This document is a detailed Pricing Worksheet (Attachment 7) for a federal contract opportunity involving preventive and corrective maintenance of fuel infrastructure for the U.S. Air Force in the South Atlantic Division. The worksheet includes comprehensive pricing breakdowns across multiple contract line item numbers (CLINs) for base year and four option years, covering quarterly, semi-annual, and annual preventive maintenance, corrective maintenance, other direct costs, and irregular preventive maintenance. The total estimated corrective maintenance amount is $52,153,302.00, with pricing structured across 17 specific Air Force sites including locations in Florida, Georgia, South Carolina, and other regional facilities.

The pricing template requires contractors to input unit prices for numerous specific maintenance categories, such as valve replacements, bollard repairs, hose replacements, signage, and various technical component repairs. The contract period appears to run from February 2026 to August 2029, with escalation rates set at 0%. The worksheet includes detailed instructions for completing pricing information, emphasizing that all administrative and supervisory oversight beyond key personnel should be included in service order fees. Labor categories range from Program Manager to Fuel Maintenance Technician, with specific experience and qualification requirements for each role.

View the file

Other files

File Type Posted
Shaw AFB SC (SHW)-FMP.xlsx XLSX spreadsheet
Moody AFB GA (MDY)-FMP.xlsx XLSX spreadsheet
Robins AFB GA (ROB-TBD)-FMP.xlsx XLSX spreadsheet
CDRL Set 15 57-60.pdf PDF
CDRL Set 2 5-8.pdf PDF
CDRL Set 3 9-12.pdf PDF
CDRL Set 9 33-36.pdf PDF
CDRL Set 6 21-24.pdf PDF
Douglas MAP ANG NC (DGL)-FMP.xlsx XLSX spreadsheet
Dobbins ARB GA (DOB)-FMP.xlsx XLSX spreadsheet
McEntire ANG SC (MNT)-FMP.xlsx XLSX spreadsheet
Attachment 2 Sample Service Order (Appendix A - Attachment 1 Service Order Form).xlsx XLSX spreadsheet
Attachment 1 Performance Work Statement SAD-AF2.pdf PDF
Fuels SAD-AF2 Draft Solicitation W912DY26RA017.pdf PDF
Attachment 5 Instructions and Evaluation Factors.pdf PDF
CDRL Set 1 1-4.pdf PDF
CDRL Set 12 45-48.pdf PDF
CDRL Set 5 17-20.pdf PDF
CDRL Set 10 37-40.pdf PDF
CDRL Set 17 65-67.pdf PDF
CDRL Set 11 41-44.pdf PDF
Seymour Johnson AFB NC (SMJ)-FMP.xlsx XLSX spreadsheet
Joint Base Charleston SC (JBC)-FMP.xlsx XLSX spreadsheet
2.1 Appendix A - Attachment 1 Service Order Form-v11.5_20251027.xlsx XLSX spreadsheet
Attachment 8 Small Business Participation Plan Template.pdf PDF
Stanly County Airport NC (WEF)-FMP.xlsx XLSX spreadsheet
Glynco ANG Station GA (JAS)-FMP.xlsx XLSX spreadsheet
Cape Canaveral AFS FL (DBE)-FMP.xlsx XLSX spreadsheet
Attachment 6 Draft QASP.pdf PDF
Attachment 4 - PPQ Sample (3).pdf PDF
DFSP Charleston SC (CHS)-FMP.xlsx XLSX spreadsheet
CDRL Set 16 60-64.pdf PDF
Attachment 3 Technical Evaluation Form.pdf PDF
Savannah ANG GA (SAG)-FMP.xlsx XLSX spreadsheet
Savannah-Hilton Head GA (SHH)-FMP.xlsx XLSX spreadsheet
Charleston AFB SC (CAF)-FMP.xlsx XLSX spreadsheet
CDRL Set 13 49-52.pdf PDF
CDRL Set 4 13-16.pdf PDF
CDRL Set 7 25-28.pdf PDF
CDRL Set 8 29-32.pdf PDF
CDRL Set 14 53-56.pdf PDF
12.0 PWS Appendix K SAD-AF2 Real Property Data SAD-AF2 Final 20250225.xlsx XLSX spreadsheet
Jacksonville IAP FL (JVL)-FMP.xlsx XLSX spreadsheet
Patrick AFB FL (PAT)-FMP.xlsx XLSX spreadsheet
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUMMARY

CONTRACTOR:Input Contractor Name
SOLICITATION REFERENCE NUMBER:Input Solicitation Number
DATEInput Submittal Date
INSTRUCTIONS- Complete instructions for each tab of the pricing worksheet. The Offeror is instructed to complete the provided fields in GREEN for each tab of the pricing worksheet. Pricing within the Summary tab is populated from the CLIN ROLL UP TAB. All pricing cells on this sheet are automated.
PREVENTIVE AND CORRECTIVE MAINTENANCE SUMMARY
CLIN X001 - QUARTERLY PREVENTIVE MAINTENANCETotal
BASE YEAROPT 1OPT 2OPT 3 (6MN PERIOD)6 MONTH EXTCLIN X001
CLIN X001 TOTAL$ - 0$ - 0$ - 0$ - 0$ - 0$ -
CLIN X002 - SEMI ANNUAL PREVENTIVE MAINTENANCETotal
BASE YEAROPT 1OPT 2OPT 3 (6MN PERIOD)6 MONTH EXTCLIN X002
CLIN X002 TOTAL$ - 0$ - 0$ - 0$ - 0$ - 0$ -
CLIN X003 - ANNUAL PREVENTIVE MAINTENANCETotal
BASE YEAROPT 1OPT 2OPT 3 (6MN PERIOD)6 MONTH EXTCLIN X003
CLIN X003 TOTAL$ - 0$ - 0$ - 0$ - 0$ - 0$ -19512991.3333333
20279510.986666719512991.333333320279510.986666721076691.426133321905759.083178722767989.4465058
CLIN X004 - CORRECTIVE MAINTENANCE- DO NOT PRICETotal21076691.4261333
CLIN X004 TOTAL:BASE YEAROPT 1OPT 2OPT 3 (6MN PERIOD)6 MONTH EXTCLIN X00421905759.0831787
$52,153,302.0022767989.4465058
ESTIMATED - FOR EVALUATION PURPOSES ONLY
CLIN X005 - OTHER DIRECT COSTSTotal
BASE YEAROPT 1OPT 2OPT 3 (6MN PERIOD)6 MONTH EXTCLIN X0050.05
CLIN X005 TOTAL$ - 0$ - 0$ - 0$ - 0$ - 0$ -
CLIN X006 - IRREGULAR PREVENTIVE MAINTENANCETotal
BASE YEAROPT 1OPT 2OPT 3 (6MN PERIOD)6 MONTH EXTCLIN X006
CLIN X006 TOTAL:$ - 0$ - 0$ - 0$ - 0$ - 0$ -

TOTAL: $ - $ - $ - $ - $ - $ 52,153,302

CUI

POJ IGE

&A

CUI

CLIN ROLL UP

INSTRUCTIONS - Complete the provided fields in GREEN. This section identifies a roll-up of all other sections in this pricing worksheet. Pricing at this level must be rounded to the nearest cent. The CLIN Roll-Up totals in this section are transferred to the summary section which identifies the overall cost proposed for this Task Order. Note: Pricing within this sheet is populated from pricing data from each CLIN tab. The Contractor is responsible for ensuring all pricing of CLINs, calculations, and other added cells are captured correctly in the CLIN Roll-Up section. The pricing presented here governs at award.

Note: The Total Estimated Preventive Maintenance Hours (Key Personnel and onsite labor) are provided for general awareness and may not fully reflect the comprehensive effort for preventative maintenance requirements. Offerors are strongly encouraged to thoroughly review the Performance Work Statement (PWS) and associated attachments to formulate their best and final offer.

CLIN ROLL-UP
Contractor:
Solicitation Number:
Total Estimated Hours:73,640hrs (estimated 18,410 hrs/yr)
CLIN X001 - QUARTERLY PREVENTIVE MAINTENANCE
KEY PERSONNEL TOTALS:BASE YEAROPT 1OPT 2OPT 3 (6MN PERIOD)6 MONTH EXT
$ - 0$ - 0$ - 0$ - 0$ - 0
SITEDLA SITE CODERPSUIDSERVICEBASE YEAROPT 1OPT 2OPT 3 (6MN PERIOD)6 MONTH EXT
TOTAL PREVENTIVE MAINTENANCE:$ - 0$ - 0$ - 0$ - 0$ - 0
Jacksonville IAP Site #1JVL2390AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Cape Canaveral AFS Site #1DBE1555AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Patrick AFBPAT3143AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Charleston AFB (ID 26) - Joint BaseCAF1579AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
DFSP CharlestonCHS1580AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Douglas MAP ANG (ID 146)DGL1661AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Dobbins ARB (ID 192)DOB1660AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Glynco ANG StationJAS2124AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Joint Base Charleston NWSJBC213AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Moody AFBMDY3020AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
McEntire ANG (ID 158)MNT2793AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Robins AFBRBA3219AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Savannah ANG (IAP ID 107)SAG3358AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Savannah/Hilton Head IAP Site #3SHH17105AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Shaw AFB (ID 55)SHW3269AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Seymour Johnson AFB (ID 56)SMJ3268AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Stanly County AirportWEF3312AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
CLIN X002 - SEMI ANNUAL PREVENTIVE MAINTENANCE
KEY PERSONNEL TOTALS:BASE YEAROPT 1OPT 2OPT 3 (6MN PERIOD)6 MONTH EXT
$ - 0$ - 0$ - 0$ - 0$ - 0
SITEDLA SITE CODERPSUIDSERVICEBASE YEAROPT 1OPT 2OPT 3 (6MN PERIOD)6 MONTH EXT
TOTAL PREVENTIVE MAINTENANCE:$ - 0$ - 0$ - 0$ - 0$ - 0
Jacksonville IAP Site #1JVL2390AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Cape Canaveral AFS Site #1DBE1555AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Patrick AFBPAT3143AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Charleston AFB (ID 26) - Joint BaseCAF1579AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
DFSP CharlestonCHS1580AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Douglas MAP ANG (ID 146)*DGL1661AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Dobbins ARB (ID 192)*DOB1660AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Glynco ANG StationJAS2124AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Joint Base Charleston NWSJBC213AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Moody AFBMDY3020AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
McEntire ANG (ID 158)*MNT2793AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Robins AFBRBA3219AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Savannah ANG (IAP ID 107) *SAG3358AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Savannah/Hilton Head IAP Site #3SHH17105AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Shaw AFB (ID 55)SHW3269AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Seymour Johnson AFB (ID 56) *SMJ3268AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Stanly County AirportWEF3312AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
CLIN X003 - ANNUAL PREVENTIVE MAINTENANCE
KEY PERSONNEL TOTALS:BASE YEAROPT 1OPT 2OPT 3 (6MN PERIOD)6 MONTH EXT
$ - 0$ - 0$ - 0$ - 0$ - 0
SITEDLA SITE CODERPSUIDSERVICEBASE YEAROPT 1OPT 2OPT 3 (6MN PERIOD)6 MONTH EXT
TOTAL PREVENTIVE MAINTENANCE:$ - 0$ - 0$ - 0$ - 0$ - 0
Jacksonville IAP Site #1JVL2390AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Cape Canaveral AFS Site #1DBE1555AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Patrick AFBPAT3143AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Charleston AFB (ID 26) - Joint BaseCAF1579AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
DFSP CharlestonCHS1580AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Douglas MAP ANG (ID 146)DGL1661AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Dobbins ARB (ID 192)DOB1660AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Glynco ANG StationJAS2124AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Joint Base Charleston NWSJBC213AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Moody AFBMDY3020AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
McEntire ANG (ID 158)MNT2793AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Robins AFBRBA3219AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Savannah ANG (IAP ID 107)SAG3358AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Savannah/Hilton Head IAP Site #3SHH17105AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Shaw AFB (ID 55)SHW3269AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Seymour Johnson AFB (ID 56)SMJ3268AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Stanly County AirportWEF3312AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
CORRECTIVE MAINTENANCE PRICE LIST
CATEGORYBASE YEAROPT 1OPT 2OPT 3 (6MN PERIOD)6 MONTH EXT
TOTAL:$ - 0$ - 0$ - 0$ - 0$ - 0
Air eliminators$ - 0$ - 0$ - 0$ - 0$ - 0
Bollards - Repair includes Prep and Recoat one Bollard up to 6" diameter and 48" tall or provide plastic cover for same. Applicable markings are included as part of repair.$ - 0$ - 0$ - 0$ - 0$ - 0
Deadman (Hydraulic) - Includes replacement of Deadman Handle and Cord/Hose.$ - 0$ - 0$ - 0$ - 0$ - 0
Deadman (Electronic) - Includes replacement of Deadman Handle and Cord/Hose.$ - 0$ - 0$ - 0$ - 0$ - 0
Dispenser Breakaway Connections - Includes Replacement of 1 Breakaway for Hoses ≤ 2".$ - 0$ - 0$ - 0$ - 0$ - 0
Dispenser Hose Retractors - Includes Replacement of 1 Retractor ≤ 10' in length.$ - 0$ - 0$ - 0$ - 0$ - 0
Dispenser Hose Swivels - Includes Replacement of 1 Swivel for Hoses ≤ 2".$ - 0$ - 0$ - 0$ - 0$ - 0
Dispenser Nozzles - Includes Replacement of 1 Dispenser Nozzle for Hoses ≤ 2".$ - 0$ - 0$ - 0$ - 0$ - 0
Emergency Fuel Shutoff (EFSO) Pushbutton Station - Includes Replacement and Wiring of Emergency Shuttoff Pushbutton Switch and Cover. Does not include troubleshooting or replacing wiring between EFSO Pushbutton and control panel.$ - 0$ - 0$ - 0$ - 0$ - 0
Flange Isolation Kit - 1 Repair includes complete isolation kit for a flanged connection (Gasket, Sleeves, Insulating Washers, etc.) for up to 8" piping.$ - 0$ - 0$ - 0$ - 0$ - 0
Flow Indicator Sight Glass Replacement$ - 0$ - 0$ - 0$ - 0$ - 0
Fuel Hoses 2-4 inches Diameter - Repair includes providing 1 hose 2 to 4 inches in diameter and less than 20 feet in length.$ - 0$ - 0$ - 0$ - 0$ - 0
Fuel hoses under 2 inches in diameter and less than 20 feet in length - Replacement.$ - 0$ - 0$ - 0$ - 0$ - 0
Gauges - Replace 1 Differential Pressure Gauge Replacement$ - 0$ - 0$ - 0$ - 0$ - 0
Gauges - Replace 1 Pressure or Pressure/Vacuum Gauges$ - 0$ - 0$ - 0$ - 0$ - 0
Ground Reel - Replace a single heavy duty Static Grounding reel to include 100 feet of 3/32" Nylon coated wire and a heavy duty ground clamp (MIL-C-83413/7).$ - 0$ - 0$ - 0$ - 0$ - 0
Hardware Replacement - Repair includes all bolts, nuts, washers, etc. for a flanged connection for piping ≤ 8" in diameter.$ - 0$ - 0$ - 0$ - 0$ - 0
Hose End Pressure Regulator. Includes Replacing 1 Hose End Pressure Regulator$ - 0$ - 0$ - 0$ - 0$ - 0
Load, Offload, and Refueling Nozzle Replacement$ - 0$ - 0$ - 0$ - 0$ - 0
Markings - Misc. System Components (Valves, Pumps, Meters, Hydrant Pit Covers, etc.). Repair Includes Providing Markings for 1 System Component.$ - 0$ - 0$ - 0$ - 0$ - 0
Markings - Pipe Markings. A single marking is defined as all required product identification and directional arrows along a minimum of 25 linear feet.$ - 0$ - 0$ - 0$ - 0$ - 0
Markings - Tank Markings - Tanks 420,000 Gallons and Under. 1 Repair includes all markings on tank required by UFC 3-460-01.$ - 0$ - 0$ - 0$ - 0$ - 0
Markings - Tank Markings - Tanks over 420,000 gallons. 1 Repair includes all markings on tank required by UFC 3-460-01.$ - 0$ - 0$ - 0$ - 0$ - 0
Hose and Hydrant System Nozzle / Hose Covers or Dust Caps. 1 Repair includes the hose end cover or dust caps for 1 hose.$ - 0$ - 0$ - 0$ - 0$ - 0
Pipe Support (Pipes 4" or Less) - PTFE (Teflon) Pipe Support Pads or Bearing Plates. Repair includes 1 PTFE pipe support or bearing plate.$ - 0$ - 0$ - 0$ - 0$ - 0
Pipe Support (Pipes > 4")- PTFE (Teflon) Pipe Support Pads or Bearing Plates. Repair includes 1 PTFE pipe support or bearing plate.$ - 0$ - 0$ - 0$ - 0$ - 0
Pipe Support (Pipes 4" or Less)- Misc. Hardware - Replace Missing/Corroded/Damaged Bolts or U-Bolts on Pipe Support System (1 Repair includes either 2 Plastic coated U-bolts to restrain pipe or 1 set of hardware to anchor pipe support to concrete or other foundation/substructure).$ - 0$ - 0$ - 0$ - 0$ - 0
Pipe Support (Pipes > 4") - Misc. Hardware - Replace Missing/Corroded/Damaged Bolts or U-Bolts on Pipe Support System (1 Repair includes either 2 Plastic coated U-bolts to restrain pipe or 1 set of hardware to anchor pipe support to concrete or other foundation/substructure).$ - 0$ - 0$ - 0$ - 0$ - 0
Signage - Repair includes 1 Metal Sign up to 4 SF in Area.$ - 0$ - 0$ - 0$ - 0$ - 0
Tank Chime sealant repair - 250 LF per Installation$ - 0$ - 0$ - 0$ - 0$ - 0
Valves, Check Valves (X ≤ 2 Inches). Repair includes replacement of 1 valve. (Carbon Steel)$ - 0$ - 0$ - 0$ - 0$ - 0
Valves, Check Valves (2 Inches < X ≤ 4 Inches). Repair includes replacement of 1 valve. (Carbon Steel)$ - 0$ - 0$ - 0$ - 0$ - 0
Valves, Check Valves (4 Inches < X ≤ 8 Inches). Repair includes replacement of 1 valve. (Carbon Steel)$ - 0$ - 0$ - 0$ - 0$ - 0
Valves, Diaphragm Control Valve (X ≤ 2 Inches). Repair includes rebuilding only of valve. (Carbon Steel or Stainless)$ - 0$ - 0$ - 0$ - 0$ - 0
Valves, Diaphragm Control Valve (2 Inches < X ≤ 4 Inches). Repair includes rebuilding only of valve. (Carbon Steel or Stainless)$ - 0$ - 0$ - 0$ - 0$ - 0
Valves, Double Block and Bleed Valve (2 Inches < X ≤ 4 Inches). Repair includes replacement of 1 valve. (Carbon Steel)$ - 0$ - 0$ - 0$ - 0$ - 0
Valves, Double Block and Bleed Valve (4 Inches < X ≤ 8 Inches). Repair includes replacement of 1 valve. (Carbon Steel)$ - 0$ - 0$ - 0$ - 0$ - 0
Valves, Manually Operated (ie Ball, Gate, Butterfly etc) (X ≤ 2 Inches). Repair includes replacement of 1 valve. (Carbon Steel)$ - 0$ - 0$ - 0$ - 0$ - 0
Valves, Manually Operated (ie Ball, Gate, Butterfly etc) (2 Inches < X ≤ 4 Inches). Repair includes replacement of 1 valve. (Carbon Steel)$ - 0$ - 0$ - 0$ - 0$ - 0
Valves, Manually Operated (ie Ball, Gate, Butterfly etc) (4 Inches < X ≤ 8 Inches). Repair includes replacement of 1 valve. (Carbon Steel).$ - 0$ - 0$ - 0$ - 0$ - 0
Valves, Manually Operated Plug (X ≤ 2 Inches). Repair includes replacement of 1 valve. (Carbon Steel)$ - 0$ - 0$ - 0$ - 0$ - 0
Valves, Manually Operated Plug (2 Inches < X ≤ 4 Inches). Repair includes replacement of 1 valve. (Carbon Steel)$ - 0$ - 0$ - 0$ - 0$ - 0
Valves, Manually Operated Plug (4 Inches < X ≤ 8 Inches). Repair includes replacement of 1 valve. (Carbon Steel).$ - 0$ - 0$ - 0$ - 0$ - 0
Valves, Pressure Relief Valves or Thermal Relief Valves. Repair includes replacement of Pressure or Thermal Relief Valve. (Carbon)$ - 0$ - 0$ - 0$ - 0$ - 0
Valves, Pressure Relief Valves or Thermal Relief Valves. Repair includes replacement of Pressure or Thermal Relief Valve. (Stainless Steel)$ - 0$ - 0$ - 0$ - 0$ - 0
Joint Sealant (Reference PWS 3.4.2.1) - ≤800 LF per Site
(17 Sites)$ - 0$ - 0$ - 0$ - 0$ - 0
Crack Repair (Reference PWS 3.4.2.1) - ≤800 LF per Site
(17 Sites)$ - 0$ - 0$ - 0$ - 0$ - 0
Touch-Up Coating Repair (Reference PWS 3.4.2.2) - 200 SF per Site
(17 Sites)$ - 0$ - 0$ - 0$ - 0$ - 0
CLIN X005 - OTHER DIRECT COSTS
SITEDLA SITE CODERPSUIDSERVICEBASE YEAROPT 1OPT 2OPT 3 (6MN PERIOD)6 MONTH EXT
TOTAL:$ - 0$ - 0$ - 0$ - 0$ - 0
Jacksonville IAP Site #1JVL2390AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Cape Canaveral AFS Site #1DBE1555AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Patrick AFBPAT3143AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Charleston AFB (ID 26) - Joint BaseCAF1579AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
DFSP CharlestonCHS1580AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Douglas MAP ANG (ID 146)DGL1661AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Dobbins ARB (ID 192)DOB1660AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Glynco ANG StationJAS2124AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Joint Base Charleston NWSJBC213AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Moody AFBMDY3020AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
McEntire ANG (ID 158)MNT2793AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Robins AFBRBA3219AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Savannah ANG (IAP ID 107)SAG3358AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Savannah/Hilton Head IAP Site #3SHH17105AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Shaw AFB (ID 55)SHW3269AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Seymour Johnson AFB (ID 56)SMJ3268AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Stanly County AirportWEF3312AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
CLIN X006 - IRREGULAR PREVENTIVE MAINTENANCE
SITEDLA Site CodeRPSUIDSERVICEBASE YEAROPT 1OPT 2OPT 3 (6MN PERIOD)6 MONTH EXT
TOTAL:$ - 0$ - 0$ - 0$ - 0$ - 0
Jacksonville IAP Site #1JVL2390AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Cape Canaveral AFS Site #1DBE1555AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Patrick AFBPAT3143AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Charleston AFB (ID 26) - Joint BaseCAF1579AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
DFSP CharlestonCHS1580AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Douglas MAP ANG (ID 146)DGL1661AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Dobbins ARB (ID 192)DOB1660AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Glynco ANG StationJAS2124AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Joint Base Charleston NWSJBC213AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Moody AFBMDY3020AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
McEntire ANG (ID 158)MNT2793AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Robins AFBRBA3219AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Savannah ANG (IAP ID 107)SAG3358AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Savannah/Hilton Head IAP Site #3SHH17105AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Shaw AFB (ID 55)SHW3269AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Seymour Johnson AFB (ID 56)SMJ3268AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0
Stanly County AirportWEF3312AIR FORCE$ - 0$ - 0$ - 0$ - 0$ - 0

&A

CUI

CLIN X001 PM Qrtly INSTRUCTIONS - Complete the provided fields in GREEN. The worksheet is automated and will populate pricing for option years following the Base Year. Note the notice to proceed date for each site and propose according to that start date. After the notice to proceed date, the period of performance date for the site will align with the contract period of performance. Grayed out cells indicate no maintenance activity and should not be calculated (Refer to Appendix I and J). Please refer to the PWS section 1.5.0 Personnel Requirements for key personnel. These personnel are also provided within the Direct Labor Tab.

NOTE – “FAR 52.217-8 Option to Extend Services if exercised shall not exceed the last option year’s rates proposed by the offeror and shall reflect the appropriate level of effort for service activities in that period. The government reserves the right to exercise the “6-month” extension at the end of any ordering period which shall be subject to price adjustments that are commensurate with the appropriate level of effort and in accordance with the rates of the incumbent ordering period by bilateral modification.”

Escalation Rate:0%
CLIN 0001 - QUARTERLY PREVENTIVE MAINTENANCE
KEY PERSONNEL
SITESSERVICETotal
5AIR FORCE$ - 0
PREVENETIVE MAINTENANCE
SITE NAMEDLA SITE CODERPSUIDNOTICE TO PROCEED DATESERVICETOTAL
Jacksonville IAP Site #1JVL239014-Feb-26AIR FORCE$ - 0
Cape Canaveral AFS Site #1DBE155514-Feb-26AIR FORCE
Patrick AFBPAT314314-Feb-26AIR FORCE
Charleston AFB (ID 26) - Joint BaseCAF157914-Feb-26AIR FORCE
DFSP CharlestonCHS158014-Feb-26AIR FORCE$ - 0
Douglas MAP ANG (ID 146)DGL166114-Feb-26AIR FORCE
Dobbins ARB (ID 192)DOB166014-Feb-26AIR FORCE
Glynco ANG StationJAS212414-Feb-26AIR FORCE
Joint Base Charleston NWSJBC21314-Feb-26AIR FORCE$ - 0
Moody AFBMDY302014-Feb-26AIR FORCE$ - 0
McEntire ANG (ID 158)MNT279314-Feb-26AIR FORCE
Robins AFBRBA321914-Feb-26AIR FORCE$ - 0
Savannah ANG (IAP ID 107)SAG335814-Feb-26AIR FORCE
Savannah/Hilton Head IAP Site #3SHH1710514-Feb-26AIR FORCE
Shaw AFB (ID 55)SHW326914-Feb-26AIR FORCE
Seymour Johnson AFB (ID 56)SMJ326814-Feb-26AIR FORCE
Stanly County AirportWEF331214-Feb-26AIR FORCE
TOTALS:$ - 0
CLIN 1001 - QUARTERLY PREVENTIVE MAINTENANCE
KEY PERSONNEL
SITESSERVICETotal
5AIR FORCE$ - 0
PREVENTIVE MAINTENANCE
SITE NAMEDLA SITE CODERPSUIDNOTICE TO PROCEED DATESERVICETOTAL
Jacksonville IAP Site #1JVL239014-Feb-27AIR FORCE$ - 0
Cape Canaveral AFS Site #1DBE155514-Feb-27AIR FORCE
Patrick AFBPAT314314-Feb-27AIR FORCE
Charleston AFB (ID 26) - Joint BaseCAF157914-Feb-27AIR FORCE
DFSP CharlestonCHS158014-Feb-27AIR FORCE$ - 0
Douglas MAP ANG (ID 146)DGL166114-Feb-27AIR FORCE
Dobbins ARB (ID 192)DOB166014-Feb-27AIR FORCE
Glynco ANG StationJAS212414-Feb-27AIR FORCE
Joint Base Charleston NWSJBC21314-Feb-27AIR FORCE$ - 0
Moody AFBMDY302014-Feb-27AIR FORCE$ - 0
McEntire ANG (ID 158)MNT279314-Feb-27AIR FORCE
Robins AFBRBA321914-Feb-27AIR FORCE$ - 0
Savannah ANG (IAP ID 107)SAG335814-Feb-27AIR FORCE
Savannah/Hilton Head IAP Site #3SHH1710514-Feb-27AIR FORCE
Shaw AFB (ID 55)SHW326914-Feb-27AIR FORCE
Seymour Johnson AFB (ID 56)SMJ326814-Feb-27AIR FORCE
Stanly County AirportWEF331214-Feb-27AIR FORCE
TOTALS:$ - 0
CLIN 2001 - QUARTERLY PREVENTIVE MAINTENANCE
KEY PERSONNEL
SITESSERVICETotal
5AIR FORCE$ - 0
PREVENTIVE MAINTENANCE
SITE NAMEDLA SITE CODERPSUIDNOTICE TO PROCEED DATESERVICETOTAL
Jacksonville IAP Site #1JVL239014-Feb-28AIR FORCE$ - 0
Cape Canaveral AFS Site #1DBE155514-Feb-28AIR FORCE
Patrick AFBPAT314314-Feb-28AIR FORCE
Charleston AFB (ID 26) - Joint BaseCAF157914-Feb-28AIR FORCE
DFSP CharlestonCHS158014-Feb-28AIR FORCE$ - 0
Douglas MAP ANG (ID 146)DGL166114-Feb-28AIR FORCE
Dobbins ARB (ID 192)DOB166014-Feb-28AIR FORCE
Glynco ANG StationJAS212414-Feb-28AIR FORCE
Joint Base Charleston NWSJBC21314-Feb-28AIR FORCE$ - 0
Moody AFBMDY302014-Feb-28AIR FORCE$ - 0
McEntire ANG (ID 158)MNT279314-Feb-28AIR FORCE
Robins AFBRBA321914-Feb-28AIR FORCE$ - 0
Savannah ANG (IAP ID 107)SAG335814-Feb-28AIR FORCE
Savannah/Hilton Head IAP Site #3SHH1710514-Feb-28AIR FORCE
Shaw AFB (ID 55)SHW326914-Feb-28AIR FORCE
Seymour Johnson AFB (ID 56)SMJ326814-Feb-28AIR FORCE
Stanly County AirportWEF331214-Feb-28AIR FORCE
TOTALS:$ - 0
CLIN 3001 (6MN OPTION PERIOD) - QUARTERLY PREVENTIVE MAINTENANCE
KEY PERSONNEL
SITESSERVICETotal
5AIR FORCE$ - 0
PREVENTIVE MAINTENANCE
SITE NAMEDLA SITE CODERPSUIDNOTICE TO PROCEED DATESERVICETOTAL
Jacksonville IAP Site #1JVL239014-Feb-29AIR FORCE$ - 0
Cape Canaveral AFS Site #1DBE155514-Feb-29AIR FORCE
Patrick AFBPAT314314-Feb-29AIR FORCE
Charleston AFB (ID 26) - Joint BaseCAF157914-Feb-29AIR FORCE
DFSP CharlestonCHS158014-Feb-29AIR FORCE$ - 0
Douglas MAP ANG (ID 146)DGL166114-Feb-29AIR FORCE
Dobbins ARB (ID 192)DOB166014-Feb-29AIR FORCE
Glynco ANG StationJAS212414-Feb-29AIR FORCE
Joint Base Charleston NWSJBC21314-Feb-29AIR FORCE$ - 0
Moody AFBMDY302014-Feb-29AIR FORCE$ - 0
McEntire ANG (ID 158)MNT279314-Feb-29AIR FORCE
Robins AFBRBA321914-Feb-29AIR FORCE$ - 0
Savannah ANG (IAP ID 107)SAG335814-Feb-29AIR FORCE
Savannah/Hilton Head IAP Site #3SHH1710514-Feb-29AIR FORCE
Shaw AFB (ID 55)SHW326914-Feb-29AIR FORCE
Seymour Johnson AFB (ID 56)SMJ326814-Feb-29AIR FORCE
Stanly County AirportWEF331214-Feb-29AIR FORCE
TOTALS:$ - 0
CLIN 4001 (6 MN EXTENSION) - QUARTERLY PREVENTIVE MAINTENANCE
KEY PERSONNEL
SITESSERVICETotal
5AIR FORCE$ - 0
PREVENTIVE MAINTENANCE
SITE NAMEDLA SITE CODERPSUIDNOTICE TO PROCEED DATESERVICETOTAL
Jacksonville IAP Site #1JVL239014-Aug-29AIR FORCE$ - 0
Cape Canaveral AFS Site #1DBE155514-Aug-29AIR FORCE
Patrick AFBPAT314314-Aug-29AIR FORCE
Charleston AFB (ID 26) - Joint BaseCAF157914-Aug-29AIR FORCE
DFSP CharlestonCHS158014-Aug-29AIR FORCE$ - 0
Douglas MAP ANG (ID 146)DGL166114-Aug-29AIR FORCE
Dobbins ARB (ID 192)DOB166014-Aug-29AIR FORCE
Glynco ANG StationJAS212414-Aug-29AIR FORCE
Joint Base Charleston NWSJBC21314-Aug-29AIR FORCE$ - 0
Moody AFBMDY302014-Aug-29AIR FORCE$ - 0
McEntire ANG (ID 158)MNT279314-Aug-29AIR FORCE
Robins AFBRBA321914-Aug-29AIR FORCE$ - 0
Savannah ANG (IAP ID 107)SAG335814-Aug-29AIR FORCE
Savannah/Hilton Head IAP Site #3SHH1710514-Aug-29AIR FORCE
Shaw AFB (ID 55)SHW326914-Aug-29AIR FORCE
Seymour Johnson AFB (ID 56)SMJ326814-Aug-29AIR FORCE
Stanly County AirportWEF331214-Aug-29AIR FORCE
TOTALS:$ - 0

&A

CUI

CLIN X002 PM SemiAnnual INSTRUCTIONS - Complete the provided fields in GREEN. The worksheet is automated and will populate pricing for option years following the Base Year. Note the notice to proceed date for each site and propose according to that start date. After the notice to proceed date, the period of performance date for the site will align with the contract period of performance. Please note Site Names with * indicate sites that ONLY receive semi-annual meter calibration (Refer to Appendix I and J). Grayed out cells indicate no maintenance activity and should not be calculated (Refer to Appendix I and J). Pricing for Key Personnel should only include fully dedicated personnel as defined by PWS section 1.5.0 Personnel Requirements. These personnel are also provided within the Direct Labor Tab.

NOTE – “FAR 52.217-8 Option to Extend Services if exercised shall not exceed the last option year’s rates proposed by the offeror and shall reflect the appropriate level of effort for service activities in that period. The government reserves the right to exercise the “6-month” extension at the end of any ordering period which shall be subject to price adjustments that are commensurate with the appropriate level of effort and in accordance with the rates of the incumbent ordering period by bilateral modification.”

Escalation Rate:0%
CLIN 0002 - SEMI-ANNUAL PREVENTIVE MAINTENANCE
KEY PERSONNEL
SITESSERVICETotal
Key Personnel10AIR FORCE$ - 0
PREVENTIVE MAINTENANCE
SITE NAMEDLA SITE CODERPSUIDNOTICE TO PROCEED DATESERVICETOTAL
Jacksonville IAP Site #1JVL239014-Feb-26AIR FORCE$ - 0
Cape Canaveral AFS Site #1DBE155514-Feb-26AIR FORCE
Patrick AFBPAT314314-Feb-26AIR FORCE
Charleston AFB (ID 26) - Joint BaseCAF157914-Feb-26AIR FORCE
DFSP CharlestonCHS158014-Feb-26AIR FORCE$ - 0
Douglas MAP ANG (ID 146)*DGL166114-Feb-26AIR FORCE$ - 0
Dobbins ARB (ID 192)*DOB166014-Feb-26AIR FORCE$ - 0
Glynco ANG StationJAS212414-Feb-26AIR FORCE
Joint Base Charleston NWSJBC21314-Feb-26AIR FORCE$ - 0
Moody AFBMDY302014-Feb-26AIR FORCE$ - 0
McEntire ANG (ID 158)*MNT279314-Feb-26AIR FORCE$ - 0
Robins AFBRBA321914-Feb-26AIR FORCE$ - 0
Savannah ANG (IAP ID 107) *SAG335814-Feb-26AIR FORCE$ - 0
Savannah/Hilton Head IAP Site #3SHH1710514-Feb-26AIR FORCE
Shaw AFB (ID 55)SHW326914-Feb-26AIR FORCE
Seymour Johnson AFB (ID 56) *SMJ326814-Feb-26AIR FORCE$ - 0
Stanly County AirportWEF331214-Feb-26AIR FORCE
TOTALS:$ - 0
CLIN 1002 - SEMI-ANNUAL PREVENTIVE MAINTENANCE
KEY PERSONNEL
SITESSERVICETotal
Key Personnel10AIR FORCE$ - 0
PREVENTIVE MAINTENANCE
SITE NAMEDLA SITE CODERPSUIDNOTICE TO PROCEED DATESERVICETOTAL
Jacksonville IAP Site #1JVL239014-Feb-27AIR FORCE$ - 0
Cape Canaveral AFS Site #1DBE155514-Feb-27AIR FORCE
Patrick AFBPAT314314-Feb-27AIR FORCE
Charleston AFB (ID 26) - Joint BaseCAF157914-Feb-27AIR FORCE
DFSP CharlestonCHS158014-Feb-27AIR FORCE$ - 0
Douglas MAP ANG (ID 146)*DGL166114-Feb-27AIR FORCE$ - 0
Dobbins ARB (ID 192)*DOB166014-Feb-27AIR FORCE$ - 0
Glynco ANG StationJAS212414-Feb-27AIR FORCE
Joint Base Charleston NWSJBC21314-Feb-27AIR FORCE$ - 0
Moody AFBMDY302014-Feb-27AIR FORCE$ - 0
McEntire ANG (ID 158)*MNT279314-Feb-27AIR FORCE$ - 0
Robins AFBRBA321914-Feb-27AIR FORCE$ - 0
Savannah ANG (IAP ID 107) *SAG335814-Feb-27AIR FORCE$ - 0
Savannah/Hilton Head IAP Site #3SHH1710514-Feb-27AIR FORCE
Shaw AFB (ID 55)SHW326914-Feb-27AIR FORCE
Seymour Johnson AFB (ID 56) *SMJ326814-Feb-27AIR FORCE$ - 0
Stanly County AirportWEF331214-Feb-27AIR FORCE
TOTALS:$ - 0
CLIN 2002 - SEMI-ANNUAL PREVENTIVE MAINTENANCE
KEY PERSONNEL
SITESSERVICETotal
Key Personnel10AIR FORCE$ - 0
PREVENTIVE MAINTENANCE
SITE NAMEDLA SITE CODERPSUIDNOTICE TO PROCEED DATESERVICETOTAL
Jacksonville IAP Site #1JVL239015-Feb-28AIR FORCE$ - 0
Cape Canaveral AFS Site #1DBE155515-Feb-28AIR FORCE
Patrick AFBPAT314315-Feb-28AIR FORCE
Charleston AFB (ID 26) - Joint BaseCAF157915-Feb-28AIR FORCE
DFSP CharlestonCHS158015-Feb-28AIR FORCE$ - 0
Douglas MAP ANG (ID 146)*DGL166115-Feb-28AIR FORCE$ - 0
Dobbins ARB (ID 192)*DOB166015-Feb-28AIR FORCE$ - 0
Glynco ANG StationJAS212415-Feb-28AIR FORCE
Joint Base Charleston NWSJBC21315-Feb-28AIR FORCE$ - 0
Moody AFBMDY302015-Feb-28AIR FORCE$ - 0
McEntire ANG (ID 158)*MNT279315-Feb-28AIR FORCE$ - 0
Robins AFBRBA321915-Feb-28AIR FORCE$ - 0
Savannah ANG (IAP ID 107) *SAG335815-Feb-28AIR FORCE$ - 0
Savannah/Hilton Head IAP Site #3SHH1710515-Feb-28AIR FORCE
Shaw AFB (ID 55)SHW326915-Feb-28AIR FORCE
Seymour Johnson AFB (ID 56) *SMJ326815-Feb-28AIR FORCE$ - 0
Stanly County AirportWEF331215-Feb-28AIR FORCE
TOTALS:$ - 0
CLIN 3002 (6 MN OPTION PERIOD) - SEMI-ANNUAL PREVENTIVE MAINTENANCE
KEY PERSONNEL
SITESSERVICETotal
Key Personnel10AIR FORCE$ - 0
PREVENTIVE MAINTENANCE
SITE NAMEDLA SITE CODERPSUIDNOTICE TO PROCEED DATESERVICETOTAL
Jacksonville IAP Site #1JVL239014-Feb-29AIR FORCE$ - 0
Cape Canaveral AFS Site #1DBE155514-Feb-29AIR FORCE
Patrick AFBPAT314314-Feb-29AIR FORCE
Charleston AFB (ID 26) - Joint BaseCAF157914-Feb-29AIR FORCE
DFSP CharlestonCHS158014-Feb-29AIR FORCE$ - 0
Douglas MAP ANG (ID 146)*DGL166114-Feb-29AIR FORCE$ - 0
Dobbins ARB (ID 192)*DOB166014-Feb-29AIR FORCE$ - 0
Glynco ANG StationJAS212414-Feb-29AIR FORCE
Joint Base Charleston NWSJBC21314-Feb-29AIR FORCE$ - 0
Moody AFBMDY302014-Feb-29AIR FORCE$ - 0
McEntire ANG (ID 158)*MNT279314-Feb-29AIR FORCE$ - 0
Robins AFBRBA321914-Feb-29AIR FORCE$ - 0
Savannah ANG (IAP ID 107) *SAG335814-Feb-29AIR FORCE$ - 0
Savannah/Hilton Head IAP Site #3SHH1710514-Feb-29AIR FORCE
Shaw AFB (ID 55)SHW326914-Feb-29AIR FORCE
Seymour Johnson AFB (ID 56) *SMJ326814-Feb-29AIR FORCE$ - 0
Stanly County AirportWEF331214-Feb-29AIR FORCE
TOTALS:$ - 0
CLIN 4002 (6 MN EXTENSION) - SEMI-ANNUAL PREVENTIVE MAINTENANCE
KEY PERSONNEL
SITESSERVICETotal
Key Personnel10AIR FORCE$ - 0
PREVENTIVE MAINTENANCE
SITE NAMEDLA SITE CODERPSUIDNOTICE TO PROCEED DATESERVICETOTAL
Jacksonville IAP Site #1JVL239014-Aug-29AIR FORCE$ - 0
Cape Canaveral AFS Site #1DBE155514-Aug-29AIR FORCE
Patrick AFBPAT314314-Aug-29AIR FORCE
Charleston AFB (ID 26) - Joint BaseCAF157914-Aug-29AIR FORCE
DFSP CharlestonCHS158014-Aug-29AIR FORCE$ - 0
Douglas MAP ANG (ID 146)*DGL166114-Aug-29AIR FORCE$ - 0
Dobbins ARB (ID 192)*DOB166014-Aug-29AIR FORCE$ - 0
Glynco ANG StationJAS212414-Aug-29AIR FORCE
Joint Base Charleston NWSJBC21314-Aug-29AIR FORCE$ - 0
Moody AFBMDY302014-Aug-29AIR FORCE$ - 0
McEntire ANG (ID 158)*MNT279314-Aug-29AIR FORCE$ - 0
Robins AFBRBA321914-Aug-29AIR FORCE$ - 0
Savannah ANG (IAP ID 107) *SAG335814-Aug-29AIR FORCE$ - 0
Savannah/Hilton Head IAP Site #3SHH1710514-Aug-29AIR FORCE
Shaw AFB (ID 55)SHW326914-Aug-29AIR FORCE
Seymour Johnson AFB (ID 56) *SMJ326814-Aug-29AIR FORCE$ - 0
Stanly County AirportWEF331214-Aug-29AIR FORCE
TOTALS:$ - 0

&A

CUI

CLIN X003 PM Annual INSTRUCTIONS - Complete the provided fields in GREEN. The worksheet is automated and will populate pricing for option years following the Base Year. Note the notice to proceed date for each site and propose according to that start date. After the notice to proceed date, the period of performance date for the site will align with the contract period of performance. Grayed out cells indicate no maintenance activity and should not be calculated (Refer to Appendix I and J). Pricing for Key Personnel should only include fully dedicated personnel as defined by PWS section 1.5.0 Personnel Requirements. These personnel are also provided within the Direct Labor Tab.

NOTE – “FAR 52.217-8 Option to Extend Services if exercised shall not exceed the last option year’s rates proposed by the offeror and shall reflect the appropriate level of effort for service activities in that period. . The government reserves the right to exercise the “6-month” extension at the end of any ordering period which shall be subject to price adjustments that are commensurate with the appropriate level of effort and in accordance with the rates of the incumbent ordering period by bilateral modification.” For Annual events scheduled to occur in the 6-month extension, event pricing shall not exceed the previous Option Year. Annual events executed within the 6-month extension shall be performed in entirety.

Escalation Rate:0%
CLIN 0003 - ANNUAL PREVENTIVE MAINTENANCE
KEY PERSONNEL
SITESSERVICETotal
Key Personnel17AIR FORCE$ - 0
PREVENTATIVE MAINTENANCE
SITE NAMEDLA SITE CODERPSUIDNOTICE TO PROCEED DATESERVICETOTAL
Jacksonville IAP Site #1JVL239014-Feb-26AIR FORCE$ - 0
Cape Canaveral AFS Site #1DBE155514-Feb-26AIR FORCE$ - 0
Patrick AFBPAT314314-Feb-26AIR FORCE$ - 0
Charleston AFB (ID 26) - Joint BaseCAF157914-Feb-26AIR FORCE$ - 0
DFSP CharlestonCHS158014-Feb-26AIR FORCE$ - 0
Douglas MAP ANG (ID 146)DGL166114-Feb-26AIR FORCE$ - 0
Dobbins ARB (ID 192)DOB166014-Feb-26AIR FORCE$ - 0
Glynco ANG StationJAS212414-Feb-26AIR FORCE$ - 0
Joint Base Charleston NWSJBC21314-Feb-26AIR FORCE$ - 0
Moody AFBMDY302014-Feb-26AIR FORCE$ - 0
McEntire ANG (ID 158)MNT279314-Feb-26AIR FORCE$ - 0
Robins AFBRBA321914-Feb-26AIR FORCE$ - 0
Savannah ANG (IAP ID 107)SAG335814-Feb-26AIR FORCE$ - 0
Savannah/Hilton Head IAP Site #3SHH1710514-Feb-26AIR FORCE$ - 0
Shaw AFB (ID 55)SHW326914-Feb-26AIR FORCE$ - 0
Seymour Johnson AFB (ID 56)SMJ326814-Feb-26AIR FORCE$ - 0
Stanly County AirportWEF331214-Feb-26AIR FORCE$ - 0
TOTALS:$ - 0
CLIN 1003 - ANNUAL PREVENTIVE MAINTENANCE
KEY PERSONNEL
SITESSERVICETotal
Key Personnel17AIR FORCE$ - 0
PREVENTIVE MAINTENANCE
SITE NAMEDLA SITE CODERPSUIDNOTICE TO PROCEED DATESERVICETOTAL
Jacksonville IAP Site #1JVL239014-Feb-27AIR FORCE$ - 0
Cape Canaveral AFS Site #1DBE155514-Feb-27AIR FORCE$ - 0
Patrick AFBPAT314314-Feb-27AIR FORCE$ - 0
Charleston AFB (ID 26) - Joint BaseCAF157914-Feb-27AIR FORCE$ - 0
DFSP CharlestonCHS158014-Feb-27AIR FORCE$ - 0
Douglas MAP ANG (ID 146)DGL166114-Feb-27AIR FORCE$ - 0
Dobbins ARB (ID 192)DOB166014-Feb-27AIR FORCE$ - 0
Glynco ANG StationJAS212414-Feb-27AIR FORCE$ - 0
Joint Base Charleston NWSJBC21314-Feb-27AIR FORCE$ - 0
Moody AFBMDY302014-Feb-27AIR FORCE$ - 0
McEntire ANG (ID 158)MNT279314-Feb-27AIR FORCE$ - 0
Robins AFBRBA321914-Feb-27AIR FORCE$ - 0
Savannah ANG (IAP ID 107)SAG335814-Feb-27AIR FORCE$ - 0
Savannah/Hilton Head IAP Site #3SHH1710514-Feb-27AIR FORCE$ - 0
Shaw AFB (ID 55)SHW326914-Feb-27AIR FORCE$ - 0
Seymour Johnson AFB (ID 56)SMJ326814-Feb-27AIR FORCE$ - 0
Stanly County AirportWEF331214-Feb-27AIR FORCE$ - 0
TOTALS:$ - 0
CLIN 2003 - ANNUAL PREVENTIVE MAINTENANCE
KEY PERSONNEL
SITESSERVICETotal
Key Personnel17AIR FORCE$ - 0
PREVENTIVE MAINTENANCE
SITE NAMEDLA SITE CODERPSUIDNOTICE TO PROCEED DATESERVICETOTAL
Jacksonville IAP Site #1JVL239014-Feb-28AIR FORCE$ - 0
Cape Canaveral AFS Site #1DBE155514-Feb-28AIR FORCE$ - 0
Patrick AFBPAT314314-Feb-28AIR FORCE$ - 0
Charleston AFB (ID 26) - Joint BaseCAF157914-Feb-28AIR FORCE$ - 0
DFSP CharlestonCHS158014-Feb-28AIR FORCE$ - 0
Douglas MAP ANG (ID 146)DGL166114-Feb-28AIR FORCE$ - 0
Dobbins ARB (ID 192)DOB166014-Feb-28AIR FORCE$ - 0
Glynco ANG StationJAS212414-Feb-28AIR FORCE$ - 0
Joint Base Charleston NWSJBC21314-Feb-28AIR FORCE$ - 0
Moody AFBMDY302014-Feb-28AIR FORCE$ - 0
McEntire ANG (ID 158)MNT279314-Feb-28AIR FORCE$ - 0
Robins AFBRBA321914-Feb-28AIR FORCE$ - 0
Savannah ANG (IAP ID 107)SAG335814-Feb-28AIR FORCE$ - 0
Savannah/Hilton Head IAP Site #3SHH1710514-Feb-28AIR FORCE$ - 0
Shaw AFB (ID 55)SHW326914-Feb-28AIR FORCE$ - 0
Seymour Johnson AFB (ID 56)SMJ326814-Feb-28AIR FORCE$ - 0
Stanly County AirportWEF331214-Feb-28AIR FORCE$ - 0
TOTALS:$ - 0
CLIN 3003 (6 MN OPTION PERIOD) - ANNUAL PREVENTIVE MAINTENANCE
KEY PERSONNEL
SITESSERVICETotal
Key Personnel9AIR FORCE$ - 0
PREVENTIVE MAINTENANCE
SITE NAMEDLA SITE CODERPSUIDNOTICE TO PROCEED DATESERVICETOTAL
Jacksonville IAP Site #1JVL239013-Feb-29AIR FORCE$ - 0
Cape Canaveral AFS Site #1DBE155513-Feb-29AIR FORCE$ - 0
Patrick AFBPAT314313-Feb-29AIR FORCE$ - 0
Charleston AFB (ID 26) - Joint BaseCAF157913-Feb-29AIR FORCE
DFSP CharlestonCHS158013-Feb-29AIR FORCE
Douglas MAP ANG (ID 146)DGL166113-Feb-29AIR FORCE
Dobbins ARB (ID 192)DOB166013-Feb-29AIR FORCE$ - 0
Glynco ANG StationJAS212413-Feb-29AIR FORCE
Joint Base Charleston NWSJBC21313-Feb-29AIR FORCE$ - 0
Moody AFBMDY302013-Feb-29AIR FORCE
McEntire ANG (ID 158)MNT279313-Feb-29AIR FORCE$ - 0
Robins AFBRBA321913-Feb-29AIR FORCE$ - 0
Savannah ANG (IAP ID 107)SAG335813-Feb-29AIR FORCE
Savannah/Hilton Head IAP Site #3SHH1710513-Feb-29AIR FORCE
Shaw AFB (ID 55)SHW326913-Feb-29AIR FORCE$ - 0
Seymour Johnson AFB (ID 56)SMJ326813-Feb-29AIR FORCE$ - 0
Stanly County AirportWEF331213-Feb-29AIR FORCE
TOTALS:$ - 0
CLIN 4003 (6 MN EXTENSION) - ANNUAL PREVENTIVE MAINTENANCE
KEY PERSONNEL
SITESSERVICETotal
Key Personnel8AIR FORCE$ - 0
PREVENTIVE MAINTENANCE
SITE NAMEDLA SITE CODERPSUIDNOTICE TO PROCEED DATESERVICETOTAL
Jacksonville IAP Site #1JVL239013-Aug-29AIR FORCE
Cape Canaveral AFS Site #1DBE155513-Aug-29AIR FORCE
Patrick AFBPAT314313-Aug-29AIR FORCE
Charleston AFB (ID 26) - Joint BaseCAF157913-Aug-29AIR FORCE$ - 0
DFSP CharlestonCHS158013-Aug-29AIR FORCE$ - 0
Douglas MAP ANG (ID 146)DGL166113-Aug-29AIR FORCE$ - 0
Dobbins ARB (ID 192)DOB166013-Aug-29AIR FORCE
Glynco ANG StationJAS212413-Aug-29AIR FORCE$ - 0
Joint Base Charleston NWSJBC21313-Aug-29AIR FORCE
Moody AFBMDY302013-Aug-29AIR FORCE$ - 0
McEntire ANG (ID 158)MNT279313-Aug-29AIR FORCE
Robins AFBRBA321913-Aug-29AIR FORCE
Savannah ANG (IAP ID 107)SAG335813-Aug-29AIR FORCE$ - 0
Savannah/Hilton Head IAP Site #3SHH1710513-Aug-29AIR FORCE$ - 0
Shaw AFB (ID 55)SHW326913-Aug-29AIR FORCE
Seymour Johnson AFB (ID 56)SMJ326813-Aug-29AIR FORCE
Stanly County AirportWEF331213-Aug-29AIR FORCE$ - 0
TOTALS:$ - 0

&A

CUI

CLIN X004 CM NTE

NSTRUCTIONS - DO NOT PRICE .The values for CLIN 4 Corrective Maintenance are provided by the Government as an estimate of Corrective Maintenance to be performed in accordance with PWS Sections 3.4 and 3.5. This amount may increase or decrease depending on the needs that arise for unscheduled services. The Contractor is not guaranteed nor entitled to the full amount as estimated.
Corrective Maintenance (Estimated)
CLIN X004 (TOTAL)$52,153,302.00
Binding Service Order Markups
MarkupsValue
Profit (%)0.0%
SO Indirect Markup (Supporting Narrative Required) (%)0.0%
Total Service Order Fee (%)0.0%
Emergency Service Order Indirect Rate ($)$0.00

&A

CUI

Service Order Fee Instructions:

In the box below, (1) Define the proposed profit and other indirect markup pecentage for service orders per PWS Appendix A, Section 2.10.2. (2) Explain what markups are included in the Indirect SO Markup (Ex G&A, Overhead) and (3) Provide enough information to allow for the Contracting Officer to determine fair and reasonableness. NOTE:All administrative, professional, and supervisory oversight required for SO execution, beyond PWS key personnel included in the FFP CLINs (CLINS 1, 2, 3, 6), are to be included in your service order fee. The Service Order Fee shall NOT include cost for work plan development or emergency service order fee per PWS Appendix A, Section 2.10.2.

A) All other pricing information shall be included within the offerors Basis of Estimate (BOE).

B) Do not provide duplicated markups within fully burdened labor rates and Service Order Fee. If there are special circumstances, provide an explanation.

C) The emergency service order fee shall be a flat rate fee to cover any costs associated with an emergency service order that are above and beyond what is generally covered in a routine service order. Pricing shall be in acordance with PWS Appendix A Section 2.2 Emergency Service Orders.

Service Order Fee Explanation:

CM Price List

INSTRUCTIONS- Complete the provided fields in GREEN. The Contractor shall provide unit prices for each category listed. This unit price shall include all costs associated with the repair. Pricing will be firm fixed price and funded by CLIN 4 Corrective Maintenance per PWS 3.4.2 and Appendix H -Corrective Measures Incidental to Maintentance.
Escalation Rate:0%
CORRECTIVE MAINTENANCE PRICE LIST
BASE YEAR - CORRECTIVE MAINTENANCE
CATEGORYREPAIRS PER YEAR (EST FOR EVAL PURPOSES ONLY)UNIT PRICETOTAL
Air eliminators2$ - 0$ - 0
Bollards - Repair includes Prep and Recoat one Bollard up to 6" diameter and 48" tall or provide plastic cover for same. Applicable markings are included as part of repair.40$ - 0$ - 0
Deadman (Hydraulic) - Includes replacement of Deadman Handle and Cord/Hose.2$ - 0$ - 0
Deadman (Electronic) - Includes replacement of Deadman Handle and Cord/Hose.2$ - 0$ - 0
Dispenser Breakaway Connections - Includes Replacement of 1 Breakaway for Hoses ≤ 2".10$ - 0$ - 0
Dispenser Hose Retractors - Includes Replacement of 1 Retractor ≤ 10' in length.10$ - 0$ - 0
Dispenser Hose Swivels - Includes Replacement of 1 Swivel for Hoses ≤ 2".10$ - 0$ - 0
Dispenser Nozzles - Includes Replacement of 1 Dispenser Nozzle for Hoses ≤ 2".10$ - 0$ - 0
Emergency Fuel Shutoff (EFSO) Pushbutton Station - Includes Replacement and Wiring of Emergency Shuttoff Pushbutton Switch and Cover. Does not include troubleshooting or replacing wiring between EFSO Pushbutton and control panel.3$ - 0$ - 0
Flange Isolation Kit - 1 Repair includes complete isolation kit for a flanged connection (Gasket, Sleeves, Insulating Washers, etc.) for up to 8" piping.2$ - 0$ - 0
Flow Indicator Sight Glass Replacement3$ - 0$ - 0
Fuel Hoses 2-4 inches Diameter - Repair includes providing 1 hose 2 to 4 inches in diameter and less than 20 feet in length.3$ - 0$ - 0
Fuel hoses under 2 inches in diameter and less than 20 feet in length - Replacement.15$ - 0$ - 0
Gauges - Replace 1 Differential Pressure Gauge Replacement2$ - 0$ - 0
Gauges - Replace 1 Pressure or Pressure/Vacuum Gauges10$ - 0$ - 0
Ground Reel - Replace a single heavy duty Static Grounding reel to include 100 feet of 3/32" Nylon coated wire and a heavy duty ground clamp (MIL-C-83413/7).4$ - 0$ - 0
Hardware Replacement - Repair includes all bolts, nuts, washers, etc. for a flanged connection for piping ≤ 8" in diameter.50$ - 0$ - 0
Hose End Pressure Regulator. Includes Replacing 1 Hose End Pressure Regulator2$ - 0$ - 0
Load, Offload, and Refueling Nozzle Replacement2$ - 0$ - 0
Markings - Misc. System Components (Valves, Pumps, Meters, Hydrant Pit Covers, etc.). Repair Includes Providing Markings for 1 System Component.6$ - 0$ - 0
Markings - Pipe Markings. A single marking is defined as all required product identification and directional arrows along a minimum of 25 linear feet.10$ - 0$ - 0
Markings - Tank Markings - Tanks 420,000 Gallons and Under. 1 Repair includes all markings on tank required by UFC 3-460-01.10$ - 0$ - 0
Markings - Tank Markings - Tanks over 420,000 gallons. 1 Repair includes all markings on tank required by UFC 3-460-01.4$ - 0$ - 0
Hose and Hydrant System Nozzle / Hose Covers or Dust Caps. 1 Repair includes the hose end cover or dust caps for 1 hose.10$ - 0$ - 0
Pipe Support (Pipes 4" or Less) - PTFE (Teflon) Pipe Support Pads or Bearing Plates. Repair includes 1 PTFE pipe support or bearing plate.15$ - 0$ - 0
Pipe Support (Pipes > 4")- PTFE (Teflon) Pipe Support Pads or Bearing Plates. Repair includes 1 PTFE pipe support or bearing plate.15$ - 0$ - 0
Pipe Support (Pipes 4" or Less)- Misc. Hardware - Replace Missing/Corroded/Damaged Bolts or U-Bolts on Pipe Support System (1 Repair includes either 2 Plastic coated U-bolts to restrain pipe or 1 set of hardware to anchor pipe support to concrete or other foundation/substructure).5$ - 0$ - 0
Pipe Support (Pipes > 4") - Misc. Hardware - Replace Missing/Corroded/Damaged Bolts or U-Bolts on Pipe Support System (1 Repair includes either 2 Plastic coated U-bolts to restrain pipe or 1 set of hardware to anchor pipe support to concrete or other foundation/substructure).5$ - 0$ - 0
Signage - Repair includes 1 Metal Sign up to 4 SF in Area.12$ - 0$ - 0
Tank Chime sealant repair - 250 LF per Installation250
Valves, Check Valves (X ≤ 2 Inches). Repair includes replacement of 1 valve. (Carbon Steel)3$ - 0$ - 0
Valves, Check Valves (2 Inches < X ≤ 4 Inches). Repair includes replacement of 1 valve. (Carbon Steel)3$ - 0$ - 0
Valves, Check Valves (4 Inches < X ≤ 8 Inches). Repair includes replacement of 1 valve. (Carbon Steel)3$ - 0$ - 0
Valves, Diaphragm Control Valve (X ≤ 2 Inches). Repair includes rebuilding only of valve. (Carbon Steel or Stainless)2$ - 0$ - 0
Valves, Diaphragm Control Valve (2 Inches < X ≤ 4 Inches). Repair includes rebuilding only of valve. (Carbon Steel or Stainless)2$ - 0$ - 0
Valves, Double Block and Bleed Valve (2 Inches < X ≤ 4 Inches). Repair includes replacement of 1 valve. (Carbon Steel)2$ - 0$ - 0
Valves, Double Block and Bleed Valve (4 Inches < X ≤ 8 Inches). Repair includes replacement of 1 valve. (Carbon Steel)2$ - 0$ - 0
Valves, Manually Operated (ie Ball, Gate, Butterfly etc) (X ≤ 2 Inches). Repair includes replacement of 1 valve. (Carbon Steel)2$ - 0$ - 0
Valves, Manually Operated (ie Ball, Gate, Butterfly etc) (2 Inches < X ≤ 4 Inches). Repair includes replacement of 1 valve. (Carbon Steel)2$ - 0$ - 0
Valves, Manually Operated (ie Ball, Gate, Butterfly etc) (4 Inches < X ≤ 8 Inches). Repair includes replacement of 1 valve. (Carbon Steel).2$ - 0$ - 0
Valves, Manually Operated Plug (X ≤ 2 Inches). Repair includes replacement of 1 valve. (Carbon Steel)2$ - 0$ - 0
Valves, Manually Operated Plug (2 Inches < X ≤ 4 Inches). Repair includes replacement of 1 valve. (Carbon Steel)2$ - 0$ - 0
Valves, Manually Operated Plug (4 Inches < X ≤ 8 Inches). Repair includes replacement of 1 valve. (Carbon Steel).2$ - 0$ - 0
Valves, Pressure Relief Valves or Thermal Relief Valves. Repair includes replacement of Pressure or Thermal Relief Valve. (Carbon)10$ - 0$ - 0
Valves, Pressure Relief Valves or Thermal Relief Valves. Repair includes replacement of Pressure or Thermal Relief Valve. (Stainless Steel)10$ - 0$ - 0
Joint Sealant (Reference PWS 3.4.2.1) - ≤800 LF per Site
(17 Sites)13,600$ - 0$ - 0
Crack Repair (Reference PWS 3.4.2.1) - ≤800 LF per Site
(17 Sites)13,600$ - 0$ - 0
Touch-Up Coating Repair (Reference PWS 3.4.2.2) - 200 SF per Site
(17 Sites)3,400$ - 0$ - 0
TOTALS:$ - 0
OPTION YEAR 1
CATEGORYREPAIRS PER YEARUNIT PRICETOTAL
Air eliminators2$ - 0$ - 0
Bollards - Repair includes Prep and Recoat one Bollard up to 6" diameter and 48" tall or provide plastic cover for same. Applicable markings are included as part of repair.40$ - 0$ - 0
Deadman (Hydraulic) - Includes replacement of Deadman Handle and Cord/Hose.2$ - 0$ - 0
Deadman (Electronic) - Includes replacement of Deadman Handle and Cord/Hose.2$ - 0$ - 0
Dispenser Breakaway Connections - Includes Replacement of 1 Breakaway for Hoses ≤ 2".10$ - 0$ - 0
Dispenser Hose Retractors - Includes Replacement of 1 Retractor ≤ 10' in length.10$ - 0$ - 0
Dispenser Hose Swivels - Includes Replacement of 1 Swivel for Hoses ≤ 2".10$ - 0$ - 0
Dispenser Nozzles - Includes Replacement of 1 Dispenser Nozzle for Hoses ≤ 2".10$ - 0$ - 0
Emergency Fuel Shutoff (EFSO) Pushbutton Station - Includes Replacement and Wiring of Emergency Shuttoff Pushbutton Switch and Cover. Does not include troubleshooting or replacing wiring between EFSO Pushbutton and control panel.3$ - 0$ - 0
Flange Isolation Kit - 1 Repair includes complete isolation kit for a flanged connection (Gasket, Sleeves, Insulating Washers, etc.) for up to 8" piping.2$ - 0$ - 0
Flow Indicator Sight Glass Replacement3$ - 0$ - 0
Fuel Hoses 2-4 inches Diameter - Repair includes providing 1 hose 2 to 4 inches in diameter and less than 20 feet in length.3$ - 0$ - 0
Fuel hoses under 2 inches in diameter and less than 20 feet in length - Replacement.15$ - 0$ - 0
Gauges - Replace 1 Differential Pressure Gauge Replacement2$ - 0$ - 0
Gauges - Replace 1 Pressure or Pressure/Vacuum Gauges10$ - 0$ - 0
Ground Reel - Replace a single heavy duty Static Grounding reel to include 100 feet of 3/32" Nylon coated wire and a heavy duty ground clamp (MIL-C-83413/7).4$ - 0$ - 0
Hardware Replacement - Repair includes all bolts, nuts, washers, etc. for a flanged connection for piping ≤ 8" in diameter.50$ - 0$ - 0
Hose End Pressure Regulator. Includes Replacing 1 Hose End Pressure Regulator2$ - 0$ - 0
Load, Offload, and Refueling Nozzle Replacement2$ - 0$ - 0
Markings - Misc. System Components (Valves, Pumps, Meters, Hydrant Pit Covers, etc.). Repair Includes Providing Markings for 1 System Component.6$ - 0$ - 0
Markings - Pipe Markings. A single marking is defined as all required product identification and directional arrows along a minimum of 25 linear feet.10$ - 0$ - 0
Markings - Tank Markings - Tanks 420,000 Gallons and Under. 1 Repair includes all markings on tank required by UFC 3-460-01.10$ - 0$ - 0
Markings - Tank Markings - Tanks over 420,000 gallons. 1 Repair includes all markings on tank required by UFC 3-460-01.4$ - 0$ - 0
Hose and Hydrant System Nozzle / Hose Covers or Dust Caps. 1 Repair includes the hose end cover or dust caps for 1 hose.10$ - 0$ - 0