Attachment D - Statement_of_Special_Inspections.pdf

PDF 151 KB Posted

Attached to
P602U MSRON TWO Combatant Craft Maintenance Facility
Solicitation number
N4008524R2592
Issued by

About this file

This document is a Statement of Special Inspections for a project to construct a Combatant Craft Maintenance Facility at Joint Expeditionary Base Little Creek - Fort Story in Virginia Beach, Virginia. The project has a seismic design category of B and a design wind speed of 115 mph. Critical lateral and vertical force resisting systems that require special inspection include steel rigid frames, conventional bracing, portal frames, and horizontal bracing elements. The Special Inspector of Record is John Doe, P.E. of ABC Structural Consulting, who can be reached at the provided phone numbers.

View the file

Other files

File Type Posted
0005_Attachment G-REV3 - VA20240167 21JUN24.pdf PDF
Amendment_0005.pdf PDF
Amendment_004.pdf PDF
003_Attachment R - DON_REA.pdf PDF
Amendment_003.pdf PDF
003_Attachment M - Price Proposal Form_rev1.pdf PDF
Amendment_002.pdf PDF
002_Attachment L - PPI Responses_29FEB24.pdf PDF
001_Attachment Q - S-505.pdf PDF
Amendment_001.pdf PDF
001_Attachment L - PPI_Responses_27FEB24.pdf PDF
001_Attachment O - SiteVisitLog_27Feb24.pdf PDF
001_Attachment P - S-101.pdf PDF
001_Attachment G - VA20240167_23FEB24.pdf PDF
Attachment I - Site Location and Parking.pdf PDF
Attachment C - Schedule of Special Inspections.pdf PDF
Attachment K - ONE DAY PASS FORM.xls XLS spreadsheet
Attachment N - Solicitation Provisions.pdf PDF
Attachment L - Pre-Proposal Inquiry Form.xlsx XLSX spreadsheet
Attachment M - Price Proposal Form.pdf PDF
Attachment J - SECNAV 5512.pdf PDF
Attachment E - Utility Permit - P602.pdf PDF
Attachment G - VA20240167_05JAN2024.pdf PDF
24R2592 General Requirements.pdf PDF
Attachment A - 1717512 SPEC COMPLETE.pdf PDF
Attachment H - CJA.pdf PDF
Attachment F - REGISTER.pdf PDF
Attachment B - 1717512 DRAWINGS.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project:

Location:

Project #:

Date:

B

II

19'‐6" at eave

No

See PEMB note 3 on Sheet S‐001.

See PEMB note 3 on Sheet S‐001.

Horizontal LFRS Elements Notes

Conventional X‐bracing

Portal Frame

Project Risk Category:

Project Design Wind Speed (Vasd in mph):

Number of Stories:

Structure Height Above Grade (ft):

See Plan

Following is a listing of critical main wind/seismic force resisting systems for this structure. Carefully inspect these elements as part of the roles and responsiblities of the Special Inspector (reference the Schedule of Special Inspections for inspection checklists).

Lateral Force Resisting System (LFRS) 2015 IBC 1704.3.2 and 1704.3.3

Vertical LFRS Elements Notes

Steel Rigid Frames

Professional Registration Number:

Consulting Firm Name (if any):

SIOR Office AND Mobile Phone Number:

IS NOT

Group H Occupancies (2015 IBC, Section 415) required (per UFGS 01 45 35, Section 1.3.8)

John Doe P.E.

C222222

ABC Structural Consulting

1234567895 (Mobile), 123456789 (Office)

Hazardous Occupancy or attached to such?

Special Inspector of Record (SIOR) A Special Inspector of Record (SIOR)

SIOR Name (Registered Professional):

P602 ‐ Building 1261

Virginia Beach, VA

1334032

1/14/2019

Project Seismic Design Category:

STATEMENT OF SPECIAL INSPECTIONS

File details come from the government source that posted it. Updated .