This is an asbestos survey report for the Department of Veterans Affairs Orlando VA Medical Center Lake Nona Campus in Orlando, Florida. The report details asbestos sampling conducted at multiple buildings on the campus, including the hospital, clinic, community living center, central energy plant, and others. Suspect materials were identified in each building and samples were collected and analyzed by laboratory. The report provides findings on asbestos-containing materials identified through sampling, including location, quantity, and condition. It also provides conclusions and recommendations.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS SURVEY REPORT
Buildings: 1, 2, 5, 6, 7, 8, 9, 10, 11, 13, Interstitial of 1 & 2
Orlando VA Medical Center Lake Nona Campus Orlando, FL 32827
MECX Project Number: 1244.020C.02
Prepared for:
Department of Veterans Affairs
Orlando VA Medical Center 13800 Veterans Way
Order No. VA248-17-P-2230
Matthew Haak
TDSHS 10-5791
13 September 2017
ORLANDO VAMC, LAKE NONA CAMPUS
13 SEPTEMBER 2017
C:\Users\mhaak\Desktop\Orlando VA ACM Survey\Final Report\Orlando VA Medical Center ACM Report.docx
TABLE OF CONTENTS
Section Page
1.0 INTRODUCTION
1.1 REGULATORY REQUIREMENTS
1.2 SURVEY BUILDINGS
2.0 SCOPE OF WORK
2.1 METHODOLOGY
2.2 SAMPLING STRATEGY
Surfacing Materials Thermal Systems Insulation Miscellaneous Materials Non-Suspect ACM Condition Classification
2.3 SURVEY DESCRIPTION
3.0 FINDINGS PER BUILDING
3.1 BUILDING 1, CLINIC
Building 1 - Suspect Asbestos-Containing Materials Building 1 - Samples Reported as Asbestos-Containing
3.2 BUILDINGS 2 AND 5, HOSPITAL AND WAREHOUSE
Buildings 2 and 5 - Suspect Asbestos-Containing Materials Building 2 and 5 - Samples Reported as Asbestos-Containing
3.3 BUILDING 6, MAIN ENTRY
Building 6 - Suspect Asbestos-Containing Materials Building 6, Samples Reported as Asbestos-Containing
3.4 BUILDING 7, CENTRAL ENERGY PLANT
Building 7- Suspect Asbestos-Containing Materials Building 7 - Samples Reported as Asbestos-Containing
3.5 BUILDING 8, SERVICE ENTRY
Building 8 - Suspect Asbestos-Containing Materials Building 8 - Samples Reported as Asbestos-Containing
3.6 BUILDING 9, DOMICILE
Building 9 - Suspect Asbestos-Containing Materials Building 9 - Samples Reported as Asbestos-Containing
3.7 BUILDING 10, CHAPEL
Building 10 - Suspect Asbestos-Containing Materials
3.8 BUILDING 11, COMMUNITY LIVING CENTER
Building 11 - Suspect Asbestos-Containing Materials Building 11 - Samples Reported as Asbestos-Containing
3.9 BUILDING 13, SIM LEARNING
Building 13 - Suspect Asbestos-Containing Materials Building 13 - Samples Reported as Asbestos-Containing
4.0 CONCLUSIONS AND RECOMMENDATIONS
5.0 LIMITATIONS
APPENDICES
A – Asbestos Summary Table B – Laboratory Results C – MECX’s Project Team Certifications D – Photo Log
ACRONYMS
A Asbestos- Containing Building Materials (ACBM) · 3 asbestos-containing material (RACM) · 3 asbestos-containing materials (ACMs) · 1
D Department of Veterans Affairs (VA) · 1
E Environmental Protection Agency (EPA) · 1 EPA Asbestos Model Accreditation Plan (MAP) · 1
H heating, ventilation and air conditioning (HVAC) · 2 homogeneous area (HA) · 4 homogeneous areas (HA) · 5
L Loflin Environmental Services, Inc. (Loflin) · 3
N National Emissions Standards for Hazardous Air Pollutants (NESHAP) · 1 National Institute of Standards and Technology (NIST) · 3 National Voluntary Laboratory Accreditation Program (NVLAP) · 3
O Occupational Safety and Health Administration (OSHA) · 1
P polarized light microscopy (PLM) · 3
T Texas Department of State Health Services (TDSHS) · 1 the EPA Asbestos Hazard Emergency Response Act (AHERA) · 1 thermal system insulation (TSI) · 2
U United States (U.S.) · 1
V VA Medical Center (VAMC) · 1
1.0 INTRODUCTION
MECX, Inc. (MECX) performed a survey for asbestos-containing materials (ACMs) at ten buildings within the Department of Veterans Affairs (VA), Orlando VA Medical Center (VAMC), Lake Nona Campus located at 13800 Veterans Way, Orlando, FL 32827 (Site).
1.1 REGULATORY REQUIREMENTS
MECX performed the survey in order to meet requirements that are compliant with the United States (U.S.)
Environmental Protection Agency (EPA) Asbestos Hazard Emergency Response Act (AHERA) regulations (40 CFR 763), National Emissions Standards for Hazardous Air Pollutants (NESHAP) regulations (40 CFR 61, Subpart M), and the Occupational Safety and Health Administration (OSHA) Asbestos Standards (29 CFR
1910.1001 and 29 CFR 1926.1101).
MECX licensed asbestos consultants Mr. Matthew Haak (TDSHS License 10-5791) and Mr. James Murray (TDSHS License 10-5776), are Texas Department of State Health Services (TDSHS) licensed Asbestos Consultants. TDSHS licensing and training meet the U.S. EPA Asbestos Model Accreditation Plan (MAP) requirements. Training for asbestos professionals is required under the EPA Asbestos MAP which EPA issued under the Asbestos Hazard Emergency Response Act of 1986 (AHERA). The MAP requires the use of trained and accredited asbestos professionals when conducting asbestos inspections or designing or conducting response actions at schools and public and commercial buildings. It provides guidance to states on the minimum training requirements for accrediting asbestos professionals. State training programs must be at least as stringent as the MAP. The MAP established five required training disciplines:
• Worker,
• Contractor/supervisor,
• Inspector,
• Management planner, and
• Project designer
As licensed Asbestos Consultants, MECX’s representatives are accredited to perform the functions of the five disciplines identified above.
MECX completed the survey between the dates of July 17, 2017 – July 19,2017.
1.2 SURVEY BUILDINGS
The following buildings as specified by representatives of the Orlando VAMC were included in this survey:
Building No. Building Use Year Built
Number of Floors
Approximate Square Feet (sf)
1 Clinic 2015 5 527,916 2 Hospital 2015 5 487,871 5 Warehouse 2015 1 56,081 6 Main Entry 2015 1 894
7 CPE 2015 1 41,900
8 Service Entry 2015 1 304
Building No. Building Use Year Built
Number of Floors
Approximate Square Feet (sf)
9 Domicile 2015 4 41,154 10 Chapel 2015 1 2,851
11 CLC 2015 1 117,426
13 Sim Learn 2015 1 45,000
Buildings 1 & 2 Interstitial Space 2015 1 880,000
As directed by the OVAMC, the building roofs and mechanical systems ( i.e., include heating, ventilation and air conditioning (HVAC) duct seam, patching & penetration tar and thermal system insulation (TSI)) on the roof were excluded from the survey. Therefore, MECX did not sample the roofing materials or other materials on the roofs and these materials must be assumed to be asbestos containing until such time they have been tested and shown otherwise.
2.0 SCOPE OF WORK
The objective of this survey, as defined by the OVAMC, was to collect representative samples of suspect friable and non-friable ACMs located in the interior and exterior building spaces, excluding roofs. In addition to collection samples for asbestos analyses, MECX also assessed the condition and quantity of the suspect materials.
2.1 METHODOLOGY
The survey consisted of inspections of reasonably accessible building components to identify suspect ACM.
MECX’s collected samples of suspect ACM in accordance with the U.S. EPA Model Accreditation Plan specified in the AHERA.
MECX placed samples in polyethylene bags with unique identification numbers and then transported the samples under chain-of-custody to Loflin Environmental Services, Inc. (Loflin), in Houston, Texas. Loflin is a licensed asbestos laboratory and a participating member in the National Institute of Standards and Technology (NIST) administered by the National Voluntary Laboratory Accreditation Program (NVLAP). Loflin analyzed bulk samples for asbestos content using polarized light microscopy (PLM), in accordance with U.S.
EPA Analytical Method EPA/600/R-93/116.
The U.S. EPA defines an ACM as material that contains greater than one percent asbestos by PLM analysis (NESHAP 40 CFR Part 61, Subpart M). When the bulk samples contained more than one layer, the laboratory analyzed each layer of the sample.
Suspect samples containing less than or equal to 1% asbestos are not considered ACM by regulatory definition. If lab analysis found that samples were asbestos-containing, then the corresponding material has to potential to be considered a regulated asbestos-containing material (RACM), according the EPA’s NESHAP regulation for renovations and demolitions (reference 40 CFR Part 61).
MECX classified suspect ACMs as either friable or non-friable. A summary of these two classifications is presented below.
• Friable ACMs contain more than 1% asbestos and, when dry, can be crumbled, pulverized or reduced to powder by hand pressure. Friable ACMs are considered RACM and, therefore, subject to U.S. EPA regulations.
• Non-friable ACMs contain more than 1% asbestos and cannot be crushed with hand pressure. Non-friable ACMs are categorized as either Category I or Category II materials.
o Category I - non-friable asbestos-containing packings, gaskets, resilient floor covering, and/or asphalt roofing products.
o Category II - non-friable ACMs that are not Category I.
2.2 SAMPLING STRATEGY
MECX employed the sampling strategy summarized below.
Surfacing Materials MECX collected bulk samples of surfacing materials in a randomly distributed manner. The samples were representative of each homogeneous area (HA). For suspect ACM, MECX collected the following quantity of samples per HA:
• HA ≤ 1, 000 sf: at least three bulk samples
• 1,000 sf ≤ HA ≤ 5,000 sf: at least five bulk samples
• HA > 5,000 sf: at least seven bulk samples.
Thermal Systems Insulation MECX collected at least three bulk samples of thermal systems insulation in a randomly distributed manner.
The samples were representative of each HA. For suspect ACM, MECX collected the following quantity of samples per HA:
• Patched thermal system insulation: at least one bulk sample ≤ 6 linear feet or sf
• Insulated mechanical systems (i.e., cementitious material on joints and valves): at least 3 bulk samples
Miscellaneous Materials MECX collected at least three representative bulk samples of each miscellaneous material (i.e., ceiling tile, floor tile, floor tile mastic, etc.) in a manner sufficient to determine if a material was ACM.
Non-Suspect ACM MECX did not collect samples from HA where it was documented that a material was not ACM.
Condition Classification MECX classified ACM as food, fair or poor condition, as described below.
• Good - material which is intact and absent noticeable damage
• Fair - material with small/minor amounts of localized damage (generally less than 10% of the area)
• Poor - material with a large amount of damage (generally greater than 10% of the surface area).
2.3 SURVEY DESCRIPTION
MECX collected approximately 450 representative bulk samples of accessible interior suspect ACMs. Suspect ACMs may exist in inaccessible or hidden areas of the structure that were not observed or inspected during this investigation.
MECX also performed a limited survey of building exteriors, excluding the roofs. The estimated quantities of ACM made by MECX should be verified prior to removal, if any.
3.0 FINDINGS PER BUILDING
3.1 BUILDING 1, CLINIC
Building 1 - Suspect Asbestos-Containing Materials
MECX identified the following homogeneous areas (HA) within Building 1 and collected bulk samples of these materials for asbestos content.
1. HVAC Duct Insulation Sealant White
2. Chilled Water Insulation Sealant
3. Gray Metal HVAC Duct Seam Sealant
4. Ceiling Tile 2'x2' Beveled Edge
5. HVAC Foil Duct Insulation Sealant
6. Fire Stop Red
7. Pink Fire Sealant
8. Vinyl Floor Tile 18"x18"Beige/Green
9. Vinyl Floor Tile 18"x18"Bamboo
10. Hot Water Insulation Sealant
11. Joint Compound
12. Penetration Packing Gray
13. Roof Drain Insulation Sealant
14. Spray Applied Fire Proofing
15. Vinyl Floor Wood Pattern
16. Wall Texture
17. Cove Base
Building 1 - Samples Reported as Asbestos-Containing
ACM was not reported in the samples collected from Building 1. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the building in areas such as above ceilings and in wall cavities.
3.2 BUILDINGS 2 AND 5, HOSPITAL AND WAREHOUSE
Buildings 2 and 5 - Suspect Asbestos-Containing Materials
MECX identified the following HA within Buildings 2 and 5 and collected bulk samples of these materials for asbestos content.
1. Chilled Water Insulation Sealant
2. Ceiling Tile, 2'x2'
3. HVAC Duct Insulation Sealant
4. Foil HVAC Insulated Duct Sealant
5. Red Fire Stop
6. Purple Vinyl, 24"x24"
7. Beige Vinyl, 24"x24"
8. Gray HVAC Duct Seam Sealant
9. Hot Water Insulation Sealant
10. Joint Compound
11. Penetration Packing Gray
12. Roof Drain Insulation Sealant
13. Spray Applied Beige Fire Proofing
14. Steam Insulation Sealant
15. Sheet Vinyl Flooring, Blue
16. Vinyl Flooring Wood Pattern
17. Water Proofing Sealant Pink
18. Vinyl Cove Base Mastic
Building 2 and 5 - Samples Reported as Asbestos-Containing
ACM was not reported in the samples collected from Buildings 2 and 5. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the building in areas such as above ceilings and in wall cavities.
3.3 BUILDING 6, MAIN ENTRY
Building 6 - Suspect Asbestos-Containing Materials
MECX identified the following HA within Building 6 and collected bulk samples of these materials for asbestos content.
1. Joint Compound
2. Wall Texture
Building 6, Samples Reported as Asbestos-Containing
ACM was not reported in the samples collected from Building 6. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the building in areas
3.4 BUILDING 7, CENTRAL ENERGY PLANT
Building 7- Suspect Asbestos-Containing Materials
MECX identified the following HA within Building 7 and collected bulk samples of these materials for asbestos content.
1. 18"x18" Pale Orange Vinyl Floor Tile
2. Chilled Water Insulation Sealant
3. Ceiling Tile
4. Duct Insulation Sealant
5. White
6. Fire Stop
7. Gray HVAC Duct Mastic
8. Heating Water Insulation
9. Joint Compound
Building 7 - Samples Reported as Asbestos-Containing
ACM was not reported in the samples collected from Building 7. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the building in areas
3.5 BUILDING 8, SERVICE ENTRY
Building 8 - Suspect Asbestos-Containing Materials
MECX identified the following HA within Building 8 and collected bulk samples of these materials for asbestos content.
1. Joint Compound
2. Metal HVAC Duct Seam Sealant
3. Roof Drain
Building 8 - Samples Reported as Asbestos-Containing ACM was not reported in the samples collected from Building 8. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the building in areas
3.6 BUILDING 9, DOMICILE
Building 9 - Suspect Asbestos-Containing Materials
MECX identified the following HA within Building 9 and collected bulk samples of these materials for asbestos content.
1. Chilled Water Line Insulation Sealant
2. Ceiling Tile
3. Domestic Cold Water Insulation Sealant
4. Domestic Hot Water Insulation Sealant
5. Duct Insulation Sealant
6. Foil HVAC Duct Insulation Sealant
7. Red Fire Stop
8. Floor Tile Beige Vinyl 18" Striated
9. Floor Tile
10. Metal HVAC Duct Sealant
11. Hot Water Insulation Sealant
12. Joint Compound
13. Penetration Packing Pink
14. Steam Line Insulation Sealant
15. Blue Sheet Vinyl
16. Vinyl Flooring Wood Patterns
17. Wall Texture
Building 9 - Samples Reported as Asbestos-Containing
ACM was not reported in the samples collected from Building 9. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the building in areas
3.7 BUILDING 10, CHAPEL
Building 10 - Suspect Asbestos-Containing Materials
MECX identified the following HA within Building 10 and collected bulk samples of these materials for asbestos content.
1. Joint Compound
2. Foiled HVAC Duct Insulation Sealant
3. Vinyl Flooring Wood Pattern
4. Ceiling Tile
3.7.2 Building 10 - Samples Reported as Asbestos-Containing
ACM was not reported in the samples collected from Building 10. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the
3.8 BUILDING 11, COMMUNITY LIVING CENTER
Building 11 - Suspect Asbestos-Containing Materials MECX identified the following HA within Building 11 and collected bulk samples of these materials for asbestos content.
1. Vinyl Flooring Wood Pattern
2. Steam Line Insulation Sealant
3. Duct Insulation Sealant
4. Chilled Water Insulation Sealant
5. Hot Water Insulation Sealant
6. Ceiling Tile
7. Wall Plaster Finish
8. Floor Tile Beige Gray
9. Wall Plaster
10. Joint Compound
11. Foil Duct Insulation Sealant
Building 11 - Samples Reported as Asbestos-Containing ACM was not reported in the samples collected from Building 11. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the
3.9 BUILDING 13, SIM LEARNING
Building 13 - Suspect Asbestos-Containing Materials
MECX identified the following HA within Building 13 and collected bulk samples of these materials for asbestos content.
1. Yellow Carpet Mastic
2. Ceiling Tile 2'x2' Smooth No Bevel
3. Duct Insulation Sealant
4. Beige HVAC Duct Seam Sealant
5. Expansion Tank Insulation Sealant
6. Foil HVAC Duct Insulation
7. Gray HVAC Duct Sealant
8. Hot Water Insulation Sealant
9. Joint Compound
10. Spray Applied Fire Proofing
11. Steam Line Insulation Sealant
12. Gray Mottled Sheet Vinyl Flooring
13. Vinyl Floor Wood Pattern
Building 13 - Samples Reported as Asbestos-Containing
ACM was not reported in the samples collected from Building 13. Although this was a comprehensive asbestos survey do to the inaccessibility of some areas hidden suspect materials may exist within the
4.0 CONCLUSIONS AND RECOMMENDATIONS
MECX did not identify ACM during this survey.
This survey reports presents findings of observable and readily accessible materials assessed/sampled. This report does not guarantee that additional ACM is not present (i.e., concealed spaces).
5.0 LIMITATIONS
MECX warrants that the findings contained herein have been prepared with the level of skill exercised by experienced and knowledgeable environmental consultants who are appropriately licensed or otherwise trained to perform assessments pursuant to the scope of work required on this project.
The work that was performed during this investigation was done at the request of the VA and was non-destructive.
Materials may exist in inaccessible or hidden areas of the facility that were not observed or inspected during this investigation. Hidden materials may include, but are not limited to: TSI covered with metal jacketing, gasket material at pipe connections between flanges, vent pipe or duct insulation within wall cavities, vinyl floor tile or sheet flooring beneath sub-floors or overlays, spray-on acoustic texture hidden by door jams or covered with drywall.
The analytical results pertain to only the samples analyzed and may not reflect the actual composition of the entire homogeneous area. MECX assumes no responsibility for any subsequent use or interpretations of these analytical results. Prior to the removal of any asbestos containing materials, if any, a licensed abatement contractor should verify the quantities if removal is planned.
This report must not be used to claim product endorsement by NVLAP or any other state or federal government agency.
The quantification of the asbestos-containing materials are estimates made at the time of sampling. The quantities are estimates only and should be verified by the contractors bidding the project to determine exact square footage’s and the accessibility of the specific materials.
The opinions and conclusions presented here are based on field investigation, and observations made in the field, and are consistent with practices and actions of consulting professionals in the asbestos and industrial hygiene field.
APPENDIX A
Asbestos Summary Table
Building No.
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
HOSP SAFP SAFP‐01 5 Surfacing Good Spray Applied Beige Fire Proofing Structural Supports 5th Level Mechanical Room NA NA
HOSP GDM GDM‐01 5 TSI Good Gray HVAC Duct Seam Sealant Metal HVAC Ducts 5th Level Mechanical Room NA NA
HOSP HWS HWS‐01 5 TSI Good Hot Water Insulation Sealant Hot Water Systems 5th Level Mechanical Room
Air Handler Unit H22
NA NA
HOSP CHWS CHWS‐01 5 TSI Good Chilled Water Insulation Sealant Chilled Water Systems 5th Level Mechanical Room
Air Handler Unit H22
NA NA
HOSP DIS DIS‐01 5 TSI Good HVAC Duct Insulation Sealant Insulated HVAC Ducts 5th Level Mechanical Room
Air Handler Unit H 28
NA NA
HOSP PPG PPG‐01 5 Misc. Good Penetration Packing
Gray Penetrations
5th Level Mechanical Room Column 33
NA NA
HOSP WPF WPF‐01 5 Misc. Good Water Proofing Sealant
Pink Concrete Seperations
5th Level Mechanical Room Column 30.5/6.6
NA NA
HOSP SAFP SAFP‐02 5 Surfacing Good Spray Applied Beige Fire Proofing Structural Supports 5th Level Mechanical Room
At Air Handler Unit H5
NA NA
HOSP JC JC‐01 5 Misc. Good Joint Compound Walls Throughout 5th Level Mechanical Room
At Air Handler Unit H5
NA NA
HOSP GDM GDM‐02 5 TSI Good Gray HVAC Duct Seam Sealant Metal HVAC Ducts 5th Level Mechanical Room Air Handler Unit AFMS‐3.2
NA NA
HOSP DIS DIS‐02 5 TSI Good HVAC Duct Insulation Sealant Insulated HVAC Ducts 5th Level Mechanical Room
Column E‐33
NA NA
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus
Order No. VA248‐17‐P‐2230
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
HOSP FS FS‐01 5 Misc. Good Red Fire Stop Penetrations 5th Level Mechanical Room
At 5A‐102
NA NA
HOSP RDS RDS‐01 5 TSI Good Roof Drain Insulation Sealant Roof Drains 5th Level Mechanical Room
Air Handler Unit H‐20
NA NA
HOSP RDS RDS‐02 5 TSI Good Roof Drain Insulation Sealant Roof Drains 4th/5th Interstitial Space
Column 32
NA NA
HOSP RDS RDS‐03 4.5 TSI Good Roof Drain Insulation Sealant Roof Drains 4th/5th Interstitial Space
Column 32
NA NA
HOSP FDIS FDIS‐01 4.5 TSI Good Foil HVAC Insulated Duct Sealant Foil Insulated HVAC Ducts 4th/5th Interstitial Space
Column 32
NA NA
HOSP WPF WPF‐02 4.5 Misc. Good Water Proofing Sealant
Pink Concrete Seperations
4th/5th Interstitial Space Column 32
NA NA
HOSP CHWS CHWS‐02 4.5 TSI Good Chilled Water Insulation Sealant Chilled Water Systems 4th/5th Interstitial Space
Column 32
NA NA
HOSP HWS HWS‐02 4.5 TSI Good Hot Water Insulation Sealant Hot Water Systems 4th/5th Interstitial Space
At Stairwell H‐F
NA NA
HOSP HWS HWS‐03 3.5 TSI Good Hot Water Insulation Sealant Hot Water Systems 3rd/4th Interstitial Space
Column D31
NA NA
HOSP FDIS FDIS‐02 3.5 TSI Good Foil HVAC Insulated Duct Sealant Foil Insulated HVAC Ducts 3rd/4th Interstitial Space
Column D31
NA NA
HOSP CHWS CHWS‐03 3.5 TSI Good Chilled Water Insulation Sealant Chilled Water Systems 3rd/4th Interstitial Space
Column B8.1
NA NA
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
HOSP WV1 WV1‐01 3.5 Misc. Good Vinyl Cove Base Mastic
Red 6" Cove Base Interstitial
3rd/4th Interstitial Space Column B8.1
NA NA
HOSP JC JC‐02 3.5 Misc. Good Joint Compound Walls Throughout 3rd/4th Interstitial Space
Column B8.1
NA NA
HOSP FS FS‐02 3.5 Misc. Good Red Fire Stop Penetrations 3rd/4th Interstitial Space
Elevator Lobby
NA NA
HOSP FDIS FDIS‐03 2.5 TSI Good Foil HVAC Insulated Duct Sealant Foil Insulated HVAC Ducts 2nd/3rd Interstitial Space
Column E33
NA NA
HOSP HWS HWS‐04 2.5 TSI Good Hot Water Insulation Sealant Hot Water Systems 2nd/3rd Interstitial Space
Column E33
NA NA
HOSP PPG PPG‐02 2.5 Misc. Good Penetration Packing
Gray Penetrations
2nd/3rd Interstitial Space Column E33
NA NA
HOSP CHWS CHWS‐04 2.5 TSI Good Chilled Water Insulation Sealant Chilled Water Systems 2nd/3rd Interstitial Space
Stairwell H‐F
NA NA
HOSP FS FS‐03 2.5 Misc. Good Red Fire Stop Penetrations 2nd/3rd Interstitial Space
Column D32
NA NA
HOSP WPF WPF‐03 2.5 Misc. Good Water Proofing Sealant
Pink Concrete Seperations
2nd/3rd Interstitial Space Column D32
NA NA
HOSP WV1 WV1‐02 2.5 Misc. Good Vinyl Cove Base Mastic
Red 6" Cove Base Interstitial
2nd/3rd Interstitial Space Elevator Lobby
NA NA
HOSP FDIS FDIS‐04 1.5 TSI Good Foil HVAC Insulated Duct Sealant Foil Insulated HVAC Ducts 1st/2nd Interstitial Space
Stairwell H‐F
NA NA
HOSP CHWS CHWS‐05 1.5 TSI Good Chilled Water Insulation Sealant Chilled Water Systems 1st/2nd Interstitial Space
Stairwell H‐F
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
HOSP GDM GDM‐03 1.5 TSI Good Gray HVAC Duct Seam Sealant Metal HVAC Ducts 1st/2nd Interstitial Space
Stairwell H‐F
NA NA
HOSP WV1 WV1‐03 1.5 Misc. Good Vinyl Cove Base Mastic
Red 6" Cove Base Interstitial
1st/2nd Interstitial Space Elevator Lobby
NA NA
HOSP DIS DIS‐03 Basement TSI Good HVAC Duct Insulation Sealant Insulated HVAC Ducts Basement Elevator Lobby NA NA
HOSP FT2 FT2‐01 4 Misc. Good Beige Vinyl 24"x24"
Hallway/Lobby Floors 4th Floor Front Lobby Area NA NA
HOSP FT1 FT1‐01 4 Misc. Good Purple Vinyl 24"x24"
Hallway/Lobby Floors 4th Floor Front Lobby Area NA NA
HOSP WF1 WF1‐01 4 Misc. Good Vinyl Flooring Wood Pattern
Hallways/Offices 4th Floor Front Lobby Waiting
Area
NA NA
HOSP SV1 SV1‐01 4 Misc. Good Sheet Vinyl Flooring
Blue Labs/Offices Room 4E‐904 NA NA
HOSP WV2 WV2‐01 4 Misc. Good Vinyl Flooring Wood Pattern Beige/Light
Hallways/Offices Hallway
Room 4E‐206
NA NA
HOSP FT1 FT1‐02 4 Misc. Good Purple Vinyl 24"x24"
Hallway/Lobby Floors 4th Floor Hallway
Stairwell H‐S
NA NA
HOSP WV2 WV2‐02 4 Misc. Good Vinyl Flooring Wood Pattern Beige/Light
Hallways/Offices 4th Floor Hallway
Stairwell H‐S
NA NA
HOSP WF1 WF1‐02 4 Misc. Good Vinyl Flooring Wood Pattern
Hallways/Offices 4th Floor Hallway
Stairwell H‐S
NA NA
HOSP CT1 CT1‐01 4 Misc. Good Ceiling Tile
2'x2' Ceilings Throughout
Hallway Room 4H‐109
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
HOSP GDM GDM‐04 4 TSI Good Gray HVAC Duct Seam Sealant Metal HVAC Ducts Hallway
Room 4H‐109
NA NA
HOSP FDIS FDIS‐05 4 TSI Good Foil HVAC Insulated Duct Sealant Foil Insulated HVAC Ducts Hallway
Room 4H‐109
NA NA
HOSP JC JC‐03 4 Misc. Good Joint Compound Walls Throughout Hallway
Room 4H‐109
NA NA
HOSP FT2 FT2‐02 4 Misc. Good Beige Vinyl 24"x24"
Hallway/Lobby Floors Hallway
Room 4E‐823
NA NA
HOSP SAFP SAFP‐03 4 Surfacing Good Spray Applied Beige Fire Proofing Structural Supports Hallway
Room 4E‐823
NA NA
HOSP FS FS‐04 4 Misc. Good Red Fire Stop Penetrations Hallway
Room 4E‐823
NA NA
HOSP WPF WPF‐04 4 Misc. Good Water Proofing Sealant
Pink Concrete Seperations
Hallway Room 4E‐823
NA NA
HOSP CT1 CT1‐02 4 Misc. Good Ceiling Tile
2'x2' Ceilings Throughout
Hallway Room 4E‐823
NA NA
HOSP JC JC‐04 4 Misc. Good Joint Compound Walls Throughout Hallway
Room 4E‐823
NA NA
HOSP JC JC‐05 3 Misc. Good Joint Compound Walls Throughout Corridor NA NA
HOSP SAFP SAFP‐04 3 Surfacing Good Spray Applied Beige Fire Proofing Structural Supports Corridor NA NA
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
HOSP CT1 CT1‐03 3 Misc. Good Ceiling Tile
2'x2' Ceilings Throughout Corridor NA NA
HOSP FDIS FDIS‐06 3 TSI Good Foil HVAC Insulated Duct Sealant Foil Insulated HVAC Ducts Corridor NA NA
HOSP SV1 SV1‐02 3 Misc. Good Sheet Vinyl Flooring
Blue Labs/Offices Corridor NA NA
HOSP FT2 FT2‐03 3 Misc. Good Beige Vinyl 24"x24"
Hallway/Lobby Floors Elevator Lobby NA NA
HOSP FT1 FT1‐03 3 Misc. Good Purple Vinyl 24"x24"
Hallway/Lobby Floors Main Lobby NA NA
HOSP WV2 WV2‐03 3 Misc. Good Vinyl Flooring Wood Pattern Beige/Light
Hallways/Offices Vending Machine Lobby NA NA
HOSP SAFP SAFP‐05 3 Surfacing Good Spray Applied Beige Fire Proofing Structural Supports Vending Machine Lobby NA NA
HOSP JC JC‐06 3 Misc. Good Joint Compound Walls Throughout Vending Machine Lobby NA NA
HOSP WPF WPF‐05 3 Misc. Good Water Proofing Sealant
Pink Concrete Seperations Vending Machine Lobby NA NA
HOSP WF1 WF1‐03 3 Misc. Good Vinyl Flooring Wood Pattern
Hallways/Offices Vending Machine Lobby NA NA
HOSP FT2 FT2‐04 3 Misc. Good Beige Vinyl 24"x24"
Hallway/Lobby Floors Vending Machine Lobby NA NA
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
HOSP FT1 FT1‐04 3 Misc. Good Purple Vinyl 24"x24"
Hallway/Lobby Floors Room 3F‐204 NA NA
HOSP SV1 SV1‐03 3 Misc. Good Sheet Vinyl Flooring
Blue Labs/Offices Room 3F‐204 NA NA
HOSP SAFP SAFP‐06 2 Surfacing Good Spray Applied Beige Fire Proofing Structural Supports Room 2J‐206 NA NA
HOSP CT1 CT1‐04 2 Misc. Good Ceiling Tile
2'x2' Ceilings Throughout Room 2J‐206 NA NA
HOSP FDIS FDIS‐07 2 TSI Good Foil HVAC Insulated Duct Sealant Foil Insulated HVAC Ducts Room 2J‐206 NA NA
HOSP JC JC‐07 2 Misc. Good Joint Compound Walls Throughout Room 2J‐206 NA NA
HOSP WF1 WF1‐04 2 Misc. Good Vinyl Flooring Wood Pattern
Hallways/Offices Hallway Outside Room 2J‐206
NA NA
HOSP FT1 FT1‐05 2 Misc. Good Purple Vinyl 24"x24"
Hallway/Lobby Floors Hallway Outside Room 2J‐206
NA NA
HOSP FT2 FT2‐05 2 Misc. Good Beige Vinyl 24"x24"
Hallway/Lobby Floors Hallway Outside Room 2J‐206
NA NA
HOSP WV2 WV2‐04 2 Misc. Good Vinyl Flooring Wood Pattern Beige/Light
Hallways/Offices Hallway Outside Room 2B‐502
NA NA
HOSP WF1 WF1‐05 2 Misc. Good Vinyl Flooring Wood Pattern
Hallways/Offices Elevator Lobby NA NA
HOSP CT1 CT1‐05 2 Misc. Good Ceiling Tile
2'x2' Ceilings Throughout Elevator Lobby NA NA
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
HOSP FT2 FT2‐06 2 Misc. Good Beige Vinyl 24"x24"
Hallway/Lobby Floors Hallway NA NA
HOSP SAFP SAFP‐07 2 Surfacing Good Spray Applied Beige Fire Proofing Structural Supports Hallway NA NA
HOSP FT1 FT1‐06 2 Misc. Good Purple Vinyl 24"x24"
Hallway/Lobby Floors Hallway NA NA
HOSP CT1 CT1‐06 2 Misc. Good Ceiling Tile
2'x2' Ceilings Throughout Room 2K‐508 NA NA
HOSP WF1 WF1‐06 1 Misc. Good Vinyl Flooring Wood Pattern
Hallways/Offices Elevator Lobby NA NA
HOSP CT1 CT1‐07 1 Misc. Good Ceiling Tile
2'x2' Ceilings Throughout Elevator Lobby NA NA
HOSP JC JC‐08 1 Misc. Good Joint Compound Walls Throughout Room 2J‐206 NA NA
HOSP SV1 SV1‐04 1 Misc. Good Sheet Vinyl Flooring
Blue Labs/Offices Pass Through Foyor NA NA
HOSP ST ST‐01 1 TSI Good Steam Insulation Sealant Steam Mechanical Systems Warehouse
Sprinkler Riser Room
NA NA
HOSP ST ST‐02 1 TSI Good Steam Insulation Sealant Steam Mechanical Systems Warehouse
Sprinkler Riser Room
NA NA
HOSP ST ST‐03 1 TSI Good Steam Insulation Sealant Steam Mechanical Systems Warehouse
Sprinkler Riser Room
NA NA
HOSP CHWS CHWS‐06 1 TSI Good Chilled Water Insulation Sealant Chilled Water Systems Warehouse
Sprinkler Riser Room
NA NA
HOSP CHWS CHWS‐07 1 TSI Good Chilled Water Insulation Sealant Chilled Water Systems Warehouse
Sprinkler Riser Room
NA NA
HOSP HWS HWS‐05 1 TSI Good Hot Water Insulation Sealant Hot Water Systems Warehouse
Sprinkler Riser Room
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
HOSP HWS HWS‐06 1 TSI Good Hot Water Insulation Sealant Hot Water Systems Warehouse
Sprinkler Riser Room
NA NA
HOSP FS FS‐05 1 Misc. Good Red Fire Stop Penetrations Warehouse
Sprinkler Riser Room
NA NA
HOSP SV1 SV1‐05 1 Misc. Good Sheet Vinyl Flooring
Blue Labs/Offices
Warehouse Laundry Room
NA NA
HOSP JC JC‐09 1 Misc. Good Joint Compound Walls Throughout Warehouse/Hospital Hallway Pass Through
NA NA
HOSP SAFP SAFP‐08 1 Surfacing Good Spray Applied Beige Fire Proofing Structural Supports Warehouse/Hospital Hallway Pass Through
NA NA
HOSP HWS HWS‐07 1 TSI Good Hot Water Insulation Sealant Hot Water Systems Pump Room Room 1N‐301
NA NA
HOSP JC JC‐10 1 Misc. Good Joint Compound Walls Throughout Pump Room Room 1N‐301
NA NA
HOSP PPG PPG‐03 5 Misc. Good Penetration Packing
Gray Penetrations At Elevator NA NA
HOSP DIS DIS‐04 5 TSI Good HVAC Duct Insulation Sealant Insulated HVAC Ducts 5th Level Mechanical Room NA NA
HOSP DIS DIS‐05 5 TSI Good HVAC Duct Insulation Sealant Insulated HVAC Ducts 5th Level Mechanical Room
Air Handler Unit 5
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Clin DIS DIS‐01 5 TSI Good HVAC Duct Insulation Sealant
White HVAC Insulated Ducts
5th Floor Mechanical Room Air Handler Unit C1
NA NA
Clin CHWS CHWS‐01 5 TSI Good Chilled Water Insulation Sealant Chilled Water Systems 5th Floor Mechanical Room
Air Handler Unit C1
NA NA
Clin GDM GDM‐01 5 TSI Good Gray Metal HVAC Duct Seam Sealant Metal HVAC Ducts 5th Floor Mechanical Room
Air Handler Unit C1
NA NA
Clin DIS DIS‐02 5 TSI Good HVAC Duct Insulation Sealant
White HVAC Insulated Ducts
5th Floor Mechanical Room Air Handler Unit C1
NA NA
Clin CHWS CHWS‐02 5 TSI Good Chilled Water Insulation Sealant Chilled Water Systems 5th Floor Mechanical Room
Fan Coil
NA NA
Clin GDM GDM‐02 5 TSI Good Gray Metal HVAC Duct Seam Sealant Metal HVAC Ducts 5th Floor Mechanical Room
Air Handler Unit C2
NA NA
Clin PPG PPG‐01 5 Misc. Good Penetration Packing
Gray Penetration Packing
5th Floor Mechanical Room Air Handler Unit C2
NA NA
Clin DIS DIS‐03 5 TSI Good HVAC Duct Insulation Sealant
White HVAC Insulated Ducts
5th Floor Mechanical Room Air Handler Unit C17
NA NA
Clin HWS HWS‐01 5 TSI Good Hot Water Insulation Sealant Hot Water Mechanical Systems 5th Floor Mechanical Room
Air Handler Unit C10
NA NA
Clin CHWS CHWS‐03 5 TSI Good Chilled Water Insulation Sealant Chilled Water Systems 5th Floor Mechanical Room
Air Handler Unit C17
NA NA
Clin HWS HWS‐02 5 TSI Good Hot Water Insulation Sealant Hot Water Mechanical Systems 5th Floor Mechanical Room
Air Handler Unit C6
NA NA
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
Clin PPG PPG‐02 5 Misc. Good Penetration Packing
Gray Penetration Packing
5th Floor Mechanical Room Air Handler Unit C10
NA NA
Clin JC JC‐01 5 Misc. Good Joint Compound Walls Throughout 5th Floor Mechanical Room
At Elevator
NA NA
Clin SAFP SAFP‐01 5 Surfacing Good Spray Applied Fire Proofing Steal Structural Beams 5th Floor Mechanical Room Hallway Connecting Areas
NA NA
Clin SAFP SAFP‐02 5 Surfacing Good Spray Applied Fire Proofing Steal Structural Beams 5th Floor Mechanical Room Hallway Connecting Areas
NA NA
Clin FS FS‐01 5 Misc. Good Fire Stop
Red Penetrations
5th Floor Mechanical Room At Elevator
NA NA
Clin FSL FSL‐01 5 Misc. Good Pink Fire Sealant Structural Gaps 5th Floor Mechanical Room
At Elevator
NA NA
Clin RDS RDS‐01 4.5 TSI Good Roof Drain Insulation Sealant Roof Drain Insulation 4th/5th Interstitial
Column C27
NA NA
Clin FSL FSL‐02 4.5 Misc. Good Pink Fire Sealant Structural Gaps Stairwell NA NA
Clin FDIS FDIS‐01 4.5 TSI Good HVAC Foil Duct Insulation Sealant Foil Insulation HVAC Duct
Insulation Sealant 4th/5th Interstitial
Column C27
NA NA
Clin RDS RDS‐02 4.5 TSI Good Roof Drain Insulation Sealant Roof Drain Insulation 4th/5th Interstitial
Column C27
NA NA
Clin HWS HWS‐03 4.5 TSI Good Hot Water Insulation Sealant Hot Water Mechanical Systems 4th/5th Interstitial
Column C27
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
Clin FS FS‐02 4.5 Misc. Good Fire Stop
Red Penetrations
4th/5th Interstitial Column C25
NA NA
Clin DHWS DHWS‐01 3.5 TSI Good Domestic Hot Water Insulation
Sealant Domestic Hot Water Mechanical Systems
3rd/4th Floor Interstitial Column C26
NA NA
Clin FDIS FDIS‐02 3.5 TSI Good HVAC Foil Duct Insulation Sealant Foil Insulation HVAC Duct
Insulation Sealant 3rd/4th Floor Interstitial
Column C26
NA NA
Clin GDM GDM‐03 3.5 TSI Good Gray Metal HVAC Duct Seam Sealant Metal HVAC Ducts 3rd/4th Floor Interstitial
Column C26
NA NA
Clin DHWS DHWS‐02 3.5 TSI Good Domestic Hot Water Insulation
Sealant Domestic Hot Water Mechanical Systems
3rd/4th Floor Interstitial Column C26
NA NA
Clin FSL FSL‐03 3.5 Misc. Good Pink Fire Sealant Structural Gaps 3rd/4th Floor Interstitial
Column C26
NA NA
Clin HWS HWS‐04 3.5 TSI Good Hot Water Insulation Sealant Hot Water Mechanical Systems 3rd/4th Floor Interstitial
Column C26
NA NA
Clin DHWS DHWS‐03 2.5 TSI Good Domestic Hot Water Insulation
Sealant Domestic Hot Water Mechanical Systems
2nd/3rd Floor Interstitial Column C25
NA NA
Clin HWS HWS‐02 2.5 TSI Good Hot Water Insulation Sealant Hot Water Mechanical Systems 2nd/3rd Floor Interstitial
Column C24
NA NA
Clin GDM GDM‐04 2.5 TSI Good Gray Metal HVAC Duct Seam Sealant Metal HVAC Ducts 2nd/3rd Floor Interstitial
Column C26
NA NA
Clin JC JC‐02 1.5 Misc. Good Joint Compound Walls Throughout 1st/2nd Floor Interstitial
Column C27
NA NA
Clin CHWS CHWS‐04 1.5 TSI Good Chilled Water Insulation Sealant Chilled Water Systems 1st/2nd Floor Interstitial
Column C27
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
Clin FS FS‐03 1.5 Misc. Good Fire Stop
Red Penetrations
1st/2nd Floor Interstitial Elevator Lobby
NA NA
Clin FT1 FT1‐01 4 Misc. Good Vinyl Floor Tile
18"x18" Beige/Green
Hallway/Office Floors Elevator Lobby NA NA
Clin SAFP SAFP‐03 4 Surfacing Good Spray Applied Fire Proofing Steal Structural Beams Main Hallway NA NA
Clin JC JC‐03 4 Misc. Good Joint Compound Walls Throughout Main Hallway NA NA
Clin CT CT‐01 4 Misc. Good Ceiling Tile
2'x2' Beveled Edge Ceilings Throughout Main Hallway NA NA
Clin FT2 FT2‐01 4 Misc. Good Vinyl Floor Tile
18"x18" Bamboo
Hallway/Office Floors Elevator Lobby NA NA
Clin FDIS FDIS‐03 3 TSI Good HVAC Foil Duct Insulation Sealant Foil Insulation HVAC Duct
Insulation Sealant 3rd Floor Hallway At Room 3G‐809
NA NA
Clin WF WF‐01 3 Misc. Good Vinyl Floor
Wood Pattern Hallway/Office Floors
3rd Floor Hallway At Room 3G‐809
NA NA
Clin FT1 FT1‐02 3 Misc. Good Vinyl Floor Tile
18"x18" Beige/Green
Hallway/Office Floors 3rd Floor Hallway At Room 3G‐809
NA NA
Clin CT CT‐02 3 Misc. Good Ceiling Tile
2'x2' Beveled Edge Ceilings Throughout
3rd Floor Hallway At Room 3G‐809
NA NA
Clin JC JC‐04 3 Misc. Good Joint Compound Walls Throughout 3rd Floor Hallway At Room 3G‐809
NA NA
Clin SAFP SAFP‐04 3 Surfacing Good Spray Applied Fire Proofing Steal Structural Beams 3rd Floor Hallway At Room 3G‐809
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
Clin JC JC‐05 2 Misc. Good Joint Compound Walls Throughout 2nd Floor Hallway At Room 2F‐208
NA NA
Clin FDIS FDIS‐04 2 TSI Good HVAC Foil Duct Insulation Sealant Foil Insulation HVAC Duct
Insulation Sealant 2nd Floor Hallway At Room 2F‐208
NA NA
Clin FT1 FT1‐03 2 Misc. Good Vinyl Floor Tile
18"x18" Beige/Green
Hallway/Office Floors 2nd Floor Hallway At Room 2F‐204
NA NA
Clin WF WF‐02 3 Misc. Good Vinyl Floor
Wood Pattern Hallway/Office Floors
2nd Floor Hallway At Room 2F‐204
NA NA
Clin CT CT‐03 2 Misc. Good Ceiling Tile
2'x2' Beveled Edge Ceilings Throughout
2nd Floor Hallway At Room 2F‐202
NA NA
Clin SAFP SAFP‐05 2 Surfacing Good Spray Applied Fire Proofing Steal Structural Beams 2nd Floor Hallway At Room 2F‐210
NA NA
Clin FT1 FT1‐04 2 Misc. Good Vinyl Floor Tile
18"x18" Beige/Green
Hallway/Office Floors 2nd Floor Hallway At Room 2C‐214
NA NA
Clin WF WF‐03 2 Misc. Good Vinyl Floor
Wood Pattern Hallway/Office Floors
2nd Floor Hallway At Room 2C‐214
NA NA
Clin JC JC‐06 2 Misc. Good Joint Compound Walls Throughout 2nd Floor Hallway At Room 2C‐214
NA NA
Clin CT CT‐04 2 Misc. Good Ceiling Tile
2'x2' Beveled Edge Ceilings Throughout
2nd Floor Hallway At Room 2C‐214
NA NA
Clin SAFP SAFP‐06 2 Surfacing Good Spray Applied Fire Proofing Steal Structural Beams 2nd Floor Hallway At Room 2C‐214
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
Clin SAFP SAFP‐07 1 Surfacing Good Spray Applied Fire Proofing Steal Structural Beams 1st Floor Hallway At Room 1B‐809
NA NA
Clin FDIS FDIS‐05 1 TSI Good HVAC Foil Duct Insulation Sealant Foil Insulation HVAC Duct
Insulation Sealant 1st Floor Hallway At Room 1B‐809
NA NA
Clin CT CT‐05 1 Misc. Good Ceiling Tile
2'x2' Beveled Edge Ceilings Throughout
1st Floor Hallway At Room 1B‐809
NA NA
Clin FT1 FT1‐05 1 Misc. Good Vinyl Floor Tile
18"x18" Beige/Green
Hallway/Office Floors 1st Floor Hallway At Room 1B‐309
NA NA
Clin WF WF‐04 1 Misc. Good Vinyl Floor
Wood Pattern Hallway/Office Floors
1st Floor Hallway At Room 1B‐309
NA NA
Clin WTX WTX‐01 1 Misc. Good Wall Texture Elevator Lobby Elevator Lobby Center Lobby NA NA
Clin WTX WTX‐02 1 Misc. Good Wall Texture Elevator Lobby Elevator Lobby Center Lobby NA NA
Clin SAFP SAFP‐08 1 Surfacing Good Spray Applied Fire Proofing Steal Structural Beams 1st Floor Hallway At Room 1B‐809
NA NA
Clin CT CT‐06 1 Misc. Good Ceiling Tile
2'x2' Beveled Edge Ceilings Throughout
1st Floor Hallway At Room 1B‐809
NA NA
Clin WF WF‐05 1 Misc. Good Vinyl Floor
Wood Pattern Hallway/Office Floors
1st Floor Hallway At Room 1B‐809
NA NA
Clin FDIS FDIS‐06 1 TSI Good HVAC Foil Duct Insulation Sealant Foil Insulation HVAC Duct
Insulation Sealant 1st Floor Hallway At Room 1B‐809
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
Clin JC JC‐07 1 Misc. Good Joint Compound Walls Throughout 1st Floor Hallway At Room 1B‐809
NA NA
Clin WTX WTX‐03 1 Misc. Good Wall Texture Elevator Lobby Elevator Lobby Center Lobby NA NA
Clin WTX WTX‐04 4 Misc. Good Wall Texture Elevator Lobby 4th Floor
Cross Over Hallway
NA NA
Clin WV1 WV1‐01 4 Misc. Good Vinyl Cove Base Mastic
4" Rust Colored Stairwells West Stairwell NA NA
Clin WV1 WV1‐02 3 Misc. Good Vinyl Cove Base Mastic
4" Rust Colored Stairwells West Stairwell NA NA
Clin WV1 WV1‐03 3 Misc. Good Vinyl Cove Base Mastic
4" Rust Colored Stairwells West Stairwell NA NA
Clin WV1 WV1‐04 2 Misc. Good Vinyl Cove Base Mastic
4" Rust Colored Stairwells West Stairwell NA NA
Clin WV1 WV1‐05 1 Misc. Good Vinyl Cove Base Mastic
4" Rust Colored Stairwells West Stairwell NA NA
Clin WTX WTX‐05 3 Misc. Good Wall Texture Elevator Lobby Elevator Lobby West Cross Over Hallway
NA NA
Clin WTX WTX‐06 3 Misc. Good Wall Texture Elevator Lobby 3rd Floor
Cross Over Hallway
NA NA
Clin RDS RDS‐03 5 TSI Good Roof Drain Insulation Sealant Roof Drain Insulation 5th Floor
Column C‐26
NA NA
Clin CHWS CHWS‐05 5 TSI Good Chilled Water Insulation Sealant Chilled Water Systems 5th Floor
Column C‐24
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
Clin GDM GDM‐05 5 TSI Good Gray Metal HVAC Duct Seam Sealant Metal HVAC Ducts 5th Floor
Column C‐24
NA NA
Clin PPG PPG‐03 5 Misc. Good Penetration Packing
Gray Penetration Packing
5th Floor Mechanical Room Air Handler Unit C17
NA NA
Clin DIS DIS‐04 5 TSI Good HVAC Duct Insulation Sealant
White HVAC Insulated Ducts
5th Floor Mechanical Room Air Handler Unit C2
NA NA
Clin DIS DIS‐05 5 TSI Good HVAC Duct Insulation Sealant
White HVAC Insulated Ducts
5th Floor Mechanical Room Air Handler Unit C2
NA NA
Clin FS FS‐04 3.5 Misc. Good Fire Stop
Red Penetrations 3rd/4th Interstitial NA NA
Clin FSL FSL‐04 4.5 Misc. Good Pink Fire Sealant Structural Gaps 4th/5th Interstitial NA NA
Clin FS FS‐05 4.5 Misc. Good Fire Stop
Red Penetrations 4th/5th Interstitial NA NA
Clin FSL FSL‐05 1.5 Misc. Good Pink Fire Sealant Structural Gaps 1st/2nd Interstitial NA NA
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
CLC WF WF‐01 1 Misc. Good Vinyl Flooring Wood Pattern
Hallways Hallway At Main Mechanical
Room
NA NA
CLC ST ST‐01 1 TSI Good White Steam Line Insulation Sealant Mechanical Room
Steam Lines Mechanical Room
At Converter Assembly
NA NA
CLC ST ST‐02 1 TSI Good White Steam Line Insulation Sealant Mechanical Room
Steam Lines Mechanical Room
At Converter Assembly
NA NA
CLC ST ST‐03 1 TSI Good White Steam Line Insulation Sealant Mechanical Room
Steam Lines Mechanical Room
At Converter Assembly
NA NA
CLC DIS DIS‐01 1 TSI Good Duct Insulation Sealant Mechanical Room
HVAC Ducts Mechanical Room
Adjacent To Steam Lines
NA NA
CLC DIS DIS‐02 1 TSI Good Duct Insulation Sealant Mechanical Room
HVAC Ducts Mechanical Room Air Handler Unit 5
NA NA
CLC DIS DIS‐03 1 TSI Good Duct Insulation Sealant Mechanical Room
HVAC Ducts Mechanical Room Air Handler Unit 5
NA NA
CLC CHWS CHWS‐01 1 TSI Good Chilled Water Insulation Sealant Mechanical Rooms Chilled Water Lines
Mechanical Room Air Handler Unit 5
NA NA
CLC CHWS CHWS‐02 1 TSI Good Chilled Water Insulation Sealant Mechanical Rooms Chilled Water Lines
Mechanical Room Air Handler Unit 5
NA NA
CLC CHWS CHWS‐03 1 TSI Good Chilled Water Insulation Sealant Mechanical Rooms Chilled Water Lines
Mechanical Room Air Handler Unit 5
NA NA
CLC HWS HWS‐01 1 TSI Good Hot Water Line Insulation Sealant Mechanical Rooms Hot Water Lines
Mechanical Room Main
NA NA
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
CLC HWS HWS‐02 1 TSI Good Hot Water Line Insulation Sealant Mechanical Rooms Hot Water Lines
Mechanical Room NA NA
CLC HWS HWS‐03 1 TSI Good Hot Water Line Insulation Sealant Mechanical Rooms Hot Water Lines
Mechanical Room NA NA
CLC CT1 CT1‐01 1 Misc. Good Ceiling Tile Ceilings Throughout Room 1A‐611 NA NA
CLC WPF WPF‐01 1 Surfacing Good Wall Plaster Finish Hallway Corridor Walls Hallway Corridor NA NA
CLC WPF WPF‐02 1 Surfacing Good Wall Plaster Finish Hallway Corridor Walls Hallway Corridor NA NA
CLC WPF WPF‐03 1 Surfacing Good Wall Plaster Finish Hallway Corridor Walls Hallway Corridor NA NA
CLC FT1 FT1‐01 1 Misc. Good Floor Tile Beige Gray Central Gathering Areas Room 1B‐401 NA NA
CLC FT1 FT1‐02 1 Misc. Good Floor Tile Beige Gray Central Gathering Areas Room 1B‐014 NA NA
CLC WP WP‐01 1 Surfacing Good Wall Plaster Central Hallway Outside Mechanical Room
1B‐001
NA NA
CLC WP WP‐02 1 Surfacing Good Wall Plaster Central Hallway Outside Mechanical Room
1B‐001
NA NA
CLC WP WP‐03 1 Surfacing Good Wall Plaster Central Hallway Outside Mechanical Room
1B‐001
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of Material Sample Location Quantity % Asbestos
Department of Veterans Affairs Orlando VA Medical Center
Lake Nona Campus Orlando, FL 32827
Order No. VA248‐17‐P‐2230
CLC JC JC‐01 1 Misc. Good Joint Compound Walls Throughout Entrance to Sunrise Villas NA NA
CLC WF WF‐02 1 Misc. Good Vinyl Flooring Wood Pattern
Hallway Floors Main Hallway NA NA
CLC WF WF‐03 1 Misc. Good Vinyl Flooring Wood Pattern
Hallway Floors Room 1D‐402 NA NA
CLC JC JC‐02 1 Misc. Good Joint Compound Walls Throughout Room 1D‐402 NA NA
CLC JC JC‐03 1 Misc. Good Joint Compound Walls Throughout Hallway At Blue Water Village NA NA
CLC WF WF‐04 1 Misc. Good Vinyl Flooring Wood Pattern
Hallway Floors Hallway At Blue Water Village NA NA
CLC WF WF‐05 1 Misc. Good Vinyl Flooring Wood Pattern
Hallway Floors Hallway At Room 1H‐034 NA NA
CLC JC JC‐04 1 Misc. Good Joint Compound Walls Throughout Hallway At Room 1H‐034 NA NA
CLC JC JC‐05 1 Misc. Good Joint Compound Walls Throughout Hallway At Room 1G‐016 NA NA
CLC WF WF‐06 1 Misc. Good Vinyl Flooring Wood Pattern
Hallway Floors Hallway At Room 1G‐016 NA NA
CLC CHWS CHWS‐04 1 TSI Good Chilled Water Insulation Sealant Mechanical Rooms Air Handler Unit 3 Room 1D‐002
Sample
HA
Sample Number
Floor No.
AHERA
Categories of Asbestos
Material Condition
Sample Description (Material Type, Size, Texture, Color)
Location of…