This document provides details for a federal contract solicitation to upgrade infrastructure at the St. Louis John Cochran Veterans Affairs Medical Center. The solicitation seeks a general contractor to construct twenty-four new telecommunication rooms to improve the electrical, communication, security, and fiber optic infrastructure throughout Building 1 on the medical center campus. Specific upgrades include electrical panel replacement and expansion, upgrading power systems to include normal and emergency supplies, bonding and grounding, UPS installation, integrating with the building management system, assessing and renovating HVAC systems, expanding and renovating existing spaces through demolition and new construction, building a new exterior telecommunication tower, installing new data outlets and upgrading network cabling to Category 6A, and conducting hazardous material abatement as required. The selected contractor will furnish all labor, materials, tools and equipment to complete the upgrades. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A/E ARCHITECT / ENGINEER
AAHX AIR TO AIR HEAT EXCHANGER
AB AIR BLENDER
AAV AUTOMATIC AIR VENT
ACC AIR-COOLED CONDENSER
ACCH AIR-COOLED CHILLER
ACCU AIR-COOLED CONDENSING UNIT
ACU AIR CONDITIONING UNIT
ACD AUTOMATIC CONTROL DAMPER,
MODULATING
ACD-TP AUTOMATIC CONTROL DAMPER,TWO
POSITION
AD ACCESS DOOR
AF AFTER FILTER
AFCV AIR FLOW CONTROL VALVE
AFF ABOVE FINISHED FLOOR
AFMD AIR FLOW MEASURING DEVICE
AFW AIR FOIL WHEEL (FAN)
AHU AIR-HANDLING UNIT
AMP AMPERAGE
AP ACCESS PANEL
APD AIR PRESSURE DROP
ARI AIR CONDITIONING AND
REFRIGERATION INSTITUTE
AS AIR SEPARATOR
ASME AMERICAN SOCIETY OF MECHANICAL
ENGINEERS
AW AIR WASHER
AXF AXIAL FLOW
B BOILER
BD BUTTERFLY DAMPER
BDD BACKDRAFT DAMPER
BDR BASE BOARD RADIATOR
BFP BACKFLOW PREVENTER
BFT BOILER PLANT FIRE TUBE
BHP BRAKE HORSEPOWER
BHW HOT WATER HEATING BOILER
BHX BOILER BLOWDOWN HEAT
EXCHANGER
BIW BACKWARD INCLINED WHEEL (FAN)
BSC BIOLOGICAL SAFETY CABINETS
BT BUFFER TANK
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
C CENTIGRADE (CELSIUS)
CC COOLING COIL
CCD COOLING COIL CONDENSATE DRAIN
CENT CENTRIFUGAL
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CFT CUBIC FEET
CFP CHEMICAL FEED PUMP
CH CHILLER
CHWP CHILLED WATER PUMP
CHW CHILLER WATER
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CI CAST IRON
CM CARBON MONOXIDE
CM CUBIC METER
CM/S CUBIC METER PER SECOND
CO CLEAN OUT
CO2 CARBON DIOXIDE
COMP COMPRESSOR UNIT
COP COEFFICIENT OF PERFORMANCE
CP CONDENSATE PUMP
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CV CONSTANT VOLUME
CW COLD WATER (POTABLE)
CHWCC CHILLED WATER COOLING COIL
D DAMPER - AUTOMATIC
D-1 OUTDOOR AIR DAMPER
D-2 RETURN AIR DAMPER
D-3 RELIEF AIR DAMPER
D-4 ECONOMIZER OUTDOOR AIR
DAMPER
dB DECIBELS Db DRY-BULB TEMPERATURE
DDC DIRECT DIGITAL CONTROLS
DEG DEGREE
DF DIFFUSER
DIA DIAMETER
DIW DEIONIZED WATER
DP DEW POINT TEMPERATURE
DP DIFFUSER PLATE
DPA DIFFERENTIAL PRESSURE
ASSEMBLY
DPS DIFFERENTIAL PRESSURE SENSOR
DX DIRECT EXPANSION
DXCC DIRECT EXPANSION COOLING COIL
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
ECC ENGINEERING CONTROL CENTER
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
EG EXHAUST GRILLE
EGS EMERGENCY GAS SHUTOFF
EH EXHAUST HOOD
EJ EXPANSION JOINT
EMD END OF MAIN DRIP (STEAM)
ENT ENTERING
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
EX EXISTING
F FAHRENHEIT
F&T FLOAT AND THERMOSTATIC
F/SDPR COMBINATION FIRE SMOKE DAMPER
FA FREE AREA
FC FLEXIBLE CONNECTION
FCU FAN COIL UNIT (4 PIPE)
FCW FORWARD CURVED WHEEL (FAN)
FD FLOOR DRAIN
FD FIRE DAMPER
FF FINAL FILTER
FM FLOW METER
FPM FEET PER MINUTE
FPS FEET PER SECOND
FRP FIBER REINFORCED POLYESTER
FS FLOW SWITCH
FSTAT FREEZESTAT
FT FEET
FT-LB FOOT-POUND
FTR FIN TUBE RADIATION
FV FACE VELOCITY
GA GAUGE
GAL GALLONS
GH GRAVITY HOOD
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GS GALVANIZED STEEL
H HUMIDIFIER
H&CW HOT & COLD WATER
HAC HOUSEKEEPING AID CLOSET
HB HOSE BIBB
HC HEATING COIL
HD HEAD
HD HOOD
HHW HEATING HOT WATER
HHWC HEATING HOT WATER COIL
HHWP HEATING HOT WATER PUMP
HHWR HEATING HOT WATER RETURN
HHWS HEATING HOT WATER SUPPLY
HOA HAND/OFF/AUTOMATIC
HP HEAT PUMP
HP HORSEPOWER
HPDT HIGH PRESSURE DRIP TRAP
HPR HIGH PRESSURE RETURN (STEAM
CONDENSATE)
HPS HIGH PRESSURE SUPPLY (STEAM)
HRC HEAT RECOVERY COIL
HRD HEAT RECOVERY DEVICE
HRP HYDRONIC RADIANT (CEILING) PANEL
HRW HEAT RECOVERY WHEEL
HSTAT HUMIDISTAT
HUM HUMIDIFIER UNIT MOUNTED
HVU HEATING AND VENTILATING UNIT
HW HOT WATER
HWC HOT WATER COIL
HWUH HOT WATER UNIT HEATER
HX HEAT EXCHANGER
Hz HERTZ
I/O INPUT/OUTPUT
IAQ INDOOR AIR QUALITY
IBT INVERTED BUCKET TRAP
ICF IN-LINE CENTRIFUGAL FAN
ICU INTENSIVE CARE UNIT
ID INSIDE DIAMETER
IFB INTEGRAL FACE AND BYPASS
IN INCHES
IN HG INCHES OF MERCURY
IN WC INCH WATER COLUMN
IN WG INCH WATER GAUGE
IN-LB INCH-POUND
IPLV INTEGRATED PART LOAD VALUE
IRH INFRARED HEATER
IS INSECT SCREEN
IV INLET VANES
kg KILOGRAM kg/HR KILOGRAM PER HOUR kPa KILOPASCAL kW KILOWATT kWh KILOWATT HOUR
L LITER
L/s LITERS PER SECOND
LAT LEAVING AIR TEMPERATURE
LBS/HR POUNDS PER HOUR
LF LINEAR FOOT (FEET)
LH LATENT HEAT
LPR LOW PRESSURE RETURN (STEAM
CONDENSATE)
LPS LOW PRESSURE SUPPLY (STEAM)
LSD LINEAR SLOT DIFFUSER
LTCP LOCAL TEMPERATURE CONTROL
PANEL
LVG LEAVING
LVR LOUVER
LWT LEAVING WATER TEMPERATURE
M METER, SI UNIT
M/s METERS PER SECOND (OR
METERS/SECOND)
MA MIXED AIR
MAT MIXED AIR TEMPERATURE
MAV MANUAL AIR VENT
MAX MAXIMUM
MB MIXING BOX
MBH 1000 BTUH
MCA MINIMUM BRANCH CIRCUIT AMPACITY
MER MECHANICAL EQUIPMENT ROOM
MERV MINIMUM EFFICIENCY REPORTING
VALUE
MHP MOTOR HORSEPOWER
MIN MINIMUM
MM MILLIMETER
MOV MOTOR OPERATED VALVE
MPR MEDIUM PRESSURE RETURN (STEAM
CONDENSATE)
MPS MEDIUM PRESSURE SUPPLY (STEAM)
MTD MEAN TEMPERATURE DIFFERENCE
MVD MANUAL VOLUME DAMPER
NA NOT APPLICABLE
NC NOISE CRITERIA
NC NORMALLY CLOSED
NO NORMALLY OPEN
NOAA NATIONAL OCEANIC & ATMOSPHERIC
ADMINISTRATION
NOM NOMINAL
NPLV NON-STANDARD PART LOAD VALUE
NPSH NET POSITIVE SUCTION HEAD
NTS NOT TO SCALE
OA OUTSIDE AIR
OAI OUTSIDE AIR INTAKE
OD OUTSIDE DIAMETER
OR OPERATING ROOM
OSA OUTSIDE SUPPLY AIR
(CONDITIONED)
P PUMP
PC PUMPED CONDENSATE
PCF POUNDS PER CUBIC FOOT (FEET)
PD PRESSURE DROP
PF PRE-FILTER
PG PRESSURE GAGE
PHC PREHEAT COIL
PHCP PREHEAT COIL PUMP
PPM PARTS PER MILLION
PRV PRESSURE REGULATING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH –
ABSOLUTE
PSIG POUNDS PER SQUARE INCH – GAGE
PSS PRIMARY SECONDARY SYSTEM
PSV PRESSURE SAFETY VALVE
R/E RETURN OR EXHAUST
RA RETURN AIR
RAT RETURN AIR TEMPERATURE
RDS ROOM DATA SHEETS
REA RELIEF AIR
RF RETURN FAN
RG RETURN GRILLE
RH RELATIVE HUMIDITY
RHC REHEAT COIL
RL REFRIGERANT LIQUID LINE
RLA RUN LOAD AMPERE
RPM REVOLUTIONS PER MINUTE
RS REFRIGERANT SUCTION
RTU ROOF TOP UNIT
RV RELIEF VALVE
SA SUPPLY AIR
SAD SOUND ATTENUATING DEVICE
SAT SUPPLY AIR TEMPERATURE
SC SHADING COEFFICIENT
SCFM STANDARD CUBIC FEET PER MINUTE
SCR SILICON CONTROLLED RECTIFIER
SD SMOKE DETECTOR
SD SUPPLY AIR DIFFUSER
SDPR SMOKE DAMPER
SDR SMOKE DAMPER (RETURN)
SDS SMOKE DAMPER (SUPPLY)
SEN SENSIBLE HEAT
SF SUPPLY FAN
SH STEAM HUMIDIFIER
SHC STEAM HEATING COIL
SI SQUARE INCHES
SP STATIC PRESSURE
SP GR SPECIFIC GRAVITY
SPD SUPPLY PROCESS AND
DISTRIBUTION
SPRV STEAM PRESSURE REDUCING VALVE
SPS STATIC PRESSURE SENSOR
SQ FT SQUARE FOOT (FEET)
SR SUPPLY AIR REGISTER
SS STAINLESS STEEL
SSR SOLID SEPARATOR
ST STEAM TRAP
SV STEAM SAFETY VALVE
SVS STEAM VENT SILENCER
T & PCV TEMPERATURE AND PRESSURE
CONTROL VALVE
TAB TESTING, ADJUSTING, BALANCE
TD TEMPERATURE DIFFERENCE
TDH TOTAL DYNAMIC HEAD
TDS TOTAL DISSOLVED SOLIDS
TP TRAP
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
TU TERMINAL UNIT
UC UNDER CUT
UH UNIT HEATER
UL UNDERWRITERS LABORATORY
V VALVE
VAF VANE-AXIAL FAN
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER (MANUAL
OPPOSED BLADE)
VFD VARIABLE FREQUENCY DRIVE
VHA VETERANS HEALTH ADMINISTRATION
VI VIBRATION ISOLATOR
VP VACUUM PUMP
VPS VARIABLE PRIMARY SYSTEM
VR VACUUM (STEAM CONDENSATE)
RETURN
VSD VARIABLE SPEED DRIVE
VUH VERTICAL UNIT HEATER
W WATTS
Wb WET-BULB (TEMPERATURE)
WFCV WATER FLOW CONTROL VALVE
WFM WATER FLOWMETER
WFMD WATER FLOW MEASURING DEVICE
WG WATER GAGE
WPD WATER SIDE PRESSURE DROP
XT EXPANSION TANK
YR YEAR
MECHANICAL ABBREVIATIONS
EXISTING
NEW WORK KEYNOTE
DEMOLITION KEYNOTE
NEW BOLD TEXT INDICATES NEW ITEM
ITALICIZED TEXT INDICATES EXISTING ITEM
DIFFUSER TAG: TAG CALLOUT : CFM
DETAIL OR SECTION MARK
SHOWN ON DRAWING
DETAIL MODULE NUMBER
CONNECT TO EXISTING
LIMIT OF DEMOLITION
EQUIPMENT TAG
ANNOTATION SYMBOLS
##-VAV-#
SD-## ###
1. VERIFY EXISTING CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY COR/VA REGARDING CONFLICTS BEFORE PROCEEDING WITH WORK.
2. REMOVED ITEMS REMAIN PROPERTY OF GOVERNMENT UNTIL COR/VA DETERMINES THAT THEY ARE NOT REQUIRED. REMOVE FROM SITE ITEMS NOT BEING RETAINED BY
GOVERNMENT OR REINSTALLED AS PART OF THIS WORK.
3. DO NOT DISTURB ITEMS NOT INDICATED FOR DEMOLITION.
4. VERIFY SIZE AND LOCATION OF EXISTING UTILITIES PRIOR TO START OF DEMOLITION. RELOCATE, REMOVE AND ADJUST MECHANICAL AND ELECTRICAL ITEMS AS
NECESSARY TO COORDINATE WITH NEW WORK.
5. AFTER DEMOLITION IS COMPLETE, PATCH AND REPAIR FINISHES TO MATCH EXISTING ADJACENT CONDITIONS.
6. COORDINATE DEMOLITION WITH COR/VA. SUBMIT SHUTDOWN PLAN AND SCHEDULE TO COR/VA FOR REVIEW AND APPROVAL.
7. PROTECT EXISTING UTILITIES TO REMAIN FROM DAMAGE DURING DEMOLITION. REPAIR UTILITIES AND SERVICES DAMAGED AT NO ADDITIONAL COST.
8. TEMPORARILY MOVE OR TAKE EQUIPMENT OUT OF SERVICE AS NECESSARY TO COMPLETE WORK.
9. SAWCUT OR CORE DRILL CONCRETE FLOOR AS REQUIRED FOR DEMOLITION WORK INDICATED. COORDINATE WITH NEW MECHANICAL WORK AND WORK OF OTHER
TRADES.
MECHANICAL DEMOLITION GENERAL NOTES
1. WORK SHALL CONFORM TO APPLICABLE LOCAL, STATE, AND NATIONAL CODES AND APPLICABLE VA STANDARDS.
2. INSTALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS.
3. PROVIDE NEW MATERIALS, EQUIPMENT AND PRODUCTS INCORPORATED IN THE WORK, OF A SUITABLE GRADE FOR THE PURPOSES INTENDED.
4. WHERE POSSIBLE, PROVIDE STANDARD PRODUCTS OF THE VARIOUS MANUFACTURERS EXCEPT WHERE SPECIAL CONSTRUCTION OR PERFORMANCE FEATURES ARE
REQUIRED.
5. EQUIPMENT OR MATERIAL DEVIATIONS FROM INDICATED CONTRACT REQUIREMENTS SHALL BE SUBJECT TO THE APPROVAL OF THE COR/VA. SUBMIT PROPOSED EQUIPMENT DEVIATIONS THAT ARE SIMILAR BOTH IN QUALITY AND CAPACITY TO THAT EQUIPMENT SPECIFIED, AS SOLELY DETERMINED BY THE COR/VA.
6. PROVIDE MECHANICAL EQUIPMENT THAT IS LISTED AND LABELED BY UNDERWRITERS LABORATORIES (U.L.).
7. INSTALL EQUIPMENT AS INDICATED, ALLOWING FOR SUFFICIENT ACCESS AND CLEARANCE SPACE FOR EQUIPMENT MAINTENANCE, REPAIRS, AND REPLACEMENT.
8. INSTALL EQUIPMENT WITH PROPER CLEARANCES FOR REQUIRED PIPING AND ELECTRICAL SERVICES AND CONNECTIONS. INSTALL EQUIPMENT WITH REQUIRED ACCESS AND CLEARANCES IN ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS AND APPLICABLE CODES AND STANDARDS.
9. COORDINATE LOCATION, INSTALLATION, AND ROUTING OF DUCTWORK, PIPING, AND EQUIPMENT WITH WORK OF ALL OTHER TRADES.
10. PROVIDE SUPPORTS FOR MECHANICAL EQUIPMENT. COORDINATE SUPPORT LOCATIONS WITH ALL CONTRACTORS PRIOR TO INSTALLATION.
11. PROVIDE POWER CONNECTIONS TO EQUIPMENT PROVIDED UNDER THIS CONTRACT AS WORK OF DIVISION 26.
12. PROVIDE CONTROL WIRING FOR MECHANICAL EQUIPMENT AS WORK OF DIVISION 23.
13. DUCTWORK AND PIPING LAYOUTS AND LOCATIONS ARE SCHEMATIC. DO NOT SCALE THESE DRAWINGS. COORDINATE AND DETERMINE EXACT ROUTING OF DUCTWORK
AND PIPING IN THE FIELD.
14. FIELD VERIFY DIMENSIONS BY ACTUAL MEASUREMENT AND OBSERVATION BEFORE ORDERING OR FABRICATING DUCTWORK, PIPING OR EQUIPMENT.
15. NOTIFY COR/VA REGARDING DISCREPANCIES BETWEEN CONTRACT DOCUMENTS AND EXISTING CONDITIONS OR DIMENSIONS BEFORE PERFORMING WORK. FAILURE TO VERIFY AND REPORT SHALL CONSTITUTE CONTRACTOR'S ACCEPTANCE OF EXISTING CONDITIONS AS FIT FOR THE PROPER EXECUTION OF THE WORK.
16. SEE ARCHITECTURAL DRAWINGS FOR FINAL LOCATION OF CEILING INSTALLED EQUIPMENT.
17. INSTALL DUCTWORK AND PIPING AS HIGH AS POSSIBLE AND AS CLOSE AS POSSIBLE TO BUILDING WALLS, CEILING AND FLOOR AND ROOF STRUCTURE. PROVIDE OFFSETS, FITTINGS, AND DIMENSIONAL TRANSITIONS NOT SHOWN BUT REQUIRED TO MAINTAIN MINIMUM CLEAR SPACE TO BUILDING SURFACES AT NO ADDITIONAL
COST.
18. PATCH, PAINT AND CLEAN SURFACES SUSTAINING DAMAGE ASSOCIATED WITH MECHANICAL WORK OF THIS CONTRACT, UNLESS NOTED OTHERWISE.
19. SUBMIT BOUND SET OF OPERATING AND MAINTENANCE INSTRUCTIONS FOR EQUIPMENT AT COMPLETION OF PROJECT.
20. INSTALL ESCUTCHEONS IN ALL PLACES WHERE PIPING PENETRATES A WALL IN AN EXPOSED LOCATION.
21. MAKE A COMPLETE REVIEW OF DRAWINGS, INCLUDING SCHEDULES AND DETAILS, PRIOR TO BEGINNING MECHANICAL SYSTEM INSTALLATION. RESOLVE CONFLICTS WITH
COR/VA.
22. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION AND ARRANGEMENT OF PIPING SYSTEMS.
23. INSTALL PIPING INDICATED TO BE EXPOSED AND PIPING IN EQUIPMENT ROOMS AND SERVICE AREAS AT RIGHT ANGLES OR PARALLEL TO BUILDING WALLS. DIAGONAL
RUNS ARE NOT ACCEPTABLE UNLESS SPECIFICALLY INDICATED OTHERWISE.
24. INSTALL PIPING FREE OF SAGS AND BENDS.
25. INSTALL PIPING TO ALLOW APPLICATION OF INSULATION.
26. PIPING SHALL NOT BE ROUTED OVER TELECOM OR ELECTRICAL CLOSETS/ROOMS UNLESS THE PIPING SERVES THE ROOM.
27. PREPARE DRAWINGS SHOWING MECHANICAL SYSTEMS AND EQUIPMENT FOR COORDINATION WITH WORK OF OTHER DIVISIONS AND WORK BY THE GOVERNMENT.
A. INCLUDE PLAN VIEWS, SECTIONS, AND ELEVATIONS, AS REQUIRED, TO FULLY COORDINATE ALL NEW WORK WITH ITSELF AND EXISTING CONDITIONS.
B. DRAWINGS SHALL SHOW, BUT NOT BE LIMITED TO, ALL DUCTWORK, AIR DISTRIBUTION, MECHANICAL EQUIPMENT, MECHANICAL PIPING, FIRE PROTECTION PIPING, PLUMBING PIPING, CABLE TRAYS, LIGHTING FIXTURES, CEILING GRID AND HEIGHT, BEAMS AND JOISTS (WITH ELEVATIONS MARKED), ELECTRICAL CONDUIT LARGER THAN 2 INCHES IN DIAMETER AND OTHER CEILING MOUNT DEVICES OR EQUIPMENT THAT PROTRUDE INTO THE CEILING CAVITY.
C. IF THERE ARE OUTSTANDING ISSUES THAT CANNOT BE RESOLVED, CONSULT WITH COR/VA FOR GUIDANCE AND MAKE CORRECTIONS IN ACCORDANCE WITH
DIRECTIONS GIVEN.
D. DO NOT BEGIN FABRICATION OR PLACE EQUIPMENT ORDERS UNTIL COORDINATION DRAWINGS HAVE BEEN APPROVED.
28. INSTALLATION COMMENCED PRIOR TO COORDINATION DRAWING APPROVAL IS TAKEN AT THE CONTRACTORS OWN RISK. MODIFY, MOVE OR RECONFIGURE WORK
LACKING COORDINATION AT NO ADDITIONAL COST.
29. ALL HUMIDITY AND TEMPERATURE SENSORS SHALL BE LOCATED ON THE RETURN SIDE OF THE HVAC EQUIPMENT.
MECHANICAL GENERAL NOTES
CO2 CARBON DIOXIDE SENSOR
HUMIDISTAT OR HUMIDITY SENSOR
SUPPLY DIFFUSER
RETURN GRILLE
EXHAUST GRILLE
ROUND FLEX DUCT
LINEAR SLOT DIFFUSER
BALANCING DAMPER
FIRE DAMPER
SMOKE DAMPER
D
R INCLINED RISE, IN
DIRECTION OF AIRFLOW
INCLINED DROP, IN DIRECTION
OF AIRFLOW
CONNECT NEW DUCT
TO EXISTING
LIMIT OF DEMOLITION
VANED ELBOW (PROVIDE ALL
SQUARE OR RECTANGULAR
ELBOWS WITH VANES EVEN IF
SYMBOL IS MISSING)
STANDARD RADIUS ELBOW
(LONG RADIUS)
10x8 NEW DUCT (INSIDE
DIMENSIONS: WIDTH X DEPTH)
EXISTING DUCT TO REMAIN
EXISTING DUCT TO BE
DEMOLISHED
DUCT TRANSITION
END MOUNTED OR SIDEWALL GRILLE
SUPPLY
RETURN45°
45°
DN
DN
UP
UP
DNUP
STANDARD BRANCH SUPPLY OR
RETURN, NO SPLITTER (45° TAP)
SUPPLY DUCT (UP & DOWN)
EXHAUST DUCT (UP & DOWN)
RETURN DUCT (UP & DOWN)
S-60
S-15
CR-15
CHWS/CHS
CHWR/CHR
HIGH PRESSURE STEAM
PIPING (60 PSI)
LOW PRESSURE STEAM PIPING
(15 PSI AND BELOW)
LOW PRESSURE STEAM
CONDENSATE RETURN
CHILLED WATER SUPPLY PIPING
CHILLED WATER RETURN PIPING
PIPE UP
PIPE DOWN
BOTTOM CONNECTION
TOP CONNECTION
CAPPED OR PLUGGED PIPE
GLOBE VALVE
GATE VALVE
BALL VALVE
STEAM SAFETY VALVE
PRESSURE REGULATING VALVE
WYE STRAINER VALVE
BALANCING VALVE
MODULATING TWO-WAY CONTROL
VALVE
STEAM TRAP
D CONDENSATE DRAIN LINE
CR-60 HIGH PRESSURE STEAM
CONDENSATE RETURN
HWS
HWR
HEATING HOT WATER SUPPLY
PIPING
HEATING HOT WATER RETURN PIPING
RLS REFRIGERANT LINE SET (LIQUID
AND SUCTION)
CONNECT TO EXISTING PIPE
LIMIT OF DEMOLITION
INLINE CENTRIFUGAL PUMP
STEAM PRESSURE REDUCING
VALVE
DRAIN VALVE
TEST PLUG
SUPPLY
TERMINAL UNIT SUPPLY
DUCT BRANCH (CONICAL
TAP)
CHECK VALVE
FIRE / SMOKE DAMPER
VANED ELBOW (SHORT RADIUS) S-30
CR-30
MEDIUM PRESSURE STEAM
PIPING (16 PSI AND 59 PSI)
MEDIUM PRESSURE STEAM
CONDENSATE RETURN
THERMOSTAT OR TEMPERATURE SENSOR
TWO POSITION CONTROL VALVE
MODULATING THREE-WAY
CONTROL VALVE
T
H
F
SD
FS
MECHANICAL LEGEND
MOTORIZED DAMPER GS GLYCOL SUPPLY
GR GLYCOL RETURN
AIR VENT - MANUAL
AIR VENT - AUTOMATIC
DIRECTION OF FLOW ARROW
Engineers Architects th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing # of
VA Health Care System Approval:
Revision: Date:
ARCHITECT/ENGINEER:
JOHN COCHRAN DIVISION
915 NORTH GRAND BLVD - ST. LOUIS, MO 63106
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.
FULLY SPRINKLERED
C R e v it p ro je c ts
\M P
F
-1
S T
L -J
C -E
H R
M
G e n e ra l_ tb u d a i.
rv t
/2
/2
:0 :5
P
M
21-124 MECHANICAL GENERAL
INFORMATION
EHRM INFRASTRUCTURE UPGRADES 657-21-700JC
BID DOCUMENTS
SMHNOVEMBER 28, 2022 RBK
1 43
00-M-001
TELECOMMUNICATION ROOM
(TR)
70 [ 21 ] 95 [ 35 ] 90 [ 32 ] 80 41 [ 5 ] 28 [ -2 ] 8 NA NA
INDOOR AREA DESIGN CONDITIONS
OUTDOOR DESIGN
CONDITIONS
NA NA 95.5 [ 35 ] 76.8 [ 25 ] NA 6.6 [ -14 ] NA NA -5 [ -21 ]
°F [°C] °F [°C] °F [°C] °F [°C] °F [°C] °F [°C]
TEMP WET BULB TEMP
% HUMIDITY
TEMP DEWPOINT TEMP
% HUMIDITY
DESIGN CONDITIONS
ROOM
SETPOINT
TEMPERATURE
SUMMER WINTER
LOWEST AVERAGE
ANNUAL DEWPOINT
HVAC DESIGN DATA
DocuSign Envelope ID: EEF24117-071F-4ECB-9003-96B00DAFAB5F
11/22/2022
F FAHRENHEIT
FA FROM ABOVE
FB FROM BELOW
FBO FURNISHED BY OTHERS
FCO FLOOR CLEANOUT
FCW FILTERED COLD WATER
FD FLOOR DRAIN
FDC FIRE DEPARTMENT (HOSE)
CONNECTION
FM FLOW METER
FOP FUEL OIL PUMP
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FOV FUEL OIL VENT
FS FLOOR SINK
FU FIXTURE UNITS
G GALLON
GC GENERAL CONTRACTOR
GCO GRADE CLEANOUTS
GD GARBAGE DISPOSAL
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GRS GAS REGULATOR STATION
GT GREASE TRAP
GVTR GAS VENT THROUGH ROOF
GWH GAS FIRED WATER HEATER
H&CW HOT AND COLD WATER
HB HOSE BIBB (INTERIOR)
HD HUB DRAIN
HEX HEAT EXCHANGER
HP HORSEPOWER
HS HAND SINK
HST HOT WATER STORAGE TANK
(DOMESTIC)
HWB HOT WATER BOILER
HWCP HOT WATER CIRCULATING PUMP
HWP HOT WATER PUMP
HYD HYDRANT
ICW INDUSTRIAL COLD WATER
INV INVERT
IPC INTERNATIONAL PLUMBING CODE
IRW IRRIGATION WATER
IW INDIRECT WASTE
IWH INSTANTANEOUS WATER HEATER
IWR INDUSTRIAL WATER RETURN
IWS INDUSTRIAL WATER SUPPLY
KW KILOWATT
KWHR KILOWATT-HOUR
L/S LITER PER SECOND
LA LABORATORY AIR
LAV LAVATORY
LBS/HR POUNDS PER HOUR
LCW LABORATORY COLD WATER
LHW LABORATORY HOT WATER
LNG LIQUID NATURAL GAS
LOX LIQUID OXYGEN
LV LABORATORY VACUUM
LW LOW WATER
M METER
MA MEDICAL AIR
MAV MANUAL AIR VENT
MBH THOUSANDS OF BTU PER HOUR
MC MECHANICAL CONTRACTOR
MED MEDICAL
MER MECHANICAL EQUIPMENT ROOM
MH MANHOLE
MOU MEMORANDUM OF UNDERSTANDING
MSB MOP SINK BASIN
MV MEDICAL VACUUM
N2 NITROGEN
N2O NITROUS OXIDE
NC NORMALLY CLOSED
NG NATURAL GAS
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NOM NOMINAL
NPW NON POTABLE WATER
NTS NOT TO SCALE
O2 OXYGEN
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OR OPERATING ROOM
OVFL OVERFLOW
PA PASCAL
PC PLUMBING CONTRACTOR
PD PRESSURE DROP
PDI PLUMBING AND DRAINAGE INSTITUTE
PG PRESSURE GAUGE
PP PLUMBING PUMP
PPM PARTS PER MILLION
PRS PRESSURE REDUCING STATION
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH -
ABSOLUTE
PSIG POUNDS PER SQUARE INCH - GAUGE
PTRV PRESSURE TEMPERATURE RELIEF
VALVE
PW POTABLE WATER
RD ROOF DRAIN
RDL ROOF DRAIN LEADER
RL ROOF LEADER
RO REVERSE OSMOSIS
RWL RAIN WATER LEADER
SAN SANITARY SEWER
SCFM STANDARD CUBIC FOOT/MIN
SCW SOFTENED COLD WATER
SDMH STORM DRAIN MANHOLE
SP SUMP PUMP
SPR SPRINKLER LINE
SQFT SQUARE FOOT
SS STAINLESS STEEL
ST STORAGE TANK
SW STORM WATER
TCV TEMPERATURE CONTROL VALVE
TD TRENCH DRAIN
TDH TOTAL DYNAMIC HEAD
TDL TEMPERATURE DIFFERENTIAL
TEMP TEMPERATURE
TMV THERMOSTATIC MIXING VALVE
TP TRAP PRIMER
TSTAT THERMOSTAT
TWR TEMPERED WATER RETURN
TWS TEMPERED WATER SUPPLY
TYP TYPICAL
UPC UNIFORM PLUMBING CODE
V SANITARY VENT
VAC VACUUM
VB VACUUM BREAKER
VCO VACUUM CLEANER OUTLET
VP VACUUM PUMP
VS VENT STACK
VTR VENT THROUGH ROOF
W WASTE
WC WATER CLOSET
WCO WALL CLEANOUT
WG WATER GAUGE
WH WATER HEATER
WHA WATER HAMMER ARRESTOR
WHD WALL HYDRANT
WL WATER LINE
WM WATER METER
WPD WATER PRESSURE DROP
WS WASTE STACK
YCO YARD CLEANOUT
YH YARD HYDRANT
A/E ARCHITECT/ENGINEER
AC ABOVE CEILING
AD AREA DRAIN
AFF ABOVE FINISHED FLOOR
AG AIR GAP
AP ACCESS PANEL
AS AUTOMATIC SPRINKLER
AFG ABOVE FINISHED GRADE
ASD ADJUSTABLE SPEED DRIVE
ASHRAE AMERICAN SOCIETY HEATING,
REFRIGERATING, AIR CONDITIONING
ENGINEERS
ASME AMERICAN SOCIETY OF MECHANICAL
ENGINEERS
ASPE AMERICAN SOCIETY PLUMBING
ENGINEERS
ASR AUTOMATIC SPRINKLER RISER
AV ACID VENT
AW ACID WASTE
BAS BUILDING AUTOMATION SYSTEM
BF BELOW FLOOR
BFP BACKFLOW PREVENTER
BG BELOW GRADE
BH BOOSTER HEATER
BHP BREAK HORSEPOWER
BJ BETWEEN JOISTS
BOP BOTTOM OF PIPE
BSP BLACK STEEL PIPE
BT BATHTUB
BTUH BRITISH THERMAL UNITS PER HOUR
C CELSIUS
CF COMBINATION FIXTURE
CGA COMPRESSED GAS ASSOCIATION
CI CAST IRON
CO CLEANOUT
COND CONDENSATE
CP CONDENSATE PUMP
CS CLINICAL SINK
CV CONTROL VALVE
DA DENTAL COMPRESSED AIR
DCW DOMESTIC COLD WATER
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER RETURN
DHWS DOMESTIC HOT WATER SUPPLY
DF DRINKING FOUNTAIN
DI DEIONIZED WATER
DN DOWN
DOE DEPARTMENT OF ENERGY
DS DOWNSPOUT
DV DENTAL VACUUM
DW DISHWASHER
DWG DRAWING
DWH DOMESTIC WATER HEATER
DWR DRINKING WATER RETURN
DWS DRINKING WATER SUPPLY
DWV DRAIN WASTE VENT
EC ELECTRICAL CONTRACTOR
EL ELEVATION
EMCS ENERGY MONOSERRAT AND CENTRAL
SYSTEM
EPA ENVIRONMENTAL PROTECTION
AGENCY
EPACT ENERGY POLICY ACT
ESC ESCUTCHEON
ESH EMERGENCY SHOWER
ET EXPANSION TANK
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EWS EYEWASH STATION
EX EXISTING
PLUMBING ABBREVIATIONS
1. VERIFY EXISTING CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY COR/VA REGARDING CONFLICTS BEFORE PROCEEDING WITH WORK.
2. REMOVED ITEMS REMAIN PROPERTY OF GOVERNMENT UNTIL COR/VA DETERMINES THAT THEY ARE NOT REQUIRED. REMOVE FROM SITE ITEMS NOT BEING RETAINED BY
GOVERNMENT OR REINSTALLED AS PART OF THIS WORK.
3. DO NOT DISTURB ITEMS NOT INDICATED FOR DEMOLITION.
4. VERIFY SIZE AND LOCATION OF EXISTING UTILITIES PRIOR TO START OF DEMOLITION. RELOCATE, REMOVE AND ADJUST MECHANICAL AND ELECTRICAL ITEMS AS
NECESSARY TO COORDINATE WITH NEW WORK.
5. AFTER DEMOLITION IS COMPLETE, PATCH AND REPAIR FINISHES TO MATCH EXISTING ADJACENT CONDITIONS.
6. COORDINATE DEMOLITION WITH COR/VA . SUBMIT SHUTDOWN PLAN AND SCHEDULE TO COR/VA FOR REVIEW AND APPROVAL.
7. PROTECT EXISTING UTILITIES TO REMAIN FROM DAMAGE DURING DEMOLITION. REPAIR UTILITIES AND SERVICES DAMAGED AT NO ADDITIONAL COST.
8. TEMPORARILY MOVE OR TAKE EQUIPMENT OUT OF SERVICE AS NECESSARY TO COMPLETE WORK.
9. SAWCUT CONCRETE FLOOR AS REQUIRED FOR DEMOLITION WORK INDICATED. COORDINATE WITH NEW PLUMBING WORK AND WORK OF OTHER TRADES.
PLUMBING DEMOLITION GENERAL NOTES
1. WORK SHALL CONFORM TO APPLICABLE LOCAL, STATE, AND NATIONAL CODES AND APPLICABLE VA STANDARDS.
2. INSTALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS.
3. OBTAIN AND PAY FOR PERMITS, FEES, AND INSPECTIONS REQUIRED FOR THIS WORK.
4. PROVIDE NEW MATERIALS, EQUIPMENT AND PRODUCTS INCORPORATED IN THE WORK, OF A SUITABLE GRADE FOR THE PURPOSES INTENDED.
5. EQUIPMENT OR MATERIAL DEVIATIONS FROM INDICATED CONTRACT REQUIREMENTS ARE SUBJECT TO THE APPROVAL OF THE COR/VA. SUBMIT PROPOSED EQUIPMENT DEVIATIONS THAT ARE SIMILAR BOTH IN QUALITY AND CAPACITY TO THAT EQUIPMENT SPECIFIED, AS SOLELY DETERMINED BY THE COR/VA.
6. INSTALL EQUIPMENT AS INDICATED, ALLOWING FOR SUFFICIENT ACCESS AND CLEARANCE SPACE FOR EQUIPMENT MAINTENANCE, REPAIRS, AND REPLACEMENT.
7. SANITARY DRAINAGE PIPING INDICATED IS LOCATED BELOW FLOOR SLAB OR WITHIN WALLS UNLESS NOTED OTHERWISE. SANITARY VENT PIPING INDICATED IS ABOVE
THE CEILING OR WITHIN WALLS UNLESS NOTED OTHERWISE.
8. SUPPORT PIPING SYSTEM AS REQUIRED BY APPLICABLE LOCAL, STATE, AND NATIONAL CODES ALONG WITH SPECIFICATIONS, VA STANDARDS AND MANUFACTURER'S
RECOMMENDATIONS.
9. CONTRACTOR TO FIRESTOP AND SEAL PIPING PENETRATIONS, EXISTING AND CONSTRUCTED, THROUGH WALLS AND FLOORS EQUAL TO THE RATING OF WALLS AND FLOORS. THE CONTRACTOR SHALL ENSURE ALL PENETRATIONS, FOUND TO EXIST, OR CONSTRUCTED DURING THE PROJECT, HAVE FIRE STOPPING PLACED AND
PENETRATIONS ARE SEALED PRIOR TO CLAIMING ALL WORK IS COMPLETED.
10. TEST PLUMBING SYSTEM IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND NATIONAL CODES AND APPLICABLE VA STANDARDS.
11. COORDINATE PLUMBING PIPING WITH WORK OF OTHER DISCIPLINES.
12. COORDINATE PLUMBING WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION. COORDINATE ROUTING OF PIPING WITH EXISTING CONDITIONS.
13. PROVIDE ALL NECESSARY OFFSETS, TEES, ELBOWS, ETC. FOR A COMPLETE AND COORDINATED WORKING PLUMBING SYSTEM. DRAWING PLANS, SCHEMATICS, AND
DIAGRAMS INDICATE GENERAL LOCATION AND ARRANGEMENT OF PIPING SYSTEMS.
14. CONTRACTOR SHALL COORDINATE ANY PLUMBING SYSTEM REQUIRED SHUTDOWN WITH THE COR/VA 3 WEEKS IN ADVANCE.
15. PATCH, PAINT AND CLEAN SURFACES SUSTAINING DAMAGE ASSOCIATED WITH PLUMBING WORK OF THIS CONTRACT, UNLESS NOTED OTHERWISE.
16. INSTALL ESCUTCHEONS IN ALL PLACES WHERE PIPING PENETRATES A WALL IN AN EXPOSED LOCATION.
17. DO NOT INSTALL PIPES ABOVE TELECOM OR ELECTRICAL EQUIPMENT.
PLUMBING GENERAL NOTES
DCWR
DHW
PIPING SYSTEM
NG NATURAL GAS
ST STORM
PD PUMP DISCHARGE
OFD OVERFLOW STORM DRAIN
GW GREASE WASTE
OW OIL WASTE
SAN SANITARY WASTE
CD CONDENSATE DRAIN
CA COMPRESSED AIR
AW ACID WASTE
N2 NITROGEN
N2O NITROUS OXIDE
MA MEDICAL AIR
O2 OXYGEN
WAGD WASTE ANESTHETIC GAS DISPOSAL
VAC VACUUM
V SANITARY VENT
OV OIL VENT
AV ACID VENT
NPCW NONPOTABLE COLD WATER
DI DE-IONIZED WATER
SCW SOFTENED COLD WATER
DCW DOMESTIC COLD WATER
RO REVERSE OSMOSIS WATER
DOMESTIC CW RECIRCULATION
DOMESTIC HOT WATER
CO2 CARBON DIOXIDE
DHW 140 DOMESTIC HOT WATER (OTHER TEMP)
PG PROPANE GAS
DHWR DOMESTIC HW RECIRCULATION
NG
ST
PD
OFD
GW
OW
SAN
CD
CA
AW
N2
N2O
MA
O2
WAGD
VAC
CO2
PG
V
OV
AV
HW 140
SCW
NPCW
DI
RO
PLUMBING SYMBOLS
3-WAY CONTROL VALVE
ANGLE GATE VALVE
ANGLE GLOBE VALVE
BALL VALVE
BUTTERFLY VALVE
CHECK VALVE
CONTROL VALVE
GATE VALVE
GLOBE VALVE
SAFETY RELIEF VALVE
TWO POSITION CONTROL VALVE
BACKFLOW PREVENTER
ECCENTRIC REDUCER
CONCENTRIC REDUCER
FLOW ARROW
HOSE BIBB / SILLCOCK
PLUG VALVE
PRESSURE REDUCING VALVE (WATER)
PRESSURE REGULATOR (GAS)
PIPE ANCHOR
PIPE GUIDES
WALL CLEANOUT
SUSPENDED CLEANOUT
WCO
WYE STRAINER
WYE STRAINER W/DRAIN VALVE
FLOOR DRAIN - ROUND OR SQUARE
FLOOR CLEANOUT - ROUND OR SQUARE
PIPE CAP
PIPE TURNING DOWN
PIPE TURNING UP
TEE UP
TEE DOWN
DROP AND RUN
DROP AND TURN
TEE OFF TOP
TEE OFF BOTTOM
CROSS AND RISER
PLAN 90° ELBOW
PIPE TEE
PIPE UNION
FLEXIBLE PIPE CONNECTOR
WATER METER
PUMP
AUTOMATIC AIR VENT
PRESSURE SWITCH
PRESSURE GAUGE
THERMOMETER
FLOW SWITCH
TEMPERATURE SWITCH
OR
OR
CO
PIPE SLOPE ARROW
AV
F
P
T
M
CIRCUIT SETTER
PLUMBING SYMBOLS
EXISTING
NEW WORK KEYNOTE
DEMOLITION KEYNOTE
NEW BOLD TEXT INDICATES NEW ITEM
ITALICIZED TEXT INDICATES EXISTING ITEM
DETAIL OR SECTION MARK
SHOWN ON DRAWING
DETAIL MODULE NUMBER
CONNECT TO EXISTING
LIMIT OF DEMOLITION
EQUIPMENT TAG
ANNOTATION SYMBOLS
##-X-#
P-###
P-### NEW FIXTURE: BOLD UNDERLINED TEXT
EXISTING FIXTURE: ITALICIZED TEXT
RISER MARK
RISER NUMBER
RISER SYSTEM
XXX
Engineers Architects th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing # of
VA Health Care System Approval:
Revision: Date:
ARCHITECT/ENGINEER:
JOHN COCHRAN DIVISION
915 NORTH GRAND BLVD - ST. LOUIS, MO 63106
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.
FULLY SPRINKLERED
C R e v it p ro je c ts
\M P
F
-1
S T
L -J
C -E
H R
M
G e n e ra l_ tb u d a i.
rv t
/2
/2
:0 :5
P
M
21-124 PLUMBING SYMBOLS,
ABBREVIATIONS AND NOTES
EHRM INFRASTRUCTURE UPGRADES 657-21-700JC
BID DOCUMENTS
SMHNOVEMBER 28, 2022 RBK
2 43
00-M-002
FLUSHING CONNECTION
FEED OR CROSS MAIN.
TYPICAL TEE WITH
CROSS MAIN PITCH
TOWARDS FEED MAIN.
NOTE: INSTALL FLUSHING
CONNECTION AT END OF
CROSS MAINS.
2" NIPPLE 4" LONG
WITH CAP.
MECHANICAL TEE
NEW PIPING
MECHANICAL TEE
SCREWED END
STEEL BEAM
RETAINING STRAP
C-CLAMP
THREADED HANGER ROD
ADJUSTABLE RING HANGER
NOTE:
HANGING DETAILS SHOWN ARE SUBJECT TO REQUIREMENTS OF SEISMIC DESIGN.
EXPANSION ANCHOR HILT QUIK
BOLT TZ OR APPROVED EQUAL.
EXPANSION ANCHOR SHALL BE
QUALIFIED FOR USE IN CRACKED
CONCRETE PER ACI 355.2
EXISTING CONCRETE SLAB
AUTO. SPRINKLER PIPE
SET SCREW
SURGE RESTRAINER
1" X ARMOVER
1" 90 EL
1" X DROP
DROP NIPPLE
1" x 1/2" R.C. REDUCER
NOTE:
1. ALL SPRINKLERS SHALL BE FM APPROVED QUICK RESPONSE.
2. ALL EXPOSED PIPING SHALL BE PAINTED RED.
SUSPENDED CEILING
HANGERS SHALL
BE PROVIDED AS
REQUIRED BY
NFPA 13 TYPICAL
1" x 2" NIPPLE
BRANCH LINE
PENDENT SPRINKLER HEAD
DUCTWORK OR OTHER
OBSTRUCTION OVER
48" IN WIDTH.
UPRIGHT HEAD
SPRINKLER BRANCH LINE
ALL EXPOSED
SPRINKLER PIPING
SHALL BE PAINTED RED.
UPRIGHT HEAD.
PROVIDE GUARD.
NOTE:
1. PROVIDE SPRINKLER ABOVE AND BELOW DUCT OR OTHER OBSTRUCTION OVER 48" IN WIDTH.
2. COORDINATE SPRINKLER PIPE ROUTING AND LOCATION WITH COR AND ALL PARTIES INVOLVED WITH
INSTALLATION OF THE OBSTRUCTION.
3. PROVIDE PIPE SUPPORTS THAT COMPLY WITH NFPA 13 REQUIREMENTS. INCLUDE COST OF ADDITIONAL
SUPPORTS AS REQUIRED.
4. ATTACH PIPE SUPPORTS TO BUILDING STRUCTURE OR PROVIDE SUPPLEMENTAL STEEL ANCHOR POINTS. DO NOT ATTACH PIPE SUPPORTS TO DUCTWORK, PIPES, CONDUIT, OR EXISTING HANGER RODS FOR OTHER
EQUIPMENT.
INSTALL INSULATION AFTER
CAULKING SLEEVE, SEAL
ANNULAR SPACE.
FIRE RATED WALL AND OR SLAB.
STEEL PIPE SLEEVE TERMINATE
SLEEVE FLUSH WITH FINISHED
SURFACE.
UL-LISTED FIRESTOPPING
FINISHED ESCUTCHEON PLATE
FLUSH AGAINST WALL AND OF
SIZE TO COMPLETELY COVER
OPENING.
APPROVED TYPE FIRE SAFE &
SMOKE TIGHT CAULKING SEALER
BETWEEN BARE PIPE AND SLEEVE.
NOTE:
MINIMUM SIZE OF OPENINGS AROUND SPRINKLER PIPE PENETRATIONS OF CONCRETE OR CMU WALLS
SHALL BE IN ACCORDANCE WITH NFPA 13 SEISMIC REQUIREMENTS.
NOTES:
1. ALL EXPOSED PIPING SHALL BE PAINTED RED.
2. PROVIDE GUARDS ON UPRIGHT SPRINKLERS UNLESS OTHERWISE NOTED.
THREADED
HANGER ROD
SURGE
RESTRAINER
ADJUSTABLE
RING HANGER
BRANCHLINE
AUTO. SPRINKLER FEED
UPRIGHT AUTOMATIC
SPRINKLER, FM APPROVED,
QUICK RESPONSE
REDUCER
RISER NIPPLE
REDUCING TEE
LISTED WIRE GUARD
(RED COLOR)
1. LOCATIONS SHOWN FOR EXISTING FIRE PROTECTION PIPE AND EQUIPMENT ARE APPROXIMATE. FIELD VERIFY THE EXACT LOCATIONS OF EXISTING FIRE PROTECTION LINES AND EQUIPMENT INCLUDING RISERS AND VALVES PRIOR
TO START OF WORK.
2. COORDINATE WITH COR FOR ANY SHUTDOWNS OR PLANNED INTERRUPTIONS OF THE FIRE PROTECTION SERVICE.
GIVE THE COR THREE (3) DAYS NOTICE PRIOR TO PLANNED SHUTDOWN OR INTERRUPTION.
3. COORDINATE DEMOLITION OF FIRE PROTECTION PIPING WITH OTHER PIPING WHICH IS NOT TO BE REMOVED.
PROTECT OTHER PIPING WHICH IS NOT TO BE REMOVED FROM DAMAGE, DIRT, AND DEBRIS.
4. FIRE PROTECTION RELATED EQUIPMENT AND PIPING WHICH IS REMOVED FROM THE BUILDING IS TO BE TAKEN
OFFSITE AND DISPOSED OF.
FIRE SUPPRESSION DEMOLITION GENERAL NOTES
1. USE NFPA-13 (2019), CHAPTER 27, “PLANS AND CALCULATIONS” AS A GUIDELINE WHEN PREPARING SUBMITTALS FOR REVIEW. DISREGARD ONLY THOSE ITEMS NOT APPLICABLE TO THE INDIVIDUAL BUILDING SYSTEM. FIRE PROTECTION MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA-13 FOR
THE INSTALLATION OF AUTOMATIC SPRINKLER SYSTEM.
2. COMPLY WITH THE INTERNATIONAL BUILDING CODE (LATEST ADOPTED EDITION). INSTALLATION SHALL COMPLY WITH VA REQUIREMENTS. SYSTEM SHALL ALSO BE IN COMPLIANCE WITH ALL REQUIRED PLUMBING CODES.
3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS AND ROOM FINISH SCHEDULE WHICH INDICATE CEILING HEIGHTS. COORDINATE WITH ARCHITECT'S REFLECTED CEILING PLAN FOR LOCATION OF SPRINKLER HEADS IN AREAS WITH CEILINGS. LOCATE HEADS IN AREAS WITHOUT CEILINGS AS REQUIRED BY NFPA AND VA
REQUIREMENTS FOR THE APPROPRIATE HAZARD CLASSIFICATION.
4. THIS FACILITY IS FULLY SPRINKLERED. FIRE SUPPRESSION SYSTEM SHALL BE WET PIPE TYPE SYSTEM WITH COMPLETE SPRINKLER PROTECTION UNLESS NOTED OTHERWISE. SYSTEM TO BE DESIGNED AS REQUIRED BY NFPA
AND VA REQUIREMENTS FOR THE APPROPRIATE HAZARD CLASSIFICATION.
5. SPRINKLER HEAD LAYOUTS INDICATED ARE BASED ON OCCUPANCY HAZARD CLASSIFICATIONS OUTLINED IN NFPA-13
AND VA STANDARDS.
6. PROVIDE ACTUAL NUMBER OF HEADS, REQUIRED SPACING AND PIPE ROUTING AS REQUIRED FOR CLEARANCE WITH STRUCTURAL CONDITIONS AND OTHER TRADES TO PROVIDE A COMPLETE AND OPERABLE SYSTEM IN ACCORDANCE
WITH NFPA AND VA REQUIREMENTS.
7. FIRE PROTECTION CONTRACTOR SHALL OBTAIN FLOW TEST DATA INDICATING THE WATER FLOW, STATIC PRESSURE AVAILABLE WITH NO FLOW, AND RESIDUAL PRESSURE AT FULL FLOW TO THE FACILITY. SUBMIT PLANS RELATED TO
A MINIMUM OF 1 REMOTE AREA FOR REVIEW.
8. PIPING IS SHOWN IN SCHEMATIC FORM TO INDICATE APPROXIMATE ARRANGEMENT OF EQUIPMENT AND PIPING.
SPRINKLER CONTRACTOR SHALL DESIGN THE SYSTEM AND ROUTE PIPING AS REQUIRED FOR CONFORMANCE WITH ACTUAL BUILDING CONDITIONS AND NFPA REQUIREMENTS. COORDINATE SPRINKLER WORK WITH ALL OTHER
TRADES TO AVOID CONFLICT.
9. SUPPORT NEW PIPING AND EQUIPMENT FROM STRUCTURE. PROVIDE ALL SUPPLEMENTAL STEEL TO SPAN BETWEEN PRIMARY BUILDING STRUCTURAL MEMBERS. DESIGN SUPPLEMENTAL STEEL AND SUPPORTS INCLUDING REACTION
LOADS AT PRIMARY BUILDING STRUCTURAL MEMBERS.
10. PROVIDE SPRINKLER HEADS IN CONCEALED LOCATIONS IN ACCORDANCE WITH NFPA REQUIREMENTS.
11. CLEAN ENTIRE WORK AREA OF ALL DUST, DIRT, AND OTHER DEBRIS. MAINTAIN WORK AREA IN CLEAN CONDITION.
12. PROVIDE ALL LABOR, MATERIALS, TOOLS, EQUIPMENT, ETC. REQUIRED FOR COMPLETE AND FUNCTIONAL SYSTEM
AS SPECIFIED AND INDICATED ON THE DRAWINGS.
13. SUBMIT ONE COMPLETE SET OF AUTOMATIC SPRINKLER SYSTEM DRAWINGS, CURRENT WATER FLOW TEST, AND THE EQUIPMENT DATA BROCHURES PREPARED BY OR UNDER THE SUPERVISION OF, AND SEALED BY A
PROFESSIONAL ENGINEER.
14. REPAIR OR REPLACE NON-CONFORMING AND INADEQUATE WORK AT NO ADDITIONAL COST TO THE VA.
15. PROVIDE FIRE STOPS / SEALANT AT ALL PIPE PENETRATIONS THROUGHOUT FIRE RATED WALLS. REVIEW ARCHITECTURAL PLANS PRIOR TO BIDDING AND INDICATE PENETRATIONS ON SPRINKLER LAYOUT SUBMITTAL.
16. FURNISH AND INSTALL ARMOVER SUPPORTS FOR ALL END OF LINE BRANCH LINES IN ACCORDANCE WITH NFPA-13.
17. ALL DROPS TO SPRINKLER HEADS SHALL TEE / ELBOW OFF TOP OF BRANCH PIPE, EXCEPT WHERE STRUCTURAL, ARCHITECTURAL OR MECHANICAL EQUIPMENT CONDITIONS PRECLUDE CONNECTION AT TOP OF PIPE.
18. SPRINKLER HEADS SHALL BE IN A SYMMETRICAL PATTERN, NOT NECESSARILY IN THE CENTER OF ROOMS OR
CORRIDORS. LOCATE CENTERED IN CEILING TILE WHERE POSSIBLE.
19. CONTRACTOR SHALL ASSESS THE ADEQUACY OF THE EXISTING WATER SUPPLY. PERFORM WATER SUPPLY FLOW
TESTING OF FIRE HYDRANTS AND/OR FIRE PUMP IF NECESSARY.
FIRE SUPPRESSION GENERAL NOTES
NOTE: NOT ALL SYMBOLS MAY BE USED ON THIS PROJECT
SEMI-RECESSED SPRINKLER HEAD
UPRIGHT SPRINKLER HEAD
FIRE LINEFL
CONCEALED SPRINKLER HEAD
PENDANT SPRINKLER HEAD
SIDEWALL SPRINKLER HEAD
FIRE DEPARTMENT CONNECTION (FDC)
FIRE DRAINDRAIN
POINT OF NEW CONNECTION
LIMIT OF DEMOLITION
NEW WORK KEYNOTE
DEMOLITION KEYNOTE
FIRE PROTECTION CONTRACTORFPC
TAMPER SWITCH
FLOW SWITCH
CHECK VALVE
GATE VALVE
EXTERIOR ALARM GONG (WATER ACTIVATED)
TEST AND DRAIN ASSEMBLY
BACKFLOW PREVENTER
T&D
TS
FS
ORDINARY HAZARD
GROUP 1 OCCUPANCY
DETAIL OR SECTION MARK
SHOWN ON DRAWING
DETAIL MODULE NUMBER
ORDINARY HAZARD
GROUP 2 OCCUPANCY
LIGHT HAZARD
FIRE SUPPRESSION SYMBOLS AND ABBREVIATIONS
1. CONTRACTOR SHALL COMPLY WITH THE VA'S INFECTION CONTROL RISK ASSESSMENT REQUIREMENTS AND
WRITTEN DUST CONTROL PLAN.
2. EXISTING AIR QUALITY REQUIREMENTS AND OTHER UTILITY REQUIREMENTS FOR OCCUPIED AREAS SHALL BE
MAINTAINED.
3. RENOVATION AREAS SHALL BE ISOLATED FROM OCCUPIED AREAS DURING CONSTRUCTION USING AIRTIGHT BARRIERS. PROVIDE EXHAUST AIRFLOW IN A MANNER THAT SHALL BE SUFFICIENT TO MAINTAIN NEGATIVE AIR PRESSURE IN THE CONSTRUCTION ZONE. COORDINATE TEMPORARY BARRIERS WITH INTERIM LIFE SAFETY
MEASURES.
4. FIRE PROTECTION SYSTEM REVISIONS SHALL BE PROPERLY PERFORMED TO LIMIT WATERBORNE OPPORTUNISTIC
PATHOGENS.
5. CRUCIAL VENTILATION SPECIFICATIONS FOR AIR BALANCE AND FILTRATION SHALL BE VERIFIED BEFORE OWNER'S
ACCEPTANCE.
INFECTION CONTROL MEASURES
1. DURING THE TIME THAT THE FIRE PROTECTION RENOVATION WORK IS BEING PERFORMED, AND THE FIRE PROTECTION SYSTEM IS OUT OF COMMISSION, CONTRACTOR SHALL HAVE SUFFICIENT PERSONNEL ONSITE TO KEEP A “FIRE WATCH” ON THE FACILITY IN ACCORDANCE WITH VA REQUIREMENTS. AN OUT OF SERVICE TAG MUST BE PLACED AT THE FIRE ALARM PANEL AND THE FIRE DEPARTMENT CONNECTION. REFER TO INTERNATIONAL FIRE
CODE CHAPTER 9, SECTION 901.7.
2. FIRE WATCH PERSONNEL ARE TO KEEP WATCH FOR FIRES IN THE GENERAL AREA OF PERFORMANCE, THE
PERSONS PERFORMING THE FIRE WATCH ARE NOT PERMITTED TO PERFORM ANY OTHER DUTIES.
3. FIRE WATCH PERSONNEL ARE TO HAVE FIRE EXTINGUISHING EQUIPMENT READILY AVAILABLE AND TO BE TRAINED
IN ITS USE.
4. THE QUANTITY OF PERSONNEL INVOLVED IN THE FIRE WATCH IS TO BE ADEQUATE SUCH THAT EACH FLOOR, LEVEL, AND ROOM OF THE FIRE AREA IS COVERED.
BUILDING AND OCCUPANT SAFETY - INTERRUPTION OF FIRE
PROTECTION SERVICE
THE FIRE PROTECTION DRAWING IS DESIGNED TO BE IN CONFORMANCE WITH NFPA
13. IT IS A PERFORMANCE BASED DRAWING INDICATING THE EXTENT OF FIRE
PROTECTION WORK FOR THE AREA THAT THIS DRAWING REPRESENTS. THIS
DRAWING IS “FOR INFORMATION ONLY”, AS A REFERENCE FOR THE FIRE
PROTECTION CONTRACTOR TO BASE THE DESIGN OF THE FIRE PROTECTION
SYSTEM ON. THE CONTRACTOR SHALL VERIFY THE EXACT CONDITIONS THAT THIS
DRAWING REPRESENTS, INCLUDING ANY PERCEIVED CONCEALED SPACES, AND THE
BUILDING TYPE AND CONSTRUCTION AS OUTLINED IN THE INTERNATIONAL BUILDING
CODE, PRIOR TO THE START OF WORK. REFER TO THE INTERNATIONAL BUILDING
CODE, NFPA 13, AND THE PROJECT SPECIFICATIONS FOR OTHER FIRE PROTECTION
REQUIREMENTS.
Engineers Architects th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing # of
VA Health Care System Approval:
Revision: Date:
ARCHITECT/ENGINEER:
JOHN COCHRAN DIVISION
915 NORTH GRAND BLVD - ST. LOUIS, MO 63106
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.
FULLY SPRINKLERED
C R e v it p ro je c ts
\M P
F
-1
S T
L -J
C -E
H R
M
G e n e ra l_ tb u d a i.
rv t
/2
/2
:1 :0
P
M
21-124 FIRE SUPPRESSION SYMBOLS,
ABBREVIATIONS AND NOTES
EHRM INFRASTRUCTURE UPGRADES 657-21-700JC
BID DOCUMENTS
SMHNOVEMBER 28, 2022 RBK
3 43
00-M-003
Scale: No Scale
MECHANICAL TEE AND FLUSHING CONNECTION DETAIL
Scale: No Scale
PIPE HANGER SUPPORT DETAIL
Scale: No Scale
SEMI-RECESSED PENDENT SPRINKLER DETAIL
Scale: No Scale
SPRINKLER ABOVE AND BELOW DUCT DETAIL
Scale: No Scale
SPRINKLER PIPE SLEEVE THRU FIRE RATED WALL DETAIL
Scale: No Scale
UPRIGHT AUTOMATIC SPRINKLER WITH GUARD DETAIL
S S
S S
S S
S S
S S
S S
S S
S SS S S
S S
S S
SS SSSSSS
S S
S
SS S
S S
S S
S S
S S
SS
S S
S
S S
S S
S S
SS
S S
S S
S
SS SSS
S S
S S
S S
S S
S S
S S
S S
S S
SS SSSSSS
S
SSS S
S
SSS SS
S S
S S
SS SSS
SSSS
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S
S SS
69 SF
SPECIMEN
A034A
568 SF
AUTOPSY
A034
118 SF
MECH
DOCK
A032
103 SF
TOILET -
LOCKER
A033
5 SF
CLOSET
A034B
67 SF
Room A036A
5 SF
CLOSET
A034C
16 SF
CLOSET
A035A
172 SF
WALK-IN
REF
A035
150 SF
VIEWING
RM.
A036
134 SF
BATTERY
CHARGING
A037
62 SF
MECH
A038
233 SF
CORRIDOR
H006
428 SF
CORRIDOR
H005
5 SF
ELEC
A001K
99 SF
A039
70 SF
WASH RM.
STORAGE
A029A
419 SF
REF
STORAGE
A028
27 SF
CLOSET
A028B
316 SF
WASH RM.
A029
321 SF
MECH
A028A
172 SF
STAIR 05
S005
141 SF
EQUIP.
STORAGE
A031
224 SF
GAS
STORAGE
A031B
129 SF
CHEMICAL
STORAGE
A031A
92 SF
VAULT
A001F
55 SF
VAULT
A001E
652 SF
SUPPLIES
A001I
577 SF
CORRIDOR
H004
461 SF
FOOD/ BEV
STORAGE
B022
126 SF
VESTIBULE
H010A
368 SF
EMS
STORAGE
A023
291 SF
VOL
SERVICE
STORAGE
A027
414 SF
EMS
STORAGE
A023A
363 SF
SERVICE
ELEVATOR
LOBBY
H007
129 SF
VESTIBULE
B022C
373 SF
FOOD/ BEV
WALK-IN
REF.
B022A
79 SF
STORAGE
A021
211 SF
STORAGE
A021A
127 SF
SILVER
RECOV.
A022
73 SF
EMS
A024
138 SF
OFFICE
A025
68 SF
OFFICE
489 SF
CORRIDOR
H009
156 SF
CORRIDOR
H010
354 SF
MECH. RM.
A002A
2474 SF
MECH. RM.
A002D
158 SF
TOILET,
MALE
A015
291 SF
MAIL RM.
A014
105 SF
STAIR 02
S002
4 SF
F.E.
CLOSET
H008A
15 SF
ELEC
A016A
553 SF
CORRIDOR
H003
269 SF
WAITING
RM.
A007
98 SF
OFFICE
A007A
97 SF
EXAM
A007B 111 SF
EXAM
A007C
96 SF
OFFICE
A007D
76 SF
CONTROL
A007E
360 SF
SIMULATOR
RM.
A007F
81 SF
OI&T
141 SF
RECEPTION
A007L
58 SF
TOILET
B007K
237 SF
OFFICE
A007G
430 SF
CORRIDOR
H002
117 SF
LOCKER
A007H
31 SF
LOCKER
A007I
45 SF
TOILET
A007J
170 SF
WORK
AREA
A008C
114 SF
MAZE
A008A
365 SF
THERAPY
ROOM 1
A008B
236 SF
CONTROL
AREA
A008
246 SF
CONTROL
A009D
633 SF
LINEAR
ACCELERATOR
A009B
146 SF
MAZE
A009A
127 SF
CORRIDOR
H001
150 SF
VESTIBULE
A009
190 SF
MOLD SHOP
A009E
1452 SF
MECH. RM.
A009C
5 SF
ELEC
A003A
91 SF
TOILET
A011J 307 SF
OUT-PATIENT
WAITING
A011
92 SF
OFFICE
A011A
148 SF
OFFICE
A010A
94 SF
PATIENT
DRESSING/
TOILET
A011I
168 SF
CORRIDOR
A011B
70 SF
PATIENT
INJECTION
A011H
114 SF
CORRIDOR
H034
150 SF
STORAGE
A012
91 SF
LABORATORY
A011G
132 SF
CONTROL
RM.
A011C
433 SF
PET/ CT
EXAM
A011D76 SF
EXAM
A011F
159 SF
MECH
A011E
211 SF
WORK RM.
A010
1860 SF
ELEC. RM.
A020
636 SF
CONFERENCE
RM.
B002K
8 SF
ELEC
B002L
196 SF
STAIR 12
S012
18 SF
ELEC RM.
B002F
27 SF
OI&T
B002G
516 SF
ELEC. RM.
A020A
640 SF
MECH. RM.
B002E
35 SF
UTILITY
SERVICE
B002H
332 SF
CORRIDOR
H034B
180 SF
OFFICE
B002C
525 SF
MECH
B002I
43 SF
STAIR 11
S011
19 SF
STORAGE
B004
3516 SF
CLEAN
MEDICAL
SUPPLY
B002
362 SF
OFFICE
B005
153 SF
OFFICE
99 SF
OFFICE
DB09
115 SF
OFFICE
DB08
118 SF
OFFICE
DB07
84 SF
OFFICE
DB06
86 SF
OFFICE
DB05
98 SF
OFFICE
DB04
155 SF
OFFICE
DB03
118 SF
RECEPTION
DB02 65 SF
VESTIBULE
DB01
74 SF
ELEC
CB27
69 SF
ELEC
CB28
157 SF
STAIR 10
S010
52 SF
STORAGE
DB16
52 SF
WORK RM.
DB10
137 SF
OFFICE
DB15A
137 SF
TR
DB15B
64 SF
MECH
DB14
183 SF
STORAGE
DB13
15 SF
OI&T
DB14A
31 SF
TOILET
DB12
31 SF
TOILET
DB11
102 SF
CORRIDOR
H029
95 SF
CORRIDOR
H027
273 SF
CORRIDOR
H028
179 SF
WAITING
RM.
H026
867 SF
CORRIDOR
H024
41 SF
MECH. RM.
CB29A
144 SF
TOILET,
MALE
DB17
76 SF
SOUND
BOOTH
DB22B
122 SF
EXAM
DB23
67 SF
SOUND
BOOTH
DB22A 120 SF
LOCKER
DB17A
115 SF
FEMALE
DB18
393 SF
SOUND
BOOTH
DB22
231 SF
CORRDOR
H032
161 SF
CORRIDOR
H030
37 SF
STORAGE
DB18A
207 SF
MANUAL
WASH
CB30
110 SF
CART WASH
CB16B
136 SF
DETERGENT
& WATER
TREATMENT
CB10
106 SF
ANTE RM.
CB11
86 SF
ANTE RM.
CB12
99 SF
LOCKER
FEMALE
CB1390 SF
LOCKER
MALE
CB14
40 SF
HAC
CB15B
96 SF
Room
CB17
241 SF
SCOPE
PROCESSING
CB17A
135 SF
SCOPE
STORAGE
CB18
93 SF
SHOWER,
FEMALE
CB15A
277 SF
ANTE RM.
CB19
142 SF
ANTE RM.
CB20
158 SF
STAIR 07
S007
97 SF
SHOWER,
FEMALE
CB21A
89 SF
SHOWER
MALE
CB22A
71 SF
HAC
CB25
183 SF
OFFICE
CB23 92 SF
LOCKER
MALE
CB22
94 SF
LOCKER
FEMALE
CB21
58 SF
ETO
CB26A
80 SF
ETO
CB26B
1102 SF
CASE CART
STORAGE
CB29
3445 SF
SURGICAL
STERILIZER
STORAGE
CB24
1919 SF
PREP/
STERILIZATION
CB26
20 SF
PUMP RM.
CB16A
10 SF
OI&T
1312 SF
DECONTAMINATION
CB16
110 SF
OFFICE
DB24
125 SF
OFFICE
DB25
125 SF
OFFICE
DB26
120 SF
OFFICE
DB27
121 SF
CORRIDOR
H031
119 SF
CORRIDOR
H033
192 SF
CORRIDOR
37 SF
HAC
DB28
299 SF
WAITING
RM.
DB32
121 SF
OFFICE
DB29
138 SF
EXAM
DB30
134 SF
EXAM
DB20
92 SF
EXAM
DB19
116 SF
OFFICE
DB31
1140 SF
MECH. RM.
DB33
123 SF
OFFICE
CB09
169 SF
STAFF
CB07
31 SF
ELEC
CB06
58 SF
OI&T
CB05
139 SF
OFFICE
CB08
192 SF
BREAK RM.
CB04
147 SF
CORRIDOR
H021
210 SF
CORRIDOR
H022
85 SF
STORAGE
CB01A
337 SF
CORRIDOR
H020
112 SF
CORRIDOR
H022A
150 SF
STAIR 06
S006
100 SF
Room
CB03B
190 SF
MECH. RM.
CB02A
1164 SF
MECH. RM.
CB02
495 SF
GENERATOR
CB03A
2341 SF
MECH. RM.
CB03
278 SF
CORRIDOR
H023
134 SF
BREAK
ROOM
B006
155 SF
BIOMED
SHOP
CB31
90 SF
OFFICE
CB32
75 SF
OFFICE
CB33
93 SF
TECH
CB34
371 SF
BIOMED
SHOP
CB36
1104 SF
EQUIPMENT
STORAGE
CB35
928 SF
ELEVATOR
LOBBY
H015
220 SF
CONFERENCE
RM.
B007
156 SF
CORRIDOR
H016
346 SF
ELEVATOR
LOBBY
H014
203 SF
STAIR 03
S003
288 SF
OFFICE
B011
234 SF
OFFICE
B010
15 SF
OI&T
B003A
69 SF
LAUNDRY
B003
18 SF
ELEC
B012A
5 SF
F.E.
CLOSET
H011A
134 SF
OFFICE
B008
137 SF
LOCKER
B001
105 SF
TOILET,
FEMALE
B001A
18 SF
OI&T
A017A
29 SF
HAC
A0177 SF
F.E.
CLOSET
B682
188 SF
STAIR 01
S001
146 SF
OFFICE
A019
12 SF
CLOSET
H008B
839 SF
MAIN
ELEVATOR
LOBBY
H008
108 SF
FOOD/ BEV.
WALK-IN
FREEZE
B022B
190 SF
WAREHOUSE
B021D
602 SF
WAREHOUSE
B021A
1084 SF
MECH.
SPACE
B021C
1430 SF
CORRIDOR
H011
110 SF
LIGHT RM.
B020B
118 SF
TOILET
B013A
61 SF
LOCKER
B013
344 SF
MACHINE
SHOP
B014
78 SF
PAINT
STORAGE
B015A
145 SF
PLASTER
SHOP
B016C
399 SF
PAINT SHOP
B015
76 SF
OFFICE
B016B
86 SF
CARPENTER
SHOP
STORAGE
B016A
120 SF
OFFICE
B020A
498 SF
ELEC SHOP
B020
86 SF
OFFICE
B019A
227 SF
PLUMB.
SHOP
B019
188 SF
STAIR 04
S004
294 SF
PLUMB.
SHOP
B019B
81 SF
HVAC SHOP
B17C
829 SF
CORRIDOR
H012
65 SF
OFFICE
B017A
204 SF
CORRIDOR
H013
611 SF
CARPENTER
SHOP
B016
279 SF
HVAC SHOP
B017B
97 SF
STERILIZER
RECESS
CB26C
509 SF
DECONTAMINATION
CB15
44 SF
MECH
B004A
76 SF
ELEV 3
E3
80 SF
ELEV 8
E8
2 SF
CLOSET
H005A
849 SF
TELEPHONE
SWITCHGEAR
A001
721 SF
SERVER
RM.
A001A
60 SF
PHONE
A001L
279 SF
PATIENT
CLOTHING
A002
261 SF
OFFICE /
STORAGE
A016
65 SF
ELEV 10
E10
Redundant Room
TELEPHONE
SWITCHGEAR
A001C
Redundant Room
OFFICE
A001B
101 SF
WAREHOUSE
B021E
11 SF
CHASE
CH-DB-1
30 SF
CHASE
CH-CB-2
29 SF
CHASE
CH-CB-4
33 SF
CHASE
CH-CB-5
8 SF
CHASE
CH-CB-6
43 SF
CHASE
CH-CB-7
12 SF
CHASE
CH-CB-8
93 SF
CHASE
CH-CB-9
7 SF
CHASE
CH-CB-10
20 SF
CHASE
CH-CB-11
11 SF
CHASE
CH-B-12
30 SF
CHASE
CH-B-13
21 SF
CHASE
CH-A-2
10 SF
CHASE
CH-A-3
36 SF
CHASE
CH-A-4
33 SF
CHASE
CH-A-5
13 SF
CHASE
CH-A-6
15 SF
CHASE
CH-A-7
16 SF
CHASE
CH-A-8
19 SF
CHASE
CH-A-9
13 SF
CHASE
CH-A-10
10 SF
CHASE
CH-A-11
27 SF
CHASE
CH-CB-12
102 SF
CHASE
CH-A-1
160 SF
STAIR 7
226 SF
STAIR 08
S308
211 SF
STAIR 09
S309
79 SF
ELEV 1
E1
79 SF
ELEV 2
E2
76 SF
ELEV 4
E4
98 SF
ELEV 5
E5
98 SF
ELEV 6
E6
80 SF
ELEV 7
E7
80 SF
ELEV 9
E9
285 SF
STORAGE
A001G
261 SF
SUPERVISOR
A001H
66 SF
VAULT
A001D
863 SF
CART
HOLDING
A001J
171 SF
EMS
A001M
190 SF
BREAK
AREA/
LOCKERS
B002B
355 SF
OFFICE
102 SF
CORRIDOR
H034A
168 SF
RECEIVING
B021B
185 SF
TELECOM
T001
01-MP402
01-MP401
01-MP403
2" CHR
2" CHS
3" CHS3" CHR
10" CHS
10" CHR
123 SF
TR
B009
3/4" D
# KEY NOTES:
Engineers Architects th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing # of
VA Health Care System Approval:
Revision: Date:
ARCHITECT/ENGINEER:
JOHN COCHRAN DIVISION
915 NORTH GRAND BLVD - ST. LOUIS, MO 63106
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.
FULLY SPRINKLERED
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREAS S S S
C R e v it p ro je c ts
\A M
E P
F
-J
C
-0 tb u d a i.
rv t
/2
/2
:0 :3
P
M
21-124 BUILDING 1, GROUND FLOOR,
OVERALL MECHANICAL PLAN
EHRM INFRASTRUCTURE UPGRADES 657-21-700JC
BID DOCUMENTS
SMHNOVEMBER 28, 2022 RBK
4 43
01-MP100
NORTH
0 8 16 32
Scale: 1/16" = 1'-0"
BUILDING 1, GROUND FLOOR, OVERALL MECHANICAL PLAN
N
KEY PLAN
SCALE: NO SCALE
1 1" CHS/R DOWN TO NEW FAN COIL UNIT.
2 2-1/2” CHS/R UP. SEE 01-MP101 FOR
CONTINUATION.
3 PUMP 3/4” CONDENSATE DRAIN TO SINK IN
HAC D106 ABOVE.
4 CONDENSATE DRAIN AND CHS/R PIPING UP
TO FLOORS. SEE RISER FOR PIPE SIZES.
5 1-1/2” CHS/R UP. SEE 01-MP101 FOR
CONTINUATION.
6 1” CHS/R DOWN.
7 CONNECT INTO EXISTING 6" CHS/R.
8 CONNECT INTO EXISTING 10" CHS/R.
9 FIELD COORDINATE PIPE LOCATION WITH
EXISTING PIPE & DUCTWORK CONDITIONS.
10 PUMP 3/4” CONDENSATE DRAIN TO SINK IN
TOILET B013A.
A. SEE THE SHEET REFERENCED AT DETAILED
AREA CALLOUT FOR MECHANICAL,
PLUMBING, AND FIRE SUPPRESSION PLANS,
BOTH DEMOLITION AND NEW, IN THAT AREA.
B. COORDINATE ALL WORK WITH THE GENERAL
CONTRACTOR, OTHER TRADES AND THE COR
TO MINIMIZE DISRUPTION OF AREAS OUTSIDE
OF THE PROJECT LIMITS OF WORK.
C. ALL DEMOLISHED EQUIPMENT SHALL
BECOME THE PROPERTY OF THE
CONTRACTOR AND SHALL BE DISPOSED OF
IN ACCORDANCE WITH VAPHS
REQUIREMENTS AND ENVIRONMENTAL
REGULATIONS.
D. CONTRACTOR TO FIELD VERIFY ALL
CONDITIONS. PRESERVE EXISTING
DUCTWORK, PIPING OR EQUIPMENT THAT IS
NOT INDICATED FOR DEMOLITION OR IS
DISCOVERED IN THE DEMOLITION PROCESS.
E. UNLESS NOTED OTHERWISE, ALL DIFFUSERS
AND GRILLE RUN-OUTS ARE THE SAME SIZE
AS THE NECK/DUCT CONNECTION SIZE
SPECIFIED IN THE AIR DEVICE SCHEDULE.
F. ALL DIFFUSER AND GRILLE TAKEOFFS SHALL
INCLUDE A BALANCING DAMPER.
G. SEE ARCHITECTURAL CEILING PLAN FOR
CEILING TYPES AS WELL AS DIFFUSER AND
GRILLE PLACEMENT WITHIN THE CEILING.
H. COORDINATE ALL THERMOSTAT LOCATIONS
WITH ALL OTHER WALL MOUNTED OBJECTS
BEFORE INSTALLATION.
I. PROVIDE ISOLATION BALL VALVES FOR EACH
PIPING BRANCH. LOCATE AS CLOSE TO MAIN
AS POSSIBLE.
DN
S
SSS S
S S
S S
S SS S
SSSS S SS S
SSSS
S S
S S
S S
S S
S S
S S
S S
S SS S S S S S
S S
S
S S
S S
S S
S S
S S
SS
S S
S
S SS
S S
S S
S SS S S S S S
S
SS SS S S
S
SSS
S S
S
S SS S
SS SSSS
S
SSS S
S
SSS SS
S
SSS S
SS S
S
SSS SS
S S
S S
SS
S S
S
SS
S S
S S
S S
S S
S SS
S S
S S
S S
S S
S S
S S
S S
S S
SS SSSSSSSS
S SS S S S S S S S
S
SS SS
S S
S
S SS S
SS SS S
S
SSS S
S S
S S
S SS S
SSSS S SS S
SSSS
S S
S S
S S
S S
S S
S S
S S
S SS S S S S S
S S
S
S S
S S
S S
S S
S S
SS
S S
S
S SS
S S
S S
S SS S S S S S
S
SS SS S S
S
SSS
S S
S
S SS S
SS SSSS
S
SSS S
S
SSS SS
S
SSS S
SS S
S
SSS SS
S S
S S
SS
S S
S
SS
S S
S S
S S
S S
S SS
S S
S S
S S
S S
S S
S S
S S
S S
SS SSSSSSSS
S SS S S S S S S S
S
SS SS
S S
S
S SS S
SS SS S
121 SF
EXAM
A120
164 SF
HEMO DIAL
TREAT BAY
A162E
625 SF
CORRIDOR
H109B
117 SF
HEMO DIAL
TREAT BAY
A162F
117 SF
HEMO DIAL
TREAT BAY
A162G
119 SF
HEMO DIAL
TREAT BAY
A162H
125 SF
HEMO DIAL
TREAT BAY
A162J
115 SF
HEMO DIAL
TREAT BAY
A162A
116 SF
HEMO DIAL
TREAT BAY
A162B
113 SF
HEMO DIAL
TREAT BAY
A162C
113 SF
HEMO DIAL
TREAT BAY
A162D
115 SF
EXAM
A163A
140 SF
EXAM
A163B
46 SF
TOILET
A160
19 SF
ELEC
A161
193 SF
NURSE
STATION
A156
61 SF
NOUR.
A159
107 SF
OFFICE
A158
73 SF
MED. PREP.
A157
133 SF
PATIENT
ISO.
A164
46 SF
TOILET
A164A
45 SF
TOILET
A165A
170 SF
STAIR 05
S105
132 SF
PATIENT
ISO.
A165
260 SF
MECH. RM.
A155
56 SF
SOILED
A154
92 SF
CORRIDOR
H108
77 SF
SCALE
H108B
38 SF
HAC
A166
93 SF
EQUIPMENT
REPAIR
A167
102 SF
PERITONEAL
DIALYSIS
A168
108 SF
EXAM
A169A
105 SF
EXAM
A169B
123 SF
OFFICE
A170A
54 SF
DIETITIAN
A170C
39 SF
IV
TREATMENT
A170B
39 SF
IV
TREATMENT
A170D
37 SF
CLEAN
A154A
53 SF
TOILET
A174A
44 SF
TOILET
A173A
194 SF
CONFERENCE
RM.
A153
119 SF
OFFICE
A170F
18 SF
SUPPLY
A170E
96 SF
CORRIDOR
H109C
260 SF
CORRIDOR
H108D
89 SF
CORRIDOR
H109A
18 SF
COATS
A173B 18 SF
STORAGE
A168A
62 SF
LOCKER
RM.
A172A
69 SF
RECEPTION
A173
76 SF
DECONTAMINATION
A171
90 SF
OFFICE
A170G
227 SF
LOUNGE
A172
164 SF
WAITING
A174
265 SF
CORRIDOR
H109
1771 SF
WAITING
RM.
A100
148 SF
RECEPTION
A100A
158 SF
COFFEE
SHOP
A100B
41 SF
STORAGE
A100C
130 SF
TOILET
A101A
41 SF
VESTIBULE
A101
190 SF
TOILET
A101B
91 SF
RELEASE
OF
INFORMATION
A101C
280 SF
OPTICAL
SHOP
A101D
387 SF
CORRIDOR
H105
240 SF
NEPHROLOGY
A177
98 SF
OFFICE
A177A
103 SF
OFFICE
A177B
111 SF
OFFICE
A177C
31 SF
STORAGE
A177D
114 SF
OFFICE
A177E
10 SF
CLOSET
A177F
93 SF
OFFICE
A177G
59 SF
ALARM
PANEL
A102
87 SF
OFFICE
A103
276 SF
RECEPTION
A135
552 SF
WAITING
RM.
A134
93 SF
SCREEN
A104
93 SF
SCREEN
A105
111 SF
LEAD
NURSE
A106 101 SF
EXAM
A107
119 SF
OFFICE
A108
111 SF
OFFICE
A109
213 SF
BREAK
A110
138 SF
EXAM
A111
121 SF
EXAM
A112138 SF
EXAM
A113
119 SF
EXAM
A114
124 SF
EXAM
A115
113 SF
EXAM
A116
128 SF
TOILET
A117
25 SF
HAC
A118
9 SF
ELEC
A119
22 SF
TOILET
A110A
285 SF
CORRIDOR
H101
231 SF
CORRIDOR
H102
134 SF
EXAM
A121
142 SF
EXAM
A122
141 SF
EXAM
A123
114 SF
OPHTH.
CHIEF
RESIDENT
A124
113 SF
OPHTH.
CHIEF
RESIDENT
A125
106 SF
EXAM
A126
126 SF
LASER
TREATMENT
A127
141 SF
PROCEDURE
A128
120 SF
EXAM
A129
118 SF
EXAM
A130
119 SF
CLINICAL
MANAGER
A131
160 SF
EXAM
A132
158 SF
IMAGING
SUPPLY
A133
172 SF
OFFICE,
CHIEF
A132A
10 SF
ELEC
A131A
173 SF
STAIR 02
S102
1015 SF
CORRIDOR
H103
14 SF
ELEC
A137A
20 SF
OI&T
A136
19 SF
FIRE
ALARM
SYSTEM
A136A
229 SF
STAIR 01
S101139 SF
NEUROLOGY
CLINIC
A139191 SF
WAITING
RM.
A139F
481 SF
CORRIDOR
H123
92 SF
NURSE
STATION
A139E
161 SF
EXAM
A139D
154 SF
EXAM
A139C
161 SF
EXAM
A139G
164 SF
EXAM
A139H
172 SF
EXAM
A139J
172 SF
EXAM
A139K
140 SF
EXAM
A139B
141…