This is an architectural drawing attachment for a roof replacement project at the South Central Regional Wastewater Treatment Facility in Brevard County, Florida, located at 10001 North Wickham Road, Melbourne. The drawings document the design of a complete roof replacement system, including modifications to the roofing structure, wall flashing details, lightning protection systems, and ventilation features. The project scope encompasses tearoff of the existing modified bitumen roof to the structural concrete deck, installation of a new 1/8" tapered system, application of a 2-ply white Soprema brand modified bitumen rolled roofing system, installation of new wall flashing with termination bars and stainless-steel counter flashing, removal and replacement of the existing lightning protection system, and installation of an exterior ladder. The project must be completed within 45 calendar days from the Notice to Proceed, including a 14-day permitting period, with an additional 30 calendar days allowed for final completion. A non-mandatory pre-bid walkthrough was scheduled for March 4, 2026 at 10:00 AM, the question deadline was March 11, 2026 at 5:00 PM, and sealed bids were due by March 25, 2026 at 10:00 AM.
Qualified contractors must hold a current State of Florida or Brevard County contractor license as a Roofing Contractor, General Contractor, or Building Contractor, and must provide minimum five references from similar projects completed within the past three years. All pricing must remain firm for 90 days from bid opening and include FOB Destination with all shipping, handling, packing, delivery charges, and fuel surcharges. For bids exceeding $200,000, a Public Construction Bond equal to 100% of the contract price is required within five days of award notice. The contractor must provide a 20-year Manufacturer's No Dollar Limit Total System Roofing Warranty and one-year contractor warranty on labor. Required insurance includes General Liability Insurance with $1,000,000 combined single limit per occurrence, Auto Liability Insurance with $1,000,000 combined single limit per occurrence, Workers' Compensation insurance as required by Florida Statute, and Builders Risk Insurance or Installation Floater coverage equal to the project value. Soprema is identified as the Basis of Design, though alternative manufacturers may be substituted with pre-bid approval. Brevard County is exempt from federal excise taxes and all sales taxes, and reserves the right to reject any and all bids or award the contract to individual items, groups of items, all or none, or a combination thereof.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid_Tabulation_-_Names_Only.pdf | ||
| Addendum_2.pdf | ||
| Attachment_D_-_REVISED_Drawings.pdf | ||
| Addendum_1.pdf | ||
| Inv_&_Specs_B22614.pdf | ||
| Attachment_B_-_Drawings.pdf | ||
| Attachment_C_-_Substitution_Request_Form.pdf | ||
| Attachment_A_-_General_Conditions.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1.
.2
Sh ad
L T ra yl or D ig ita lly s ig ne d by
S ha d L
Tr ay lo r
D N
: C N
=S ha d L
Tr ay lo r, dn Q ua lif ie r=
A0
D
9F E2
E5 7A
O
=F lo rid a, C =U
S R ea so n:
I am th e au th or o f t hi s do cu m en t D at e:
6.
.1
:2
6:
-0 5'
.2
.2
.2
1' - 4"1' - 4"1' - 4"
RI
TC
H
GR
ISS
OM
ME
MO
RI
AL
WE
TL
AN
DS
CO
UN
TY
O
WN
ED
G E N
E R
A L N
O T E S
10001 N. WICKHAM ROAD, MELBOURNE, FLORIDA
REV#DATEREVISION
DRAWING TITLE
-0
7-
PR
O J.
N O
SC
AL
E:
D
AT
E:
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D R
AW
IN
G N
O
.:WASTE WATER TREATMENT CENTER
BREVARD COUNTY SOUTH CENTRAL WWTP
EN
G
IN
EE
R O
F
RE
C O
RD
PE
D
A V
ID
E
. A
LL
EY
, P
E
PE
WWW.CEGENGINEERING.COM
MELBOURNE, FL 32935
2651 EAU GALLIE BLVD, SUITE A
TEL. 321.253.1221
C.O.A. #0008097 Consulting Engineers
CONSTRUCTION
ENGINEERING
GROUP
P L A N
N O
T E S
E-
D
EA
M
AJ
M
AJ
AS
N
O
TE
D
LIGHTNING PROTECTION PLAN AND DETAILS
G E N
E R
A L R
E Q
U
IR
E M
E N
T S
E L E C
T R
IC
A L N
O T E S
S U
B M
IT
T A L S
A B
B R
E V
IA
T
IO
N S
A L T E R
A T
IO
N N
O T E S
P R
O J E C
T C
O M
P L E T
IO
N R
E Q
U
IR
E M
E N
T S
A
IR
T E R
M
IN
A L D
E T A
IL
A
T Y P
IC
A L B
O N
D
IN
G S
P L
IC
IN
G
D E T A
IL
S E X H
F A N
V
E N
T D
E T A
IL
B
L
IG
H T N
IN
G
P R
O T E C
T
IO
N P
L A N
N
K E Y P
L A N
N
BI
D
SE