH OTHER
TRADES. CABLETRAY TO BE MOUNTED MINIMUM 6" ABOVE FINISHED CEILING
WITH TWO SIDES OF 12" CLEARANCE.
EXISTING OVERHEAD PATHWAY.
GENERAL NOTES:
DIVISION 27 CONTRACTOR TO COORDINATE ALL CUTOVERS WITH OI&T DEPARTMENT
PRIOR TO DEMOLITION OR INSTALLATION. ALL EXISTING DATA CABLES AND CIRCUITS
MUST REMAIN IN PLACE AND OPERATION UNTIL FINAL CUT-OVER TO ANY NEW OR
REPLACEMENT CABLING.
EXISTING OVERHEAD PATHWAYS (CABLETRAY, CONDUIT, SLEEVING) TO BE USED.
INSTALL FIRE-RATED SLEEVES WHEN PENETRATING FIRE-RATED WALLS.
IT IS THE RESPONSIBILITY OF THE DIVISION 27 CONTRACTOR TO INVESTIGATE AND
LOCATE (TONE AND TEST) ALL EXISTING CATEGORY 5 STATION CABLING; IF APPLICABLE.
DIVISION 27 CONTRACTOR TO REPLACE ALL WIRELESS ACCESS POINTS WITH CATEGORY
6A CABLING. PROVIDE AND INSTALL TWO (2) CAT6A CABLES (ONE PUBLIC, ONE HOSPITAL
NETWORK) WITH A 20' LOOP AT STATION END TO EACH DEVICE. IT IS THE
RESPONSIBILITY OF THE DIVISION 27 CONTRACTOR TO INVESTIGATE AND LOCATE ALL
EXISTING WIRELESS ACCESS POINT STATION CABLING. DIVISION 27 CONTRACTOR TO
PROVIDE HEAT MAPPING SHOWING NEW WIRELESS LOCATIONS AND COVERAGE.
DUE TO DIFFERENCES OF AGE AND CONSTRUCTION OF EXISTING BUILDINGS - DIVISION
27 CONTRACTOR TO BE AWARE OF CHALLENGES SUCH AS HORIZONTAL OBSTRUCTIONS
AND CLEAR WORKING SPACE ABOVE CEILINGS. SURFACE MOUNT NON-METALLIC
RACEWAY MAY BE USED ONLY WHERE IT IS IMPOSSIBLE TO FEED NEW CABLING VIA
FISHED WALLS OR OTHER METHODS AND APPROVED BY OI&T DEPARTMENT.
EXISTING STATION LOCATIONS ARE DIAGRAMMATIC IN NATURE AND REPRESENTATIVE
OF FIELD INVESTIGATION AT AN EYE LEVEL ONLY. ALL STATION QUANTITIES TO BE
VERIFIED PRIOR TO AREA BEING REMODELED AND CONFIRMED WITH OI&T PRIOR TO
INSTALLATION.
1" = 300'-0"
PLAN KEY
TELECOM AND SECURITY PLAN -
4TH FLOOR
05.26.2021 SHEET 203 of 421
G
L
A
1 7 11 17 18 20 2118.6
S
R
3 BED
C521
STAIR 3
CLEAN
D501
STAIR 2
CLOSET
D539A
OFFICE
D510
DINING ROOM
D530
OFFICE
D540A
OFFICE
C504
GROUP RM
C502
ELEC
ELEC
CD8A
STAIR 1
DAY RM
C541
3 BED
D528
OFFICE
D520
TOILET
D521A
4 BED
D527
PATIENT LAUNDRY
D527B-1
TOILET
D524A
4 BED
D524
OFFICE
D521
CORRIDOR
5CD-3 MED GAS
D506
PASSAGEWAY
C501B
REPORT RM
C505
OFFICE
C529
2 BED
C528
ELEVATOR LOBBY
RECREATION RM
D538
CLOSET
D538A
CLOSET
D538B
OFFICE
D539
LINEN
D535
CONFERENCE
D512
EXAM
D509
OFFICE
D537
OFFICE
D511
OFFICE
D513
TOILET
D515A
1 BED
D515 OFFICE
D513A
SECULSION
D519
TOILET
D517A
REPORT RM
D517
S TOILET
D503
S TOILET
D504
CORRIDOR
CLOSET
C541B
CLOSET
C541A
ELEC
5CD5C
SIGNAL
CD5B
HKC
D518
SHOWER
D525
OFFICE
D520
ABAN TR
DCC4B
SIGNAL
C517B
DISPENSING
C508A
ELEC
C510
SHOWER
C517A
CLEAN
C513
EXAM
C522
SHOWER
C517A-1
TOILET
D523A
4 BED
D523
4 BED
D526
TOILET
D526A
TOILET
D527A
TOILET
D528A
TOILET
D520A
2 BED
D532 TOILET
D534A
2 BED
D534
SOILED
D502
OFFICE
D542
OFFICE
D508
OFFICE
D505
OFFICE
C501
OFFICE
C501A
OFFICE
C503
OFFICE
C506
OFFICE
C527
OFFICE
C526
OFFICE
C523B
TOILET
C526A
TOILET
C523A
VEST
C523 OFFICE
C523C
OFFICE
C519
TOILET
C521A
TOILET
C520ATOILET
C515A
4 BED
C515
3 BED
C516
3 BED
C518
4 BED
C520
TOILET
C518A
TOILET
C516A
LAUNDRY
C514
2 BED
C511
TOILET
C509A
2 BED
C509
SECLUSION RM
C507
TOILET
C505A
NURSE STATION
C508
TOILET
C529A
OFFICE
D507
OFFICE
D514
OFFICE
D533
OFFICE
D536
MED RM
D516A
S TOILET
D531 NURSE STA
D516
OFFICE
C530
OFFICE
C504A
CORRIDOR
5CD-4
CORRIDOR
5CD-5
CORRIDOR
5CD-6
OFFICE
D522
CORRIDOR
5CD-7
CORRIDOR
5CD-1
CORRIDOR
5CC-3
CORRIDOR
5CC-2
OFFICE
C524HKC
C512
CORRIDOR
5CC-6
CORRIDOR
5CC-5
TOILET
C525
ABAN TR
D535A
TR ELEC
TRS-500C
TR MECH
TRS-500B
TR
TRS-500A
ELEVATOR LOBBY
D500
STORAGE
D500A
CORRIDOR
D228
CORRIDOR
C517
CORRIDOR
OFFICE
D529TUB
D525A
SHAFT
D540
PUMP HOUSE 1
01-TN402
MENTAL HEALTH AREA
MENTAL HEALTH AREA
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR D539A - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-500A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 285'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR D535A - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-500A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 285'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR DCC4B - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-500A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 285'
TOTAL CABLES 110
TOTAL CABLES 152
TOTAL CABLES 192
BLDG 01
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans
Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET OF
BI
M
Ph oe ni x
EH
R M
/6
-2 0-
BL
D
G
1_ A.
rv t
9/ 6/
:3
6:
P M
01-TN105
TELECOMMUNICATIONS PLAN
5TH FLOORConcourse Federal Group
11755 Wilshire Blvd., Suite 1250 Los Angeles, CA 90025
EHRM INFRASTRUCTURE
UPGRADES 01
PVAHCS - Carl T Hayden Medical Center 650 E Indian School Road Phoenix AZ 85012
644-20-201
10 10 20 30 40 50 60 3/64" = 1'-0"
FEETSCALE
Revisions: Date: 02.05.2021 CCSTEAM
4365 E. PECOS RD. - GILBERT, AZ. 85295
(602) 619-9710 - VOICE
OLYMPUS CONSTRUCTION MANAGEMENT
04.01.2021
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
KEYED NOTES:
EXISTING TR TO BE ABANDONED. EXISTING ENTRANCE FACILITIES AND
COPPER BACKBONE TO REMAIN. EXISTING FLOOR SERVING CABLING TO BE
RE-ROUTED TO NEW TRS-500A
PROVIDE NEW 12" X 4" BASKET TYPE CABLETRAY IN CORRIDOR FROM NEW TR
ROOM AS SHOWN, CONNECT TO EXISTING. FIELD COORDINATE WITH OTHER
TRADES. CABLETRAY TO BE MOUNTED MINIMUM 6" ABOVE FINISHED CEILING
WITH TWO SIDES OF 12" CLEARANCE.
EXISTING OVERHEAD PATHWAY.
GENERAL NOTES:
DIVISION 27 CONTRACTOR TO COORDINATE ALL CUTOVERS WITH OI&T DEPARTMENT
PRIOR TO DEMOLITION OR INSTALLATION. ALL EXISTING DATA CABLES AND CIRCUITS
MUST REMAIN IN PLACE AND OPERATION UNTIL FINAL CUT-OVER TO ANY NEW OR
REPLACEMENT CABLING.
EXISTING OVERHEAD PATHWAYS (CABLETRAY, CONDUIT, SLEEVING) TO BE USED.
INSTALL FIRE-RATED SLEEVES WHEN PENETRATING FIRE-RATED WALLS.
IT IS THE RESPONSIBILITY OF THE DIVISION 27 CONTRACTOR TO INVESTIGATE AND
LOCATE (TONE AND TEST) ALL EXISTING CATEGORY 5 STATION CABLING; IF APPLICABLE.
DIVISION 27 CONTRACTOR TO REPLACE ALL WIRELESS ACCESS POINTS WITH CATEGORY
6A CABLING. PROVIDE AND INSTALL TWO (2) CAT6A CABLES (ONE PUBLIC, ONE HOSPITAL
NETWORK) WITH A 20' LOOP AT STATION END TO EACH DEVICE. IT IS THE
RESPONSIBILITY OF THE DIVISION 27 CONTRACTOR TO INVESTIGATE AND LOCATE ALL
EXISTING WIRELESS ACCESS POINT STATION CABLING. DIVISION 27 CONTRACTOR TO
PROVIDE HEAT MAPPING SHOWING NEW WIRELESS LOCATIONS AND COVERAGE.
DUE TO DIFFERENCES OF AGE AND CONSTRUCTION OF EXISTING BUILDINGS - DIVISION
27 CONTRACTOR TO BE AWARE OF CHALLENGES SUCH AS HORIZONTAL OBSTRUCTIONS
AND CLEAR WORKING SPACE ABOVE CEILINGS. SURFACE MOUNT NON-METALLIC
RACEWAY MAY BE USED ONLY WHERE IT IS IMPOSSIBLE TO FEED NEW CABLING VIA
FISHED WALLS OR OTHER METHODS AND APPROVED BY OI&T DEPARTMENT.
EXISTING STATION LOCATIONS ARE DIAGRAMMATIC IN NATURE AND REPRESENTATIVE
OF FIELD INVESTIGATION AT AN EYE LEVEL ONLY. ALL STATION QUANTITIES TO BE
VERIFIED PRIOR TO AREA BEING REMODELED AND CONFIRMED WITH OI&T PRIOR TO
INSTALLATION.
1" = 300'-0"
PLAN KEY
TELECOM AND SECURITY PLAN -
05.26.2021 SHEET 204 of 421
G
L
A
11 17
18.6
S
R
STORAGE FILES
D639
CLOSET
CLEANING SCOPE
D621B
SPECIAL PROCEDURE
D622
OFFICE
D626B
OFFICE
D626C
OFFICE
D626D
OFFICE
D626E
OFFICE
D626A
LOBBY AREA
D626
OFFICE
D626F
OFFICE
D626G
OFFICE
D626H
OFFICE
D623
OFFICE
D616
VIEWING
D614 NURSE STA
D612A
RECOVERY RM
D612
STOR
D627B
ABAN TR
D627A
OFFICE PROVIDER
D627
TOILET
D612D
TOILET
D612C
CLEAN
D607A
CHECKOUT
C6D-8A
ADMIN
C6D-8
O2/CPAP OFFICE
D604
REPORT RM
D600
ELEC
D642A
PATIENT RESTRM
D601
ABG LAB
D644
PATIENT RESTRM
D602
CONFERENCE RM
D641
ADMIN
C626
OFFICE
C626A
OFFICE
C626B
OFFICE
C626C
RESPITORY THERAPY
C624
OFFICE
C623A
OFFICE
C623B
RECEPTION AREA
C623
OFFICE
C621
OFFICE
C620
AUTOMATION CENTER
C620A
STOR
C619A
TOILET
C616A
DIRECTOR'S OFFICE
C616AD OFFICE
C615A
AD/PCS OFFICE
C615
OFFICE
C614
TOILET
OFFICE
C608A
STOR
C607
ELEC
C609
SLEEP LAB PATIENT
RM
C622C
CONTROL RM
C622
PATIENT RM SLEEP
LAB
C622A
TOILET
C622A1
TOILET
PREP RM SLEEP LAB
C604
CONF/BREAK RM
C605
OFFICE
C606
OFFICE
C606A
SLEEP PULM OFFICE
C625
OFFICE
C627
ED RM CPAP
C603
OFFICE
C628
HKC
C629
STORAGE
C600
PASSAGEWAY
C600
BRONCH LAB
D603
OFFICE
D605
LAB 2
D606
LAB 3
D608
OFFICE STOR RM
D610
GI PROCEDURE RM 1
D611
GI PROCEDURE RM 2
D613SCOPE CLEANING
D613B
TOILET
D613A
TOILET
D615A
GI PROCEDURE RM 3
D615
GI PROCEDURE RM 4
D617
SCOPE CLEANING
D617B
TOILET
D617A
GI PROCEDURE RM 5
D618
CLEAN
D619
TOILET
D618A
TOILET
D621A
GI PROCEDURE RM 6
D621
CONFERENCE
D636
TOILET
D634
TOILET
D635
MOTILITY LAB
D637
DICTATION
D637A
OFFICE
D638A
CONF RM
D638
RECEPTION &
ADMISSIONS
C6D-10
WAITING
C6D-11
EXAM RM
C603B
OFFICE
C601
Room C603D
ABAN TR
C612
SIGNAL
C611
RECEPTION
C610
TOILET
C622B
SOILDED
D620
ELEC
D624
ELEC
D625
TOILET
D622A
ELEC
D642
TR ELEC
TRS-600C
TR
TRS-600A
TR MECH
TRS-600B
ELEVATOR LOBBY
C615B
ELEVATOR LOBBY
D600
STORAGE
D600A
SHAFT
D540
STAIR 3
STAIR 2
SOILED
D607
HKC
D609
SHAFT
STAIR
SHAFT
TLT
C622D
TLT
C622E
01-TN402
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-600A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 285'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR D627A - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-600A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 285'
CATEGORY 5E PATCH PORTS
CATEGORY 6 PATCH PORTS
CATEGORY 5 PATCH PORTS
OPEN (NON TERMINATED)
EXISTING TR C612 - RELOCATE
1 ALL DATA HORIZONTAL STATION CABLING TO BE
NEW CATEGORY 6A AND TERMINATED WITHIN NEW
TR TRS-600A
AVERAGE DISTANCE IS FROM NEW TR
AVERAGE DISTANCE/CABLE 285'
3 3
TOTAL CABLES 298
TOTAL CABLES 192
TOTAL CABLES 331
BLDG 01
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans
Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET OF
BI
M
Ph oe ni x
EH
R M
/6
-2 0-
BL
D
G
1_ A.
rv t
9/ 6/
:3
6:
P M
01-TN106
TELECOMMUNICATIONS PLAN
6TH FLOORConcourse Federal Group
11755 Wilshire Blvd., Suite 1250 Los Angeles, CA 90025
EHRM INFRASTRUCTURE
UPGRADES 01
PVAHCS - Carl T Hayden Medical Center 650 E Indian School Road Phoenix AZ 85012
644-20-201
10 10 20 30 40 50 60 3/64" = 1'-0"
FEETSCALE
Revisions: Date: 02.05.2021 CCSTEAM
4365 E. PECOS RD. - GILBERT, AZ. 85295
(602) 619-9710 - VOICE
OLYMPUS CONSTRUCTION MANAGEMENT
04.01.2021
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
KEYED NOTES:
EXISTING TR TO BE ABANDONED. EXISTING ENTRANCE FACILITIES AND
COPPER BACKBONE TO REMAIN. EXISTING FLOOR SERVING CABLING TO BE
RE-ROUTED TO NEW TRS-600A
PROVIDE NEW 12" X 4" BASKET TYPE CABLETRAY IN CORRIDOR FROM NEW TR
ROOM AS SHOWN, CONNECT TO EXISTING. FIELD COORDINATE WITH OTHER
TRADES. CABLETRAY TO BE MOUNTED MINIMUM 6" ABOVE FINISHED CEILING
WITH TWO SIDES OF 12" CLEARANCE.
EXISTING OVERHEAD PATHWAY.
GENERAL NOTES:
DIVISION 27 CONTRACTOR TO COORDINATE ALL CUTOVERS WITH OI&T DEPARTMENT
PRIOR TO DEMOLITION OR INSTALLATION. ALL EXISTING DATA CABLES AND CIRCUITS
MUST REMAIN IN…